User Guide

100-Base-FX

Network Interface Cards (NICs)

Introduction

Transition Networks’ N-FX-xx-03 PCI 100FX NICs provide a 100Base-FX fiber port and delivers low cost, fiber optic connectivity to the desktop in fiber-rich LAN environments.

With standard- and low-profile form factors, these NICs have driver support for most popular operating systems, and PCI 2.2 / 2.1 plug-and-play capabilities. These fast Ethernet NICs can be installed in virtually any PC on the network. The N-FX-xx-03 modules include both Standard and Low Profile brackets.

Contents

Introduction ... 1

Contents... 1

Models / Part Numbers ... 1

Installation ... 2

Description ... 2

Installation Procedure ... 2

Configuration... 3

PCI Bus System and Configuration ... 3

Wake-on-LAN (WoL)... 3 LED Functions... 4 Cable Specifications... 4 Technical Specifications... 5 Drivers Supported... 5 Troubleshooting ... 6 Diagnostics LEDs ... 6 Contact Us... 6 Compliance Information ... 7 Declaration of Conformity ... 7 FCC Regulations ... 7 Canadian regulations... 8 European regulations... 8 Record of Revisions ... 8

Models / Part Numbers

The available part numbers are described below.

Part Number Duplex Fiber-Optic Port

N-FX-ST-03 ST, 1310 nm multimode, 2 km (1.2 miles)* N-FX-SC-03 SC, 1310 nm multimode, 2 km (1.2 miles)* N-FX-LC-03 LC, 1310 nm multimode, 2 km (1.2 miles)*

(2)

Installation

Description

The N-FX module has bootable ROM and Wake-On LAN capabilities. The two LED indicators, LINK/ACT and FDX, located on the bracket, show network/board link, activities, collision, and full-duplex statuses. See Figure 1 below.

Figure 1: LEDs and Wake-On LAN Connector

Installation Procedure

CAUTION: Wear a grounding strap and observe electrostatic discharge precautions when installing the N-FX module. Failure to observe this caution could result in damage or failure of the N-FX module. Perform the steps below to install the N-FX NIC. Important: Install the N-FX module in a “master slot” only.

1. Select one of the two options for WoL to match the host PC’s capabilities: a. via WoL 3-pin connector (Fig. 1 above), or

b. via PCI bus; see Wake-on-LAN (WoL)on page3.

2. Locate a master slot on the PC workstation or file server.

3. Remove the cover from the PC workstation or file server - keep all screws. 4. Remove and keep the screws holding the cover to the installation slot. 5. Carefully align the module to the slot guides and slide it into the “master slot.” 6. Ensure that the module is firmly seated in the slot.

7. Use the screws saved in Step 4 above to secure the module to the workstation or file server housing.

(3)

Configuration

For motherboards with automatic PCI configuration:

 No specific setup is needed. (You can enter the system BIOS setup menu to view or specify the interrupt (INT) line of the PCI slots.)

For motherboards with bus master and interrupt jumpers:

 Enable bus master operation in a selected PCI slot and select an INT request line (IRQ) level, using the appropriate motherboard jumper.

 Enable I/O on the N-FX, PCI slot.

PCI Bus System and Configuration

 Ensure that the PCI machine supports master slots, INT multiple sharing, and timing compatibility.

 DO NOT install N-FX in PCI slave slots. Please refer to your PC system manual and select the appropriate configuration settings.

 When installing multiple N-FX modules in a server station, you can correctly configure the IRQ settings of the PCI slot.

 Up to four N-FX modules can be installed in a PCI file server, running a NetWare operating system.

 N-FX server modules share the same INT line with the driver supporting multiple INT services at a time. The IRQ of each N-FX module should not conflict with other boards.

 Operation in full duplex (default) or half-duplex mode is configured by LAN driver options. The operating mode should match the working status of the remote link device.

 Use EMM386 version 4.49 or higher, and install both DOS and EMM386 from the same DOS package to avoid software problems.

Wake-on-LAN (WoL)

This section outlines the methods for configuring WOL based on the type of PCI bus in the PC.

Wake-on-LAN is implemented using a special network message called a magic packet. The magic packet contains the MAC address of the destination computer. The listening computer waits for a magic packet addressed to it and then initiates system wake-up. The magic packet is sent on the data link (OSI layer 2) and is broadcast to all NICs using the network broadcast address (the IP-address is not used).

TheTechnical Specificationssection of this manual shows: Wake-ON-LAN supports magic packets only:

 PCI 2.1 implemented via the 3-PIN WOL connector (WOL cable needed)  PCI 2.2 implemented directly via PME# signal (no WOL cable needed)

Note that PCI 2.2 does not use the WOL cable; the WOL function is done via the PCI slot.

For PCI 2.1, these slots do require the use of a WOL cable, and you are installing the N-FX-xx-03 in a PCI 2.1 slot and you want to use the WOL feature, use the provided WOL cable The WOL cable TN part number is 4100 (included with the N-FX-xx-03).

Most versions of Microsoft Windows integrate WoL functionality into the Device Manager, available in the Power Management tab of each network device. Often, the correct BIOS configuration is also required for WoL to function. In Windows Vista and higher, you can determine how the OS was powered up by running the powercfg / lastwake command in a CMD prompt to list the "Wake Source". The WoL event

(4)

LED Functions

The LED is a single green color.

LED Description

FDX ON Full duplex.

