10/27/2020
RELIABILITY MONITOR REPORT
FOR
MFN S18
MAXIM INTEGRATED
160 RIO ROBLES
SAN JOSE, CA 95134
This Report was prepared by
Summary:
The data in the tables that follow was generated as the result of an on-going Process Reliability
Monitor. The specific products in this process monitor are:
The calculated failure rate for devices using this process is:
The reliability data follows and in this section is the detailed reliability data by stress. The reliability
data section includes the latest data available. This report covers data between
and .
7/1/2020
9/30/2020
The parameters used to calculate this failure rate are as follows:
Cf: 60%
Ea: 0.7
Tu: 25
°C
Process Description:
MFN S18
Process Information:
MAX14906ATM
MAX16160UCA
MAX16936RATE
MAX16993ATJA
MAX17227AAN
MAX17270ENE+
MAX17291ANT+
MAX17690ATE/
MAX17761XAT
MAX20006EAFO
MAX20006FOA/
MAX20006FOQ/
MAX20011BAFO
MAX20024AXG/
MAX20024CGX
MAX20024GGX
MAX20025MGX
MAX20028ATJA
MAX20029ATID/
MAX20030BAT
MAX20040BATP
MAX20049ATEA
MAX20049ATEB
MAX20069BGTL
MAX20081ATN
MAX20098ATEA
MAX20323FENC
MAX20340EWL
MAX20361AEW
MAX20411CAFH
MAX20428ATIA/
MAX20429AAF
MAX20430ATIA/
MAX20471ASA
MAX22088GTG+
MAX22246CAW
MAX22518AWA
MAX22700DAS
MAX25024ATG/
MAX25206ATPA
MAX25249ATPC
MAX25300AAT
MAX25430AATL
MAX30208
MAX30208CLB+
MAX31343EKA+
MAX31343ETAY
MAX31343ETAY
MAX31345GTA/
MAX31825ANT+
MAX31875R2TZ
MAX31889ALT+
MAX33012EASA
MAX33040EAK
MAX33054EASA
MAX40009ANT+
MAX40100ANT+
MAX44248ASA+
MAX44281OAN
MAX44284FAZT
MAX44284FAZT
MAX44290ANT+
MAX49140AXK/
MAX77597ETBB
MAX86146CFU+
MAX86171ENI+
MAX98357AETE
MAX98360BENL
MAXM25265AL
FITS: 0.2
MTTF (YRS): 651125
FAILURE RATE:
QUANTITY: 5162
FAILS: 0
OPERATING LIFE
DESCRIPTION DATE CONDITION READPOINT QUANTITY FAILS CODE TEST VEHICLE LOT NO. 1000 125°C 79 0
HIGH TEMP OP LIFE MAX17761XATC+ HRS JBZO0Q003A
1000
125°C 41 0
HIGH TEMP OP LIFE MAX86146CFU+ HRS BCUS1AB
1000
125°C 45 0
HIGH TEMP OP LIFE MAX86146CFU+ HRS BCUS1AC
1000
125°C 44 0
HIGH TEMP OP LIFE MAX86146CFU+ HRS BCUS1AD
192
125°C 80 0
HIGH TEMP OP LIFE MAX30208 HRS JCUG4Q002KF
1000
125°C 80 0
HIGH TEMP OP LIFE MAX40009ANT+ HRS JBNB4A006A
1000
125°C 80 0
HIGH TEMP OP LIFE MAX20323FENC+T HRS JBYY9A031B
192
125°C 80 0
HIGH TEMP OP LIFE MAX20340EWL+ HRS JCCC9Q001DX
1000
125°C 79 0
HIGH TEMP OP LIFE 1826 MAX17761XATC+ HRS JBZO0Q001S
1000
125°C 80 0
HIGH TEMP OP LIFE 1827 MAX20024AXG/V+CQK HRS JBSI93020DA
1000
125°C 36 0
HIGH TEMP OP LIFE 1840 MAX20040BATPA/VY+ HRS JCUE0Q001V
1000
125°C 80 0
192
125°C 28 0
HIGH TEMP OP LIFE 1903 MAX20011BAFOA/VY+ HRS JCUK0Q001FQ
2000
125°C 80 0
HIGH TEMP OP LIFE 1904 MAX20029ATID/V+ HRS JBQA5A005B
500
125°C 80 0
HIGH TEMP OP LIFE 1908 MAX40100ANT+T HRS JCUW1Q003AK
192
125°C 79 0
HIGH TEMP OP LIFE 1908 MAX17270ENE+T HRS JCTK7A009C
1000
125°C 80 0
HIGH TEMP OP LIFE 1909 MAX31875R2TZS+T HRS JBZG42005O
1000
125°C 80 0
HIGH TEMP OP LIFE 1912 MAX44248ASA+ HRS JCTZ7Q001F
1000
125°C 79 0
HIGH TEMP OP LIFE 1918 MAX20098ATEAK/VY+ HRS JBTD3A008BB
