LED WALL WASHERS
SPECIFICATIONS
ContentS:
Brief SpeCifiCationS
120V LED WALL WASHER • WWF 12 48 ... 4
120V LED WALL WASHER • WWB 14 36 ... 5
120V LED WALL WASHER • WWS 16 12... 6
120V LED WALL WASHER • WWS 32 24 ... 7
120V LED WALL WASHER • WWS 48 36 ... 8
24V LED WALL WASHER • WWT 15 12 ... 9
24V LED WALL WASHER • WWT 24 90 ...10
24V LED WALL WASHER • WWT 48 180 ...11
inStallation GUiDe
WWS, WWF, WWB SERIES • HARD WIRE ...12
WWS, WWF, WWB SERIES • PLUG & PLAY ...13
WWT SERIES • HARD WIRE ...14
IMPORTANT SAFETY INSTRUCTIONS
When installing or using this product, basic safety
precautions should always be followed including
the following:
1. Read all instructions before attempting to
install this product.
2. Ensure main power is off before installing or
wiring this product.
3. Ensure correct voltage is being used for this
product.
4. Disconnect electrical power before adding to
or changing the configuration of this product.
5. Fixtures must be installed by a qualified
SpeCifiCationS Model WWf 12 48 pp 60 W30 WWf 12 48 pp 60 W50 WWf 12 48 pp 60 rGB WWf 12 48 pp 60 aWB leD Quantity 48 Wattage 56 W lumens 2500 lm 3300 lm 1890 2360 efficacy 44.6 lm/W 58.9 lm/W 33.8 lm/W 42.1 lm/W
Color 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
Beam angle 120° x 60°
Cri 75 N/A
Voltage 100-240V AC
lamp life 50,000 hours
Dimensions 12 1/2"L × 10 5/8"H × 7 3/4"D
Weight 11.5 lbs / 5.2 kg
Housing Aluminum
finish† Z – Bronze (Standard)
operating temperature -4°F – 113°F / -20°C – 45°C
operating Humidity 10% - 90% RH
Mounting Bracket and handle. Steel Yoke with bolt holes and screw holes.
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. † Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWf 12 48 pp - Plug & Play 60 - 60°x120° W30 - 3000K Z - Bronze
HW - Hard Wire* W60 - 6000K a - Aluminum*
rGB B - Black*
aWB W - White*
* Custom options – Consult factory
example: WWf 12 48 – pp – 60 – W30 – Z
7-3/4" 12-1/2"
10-5/8"
SPECIFICATIONS Model WWB 14 36 PP 30 W30 WWB 14 36 PP 30 W50 WWB 14 36 PP 30 RGB WWF 14 36 PP 30 AWB LED Quantity 36 Wattage 40W Lumens 1500 lm 2000 lm 1143 1429 Efficacy 37.5 lm/W 50 lm/W 28.6 lm/W 35.8 lm/W
Color 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
CRI 75 N/A
Beam Angle* 30°
Voltage 100-240V AC
Lamp Life 50,000 hours
Dimensions 13 1/2" L x 11 1/2" H x 6 3/8" D
Weight 10 lbs / 4.5kg
Housing Aluminum
Finish† Z – Bronze (Standard)
Operating Temp -4°F – 113°F / -20°C – 45°C
Operating Humidity 10% - 90% RH
DMX Input 3 Pin Washer DMX Plug
Mounting Screw holes on steel baseplate with integral 24V DC 350mA power supply
Maximum Run‡ 16 Fixtures or 1,000 feet
Environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information.
* Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
ORDERING INSTRUCTIONS
MODEL WIRING TYPE BEAM ANGLE CCT FINISH
WWB 14 36 PP - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K A - Aluminum*
60 - 60° * RGB B - Black*
AWB W - White*
* Custom options – Consult factory
SpeCifiCationS Model WWS 16 12 pp 30 W30 WWS 16 12 pp 30 W50 WWS 16 12 pp 30 rGB WWS 16 12 pp 30 aWB leD Quantity 12 Wattage 14W lumens 816 1044 597 746 efficacy 58.3 lm/W 74.6 lm/W 42.6 lm/W 53.3 lm/W
Color 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
Beam angle* 30°
Cri 75 N/A
Voltage 100-240V AC
lamp life 50,000 hours
Dimensions 16 3/8" L x 2 3/4" W x 4 1/2" H
Weight 4 lbs / 1.8 kg
Housing Aluminum
finish† Z – Bronze (Standard)
operating temp -22°F – 104°F / -30°C – 40°C
operating Humidity 10% - 90% RH
DMX input 3 Pin Washer DMX male Plug
Mounting Steel Yoke with bolt holes and screw holes
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. * Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWS 16 12 pp - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K a - Aluminum*
60 - 60° * rGB B - Black*
aWB W - White*
* Custom options – Consult factory
SpeCifiCationS Model WWS 32 24 pp 30 W30 WWS 32 24 pp 30 W50 WWS 32 24 pp 30 rGB WWS 32 24 pp 30 aWB leD Quantity 24 Wattage 28W lumens 1100 1500 857 1071 efficiency 39.3 lm/w 53.6 lm/w 30.6 lm/w 38.25 lm/w
Color temperature 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
Cri 75 N/A
Beam angle* 30°
Voltage 100-240V AC
lamp life 50,000 hours
Dimensions 32" L x 2 3/4" W x 4 1/2" H
Weight 5.5 lbs / 2.5 kg
Housing Aluminum
finish† Z – Bronze (Standard)
operating temperature -22°F – 104°F / -30°C – 40°C
operating Humidity 10% - 90% RH
DMX input 3 Pin Washer DMX male Plug
Mounting Steel Yoke with bolt holes and screw holes
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. * Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWS 32 24 pp - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K a - Aluminum*
60 - 60° * rGB B - Black*
aWB W - White*
* Custom options – Consult factory
SpeCifiCationS Model WWS 48 36 pp 30 W30 WWS 48 36 pp 30 W50 WWS 48 36 pp 30 rGB WWS 48 36 pp 30 aWB leD Quantity 36 Wattage 45W lumens 1500 2000 1143 1429 efficacy 33.3 lm/W 44.4 lm/W 25.4 lm/W 31.8 lm/W
Color temperature 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
Beam angle* 30°
Cri 75 N/A
Voltage 100-240V AC
lamp life 50,000 hours
Dimensions 47 7/8" L x 2 3/4" W x 4 1/2" H
Weight 8.8 lbs / 4 kg
Housing Aluminum
finish† Z – Bronze (Standard)
operating temp -22°F – 104°F / -30°C – 40°C
operating Humidity 10% - 90% RH
DMX input 3 Pin Washer DMX male Plug
Mounting Steel Yoke with bolt holes and screw holes
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. * Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWS 48 36 pp - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K a - Aluminum*
60 - 60° * rGB B - Black*
aWB W - White*
* Custom options – Consult factory
SpeCifiCationS
Model WWt 15 12 pp 30 W30 WWt 15 12 pp 30 W50 WWt 15 12 pp 30 rGB WWt 15 12 pp 30 aWB
leD Quantity 12 (Bridgelux)
Wattage 15W
lumens 816 1044 600 750
efficacy 54.4 69.6 40 lm/W 50 lm/W
Color 3000K – 3500K 5000K – 5500K Red, Green, Blue Amber, White, Blue
Beam angle* 30°
Voltage† 24V DC
efficiency 0.9 PF
lamp life 50,000 hours
Dimensions 15 1/2" L x 6 3/4" W x 5 1/4" H
