(1)

LEGEND

DOME

IDF

FOCUS

BRIDGE

QTY

10

1

17

0

TURRET

7

ELEMENTARY GROUND FLOOR PLAN

PROJECT TITLE:

GF Roces Building, 704 Pablo Ocampo Sr. St.

Malate Manila, Philippines Tel No.: (02) 254-0888 or (02) 459-9638Fax No.: (02) 254-3550

CLIENT NAME: LOCATION: SHEET CONTENT: SHEET NO.: REVISION NO.: NO. OF DATA: NO. OF VOICE: CAMERA COUNT DOME: TURRET: PTZ: FISHEYE: TOTAL NO. OF CAMERAS:

DRAWN BY:

DATE DRAWN: DOOR ACCESS COUNT

MAGNETIC LOCK: READER: BREAK GLASS: PUSH BUTTON: OVERRIDE:

PROPOSED SURVEILLANCE CCTV

CAM INSTALLATION

ST. STEPHEN HIGH SCHOOL

1267 G. MASANGKAY ST. STA. CRUZ, MANILA

CCTV CAMERA LOCATION PLAN

(2)

Multimedia Activity Area

PROJECT TITLE:

GF Roces Building, 704 Pablo Ocampo Sr. St.

Malate Manila, Philippines Tel No.: (02) 254-0888 or (02) 459-9638Fax No.: (02) 254-3550

CLIENT NAME: LOCATION: SHEET CONTENT: SHEET NO.: REVISION NO.: NO. OF DATA: NO. OF VOICE: CAMERA COUNT DOME: PTZ: FISHEYE: DRAWN BY: DATE DRAWN: DOOR ACCESS COUNT

MAGNETIC LOCK: READER: BREAK GLASS: PUSH BUTTON: OVERRIDE:

LEGEND

DOME

IDF

FOCUS

BRIDGE

QTY

15

1

15

1

TURRET

0

ELEMENTARY SECOND FLOOR PLAN

PROPOSED SURVEILLANCE CCTV

CAM INSTALLATION

ST. STEPHEN HIGH SCHOOL

1267 G. MASANGKAY ST. STA. CRUZ, MANILA

CCTV CAMERA LOCATION PLAN

JCC

TURRET:

TOTAL NO. OF CAMERAS: 15 0 0 0

(3)

PROJECT TITLE:

GF Roces Building, 704 Pablo Ocampo Sr. St.

Malate Manila, Philippines Tel No.: (02) 254-0888 or (02) 459-9638Fax No.: (02) 254-3550

CLIENT NAME: LOCATION: SHEET CONTENT: SHEET NO.: REVISION NO.: NO. OF DATA: NO. OF VOICE: CAMERA COUNT DOME: PTZ: FISHEYE: DRAWN BY: DATE DRAWN: DOOR ACCESS COUNT

MAGNETIC LOCK: READER: BREAK GLASS: PUSH BUTTON: OVERRIDE:

LEGEND

DOME

IDF

FOCUS

BRIDGE

QTY

18

1

18

0

TURRET

0

ELEMENTARY THIRD FLOOR PLAN

PROPOSED SURVEILLANCE CCTV

CAM INSTALLATION

ST. STEPHEN HIGH SCHOOL

1267 G. MASANGKAY ST. STA. CRUZ, MANILA

CCTV CAMERA LOCATION PLAN

JCC

TURRET:

TOTAL NO. OF CAMERAS: 18 0 0 0

(4)

PROJECT TITLE:

GF Roces Building, 704 Pablo Ocampo Sr. St.

Malate Manila, Philippines Tel No.: (02) 254-0888 or (02) 459-9638Fax No.: (02) 254-3550

CLIENT NAME: LOCATION: SHEET CONTENT: SHEET NO.: REVISION NO.: NO. OF DATA: NO. OF VOICE: CAMERA COUNT DOME: PTZ: FISHEYE: DRAWN BY: DATE DRAWN: DOOR ACCESS COUNT

MAGNETIC LOCK: READER: BREAK GLASS: PUSH BUTTON: OVERRIDE:

LEGEND

DOME

IDF

FOCUS

BRIDGE

QTY

18

1

18

0

TURRET

0

ELEMENTARY FOURTH FLOOR PLAN

PROPOSED SURVEILLANCE CCTV

CAM INSTALLATION

ST. STEPHEN HIGH SCHOOL

1267 G. MASANGKAY ST. STA. CRUZ, MANILA

CCTV CAMERA LOCATION PLAN

JCC

TURRET:

TOTAL NO. OF CAMERAS: 18 0 0 0

(5)

PROJECT TITLE:

GF Roces Building, 704 Pablo Ocampo Sr. St.

