• No results found

USED SYRINGES ANALYSIS : A NEW APPROACH TO BETTER KNOW THE INJECTED DRUG USES AND USERS

N/A
N/A
Protected

Academic year: 2021

Share "USED SYRINGES ANALYSIS : A NEW APPROACH TO BETTER KNOW THE INJECTED DRUG USES AND USERS"

Copied!
25
0
0

Loading.... (view fulltext now)

Full text

(1)

USED SYRINGES ANALYSIS :

A NEW APPROACH TO

BETTER KNOW THE INJECTED

DRUG USES AND USERS

Thomas NEFAU

a

, Catherine DUPLESSY-GARSON

a

, Jean-Louis BARA

a

,

Sara KAROLAK

b

, Vincent THIBAULT

c

,Yves LEVI

b

a

SAFE Association

(2)

Introduction

• 280 000 problem drug users

– 70 000 of them are low threshold structures’ clients

1

Those who answer to surveys

o

Declarative bias

What about the hidden users?

Little is known about the substances injected

(3)

CHEMICAL ANALYSIS

(4)

illicit

drugs

&

NPS

(5)

Substances

misused

medical

(6)

Site locations

Cergy

Colombes

Saint-Denis

Aulnay-

s/s-Bois

Bichat

hospital

Gare

St-Lazare

Gare

du Nord

Colonel

Fabien

Bastille

Gare

de Lyon

Chevaleret

Kennedy

Javel

Les Halles

Gare

Montparnasse

Chaumont

Melun

Montargis

Mantes-La-Jolie

Reims

Aubervilliers

(7)

Samples preparation for chemical analysis

Recovering drug residues from

used syringe

methanol

methanol +

residues

used

syringe

(8)

sample filtration

recovering drug residues from used

syringe

Samples preparation for chemical analysis

Recovering drug residues from

used syringe

methanol

used

syringe

methanol +

residues

clean

syringe

(9)

HPLC

Tandem mass spectrometry

Analytical method

TO SUM UP

4 sampling campaigns (2010, 2012, 2013, 2014)

32 sites

5562 samples

(10)

Results - example

Date

25/03/2014

Syringes analyzed

30

Kennedy station

Substances Syringes Composition

0 3 1 1 4-MEC 4 x-MMC 2 1 4-MEC / COC 7 4-MEC / x-MMC 1 4-MEC / MePHEN 1 4-MEC / MOR 1 x-MMC / COC 1 x-MMC / MePHEN 1 x-MMC / METHOX 1 x-MMC / METHYLONE 3 1 x-MMC / MePHEN / METHYLONE 1 4-MEC / x-MMC / COC 2 4-MEC / x-MMC / METHOX 4

1 4-MEC / x-MMC / COC / METHOX 1 4-MEC / x-MMC / COC / MOR 1 4-MEC / x-MMC / MePHEN /

METHOX

5 1 4-MEC / x-MMC / METHOX /

METHYLONE / MOR

Syringes with blood

6

Syringes with broken needle

0

Syringes with graduations erased

3

(11)

Results - 2014

Aubervilliers

Aulnay

s/s-Bois

Gare

de Lyon

Javel

Mantes-La-Jolie

Gare

Montparnasse

Reims

Melun

Montargis

Gare

St-Lazare

Chaumont

Gare

du Nord

25

50

100

Kennedy

%

(12)
(13)

Results - example

Date

25/03/2014

Syringes analyzed

30

Kennedy station

Substances Syringes Composition

0

3

1

5

4-MEC x-MMC 2

14

4-MEC / COC 4-MEC / x-MMC 4-MEC / MePHEN 4-MEC / MOR x-MMC / COC x-MMC / MePHEN x-MMC / METHOX x-MMC / METHYLONE 3

4

x-MMC / MePHEN / METHYLONE 4-MEC / x-MMC / COC 4-MEC / x-MMC / METHOX 4

3

4-MEC / x-MMC / COC / METHOX 4-MEC / x-MMC / COC / MOR 4-MEC / x-MMC / MePHEN / METHOX

5

1

4-MEC / x-MMC / METHOX /

METHYLONE / MOR

Syringes with blood

6

Syringes with broken needle

0

Syringes with graduations erased

3

(14)
(15)

Aulnay

s/s-Bois

Javel

Kennedy

(16)

Aulnay

s/s-Bois

Javel

Kennedy

2014 2012 2010

Results - trends

(17)

Aulnay

s/s-Bois

Javel

Kennedy

2014 2012 2010 2014 2012 2010

Results - trends

(18)

Aulnay

s/s-Bois

Javel

Kennedy

2014 2012 2010 2014 2012 2010 2014 2012 2010

Results - trends

(19)

VIROLOGICAL ANALYSIS

Virology Laboratory, Hôpital Pitié-Salpêtrière,

(20)

Samples preparation for virological analysis

used

syringe

Sterilized

water

Liquid was stored frozen at -20°C until

further use.

