Power Cable Accessories
Catalogue & Price List
Foreword
The U.K Electricity industry has changed beyond recognition over
the last 20 years with the privatisation of the distribution sector,
the consolidation of the old regional electricity companies, the
emergence of independent network operator licenses and the
proliferation of renewable energy projects as the country drives to
create more green power.
The power cable accessories product portfolio has also changed with
the emergence of cold applied products to facilitate quicker installations,
separable connectors which enable the easy connection and disconnection
of cables from switchgear and more universally sized components that
cover a wider range of cables.
Jointing Technologies has prospered through this period of change to
become the U.K.’s leading power cable accessories distributor.
The company’s development has been achieved through its partnerships
with market leading manufacturers, an in depth understanding of the
power cables accessories market, a total commitment to stock and most
importantly by putting the customer first.
This focus on customers old and new remains integral to our business now
and in the future.
Adam Lloyd
Managing Director
Contents
Company Capability
2
Cable Glands
7
Cable Lugs & Connectors
27
Cable Cleats
47
Cable Ties & Marking Systems
63
LV Jointing
73
HV Jointing & Terminating
89
Separable Connectors
127
Tapes, Aerosols & Accessories
137
Cable Laying Products
149
Earthing, Lightning & Surge Protection
157
Cable Transits
175
Tools & Equipment
183
Trace & Underfloor Heating Systems
197
Cable Data
205
Product Index
217
www.jointingtech.co.uk
2
Company Capability
SCOPE OF ACTIVITY
Cable Accessories account for the least
capital expenditure in the electricity
distribution network when compared
with switchgear, transformers and
cable. They can however, prove to be
the weakest part of it; as they require
assembly on site. Therefore the correct
product selection, technical advice and
installation of power cable accessories
are essential to ensure the safe running
of the U.K. electricity network.
Jointing Technologies are a specialist power
cable accessories distributor with a national
coverage operating in the electricity and
associated markets at voltages up to and
including 132KV.
We work in partnership with market
leading manufacturers to service the core
electricity segments like the Distribution
Network Operators (DNOs), Independent
Network Service Operators (IDNOs), Power
Contractors, Cable Pullers and HV Jointers to
ensure that the right products are selected
and best technical advice is offered relative
to each application.
We are also in a unique position based on
our knowledge and insight at higher voltages
to supply LV products to the general electrical
market.
The product portfolio consists of Cable
Glands, Cable Lugs & Connectors, Cable
Cleats, Cable Ties & Marking Systems,
LV Jointing, HV Joints & Terminations,
Separable Connectors, Tapes, Aerosols &
Accessories, Cable Laying Products, Earthing,
Lightning & Surge Protection, Cable Transits,
Tooling & Equipment & Trace & Underfloor
Heating Systems.
Jointing Technologies operates
nationally across a 3 branch
network ...
We hold in excess of £3 million of stock nationwide
to ensure we negate the long lead times from
manufacturers and fulfil customer demand quickly.
The Jointing Technologies fleet of 6 vans is utilised
to ensure we offer same and next day deliveries
nationwide and provide a unrivalled service to our
customers.
We employ 5 Sales Engineers who are tasked with the
development and support of our expanding customer
base in addition to providing the right technical advice
to aid with product selection.
Please contact your nearest sales office for details of
your local Sales Engineer.
Jointing Technologies operates a 24 hour call out service
to ensure materials are available in an emergency
to support our customers who work late or over the
weekend.
Company Capability
MARKET KNOWLEDGE
Jointing Technologies’ knowledge of the U.K. electricity
network puts us in a unique position to advise on the
most suitable products and technologies based on each
LV & HV application to ensure all customers find the
safest and most reliable solutions.
The electricity network and the cables installed have changed significantly over the last 50 years;
which has created challenges for power contractors when jointing or terminating cables.
Therefore an in depth knowledge of cable construction is essential in identifying the correct cable accessory product.
Jointing Technologies has the technical knowledge and expertise to advise the power contracting market on
product selection and find a solution when OLD cables (Paper or Lead sheathed etc) are found buried and
manufacturers don’t have an off the shelf product available
We have over 35 years’ experience working with the electricity market to provide power contracting solutions
and offer product training, in conjunction with our market leading manufacturers, to our customer base.
We have a unique understanding of the product profiles
used by each customer segment and work closely
with the market leading manufactures to advise what
products have been approved for use on each respective
DNO network.
The U.K electricity distribution network is divided up
by distribution network operator (DNO) and region as
shown on the map below.
Power Distribution
www.jointingtech.co.uk
4
Company Capability
CASE STUDIES
Greater Gabbard Wind Farm
Greater Gabbard is one of the world’s largest offshore
wind farm with a 500MW capacity consisting of an
onshore facility linked by three 45km cables to an
offshore substation. This is supplied by 140 turbines
located 23km off the Suffolk coast and the facility is
expected to provide power to around 530,000 homes.
SSE & RWE NPower Renewables are developing this project with
Balfour Beatty who have been commissioned to undertake all the
electrical installation work for the project covering voltages up to
132kV.
Jointing Technologies have worked with Balfour Beatty design and
installation teams to ensure that the right power cable accessories
products were specified and supplied for the application in
addition to providing on site training where necessary on the
installation of these materials. Jointing Technologies scope of
supply included Pfisterer Connex terminations, a comprehensive
range of MV joints and terminations from Tyco Electronics and
single and trefoil cleats from Prysmian.
Jointing Technologies at the time of print have supplied over £1M
of materials into Greater Gabbard project and have demonstrated
our ability to work on one of the largest and most prestigious
projects in the world.