288
125°C 80 0
HIGH TEMP OP LIFE 1918 MAX22518AWA+ HRS NCUW5ADQ
500
125°C 25 0
HIGH TEMP OP LIFE 1919 MAX20011BAFOA/VY+ HRS JCBO5Q001O#
1000
125°C 80 0
HIGH TEMP OP LIFE 1919 MAX44281OANS+T HRS JBVF5A007AG
192
125°C 80 0
HIGH TEMP OP LIFE 1924 MAX17690ATE/V+ HRS JCBE5Q001EQ
1000
125°C 80 0
HIGH TEMP OP LIFE 1925 MAX20081ATNK/V+ HRS JBSM83085A
1000
125°C 79 0
HIGH TEMP OP LIFE 1925 MAX20081ATNK/V+ HRS JBSM83085AB
1000
125°C 80 0
HIGH TEMP OP LIFE 1925 MAX20081ATNK/V+ HRS JBSM83085AA
192
125°C 80 0
HIGH TEMP OP LIFE 1931 MAX14906ATM+ HRS JCBM5Q001TQ
1000
125°C 79 0
HIGH TEMP OP LIFE 1933 MAX31343EKA+T HRS JCDF13001K
1000
125°C 80 0
HIGH TEMP OP LIFE 1936 MAX31343EKA+T HRS JCDF1Q002CA
192
125°C 80 0
HIGH TEMP OP LIFE 1936 MAX20430ATIA/VY+ HRS JCDD33002VQ
1000
125°C 80 0
HIGH TEMP OP LIFE 1939 MAX33054EASA+ HRS JBSL73004BX
192
125°C 80 0
HIGH TEMP OP LIFE 1939 MAX33012EASA+ HRS JCDS7Q001BQ
1000
125°C 77 0
HIGH TEMP OP LIFE 1940 MAX44284FAZT+ HRS JCAG13033D
1000
125°C 77 0
HIGH TEMP OP LIFE 1940 MAX44284FAZT+ HRS JCAG13033B
1000
125°C 77 0
HIGH TEMP OP LIFE 1940 MAX44284FAZT+ HRS JCAG13033C
192
125°C 80 0
HIGH TEMP OP LIFE 1940 MAX25024ATG/V+ HRS JCDF33001KQ
1000
125°C 80 0
HIGH TEMP OP LIFE 1941 MAX40009ANT+ HRS JBNB4A005A
192
125°C 80 0
HIGH TEMP OP LIFE 1944 MAX25249ATPC/VY+ HRS JCBA7Q001AA
1000
125°C 80 0
HIGH TEMP OP LIFE 1944 MAX16160UCAB+T HRS JCBA9Q001RD
192
125°C 80 0
HIGH TEMP OP LIFE 1946 MAX31825ANT+ HRS KW209078AAX
192
125°C 80 0
HIGH TEMP OP LIFE 1946 MAX17291ANT+ HRS JCEH03001HQ
288
125°C 79 0
HIGH TEMP OP LIFE 1947 MAX22088GTG+ HRS JCDC9Q001TQ
1000
125°C 80 0
HIGH TEMP OP LIFE 1949 MAX31343EKA+T HRS JCDF1Q003AB
192
125°C 80 0
HIGH TEMP OP LIFE 1950 MAX20430ATIA/VY+ HRS JCDD33003D
1000
125°C 79 0
HIGH TEMP OP LIFE 2001 MAX49140AXK/V+T HRS JCEC4Q001CA
1000
125°C 80 0
HIGH TEMP OP LIFE 2001 MAX49140AXK/V+T HRS JCEC4Q001CB
1000
125°C 78 0
HIGH TEMP OP LIFE 2001 MAX49140AXK/V+T HRS JCEC4Q001CC
192
125°C 80 0
1000
125°C 84 0
HIGH TEMP OP LIFE 2005 MAX77597ETBB+ HRS JCAN83001J
192
125°C 80 0
HIGH TEMP OP LIFE 2005 MAX22700DASA+ HRS BBYN7AQ
192
125°C 80 0
HIGH TEMP OP LIFE 2007 MAX17227AANT+ HRS JCFH1Q001IX
1000
125°C 80 0
HIGH TEMP OP LIFE 2008 MAX44290ANT+ HRS TBFD4A005AE
192
125°C 80 0
HIGH TEMP OP LIFE 2009 MAX22246CAWA+ HRS BCEO0AGQ
500
125°C 80 0
HIGH TEMP OP LIFE 2011 MAX44290ANT+ HRS TBFD4A006AG
1000
125°C 80 0
HIGH TEMP OP LIFE 2011 MAX44290ANT+ HRS JCFR1Q003OE
192
125°C 80 0
HIGH TEMP OP LIFE 2013 MAX20361AEWC HRS JCGQ13001IK
1000
125°C 80 0
HIGH TEMP OP LIFE 2014 MAX44290ANT+ HRS JCFR1A004AG
1000
125°C 80 0
HIGH TEMP OP LIFE 2014 MAX44290ANT+ HRS JCFR1A006B
192
125°C 80 0
HIGH TEMP OP LIFE 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001JP
192
125°C 80 0
HIGH TEMP OP LIFE 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001KP
192
125°C 80 0
HIGH TEMP OP LIFE 2015 MAX20411CAFHA/VY+ HRS JCFO9Q001RP
192
125°C 80 0
HIGH TEMP OP LIFE 2015 MAX25206ATPA/VY+ HRS JCFU7Q001GX
