• No results found

Products Arrivals 2012

N/A
N/A
Protected

Academic year: 2021

Share "Products Arrivals 2012"

Copied!
44
0
0

Loading.... (view fulltext now)

Full text

(1)

Products

Products

Arrivals

 

2012

(2)

Super Daiseikai 6.5 [RAS‐B10/13/16N3KVP‐E] Super Daiseikai 6 [RAS‐10/13/16SKVP2‐E] Suzumi Plus [RAS‐B10/13/16/18/22N3KV2‐E] [RAS‐BxxUFV‐E] Suzumi Plus [RAS‐10/13/16/18/22SKV2‐E] AvAnt

[RAS‐107SKV‐E4] .. To match EuP Lot10 [RAS‐137/167SKV‐E3]

Fix Speed

[RAS‐10/13/18/24SKHP‐ES2]

‐‐Phase out ‐‐

RAS

 

Single

 ‐

Line

 

Up

C

 

O

 

P

High

 

Tier

       

Mid

 

Tier

      

Entry

 

Tier

(3)

Super Daiseikai 6.5 [RAS‐B10/13/16N3KVP‐E] Suzumi plus [RAS‐B10/13/16/22N3KV2‐E] Suzumi [RAS‐M10/13/16SKV‐E] Duct [RAS‐MxxGDV‐E] Compact Cassette [RAS‐MxxSMUV‐E] Console [RAS‐BxxUFV‐E]

RAS

 

Multi

 ‐

Line

 

Up

 

Indoor

(4)

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

ƒ

TOSHIBA

 

High

tier

 

model

ƒ

New

 

modern

 

design

ƒ

Size

 

10,

 

13,

 

16

ƒ

Standard

 

model

 

white,

 

option

 

grey

 

panel

ƒ

B

Code

 

(same

 

model

 

for

 

single

 

and

 

multi

 

use)

– Single use, with Daiseikai‐CDU, energy efficiency „Daikeikai‐level“ – Multi use with all current Multi CDU (M18, 3M26, 4M27, 5M34)

ƒ

Well

 

known

 

Daiseikai

 

filter

 

system

  

(plasma

 

air

 

purifier,…)

RAS‐B10N3KVP‐E RAS‐10N3AVP‐E RAS‐B13N3KVP‐E RAS‐13N3AVP‐E RAS‐B16N3KVP‐E RAS‐16N3AVP‐E EER 5.12 4.19 3.38 COP 5.10 4.44 3.76

(5)

Concept:High‐tier Hi‐wall DaiSeiKai Inverter

Capacity: 10, 13 and 16k Btu  Indoor unit: GEN3 (2012 Design)

Outdoor unit: 630H  800mm 300mm 630mm 790mm 225mm 275mm NEW RAS‐B10N3KVP‐E RAS‐B13N3KVP‐E RAS‐B16N3KVP‐E RAS‐10N3AVP‐E RAS‐13N3AVP‐E RAS‐16N3AVP‐E “Bi‐function indoor unit”be able to operate either single or multi connection

Super

 

Daiseikai

 

6.5

(6)

Indoor units combinations examples 2:1 RAS‐M14GAV‐E RAS‐M18UAV‐E 3:1 RAS‐3M18SAV‐E 5:1 RAS‐5M34UAV‐E1 4:1 RAS‐4M23SAV‐E

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

(7)

Low noise and low vibration

Energysaving(low revolution–lessthan30rps)

High reliability (low load to shaft) Uses R410A refrigerant

Energy saving (high motor efficiency) High energy‐saving control

High power‐factor control

DC Hybrid Inverter

DC‐Motor

Twin‐rotary Cylinder

Advanced

 

technology

~

 

Toshiba

 

DC

 

Hybrid

 

Inverter

~

PAM  provides  the highest levels of  power, while PWM ensures ideal room 

temperature and optimum energy efficiency. As a hybrid, the Toshiba Inverter  

System features  the best of both. 