Malate Manila, Philippines Tel No.: (02) 254-0888 or (02) 459-9638Fax No.: (02) 254-3550

CLIENT NAME: LOCATION: SHEET CONTENT: SHEET NO.: REVISION NO.: NO. OF DATA: NO. OF VOICE: CAMERA COUNT DOME: PTZ: FISHEYE: DRAWN BY: DATE DRAWN: DOOR ACCESS COUNT

MAGNETIC LOCK: READER: BREAK GLASS: PUSH BUTTON: OVERRIDE:

LEGEND

DOME

IDF

FOCUS

BRIDGE

QTY

7

0

7

0

TURRET

0

ELEMENTARY FIFTH FLOOR PLAN

PROPOSED SURVEILLANCE CCTV

CAM INSTALLATION

ST. STEPHEN HIGH SCHOOL

1267 G. MASANGKAY ST. STA. CRUZ, MANILA

CCTV CAMERA LOCATION PLAN

JCC

TURRET:

(6)

Water

Tank Post Maintenance

Garbage

Locker

CR - Female

CR - Male

Hallway Ground

Hallway Second Floor

Hallway Third Floor

GF Roces Building, 704 Pablo Ocampo Sr. St. Tel No.: (02) 254-0888 or (02) 459-9638 Fax No.: (02) 254-3550

PROJECT TITLE:

CLIENT NAME:

LOCATION:

SHEET CONTENT:

PROPOSED SURVEILLANCE CCTV CAM INSTALLATION

NO. OF DATA: CAMERA COUNT DOME: TURRET: PTZ: FISHEYE: TOTAL NO. OF CAMERAS:

DOOR ACCESS COUNT MAGNETIC LOCK: READER: BREAK GLASS: PUSH BUTTON: OVERRIDE: DRAWN BY: DATE DRAWN: SHEET NO.: REVISED NO.:

ST. STEPHEN HIGH SCHOOL

CCTV CAMERA LOCATION PLAN 1267 G. MASANGKAY ST. STA. CRUZ, MANILA

12 NO. OF AP: NO. OF VOICE:

LEGEND

DOME

IDF

FOCUS

9

BRIDGE

QTY

9

1

12

0

TURRET

3

3

Masangkay Gate

ANNEX FLOOR PLAN

(7)

106B CHI CHAMBER

(

241.80

)

G.F. HALLWAY 3

(

241.163

)

LOBBY LEFT

(

241.77

)

G.F. HALLWAY 2 (241.74)

LOBBY MAIN ENTRANCE

(

241.75)

LOBBY WAITING LEFT

(

241.76

)

QUADRANGLE LEFT

(

241.161)

LOBBY WAITING RIGHT

(

241.72

)

106A P.M.C

(

241.79

)

LOBBY RIGHT

(

241.73)

G.F. HALLWAY 1

(

241.164

)

107 CONF ROOM

(

241.81

)

GATE TO P.S

(

241.165)

105 SHALOM (241.78)

GATE TO CANTEEN

(

241.166

)

GATE TO LA TORRE

(

241.167

)

QUADRANGLE RIGHT

(

241.162

)

PORT ILLUSTRATION - GROUND FLOOR (IDF)

(8)

R.M 214

(

241.100

)

SPARE

R.M 208

(

241.96

)

LIBRARY BACK

(

241.106

)

LIBRARY ACTIVITY RM

(

241.107)

R.M 210

(

241.98

)

LIBRARY LEFT

(

241.105)

GROUND SW PORT 7

R.M 212

(

241.99

)

BOOK RM/ P.E RM

(

241.97)

LIBRARY RIGHT

(

241.104

)

2F HALLWAY 3

(

241.123

)

FACULTY ROOM LEFT

(

241.102)

FACULTY ROOM RIGHT

(

241.101

)

LIBRARY FRONT

(

241.103

)

SPARE

SPARE

PORT ILLUSTRATION - 2ND FLOOR (IDF)