192
125°C 80 0
HIGH TEMP OP LIFE 2017 MAX25430AATLF/V+ HRS JCGC0Q001JQ
192
125°C 78 0
HIGH TEMP OP LIFE 2017 MAX25300AATA/V+T HRS JCCM4Q001LD
1000
125°C 80 0
HIGH TEMP OP LIFE 2017 MAX16993ATJA/V+ HRS JBSH2A115AA
500
125°C 80 0
HIGH TEMP OP LIFE 2018 MAX16160UCAB+T HRS JCBA9Q001SC
192
125°C 80 0
HIGH TEMP OP LIFE 2018 MAX20429AAFNA/VY+ HRS JCER9Q002NX
192
125°C 80 0
HIGH TEMP OP LIFE 2026 MAX20069BGTLA/V+ HRS JCFZ1A023FQ 0
Total:
STORAGE LIFE
DESCRIPTION DATE CONDITION READPOINT QUANTITY FAILS CODE TEST VEHICLE LOT NO. 1000 150°C 80 0
STORAGE LIFE MAX86146CFU+ HRS BCUS1AB
1000
150°C 80 0
STORAGE LIFE MAX86146CFU+ HRS BCUS1AC
1000
150°C 80 0
STORAGE LIFE MAX86146CFU+ HRS BCUS1AD
1000
150°C 80 0
STORAGE LIFE MAX40009ANT+ HRS JBNB4A006A
1000
150°C 80 0
STORAGE LIFE MAX20323FENC+T HRS JBYY9A031B
1000
150°C 77 0
STORAGE LIFE 1711 MAX20006FOA/VY+ HRS JBNE5Q003B
1000
150°C 77 0
STORAGE LIFE 1711 MAX20006FOA/VY+ HRS JBNE5Q003BA
500
150°C 80 0
STORAGE LIFE 1843 MAX40100ANT+T HRS JCUW1Q001SE
500
150°C 80 0
STORAGE LIFE 1843 MAX40100ANT+T HRS JCUW1Q002AF
1000
150°C 80 0
STORAGE LIFE 1908 MAX17270ENE+T HRS JCTK7A009C
1000
150°C 80 0
STORAGE LIFE 1911 MAX98357AETE+ HRS JP1566227SX
1000
150°C 83 0
STORAGE LIFE 1915 MAX20025MGXXB/V+ HRS JBSI93034R
500
150°C 80 0
1000
150°C 25 0
STORAGE LIFE 1916 MAX20024GGXXC/V+ HRS JBSI9A164AX
1000
150°C 79 0
STORAGE LIFE 1917 MAX31889ALT+T HRS JCUG4Q003BD
1000
150°C 79 0
STORAGE LIFE 1917 MAX20098ATEAK/VY+ HRS JBTD3A008BA
2000
150°C 78 0
STORAGE LIFE 1917 MAX20098ATEAK/VY+ HRS JBTD3A008BA
2000
150°C 78 0
STORAGE LIFE 1917 MAX20098ATEAK/VY+ HRS JBTD3A008BC
2000
150°C 79 0
STORAGE LIFE 1918 MAX20098ATEAK/VY+ HRS JBTD3A008BB
1000
150°C 80 0
STORAGE LIFE 1919 MAX44281OANS+T HRS JBVF5A007AG
2000
150°C 30 0
STORAGE LIFE 1924 MAX20006EAFOD/VY+ HRS JCAS5Q002LX
1000
150°C 80 0
STORAGE LIFE 1925 MAX20081ATNK/V+ HRS JBSM83085A
1000
150°C 80 0
STORAGE LIFE 1925 MAX20081ATNK/V+ HRS JBSM83085AB
1000
150°C 80 0
STORAGE LIFE 1925 MAX20081ATNK/V+ HRS JBSM83085AA
1000
150°C 79 0
STORAGE LIFE 1932 MAX31889ALT+T HRS JCUG4Q003BE
1000
150°C 77 0
STORAGE LIFE 1932 MAX31889ALT+T HRS JCUG4Q003BF
1000
150°C 80 0
STORAGE LIFE 1933 MAX31343EKA+T HRS JCDF13001K
1000
150°C 80 0
STORAGE LIFE 1936 MAX31343EKA+T HRS JCDF1Q002CA
1000
150°C 80 0
STORAGE LIFE 1937 MAX31343ETAY+ HRS JCDF1Q002D
1000
150°C 80 0
STORAGE LIFE 1937 MAX31343ETAY+T HRS JCDF1Q002A
1000
150°C 80 0
STORAGE LIFE 1937 MAX31343ETAY+T HRS JCDF1Q003B
1000
150°C 80 0
STORAGE LIFE 1937 MAX31345GTA/VY+ HRS JCDF1Q002DH
1000
150°C 80 0
STORAGE LIFE 1939 MAX33054EASA+ HRS JBSL73004BX
1000
150°C 77 0
STORAGE LIFE 1940 MAX44284FAZT+ HRS JCAG13033D
1000
150°C 77 0
STORAGE LIFE 1940 MAX44284FAZT+ HRS JCAG13033B
1000
150°C 77 0
STORAGE LIFE 1940 MAX44284FAZT+ HRS JCAG13033C
1000
150°C 80 0
STORAGE LIFE 1941 MAX40009ANT+ HRS JBNB4A005A
1000
150°C 146 0
STORAGE LIFE 1942 MAXM25265ALN/V+ HRS JCBT93001DB
192
150°C 240 0