•PAM  (Pulse Amplitude Modulation) ** PWM  (Pulse Width Modulation)

High power

+

High efficiency

=

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

(8)

Advanced

 

comfort

 

&

 

cleaning

Plasma Air Purifier + Air Ionizer + Toshiba IAQ Filter 

10X Active Purification with Super Fresh

Plasma Air Purifier Ionizer Toshiba IAQ

•10 Times Faster Air Purifier •Many odors are removed in 30 

minutes

•Keeps you fresh with ions as 

found in nature

•Helps protect your home 

from pests and tobacco stains 

•Anti Virus* 

•Anti Bacteria** 

Super

 

Daiseikai

 

6.5

(9)

Self-cleaning function

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

(10)

6.5

Remote

 

Controller

 

with

 

backlight

 

display

Friendly

 

by

 

luminous

 

buttons

Toshiba new remote controller with luminous buttons 

delivering sorts of luxurious feeling and comfortable use.

The

 

biggest

 

screen

 

and

 

symbols

 

ever

The biggest screen and symbol ever are friendly 

to every user, especially to elder people.

8(5

13)

 

deg

 

C

 

in

 

heating

 

mode

  

(Holiday

 

feature)*

By running the air conditioner at low‐heat setting during the 

winter season, indoor temperature is kept about 8

°

C, 

reducing the change that water may freeze inside the pipes of 

the building. 

Power

 

select

 

mode*

The latest feature helps make today’s lifestyle more 

comfortable as it offers the benefit of saving electricity. 

POWER SEL* button, gives you the freedom to control power 

consumption of the air conditioner from a remote control by 

preventing high power operation. It helps you when you would 

like to avoid electricity black out, and need electricity for other 

appliances etc.

* Features are hidden in standard remote controller due to beinginapplicable with multi connection

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

(11)

1:1 and Multi application

Excluding 8°C holiday button and Excluding power select function

These 2 features are not available on IMS CDUs and therefore can not be left for B code

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

(12)

1:1 only

Including 8°C holiday button and Including power select function Possible as optional accessory

WH‐TA01JE

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

Remote

 

Control

(13)

New

 

Suzumi

 

plus

[RAS

BxxN3KV

E]

ƒ

TOSHIBA

 

Mid

tier

 

model

ƒ

New

 

modern

 

design

 

– Same as SDSK6.5 without „Daiseikai“logo, but „Inverter“

ƒ

Size

 

10,

 

13,

 

16

 

and

 

18

 

(for

 

single

 

only),

 

22

ƒ

Standard

 

model

 

white,

 

option

 

gray

 

panel

ƒ

B

Code

 

(same

 

model

 

for

 

single

 

and

 

multi

 

use)

– Single use, with Suzumi plus CDU, energy efficiency mid tier 

– Multi use with all current Multi CDU (M18, 3M26, 4M27, 5M34)

(14)

New

 

Suzumi

 

plus

[RAS

BxxN3KV

E]

Super

 

Daiseikai

 

6.5

[RAS

BxxN3KVP

E]

Option Paneel „SILVER“

To

 

be

 

ordered

 

seperately

Panel silver DSK 10‐16 43T09487 EUR 55,‐

Panel silver SUZ 10‐16 43T09485 EUR 55,‐

(15)
(16)

• CombiControl is a heat pump control by mobile phone

• CombiControlisdesigned to work with Toshiba air‐to‐air heat pumps*:

Daiseikai 3 Daiseikai 5Daiseikai 6Suzumi +AvAntConsole UFWKRTXT

– *Supported model range may be even wider depending on the 

remote control code. 

• CombiControlenables easily to adjust and control main functionsof a 

heat pump. 

• CombiControl can inform about low room temperature, power failures and service intervals.

(17)

The controller

IR LED signals LED 1 ‐Power

LED 2 ‐mobile phone LED LED 3 ‐IR LED

TEST button

RESET button

SIM card hole

Temperature  sensor Micro USB  adapter Size: 76x76mm Weight: 70g

(18)

Heat pump commands:

ƒ On/Off

ƒ Function setting, DRY / COOL / HEAT / AUTO ƒ Temperature setting, 16 ‐30 °C

ƒ Fan speed setting, min / norm / max

ƒ +8 function

Status request 

(includes heat pump function mode, fan speed mode, temperature mode, room 

temperature, power status etc)

Controller configuration 

(owner, users, default working modes, favorite heat pump settings)

(19)

Controller sends an alarm:

– If room temperature is low ( range 1‐16°C, default 5°C )

– No power ( range 1 – 48 hours , default 24h )

– Service time ( 1 – 360 days, default 180 days )

Controller status request

– (incl Heat pump status, last settings, room temperature, target temperature)

Controller version request

– (incl controller working time, firmware, power state, voltage, network signal 

(20)

1.Stronger IR LED lights

to make the signal stronger, more efficient and stable. Even with direct 

sunlight the signal will reach the indoor unit.