HBsAg was detected on the residual

volume of collected rinsing water using the

Abbott Architect system (HBsAg reagent).

The lower limit of detection for HBsAg was

0.05 IU/mL.

Viral RNA was extracted using the Abbott

M2000sp (sample preparation) system.

The purified RNA was analyzed using

consecutively by:

Real time HIV reagents for HIV,

Real time HCV reagents for HCV

RNA

The limit of detection for HIV was 50

copies/mL and for HCV 12 IU/mL.

(21)

Results - virology

In %

HCV (RNA)

HIV (Ag-Ab)

HBV (AgHBs)

Budapest street

(n=75)

4

4

3

Gare de Lyon

(n=70)

12

7

0

Mantes-La-Jolie

(n=71)

4

1.5

0

Javel station

(n=60)

30

0

0

HBV seems to be a

minor concern

(22)

Results - virology

In %

HCV (RNA)

HIV (Ag-Ab)

HBV (AgHBs)

Budapest street

(n=75)

4

4

3

Gare de Lyon

(n=70)

12

7

0

Mantes-La-Jolie

(n=71)

4

1.5

0

Javel station

(n=60)

30

0

0

HIV was observed in a very

small proportion of

(23)

Results - virology

In %

HCV (RNA)

HIV (Ag-Ab)

HBV (AgHBs)

Budapest street

(n=75)

4

4

3

Gare de Lyon

(n=70)

12

7

0

Mantes-La-Jolie

(n=71)

4

1.5

0

Javel station

(n=60)

30

0

0

HCV seems to be more problematic:

- contaminated syringes were found in all sites

- not a surprise given the estimated prevalence

The site with the highest number of contaminated

syringes is located far away from any harm reduction

(24)

Conclusion

• Limits:

– Different ways to get rid of syringes (collect in structure, pharmacy…)

– A person can throw away 20 syringes while 10 people can throw away

2 each

– The syringes may have been disposed of several weeks after use

• Degradation of molecules and viruses

• New tools to assess the drug consumptions and to estimate a HIV/HCV

prevalence of a particular population of drug users

• Objective observations

– Analytical chemistry

– Virology tests

(25)

Thank you for your attention

Drug analysis of residual content of used syringes: A new approach for improving knowledge of

injected drugs and drug user practices. Int J Drug Policy. Volume 26, Issue 4, April 2015, Pages 412–

419. doi:10.1016/j.drugpo.2014.09.010.

Hepatitis C transmission in injection drug users: could swabs be the main culprit? J Infect Dis. 2011

Dec 15;204(12):1839-42.

References

Related documents

Seven teen selected samples mineral analysis results of seafloor surfacial sediment are found a rare earth element bearing minerals such as apatite, monazite, xenotime, zircon

That’s exactly the kind of scenario the California Emergency Medical Services Authority (EMSA) was preparing for last week when more than 200 people converged on Sacramento

Inner pocket for Zip-City (accessory for size S),

enhances opportunity for approval and helps with ancillary financing needs that the company has with the bank (LOC, equipment financing, etc.).  ESCDC works seamlessly with

Table 24: European Recent Past, Current & Future Analysis for Internet of Things by Geographic Region - France, Germany, Italy, UK, Spain, and Rest of Europe Markets

In addition, small uniaxial tensile specimens were fabricated from the mother tube wall in axial and hoop directions, and tension–compression reverse loading tests were performed

SEM micrographs showing (a) the overall view of the fatigue fracture surface of AA6061-T6, (b) a drawing line distribution of fatigue voids at low magnification and (c)

Exposure Response Relationship: In clinical studies of neutropenic patients who were receiving cytotoxic chemotherapy for acute myelogenous leukemia (AML) or myelodysplastic