OFF Half duplex. Link/ACT ON Link OFF No link Blinking Activity

Cable Specifications

Fiber cable

Bit error rate: <10-9

Single mode fiber (recommended): 9 μm Multimode fiber (recommended): 62.5/125 μm

Multimode fiber (optional): 100/140, 85/140, 50/125 μm N-FX-ST-03 and N-FX-SC-03: 1310 nm multimode

Fiber optic transmitter power: min: -19.0 dBm max: -14.0 dBm Fiber optic receiver sensitivity: min: -30.0 dBm max: -140 dBm

Link budget: 11.0 dB

N-FX-LC-03: 1310 nm multimode

Fiber optic transmitter power: min: -19.0 dBm max: -12.0 dBm Fiber optic receiver sensitivity: min: -30.0 dBm max: -8.0 dBm

Link budget: 11.0 dB

(5)

Technical Specifications

Transition Networks’ Model N-FX-xx-03 supports 802.1P/Q VLAN tagging. Expansion bus standard: PCI 2.1, PCI 2.2 compliant

Data rate: 100Mbps fiber media

LEDs (on the bracket): • LINK/ACT • FDX (full/half duplex) Wake-On LAN: Supports magic packets only:

 PCI 2.1 implemented via the 3-Pin WOL connector  PCI 2.2 implemented directly via PME# signal (no

Wake-On LAN cable needed)

OS Support: Windows XP x32, Vista x32-64, Win7 x32-64, Win8 x32-64 Boot server support: PXE (default)

PCB dimensions: 2.2”W x 4.8”D x 0.9”H (55.9 mm x 121.9 mm x 23 mm) Shipping Weight: 1 lb (455 g) approximately

Power consumption: 2.5 Watts

MTBF: greater than 550,000 MIL-HDBK-217G hours

greater than 1,520,000 Bellcore hours

Operating temp: 0°C to 50°C (32°F to 122°F) Storage temp: 40°C to 85°C (-40°C to 185°F)

Humidity: 5% to 90%, non-condensing

Warranty: Lifetime

WARNING: Visible and invisible laser radiation when open: DO NOT stare into the beam or view directly with optical instruments. Failure to observe this warning could result in damage to your vision or

blindness.

CAUTION: Use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

The information in this manual is subject to change without further notice.

Drivers Supported

The set of drivers supported includes:

 Windows Server 2008 / Windows Server 2008 R2 NIC Drivers,  Windows 2000 Server / Windows Server 2003,

 Windows 2000 / Windows XP, Windows XP 64-bit,  Windows Vista, Windows 7, Windows 8, and  Solaris 10 Drivers.

(6)

Troubleshooting

Diagnostics LEDs

LEDS

The LINK/ACT LED lights when a fiber cable connection is good. It blinks to indicate activity. The collision and full-duplex LED report PC board operating status.

After power UP, the LINK/ACT LED should light; if not, check the following: 1. Confirm that the N-FX module is properly inserted into the master slot.

2. Confirm that the PC is properly connected to a power source and that the power source is turned ON.

3. Check the fiber cable for proper connection.

4. Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600 if those steps fail to produce the desired result.

Contact Us

Technical support

Technical support is available 24-hours a day US and Canada: 1-800-260-1312

International: 00-1-952-941-7600 Transition now

Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link. Web-based seminars

Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link. E-Mail

Ask a question anytime by sending an e-mail to our technical support staff at

[email protected] Address

Transition Networks 10900 Red Circle Drive

Minnetonka, MN 55343, U.S.A. telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322 My TN Access

Simplify your TN experience; register at http://www.transition.com/TransitionNetworks/MyTNAccess/

and become a MY TN Access registered user. You will get a more personalized experience for registering products; Software/Firmware/Driver updates; Have access to all of our training tools, videos, content and downloads; Technical documentation and information about support assistance; and Receive email alerts of new products according to personal interest.

(7)

Compliance Information

Declaration of Conformity

FCC Regulations

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a

particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 Reorient or relocate the receiving antenna

 Increase the separation between the equipment and receiver

 Connect the equipment into an outlet on a circuit different from that of the receiver  Consult the dealer or an experienced radio/TV technician for help

(8)

Canadian regulations

This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

European regulations

Caution: This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse B. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich.

Attention! Ceci est un produit de Classe B. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.

In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper

disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.

Record of Revisions

Rev Date Notes

A 3/25/11 Initial release revision.

B 11/28/12 Add WoL information (PCI v 2.1 vs. 2.2) and 8-1/2x11” format.

All trademarks and registered trademarks are the property of their respective owners. Trademark notice

All registered trademarks and trademarks are the property of their respective owners. Copyright restrictions

© 2011, 2012 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means—graphic, electronic or mechanical—without written permission from

References

Related documents

This result is in good agreement with other measurements elsewhere of the strontium ion clock transition frequency [29], and when both statistical and systematic errors are

specialty meats, specialty cheeses, fermentation products (foods as well as breweries/distilleries), multi- ingredient convenience productsB. • Not to replicate what’s

Using DHCP enables the receiver to automatically obtain the IP address, Netmask, Broadcast, Gateway, and DNS address from the network.. When a receiver is connected to a network

Ten years into the reign of Thorin the First, son of Thráin the Old, the King resolved to remove the royal house of Durin’s folk from Erebor to abide in the Grey Mountains.. At the

Step 1: Draw the configuration diagram.. • Problem 11: For the mechanism shown in figure link 2 rotates at constant angular velocity of 1 rad/sec construct the velocity polygon

Major Goolsby’s Pub &amp; Grill Miller Time Pub &amp; Grill Milwaukee Brat House Milwaukee Brewing Company Milwaukee Chophouse Mo’s a Place for Steaks Mo’s Irish Pub Milwaukee

If the FHSS radio also filters, then it must relay IP packets sent to the IP broadcast address and to the IP ‘this’ address (IP address with network field set to 0). A device

– if adapter receives frame with matching destination address, or with broadcast address (e.g. ARP packet), it passes data in frame to network layer protocol. – otherwise,