2.2 IR LED lights

CombiControl has 2 Infra Red LED’s to ensure that signals are delivered to 

heat pump each time.

3.Battery up to 36 hours

CombiControl has strong 1050 mAh Li‐ion battery (model BL‐5C for Nokia ) 

to ensure long stand by time if power loss encore.

4.Compact and modern design

only 76*76 mm of size and designed to match most heat pumps design.

5.Indoor temperature measuring

CombiControl has temperature sensor and therefore it is always possible to 

know the room’s indoor temperature (even if heat pump in off / not in 

use).

6.Easy to set up and use

CombiControl is very easy to set up and use. Just install the SIM card to 

your CombiControl, put the CombiControl anywhere near your heat pump, 

and you are ready!

7.More positioning possibilities in the room

CombiControl can be placed next to indoor unit / attached to indoor unit / 

on opposite wall of indoor unit / on a ledge, opposite to the indoor unit / 

(21)

8. Standard micro USB adapter

If needed client can replace standard adapter with another CE certified 

micro usb adapter (f.e. longer or other color adapter). 

9. Smartphone free APP or regular SMS

CombiControl can be used with all mobile phones.  Android / iPhone 

APP, also regular phone SMS. 

10. Compatible with most popular Toshibaheat pumps

CombiControl is easier to sell because it works with all most popular 

Toshibaheat pumps and therefore there’s no need for many similar 

products. 

11. Possible to add more models in future 

If enough demand CombiControl developers can add more models in the 

future

12. Alarm sending

if room temperature to low / if no power / if service time for heat pump

13. Produced and developed in EU, tested for Nordic countries

CombiControl is developed and produced in EU and has been testedin 

(22)

RAV

(23)

Digital

/Super

 

Digital

 

Hi

 

Wall

 

unit

 

series

 

6

RAV

SM566/806KRT

E

ƒ

New

 

design

‐Same design als VRF Hi Wall series 3

ƒ

New

 

IR

Control

 

included

 (incl.

 „Hi Power“, „Comfort Sleep“)

(24)

Digital

/Super

 

Digital

 

Duct

 

unit

 

series

 

6

RAV

SM566/806/1106/1406/1606BT

E

ƒ

Extended

 

model

 

range

 

(14/16

 

kW

Model)

ƒ

Compact

 

size

 

(only

 

275

 

height)

(25)

Operating modes: heating and fan only  (cooling notpermitted) Delivery date:  2‐3 weeks after from date of order

Developed in conjuction with Tekadoor GmbH ‐an established European air curtain manufacturer located in 

Germany

(26)

TOSHIBA Cassette TOSHIBA

Air Curtain

Typical Winter Operation

● Discharge Angled Outwards

● Air Curtain Heating

● Air Conditioning Heating

(27)

Typical Summer Operation

● Discharge Angled Inwards

● Air Curtain Fan Only

● Air Conditioning Cooling

TOSHIBA Air Curtain

TOSHIBA Cassette

Typical

 

Summer

  

Operation

(28)

RAV‐CT100/150/200/250CH‐M/L

DX Air Curtain Free‐Hanging (Medium/Large)

RAV‐CT100/150/200/250UH‐M/L

DX Air Curtain Cassette (Medium/Large)

RAV‐CT100/150/200/250BH‐M/L

(29)

2.

Manufacturing

 

techniques

A nitrogen (N2) purge is used for all brazing activities associated with the manufacture of the Toshiba air curtain. The 

N2 purge improves braze quality on the heat exchanger and reduces the potential of contamination in the 

refrigeration cycle

3.

Product

 

testing

Comprehensive performance and reliability testing, completed by Toshiba EMEA, to optimise the performance of the 

air curtain with the existing Toshiba LC range of outdoor units.The project was overseen by Toshiba Japan.

