• No results found

Study on safety technology of anti-caving at a super-large section roadway with thick and fractural coal roof

N/A
N/A
Protected

Academic year: 2021

Share "Study on safety technology of anti-caving at a super-large section roadway with thick and fractural coal roof"

Copied!
9
0
0

Loading.... (view fulltext now)

Full text

(1)

Procedia Engineering 26 (2011) 545 – 553 1877-7058 © 2011 Published by Elsevier Ltd. doi:10.1016/j.proeng.2011.11.2204

Procedia

Engineering

Procedia Engineering 00 (2011) 000–000 www.elsevier.com/locate/procedia

First International Symposium on Mine Safety Science and Engineering

Study on safety technology of anti-caving at a super-large

section roadway with thick and fractural coal roof

Fulian He

a

, Boda Yang

a

, Shuaifeng Yin

a,∗

aCollege of Resources & Safety Engineering, China University of Mining & Technology (Beijing), Beijing 100083, China

, Xin Wang

a

& Chunyang Tian

a

Abstract

Numerical simulation is applied to analyze surrounding stress distribution of individual cells and the reasons are proposed why roof caving easily happens at apex angle and at the center of roadway. Furthermore, based on key factors of roof caving and mechanics derivation of neutral axis’s new position in roof beam, the superiority of prestressed truss cable and its key component--connector is thoroughly analyzed in safety management of anti-caving. Finally, according to the geometric size and abutment pressure influence of coal roadway No. 9101 in Danshuigou coal mine, prestressed truss cable combined control scheme and its corresponding parameters are designed by use of numerical simulation method and engineering analogue method, then the scheme have been put into practice on spot. The field observation results show that roof should be effectively controlled by the cable truss structure consisting of two long cables and one connector, which could prevent roof accidents fundamentally at a super-large section roadway with thick and fractural coal roof.

Keywords:prestressed truss cable; safety management of anti-caving; thick and fractural coal roof; numerical simulation

1. Introduction

Proportion of roof accidents has been increasing in coal mines with the development of mine exploitation converting to single stratum and full coal roadway in recent years. During the periods of 2006~ 2010, roof accidents have occurred 7754 times with 9009 death in all coal mines in China, which

Corresponding author: Shuaifeng Yin; Tel: +86 15210567592;

E-mail address: yinshuaifeng@126.com

Open access under CC BY-NC-ND license.

University of Wollongong. © 2011 Published by Elsevier Ltd.

Selection and/or peer-review under responsibility of China Academy of Safety Science and Technology, China University of Mining and Technology(Beijing), McGill University and

(2)

respectively occupies 54.3% and 38.0% of all contemporaneous coal mine accidents and the death ( 14267 accidents with 23712 death). Take accidents of Chinese coal mines in 2010 for example, which is shown in Fig.1, the proportion of roof accidents accounts for 56% to total accidents[1]. Hence, roof accidents have already become the restricting factor to threat life safety of miners and normal production activity of coal mines.

Other accident 7. 8%

Blasting accident 3%

Electromechanical accident 3%

Flood accident 3% Fire accident 0.2%

Gas accident 11%

Roof accident 56% Haulage accident 16%

Fig 1. Type and proportion of coal mine accidents in 2010 in China

The increase of roadway section makes roof stress and deformation enhance quadratically and cubically respectively[2~ 4]. The tensile stress concentration at the central of the roof could cause the tension failure,

while shear stress acts at the apex angle where the shear failure would appear. Considering the fractural and thick coal roof with developed joint fissures and low intensity, the roof would easily cause severe deformation, or even induce roof accidents, which makes it more difficult to manage the super-large section roadway with thick and fractural coal roof.

2. Numerical simulation analysis of roof caving types and reasons

2.1. Common types of roof caving

According to different locations of roof caving perpendicular to the length direction of roadway, the common types of roof caving in the super-large section roadway with thick and fractural coal roof can be divided into two types: caving at apex angle and at the center of roadway, as shown in Fig. 2.

Fig. 2. Roof caving at apex angle and at the center of roadway

2.2. Numerical simulation analysis of roof caving reasons

The numerical simulation software FLAC3D 3.00 is developed by ITASCA company in U.S., which is applied to simulation analysis. Parameters of simulation are set according to the mechanics experimental results of rock and coal samples, which are collected at open-off cut NO. 9101 in Danshuigou coal mine, as shown in table 1.