The Shard
Shard London Bridge is a skyscraper constructed
in south London which is the tallest building in
the European Union. The tower will stand 1,017ft
(310m) tall with 72 floors, plus 15 further
radiator floors in the roof. The building has been
designed with an irregular triangular shape from
the base to the top. It will be clad entirely in
glass and have an open-air observation deck on
the top floor. The building will consist of Office
space, a Spa, Residential Apartments and a
Shangri-La Hotel.
Jointing Technologies worked in conjunction with the main
contractor to ensure the right products were selected for
the application and supplied many products on this project
including MV terminations from Tyco Electronics, Separable
Connectors for 22kV cables from ABB in addition to a range
of cast iron cleats for FP cables from Prysmian and cable
support systems from Band-IT.
This is one of the many prestigious projects in the U.K
currently supplied by Jointing Technologies.
Company Capability
CUSTOMER TESTIMONIALS
For many years now Jointing Technologies has proven to be reliable throughout our many projects. Their excellent
customer service, product knowledge and their wide range of competitively priced products make Jointing Technologies
a company that we will rely on time and time again.
Mike Watts
Buyer
“ Jointing Technologies has been a principal supplier of jointing accessories and components to SSE Contracting for
many years; their reliable performance assists us in providing our clients with the service they expect from a leading
UK mechanical & electrical contractor.”
Richard Hunt
HV Manager
“ We have used Jointing Technologies for many years and have found they offer a very professional service in the
supply of power cable accessories. Their products are of high quality, from market leading brands. Their flexible
approach and attention to detail has been greatly appreciated over the years.”
David Loftus
Buyer - Power Division
Jointing Technologies offer a range of power cable accessories nationally from market leading brands which is stocked
in depth and supported technically to ensure that our medium and high voltage contracts are completed on time and
within budget. This is why Jointing Technologies have become the supplier of choice for power cable accessories to
Murphy Ltd for more than 10 years with materials used extensively across the U.K electricity network on contracts
including EDF & CE Electric.
Martin Goodger
www.jointingtech.co.uk
6
Company Capability
MANUFACTURER’S BRANDS
Tyco Electronics, with an annual turnover of $12 billion, is
a global provider of engineered components for thousands
of consumer and industrial products; network solutions
and systems for telecommunications and energy markets,
undersea telecommunication systems, and speciality
products. The Tyco Electronics Energy division is the
leading manufacturer of power cable accessories that
includes the internationally recognised Raychem brand,
connectors and fittings, insulators and surge protectors,
insulation enhancement and many more. Tyco Electronics
has been at the forefront of the energy industry for the last
50 years and through continual innovation and product
development is still the brand of choice today.
3M is a large multi national with a turnover of over
$24 billion worldwide. They supply a wide variety of
products for use in the home, in the health care sector and
in industry. 3M has a strong reputation for quality and
innovation and currently supplies products in almost every
country in the world. The 3M Electrical Markets division
boasts a broad portfolio of LV & MV products consisting of
joints, terminations, tapes & accessories and are the market
leader for coldshrink technology products worldwide.
A worldwide leader in the energy and telecommunication
cables industry with a strong position in high technology
market segments, a global presence across 39 countries
with 56 plants and 12,000 employees. Prysmian was
formed by the Pirelli Group following its acquisition
of BICC in 2000 and continues to invest and develop
the market leading portfolio of BICON branded cable
accessories which consists of Cable Glands, Cable Cleats,
Cable Lugs in addition to LV/MV Joints and Accessories.
Thomas & Betts is a global leader with over 100 years
experience successfully supplying quality products by
using innovative design and manufacturing techniques.
With leading brands such as Furse, Emergi-Lite, Ty-Rap,
Adaptaflex, Kopex and PMA. The Thomas & Betts product
solutions portfolio includes earthing and lightning
protection, emergency lighting and fire detection, cable
management, electrical products and flexible conduit
systems.
ABB is a Global Leader in Power and Automation
technologies with 117,000 employees in over 100
Countries. ABB’s business unit for Power Cable Accessories
is located in Alingsås, Sweden and was started in 1888
by a Swedish cable manufacturer. The portfolio consists
of a range of Kabeldon branded Joints, terminations,
connectors, tools and accessories for power cables for
voltages up to and including 420 kV.
Cembre is one of the largest European manufacturers of
electrical compression connectors and related installation
tooling. Extensive know-how in the field , strong R&D
activity and continuous innovation in manufacturing
technologies and product specification, matched with
expert and efficient international sales teams and sharp
focus on customer needs, guarantee high-quality products
that are reliable, durable and safe. Cembre Ltd is a key
manufacturing unit within the Cembre group, with offices,
laboratory and plant located near Birmingham, while an
active sales force is available to customers throughout the
UK and Ireland.
Pfisterer are world renowned specialists for the design
and manufacture of contact elements and distribution
systems in low-, medium- and high-voltage networks. Our
range of cable accessories, components and overhead line
products offer solutions for virtually all applications in the
area of medium-voltage and high-voltage engineering
currently up to 300 kV for cable systems. Pfisterer have
a comprehensive portfolio of products for virtually all
terminating and jointing applications as well as worldwide
training/installation and advisory services.
Roxtec was founded in Sweden in 1990. Today it is the
world’s leading manufacturer of innovative cable and pipe
transit systems, supplying many of the globe’s biggest
firms. It has a global turnover of 96m Euros and is active
in 70 countries working in a diverse range sectors which
include Marine, Oil and Gas, Telecoms, Construction, Power
Generation, Transmission and Distribution.