S/N 10008854413

DS-3E0326P-E/M

POE INJECTOR

POE SWITCH

POE INJECTOR

2ND FLOOR SW G1

AIRMAX RADIO BRIDGE

(9)

R.M 302

(

241.145

)

R.M 304

(

241.147

)

R.M 306

(

241.149

)

R.M 308

(

241.151

)

3F COMPLAB(F)

(

241.155)

R.M 310

(

241.153

)

3F COMPLAB(B)

(

241.157)

3F HALLWAY 1

(

241.125

)

3F HALLWAY 2

(

241.94

)

2F HALLWAY 1 (241.122)

3F GUIDANCE

(

241.144

)

R.M 303

(

241.146)

R.M 305

(

241.148

)

R.M 307

(

241.150

)

R.M 309

(

241.152)

R.M 311

(

241.154

)

R.M 313

(

241.156

)

3F HALLWAY 4

(

241.124

)

3F HALLWAY 3

(

241.95

)

PORT ILLUSTRATION - 3RD FLOOR (IDF)

(10)

4F COMLAB

(

241.130

)

R.M 403

(

.241.132

)

R.M 405

(

241.134

)

R.M 407 (241.136)

R.M 410

(

241.139)

R.M 409

(

241.138

)

4F HE(F)

(

241.141)

5F HALLWAY 1

(

241.128

)

S.HALL FRONT LEFT

(

241.110

)

5F HALLWAY 2 (241.129)

S.HALL FRONT RIGHT

(

241.111

)

4F HALLWAY 4

(

241.126

)

4F SCIENCE(F)

(

241.131

)

4F SCIENCE(B)

(

241.133)

R.M 406

(

241.135

)

R.M 408

(

241.137

)

R.M 413

(

241.142)

4F HE(B) (241.143)

4F HALLWAY 1

(

241.127

)

R.M 411

(

241.140

)

AVR ROOM

(

241.112

)

S.HALL REAR RIGHT

(

241.109

)

S.HALL REAR LEFT

(

241.108

)

8 PORT SWITCH

PORT ILLUSTRATION - 4TH FLOOR (IDF)

(11)

3F ANNEX RM 54

(

241.86

)

LOCKER 1

(

241.91

)

MAGSANGKAY GATE 1

(

241.158

)

MAGSANGKAY GATE 2

(

241.159

)

SPARE

2F ANNEX

(

241.89

)

MAINTENANCE POST

(

241.160

)

3F ANNEX RM 53

(

241.87

)

3F ANNEX

(

241.88)

WALKWAY TO ANNEX

(

241.90

)

LOCKER 2

(

241.92

)

3F ANNEX RM 55

(

241.85)

3F ANNEX RM 56

(

241.84

)

PORT ILLUSTRATION - ANNEX (IDF)

(12)

NVR1

GROUND SW PORT 9

DS-7732NI-K4

192.168.1.241.250

NVR2

GROUND SW PORT 12

NVR3

GROUND SW PORT 11

PORT ILLUSTRATION - CCTV ROOM

References

Related documents

PROJECT: SEAL AND SIGNATURE: LICENSE NO: SHEET TITLE: SHEET NO: CHECKED: SCALE: DRAWN: DATE: REMARK: DATE: ISSUES: NO: NJ 13869 MORGAN RESIDENCE 14 Montgomery Ave.. PROJECT: SEAL

The retailer uses different TLOU prices for low and high emission costs, thus encouraging the customers to shift demand accordingly, and the total cost of the customers

The rotation rate of the Earth is practically constant, therefore if an accurate clock drive were attached to the right ascension axis of an equatorial mount, the telescope

Door 1 Controller Side View Exit Switch Card Reader Door 1 Magnetic Lock Door Contact Door 2 Door 2 Controller To OPTIONAL Host PC with additional Access Software.. SELECTION

This plan should be clearly presented, drawn to scale and include the date it was prepared (any revised plans must include the date). The plan must include the location of all

To lock the driver’s door, remove the key from the ignition switch, pull the outside door handle and push the lock tab down or push the master switch down.. Release the handle,

Step 5 • Within 25 second, push x on next remote lock or unlock button shortly • Push lock or unlock button from every.. other alarm

The researchers conclude that there is no significant difference between males and females, in terms of time duration among the four conditions, namely: a) verbal b) intrinsic