STORAGE LIFE 1942 MAXM25265ALN/V+ HRS JCBT93001DB
1000
150°C 80 0
STORAGE LIFE 1942 MAXM25265ALN/V+ HRS JCBT93001DA
96
150°C 80 0
STORAGE LIFE 1942 MAXM25265ALN/V+ HRS JCBT93001DA
1000
150°C 80 0
STORAGE LIFE 1944 MAX16160UCAB+T HRS JCBA9Q001RD
1000
150°C 80 0
STORAGE LIFE 1945 MAX20024CGXXE/V+ HRS JBSI93236EX
1000
150°C 79 0
STORAGE LIFE 1949 MAX31343EKA+T HRS JCDF1Q003AB
500
150°C 80 0
STORAGE LIFE 1950 MAX20430ATIA/VY+ HRS JCDD33003D
1000
150°C 80 0
STORAGE LIFE 2001 MAX49140AXK/V+T HRS JCEC4Q001CA
1000
150°C 80 0
STORAGE LIFE 2001 MAX49140AXK/V+T HRS JCEC4Q001CB
1000
150°C 80 0
STORAGE LIFE 2001 MAX49140AXK/V+T HRS JCEC4Q001CC
500
150°C 80 0
1000
150°C 79 0
STORAGE LIFE 2005 MAX77597ETBB+ HRS JCAN83001J
1000
150°C 80 0
STORAGE LIFE 2008 MAX44290ANT+ HRS TBFD4A005AE
1000
150°C 80 0
STORAGE LIFE 2011 MAX44290ANT+ HRS TBFD4A006AG
1000
150°C 80 0
STORAGE LIFE 2011 MAX44290ANT+ HRS JCFR1Q003OE
1000
150°C 80 0
STORAGE LIFE 2014 MAX44290ANT+ HRS JCFR1A004AG
1000
150°C 80 0
STORAGE LIFE 2014 MAX44290ANT+ HRS JCFR1A006B
1000
150°C 80 0
STORAGE LIFE 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001JP
1000
150°C 80 0
STORAGE LIFE 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001KP
500
150°C 80 0
STORAGE LIFE 2015 MAX20411CAFHA/VY+ HRS JCFO9Q001RP
1000
150°C 80 0
STORAGE LIFE 2017 MAX16993ATJA/V+ HRS JBSH2A115AA
0 Total:
TEMPERATURE CYCLE
DESCRIPTION DATE CONDITION READPOINT QUANTITY FAILS CODE TEST VEHICLE LOT NO. 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS MAX86146CFU+ BCUS1AB 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS MAX86146CFU+ BCUS1AC 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS MAX86146CFU+ BCUS1AD 3500 -65C TO +150C (Condition C) 77 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1711 MAX20006FOA/VY+ JBNE5Q003B 3500 -65C TO +150C (Condition C) 77 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1711 MAX20006FOQ/VY+ JBNE5Q003BB 3500 -65C TO +150C (Condition C) 76 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1711 MAX20006FOA/VY+ JBNE5Q003BA 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1803 MAX16936RATEA/V+CU TAQT1A045F 1000 -65C TO +150C (Condition C) 72 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1810 MAX20049ATEA/VY+ JBYR1Q001MB 1000 -65C TO +150C (Condition C) 73 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1812 MAX20049ATEA/VY+ JBYR1Q001LI 1000 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1850 MAX44284FAZT+ JCAG1A005KB 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1912 MAX44248ASA+ JCTZ7Q001F 1000 -40C TO +125C (Condtion B) 25 0 TEMP CYCLE, 0' RAMP,
10' DWELL
CYS
500 -65C TO
+150C (Condition C)