Cable Glands
CONTENTS
Product Selection Data Tables
8
Stuffing Glands
9
Industrial Glands
11
Integral Earth Glands
16
Hazardous Area Glands
18
www.jointingtech.co.uk
8
Cable Glands
PRODUCT SELECTOR
CABLE GLAND & CLEAT SELECTOR
CABLE GLAND & CLEAT SELECTOR
FOR XLPE/SWA/PVC AND LSF 600/1000 VOLT POWER CABLES
CABLE SPEC GLANDS CLEATS Conductor
area mm2 Number of cores BW Indoor CW Outdoor E1WFE1W Telcleats 385AA Hook Cleats 371AA Claw Cleats Aluminium
370BA Plastic LSF Cleats E Aluminium Cleats SW1/2B
1.5
2 20S 20SS 20SS 1 - 1 0 -3 20S 20SS 20SS 1 - 1 0 -4 20S 20S 20S 1 - 1 0 -7 20S 20S 20S 2 - 2 1 2 12 20 20 20 3 - 3 2 3 19 25 25 25 4 - 4 3 4 27 25 25 25 5 - 5 4 5 37 32 32 32 6 5 6 5 6 48 32 32 32 6 5 6 5 62.5
2 20S 20S 20S 1 - 2 0 2 3 20S 20S 20S 1 - 2 1 2 4 20S 20S 20S 2 - 2 1 2 7 20 20 20 2 - 3 2 3 12 25 25 25 4 - 4 3 4 19 25 25 25 5 - 5 4 5 27 32 32 32 6 5 6 5 6 37 40 40 40 6 5 6 6 64
23 20S20 20S20 20S20 22 -- 22 11 22 4 20 20 20 3 - 3 2 36
23 2020 2020 2020 33 -- 33 22 33 4 20 20 20 4 - 4 3 410
23 2525 2525 2525 44 -- 44 33 44 4 25 25 25 4 - 5 4 516
23 2525 2525 2525 44 -- 54 43 45 4 25 25 25 5 5 6 4 625
23 2532 2532 3225 45 5- 64 54 46 4 32 32 32 5 5 6 5 635
23 3232 3232 3232 55 5- 65 55 56 4 32 32 32 6 5 6 5 650
23 3232 3232 3232 56 55 66 55 66 4 40 40 40 6 5 6 6 670
23 3240 3240 4032 66 56 76 65 67 4 40 40 40 7 6 7 7 795
23 4040 4040 4040 67 66 77 76 77 4 50 50 50S 8 7 8 7 8120
23 4050 4050 50S40 77 67 87 76 78 4 50 50 50 8 8 9 8 9150
23 5050 5050 50S50S 78 78 98 87 89 4 50 50 50 - 9 10 9 10185
23 5050 5050 50S50 88 89 99 98 99 4 63 63 63S - 9 10 10 10240
23 5063 5063 63S50 8- 89 109 108 109 4 63 63 63 - 10 11 11 11300
23 6363 6363 63S63 -- 109 1110 119 1011 4 75 75 75S - 11 12 12 12400
23 6375 6375 75S63 -- 1011 1211 1210 1112 4 75 75 75 - 12 13 14 13www.jointingtech.co.uk
9
Cable Glands
PRODUCT SELECTOR/STUFFING GLANDS
SINGLE CORE ARMOURED CABLE RECOMMENDATIONS
XLPE/AWA/PVC – 600/1000 VOLT COPPER CONDUCTORS
SINGLE CORE ARMOURED CABLE RECOMMENDATIONS
XLPE/AWA/PVC – 600/1000 VOLT COPPER CONDUCTORS
SINGLE CORE UNARMOURED CABLE RECOMMENDATIONS
XLPE/PVC – 600/1000 VOLT COPPER CONDUCTORS
SINGLE CORE UNARMOURED CABLE RECOMMENDATIONS
XLPE/PVC – 600/1000 VOLT COPPER CONDUCTORS
Product Copper Conductor Size mm
2
50 70 95 120 150 185 240 300 400 500 630 800 1000
Aluminium Gland Size
GACW 25 25 25 25 32 32 40 40 50S 50 50 63 63
Brass Stuffing Gland Size
A1/A2 32 32 40 40 40 40 50S 50 50 63S 63S 75S 75
Product Copper Conductor Size mm
2
50 70 95 120 150 185 240 300 400 500 630 800 1000
Brass Stuffing Gland Size
A1/A2 25 25 25 32 32 32 40 40 50S 50 50 63S 63
nylon STUFFInG GlAnDS
nylon STUFFInG GlAnDS
Indoor/outdoor for unarmoured cables
FEATURES
●
● Designed to provide sealing and retention for use with unarmoured cables
●
● Suitable for indoor & outdoor use
●
● Manufactured from Polyamide PA6.6
●
● Sealing ring manufactured from Neoprene 50 sh A
●
● Available in black as standard and light grey and dark grey on request
●
● All prices are per single gland
TECHNICAL DATA ● ■ Temperature range -20°C to + 90°C ● ■ Flammability rating UL 94 - V2 ● ■ IP68 rated
Size P Fixing Hole Diametermm Diameter A Min-Maxmm B Spannermm mmC L Min-Maxmm
16 M16 x 1.5 16.5 5-10 19 8 22-27 20 M20 x 1.5 20.5 7-13 25 9 24-30 25 M25 x 1.5 25.5 10-17 30 10 28-39 32 M32 x 1.5 32.5 13-21 36 10 33-44 40 M40 x 1.5 40.5 19-28 46 10 36-45 50 M50 x 1.5 50.5 27-35 55 12 43-52 63 M63 x 1.5 63.5 34-45 66 12 45-55 Part
number Size Diameter Range Price Each £
A2 NyLON 16 16 5-10mm
2.05
A2 NyLON 20 20 7-13mm2.42
A2 NyLON 25 25 10-17mm3.26
A2 NyLON 32 32 13-21mm5.99
A2 NyLON 40 40 19-28mm16.91
A2 NyLON 50 50 27-35mm25.41
A2 NyLON 63 63 34-45mm31.24
Discount on application GLAND DETAILS P B Ø A C LPAGE 9 - NOT DRAWN AT 100% (THIS IS 70%) PAGE 11 PAGE 13 PAGE 14 PAGE 16 PAGE 18 PAGE 17 PAGE 19 PAGE 12 PAGE 10 A B C D E F PAGE 15 PAGE 20
PAGE 22 - NOT DRAWN AT 100% (THIS IS 60%)
PAGE 22 - NOT DRAWN AT 100% (THIS IS 60%)
PAGE 22 - NOT DRAWN AT 100% (THIS IS 60%)
PAGE 21 A B C D A B D E F B A F
www.jointingtech.co.uk
10
A2 - BRASS GLANDS
A2 - BRASS GLANDS
TECHNICAL DATA ● ■ EN 50262 ● ■ BS 6121:Pt 1:1989 ●■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature -20°C to +90°C
●
■ CuZn39Pb3 extruded brass alloy
used for guaranteed strength and performance
Indoor/outdoor for unarmoured cables
FEATURES
●
● Brass indoor and outdoor cable gland and accessories
●
● For circular, unarmoured plastic or rubber sheathed cables
●
● Suitable for most climatic conditions, weatherproof and waterproof
●
● Kit comprises: A1/A2 gland, brass locknut and shroud
●
● Available in LSF version
●
● All prices are per single gland kit
●
● Please refer to product selection table on page 8 to size product relative to cable type
Size
Cable Dimensions mm Overall Diameter A
Gland Dimensions mm Entry Thread Approx.