1.

Electrical

 

box

 

Integrateddesign giving the following advantages:

• Easy access for unit installation / maintenance

• Reduced installation time ‐No need to install separate DX kit

• Easier installation ‐‘DN Codes’factory set (Cooling Mode removed)

• Reduced installation costs – the electrical supply for the air curtain is taken from the CDU(no need 

for additional electrical supplies)

(30)

Product

 

Features

 

(cont

 ‐

1)

4.

3

 

Speed

 

fan

 

control

 

High, medium and low fan speeds available on the Toshiba air curtain. This allows the end user to change the air volume of the 

air curtain depending on site conditions.

The fan‐motors used in the Air Curtain comply with ErP 2013 (Commission Regulation (EU) No 327/2011).

5.

Defrost

 

tray

A defrost tray will be fitted to all Toshiba air curtains. During defrost cycles the Fan‐Motors continue to operate. 

Any moisture collected in the defrost tray evaporates when heating resumes.

6.

Flare

 

Nut

 

Fittings

(31)

Product

 

Features

 

(cont

 ‐

2)

7

.

CE

 

approval

The Toshiba air curtains will be supplied with CE Approval. 

The Declaration of Conformity will be displayed in the product literature

8.

Multi

 

language

 

literature

A multi language CD and a printed English manual will be supplied with each Toshiba air curtain. 

The manual will contain all details necessary for installing andoperating the air curtain correctly

9.

Custom

 

air

 

curtain

 

builds

Custom builds (different chassis colours, e‐box orientation etc) 

may be available depending on the complexity of the change request. Bespoked revolving doorsolutions are possible. Please contact  us to discuss your custom requirements.

(32)

Lead

 

time

 

and

 

prices

1.

Short

 

Lead

 

Times

Lead time, from receipt of order at AIR‐COND, is approximately 2‐3 weeks. The Toshiba air curtain will be delivered from 

Vienna storage to appropriate conditions of purchase.

2.

Prices

(33)

3

 

Air

 

Curtain

 

Models

 

(3

 

Styles)

Built‐in (BH)

Free‐Hanging (CH)

Cassette (UH)

Model Lineup

Available in 4 door widths:

•1,0m, 1,5m, 2,0m, & 2,5m 2 door height options:

•Medium (2,5m to 3,0m) •Large (2,7m to 3,2m)

Colour: White (RAL 9016)

Custom colours available on request

Model Door

Code Width M (Medium) L (Large)

CT100 1,0m 2,5m to 3,0m 2,7m to 3,2m

CT150 1,5m 2,5m to 3,0m 2,7m to 3,2m

CT200 2,0m 2,5m to 3,0m 2,7m to 3,2m

CT250 2,5m 2,5m to 3,0m 2,7m to 3,2m

(34)

Air

 

Curtain

 

