Five pervasive flash-based storage myths

lashhasrapidly

moved from a niche

stor-age product that was used to differentiate

storage vendors to a ubiquitous

technol-ogy. The majority of success around flash

storage has come from the need -- or perceived need -- for speed by

mission-critical applications. This e-guide highlights the five most

pervasive myths about flash-based storage with an added dose of

reality.

(3)

Home

Five pervasive flash-based storage myths

FIVE PERVASIVE FLASH-BASED STORAGE MYTHS

Marc Staimer

Flash has rapidly moved from a niche storage product that was used to differ-entiate storage vendors to a ubiquitous technology. The majority of success around flash storage has come from the need -- or perceived need -- for speed by mission-critical applications. Here is a list of the five most pervasive myths about flash-based storage with an added dose of reality.

MYTH 1: HYBRID OR ALL-FLASH ARRAYS SOLVE ALL STORAGE-BASED PERFOR-MANCE PROBLEMS

Hybrid and all-flash arrays are all the rage in the data storage industry. For ex-ample, flash-based storage adds hundreds of thousands to millions of potential IOPS plus huge gains in throughput. But do these arrays solve all storage-based performance problems? No.

The issue is latency. Putting all those high-performance flash solid-state drives (SSDs) inside the storage array increases the latency between the stor-age controller and the drive media, typically by multiple orders of magnitude.

(4)

Home

Five pervasive flash-based storage myths

But it does nothing for the latency between the application server (physical or virtual) and the storage array. This is the latency of the data packets going from server memory and over the storage bridge to the PCI Express (PCIe) controller, Fibre Channel/Ethernet/InfiniBand adapter, transceiver, cable, transceiver, switch/multiple switches, cable, storage adapter, PCIe bus, PCIe controller, bridge, memory and CPU, and then back over the bridge to the PCIe controller, PCIe bus, SAS controller, transceiver, cable, transceiver, SSD con-troller and so on. That's a lot of latency that flash SSD performance is unable to improve. Additionally, flash SSDs can be constrained by the performance limitations of the storage controller.

When the lowest possible latency is essential to application performance (high-frequency trading, simulations, media and entertainment, flow analysis, modeling, 3-D CAD/CAM), flash SSD performance is best served directly from the application server's DIMM slots or PCIe slots. This eliminates the vast majority of the latency.

MYTH 2: FLASH DRIVES IN ARRAYS ARE MORE ENTERPRISE-READY THAN THOSE IN SERVERS

(5)

Home

Five pervasive flash-based storage myths

Array vendors test, burn-in and certify that all the drives in their arrays reduce drive failures, maintenance costs, downtime and lost data -- which is a very good thing. But flash SSDs and hard disk drives (HDDs) are quite different. Burning-in HDDs allows vendors to remove bad HDDs before they go out the door. But burning-in SSDs typically only provides the limited benefit of causing SSD performance to drop to the steady state sooner. The other claim is from array-based error correcting code that goes beyond that provided by the SSD.

Technically, there is a slight advantage to users when SSDs are embedded in an external array. But are these two items enough to claim that SSDs in a hybrid or all-flash array are more enterprise-ready than those embedded in servers? That's a subjective decision not necessarily related to the facts.

MYTH 3: SSDS COST A LOT MORE THAN HDDS

This perception has been around since the first SSDs hit the market, and it de-pends on several factors. First, it is based primarily on acquisition costs. Flash-based storage costs are dropping quickly, while the price of HDDs is falling much more slowly. As NAND flash manufacturers made NAND chips smaller and smaller following the Moore's law curve, acquisition price per gigabyte (GB) plummeted. As flash SSD manufacturers harden enterprise multi-level

(6)

Home

Five pervasive flash-based storage myths

cell and MLC NAND chips with better ECC and wear-leveling, price per GB has decreased even further. And as 3-D NAND makes its way into flash SSDs, acquisition costs will again drop dramatically per GB.

What does this mean when comparing SSDs to HDDs? High-performance 15,000 rpm and even 10,000 rpm HDDs are going away. Acquisition costs have become comparable while operating costs are definitively lower for SSDs. IBM recently determined that SSDs have an 11% lower acquisition cost than equiva-lent high-performance HDDs and a 28% lower total cost of ownership (TCO). Even as SSDs have relegated higher-performance HDDs to an increasingly smaller market share, large-capacity, lower performance 7,200 rpm HDDs have become increasingly popular for secondary storage applications such as active archive, backup, online analytical processing, big data/big data processing and compliance. How do flash-based SSDs compare to HDD costs in these applica-tions? Most IT pros will infer "not as well," and they would be correct.