(3)

Table 1. Mechanics parameters of rock and coal samples collected at open-off cut NO.9101 in danshuigou coal mine Material Density (Kg/m³) Shear modulus (MPa) Bulk modulus (MPa) Cohesion (MPa) Internal fiction angle(°) Tensile strength (MPa) Medium-coarse sandstone 2600 12530 14690 8.58 30 3.53 Packsand 2630 11860 15360 14.15 31 9.10 Siltstone 2663 11310 16480 20.90 40 3.87 Sandy mudstone 2545 1385 2580 11.13 32 2.32

9# coal & 11# coal 1400 750 1630 2.52 28 0.81

Stress distribution of individual cells is gotten by choosing vertical plane as the profile which contains the midline of the roadway.

From Fig. 3, regularity of stress distribution of surrounding rock at super-large section coal roadway could be concluded from the simulation results:

Fig. 3. The stress distribution of individual cells

a) The tensile stress is concentrated at the center of roadway and main stress belongs to normal tensile stress( relative to profile); the spread range of the tensile stress perpendicular to the length direction of roadway to the both sides and the roof is small; with the distance to the top surface of the roadway increasing, the stress distribution state of individual cells transforms from tensile stress to compressive stress which means that a neutral surface made up of numerous neutral axes is existent.

b) Shear stress is concentrated at the apex angle of the roadway and its extension shape is a narrow strip along the length direction of roadway, which is the main reason why roof accidents happen easily here.

3. The superiority of prestressed truss cable system in safety management of anti-caving 3.1. The structure and superiority of prestressed truss cable

As shown in Fig. 4, the high prestressed cable truss supporting system consists of two anchor steel cables with high tensile-strength and one connector with integral wedges, which two anchoring points are located in the deep rock mass in compressive stress field on a roadway. This supporting system with the

(4)

high tension prestress can provide horizontal compressive prestress to middle roof, improve the roof stress state, strengthen mechanical properties of lower roof, and enhance its anti-deformation performance.

Compared with the conventional bolt or single cable supporting, this cable truss supporting system would have five advantages[4~ 5]:

a) It can supply active supporting force whose directions are both horizontal and vertical. As the roof deformation becomes larger, the supporting force and internal bearing stress of cable truss gradually increase too. The new type of supporting system can effectively reduce the highest tensile stress in the middle area of roadway roof, which helps to keep rock under multi-dimensional supporting state and raises both rock intensity and roof anti-deformation performance.

b) Owing to the large length and excellent anti-shear properties, truss cable can go through the highest shear stress region of roadway roof and its control area is bigger than the bolt supporting range. So the cable truss is able to control roof’s shear deformation and failure more effectively.

c) Since the cable truss system contacts with the roof along lines, its supporting influence is much larger than the one of the single cable or bolt. The roof load acting on the cable truss could be transferred continuously and higher pretension can be applied. As a result, the loose or broken roof may be kept in a good state more easily.

d) The anchor points of cable truss lie within the rock compressed the three directions, which are hardly influenced by roof separation or deformation. So it could provide reliable and stable basement for high anchoring force.

e) During roof curvature and subsidence, the anchor points above both sides move inside slightly and the bearing force increases reasonably. The lock structure is relatively difficult to be destroyed, and its supporting function keeps for more time, and then the locking structure could control the rapid roof deformation and prevent serious caving accidents.

1 2 3 4 1 2 3 4 1 2 3 4

Fig 4. Complex and active control schematic diagram of truss cable system and the force cloud chart of connector. 1 —truss cable; 2 — connector; 3 — compression area; 4 —anchoring poi nts

3.2. Anti-caving mechanism of prestressed truss cable

Using the prestressed truss cable system could prevent roof caving effectively and realize safety management of roof, which can be manifested in the following:

a) The neutral axis of surrounding rock in the anchorage zone will move down if high prestressed truss cable is applied.

For most rock material, the tensile and compressive modulus of elasticity are different[6~7]. As shown in

(5)

and the tensile modules of elasticity is E1as well as the compressive modulus of elasticity is E2.