80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1916 MAX20025MGXXB/V+ JBSI93034RB 1000 -65C TO +150C (Condition C) 25 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1916 MAX20024GGXXC/V+ JBSI9A164AX 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1917 MAX31889ALT+T JCUG4Q003BD 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1917 MAX20098ATEAK/VY+ JBTD3A008BC 2000 -65C TO +150C (Condition C) 72 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1917 MAX20098ATEAK/VY+ JBTD3A008BA 2000 -65C TO +150C (Condition C) 73 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1917 MAX20098ATEAK/VY+ JBTD3A008BC 1000 -40C TO +125C (Condtion B) 46 0 TEMP CYCLE, 0' RAMP,
10' DWELL CYS 1918 MAX20081ATNK/V+ JBSM83078BA 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1918 MAX20098ATEAK/VY+ JBTD3A008BB 2000 -65C TO +150C (Condition C) 68 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1918 MAX20098ATEAK/VY+ JBTD3A008BB 850 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1919 MAX98360BENL+T JCBK6Q001F 850 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1919 MAX44281OANS+T JBVF5A007AG 850 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1920 MAX98360BENL+T JCBK6Q001G 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1923 MAX98360BENL+T JCBK6Q001H 2000 -65C TO +150C (Condition C) 73 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1925 MAX20081ATNK/V+ JBSM83085A 2000 -65C TO +150C (Condition C) 73 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1925 MAX20081ATNK/V+ JBSM83085AB 2000 -65C TO +150C (Condition C) 73 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1925 MAX20081ATNK/V+ JBSM83085AA 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1926 MAX98357AETE+ JBTS83630AA 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1932 MAX31889ALT+T JCUG4Q003BE 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL
CYS
100 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1933 MAX44284FAZT+TG7 JCAG13048BG 100 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1933 MAX44284FAZT+TG7 JCAG13037BA 850 -40C TO +125C (Condtion G) 78 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1933 MAX31343EKA+T JCDF13001K 100 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1934 MAX44284FAZT+TG7 JCAG13046BI 100 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1934 MAX44284FAZT+TG7 JCAG13047AH 850 -40C TO +125C (Condtion G) 79 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1936 MAX31343EKA+T JCDF1Q002CA 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1937 MAX31343ETAY+ JCDF1Q002D 100 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1939 MAX44284FAZT+TG7 JCAG13050AJ 100 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1940 MAX44284FAZT+TG7 JCAG13033A 1000 -40C TO +125C (Condtion B) 77 0 TEMP CYCLE, 0' RAMP,
10' DWELL CYS 1940 MAX44284FAZT+ JCAG13033D 1000 -40C TO +125C (Condtion B) 77 0 TEMP CYCLE, 0' RAMP,
10' DWELL CYS 1940 MAX44284FAZT+ JCAG13033B 1000 -40C TO +125C (Condtion B) 77 0 TEMP CYCLE, 0' RAMP,