Length from Shoulder D
mm
Hexagon Size Min Max Size
B Length C Across Flats E Across Corners F
20SS 3.5 8.5 M20×1.5 10 20 22.0 24.9 20S 8.0 11.5 M20×1.5 10 22 22.0 24.9 20 11.0 13.5 M20×1.5 10 22 24.0 26.8 25 13.0 19.5 M25×1.5 10 25 30.5 34.0 32 19.0 25.5 M32×1.5 10 25 42.4 48.0 40 25.0 32.0 M40×1.5 15 33 47.2 53.6 50S 31.5 37.0 M50×1.5 15 30 55.0 60.0 50 36.5 43.0 M50×1.5 15 30 56.4 61.5 63S 42.5 50.0 M63×1.5 15 34 70.1 77.2 63 49.5 55.0 M63×1.5 15 32 75.0 83.0 75S 54.5 61.0 M75×1.5 15 32 80.0 87.4 75 60.5 67.0 M75×1.5 15 40 85.0 95.0 GLAND DETAILS
Cable Glands
STUFFING GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
* 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
A1/A2 Brass Gland Kit KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
Part number
Size Price Each £ Standard LSF Standard LSF A1/A2 20SS A1/A2 20SS LSF 20SS
4.70
5.35
A1/A2 20S A1/A2 20S LSF 20S5.30
5.35
A1/A2 20 A1/A2 20 LSF 205.50
6.05
A1/A2 25 A1/A2 25 LSF 258.25
9.85
A1/A2 32 A1/A2 32 LSF 3213.75
14.85
A1/A2 40 A1/A2 40 LSF 4023.10
25.85
A1/A2 50S A1/A2 50S LSF 50S29.70
33.00
A1/A2 50 A1/A2 50 LSF 5031.35
38.50
A1/A2 63S A1/A2 63S LSF 63S48.40
57.20
A1/A2 63 A1/A2 63 LSF 6352.80
59.40
A1/A2 75S A1/A2 75S LSF 75S82.50
88.00
A1/A2 75 A1/A2 75 LSF 7588.00
97.90
Discount on application A B C D E Fwww.jointingtech.co.uk
11
Cable Glands
INDUSTRIAL GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK * 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
Indoor type for SWA cable
FEATURES
●
● Brass indoor gland and accessories
●
● For galvanized-steel single-wire armour plastic or rubber sheathed cables
●
● For use in dry, dust free, situations
●
● Provides mechanical cable retention and electrical continuity via armour locking mechanism
●
● Kit comprises: BW gland, brass earth tag, zinc plated steel locknut and shroud
●
● Available in LSF version
●
● All prices are per single gland kit
BW GLAND KIT - INDOOR USE
BW GLAND KIT - INDOOR USE
Size
Cable Dimensions mm Gland Dimensions mm Under Armour
Diameter A Max
Entry Thread Approx. Length from
Shoulder F mm
Hexagon Size Size
D Length E Across Flats G Across Corners H
20S 11.6 M20×1.5 10 24 22.0 24.9 20 13.9 M20×1.5 10 25 27.0 30.5 25 19.9 M25×1.5 10 26 37.6 42.2 32 26.2 M32×1.5 10 28 47.3 53.6 40 32.1 M40×1.5 15 25 50.0 57.0 50 44.0 M50×1.5 15 36 70.1 77.2 63 55.9 M63×1.5 15 30 80.0 87.4 75S 61.9 M75×1.5 15 40 85.0 95.0 75 67.9 M75×1.5 15 40 98.8 109.2 GLAND DETAILS TECHNICAL DATA ● ■ EN 50262 ● ■ BS 6121:Pt 1 :1989 ●
■ CuZn39Pb3 extruded brass alloy
used for guaranteed strength and performance
●
■ Service temperature range -20°C to
+90°C
●
● Please refer to product selection table on page 8 to size product relative to cable type A1/A2 Brass Gland Kit
KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
Part number
Size Price Each £ Standard LSF Standard LSF BW20S BW20S LSF 20S
2.90
4.00
BW20 BW20 LSF 203.45
4.95
BW25 BW25 LSF 255.40
7.65
BW32 BW32 LSF 328.60
10.95
BW40 BW40 LSF 4017.40
24.75
BW50 BW50 LSF 5031.20
35.75
BW63 BW63 LSF 6351.65
59.40
BW75S BW75S LSF 75S77.85
109.95
BW75 BW75 LSF 7577.85
109.95
Discount on application A F E D G Hwww.jointingtech.co.uk
12
Cable Glands
INDUSTRIAL GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
* 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
Indoor/outdoor type for SWA cable
FEATURES
●
● Brass indoor and outdoor cable gland & accessories
●
● For circular, galvanized-steel single-wire-armour plastic or rubber sheathed cables
●
● Outer seal grips sheath of cable
●
● For use in most climatic conditions, weatherproof and waterproof
●
● Three part amour lock with separate armour locking ring, ideal for checking electrical continuity
●
● Kit comprises: CW gland, brass earth tag, zinc plated steel locknut and shroud
●
● Available in LSF version
●
● All prices are per single gland kit
CW GLAND KIT - OUTDOOR USE
CW GLAND KIT - OUTDOOR USE
Size
Cable Dimensions mm Gland Dimensions mm Under Armour
Diameter Max
Overall