For the bending deformation of rock beam complied with small deformation theory, according to the plate symposium, it is known that the longitudinal linear strain has a linear change along the height direction of rock beam[8]. We receive the geometric equation:

y

ε ρ

=

Based on the Hooke’s Law, the tensile stress and compressive stress on the cross section can be got:

1 1 y E σ ρ = 2 2 y E σ ρ = (1)

Assuming two distances: the location of the neutral axis z to the top and bottom edge of the cross section are h1and h2respectively. As the axial force of the cross section is zero and in static equilibrium

conditions, the synthesizing bending moment caused by normal stress in cross section is zero. There are

1 1 2 2 0, 0 x A A F = σdA+ σ dA=

(2) 1 1 2 2 , z A A M =M

σ

ydA+

σ

ydA M=

(3)

Plug formula (1) into formula (2) and formula (3), there are:

2 2 1 1 2 2 0 2 2 E b h E b h ρ ρ − + = (4) 3 3 1 1 2 2 3 3 E bh E bh M ρ + ρ = (5)

For h1+h2=h, combine with formula (4), and the location of the neutral axis can be confirmed:

2 1 1 2 1 2 1 2 h E h E E h E h E E  =  +    =  +(6)

Formula (6) is the expression of the location of the neutral axis when we ignore the influence of external force. It can be got from formula (5) that:

3 3

1 1 2 2

1 3M

E bh E bh

ρ= + (7)

Plug formula (7) into formula (1), and the expression of tensile stress and compressive stress on cross section is: 3 3 1 1 2 2 3 s s ME y E bh E bh σ = + (8)

In formula (8), the value of sis 1 when the stress locates in the tensile stress area, whereas be 2. Then we get the value of σs:

3 3 1 1 2 2 3 s 2 sin s ME y F E bh E bh mn α σ = = + (9)

(6)

So the location of the neutral axis is:

(

3 3

)

1 1 2 2 2 sin y 3 s F E bh E bh ME mn α + = (10)

In formula (9), mis the row distance of truss cable in the practical support system;nis the distance between two orifices of truss cable;Fis the tension force of truss cable;αis the included angle between the truss cable and the horizontal plane.

n E1 E2 z y h1 h2 α F F b

new location of the neutral axis

Truss cable

Connector

Fig 5. Change of the neutral axis schematic diagram at anchorage zone

As shown in formula (9), the downward dropping distance of neutral axis in anchorage zone has the relationship with the stress of the anchor truss cable: when the angle of the truss cable is constant, the higher truss cable stress is, in other words, higher y, the nearer neutral axis gets to the upper surface of the roadway, which makes bigger boundary coal and rock of roof beam in the compressive stress condition and improves the mechanical properties and the bearing behavior.

b) High prestressed truss cable can prevent roof caving at apex angle of roadway effectively.

For the reasons that truss cable has the appropriate length, high prestress and strong anti-shear property, goes through the highest shear stress region of roadway roof from the top of the rib and shares shear stress with corner bolt and roof beam, which could prevent shear failure of the roof and control roof caving at apex angle of roadway effectively.

Prestressed truss cable could provide reliable supporting force at horizontal and vertical direction, meanwhile, enhance the strength of coal and rock and the property of anti-deformation, and the downward shift of the neutral axis in anchorage zone which make coal and rock in the multidirectional compressive stress condition. The prestressed cable truss supporting system could solve problems effectively of low strength, stress concentration, delamination sinking and roof caving which happen easily at coal roof. It also provides a practical technological guidance for the safety management of anti-caving, especially the safety management at super-large section roadway with thick and fractural coal roof.

4. Application example of prestressed truss cable system in roof safety management of anti-caving 4.1. Project overview

DanShuigou coal mine is located at ShuoZhou of Shanxi Province in China. The thickness of coal seam NO. 9 is 12.53~ 21.49 m and the average thickness is 15.68 m. The angle of coal seam is 14° ~ 20°, and joints are better developed; thickness of the immediate roof is 1.4 ~ 5.5 m consisted of mudstone which is loose and has a lot of cracks, so it makes the roof easy to fall; the thickness of the bottom is 1.4 ~ 5.5 m

(7)

consisted of mudstone, siltstone and sandy mudstone. The width of rectangular section of the open-off cut NO. 9101 is 8.6 m, and its height is 3.8 m.

4.2. Supporting parameters design of the open-off cut NO. 9101

This paper only introduces the simulation process and the result of the prestressed cable truss supporting system with different dip angle and length. The other main parameters are confirmed using similar or engineering analogue methods and we not talk about them in detail.