10' DWELL CYS 1940 MAX44284FAZT+ JCAG13033C 1000 -65C TO +150C (Condition C) 240 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1942 MAXM25265ALN/V+ JCBT93001DB 1000 -65C TO +150C (Condition C) 150 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1942 MAXM25265ALN/V+ JCBT93001DB 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1944 MAX16160UCAB+T JCBA9Q001RD 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1945 MAX20024CGXXE/V+ JBSI93236EX 850 -40C TO +125C (Condtion G) 80 0 TEMP CYCLE, 15' RAMP, 15' DWELL CYS 1949 MAX31343EKA+T JCDF1Q003AB 1000 -65C TO +150C (Condition C) 90 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 1950 MAX20430ATIA/VY+ JCDD33003D 1000 -65C TO +150C (Condition C) 79 0 TEMP CYCLE, 5' RAMP,
10' DWELL
CYS
1000 -65C TO
+150C (Condition C)
77 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001CB 1000 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001CC 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001C 500 -65C TO +150C (Condition C) 79 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001C 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001C 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001C 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2001 MAX49140AXK/V+T JCEC4Q001C 500 -65C TO +150C (Condition C) 90 0 TEMP CYCLE, 5' RAMP,
10' DWELL
CYS
2005 MAX20430ATIA/VY+ JCDD33003G
850 80 0
TEMP CYCLE, 0' RAMP, 10' DWELL
CYS
2008 MAX44290ANT+ TBFD4A005AE
850 80 0
TEMP CYCLE, 0' RAMP, 10' DWELL CYS 2011 MAX44290ANT+ TBFD4A006AG 1500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2015 MAX20411CAFHA/VY+ JCFO8Q001JP 1500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2015 MAX20411CAFHA/VY+ JCFO8Q001KP 1500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2015 MAX20411CAFHA/VY+ JCFO9Q001RP 500 -65C TO +150C (Condition C) 80 0 TEMP CYCLE, 5' RAMP,
10' DWELL CYS 2017 MAX16993ATJA/V+ JBSH2A115AA 500 -65C TO +150C (Condition C) 100 0 TEMP CYCLE, 5' RAMP,
10' DWELL
CYS
2018 MAX16160UCAB+T JCBA9Q001SB
0 Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION DATE CONDITION READPOINT QUANTITY FAILS CODE TEST VEHICLE LOT NO. 1000 85 C/85% R.H. 45 0
BIASED MOISTURE MAX86146CFU+ HRS BCUS1AB
1000
85 C/85% R.H. 45 0
BIASED MOISTURE MAX86146CFU+ HRS BCUS1AC
1000
85 C/85% R.H. 45 0
BIASED MOISTURE MAX86146CFU+ HRS BCUS1AD
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1637 MAX40009ANT+ HRS JBNB4Q001B
96
130C, 85% R.H. 80 0
192
130C, 85% R.H. 78 0
BIASED MOISTURE 1832 MAX20049ATEB/VY+ HRS JBYR1Q001CF
96
130C, 85% R.H. 83 0
BIASED MOISTURE 1846 MAX20028ATJA/VY+ HRS JCTJ1Q002RC
192
130C, 85% R.H. 62 0
BIASED MOISTURE 1851 MAX20030BATMK/V+ HRS TBSH7A028HA
192
130C, 85% R.H. 69 0
BIASED MOISTURE 1851 MAX20030BATMK/V+ HRS TBSH7A028HB
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1908 MAX17270ENE+T HRS JCTK7A009C
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1916 MAX44284FAZT+TG7 HRS JCAG13014A
96
130C, 85% R.H. 79 0
BIASED MOISTURE 1917 MAX20098ATEAK/VY+ HRS JBTD3A008BA
192
130C, 85% R.H. 72 0
BIASED MOISTURE 1917 MAX20098ATEAK/VY+ HRS JBTD3A008BA
192
130C, 85% R.H. 72 0
BIASED MOISTURE 1917 MAX20098ATEAK/VY+ HRS JBTD3A008BC
