(2)

Remark Date

Modification Version

Ver.1.0 Release SINGLE Big Ceiling for Colombia (R410A, 60Hz, C/O) TDB ’16.09.30.

History

(3)

(1) (2) (3) (4) (5) (6) (7) (8) Buyer

Nomenclature

Indoor Units Model Names

AC 036 K N C D K C CB

(1) Classification

AC SINGLE

(2) Capacity

(3) Version

(4) Product Type

kBtu/h (3 digits)

F H J

2013 2014 2015

K 2016

N Indoor Unit

X Outdoor Unit

(5) Product Notation

4 4Way Cassette S

N 4Way Cassette(600x600)

L M M C J

LSP Duct MSP Duct LSP Duct Ceiling Console

(6) Feature

F P D S

Flagship Premium Deluxe Standard

(7) Rating Voltage

C K

208~230V, 60Hz, 1Ф 220~240V, 50/60Hz, 1Ф

(8) Mode

H C

Heat Pump (R410A)

Cooling Only (R410A)

(4)

(1) (2) (3) (4) (5) (6) (7) (8) Buyer

Nomenclature

Outdoor Units Model Names

AC 036 K X A D K C CB

(1) Classification

AC SINGLE

(2) Capacity

(3) Version

(4) Product Type

kBtu/h (3 digits)

F H J

2013 2014 2015

K 2016

N Indoor Unit

X Outdoor Unit

(5) Product Notation

A INV+SIDE+General Temp.

B Non-INV+SIDE+General Temp.

4 C

4Way Cassette Only Ceiling Only

(6) Feature

F P D S

Flagship Premium Deluxe Standard

(7) Rating Voltage

E K G

220~240V, 50Hz, 1Ф 220~240V, 50/60Hz, 1Ф

380~415V, 50Hz, 3Ф

(8) Mode

H C

Heat Pump (R410A)

Cooling Only (R410A)

(5)

Contents

1 Specifications 2

3 4 5 6 7 8

Capacity table

Dimensional drawing (Indoor) Electrical wiring diagram (Indoor) Sound pressure level (Indoor)

Temperature and air flow distribution (Indoor) Electrical wiring diagram (Outdoor)

Sound pressure level (Outdoor) 9

10 11

Piping diagram (Outdoor)

Dimensional drawing (Outdoor)

Capacity correction (Outdoor)

(6)

Specifications

Big Ceiling

1

NOTE

* Specifications may be subject to change without prior notice.

1) Nominal capacity are based on ( Refrigerant Piping : 5m(16.4ft), Level Differences : 0m(0ft) );

. Cooling : Indoor temp. 27ºC DB, 19ºC WB (80.6ºF DB, 66.2ºF WB) / Outdoor temp. 35ºC DB, 24ºC WB (95ºF DB, 75.2ºF WB) . Heating : Indoor temp. 20ºC DB, 15ºC WB (68°F DB, 59°F WB) / Outdoor temp. 7ºC DB, 6ºC WB (44.6°F DB, 42.8°F WB) 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

3) These products contain R410A which is fluorinated greenhouse gas.

Big Ceiling AC036KNCDKC/CB AC036KXADKC/CB

- COOLING ONLY

kW 2.73 / 9.82 / 11.14

Btu/h 9,300 / 33,500 / 38,000

US RT 0.78 / 2.79 / 3.17

kW -

Btu/h -

US RT -

0.65 / 3.30 / 4.70 - 4.00 / 16.00 / 21.50

-

A 26.7

A 30

- 2.98

(Btu/h)/W 10.15

- -

Energy Grade (C) E

Energy Grade (H) -

Φ, mm 9.52

Φ, inch 3/8"

Φ, mm 15.88

Φ, inch 5/8"

m 50

ft 164

m 30

ft 98

- -

- 0.75 ~ 1.25

- R410A

- -

kg 1.5

lbs 3.31

Φ, #, V, Hz 1,2,220-240,60

- Sirroco

Output x n W 153 x 1

CMM 26.00 / 23.00 / 19.00

CFM 918 / 812 / 671

Min / Std / Max mmAq -

Drain Φ,mm VP25 (OD 32,ID 25)

High / Mid / Low 48 / 44 / 40

Cooling -

kg 33.0

lbs 72.75

kg 39.0

lbs 85.98

mm 1,350 x 235 x 675

inch 53.15 x 9.25 x 26.57

mm 1,439 x 321 x 758

inch 56.65 x 12.64 x 29.84

- -

kg -

lbs

kg -

lbs

mm -

inch

mm -

inch

- -

mm/liter/h -

Air Filter - -

Φ, #, V, Hz 1,2,220-240,60

- Tw in BLDC Rotary

- UG8T300FUBJU

kW 2.82

Oil - PVE

CMM 50.00

CFM 1,766

Cooling 52

Cooling -

kg 62.0

lbs 136.69

kg 66.0

lbs 145.51

mm 880 x 967 x 320

inch 34.65 x 38.07 x 12.60

mm 1,047 x 1,045 x 415

inch 41.22 x 41.14 x 16.34

ºC -15~50

ºF 5 ~ 122

ºC -

ºF -

dB(A) Sound Pow er Level

External Dimension

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD) Outdoor

Unit

Pow er Supply

Compressor Type Model Output

Type

Fan Air Flow Rate Cooling

Sound Data Sound Pressure Level

Operating Temp. Range

Cooling

Heating

Shipping Dimensions (W×H×D)

