CODE MATRIX

CITY OF CHICAGO DEPARTMENT OF CONSTRUCTION & PERMITS

PART 1 - ZONING REQUIREMENTS

PART 2 - BUILDING REQUIREMENTS

PART 3 - EXITING REQUIREMENTS

ITEM ISSUE

CHAPTER/

ARTICLE

ORDNANCE

RQMNT

ACTUAL

RQMNT

N/A

SHEET

NO.

AGENCY/

TEST NO.

REMARKS

1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 2.01 2.02 2.03 2.04 OCCUPANCY CLASSIFICATION ZONING DISTRICT LOT AREA

MAX. FLOOR AREA RATIO TOTAL BUILDING AREA BUILDING HEIGHT MINIMUM SIDE YARDS

GRADE ELEVATION (CCD) OFF STREET LOADING OFF STREET PARKING MINIMUM FRONT YARD MINIMUM REAR YARD

ACCESSIBLE PARKING LANDSCAPING

TOWNHOUSE ORDINANCE

HEIGHT & AREA LIMITATIONS A) EXCEPTION TO AREA LIMITS B) MIXED OCCUPANCY BLDGS

2.05

TYPES OF CONSTRUCTION MIXED OCCUPANCY SEPARATIONS REQ. HRS. OF FIRE RESISTANCE EXTERIOR BEARING WALLS EXTERIOR NON-BEARING WALLS INTERIOR BEARING WALLS EXTERIOR COLUMNS INTERIOR COLUMNS - OTHER BEAMS - SUPPORTING ROOF ONLY BEAMS - OTHER FLOOR CONSTRUCTION ROOF CONSTRUCTION ELEVATOR FRAMING MEZZANINE FLOORS BASEMENT CONSTRUCTION DRIVEWAYS & LOADING SPACES FIRE RESISTIVE REQUIREMENTS A) FIRE WALL CONSTRUCTION B) PARAPETS

C) STAIRWAY ENCLOSURES D) ELEVATOR ENCLOSURES E) ENCLOSURE OF HEATING ROOMS F) ENCLOSURES OF WELLS & CHUTES G) OTHER ENCLOSURES

I) INT. WALL & CLING FINISHES FIRE RESISTIVE MATS & CONST ACCEPTED ENGINEERING PRACTICE RECOGNIZED AGENCIES

FIRE PROTECTION EQUIPMENT A) SPRINKLER SYSTEMS B) SPECIAL REQUIREMENTS 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 TYPES OF EXITS 3.01

MINIMUM NUMBER OF EXITS 3.02

TRAVEL DISTANCE TO EXISTS 3.03

A) INCREASE PERMITTED B) DEAD END CORRIDOR CAPACITY OF EXISTS 3.04

SWING OF EXITS DOORS HARDWARE REVOLVING DOORS LANDINGS HANDRAILS CONSTRUCTION ENCLOSURES HEADROOM CZO TITLE 17-R5 3 (13-56) p.115 5 (13-48) p.323 5 (13-48-090) p.325 5 (13-48-100) p.326 6 (13-60) p.329 3 (13-56-280) p.118 6 (13-60-100) p.331 TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) TABLE 6 (13-60-100) 6 (13-60-100) p.331 6 (13-60-160) p.332 6 (13-60-170) p.332 6 (13-60-210) p.332 7 (15-8) p.335 7 (15-8-010) p.335 7 (15-8-100) p.335 7 (15-8-140) p.337 7 (15-8-150) p.337 7 (15-8-190) p.338 7 (15-8-170) p.338 7 (15-8-240) p.339 7 (15-8-380) p.341 7 (15-12) p.327 7 (15-12-505) 9 (15-16) p.333 9 (15-16-010) p.334 9 (15-16-030) p.334 10(13-160-040)p.388 10(13-160-050)p.388 10(13-160-110)p.389 10(13-160-150)p.390 10(13-160-160)p.390 10(13-160-210)p.390 10(13-160-220)p.391 10(13-160-250)p.391 10(13-160-270)p.393 10(13-160-310)p.394 10(13-160-320)p.394 10(13-160-330)p.394 7 (15-8-140) p.337 10(13-160-350)p.394 PD810 3,440 sf EXIST'G Residential 12/150'-0" IB 3 hr. 3 hr. 3 hr. 3 hr. 3 hr. 2 hr. 2 hr. 2 hr. 2 hr. 2 Max. 100 Ft. 36 Inches Dir. of Egress K.D.E. N/A 36 Inches 2 hr. Non-Combust. Min. 7'-0" NO CHANGE Residential IB (2) Stairways 2 Provided 36 & 48 Inches NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE N/A EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G Dir. of Egress 36 & 48 Inches Provided Provided Provided Provided Provided N/A N/A Direction of Egress

Keyless in Direction of Egress

Provide Both Sides N/A

N/A

EXTERIOR NON-BEARING WALLS TABLE 6 (13-60-100) 2 hr.

Outside Exposure Inside Exposure

INTERIOR NON-BEARING WALLS TABLE 6 (13-60-100) 1/2 hr.

INTERIOR COLUMNS - SPPT'G ROOF ONLYTABLE 6 (13-60-100) 2 hr.

N/A N/A N/A N/A N/A N/A N/A N/A N/A 12/150'-0" 3 hr. 3 hr. 3 hr. 3 hr. 3 hr. 2 hr. 2 hr. 2 hr. 2 hr. 2 hr. 1/2 hr. 2 hr. N/A 2 hr. 2 hr. N/A N/A N/A Class 1 Class 1 Non-Combst. Non-Combst.

EXISTING 14-STORY

CONCRETE BLDG, N.I.C.

EXISTING 3-STORY

MASONRY BLDG, N.I.C.

TWO-WAY STREET

EXST'G PUBLIC ALLEY

EXST'G PUBLIC ALLEY

EXST'G PUBLIC ALLEY

PRIVATELY OWNED/ PRIVATELY FUNDED

EXISTING PARKING

0"

1' - 0"

0"

EXST'G LOADING/

PARKING ENTRANCE

EXST

'G

E

N

TRANCE

EXST

'G

E

N

TRANCE

0"

PROPOSED UNIT 701 INTERIOR REMODEL AND

NEW PRIVATE ROOF TERRACE

86' - 0"

1' - 0"

39' - 0"

THE FOLLOWING PROJECT IS THE

RENOVATION AND ADDITION OF A PRIVTE

ROOF TERRACE OF A PRIVATELY OWNED

CONDOMINIUM UNIT IN AN EXISTING

BUILDING. ALL WORK IS PRIVATELY

FUNDED AND THEREFORE NO

ACCESSIBILITY FEATURES ARE REQUIRED.

ANY ACCESSIBLITY FEATURES PROVIDED

ARE ON A VOLUNTARY BASIS.

Accessibility Note

Professional Stamp

I hereby certify that these plans and

specifications are prepared under my direct

supervision and to the best of my knowledge

conform to the City of Chicago Building Code

Lic. #001-012760

Drawing List

G1.0 PROJECT DATA, GENERAL NOTES,

SITE PLAN

D1.1 EXISTING/DEMO - 7th FLOOR PLAN

D2.1 EXISTING/DEMO - 7th FLOOR RCP

A1.1 UNIT 701 INTERIOR REMODEL

A1.2 UNIT 701 NEW PRIVATE ROOF TERACE

A2.1 OMITTED

A3.1 UNIT 701 INTERIOR REMODEL RCP

A4.1 ELEVATIONS

A5.1 BUILDING SECTION, SCHEDULES

A6.1 DETAILS

A7.1 ALUMINUM TRELLIS DETAILS

S1.0 4th THRU 7th FLOOR FRAMING PLANS

S1.1 MAIN ROOF FRAMING PLAN

S1.2 UPPER ROOF FRAMING PLAN

S2.0 FRAMING DETAILS

S2.1 FRAMING DETAILS

S3.0 GENERAL NOTES

P0.1 PLUMBING NOTES & RISER

P1.1 7TH FLOOR PLUMBING PLAN

P1.2 ROOF PLUMBING PLAN

E0.1 ELECTRICAL NOTES

E1.1 7TH FLOOR ELECTRICAL PLAN

E1.2 ROOF ELECTRICAL PLAN

EM1.2 ROOF EMERGENCY LIGHTING PLAN

General Notes

1. DRAWINGS GENERALLY INDICATE SCOPE OF WORK.

EACH CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS PRIOR TO START OF WORK TO ENSURE A

COMPLETE AND PROPER INSTALLATION OF THEIR

WORK.

2. ALL WORK SHALL COMPLY WITH ALL CITY, STATE,

AND FEDERAL ORDINANCES HAVING JURISDICTION.

NOTHING HEREIN SHALL BE INTERPRETED TO THE

CONTRARY. ALL PERMITS AND INSPECTIONS REQUIRED

SHALL BE SECURED BY THE CONTRACTOR INVOLVED.

3. PRIOR TO COMMENCING WORK, THE CONTRACTOR

SHALL PROVIDE A TIME SCHEDULE GRAPH INDICATING

START AND COMPLETION DATES FOR MAJOR WORK

ITEMS.

4. THE CONTRACTOR SHALL MAINTAIN ON THE JOB AT

ALL TIMES A COMPLETE SET OF DRAWINGS AND

SPECIFICATIONS, WHICH MUST BE KEPT MARKED UP TO

DATE.

5. THE CONTRACTOR SHALL MAINTAIN COMPETENT

AND THOROUGH SUPERVISION TO COORDINATE AND

ASSIST TRADES DURING THE PROJECT DURATION.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR

OBTAINING BUILDING PERMIT, AND ALL INSPECTIONS

AND APPROVALS.

7. THE SITE SHALL BE KEPT IN A SAFE, CLEAN AND

WORKMANLIKE CONDITION.

8. THE CONTRACTOR SHALL EXERCISE DUE CARE AND

PROVIDE ALL TEMPORARY PROTECTION FOR EXISTING

CONSTRUCTION FROM DAMAGE, AND REPAIR ANY

DAMAGE TO SUCH ITEMS AT HIS COST.

9. ALL WORK SHALL BE STRUCTURALLY SOUND AND OF

FIRST QUALITY WORKMANSHIP AND DETAIL.