Specifications

Model  Code Outdoor  Sizing hp Heating  Capacity  kW Air flow  rate  m3/h Power Input  Fan only  kW Door  Width  mm Max Door  Height  m Unit  Weight  kg Sound  Pressure  dBA RAV‐CT100CH‐L 3.0 8.0 2100 0.82 1000 3.2 57 55 RAV‐CT100CH‐M 3.0 8.0 1520 0.56 1000 3.0 54 54 RAV‐CT150CH‐L 4.0 11.2 2800 1.11 1500 3.2 87 56 RAV‐CT150CH‐M 4.0 11.2 2280 0.74 1500 3.0 85 55 RAV‐CT200CH‐L 5.0 14.0 4200 1.64 2000 3.2 117 57 RAV‐CT200CH‐M 5.0 14.0 3040 0.93 2000 3.0 115 56 RAV‐CT250CH‐L 6.0 16.0 4900 1.92 2500 3.2 149 58 RAV‐CT250CH‐M 6.0 16.0 3800 1.11 2500 3.0 147 57 Model  Code Outdoor  Sizing hp Heating  Capacity  kW Air flow  rate  m3/h Power Input  Fan only  kW Door  Width  mm Max Door  Height  m Unit  Weight  kg Sound  Pressure  dBA RAV‐CT100UH‐L 3.0 8.0 2100 0.82 1000 3.2 52 55 RAV‐CT100UH‐M 3.0 8.0 1520 0.56 1000 3.0 49 54 RAV‐CT150UH‐L 4.0 11.2 2800 1.11 1500 3.2 107 56 RAV‐CT150UH‐M 4.0 11.2 2280 0.74 1500 3.0 105 55 RAV‐CT200UH‐L 5.0 14.0 4200 1.64 2000 3.2 113 57 RAV‐CT200UH‐M 5.0 14.0 3040 0.93 2000 3.0 111 56 RAV‐CT250UH‐L 6.0 16.0 4900 1.92 2500 3.2 137 58 RAV‐CT250UH‐M 6.0 16.0 3800 1.11 2500 3.0 135 57 Model  Code Outdoor  Sizing hp Heating  Capacity  kW Air flow  rate  m3/h Power Input  Fan only  kW Door  Width  mm Max Door  Height  m Unit  Weight  kg Sound  Pressure  dBA RAV‐CT100BH‐L 3.0 8.0 2100 0.82 1000 3.2 80 55 RAV‐CT100BH‐M 3.0 8.0 1520 0.56 1000 3.0 77 54 RAV‐CT150BH‐L 4.0 11.2 2800 1.11 1500 3.2 115 56 RAV‐CT150BH‐M 4.0 11.2 2280 0.74 1500 3.0 113 55 RAV‐CT200BH‐L 5.0 14.0 4200 1.64 2000 3.2 145 57 RAV‐CT200BH‐M 5.0 14.0 3040 0.93 2000 3.0 143 56

(35)

Toshiba

 

Air

 

Curtain

 

/

 

CDU

 

Combinations

Compatible

 

in

 

1:1*

 

connection

 

with

 

Toshiba

 

DI

 

&

 

SDI

 

3

 

to

 

6HP

 

CDU:

* Note that twin and triple installations are not permitted.

Model Code  (CH / UH / BH) Door  Width (mm) Max Door  Height (m) Outdoor  DI Outdoor  SDI Outdoor  SDI (8)

RAV‐CT100**‐L 1000 3.2 RAV‐SM803AT‐E RAV‐SP804AT‐E RAV‐CT100**‐M 1000 3.0 RAV‐SM803AT‐E RAV‐SP804AT‐E

RAV‐CT150**‐L 1500 3.2 RAV‐SM1103AT‐E RAV‐SP1104AT‐E RAV‐SP1104AT8‐E RAV‐CT150**‐M 1500 3.0 RAV‐SM1103AT‐E RAV‐SP1104AT‐E RAV‐SP1104AT8‐E RAV‐CT200**‐L 2000 3.2 RAV‐SM1403AT‐E RAV‐SP1404AT‐E RAV‐SP1404AT8‐E RAV‐CT200**‐M 2000 3.0 RAV‐SM1403AT‐E RAV‐SP1404AT‐E RAV‐SP1404AT8‐E RAV‐CT250**‐L 2500 3.2 RAV‐SM1603AT‐E RAV‐SP1604AT‐E RAV‐SP1604AT8‐E RAV‐CT250**‐M 2500 3.0 RAV‐SM1603AT‐E RAV‐SP1604AT‐E RAV‐SP1604AT8‐E

(36)

Controls

 

and

 

Accessories

Control achieved using a Toshiba remote controller (NOT SUPPLIED) Optional Products

• TCB‐PCNT30TLE2 TCC‐Link interface connects to Toshiba BMS controls • TCB‐TC21LE2 Remote air sensor – in case of high ceiling.