Weight 6.6 lb
Housing Aluminum
finish Z – Bronze (Standard)
operating temp -4°F – 113°F / -20°C – 45°C
operating Humidity 10% - 90% RH
DMX input 3 pin Jesco DMX plug
Mounting Surface Mount
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. * Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWt 15 12 pp - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K a - Aluminum*
60 - 60° * rGB B - Black*
aWB W - White*
* Custom options – Consult factory
example: WWt 15 12 – pp – 30 – W30 – Z 15-1/2"L 1-7/8" 13-3/8" 6 -3 /4 "W 5-1/4"H 2-1/ 8" 5 -3 /4 " 3-1/ 4"
SpeCifiCationS
Model WWt 24 90 pp 30 W30 WWt 24 90 pp 30 W50 WWt 24 90 pp 30 rGB WWt 24 90 pp 30 aWB
leD Quantity 36 (Bridgelux)
Wattage 105W
lumens 5100 lm 6000 lm 3429 4286
efficacy 48.6 lm/W 57.1 lm/W 32.7 lm/W 40.8 lm/W
Color 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
Beam angle* 30°
Voltage† 24V DC
efficiency PF 0.60
lamp life 50,000 hours
Dimensions 23 5/8" L x 7 3/8" W x 5 1/2" H
Weight 11 lbs / 5 kg
Housing Aluminum
finish Z – Bronze (Standard)
operating temp -4°F – 113°F / -20°C – 45°C
operating Humidity 10% - 90% RH
DMX input 3 pin Jesco DMX plug
Mounting Surface Mount
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. * Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; A – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWt 24 90 pp - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K a - Aluminum*
60 - 60° * rGB B - Black*
aWB W - White*
* Custom options – Consult factory
example: WWt 24 90 – pp – 30 – W30 – Z 5 -1/ 2" H 7-3/8"W 23-5/8"L
SpeCifiCationS
Model WWt 48 180 pp 30 W30 WWt 48 180 pp 30 W50 WWt 48 180 pp 30 rGB WWt 48 180 pp 30 aWB
leD Quantity 72 (Bridgelux)
Wattage 176W
lumens 7100 lm 8200 lm 4686 5857
efficacy 40.3 lm/W 46.6 lm/W 26.6 lm/W 33.3 lm/W
Color 3000K – 3500K 5500K – 5500K Red, Green, Blue Amber, White, Blue
Beam angle* 30°
Voltage† 24V DC
efficiency PF 0.60
lamp life 50,000 hours
Dimensions 47 3/8" L x 7 3/8" W x 5 1/2" H
Weight 20.3 lbs / 9.2 kg
Housing Aluminum
finish Z – Bronze (Standard)
operating temp -4°F – 113°F / -20°C – 45°C
operating Humidity 10% - 90% RH
DMX input Jesco DMX 3-pin plug 3 pin Washer DMX plug
Mounting Surface Mount
Maximum run‡ 16 Fixtures or 1,000 feet
environment Dry, Wet, IP65
Certifications ETL/cETL, CE, RoHS
Warranty 5 Years – see published warranty terms for detailed information. * Consult the factory for custom beam angles: 15° and 60°.
† Consult factory for custom finishes; a – Aluminum (MOQ 50 pcs), B – Black (MOQ 150 pcs), W – White (MOQ 150 pcs). ‡ View installation instructions for detailed information.
orDerinG inStrUCtionS
MoDel WirinG tYpe BeaM anGle CCt finiSH
WWt 48 180 pp - Plug & Play 30 - 30° W30 - 3000K Z - Bronze
HW - Hard Wire* 15 - 15° * W60 - 6000K a - Aluminum*
60 - 60° * rGB B - Black*
aWB W - White*
* Custom options – Consult factory
example: WWt 48 180 – pp – 30 – W30 – Z 5 -1/ 2" H 7-3/8"W 47-3/8"L
WWS, WWf, WWB SerieS • HARD WIRE
1. Configure design and lay out the systembefore attempting to install this product. note – A DMX controller is required to operate Wall Washer fixtures. Additional DMX adapter cables may be required.
2. Set DMX address
Locate the DMX addressing interface on the fixture. Power the fixture. Select a DMX address (000 – 512). Each address consists of 3 channels (R-G-B or A-W-B).