10. ALL WORK SHALL CONFORM WITH ALL CITY, STATE,

FEDERAL REQUIREMENTS, CODES AND ORDINANCES

HAVING JURISDICTION. NOTHING HEREIN SHALL BE

INTERPRETED TO THE CONTRARY.

11. CONTRACTOR SHALL FILE WITH THE ARCHITECT

AND THE OWNER, PRIOR TO COMMENCEMENT OF THE

WORK, INSURANCE POLICIES WRITTEN BY COMPANIES

LICENSED IN THE STATE OF ILLINOIS AND MAINTAIN

UNINTERRUPTED UNTIL FINAL ACCEPTANCE OF THE

WORK:

WORKMAN'S COMPENSATION

EMPLOYER'S LIABILITY

COMPREHENSIVE BODILY INJURY

LIABILITY

PROPERTY DAMAGE LIABILITY AS REQUIRED BY

THE BUILDING DEPARTMENT

12. THE OWNER RESERVES THE RIGHT TO OCCUPY

PORTIONS OF THE PREMISES DURING PROGRESS OF

THE WORK AND PRIOR TO CONTRACT COMPLETION. HE

MAY ALSO ENGAGE SUPPLEMENTARY CONTRACTORS

OF HIS CHOICE DURING THIS TIME. THIS SHALL NOT,

HOWEVER, SIGNIFY COMPLETION OF THE WORK UNDER

THIS CONTRACT OR ACCEPTANCE.

13. AT THE CONCLUSION OF THE PROJECT, THE

CONTRACTOR SHALL CLEAN ALL NEW FIXTURES,

SURFACES, AND EQUIPMENT IN SUCH MANNER FOR

MOVE-IN.

14. SUBMIT "SHOP DRAWINGS" AND "SAMPLES" TO THE

ARCHITECT FOR REVIEW IN ACCORDANCE WITH THE

PROCEDURES OUTLINED IN THE GENERAL CONDITIONS

OF THE CONTRACT. SHOP DRAWINGS SUBMITTALS

SHALL INCLUDE DIMENSIONS, THICKNESS, PROFILES,

TYPE OF MATERIAL, METHOD OF FASTENING, RELATION

TO ADJACENT WORK AND OTHER NECESSARY DETAILS

TO FULLY DESCRIBE THE ITEM SUBMITTED. OTHER

SUBMITTAL REQUIREMENTS MAY INCLUDE BUT ARE NOT

LIMITED TO: FABRICATION, ERECTION, AND LAYOUT

DRAWINGS; MANUFACTURER'S STANDARD DRAWINGS,

SCHEDULES, DESCRIPTIVE LITERATURE, CATALOGS,

BROCHURES, PERFORMANCE TEST DATA, WIRING AND

CONTROL DIAGRAMS AND ALL OTHER DESCRIPTIVE

DATA PERTAINING TO EQUIPMENT, CONDUIT SYSTEMS

AND METHODS OF CONSTRUCTION.

15. ALL SHOP DRAWINGS AND CUTS ARE SIGNED

"REVIEWED" FOR ALL SUBMITTALS, UNLESS NOTED

OTHERWISE PER SPECIFICATIONS.

16. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.

LARGE SCALE DETAILS GOVERN OVER SMALLER SCALE

DETAILS.

17. ALL ELECTRICAL AND PLUMBING WORK TO BE

PERFORMED BY LICENSED CONTRACTORS.

18. THE ARCHITECT SHALL INTERPRET THE INTENT OF

THE DOCUMENTS IN CASES OF POSSIBLE CONFLICT OR

DISCREPANCY BETWEEN DISCIPLINES.

19. REFER TO LEGEND SHEET FOR PARTITION TYPES

AND DIMENSION INFORMATION.

20. ALL WORK SHALL BE GUARANTEED AGAINST

DEFECTS AND POOR WORKMANSHIP FOR A PERIOD OF

ONE YEAR FROM THE DATE OF SUBSTANTIAL

COMPLETION AS DETERMINED BY THE ARCHITECT.

21. THE CONTRACTOR SHALL MAKE NO SUBSTITUTIONS

OF MATERIALS AND/OR MANUFACTURERS AS LISTED IN

THE DRAWINGS, WITHOUT PRIOR WRITTEN APPROVAL

FROM THE ARCHITECT.

22. AT THE COMPLETION OF THE JOB, THE

CONTRACTOR SHALL PROVIDE ONE COMPLETE

MARKED-UP SET OF DRAWINGS WITH AS-BUILT

CONDITIONS.

23. CONTRACTOR TO PROVIDE AND MAINTAIN FIRE

EXTINGUISHERS ON CONSTRUCTION SITE DURING

WORK.

24. NO WORK SHALL COMMENCE WITHOUT BUILDING

APPROVAL AND SECURING OF REQUIRED PERMITS.

25. REFER TO SCHEDULES AND LEGENDS FOR

PRODUCT SPECIFICATIONS.

Scope of Work

INTERIOR REMODEL OF RESIDENTIAL UNIT

701 AND NEW PRIVATE ROOF TERRACE TO

INCLUDE TWO NEW STAIRS FROM THE 7th

FLOOR AS PER PLANS.

742 N. LaSalle

PROJECT TEAM

OWNER

ARCHITECT

STRUCTURAL ENGINEER

PRE-CAST CONCRETE ENGINEER M.E.P.

INTERIOR DESIGNER GENERAL CONTRACTOR

Finish Notes

1. All interior finishes to be class #1, 0-25 flame spread

rating.

2. Notify architect for clarification of any discrepancies

between written specifications and construction documents.

3. All wall surfaces to be painted gypsum board unless

noted otherwise.

4. All doors and trim for paint unless noted otherwise.

5. Stairs to be crafted according to plan and built by

contractor.

6. All floor coverings to be class "A" rated.

7. All interior finishes located within tenant spaces, shall be

verified and determined by the tenant.

8. All finished ceiling heights to be verified by contractor

prior to installation.

Fire Prevention Notes

1. All interior finishes to be class #1, 0-25 flame spread

rating, smoke developed 200.

2. All floor coverings to be class "A" rated

3. All glass doors and adjacent sidelights within 18" to be

tempered glass.

4. Fireplace to be pre-fab metal 42" w/ U.L. listed with

damper. Hearth as per city code. All fireplaces to have spark

arresters.

5. All bedrooms to have smoke detectors within 15' and

carbon monoxide detector within 40' (1 ea. per level minimum,

with battery backup.)

6. All exterior wood decking and support members to be

identified as subject to "standard rain test", unless otherwise

noted.

7. All exit doors to be keyless in the direction of egress.

8. Entry doors to have push/pull less than 8.5 lbs.

9. All floors to have smoke detectors and carbon monoxide

as indicated in CBC 13-64-120 and 13-63-190

10.Fireplaces to have non-combustible hearth per CBC

13-152-40, approved damper per CBC 13-152-480, and

clearance from combustibles per CBC 13-152-490-2.

11.All floor to floor penetrations including ducts, pipe shafts

shall be enclosed with construction providing not less than 1

hour.

12.All pipe, flue and vent penetrations to be firestopped by

using pipe covering and sealant as per UL# f-c-7007

Roof Notes

1. Continuously flash around all roof penetrations.

2. All roof drains to be located as per plumber's design.

Roofing contractor responsible all required pitches in roof for

proper drainage.

3. See structural drawings for all sizes and specification on

deck framing and support.

4. All exterior wood decking and support members to be

identified as subject to "standard rain test".

5. Roof coverings to be minimum Class 'B'.

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

G1.1

09/17/08

COVER SHEET

Sample Commercial Set

CHICAGO, ILLINOIS 60654

1/8" = 1'-0"

1

SITE PLAN

(2)

DN

DN

D

W

GF I GF I GF I GF I GF I GF I GF I GF I GF I GF I GFI

1

2

3

4

5

6

7

A

B

C

D

E

F

G

GAS

5.3

2.6

REMOVE KITCHEN ISLAND IN ITS ENTIRETY; MAINTAIN ELECTRIAL WIRING FOR USE IN NEW ISLAND

RANGE D ISH. REF. SINK WET BAR TO REMAIN

VERIFY WITH OWNER ALL MATERIALS, APPLIANCES AND CABINETRY TO BE SALVAGED AND/OR REUSED.

REMOVE EXIST'G STORE-FRONT SYSTEM; SAVE DOOR FOR REUSE REMOVE WALL

IN ITS ENTIRETY REMOVE WALL

IN ITS ENTIRETY

4'-6" 7'-5" 15'-2"

5'-8" 4'-6"

REMOVE DOOR, SAVE FOR REUSE, TYP. REMOVE DOOR, SAVE

FOR REUSE, TYP.

NOTE: VERIFY WITH OWNER ALL

MATERIALS, APPLIANCES AND CABINETRY TO BE SALVAGED AND/OR REUSED.

REMOVE BACKSPLASH, PREPARE WALL FOR NEW FINISHES

REMOVE WALL IN ITS ENTIRETY

REMOVE SOFFIT IN ITS ENTIRETY

REMOVE EXST'G STONE MANTEL AND SURROUND, PREPARE WALLS FOR NEW CONSTRUCTION MOVE EXIST'G WASHER/DRYER GREY

BOX/ PLUMBING PER NEW LOCATION

NOTE: VERIFY WITH OWNER ALL MATERIALS,

APPLIANCES AND CABINETRY TO BE SALVAGED AND/OR REUSED.

REMOVE EXISTING ROOF HATCH AND ACCESS LADDER

EXISTING ELEC. PANEL

REMOVE EXST'G CLOSET SYSTEM, PREPARE WALL FOR NEW CLOSET SYSTEM

LIVING

703

KITCHEN

705

BEDROOM

712

MASTER

BEDROOM

713

STUDY

714

STORAGE

716

MASTER BATH

715

BATH

711

EXST'G STAIR #2

S02

EXST'G STAIR #1

S01

HALL

706

BACK HALL

707

UTILITY

710

PWDR./ LAUNDRY

709

PWDR.