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1918 MAX20081ATNK/V+ HRS JBSM83078B
192
130C, 85% R.H. 78 0
BIASED MOISTURE 1918 MAX20081ATNK/V+ HRS JBSM83078B
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1918 MAX20081ATNK/V+ HRS JBSM83078BA
192
130C, 85% R.H. 80 0
BIASED MOISTURE 1918 MAX20081ATNK/V+ HRS JBSM83078BA
192
130C, 85% R.H. 79 0
BIASED MOISTURE 1918 MAX20081ATNK/V+ HRS JBSM83078BB
192
130C, 85% R.H. 70 0
BIASED MOISTURE 1918 MAX20098ATEAK/VY+ HRS JBTD3A008BB
96
130C, 85% R.H. 73 0
BIASED MOISTURE 1919 MAX33040EAKA+T HRS JCBI9Q001CC
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1919 MAX44281OANS+T HRS JBVF5A007AG
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1923 MAX98360BENL+T HRS JCBK6Q001H
192
130C, 85% R.H. 73 0
BIASED MOISTURE 1925 MAX20081ATNK/V+ HRS JBSM83085A
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1925 MAX20081ATNK/V+ HRS JBSM83085AB
192
130C, 85% R.H. 80 0
BIASED MOISTURE 1925 MAX20081ATNK/V+ HRS JBSM83085AB
192
130C, 85% R.H. 73 0
BIASED MOISTURE 1925 MAX20081ATNK/V+ HRS JBSM83085AA
96
130C, 85% R.H. 77 0
BIASED MOISTURE 1932 MAX31889ALT+T HRS JCUG4Q003BE
96
130C, 85% R.H. 77 0
BIASED MOISTURE 1932 MAX31889ALT+T HRS JCUG4Q003BF
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1933 MAX31343EKA+T HRS JCDF13001K
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1936 MAX31343EKA+T HRS JCDF1Q002CA
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1937 MAX31343ETAY+ HRS JCDF1Q002D
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1937 MAX31343ETAY+T HRS JCDF1Q002A
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1937 MAX31343ETAY+T HRS JCDF1Q003B
264
130C, 85% R.H. 77 0
BIASED MOISTURE 1940 MAX44284FAZT+ HRS JCAG13033D
264
130C, 85% R.H. 77 0
BIASED MOISTURE 1940 MAX44284FAZT+ HRS JCAG13033C
96
130C, 85% R.H. 79 0
BIASED MOISTURE 1944 MAX16160UCAB+T HRS JCBA9Q001RD
264
130C, 85% R.H. 80 0
BIASED MOISTURE 1949 MAX31343EKA+T HRS JCDF1Q003AB
96
130C, 85% R.H. 80 0
BIASED MOISTURE 1950 MAX20430ATIA/VY+ HRS JCDD33003D
96
130C, 85% R.H. 80 0
BIASED MOISTURE 2001 MAX49140AXK/V+T HRS JCEC4Q001CA
96
130C, 85% R.H. 79 0
192
130C, 85% R.H. 73 0
BIASED MOISTURE 2001 MAX49140AXK/V+T HRS JCEC4Q001CC
96
130C, 85% R.H. 61 0
BIASED MOISTURE 2005 MAX20430ATIA/VY+ HRS JCDD33003G
264
130C, 85% R.H. 80 0
BIASED MOISTURE 2008 MAX44290ANT+ HRS TBFD4A005AE
264
130C, 85% R.H. 80 0
BIASED MOISTURE 2011 MAX44290ANT+ HRS TBFD4A006AG
96
130C, 85% R.H. 80 0
BIASED MOISTURE 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001JP
96
130C, 85% R.H. 80 0
BIASED MOISTURE 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001KP
96
130C, 85% R.H. 80 0
BIASED MOISTURE 2015 MAX20411CAFHA/VY+ HRS JCFO9Q001RP
96
130C, 85% R.H. 40 0
BIASED MOISTURE 2017 MAX16993ATJA/V+ HRS JBSH2A115AA
96
130C, 85% R.H. 40 0
BIASED MOISTURE 2017 MAX16993ATJA/V+ HRS JBSH2A115AA 0
Total:
UNBIASED MOISTURE RESISTANCE