Table 2. simulation schemes of different length and angle of truss cable

Simulation project Length of truss cable Simulation project Angle of Truss cable

1—2 9.8m 2—1 50°

1—3 10.8m 2—2 60°

1—4 11.8m 2—3 70°

1—5 12.8m 2—4 80°

The surrounding deformation of the prestressed cable truss with different dip angle and length is presented in Table 2.

a) The results of the numerical simulation as shown in Fig. 6. (a) indicate that as length of the truss cable increases from 9.8 m to 11.8 m, the roof deformation decreases from 210 m to 140 m, with the decrease of 33.3%. When the length of truss cable is over 11.8 m, roof deformation changes rarely along with the truss cable length.

70 90 110 130 150 170 190 210 230 9.8 10.8 11.8 12.8 The length of prestressed truss cable (/m)

D ef le ctio n ( /m m )

Convergence of both sides (/mm) The degree of floor heave (/mm) roof subsidence (/mm) 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 50 60 70 80

The angle of prestressed truss cable (/°)

T he r ange of f ai lur e z one ( /m )0

Two sides (/m) Baseplate (/m) Floor (/m)

Fig. 6. (a) Relation between surrounding deformation with the length of truss cable; (b) Relation between the range of failure zone with the angle of truss cable

b) As seen in Fig.6( b), angle of the cable truss has a less influence on the deformation of both sides and floor but a lager influence on the deformation of roof which reaches a minimum value as the angle of the cable truss is 70°, meanwhile, the deformation of both sides and floor remains at a lower level.

4.3. Supporting scheme

a) Roof support: The truss cable adopts high strength and low relaxation prestressed steel strand with

φ15.24 mm,1×7 strands. The length of the truss cable is 11.80 m and the depth of the drill is 12.00 m, which is filled with two φ23×400 mm fast anchoring cartridges and three φ23×800 mm medium-speed anchoring cartridges.

(8)

Top bolt adopts φ20×2500 mm levorotatory and non-longitudinal reinforcement rebar bolt with high-strength, which is anchored by two φ23×800 mm medium-speed anchoring cartridge. There are 11 bolts in each row, and the distance between two top bolts is 800 mm. It is 300 mm from corner bolt whose intersection angle is 15° from vertical line to the sides. Coal roof is used W steel bands, which are rolled from steel plate with a thickness of 4 mm.

15° 20° 250 5° 20° 15° 0 φ15.24mm L=11800mm 5° 2500 380 0 2800 2800 1500 8600 800 800 800 800 800 800 800 800800800 300 300 1500 2800 4300 2800 4300 1500 160 0 600 Depth of drill12000mm Legend Unit:mm Anchor Truss cable

Fig. 7 Complex and active supporting scheme of the open-off cut NO. 9101 and its 3D MAX analogue picture

b) Support of both sides: Side anchor adopts levorotatory and non-longitudinal reinforcement rebar bolt with constant strength which is anchored by oneφ23×400 mm fast anchoring cartridge and one φ23×800 mm medium-speed anchoring cartridge and its length is 2.5 m. The row distance and the distance of two top bolts are both 800 mm; the highest side bolt is placed at 300mm away from the roof which intersection angle is 15° from water level; the other four side bolts are placed horizontally and the distance from the lowest side bolt to the floor is 300 mm. Use diamond-shaped metal nets to protect both sides and the steel staircase beams are circle-wise welded steel.

5. Monitoring and evaluating of support effects

In order to check the control effects of the design supporting scheme, surface displacement of the open-off cut is observed along with the tunneling. As shown in Fig. 8, after adopting the prestressed cable truss supporting system, the roof becomes stable after about 20 days. The largest convergence of both sides is

(9)

less than 124 mm,and the roof subsidence is no more than 163 mm in one month after the excavation and supporting finished. It also shows that the prestressed cable truss can control the surrounding rock effectively and realize the safety management of anti-caving.

6. Conclusions

(1) Stress distribution of individual cells which is obtained from numerical simulation shows that: the concentration of tensile stress is the main reason why roof caving happens easily at the central of roadway, and the extension shape of shear stress is a narrow strip along the length direction of the roadway.

(2) The superiority of the prestressed cable truss can be concluded as: it can provide active and effective supporting force in both horizontal and vertical directions, and make the location of the neutral axis in anchorage zone move down, which puts more coal and rock in the state of multidirectional compressive stress; truss cable goes through the highest shear stress region from the top of the rib and share shear stress with corner bolts and roof beam which can prevent shear failure of the roof and control roof caving of the apex angle effectively.