702

FOYER

701

DEMO EXST'G TILE ON WALLS AND FLOOR, REMOVE STONE SLAB @ BENCH AND SHOWER DOOR JAMB, PREP FOR NEW STONE DEMO EXST'G TILE FLOOR AND TUB

DECK, REMOVE EXISTING MIRROR

REMOVE EXIST'G COUNTER TOP

DEMO EXST'G TILE SURROUND

REMOVE EXST'G VANITY, PREPARE FOR NEW VANITY

DEMO EXST'G FLOOR, PREPARE FOR NEW TILE

6' -6 " 1 3 '-6 " REMOVE EXIST'G HARDWOOD FLOOR, PREPARE FOR TILE, SEE NEW CONST. FLR PLAN FOR

EXACT LOCATIONS

EXIST'G ELEVATOR

- NO WORK

(COMPLIES w/ ANSI 4.10

EXIST'G STORAGE

CLOSET

A.O.R. 30x48"

NOTE: 8" MAX. RISERS & 11" TREADS (10" +1" NOSING), TYP.

NOTE: 8" MAX. RISERS & 11" TREADS (10" +1" NOSING), TYP.

3 '-10" 8" 3 '-10" 3'-10" 6'-8" 8'-4" 3 /0x6/8 3 /0x6/8 8'-4" 6'-8" 3'-10" 3 '-10" 8" 3 '-10" 1'-0" 1'-11" 1'-11" 1'-11" 1'-11" 1'-0" REMOVE EXST'G HAND/GUARD RAIL TO

ALLOW FOR NEW STAIR LANDING

EXST'G FLOOR OUTLETS TO REMAIN EXISTING

LOW-VOLTAGE PANEL

EXST'G ALARM SYSTEM

CONTROL MOVE EXST'GTHERMOSTAT

CONTROL T EXST'G THERMOSTAT CONTROL TO REMAIN T EXST'G FURN. #1 EXST'G FURN. #2 E XST'G IN S T . H .W . EXST'G FD EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW T O REMAIN E1 E1 E1 E1 E1 E1 C1 C C C C C1 B D D D1 A A D1 D1 D F F F F E E F

713-1

712-1

714-1

7

15-2

711-1

702-1

715-1

716-1

S01-1

S02-1

712-2

713-2

709-1

710-1

REMOVE HARDWOOD FLR, PREPARE FOR TILE

UNIT 701

SD 110 VOLT HARDWIRED SD 110 VOLT HARDWIRED SD 110 VOLT HARDWIRED RELOCATE

REMOVE EXST'G

DOOR AND WALL

OMIT STAIR

FROM PERMIT

DRAWINGS

ADD STAIR TO

PERMIT

DRAWINGS

NEW CONSTRUCTION

DEMOLISHED WALL

EXISTING TO REMAIN

Wall Type Key

Demolition Notes

1. ALL WORK TO BE DONE IN ACCORDANCE WITH

APPLICABLE CODES THAT HAVE AUTHORITY OVER THIS

PROPERTY. PROVIDE ALL NECESSARY SAFEGUARDS,

BARRIERS, TEMPORARY POWER, FIRE PROTECTION

LIGHTING, ETC. AS REQUIRED DURING DEMOLITION.

2. DEMOLITION INCLUDES COMPLETE REMOVAL,

DISPOSAL OR SAVINGS OF SPECIFIED WORK.

3. SUBMIT PROPOSED METHODS AND OPERATION OF

DEMOLITION TO OWNER FOR REVIEW PRIOR TO START

OF WORK. INCLUDE IN SCHEDULE COORDINATION FOR

SHUTOFF, CAPPING AND CONTINUATION OF UTILITY

SERVICES AS REQUIRED.

4. ELECTRICAL, TELEPHONE, MECHANICAL & PLUMBING

SYSTEMS DELETED BY NEW CONSTRUCTION SHALL BE

REMOVED TO THE FURTHEST TERMINATION POINT U.O.N.

5. KEEP STAIRWAYS AND DOORWAY EXITS

UNOBSTRUCTED AND AVAILABLE FOR USE AT ALL TIMES

DURING DEMOLITION OPERATION.

6. ALL SALVAGEABLE SURPLUS BUILDING MATERIALS,

HARDWARE, WOOD TRIM, DOORS, LIGHT FIXTURES, ETC.

NOT INDICATED TO BE RELOCATED OR REUSED SHALL BE

TURNED OVER TO OWNER. COORDINATE STORAGE

LOCATION

7. SALVAGE, CLEAN, AND STACK STONE AND BRICK FROM

DEMOLITION OF GARAGE FOR REUSE IN CONSTRUCTION

OF FIRST FLOOR ADDITION.

8. GENERAL CONTRACTOR TO COORDINATE ALL TRADES

REQUIRED TO PERFORM DEMOLITION WORK AS

OUTLINED IN THESE CONTRACT DOCUMENTS.

9. PROVIDE TEMPORARY SHORING AS NECESSARY

10. DEMOLISH NON LOAD BEARING PARTITIONS ONLY

U.N.O.

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

D1.1

08/18/08

EXIST'G/ SELECT

DEMOLITION - 7th

FLR PLAN

1/4" = 1'-0"

1

UNIT 701 - EXISTING/ SELECT

DEMOLITION

1.1

3/10/09

1.1

3/10/09

#

Description

Date

1

STAR

ADD/REMOVAL

3/10/09

(3)

1

2

3

4

5

6

7

A

B

C

D

E

F

G

1

A5.1

4

A4.1

2

A4.1

5.3

2.6

1 1 1 1 1 1 1 6 6 6 6 6 6 6 1 6 6 6 2 2 1 1 1 4 4 4 5 5 5 6 5 5 6 6 6 6 6 6 6 5 5 5 5 5 5 5 5 5 5 SD SD SD

6

A6.1

5 5 5 5 5 5 5 5 5 5 2 2 7 7 2 2 W/LIGHT 3 1 1 HELLO W/LIGHT W/LIGHT 5 5 8 8

EXST'G RETURN AIR, MOVE PER NEW PLAN

EXST'G SUPPLY, TYP. EXST'G SPEAKERS, COOR. w/

LOW-VOLTAGE CONTRACTOR EXST'G EXPOSED CEILING

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

8'-7 1/4"

A.F.F.

GWB ON MTL. FURRING

7'-4 3/4"

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

8'-1"

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

8'-7"

A.F.F.

GWB ON MTL. FURRING

8'-3"

A.F.F.

GWB ON MTL. FURRING

8'-3"

A.F.F.

GWB ON MTL. FURRING

8'-3"

A.F.F.

GWB ON MTL. FURRING

8'-5"

EXST'G EXPOSED CEILING EXST'G EXPOSED CEILING LINE OF EXST'G SOFFIT LINE OF EXST'G PERIMETER SOFFIT LINE OF EXST'G PERIMETER SOFFIT

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

7'-10"

EXIST'G ELEVATOR

(COMPLIES w/ ANSI 4.10

4" 6" 6" 6" EXST'G LIGHTING TO BE REMOVED; SAVE FOR USE IN ANOTHER LOCATION, TYP. LINE OF CELING TO BE REMOVED FOR NEW STAIR, COORDINATE W/ NEW CONSTRUCTION PLAN, TYP.

EXST'G LIGHTING TO BE REMOVED; SAVE FOR USE IN ANOTHER LOCATION, TYP. SD 110 VOLT HARDWIRED SD 110 VOLT HARDWIRED RELOCATE

3" ADJUSTABLE HALOGEN SPOT

3" DOWN SPOT ADJUSTABLE HALOGEN

DINING ROOM LIGHT

PENDENT LIGHT

4" RECESSED CAN

CANDLE LIGHT

3" RECESSED WATER PROOFCAN

EXHUST FAN/ LIGHT COMBO

EMERGENCY LIGHT w/ BATTERY

BACKUP LIGHT

RCP LEGEND

1 2 3 4 5 6 7

Demolition Notes

1. ALL WORK TO BE DONE IN ACCORDANCE WITH

APPLICABLE CODES THAT HAVE AUTHORITY OVER THIS

PROPERTY. PROVIDE ALL NECESSARY SAFEGUARDS,

BARRIERS, TEMPORARY POWER, FIRE PROTECTION

LIGHTING, ETC. AS REQUIRED DURING DEMOLITION.

2. DEMOLITION INCLUDES COMPLETE REMOVAL,

DISPOSAL OR SAVINGS OF SPECIFIED WORK.

3. SUBMIT PROPOSED METHODS AND OPERATION OF

DEMOLITION TO OWNER FOR REVIEW PRIOR TO START

OF WORK. INCLUDE IN SCHEDULE COORDINATION FOR

SHUTOFF, CAPPING AND CONTINUATION OF UTILITY

SERVICES AS REQUIRED.

4. ELECTRICAL, TELEPHONE, MECHANICAL & PLUMBING

SYSTEMS DELETED BY NEW CONSTRUCTION SHALL BE

REMOVED TO THE FURTHEST TERMINATION POINT U.O.N.

5. KEEP STAIRWAYS AND DOORWAY EXITS

UNOBSTRUCTED AND AVAILABLE FOR USE AT ALL TIMES

DURING DEMOLITION OPERATION.

6. ALL SALVAGEABLE SURPLUS BUILDING MATERIALS,

HARDWARE, WOOD TRIM, DOORS, LIGHT FIXTURES, ETC.

NOT INDICATED TO BE RELOCATED OR REUSED SHALL BE

TURNED OVER TO OWNER. COORDINATE STORAGE

LOCATION

7. SALVAGE, CLEAN, AND STACK STONE AND BRICK FROM

DEMOLITION OF GARAGE FOR REUSE IN CONSTRUCTION

OF FIRST FLOOR ADDITION.

8. GENERAL CONTRACTOR TO COORDINATE ALL TRADES

REQUIRED TO PERFORM DEMOLITION WORK AS

OUTLINED IN THESE CONTRACT DOCUMENTS.

9. PROVIDE TEMPORARY SHORING AS NECESSARY

10. DEMOLISH NON LOAD BEARING PARTITIONS ONLY

U.N.O.