• Ceiling mounting kit Vibration absorption / Sound isolation Î

RBC‐FDP3‐PE

(37)

VRF

(38)

Line‐up 

11 models

0.8/1.0/1.25/1.7/2.0/2.5/3.0/3.2/4.0/5.0/6.0 HP

VRF

•Available with wired RC RBC‐AMT32E, RBC‐AMS41E, and   

RBC‐AMS51E‐EN, ES

Available

Dec 2012

Features

•Slimmer design 275 mm hight

•Improved ex‐static pressure (max 120Pa) 

with new  DC Fan Motor

•The air suction direction can be altered from rear   

to bottom suction without any accessory

Model name MMD‐AP***6BH‐E HP 0.8 1 1.25 1.7 2 2.5 3 3.2 4 5 6 Cooling capacity(kW) 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 Heating capacity(kW) 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 Dimensions H 275 (mm) W 700 1000 1400 D 750 Weight (kg) 23 23 30 40

Static pressure High 120

(Pa) Std 30 40 50

Low 30

(39)

39

LINE‐UP

CONCEPT

Expand line‐up 

New capacities 2,5 HP and 3 HP

TARGET APPLICATIONS

Hotel, Office building, Residential

New line‐up: 2.5HP and 3HP 

HP 0.8 1.0 1.3 1.7 2.0 2.5 3.0

Cooling capacity(kW) 2.2 2.8 3.6 4.5 5.6 7.1 8

TOSHIBA ● ● ● ● ● ★ ★

MMD- SPH H210XW845XD645 H210XW1,140XD645

46/ 31/ 16/ 6Pa 45/ 30/ 15/ 5Pa 44/ 29/ 14/ 4Pa TBD

Model name:

MMD‐AP0244SPH‐E

MMD‐AP0274SPH‐E

Connectable CDU:      SMMS‐i/SHRM/MiNi‐SMMS

VRF Slim Duct

Available

(40)

SMART

 

Manager

with

 

data

 

analyzer

BMS

SM1280ETLE

Features:

• Central regulation for the calculation of energy 

costs 

• Data will be saved on a Micro‐SD card

• Graphical display of the energy consumption

• Temperature limits adjustable

(41)
(42)

Products

Products

Preview

 

2013

Preview

 

2013

(43)

Super Daiseikai 6.5 [RAS‐B10/13/16N3KVP‐E] Super Daiseikai 6 [RAS‐10/13/16SKVP2‐E] Suzumi Plus [RAS‐B10/13/16/18/22N3KV2‐E] [RAS‐BxxUFV‐E] Suzumi Plus [RAS‐10/13/16/18/22SKV2‐E] AvAnt

[RAS‐107SKV‐E4] .. To match EuP Lot10 [RAS‐137/167SKV‐E3]

Fix Speed

[RAS‐10/13/18/24SKHP‐ES2]

‐‐Phase out ‐‐

RAS

 

Single

 ‐

Line

 

Up

 

2013

C

 

O

 

P

High

 

Tier

        

Mid

 

Tier

      

Entry

 

Tier

New Entry tier Inverter

[RAS‐077N3KV‐E, RAS‐107N3KV‐E, RAS‐137N3KV‐E, size 16 tbc] In accordance with EuP Lot10

(44)

New Products 2013

• VRF hot water module (low temperature)

‐ Target Q2 2012

• ESTIA Series 4 (Apr 2013)

‐ A Class pump +ErP Lot 11 Compliance

‐ Water temp 7°c  in Cooling mode

• New Touch Screen Controller (demo version on 

Chillventa Nuremberg Oct 2012)

References

Related documents

Calculation of the minimum L/V ratio (given initial and final purities) Determine a realistic operating line.. Perform McCabe-Thiele analysis to find the number of

 Popular People with Disabilities, 2012 Vocational Rehabilitation Association of Canada’s 2012 Summer Edition of their Rehabilitation Matters Magazine & 2012 Summer Edition of

MODEL 9923 Hydraulic Specifications Ingressi idraulici Hydraulic ports Diametro nominale Nominal diameter DN - [mm] DN - [mm] Olio Fluid. Velocità di

Similar activities have emerged elsewhere, suggesting wider, nascent potential (e.g. In this paper, we analyse the results of a user study of a prototype

investigated the live kidney donor cohort in our center from 2001 until 2005 regarding vascular multiplicity, showing that despite an increased warm ischemia time, operation time

Lenzilumab is the first and only COVID-19 therapy to improve ventilator-free survival when added to other treatments, including steroids and/or remdesivir, in a

The effort to eliminate trans fatty acids in margarine strongly reduced or even eliminated the use of (trans-containing) partially hydrogenated oils/fats as solid fat phase

Well- organized historical data before the application service managers’ requests could shorten the transition times which surveys on current monitoring tasks for