To control fixtures individually, assign a unique DMX address per fixture.
To control fixtures at the same time, assign the same DMX for each fixture.
3. enSUre Main poWer iS off. 4. install fixtures
Determine locations on the mounting surface according to the desired design and layout. Ensure fixtures are installed within the maximum run length of DMX cable (1,000 feet or 300 feet for CAT5 cable). DMX wiring must be installed in a continuous run (daisy chained). Connect main power wires to Washer fixture. optional
A DMX Distribution Amplifier is required for multiple runs (star wiring) or when installing more than 16 fixtures.
5. Connect fixtures
Connect fixtures using DMX cable. Ensure a tight connection is made by tightening the lock nut. For harsh environments you may use a silicon compound to seal the connectors. For hardwiring, use weatherproof boxes and covers as needed (supplied by others).
6. Connect Controller
Run DMX cable from the controller to the first fixture. If no controller is connected and the DMX address is set to 001, the fixture will enter into the default test mode and cycle colors.
See Controller specification sheet for more details.
7. run System
Turn the power on. Check all fixtures to make sure they are running properly. If fixtures are not running properly, check all connections and retighten.
DL-PS-XX/24-HW 120V 120V Max. 16 fixtures 2-port DMX Distribution 120V Box by others Box by others Box by others Box by others Box by others Main Power 120V DMX CONTROLLER* 120V LC-DMX-AMP2 WWB, WWF, or WWS WWB, WWF, or WWS WWB, WWF, or WWS WWB, WWF, or WWS
120V AC DL-PS-XX/24-JB 120V AC DL-PS-XX/24-JB 120V AC 120V AC LC-DMX-AMP2 2-port DMX Distribution DMX Adressing Interface To DMX CONTROLLER* WWB, WWF or WWS WWB, WWF or WWS 120V AC 120V AC WWB, WWF or WWS LC-DMX-AMP1 1-port DMX Distribution WWB, WWF or WWS Max. 16 fixtures
* See controller specification sheet for more details.
WWS, WWF, WWB SERIES • PLUG & PLAY
1. Configure design and lay out the systembefore attempting to install this product. note – A DMX controller is required to operate Wall Washer fixtures. Additional DMX adapter cables may be required.
2. Set DMX address
Locate the DMX addressing interface on the fixture. Power the fixture. Select a DMX address (000 – 512). Each address consists of 3 channels (R-G-B or A-W-B).
To control fixtures individually, assign a unique DMX address per fixture.
To control fixtures at the same time, assign the same DMX for each fixture.
3. enSUre Main poWer iS off. 4. install fixtures
Determine locations on the mounting surface according to the desired design and layout. Ensure fixtures are installed within the maximum run length of DMX cable (1,000 feet or 300 feet for CAT5 cable). DMX wiring must be installed in a continuous run (daisy chain.
optional
A DMX Distribution Amplifier is required for multiple runs (star wiring) or when installing more than 16 fixtures.
5. Connect fixtures
Connect fixtures using DMX cable. Ensure a tight connection is made by tightening the lock nut.
For harsh environments you may use a silicon compound to seal the connectors. For hardwiring, use weatherproof boxes and covers as needed (supplied by others). 6. Connect Controller
Run DMX cable from the controller to the first fixture.
If no controller is connected and the DMX address is set to 001, the fixture will enter into the default test mode and cycle colors.
See Controller specification sheet for more details.
7. run System
WWt SerieS • HARD WIRE
1. Configure design and lay out the systembefore attempting to install this product. note – A DMX controller is required to operate Wall Washer fixtures. Additional DMX adapter cables may be required.
2. install power Supply
Determine location of the power supply. Connect low voltage wires from power supply to the fixture. Ensure correct polarity is connected (positive to positive, negative to negative).
3. Set DMX address
Locate the DMX addressing interface on the fixture. Power the fixture. Select a DMX address (000 – 512). Each address consists of 3 channels (R-G-B or A-W-B).