NEW CONSTRUCTION

DEMOLISHED WALL

EXISTING TO REMAIN

Wall Type Key

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

D2.1

09/17/08

EXIST'G/ SELECT

DEMOLITION - 7th

FLR RCP

1/4" = 1'-0"

1

T/ 7th FLR - RCP - EXISTING

#

Description

Date

(4)

DN

DN

UP

D

UP

1

2

3

4

5

6

7

A

B

C

D

E

F

G

1

A5.1

5.3

2.6

GAS NEW BANQUETTE SEATING

NEW WINE STORAGE

TILE HARDWOOD TILE HARDWOOD NEW 36x72" TABLE WA TER FEATU RE FULL-LITE SLIDING DOORS ON TRACK

CLEAR GLASS ON 3'-0" PARTIAL HEIGHT WALL w/ GLASS DOOR

EXTEND EXIST'G SOFFIT

NEW SOFFIT LINE, SEE REFLECTED CEILING PLAN NEW ENTRY CLOSET

NEW KITCHEN ISLAND

2'-11"

5'-8"

3'-1"

CENTER REUSED EXIST'G DOOR

6'-0"

2'-11"

4'-6"

3'-4"

5"

10'-0"

5"

4'-11"

3'-6"

1'-3" 1'-3" 2'-6"

5"

10'-0"

1'-3"

1'-3"

3'-8"

EXTEND EXIST'G WALLS TO UNDERSIDE OF SOFFIT, ALL WALLS TO RECEIVE 18x18" PORCELIN TILE

1'-9"

4'-2"

5"

2'-0"

5"

4'-4"

8"

1'-9"

9'-0"

11"

4'-6"

6'-10"

4'-6"

4'-2"

9'-0"

4'-4"

5'-0"

2'-0"

4"

1'-8"

2'-9"

5"

4'-5"

2'-5"

NEW STACKED WASHER/DRYER

STUDY

714

MASTER

BEDROOM

713

BEDROOM

712

KITCHEN

705

LIVING

703

DINING

N720

LOUNGE

N717

STORAGE

N719

WINE

N718

BANQUETTE

N723

STORAGE

716

MASTER BATH

715

BATH

711

BACK HALL

707

UTILITY

710

PWDR./ LAUNDRY

709

PWDR.

702

EXST'G STAIR #1

S01

EXST'G STAIR #2

S02

FOYER

701

W/

D

PROVIDE NEW SINGLE MIRROR a/ VANITES, COORDINATE w/ INTERIOR DESIGNER

PROVIDE NEW GRANITE SLAB @ BENCH; COORD. w/ INT. DESIGNER

PROVIDE NEW TILE FLR. @ ENTRY; COORD. w/ INT. DESIGNER PROVIDE NEW 12X12 TILE (PORCELAIN @ TUB SURROUND; COORD. w/ INT. DESIGNER

PROVIDE NEW WOOD FLOATING VANITY; COORD. w/ INT. DESIGNER

NEW 4x2 PORCILIN TILE BACKSPLASH

NEW CARPET BY OTHERS CARPET BY OTHERS CARPET BY OTHERS

CARPET BY OTHERS 12x24 TILE 12x24" TILE ON TUB DECK 12x24" TILE ON WALLS, TYP. HARDWOOD TILE 12x12 TILE GREEN BOARD AND INSULATION AT WINE CLOSET WALLS TILE

STAIN EXISTING BAMBOO FLOOR TO A DARKER SHADE;

COORD. W/ INT DESIGNER

NOTE: BANQUETTE BY INT. DESIGNER EX IS T IN G WET BAR 6 x 12 GLA SS TILE ON EAST WALL 12x24 TILE ON N,S,W, WALLS AND CEILING MOSAIC PENNY ROUND MESH 12x12 TILE FLOOR

NEW STONE VENEER WALL

NEW SOFFIT LINE, SEE REFLECTED CEILING PLAN

NEW NON-COMBUSTIBLE PRIVATE INTERIOR STAIR,

NOTE: UP 18R @8" MAX. RISERS & 11" TREADS (10" +1" NOSING), TYP.

EXIST'G ELEVATOR

- NO WORK

(COMPLIES w/ ANSI 4.10

A.O.R. 30x48" A.O.R. 30x48" NEW NON-COMBUSTIBLE STAIR

AND HAND/GUARD RAILINGS UP TO PRIVATE ROOF TERRACE, MATCH EXST'G CONTSTRUCTION; 8" MAX. RISERS & 11" TREADS (10" +1" NOSING), TYP.

NOTE: 8" MAX. RISERS & 11" TREADS (10" +1" NOSING), TYP. 1'-11" 3 '-10" 8'-4" 14'-8" 4'-6" EXST'G FD EXST'G NON-COMBUSTIBLE STAIR TO REMAIN,TYP.

NEW FLOOR-TO-CEILING MIRROR ON FULL NORTH WALL, REMAINING WALLS TO RECEIVE WALL COVERINGS; NEW SCONCES E.S. OF NEW MIRROR, NEW VANITY-COORD. w/ INT. DESIGNER, TYP.

NOTE: ALL EXST'G AND NEW INTERIOR PARTIONS WALLS TO BE 3 5/8" MTL STUD w (1) 5/8" GYP. BRD EACH SIDE, TYP

NOTE: ALL EXST'G PLUMBING FIXTURES NOT SPECIFICALLY CALLED-OUT TO REPLACED WILL BE RE-USED, TYP.

EXST'G RATED HOLLOW-CORE METAL DOOR w/ CLOSER TO REMAIN

EXST'G RATED HOLLOW-CORE METAL DOOR w/ CLOSER TO REMAIN E1 E1 E1 C1 C C C C E1 E1 E1 C1 B D D D1 F A A D1 EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW T O REMAIN EXISTING WINDOW TO REMAIN EX IS T IN G WINDOWS TO REMAIN E X ISTING WINDOWS T O REMAIN EXISTING WINDOW T O REMAIN D1 D F F F F F F E E F F

713-1

NEW PRIVATE

STAIR

N721

MEDIA CLOSET

N722

712-1

715-2

711-1

702-1

715-1

716-1

S01-1

S02-1

712-2

713-2

709-1

710-1

707-1

N722

EXST'G FURN. #1 EXST'G FURN. #2 E XST'G IN S T . H .W . 10"

UNIT 701

19'-5" 11'-7" 7'-10" 21'-6" 7'-4" 5'-1" 10'-9" 4" 83'-10" 5 '-11" 2' -9 " 10" 9' -2 " 9' -2 " 9' -6 " 37 '-4 " 4'-6" 6'-8" 3'-0" 1 1/2"

A6.2

1

4

A6.2

RRB-10/28/08

SD 110 VOLT HARDWIRED SD 110 VOLT HARDWIRED

Finishes Notes

1. Verify all tile layouts and patterns with Interior Designer 2. Verify color of floor stain with Interior Designer 3. Interior Designer to provide Bedroom Carpets 4. Interior Designer to provide Banquette 5. Painting by others

6. Curtains and fabrics by others

NEW CONSTRUCTION

DEMOLISHED WALL

EXISTING TO REMAIN

Wall Type Key

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A1.1

09/17/08

UNIT 701 - INTERIOR

REMODEL PLAN

1/4" = 1'-0"

1

UNIT 701 - NEW CONSTRUCTION

#

Description

Date

1

STAR

ADD/REMOVAL

(5)

NEW CONSTRUCTION

DEMOLISHED WALL

EXISTING TO REMAIN

Wall Type Key

EXIST'G AC UNITS TO

REMAIN, TYP.

EXST'G ROOF DRAIN AND OVERFLOW DRAIN TO REMAIN, TYP.

UNIT 701

EXST'G ROOF

EXST'G ROOF DRAIN AND OVERFLOW DRAIN TO REMAIN, TYP.

EXST'G SINGLE-PLY ROOF MEMBRANE OVER TAPPERED RIGID INSULATION

TO REMAIN, TYP. EXIST'G ELEV. OVERRUN TO REMAIN, NO WORK, TYP. EXST'G PARAPET TO REMAIN, TYP. EXST'G PARAPET TO REMAIN, TYP.

NEW STAIR TOWER, COORDINATE w/ NEW

CONSTRUCTION PLAN, TYP. NEW STAIR TOWER,

COORDINATE w/ NEW CONSTRUCTION PLAN, TYP.

49

'-4

"

44'-

5"

60'-9"

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A1.2

09/17/08

UNIT 701 - NEW

PRIVATE ROOF

TERRACE PLAN

1/8" = 1'-0"

2

UNIT 701 - EXISTING/ SELECT

DEMOLITION - ROOF PLAN

1/4" = 1'-0"

1

NEW PRIVATE ROOF TERRACE

1/8" = 1'-0"

3

EXITING DIAGRAM - NEW PRIVATE

ROOF TERRACE

REVISED 1-22-09

(6)

1

2

3

4

5

6

7

A

B

C

D

E

F

G

5.3

2.6

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

8'-1"

EXST'G TO REMAIN

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

8'-7"

A.F.F.

GWB ON MTL. FURRING

8'-3"

A.F.F.

GWB ON MTL. FURRING

8'-3"

A.F.F.

GWB ON MTL. FURRING

8'-5"

A.F.F.

GWB ON MTL. FURRING

7'-10"

EXST'G TO REMAIN

EXST'G TO REMAIN

EXST'G TO REMAIN

5'-8" 14'-4" 4"

1

'-10"

ALIGN NEW SOFFIT w/ FACE OF FIRE PLACE SURROUND NEW IN-FILL CEILING; MATCH

EXST'G FOYER CEILING HEIGHT

EXST'G TO REMAIN

EXST'G TO REMAIN

EXST'G TO REMAIN

EXST'G TO REMAIN

A.F.F.

GWB ON MTL. FURRING

7'-4 3/4"

LINE OF NEW SOFFIT LINE OF NEW SOFFIT LINE OF EXST'G SOFFIT EXST'G EXPOSED CEILING EXST'G EXPOSED CEILING

LINE OF NEW SOFFIT, B/ SOFFIT 8'-3" 6' -1 1 1/ 8 " 10'-2" OPEN TO ABOVE

EXST'G TO REMAIN

A.F.F.

GWB ON MTL. FURRING

7'-10"

A.F.F.

GWB ON MTL. FURRING

7'-10"

EXST'G TO REMAIN

EXST'G TO REMAIN

EXIST'G ELEVATOR

(COMPLIES w/ ANSI 4.10

NEW IN-FILL CEILING; MATCH EXST'G CLOSET CEILING HEIGHT

NEW CEILING; MATCH EXST'G KITCHEN/ DINING CEILING HEIGHT

A.F.F.

GWB ON MTL. FURRING

8'-1"

A.F.F.