The largest capacity HDD shipping today is 8 TB in a 3.5-inch form fac-tor. The largest capacity read-optimized SSD shipping this summer is 8 TB in a 2.5-inch form factor. Acquisition costs favor the HDD by a factor of 10. But power, cooling, rack space, floor space, weight and serviceability (among other factors) favor the SSD. And when deduplication and compression are applied

(7)

Home

Five pervasive flash-based storage myths

to those SSDs, the TCO cost curve shifts markedly to the SSD. (Note: Dedupli-cation/compression is currently an external array feature. That will be part of the software-defined data center in the near future.) So, do SSDs cost a lot more than HDDs? No. Do they cost more than HDDs? Sometimes, and sometimes they cost less.

MYTH 4: HYPER-CONVERGED SYSTEMS CANNOT BE ALL-FLASH

This belief stems from when initial hyper-converged systems did not support an all-flash SSD configuration. But that changed with the release of VMware vSphere 6.0 and VSAN 2.0. Hyper-convergence based on the latest VMware software does support all-flash SSD configurations. In fact, Dell is now selling all-flash hyper-converged systems.

MYTH 5: FLASH SSDS ARE FASTER THAN HDDS

Ask an IT pro if SSDs are faster than HDDs and few, if any, will disagree. In the vast majority of use cases, SSDs are faster than HDDs. However, there are specific circumstances when that is not true. SSDs will almost always provide more random IOPS at lower latencies than HDDs except when flash storage is closing in on the end of its flash write wear-life. Another case where this

(8)

Home

Five pervasive flash-based storage myths

statement does not hold true is for sequential reads and writes. HDD perfor-mance shines for sequential reads and writes. The SSD-to-HDD perforperfor-mance differential in sequential reads and writes is nominal.

(9)

Home

Five pervasive flash-based storage myths

FREE RESOURCES FOR TECHNOLOGY PROFESSIONALS

TechTarget publishes targeted technology media that address your need for information and resources for researching prod-ucts, developing strategy and making cost-effective purchase decisions. Our network of technology-specific Web sites gives you access to industry experts, independent content and analy-sis and the Web’s largest library of vendor-provided white pa-pers, webcasts, podcasts, videos, virtual trade shows, research reports and more —drawing on the rich R&D resources of technology providers to address market trends, challenges and solutions. Our live events and virtual seminars give you ac-cess to vendor neutral, expert commentary and advice on the issues and challenges you face daily. Our social community IT Knowledge Exchange allows you to share real world information in real time with peers and experts.

WHAT MAKES TECHTARGET UNIQUE?

TechTarget is squarely focused on the enterprise IT space. Our team of editors and net-work of industry experts provide the richest, most relevant content to IT professionals and management. We leverage the immediacy of the Web, the networking and face-to-face op-portunities of events and virtual events, and the ability to interact with peers—all to create compelling and actionable information for enterprise IT professionals across all industries and markets.

References

Related documents

Porque sólo después de haber comprendido hasta qué punto somos amados, después de haber reconocido el «don de Dios» para uno mismo y para los demás, se puede oír

deployed the market leading all flash array selected Nimble Storage, deploying multiple all flash arrays for a high performance virtual environment as part of a Unified Flash

Using a virtual storage appliance and local SSDs, or a flash based local caching solution, could lead to increased performance and decreased latency.. Storage Design

Higher storage costs and integration difficulties associated with Flash memory and solid state disks (SSDs) also rank high among the factors discouraging organizations from

It explains how companies can utilize Flash technology and the Solaris ZFS™ file system to take advantage of the high performance of enterprise solid state drives (SSDs) and the

 Flash can replace DRAM for cache and memory  Flash SSDs are built for enterprise storage  Flash storage is 10 times more expensive than hard disk drives  Flash storage

Ideal for virtual desktop infrastructure (VDI), virtual server infrastructure, big data, analytics and mixed workload consolidation, Flash storage arrays provide predictable

However, thanks to the declining cost of NAND flash media and system level advancements, IDC believes that SSDs and solid state technology will become pervasive