To control fixtures individually, assign a unique DMX address per fixture.
To control fixtures at the same time, assign the same DMX for each fixture.
4. enSUre Main poWer iS off. 5. install fixtures
Determine locations on the mounting surface according to the desired design and layout. Ensure fixtures are installed within the maximum run length of DMX cable (1,000 feet or 300 feet for CAT5
cable). DMX wiring must be installed in a continuous run (daisy chained). Connect main power wires to Washer fixture. optional: A DMX Distribution Amplifier is required for multiple runs (star wiring) or when installing more than 16 fixtures.
Connect fixtures
Connect fixtures using DMX cable. Ensure a tight connection is made by tightening the lock nut.
For harsh environments you may use a silicon compound to seal the connectors. For hardwiring, use weatherproof boxes and covers as needed (supplied by others). See Controller specification sheet for more details.
6. Connect Controller
Run DMX cable from the controller to the first fixture.
If no controller is connected and the DMX address is set to 001, the fixture will enter into the default test mode and cycle colors. 7. run System
Turn the power on. Check all fixtures to make sure they are running properly. If fixtures are not running properly, check all connections and retighten.
DL-PS-XX/24-HW 120V 120V Max. 16 fixtures 2-port DMX Distribution 120V Box by others Main Power 120V DMX CONTROLLER* 120V LC-DMX-AMP2 WWT WWT WWT WWT 24V 24V 24V 24V 24V DL-PS-XX/24-HW DL-PS-XX/24-HW Box by others Box by others Box by others DL-PS-XX/24-HW Box by others DL-PS-XX/24-HW
WWT SERIES • PLUG & PLAY
1. Configure design and lay out the systembefore attempting to install this product. note – A DMX controller is required to operate Wall Washer fixtures. Additional DMX adapter cables may be required.
2. install power Supply
Determine location of the power supply. Connect low voltage wires from power supply to the power connector (WW-PC-HW/DC-72). Ensure correct polarity is connected (positive to positive, negative to negative). Connect power connector to the Washer fixture.
3. Set DMX address
Locate the DMX addressing interface on the fixture. Power the fixture. Select a DMX address (000 – 512). Each address consists of 3 channels (R-G-B or A-W-B).
To control fixtures individually, assign a unique DMX address per fixture.
To control fixtures at the same time, assign the same DMX for each fixture.
4. enSUre Main poWer iS off. 5. install fixtures
Determine locations on the mounting surface according to the desired design and layout. Ensure fixtures are installed
within the maximum run length of DMX cable (1,000 feet or 300 feet for CAT5 cable). DMX wiring must be installed in a continuous run (daisy chained). Connect main power wires to Washer fixture. optional: A DMX Distribution Amplifier is required for multiple runs (star wiring) or when installing more than 16 fixtures.
Connect fixtures
Connect fixtures using DMX cable. Ensure a tight connection is made by tightening the lock nut.
For harsh environments you may use a silicon compound to seal the connectors. For hardwiring, use weatherproof boxes and covers as needed (supplied by others). See Controller specification sheet for more details.
6. Connect Controller
Run DMX cable from the controller to the first fixture. If no controller is connected and the DMX address is set to 001, the fixture will enter into the default test mode and cycle colors. 7. run System
Turn the power on. Check all fixtures to make sure they are running properly. If fixtures are not running properly, check all connections and retighten.
DL-PS-XX/24-HW 120V 120V Max. 16 2-port DMX Distribution 120V Box by others Main Power 120V DMX CONTROLLER* 120V LC-DMX-AMP2 WWT WWT WWT WWT 24V 24V 24V 24V 24V DL-PS-XX/24-HW DL-PS-XX/24-HW Box by
others Box by others
Box by others DL-PS-XX/24-HW Box by others DL-PS-XX/24-HW WW-PC-HW/DC-72 WW-PC-HW/DC-72 WW-PC-HW/DC-72 WW-PC-HW/DC-72