GWB ON MTL. FURRING

8'-1"

EXST'G TO REMAIN

EXST'G TO REMAIN

1 1 1 6 6 6 6 6 2 2 1 1 1 4 4 4 5 5 5 6 6 6 6 6 6 5 5 5 5 5 5 5 5 5 5 SD SD SD 5 5 5 5 5 5 5 5 5 5 2 2 7 7 2 2 W/LIGHT 3 1 1 W/LIGHT W/LIGHT 5 5 8 8 RELOCATED EXST'G RETURN AIR EXST'G SUPPLY, TYP. EXST'G EXPOSED CEILING EXST'G EXPOSED CEILING LINE OF EXST'G PERIMETER SOFFIT LINE OF EXST'G PERIMETER SOFFIT

EXIST'G ELEVATOR

(COMPLIES w/ ANSI 4.10

LINE OF CELING TO BE REMOVED FOR NEW STAIR, COORDINATE W/ NEW CONSTRUCTION PLAN, TYP. NEW IN-FILL CEILING; MATCH

EXST'G FOYER CEILING HEIGHT

NEW TILE

CEILING,

COORD. w/

INTERIOR

DESIGNER

EXPOSED

OPEN TO ABOVE STAIR LANDING ABOVE

3" ADJUSTABLE HALOGEN SPOT

3" DOWN SPOT ADJUSTABLE HALOGEN

DINING ROOM LIGHT

PENDENT LIGHT

4" RECESSED CAN

CANDLE LIGHT

3" RECESSED WATER PROOFCAN

EXHUST FAN/ LIGHT COMBO

EMERGENCY LIGHT w/ BATTERY

BACKUP LIGHT

RCP LEGEND

1 2 3 4 5 6 7

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A3.1

09/19/08

UNIT 701 - INTERIOR

REMODEL RCP

1/4" = 1'-0"

1

UNIT 701 - INTERIOR REMODEL- NEW

RCP

(7)

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

A

B

C

D

1

A5.1

B/ STAIR TOWER

CEILINGS

86'-9 3/4"

T/ NEW STAIR

WALL PARAPET

89'-0"

T/ NEW STAIR

WALL PARAPET

89'-0"

NEW 48x48" OUTSIDE CURB DIMENSION PYRAMID SKYLIGHT BY "KALWALL"; COORDINATE CURB w/ SKYLIGHT MANUF. DTLS., TYP. NEW FIBER CEMENT PANELS EXISTING CONSTRUCTION - TYP

4

A6.2

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

1

2

3

4

5

6

7

B/ STAIR TOWER

CEILINGS

86'-9 3/4"

2

A4.1

5.3

2.6

T/ NEW STAIR

WALL PARAPET

89'-0"

EXISTING CONSTRUCTION - TYP

EXISTING CONSTRUCTION - TYP

EXISTING CONSTRUCTION - TYP LESS THE 4"

BETWEEN WALL AND RAIL

NEW STEEL GUARDRAIL SYSTEM, SEE DETAILS NEW FIBER CEMENT PANELS NEW FIBER CEMENT PANELS

NEW ALUMINUM TRELLIS SEE SHEET ON TRELLIS FOR DETAILS

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

A

B

CD

E

F

G

B/ STAIR TOWER

CEILINGS

86'-9 3/4"

T/ NEW STAIR

WALL PARAPET

89'-0"

NEW "GREEN SCREEN" PANEL SCREEN, TYP.

NEW FIBER CEMENT PANEL WALLS, TYP.

A6.1

6

Sim

EXISTING CONSTRUCTION, TYP

NEW ALUMINUM TRELLIS SEE SHEET ON TRELLIS

FOR DETAILS

NEW MOVEABLE, INSULATED FIBERGLASS PLANTERS, TYP. NEW BUILT IN BAR

-SEE DETAILS

A6.1

3

A6.1

6

Sim

A6.1

4

NEW PRECAST CONCRETE PAVERS ON LEVELERS 1' -0 " 1'-6 " PREFINISHED METAL COPING w/ DRIP EDGE, TYP.

3' -0 " 3' -0 "

NEW PRECAST CONCRETE PAVERS ON LEVELERS

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

1

2

3

4

5

6

7

B/ STAIR TOWER

CEILINGS

86'-9 3/4"

2

A4.1

5.3

2.6

T/ NEW STAIR

WALL PARAPET

89'-0"

A6.1

6

Sim

EXISTING CONSTRUCTION - TYP EXISTING CONSTRUCTION - TYP EXISTING CONSTRUCTION - TYP

NEW GREEN SCREEN PANEL

EXISTING AC UNITS

EXISTING ELEVATOR OVERRUN, NO WORK, TYP.

NEW GREEN SCREEN PANEL, TYP.

A6.1

6

Sim

NEW STEEL GUARDRAIL SYSTEM, SEE DETAILS

NEW FIBER CEMENT PANELS NEW ALUMINUM TRELLIS

SEE SHEET ON TRELLIS FOR DETAILS NEW 48x48" OUTSIDE CURB DIMENSION PYRAMID SKYLIGHT BY "KALWALL"; COORDINATE CURB w/ SKYLIGHT MANUF. DTLS., TYP. NEW FIBER CEMENT PANELS

R2-1

R1-1

A6.1

4

NEW 18x24x4" EXTENSIVE GREEN ROOF BY "GREEN GRID"

NEW PRECAST CONCRETE PAVERS ON LEVELERS, TYP. NEW PRECAST CONCRETE PAVERS ON LEVELERS LESS THEN 4" BETWEEN RAIL AND WALL (M IN . 42 ") 4' -0 " 2' -0 " 4' -0 " 10"

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A4.1

09/19/08

ELEVATIONS

1/4" = 1'-0"

1

ELVATION - STAIR TOWERS - EAST

1/4" = 1'-0"

3

ELEVATION STAIR TOWERS

-NORTH

1/4" = 1'-0"

2

ELEVATION/ SECTION - ROOF

TERRACE - WEST

1/4" = 1'-0"

4

ELEVATION/ SECTION - NEW

PRIVATE ROOF TERRACE - SOUTH

(8)

3 5/8" METAL STUD 16" O.C. & BATT INSULATION

(2) LAYER 5/8" GYPSUM BOARD EACH SIDE

(1) LAYER 1/2" DUROCK SHEATHING AS NEEDED @ TUB, LAV., & WATER CLOSET AREAS

3 5/8" METAL STUD 16" O.C. & BATT INSULATION 4" FACE MASONARY 2" AIR SPACE 8" 3HR. BLOCK - TYPE C3 4" FACE MASONARY 2" AIR SPACE 10" 3HR. BLOCK - TYPE C3 1 5/8" MI. METAL FURRING STRIPS & BATT INSULATION -SEE PLAN (1) LAYER 5/8" GYPSUM BOARD 10" CMU - TYPE C3 "HARVARD BRIK" PRODUCT

Wall Types

2 HR. FIRE RATED - NON LOAD BEARING INT. DEMISING WALL

NON LOAD BEARING INTERIOR PLUMBING WALL

3 HR RATED NON-LOAD BEARING EXTERIOR WALL

3 HR RATED NON-LOAD BEARING EXTERIOR WALL

C1

C

B

A

3 HR RATED LOAD BEARING INTERIOR WALL WITHOUT FURRING AND DRYWALL - BLOCK ONLY

D

D1

1 5/8" MI. METAL FURRING STRIPS & BATT INSULATION -SEE PLAN

(1) LAYER 5/8" GYPSUM BOARD

10" CMU - TYPE C3 "HARVARD BRIK" PRODUCT

E

E1

U.L. #U411

NO RATING

REQUIRED

U.L. #U904

RATING FROM BLOCK ONLY

U.L. #U904

RATING FROM BLOCK ONLY

U.L. #U904

RATING FROM BLOCK ONLY

U.L. #U904

RATING FROM BLOCK ONLY

U.L. #U904

RATING FROM BLOCK ONLY

U.L. #U904

RATING FROM BLOCK ONLY 3 HR RATED LOAD BEARING INTERIOR WALL WITHOUT

FURRING AND DRYWALL - BLOCK ONLY

3 HR RATED NON LOAD BEARING EXTERIOR WALL WITHOUT FURRING AND DRYWALL - BLOCK ONLY 3 HR RATED NON LOAD BEARING EXTERIOR WALL WITHOUT FURRING AND DRYWALL - BLOCK ONLY

3 5/8" METAL STUD 16" O.C. & BATT INSULATION

(1) LAYER 5/8" GYPSUM BOARD EACH SIDE

TYP. NON LOAD BEARING INTERIOR PARITION

F

NO RATING

REQUIRED

6" - 18 GA. CSJ MTL STUD 16" O.C. (SEE STRUCT. DWGS) w/ 5-1/2" R-19 BATT INSULATION

(2) LAYER 3/4" GYPSUM BOARD TYPE "IP-X3" OR "ULTRACODE" EACH SIDE

TYP. 3 HR EXTERIOR LOAD-BEARING STEEL STUD WALL

G

U.L. #U490

"WRAPSHIELD" WEATHER BARRIER MEMBRANE BY VAPROSHIELD, TAPE ALL SEAMS

1” - 18 GA. MTL FURRING CHANNEL @ 16" O.C. 5/16” HIGH DENSITY FIBER CEMENT PANEL VAPOR BARRIER (WARM SIDE)

IN TE R IO R

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

T/ 7th FLR CONC.

TOPPING

68'-4"

1

2

3

4

5

6

7

B/ STAIR TOWER

CEILINGS

86'-9 3/4"

2

A4.1

5.3

2.6

NEW COMMON STAIR LANDING, TYP.

80'-0"

80'-0"

T/ NEW STAIR

WALL PARAPET

89'-0"

- (1) 1/2" DIAMOND PLATE STEEL FLOOR - 1 1/2" MTL. DECK - 10" CFS MTL. JOIST - 5" COMPOSITE DECK, SEE STRUCT. DWGS EXST'G TYP. ROOF CONST.

(UL# J292 - MIN. 2hr.)

- (1) 2" PRECAST CONC. PAVERS ON LEVELERS - (1) GEOTEXTILE FILTER FABRIC

- (1) ROOF MEMBRANE

- MIN. 2" RIGID INSULATION, SLOPED TO DRAINS - EXIST'G 10" PRECAST HOLLOW-CORE PLANK w/ 2" LIGHT-WEIGHT CONCRETE TOPPING, SEE STRUCT. DWGS.

- FINISHED CEILING PER PLANS

PWDR.