Diameter Armour Wire Diameter Entry Thread Length from Approx. Shoulder F
mm
Hexagon Size Min Max Size D Length E Across Flats G Across Corners H
20SS 8.6 8.0 13.2 0.9 M20×1.5 10 44 23.4 26.7 20S 11.6 8.0 15.8 0.9 M20×1.5 10 46 25.7 29.2 20 13.9 11.7 20.8 0.9/1.25 M20×1.5 10 46 30.5 34.0 25 19.9 17.0 27.2 1.25/1.6 M25×1.5 10 51 37.6 42.2 32 26.2 23.5 33.5 1.6/2.0 M32×1.5 10 56 47.3 53.6 40 32.1 29.0 39.9 1.6/2.0 M40×1.5 15 59 56.4 61.5 50S 38.1 38.0 46.2 2.0/2.5 M50×1.5 15 64 65.5 72.1 50 44.0 39.5 52.6 2.0/2.5 M50×1.5 15 64 70.1 77.2 63 55.9 51.3 65.3 2.5 M63×1.5 15 67 80.0 87.4 75 67.9 62.5 78.0 2.5 M75×1.5 15 76 98.8 109.2 85 74.0 68.0 88.0 3.15 M85×2 20 110 115.0 126.0 GLAND DETAILS
A1/A2 Brass Gland Kit KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk TECHNICAL DATA ● ■ EN 50262 ● ■ BS 6121:Pt 1:1989 ●
■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature range -20°C to
+90°C
●
■ CuZn39Pb3 extruded brass alloy
used for guaranteed strength and performance
●
● Please refer to product selection table on page 8 to size product relative to cable type
Part number
Size Price Each £ Standard LSF Standard LSF CW20SS CW20SS LSF 20SS
6.25
6.95
CW20S CW20S LSF 20S5.65
6.95
CW20 CW20 LSF 206.25
8.75
CW25 CW25 LSF 258.50
12.45
CW32 CW32 LSF 3216.30
18.50
CW40 CW40 LSF 4028.15
34.00
CW50S CW50S LSF 50S44.00
56.00
CW50 CW50 LSF 5044.00
56.00
CW63 CW63 LSF 6371.00
96.00
CW75 CW75 LSF 75118.00
142.00
CW85 CW85 LSF 85249.00
335.00
Discount on application F E D H Gwww.jointingtech.co.uk
13
Cable Glands
INDUSTRIAL GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK * 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
Indoor/outdoor type for aluminium wire armoured cable
FEATURES
●
● Aluminium indoor and outdoor cable gland & accessories
●
● For circular, aluminium single-wire-armour plastic or rubber sheathed cables
●
● Outer seal grips sheath of cable
●
● For use in most climatic conditions, weatherproof and waterproof
●
● Three part amour lock with separate armour locking ring, ideal for checking electrical continuity
●
● Kit comprises: CW aluminium gland, aluminium earth tag, aluminium locknut and shroud
●
● Available in LSF version
●
● All prices are per single gland kit
CW ALUMINIUM GLAND KIT
CW ALUMINIUM GLAND KIT
GLAND DETAILS TECHNICAL DATA ● ■ EN 50262 ● ■ BS 6121:Pt 1:1989 ●
■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature range -20°C to
+90°C
●
■ 6082 extruded aluminium alloy
used for guaranteed strength and performance
Size
Cable Dimensions mm Gland Dimensions mm Under Armour
Diameter Max
Overall
Diameter Armour Wire Diameter Entry Thread Length from Approx. Shoulder F
mm
Hexagon Size Min Max Size D Length E Across Flats G Across Corners H
20 13.9 11.7 20.8 0.9/1.25 M20×1.5 10 46 30.5 34.0 25 19.9 17.0 27.2 1.25/1.6 M25×1.5 10 51 37.6 42.2 32 26.2 23.5 33.5 1.6/2.0 M32×1.5 10 56 47.3 53.6 40 32.1 29.0 39.9 1.6/2.0 M40×1.5 15 59 56.4 61.5 50S 38.1 38.0 46.2 2.0/2.5 M50×1.5 15 64 65.5 72.1 50 44.0 39.5 52.6 2.0/2.5 M50×1.5 15 64 70.1 77.2 63 55.9 51.3 65.3 2.5 M63×1.5 15 67 80.0 87.4 75 67.9 62.5 78.0 2.5 M75×1.5 15 76 98.8 109.2 ●
● Please refer to product selection table on page 9 to size product relative to cable type A1/A2 Brass Gland Kit
KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
Part number
Size Price Each £ Standard LSF Standard LSF GACW20S GACW20SLSF 20S
20.48
21.00
GACW20 GACW20LSF 2020.48
24.15
GACW25 GACW25LSF 2520.48
25.20
GACW32 GACW32LSF 3225.20
33.60
GACW40 GACW40LSF 4032.03
39.90
GACW50S GACW50SLSF 50S45.15
57.75
GACW50 GACW50LSF 5045.68
60.90
GACW63 GACW63LSF 6371.93
88.20
GACW75 GACW75LSF 75147.00
168.00
Discount on application F E D H Gwww.jointingtech.co.uk
14
Cable Glands
INDUSTRIAL GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
* 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
CX GLAND - WIRE BRAIDED CABLE
CX GLAND - WIRE BRAIDED CABLE
Indoor/outdoor type for wire braided cable
FEATURES
●
● Brass indoor and outdoor cable gland & accessories