DESCRIPTION DATE CONDITION READPOINT QUANTITY FAILS CODE TEST VEHICLE LOT NO. 96 130C, 85% R.H. 80 0
MOISTURE SOAK MAX86171ENI+ HRS JCUL3Q003GM
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1827 MAX20323FENC+T HRS JBYY9A012HB
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1907 MAX44284FAZT+TG7 HRS JCAG1A009AK
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1911 MAX98357AETE+ HRS JP1566227SX
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1919 MAX44281OANS+T HRS JBVF5A007AG
96
130C, 85% R.H. 30 0
MOISTURE SOAK 1924 MAX20006EAFOD/VY+ HRS JCAS5Q002LX
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1925 MAX20081ATNK/V+ HRS JBSM83085A
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1925 MAX20081ATNK/V+ HRS JBSM83085AA
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1933 MAX44284FAZT+TG7 HRS JCAG13048BG
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1933 MAX44284FAZT+TG7 HRS JCAG13037BA
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1933 MAX31343EKA+T HRS JCDF13001K
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1934 MAX44284FAZT+TG7 HRS JCAG13047AH
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1936 MAX31343EKA+T HRS JCDF1Q002CA
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1937 MAX31343ETAY+ HRS JCDF1Q002D
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1937 MAX31343ETAY+T HRS JCDF1Q002A
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1937 MAX31343ETAY+T HRS JCDF1Q003B
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1939 MAX44284FAZT+TG7 HRS JCAG13050AJ
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1940 MAX44284FAZT+TG7 HRS JCAG13033A
96
130C, 85% R.H. 77 0
MOISTURE SOAK 1940 MAX44284FAZT+ CYS JCAG13033D
96
130C, 85% R.H. 77 0
MOISTURE SOAK 1940 MAX44284FAZT+ CYS JCAG13033B
96
130C, 85% R.H. 77 0
MOISTURE SOAK 1940 MAX44284FAZT+ CYS JCAG13033C
96
130C, 85% R.H. 240 0
MOISTURE SOAK 1942 MAXM25265ALN/V+ HRS JCBT93001DB
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1944 MAX16160UCAB+T CYS JCBA9Q001RD
96
130C, 85% R.H. 80 0
96
130C, 85% R.H. 80 0
MOISTURE SOAK 1950 MAX20430ATIA/VY+ HRS JCDD33003D
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2001 MAX49140AXK/V+T HRS JCEC4Q001CA
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2001 MAX49140AXK/V+T HRS JCEC4Q001CB
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2001 MAX49140AXK/V+T HRS JCEC4Q001CC
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2008 MAX44290ANT+ HRS TBFD4A005AE
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2011 MAX44290ANT+ HRS TBFD4A006AG
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001JP
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2015 MAX20411CAFHA/VY+ HRS JCFO8Q001KP
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2015 MAX20411CAFHA/VY+ HRS JCFO9Q001RP
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2018 MAX16160UCAB+T HRS JCBA9Q001SC
96
130C, 85% R.H. 80 0
MOISTURE SOAK 2018 MAX16160UCAB+T HRS JCBA9Q001SB
0 Total:
FITS: 0.2