702

PWDR./ LAUNDRY

709

UTILITY

710

EXST'G STAIR #1

S01

EXST'G STAIR #2

S02

EXIST'G ELEVATOR

(COMPLIES w/ ANSI 4.10

- SEE SCHEDULE

NEW EXTERIOR WALL, TYP. (UL# U490 - MIN. 3hr.) NEW STAIR TOWER ROOF

(MIN. 2hr RATED - UL# P723) - (1) SINGLE-PLY ROOF MEMBRANE - MIN. 2" RIGID INSULATION, SLOPE 1/4"/FOOT TOWARDS EAST WALL - (1) 1/4" RECOVERY BOARD - (1) 1 1/2" MTL. DECK, SEE STRUCT. - 10" CFS MTL. JOIST, SEE STRUCT. - (1) 1-5/8" MTL FURRING CHANNEL - (1) 5/8" GYP. BRD.

- SEE SCHEDULE

NEW EXTERIOR WALL, TYP. (UL# U490 - MIN. 3hr.)

NEW COMP. DECK LANDING AND STEEL FRAMING, SEE STRUCT

NEW NON-COMBUSTIBLE STAIR, GUARDRAIL AND HANDRAIL, TYP.

NEW 48x48" OUTSIDE CURB DIMENSION PYRAMID SKYLIGHT BY "KALWALL"; COORDINATE CURB w/ SKYLIGHT MANUF. DTLS., TYP. NEW STAIR TOWER ROOF

(MIN. 2hr RATED - UL# P723) - (1) SINGLE-PLY ROOF MEMBRANE - MIN. 2" RIGID INSULATION, SLOPE 1/4"/FOOT TOWARDS EAST WALL - (1) 1/4" RECOVERY BOARD - (1) 1 1/2" MTL. DECK, SEE STRUCT. - 10" CFS MTL. JOIST, SEE STRUCT. - (1) 1-5/8" MTL FURRING CHANNEL - (1) 5/8" GYP. BRD.

EXST'G PARAPET WALL BEYOND

EXST'G MECH. UNITS BEYOND

EXST'G CONC. PLAN TO REMAIN EXST'G CONC. PLANK TO REMAIN TO T H E B/ F IN ISH ED C E IL IN G 6' -9 3/ 4 " 18 '-5 3/ 4 "

NEW PRIVATE

STAIR

N721

- SEE SCHEDULE EXST'G WALL, TYP.(UL# U490 - MIN. 3hr.)

NEW PRIVATE STAIR LANDING - (1) 3/4" FINISH FLOOR - (2) 3/8" SUBFLOOR - 1 1/2" MTL. DECK - 8" CFS MTL. JOIST - 5" COMPOSITE DECK, SEE STRUCT. DWGS 8" 6' -9 3/ 4 "

NEW PRIVATE

STAIR

NR001

NEW EGRESS

STAIR

NR002

3 '-0 " , T YP. 3' -6 "

NEW 1-5/8" DIA. METAL PIPE HANDRAIL, VERT. RAILS MAX. 3.5" SPACING, TYP. - SEE SCHEDULE

NEW EXTERIOR WALL, TYP. (UL# U490 - MIN. 3hr.)

NOTE: ALL NEW STAIR SUPPORTING CONSTRUCTION (INCLUDING LANDINGS AND INTERMEDIATE CEILINGS) TO BE 2 hr. (15-8-130). STAIRS TO BE METAL CHECKER PLATE CONSTRUCTION w/ METAL PIPE HANDRAILS EACHSIDE.

EXST'G NON-COMBUSTIBLE STAIR, GUARDRAIL AND HANDRAIL, TYP.

A6.2

2

NEW COMP. DECK

LANDING AND STEEL FRAMING, SEE STRUCT

NEW DECORATIVE MTL. STAIR, SEE PLAN & DETAILS STONE VENEER

WALL BEYONE

3'

-6

"

NOTE: ALL SKYLIGHTS SHALL BE GLAZED WITH WIRED GLASS OR LAMINATED SAFETY GLASS HAVING NO SINGLE PANE EXCEEDING 720 SQUARE INCHES IN AREA

NOTE: ALL NEW RIGID INSULATION TO HAVE MAX. FLAME SPREAD RATING OF 25

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A5.1

09/22/08

BUILDING SECTION,

SCHEDULES

Mark Door Type Rough Height Rough Width Door Material Door Finish Frame Material Frame Finish Construction Type Hardware Comments

702-1 SWING 7'-0" 2'-8" WD PT WD PT NR 1 EXST'G TO

REMAIN

707-1 DBL SWING 7'-0" 6'-0" WD PT WD PT NR 4 RELOCTED DOOR

709-1 SWING 7'-0" 3'-0" MTL PT MTL PT NR 1 EXST'G TO REMAIN 710-1 SWING 7'-0" 3'-0" WD PT WD PT B 3 EXST'G TO REMAIN 711-1 SWING 7'-0" 2'-6" WD PT WD PT NR 1 EXST'G TO REMAIN 712-1 SWING 7'-0" 2'-8" WD PT WD PT NR 1 EXST'G TO REMAIN 712-2 DBL SWING 7'-0" 6'-0" WD PT WD PT NR 4 EXST'G TO REMAIN 713-1 SWING 7'-0" 2'-8" WD PT WD PT NR 1 EXST'G TO REMAIN 713-2 DBL SWING 7'-0" 6'-0" WD PT WD PT NR 4 EXST'G TO REMAIN 715-1 SWING 7'-0" 2'-6" WD PT WD PT NR 1 EXST'G TO REMAIN

715-2 SWING 7'-0" 2'-6" GLASS N/A MTL N/A NR 4 EXST'G TO

REMAIN

716-1 SWING 7'-0" 2'-6" WD PT WD PT NR 4 EXST'G TO

REMAIN

N722 SWING 7'-0" 2'-8" WD PT WD PT NR 4 NEW

R1-1 SWING 6'-8" 3'-0" ALUM PT MTL PT NR 2 NEW

R2-1 SWING 6'-10" 3'-0" ALUM PT MTL PT B 2 NEW

S01-1 SWING 7'-0" 3'-0" MTL PT MTL PT B 2 EXST'G TO

REMAIN

S02-1 SWING 7'-0" 3'-0" MTL PT MTL PT B 2 EXST'G TO

REMAIN

DOOR SCHEDULE & NOTES

DOOR

NOTES

1. Privacy

2. Keyed entry w/ panic hardware Surface mounted closer 3. Keyed entry

Surface mounted closer 4. Non locking door

HARDWARE

NOTES

HARDWARE

SCHEDULE

1. See plans for door mark, locations. and swing as shown 2. All doors are 7'-0" high unless otherwise noted. Verify all sizes in field

3. All new exterior doors to be anodized aluminum to match the color chosen by architect

4. Push/pull at entry doors no more then 85 pounds

1. Typical door manufacturer to be determined by contactor, lever handels in brushed chrome with brushed chrome square or round edged hinges (1-1/2) pair)

2. All exit doors are to be keyless in the direction of egress 3. All bathroom & bedroom doors to have privacy locks 4. Stairwell doors to have lever handle,panic hardware, and

ROOM FINISH SCHEDULE

1. All interior finishes to be class #1 0-25 flame spread rating 2. Notify architect for clarification of any discrepancies between

written specifications and construction documents 3. All doors and trim for paint unless noted otherwise 4. Atairs to be crafted according to plan and built by contactor 5. All floor coverings to be class "A" rated

6. All wall surfaces to be painted gypsum unless otherwise noted 7. Verify all tile patterns with Interior designer

8. Verify all colors of paints and stains with Interior Designer 9. Interior Designer to provide Banquette

10.Curtains and fabrics by others

Number Name Ceiling Finish Floor Finish

North Wall South Wall East Wall West Wall

Wall North

Material Wall North Finish

Wall South

Material Wall South Finish

Wall East

Material Wall East Finish

Wall West

Material Wall West Finish

701 FOYER PTD NEW 18x18 TILE GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

702 PWDR. PTD NEW 18x18 TILE GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

703 LIVING PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

705 KITCHEN PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

706 HALL PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

707 BACK HALL PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

709 PWDR./ LAUNDRY PTD NEW 18x18 TILE GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

710 UTILITY PTD EXISTING TO REMAIN GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

711 BATH PTD NEW 12x12 TILE GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

712 BEDROOM PTD NEW CARPET GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

713 MASTER BEDROOM PTD NEW CARPET GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

714 STUDY PTD NEW CARPET GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

715 MASTER BATH PTD NEW 12x24 TILE GYP BRD NEW 12 x24 TILE GYP BRD NEW 12x24 TILE GYP BRD NEW 12x24 TILE GYP BRD NEW 12x24 TILE

716 STORAGE PTD NEW CARPET GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N717 LOUNGE PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N718 WINE PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N719 STORAGE PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N720 DINING PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N721 NEW PRIVATE STAIR PTD N/A GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N722 MEDIA CLOSET PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

N723 BANQUETTE PTD NEW STAIN ON HARDWOOD GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

NR001 NEW PRIVATE STAIR PTD EXPOSED GYP BRD PTD GYP BRD PTD GYP BRD PTD GYP BRD PTD

NR002 NEW EGRESS STAIR N/A EXPOSED GYP BRD EXPOSED GYP BRD EXPOSED GYP BRD EXPOSED GYP BRD EXPOSED

S01 EXST'G STAIR #1 PTD EXISTING TO REMAIN BLOCK N/A BLOCK N/A BLOCK N/A BLOCK N/A

S02 EXST'G STAIR #2 PTD EXISTING TO REMAIN BLOCK N/A BLOCK N/A BLOCK N/A BLOCK N/A

ROOM FINISH NOTES

1/4" = 1'-0"

1

BLDG SECTION @ STAIR TOWERS

*

PROVIDE SAFETY GLASS ON FULL LITE

*

(9)

EXISTING HOLLOW-CORE CONCRETE PLANK w/ LIGHT-WEIGHT CONCRETE TOPPING ROOF STRUCTURE, TYP. REMOVE EXISTING INSULATION TO INSTALL POST BASEPLATE, FILL VOID WITH LOW EXPANSION FOAM INSULATION, REPLACE SINGLE-PLY ROOF MEMBRANE

FIELD-FABRICATED SINGLE-PLY MEMBRANE PIPE FLASHING, SEE DETAIL 3" TUBE STEEL w/ CLOSED TOP, SEE STRUCT. DWGS

STEEL POST BASEPLATE, SHIM/ GROUT AS REQ'G, SEE STRUCT. DWGS 1' -4 " 8" 8" 8" 8" 1'-4"

STEEL POST BASEPLATE, SHIM/ GROUT AS REQ'G, SEE STRUCT. DWGS

ADHESIVE ANCHORS, SEE STRUCT. DWGS.