(3) The application results of the prestressed cable truss combined supporting system in the open-off cut NO. 9101 in Danshuigou coal mine show that: the convergence rate of the roadway is small and the controlling effect of surrounding is well, which solves the problems about safety management of roof caving effectively.

Acknowledgment

Financially supports of National basic research program of the Republic of China (No. 2010CB226802), State Key Laboratory of Coal Resources and Safe Mining (SKLCRSM 10B08), and Fundamental Research Funds for the Central University (No.2010YZ02) are gratefully acknowledged.

References

[1] Peng Cheng, An Analysis of Mine Roof Accidengts Nationwide 2004-2008[J]. Safety in Coal Mine, vol. 36, pp. 104–105, April 2010.

[2] Xie Shengrong, He Fulian, Zhang Shoubao. Technology of the Truss Cable Combined Support on Large Cross-section Compound Mudstone Roof Starting Cut[J]. China Mining Magazine, vol. 17, pp. 90-92. September 2008.

[3] Du Bo, Xie Shengrong, He Fulian. Study on Complex Active Support System of Seam Gateway with Thick Carbonaceous Mudstone Roof[J]. Coal Science ang Technology, vol. 32, pp. 13-16. February 2009.

[4] Zhao Hongliang, Yao Jingming, He Fulian. Application of Prestress Truss Cable in Large Cross Section Coal Roadway[J]. Journal of China Coal Society, vol.32, pp. 1061-1065. February 2007.

[5] He Fulian, Lan Yi, Yin Shuaifeng, Yang Yanhong. Research on Combined Support System of the Super-Large Cross-section Set-up Room at Thick and Broken Coal Seam[J]. Safety in Coal Mine, vol. 38, pp. 73-75, July 2011.

[6] Liu Hongwen. Mechanics of Materials(Ⅰ)[M]. Beijing: Higher Education Press, pp. 140-147. 2004.

[7] Liang Yunpei, Sun Dongling. Study on the Composed Rock Beam Theory of Strata Movement and Its Application[J]. Chinese Journal of Rock Mechanics and Engineering, vol. 21, pp. 654-657. May 2002.

[8] Qian Minggao, Miu Xiexing, Xu Jialin. Theoretical Study of Key Stratum in Ground Control[J]. Journal of China Coal Society, vol. 21, pp. 225-230. March 1996.

Figure

Fig 1. Type and proportion of coal mine accidents in 2010 in China
Table 1. Mechanics parameters of rock and coal samples collected at open-off cut NO.9101 in danshuigou coal mine Material Density (Kg/m³) Shear modulus(MPa) Bulk modulus(MPa) Cohesion(MPa) Internal fiction angle(°) Tensile strength(MPa) Medium-coarse sands
Fig 4. Complex and active control schematic diagram of truss cable system and the force cloud chart of connector
Fig 5. Change of the neutral axis schematic diagram at anchorage zone
+3

References

Related documents

The formal deñnition of VCGen is outside the scope of this paper (it can be found in [2]). Intuitively, the veriñcation condition is a conjunction of boolean expressions

This essay asserts that to effectively degrade and ultimately destroy the Islamic State of Iraq and Syria (ISIS), and to topple the Bashar al-Assad’s regime, the international

innovation in payment systems, in particular the infrastructure used to operate payment systems, in the interests of service-users 3.. to ensure that payment systems

By focusing on multiple categories of owners of a corporation, we contribute in three ways to the literature dealing with minority controlling shareholders (Bebchuk and Weis-

They were immensely proud of the unique fellowship that is shared by the now-adult Pedro Pan, and the help that Operation Pedro Pan Group has given, and continues to give, to

Ýíýõ¿¿ ñóäàëãààíû àæëûí çîðèëãî íü Ìîíãîë îðîíä õà÷èãò ýíöåôàëèòèéí èéëäýñ ñóäëàëûí òàíäàí øèíæèëãýý õèéõ áîëîí ¿¿ñãýã÷èéã in vivo àðãààð ÿëãàí àâ÷ õýâøëèéã

The total coliform count from this study range between 25cfu/100ml in Joju and too numerous to count (TNTC) in Oju-Ore, Sango, Okede and Ijamido HH water samples as