●
● For circular, wire braid armour plastic or rubber sheathed cables
●
● Outer seal grips sheath of cable
●
● For use in most climatic conditions, weatherproof and waterproof
●
● Three part amour lock with separate armour locking ring, ideal for checking electrical continuity
●
● Kit comprises: CX gland, brass earth tag, brass locknut and shroud
●
● All prices are per single gland kit
A1/A2 Brass Gland Kit KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk TECHNICAL DATA ● ■ EN 50262 ● ■ BS 6121:Pt 1:1989 ●
■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature range -20°C to
+90°C
●
■ CuZn39Pb3 extruded brass alloy
used for guaranteed strength and performance
GLAND DETAILS
Size
Cable Dimensions mm Gland Dimensions mm Under Armour
Diameter Max
Overall
Diameter Armour Wire Diameter Entry Thread Length from Approx. Shoulder F
mm
Hexagon Size Min Max Size D Length E Across Flats G Across Corners H
20SS 8.6 8.0 13.2 0.2/0.3 M20×1.5 10 44 23.4 26.7 20S 11.6 8.0 15.8 0.2/0.3 M20×1.5 10 46 25.7 29.2 20 13.9 11.7 20.8 0.2/0.3 M20×1.5 10 46 30.5 34.0 25 19.9 17.0 27.2 0.2/0.45 M25×1.5 10 51 37.6 42.2 32 26.2 23.5 33.5 0.3/0.45 M32×1.5 10 56 47.3 53.6 40 32.1 29.0 39.9 0.3/0.45 M40×1.5 15 59 56.4 61.5 50 44.0 39.5 52.6 0.3/0.45 M50×1.5 15 64 70.1 77.2 63 55.9 51.3 65.3 0.3/0.45 M63×1.5 15 67 80.0 87.4 75 67.9 62.5 78.0 0.3/0.45 M75×1.5 15 76 98.8 109.2 Part
number Size Price Each £
CX20SS 20SS
9.95
CX20S 20S9.95
CX20 2012.75
CX25 2518.00
CX32 3225.00
CX40 4047.00
CX50 5070.00
CX63 63120.00
CX75 75180.00
Discount on application F E D A H Gwww.jointingtech.co.uk
15
Cable Glands
INDUSTRIAL GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK * 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
E1W BRASS GLAND KIT
E1W BRASS GLAND KIT
Indoor/outdoor weatherproof for SWA cables
FEATURES
●
● Brass indoor and outdoor cable gland & accessories
●
● For circular plastic or rubber sheathed cables with extruded bedding
●
● Outer seal grips sheath of cable
●
● Inner seal grips bedding layer of cable
●
● For use in most climatic conditions, weatherproof and waterproof
●
● Three part armour lock with separate armour locking ring, ideal for checking electrical
continuity ●
● Kit comprises: E1W gland, brass earth tag, zinc plated steel locknut and shroud
●
● Available in LSF version
●
● All prices are per single gland kit
A1/A2 Brass Gland Kit KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk TECHNICAL DATA ● ■ EN 50262 ● ■ BS 6121:Pt 1:1989 ●
■ Inner and outer seal rated to IP66
●
■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature range -20°C to
+90°C
●
■ CuZn39Pb3 extruded brass alloy
used for guaranteed strength and performance
GLAND DETAILS
Size
Cable Dimensions mm Gland Dimensions mm Under Armour
Diameter Max
Overall
Diameter Armour Wire Diameter
Entry Thread Approx. Length from
Shoulder F mm
Hexagon Size
Min Max Min Max Size D Length E Across Flats G Across Corners H
20SS 6.3 8.6 8.0 13.2 0.9 M20×1.5 15 44 23.4 26.7 20S 8.7 11.6 8.0 15.8 0.9/1.25 M20×1.5 15 46 25.7 29.2 20 11.7 13.9 11.7 20.8 0.9/1.25 M20×1.5 15 46 30.5 34.0 25 13.0 19.9 17.0 27.2 1.25/1.6 M25×1.5 15 51 37.6 42.2 32 20.0 26.2 23.5 33.5 1.6/2.0 M32×1.5 15 56 47.3 53.6 40 26.3 32.1 29.0 39.9 1.6/2.0 M40×1.5 15 59 56.4 61.5 50S 32.2 38.1 38.0 46.2 2.0/2.5 M50×1.5 15 64 60.0 66.0 50 38.2 44.0 39.5 52.6 2.0/2.5 M50×1.5 15 64 70.1 77.2 63S 44.1 50.0 50.0 58.9 2.5 M63×1.5 15 67 75.0 83.0 63 50.1 55.9 51.3 65.3 2.5 M63×1.5 15 67 80.0 87.4 75S 56.0 61.9 62.0 71.6 2.5 M75×1.5 15 76 90.2 99.1 75 62.0 67.9 62.5 78.0 2.5 M75×1.5 15 76 98.8 109.2 ●
● Please refer to product selection table on page 8 to size product relative to cable type
Part number
Size Price Each £ Standard LSF Standard LSF E1W20SS E1WLSF20SS 20SS
10.50
17.50
E1W20S E1WLSF20S 20S10.50
16.95
E1W20 E1WLSF20 2012.60
21.00
E1W25 E1WLSF25 2518.90
29.00
E1W32 E1WLSF32 3226.00
39.00
E1W40 E1WLSF40 4047.60
71.30
E1W50S E1WLSF50S 50S67.00
104.00
E1W50 E1WLSF50 5069.00