ADHESIVE ANCHORS, SEE STRUCT. DWGS.

EXISTING TAPERED RIGID INSULATION

6 1/2" 6 1/2"

EXISTING SINGLE-PLY ROOF

MEMBRANE VARI

ES, SEE PLAN

6 1/ 2 " 6 1/ 2 " GREEN SCREEN PANEL

3" TUBE STEEL, SEE STRUCT. DWGS #5133 SNAP CLIP -HOOK CLIP ON BACK PANEL WIRE & ROTATE UNTIL IT "SNAPS" INTO POSITION

#5105 STEEL EDGE TRIM @ VERTICAL PANL EDGES, TYP.

#5105 STEEL EDGE TRIM @ VERTICAL PANL EDGES, TYP. GREEN SCREEN PANEL STAINLESS STEEL SELF-TAPPING TEK SCREW #5137 / #5139 POST CAP

A6.1

3

7"

1/4" STEEL PLATE FIELD WELD TO VERTICAL SUPPORT, SEE PLAN FOR LOCATIONS PRECAST CONC. PAVER ON LEVELER, SEE PLAN FOR SIZE AND HEIGHT

3" TUBE STEEL w/ CLOSED TOP, SEE STRUCT. DWGS

EXISTING HOLLOW-CORE CONCRETE PLANK w/ LIGHT-WEIGHT CONCRETE TOPPING ROOF STRUCTURE, TYP. EXISTING TAPERED RIGID INSULATION

EXISTING SINGLE-PLY ROOF MEMEBRANE

1 1/

2

"

PROVIDE 1/2" STL. LATE SUPPORT FOR 18" GRANITE TOP. WELD TO EACH SIDE OF 3" PIPE COLUMN. PROVIDE SPACER BARS BETWEEN BRACKET PLATES

PROVIDE 1/2" DUROCK ON ALL MTL. STUD FRAMING AS SHOWN FIBER CEMENT PANELS ON 1 1/2" MTL. CHANNELS 3" PIPE COLUMN -SEE PLAN FOR LOCATION

1" THK GRANITE TYPE TOP W/ 2" EDGING DETAIL

PROVIDE 1/2" DUROCK AT TOP PROVIDE POSITIVE SLOP FOR DRAINAGE

1/2" DUROCK SHEATHING AT ALL SURFACES OF GAV. MTL. STUD CONSTRUCTION

3.5 GAV, MTL STUDS 12" O.C. FOR WALL CONSTRUCTION

3.5 GAV, MTL STUDS 16" O.C. FOR BASE OF BAR CONSTRUCTION

FLOOR LEVELERS FOR 2" PAVERS E.I.F.S. ON DUROCK

EXISTING CONCRETE PLANKS EXISTING CONCRETE TOPPING EXISTING RIGID INSULATION

A6.1

3

1' 6" AB O V E TO P P IN G 1' AB O V E T O PP IN G 3 ' ABO VE PA VERS 3 ' AB OVE P AVES 2'-0 1/2" 2'-1 1/2" 1'-6 1/2"

FIBER CEMENT PANELS ON 1.5" MTL. FURRING CHANNELS PROVIDE 1/2" DUROCK ON ALL MTL. STUD FRAMING AS SHOWN

S.M. COPING OVER WALL TOP

FASTEN METL STUDS TO 3" PIPE COLOUMN

SEE PLAN FOR LOCATION\ 1" THIK. GRANITE TYP TOP W/ 2" EDGING DETAIL

PROVIDE 1/2" DUROCK AT TOP PROVIDE POSITIVE SLOPE FOR DRAINAGE

PROVIDE 1/2" DUROCK SHEATHING AT ALL SURFACES OF GAL. MTL. STUD

CONSTRUCTION

3 5/8" GAV. MTL. STUDS @ 12" O.C. FOR WALL CONSTRUCTION OF BAR UNIT

3 5/8" GAV. MTL. STUDS @ 16" O.C. FOR BASE OF BAR UNIT

FLOOR LEVELERS FOR 2" PAVERS

EXISTING CONCRETE PLANKS EXISTING CONCRETE TOPPING EXISTING RIGID INSULATION

A6.1

3

1' AB O V E T O PP IN G 3 ' ABO VE PA VERS 2'-1 1/2" 6'10 HIG H W A LL 2'-5 1/16" 2'-0 7/16"

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

G

ADHESIVE ANCHOR - SEE STRUCTUAL STEEL ANGEL -SEE STRUCTUAL 1/2"x1/2" STEEL BARS STEEL RAIL -SEE STRUCTUAL EXISTING RIGID INSULATION CL CL 1' -0 " 4" NEW CONCRETE PAVERS ON LEVELERS, TYP. EXST'G CONSTRUCTION, TYP. 1" 2"

TYPICAL END SECTION 8' SECTIONS 1'-4"

A6.1

3

G R EEN SCRE EN PANELS

TYPICAL MIDDLE SECTION 8' SHOP MADE SECTIONS

9"

1'

-0

"

3x3 PIPE COLUMN PRE DRILLED HOLES

TO RECIVE ANCHORS -VERIFY SIZE OF ANCHORS WITH STRUCTUAL 9 1/2" STEEL RAIL -SEE STRUCTUAL STEEL ANGLE -SEE STRUCTUAL BOLT ADJOING SECTIONS TOGETHER DOUBLE ANGLE ON END SECTIONS 9 1/2" 8" 4" 4"

TYP.

1/2"x1/2" STEEL BARS 4" 4" UNDERLAYMENT BOARD

PROVIDE MEMBRANE FASTENERS PER ROOF MEMBRANE MFR REQUIREMENTS. SINGLE-PLY FLASHING. PROVIDE TERMINATION BAR AND WATER CUT-OFF MASTIC AT T/PLYWOOD.

FLASHING W/ DRIP EDGE

EXPANSION BOLTS, SEE STRUCT. DWGS. CONT RUNNER TRACK CONT SILL SEALER SEALANT

3/4" TREATED EXT. PLYWOOD

METAL FLASHING

EXISTING HOLLOW-CORE CONCRETE PLANK w/ LIGHT-WEIGHT CONCRETE TOPPING ROOF STRUCTURE, TYP. EXISTING SINGLE-PLY ROOF MEMEBRANE

1'

-0

"

T/ SILL

SEE WALL SECT.

PRECAST CONC. PAVER ON LEVELER, SEE PLAN FOR SIZE AND HEIGHT

REMOVE EXISTING INSULATION TO INSTALL POST BASEPLATE, FILL VOID WITH LOW EXPANSION FOAM INSULATION, REPLACE SINGLE-PLY ROOF MEMBRANE

EXT. DOOR, SEE SCHEDULE UNDERLAYMENT BOARD

PROVIDE MEMBRANE FASTENERS PER ROOF MEMBRANE MFR REQUIREMENTS.

SINGLE-PLY FLASHING. PROVIDE TERMINATION BAR AND WATER CUT-OFF MASTIC AT T/ PLYWOOD. MTL. FLASHING w/ DRIP EDGE

3/4" TREATED EXT. PLYWOOD

EXISTING HOLLOW-CORE CONCRETE PLANK w/ LIGHT-WEIGHT CONCRETE TOPPING ROOF STRUCTURE, TYP. EXISTING SINGLE-PLY ROOF MEMEBRANE

PRECAST CONC. PAVER ON LEVELER, SEE PLAN FOR SIZE AND HEIGHT

REMOVE EXISTING INSULATION TO INSTALL POST BASEPLATE, FILL VOID WITH LOW EXPANSION FOAM INSULATION, REPLACE SINGLE-PLY ROOF MEMBRANE 6" 1' -3 " 2 PIECE MTL COUNTER-FLASHING. NO SEALANT.

FIBER CEMENT PANEL RAINSCREEN WALL, SEE WALL SCHEDULE

NO SEALANT METAL FLASHING

DRIP EDGE MTL FLASHING

SEALANT EACH SIDE EXT. DOOR, SEE

SCHEDULE DOOR FRAME PREFINISHED MTL. COPING SINGLE-PLY ROOFING SYSTEM 6" 1/4" 1/4" 4" NOTE:

ASSEMBLY FASTENED w/ SCREWS

ANCHOR COPING AT MIDSPAN ONLY (2) LAYERS 3/4" GYP. BRD SHEATHING, SEE WALL SCHEDULE

LAP ROOFING UP AND OVER PARAPET TO FRONT PANEL SYSTEM WEATHER MEMBRANE

1/2" EXT. GRADE PLYWOOD

3/4" EXT. PLYWOOD w/ 1-3/8"x6" LONG ANCHOR BOLT @ 48" 0.C.

WOOD BLOCKING

FIBER CEMENT PANEL RAINSCREEN WALL, SEE WALL SCHEDULE

T/ PARAPET WALL

SEE WALL SECT.

T/ ROOF

SEE WALL SECT.

B/ CEILING

SEE WALL SECT.

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A6.1

09/24/08

DETAILS

1 1/2" = 1'-0"

3

COLUM CONNETION DETAIL

GREEN SCREEN DETAILS

1 1/2" = 1'-0"

4

DETAIL - CONCRETE PAVER LEVEL

CHANGE

3/4" = 1'-0"

2

DETAIL THROUGH BAR

3/4" = 1'-0"

1

DETAIL THROUGH GRILL

PARAPET GUARD RAIL

1 1/2" = 1'-0"

7

Drafting 1

1 1/2" = 1'-0"

8

Copy of Drafting 1

Drafting 2

#

Description

Date

(10)

5

6

A

B

C

1

A5.1

5.3

4'-6" 6'-8" 3'-0" 1 1/2" 4 1/2" 3" , TY P . 2" 1 1/ 2 " 6' -5 " 1 1/ 2 " 11" 10" 4'-6" 10" 10" 10" 10" 10" 10" 10" 10" 3'-0" 1 1/2" 3" 1 1/2" 3' -0 " 1 1/ 2 " 2" 1 1/ 2 " 3' -0 " 6 1/ 2 " 8' -0 " 4 1/2"

RUN STRINGER CHANNEL PAST VERTICAL TUBE COLUMN AND WELD CONNECTION STEEL MC12x10.6 STRINGER,

EACH SIDE, FLANGE TURNED-OUT

11"

3x3x1/4" TS COLUMN, LANDING SUPPORT, HOLD TIGHT AGAINST EXT. WALL +/- 2" SPACE BETWEEN

CHANNEL STRINGER AND STONE VENEER WALL

8"

6'

-2

"

STEEL MC12x10.6 LANDING SUPPORT, FLANGE TURNED-OUT

HANDRAIL, EACH SIDE, SEE DETAIL

MEDIA CLOSET

N722

N722

4' -2 " 4'-6" 6" 3" +/- 3" STONE VENEER ON MTL STUD AND GYP. BRD FURRING, SEE MANUF. RECOMMENDED DETAILS FOR INSTALLATION +/- 3" STONE VENEER ON MTL

STUD AND GYP. BRD FURRING, SEE MANUF. RECOMMENDED DETAILS FOR INSTALLATION

UP 18R

4

A6.2

1/2x1/2" STEEL RAILING WELDED TO SUPPORTS MC12x10.06 STEEL STRINGER, EACH SIDE 1/2 x 1-1/2" STEEL BAR RAILING SUPPORTS WELDED TO STRINGER 3"x1-1/2" WD HANDRAIL, MATCH TREADS

1/4" STL. BENT PLATE, TYP.

L ESS TH AN 4" 2 '-10" 1 1/2" LE SS TH AN 4" TREAD BRACKET NOTE:

- STEEL STAIR ASSEMBLY (STRINGER, SUPPORTS, TREAD AND RISER PAN, ETC.) BY STEEL STAIR MANUFACTURER

- ALL EXPOSED STEEL TO HAVE POWDER COAT PAINT, U.N.O.

2" WOOD TREAD, SECURE TO PLATE FROM BELOW 11" 1"

5

6 7

A

C

D

1

A5.1

5.3

DN 18R

3" 4'-5" 6'-8" 3'-0" 1 1/2" 3" 3 1/2" +/- 2" SPACE BETWEEN

CHANNEL STRINGER AND STONE VENEER WALL

STEEL MC12x10.6 LANDING SUPPORT, FLANGE TURNED-OUT

HANDRAIL, EACH SIDE, SEE DETAIL

+/- 3" STONE VENEER ON MTL STUD AND GYP. BRD FURRING, SEE MANUF. RECOMMENDED DETAILS FOR INSTALLATION +/- 3" STONE VENEER ON MTL

STUD AND GYP. BRD FURRING, SEE MANUF. RECOMMENDED DETAILS FOR INSTALLATION

R1-1

42" GUARD RAIL, SEE DETAIL

NO HANDRAIL

EDGE OF STAIR OPENING, SEE DETAIL

4

A6.2

T/ EXST'G ROOF

CONC. TOPPING

79'-0"

T/ EXST'G

PARAPET

82'-8"

T/ 7th FLR CONC.

TOPPING

68'-4"

5

6

7

B/ STAIR TOWER

CEILINGS

86'-9 3/4"

5.3

T/ NEW STAIR

WALL PARAPET

89'-0"

80'-0"

- SEE SCHEDULE

NEW EXTERIOR WALL, TYP. (UL# U490 - MIN. 3hr.) NEW 48x48" OUTSIDE CURB

DIMENSION PYRAMID SKYLIGHT BY "KALWALL"; COORDINATE CURB w/ SKYLIGHT MANUF. DTLS., TYP. NEW STAIR TOWER ROOF

(MIN. 2hr RATED - UL# P723) - (1) SINGLE-PLY ROOF MEMBRANE - MIN. 2" RIGID INSULATION, SLOPE 1/4"/FOOT TOWARDS EAST WALL - (1) 1/4" RECOVERY BOARD - (1) 1 1/2" MTL. DECK, SEE STRUCT. - 10" CFS MTL. JOIST, SEE STRUCT. - (1) 1-5/8" MTL FURRING CHANNEL - (1) 5/8" GYP. BRD. EXST'G CONC. PLANK TO REMAIN TO T H E B/ F IN ISH ED C E IL IN G 6' -9 3/ 4 " 1 8 '-5 3 /4" - SEE SCHEDULE EXST'G WALL, TYP.(UL# U490 - MIN. 3hr.)

NEW PRIVATE STAIR LANDING - (1) 3/4" FINISH FLOOR - (2) 3/8" SUBFLOOR - 1 1/2" MTL. DECK - 8" CFS MTL. JOIST - 5" COMPOSITE DECK, SEE STRUCT. DWGS

8"

NEW PRIVATE

STAIR

NR001

NEW COMP. DECK LANDING AND STEEL FRAMING, SEE STRUCT

NEW DECORATIVE MTL. STAIR, SEE PLAN & DETAILS

STONE VENEER WALL BEYONE 3' -6 "

A6.2

2

Sim

11 '-8 " 5 '-10"

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A6.2

10/10/08

PRIVATE STAIR

DETAILS

1

ENLARGED PLAN - PRIVATE STAIR @

7th FLOOR

3/4" = 1'-0"

2

DETAIL - PRIVATE STAIR RAILING/

TREAD

3/4" = 1'-0"

3

ENLARGED PLAN - PRIVATE STAIR @

ROOF TERRACE

4

SECTION @ PRIVATE STAIR

(11)

2'-3" 2'-6" 4'-6" 4'-6" 4'-6" 2'-6" 2'-3" 1' -9 " 4 '-2 " 2' -1 " 2 '-1 " 4' -2 " 4 '-2 " 4' -7 " 5" ALUM. W-SECTION CL CL CL CL WEB 8" ALUM. W-SECTION w/ 5" FLANGE, TYP. TOP OF STAIR TOWER WALL BELOW CL 18'-6" 3'-3" CENTER OF COLUMN SUPPORTING W-SECTION

5

A7.1

3'-3" 25'-0" 5" ALUM. CHANNEL

3

A7.1

CL CL CL CL CL CL 23'-0" CL WEB 23 '-0 " 4x6' "GREENSCREEN" TRELLIS PANELS BY OTHERS 5" ALUM. W-SECTION 5" ALUM. W-SECTION 5" CHANNEL 10" ALUM. W-SECTION w/ 6" FLANGE

C

CL CL WEB 4'-2" 2'-1" 2'-1" 4'-2" 4'-2" 5" ALUM W-SECTION 3" "GREENSCREEN" TRELLIS PANELS BY OTHERS 8" ALUM. W-SECTION, TYP. 10" ALUM. W-SECTION w/ 6" FLANGE

1/2" ALUM PLATE WELDED ON TOP OF 3" ALUM. PIPE COLUMN WELDED TO 1/2" ALUM PLATE WELDED TO THE TOP OF W-SECTION COLUMN 8" ALUM. W-SECTION COLUMN 6" MTL STUD BEARING WALL

A7.1

4

2 1/ 2 " 5 1/ 2 " 2'-6" 23'-0" CL CL CL WEB 5 1/ 2 " 2 1/ 2 " 2'-6" CL CL 1'-2 1/2" 8'-0" 9'-2 1/2" 5'-9 1/2"

1/2" ALUM PLATE WELDED ON TOP OF 3" ALUM. PIPE COLUMN WELDED TO 1/2" ALUM PLATE ATTACHED TO 6" MTL. STUD BEARING WALL

3"

10"

7"

9'-2 1/2" 4 1/2"

# 5132A "GREENSCREEN" MOUNTING CLIP BY OTHER

STAINLESS STEEL SELF-TAPPING TEK SCREW 8" ALUM. W-SECTION BEAM 3" "GREENSCREEN" TRELLIS PANELS BY OTHER BOLTED CONNECTION 5" ALUM. W-SECTION BEAM 5" ALUM W-SECTION CL CL CL CL CL CL 4" 6" 2'-6" 8" ALUM W-SECTION w/ 5" FLANGE, TYP. 2'-6" 4'-6" 4'-6" 4'-6" 2'-6" 10" ALUM W-SECTION w/ 6" FLANGE 3'-3" 18'-6" 3'-3" 25'-0" 4" 6" 2'-6"

Sample

set

PROJECT NUMBER SHEET NUMBER P R O JE C T /O W N E R IN F O R M A TIO N DATE SHEET NAME PROJECT TRACKING

Chicago, Illinois

Interior Remodal and New Private Roof Terrace

Sample Commercial

08-R113

A7.1

09/16/08

ALUMINUM TRELLIS

DETAILS

3/8" = 1'-0"

2

ALUM. TRELLIS - PLAN

3/4" = 1'-0"

3

ALUM. TRELLIS - TRANSVERSE

SECTION, TYP.

3" = 1'-0"

4

TRELLIS CONNECTION DETAIL

1

ALUM TRELLIS - 3D VIEW

5

SeALUM. TRELLIS - LONGITUDINAL

SECTION, TYP.

References

Related documents

When you enter the maintenance mode, the unit price display windows show "F - - ", the money display window shows the software version number, and the volume display

Grand Marine Benelux BV behoudt zich het recht voor specificaties, standaard uitrusting, prijzen, kleuren en modellen zonder voorafgaande kennisgeving te wijzigen.. Voor

Novo button When the computer is off or in hibernation mode, press this button to start the Lenovo OneKey Recovery system or the BIOS setup utility, or to enter the boot menu..

Note: The dummy card is used for preventing dust and small particles from entering the inside of your computer when the memory card slot is not in use.. Retain the dummy card

This policy was prepared as part of the Level 1 FIPS 140-2 validation for the Cisco Unified IP Phone 7900 Series.. FIPS 140-2 (Federal Information Processing Standards Publication

In case of creation of new WebPages in English language, it shall be treated equivalent to Type A1 and Type A2 of PART I (Development -Designing/ Redesigning/ Refurbishing of

Stitch the two seams as you have stitched before with the center front seam, matching up the right raw edge lines up with the right outside edge of the presser foot.. Ever so

Then, to progress towards an understanding of the bronze “bathtub” coffin burials within the broader context of regional funerary practices, they are incorporated into an