117.00
E1W63S E1WLSF63S 63S117.00
158.00
E1W63 E1WLSF63 63119.00
175.00
E1W75S E1WLSF75S 75S148.80
237.00
E1W75 E1WLSF75 75197.00
280.00
Discount on application F E D H Gwww.jointingtech.co.uk
16
Cable Glands
INTEGRAL EARTH GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
* 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
CW BRASS GLAND WITH INTEGRAL EARTH
CW BRASS GLAND WITH INTEGRAL EARTH
TECHNICAL DATA
●
■ EN 50262
●
■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature range -20°C to
+90°C
●
■ Integral earth connection complies
with GDCD 190 Category A (43.3kA for 1 second)
For steel wire armour cable
FEATURES
●
● Brass indoor and outdoor cable gland with earth bonding connection
●
● Suitable for circular galvanised steel single wire armoured, plastic or rubber sheathed cables
●
● Outer seal grips sheath of cable
●
● For use in most climatic conditions, weatherproof and waterproof
●
● Three part armour lock with separate armour locking ring
●
● Kit comprises CW brass gland with integral earth & locknut
●
● All prices are per single gland kit
●
● For use in high fault current applications
A1/A2 Brass Gland Kit KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
GLAND DETAILS
Size
Cable Dimensions accommodated mm Gland Dimensions mm Under Armour
Diameter Max
Overall
Diameter Armour Wire Diameter Entry Thread Approx. Length from
Shoulder F mm
Hexagon Size
Min Max Min Max Size D Length E Across Flats G Across Corners H
20S - 11.6 8.0 15.8 0.9/1.25 M20×1.5 10 56 30.5 34.0 20 - 13.9 11.7 20.8 0.9/1.25 M20×1.5 10 56 30.5 34.0 25 - 19.9 17.0 27.2 1.25/1.6 M25×1.5 10 63 42.4 48.0 32 - 26.2 23.5 33.5 1.6/2.0 M32×1.5 10 73 56.4 61.5 40 - 32.1 29.0 39.9 1.6/2.0 M40×1.5 15 77 56.4 61.5 50 - 44.0 39.5 52.6 2.0/2.5 M50×1.5 15 84 70.1 77.2 63 - 55.9 51.3 65.3 2.5 M63×1.5 15 84 90.1 100.0 75 - 67.9 62.5 78.0 2.5 M75×1.5 15 94 106.2 117.0 85 - 74.0 68.0 88.0 3.15 M85×2 20 125 115.0 126.0 Part
number Size Price Each £
CWCIEL20S 20S
25.00
CWCIEL20 2034.00
CWCIEL25 2540.50
CWCIEL32 3258.50
CWCIEL40 4077.00
CWCIEL50 5095.00
CWCIEL63 63136.00
CWCIEL75 75205.00
CWCIEL85 85430.00
Discount on application F E D H Gwww.jointingtech.co.uk
17
Cable Glands
INTEGRAL EARTH GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK * 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
CW ALUMINIUM GLAND WITH INTEGRAL EARTH
CW ALUMINIUM GLAND WITH INTEGRAL EARTH
GLAND DETAILS
For aluminium wire armour cable
FEATURES
●
● Aluminium indoor and outdoor cable gland with earth bonding connection
●
● Suitable for circular aluminium single wire armoured, plastic or rubber sheathed cables
●
● Outer seal grips sheath of cable
●
● For use in most climatic conditions, weatherproof and waterproof
●
● Three part armour lock with separate armour locking ring
●
● Kit comprises CW aluminium gland with integral earth & locknut
●
● All prices are per single gland kit
●
● For use in high fault current applications
A1/A2 Brass Gland Kit KM409 Series
Industrial Gland Kits
>Brass indoor and outdoor cable gland & accessories >For circular, unarmoured plastic or rubber sheathed cables >Suitable for most climatic conditions, weatherproof and waterproof
>Kit comprises: - A1/A2 Gland
- Brass locknut
- PVC shroud >2 per kit size up to and including 25mm Features & Benefi ts
Ref: A1A2/03/07
Technical Data >EN 50262
>BS6121:Pt 1:1989
>Gland rated to IP66 with use of suitable sealing washer or thread sealant at gland interface
>Service temperature -20°C to +90°C
>CuZn39Pb3 extruded brass alloy used for guaranteed strength and performance
>Indoor/Outdoor for Unarmoured Cable Application
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9HP, UK
Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
TECHNICAL DATA
●
■ EN 50262
●
■ Gland rated to IP66 with use of
suitable sealing washer or thread sealant at gland interface
●
■ Service temperature range -20°C to
+90°C
●
■ Integral earth connection complies
with GDCD 190 Category A (43.3kA for 1 second)
Size
Cable Dimensions accommodated mm Gland Dimensions mm Under Armour
Diameter A Max
Overall
Diameter B Armour Wire Diameter
C Entry Thread Approx. Length from Shoulder F mm Hexagon Size
Min Max Min Max Size D Length E Across Flats G Across Corners H
32 - 26.2 23.5 33.5 1.6/2.0 M32×1.5 10 73 56.4 61.5 40 - 32.1 29.0 39.9 1.6/2.0 M40×1.5 15 77 56.4 63.2 50 - 44.0 39.5 52.6 2.0/2.5 M50×1.5 15 84 70.1 77.2 63 - 55.9 51.3 65.3 2.5 M63×1.5 15 84 90.2 99.1 75 - 67.9 62.5 78.0 2.5 M75×1.5 15 94 106.2 117.0 Part
number Size Price Each £
GACWCIEL32 32
62.00
GACWCIEL40 4084.00
GACWCIEL50 5094.00
GACWCIEL63 63123.00
GACWCIEL75 75183.00
Discount on application F E D A C H Gwww.jointingtech.co.uk
18
Cable Glands
HAZARDOUS AREA GLANDS
Gland Details
Ref: BARRX/04/07 B A D E F C m m s n o i s n e m i D d n a l G m m s n o i s n e m i D e l b a C s e z i S d a e r h T & s e c n e r e f e R d n a l G BasicSize Metric NPT Dia. Over Max. Conductors
Max. No. of
Conductors Inner Sheath Dia. ‘A’ OverallDia. ‘B’ BraidWire Dia. ‘C’ Approx. Length ‘D’ Hexagon Size Design
No. ThreadSize * DesignNo. Thread Size
≠ A/C
‘E’ A/F‘F’ Min Max Min Max
20S 424TX52 M20 × 1.5 424TX02 ½” - 14 NPT 11.0 30 — 11.5 8.0 15.8 0.2 / 0.3 67 34.0 30.5 20 424TX53 M20 × 1.5 424TX03 ½” - 14 NPT 11.0 30 — 12.5 11.7 20.8 0.2 / 0.3 64 34.0 30.5 25 424TX55 M25 × 1.5 424TX05 ¾” - 14 NPT 16.0 42 11.5 18.0 17.0 27.2 0.2 / 0.45 65 42.2 37.6 32 424TX56 M32 × 1.5 424TX06 1” - 11½ NPT 22.1 60 17.0 25.0 19.0 33.5 0.3 / 0.45 77 53.6 47.3 40 424TX57 M40 × 1.5 424TX07 1¼” - 11½ NPT 28.2 100 24.0 31.5 26.5 39.9 0.3 / 0.45 77 61.5 56.4 50 424TX59 M50 × 1.5 424TX09 2” - 11½ NPT 37.1 200 30.0 41.5 36.0 52.6 0.3 / 0.45 84 77.2 70.1 63 424TX61 M63 × 1.5 424TX11 2½” - 8 NPT 48.4 400 40.0 54.0 46.5 65.3 0.3 / 0.45 90 87.4 80.0 75 424TX63 M75 × 1.5 424TX13 3” - 8 NPT 58.6 400 53.0 65.5 58.0 78.0 0.3 / 0.45 96 109.2 98.8 85 424TX64 M85 × 2 424TX14 3” - 8 NPT 65.8 400 60.0 74.0 68.0 88.0 0.3 / 0.45 108 126.0 115.0
BARR-X EEx d IIC Brass Barrier Gland
Prysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK Commercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 5465
www.prysmian.co.uk
* 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
≠ NPT thread lengths comply with new UL2225 requirements
A2EX EEXD IP68 GLAND
A2EX EEXD IP68 GLAND
TECHNICAL DATA
●
■ Certified II 2GD, EEx e II & EEx d II
under ATEX directive 94/9/EC
●
■ Service temperature range –50°C to
+200°C
●
■ May be used in:
- Zones 0, 1 & 2 with EEx ia IIA, B & C equipment
- Zones 1 & 2 with EEx ib IIA, B & C equipment
- Zones 1 & 2 with EEx e II equipment
- Zones 1 & 2 with EEx p II equipment
- Zone 2 with EEx nA II equipment - Zones 21 & 22 with EEx tD II equipment
Part
number Size Price Each £
A1/A2EX 20SS 20SS
13.17
A1/A2EX 20S 20S14.00
A1/A2EX 20 2014.67
A1/A2EX 25 257.94
A1/A2EX 32 3220.76
A1/A2EX 40 4039.46
A1/A2EX 50 5054.52
A1/A2EX 63 6391.31
A1/A2EX 75S 75S121.07
A1/A2EX 75 75130.39
GLAND DETAILS BasicSize Thread Size*
Cable Dia. A mm Gland Dimensions mm Approx. length from shoulder B Hexagon Size Min Max Across Corners C Across Flats D
20SS M20×1.5 3.5 8.5 36 24.9 22.0 20S M20×1.5 8.0 11.5 36 24.9 22.0 20 M20×1.5 8.0 16.0 34 28.7 25.7 25 M25×1.5 11.5 21.0 44 36.9 33.0 32 M32×1.5 18.5 27.5 38 42.2 37.5 40 M40×1.5 24.0 34.0 46 53.6 47.2 50 M50×1.5 31.0 41.0 44 61.5 56.4 63 M63×1.5 40.0 52.5 61 77.2 70.0 75S M75×1.5 52.5 58.0 46 87.4 80.0 75 M75×1.5 54.5 65.5 66 87.4 80.0
* 1.5mm Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long
For unarmoured and braided cable
FEATURES
●
● Brass indoor and outdoor cable gland for use in hazardous areas
●
● Suitable for circular unarmoured cables with extruded oversheath
●
● Fitted with silicone rubber low smoke, zero halogen seal
●
● Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure
with suitable sealing washer or thread sealant ●
● Suitable for most climatic conditions – weatherproof, waterproof and deluge proof
●
● Dual seal option (A2EXP) avail