Additional Accessories

Drain pump Drain pump

Max. Lifting Height / Displacement

dB(A) Sound Pow er Level

External Dimension

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD) Indoor

Unit

Pow er Supply

Fan

Type Motor

Air Flow Rate High / Mid / Low

External Static Pressure Drain Pipe

Sound Data Sound Pressure Level

Panel Size

Panel model

Panel Net Weight

Shipping Weight

Net Dimensions (W×H×D) Field

Wiring

Pow er Source Wire Transmission Cable

Refrigerant Type Control Method

Factory Charging Piping

Connections Liquid Pipe

Gas Pipe

Installation Limitation

Max. Length (Outdoor to indoor)

Max. Height (Betw een ID/OD) Energy

Efficiency

EER (Nominal Cooling) EER (Nominal Cooling, US) COP (Nominal Heating)

Energy Grade

Cooling (Min / Std / Max) Heating (Min / Std / Max) A

MCA MFA Type

Model Name Indoor Unit

Outdoor Unit

System Mode

Capacity

Cooling (Min / Std / Max)

Heating (Min / Std / Max)

Pow er

Pow er Input (Nominal)

Cooling (Min / Std / Max) Heating (Min / Std / Max) kW

Current Input (Nominal)

(7)

Capacity table

Big Ceiling

AC036JNCDKC/CB + AC036JXADKC/CB

Cooling

TC(Total Capacity), SHC(Sensible Heat Capacity), PI(Power Input)

* Capacity table may be subject to change without prior notice.

1) Capacities are based on following conditions;

. Refrigerant piping length : 5m(16.4ft) / Level difference : 0m(0ft).

2

TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI

MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW

-15 33.30 26.60 1.58 34.10 27.30 1.62 34.90 28.00 1.66 35.80 28.60 1.70 36.25 28.95 1.72 36.70 29.30 1.74 37.50 30.00 1.78 21 38.10 30.50 2.67 39.10 31.20 2.73 40.00 32.00 2.80 41.00 32.80 2.87 41.50 33.20 2.91 42.00 33.60 2.94 43.00 34.40 3.01 35 32.50 26.00 3.14 33.30 26.70 3.22 34.20 27.30 3.30 33.50 25.80 3.30 35.40 28.35 3.42 35.80 28.70 3.46 36.70 29.40 3.54 43 25.70 20.50 2.98 26.30 21.00 3.05 26.90 21.60 3.13 27.60 22.10 3.20 27.95 22.35 3.24 28.30 22.60 3.28 28.90 23.20 3.36 50 18.20 14.60 2.57 18.70 14.90 2.63 19.10 15.30 2.69 19.60 15.70 2.76 19.85 15.90 2.80 20.10 16.10 2.83 20.60 16.40 2.89

14 (WB) 16 (WB) 18 (WB) 19 (WB) 20 (WB) 22 (WB) 24 (WB)

Outdoor temperature

(ºC, DB)

Indoor temperature (ºC)

20 (DB) 22 (DB) 25 (DB) 27 (DB) 28 (DB) 30 (DB) 32 (DB)

(8)

Dimensional drawing

Big Ceiling

AC036KNCDKC/CB

3

(9)

Electrical wiring diagram

Big Ceiling

4

AC036KNCDKC/CB

NOTE

1. This wiring diagram applies only to the indoor unit.

2. Symbols show as follow;

BLK : black, RED : red, BLU : blue, WHT:white, YEL : yellow, BRN : brown, SKY : sky-blue, GRN : green 3. For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remotecontroller transmission F3-F4.

4. Protective earth(screw)

(10)

Sound Pressure Level

Big Ceiling

Unit: dB(A) Model

AC036KNCDKC/CB (ODU : AC036KXADKC/CB)

Note

Specifications may be subject to change without prior notice.

Sound pressure level is obtained in an anechoic room.

Sound pressure level is a relative value, depending on the distance and acoustic environment.

Sound pressure level may differ depending on operation condition.

dBA = A-weighted sound pressure level Reference acoustic pressure 0 dB= 20 uPa

NC curve

1) AC036KNCDKC/CB (ODU : AC036KXADKC/CB)

5

High Low

48 40

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz) 10

15 20 25 30 35 40 45 50 55

Sound pressure level(dB)

(11)

Temperature and air flow distribution

Big Ceiling

AC036KNCDKC/CB

(1) Cooling air velocity distribution Discharge angle (Default) : 32º

(2) Cooling Temperature distribution Discharge angle (Default) : 32º

6

(12)

Electrical wiring diagram

Outdoor unit

7

AC036KXADKC/CB

NOTE

1. This wiring diagram applies only to the outdoor unit.

2. Symbols show as follow;

BLK : black, RED : red, BLU : blue, WHT:white, YEL : yellow, BRN : brown, SKY : sky-blue, GRN : green 3. For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remotecontroller transmission F3-F4.

4. Protective earth(screw)

(13)

Sound Pressure Level

Outdoor unit

Unit: dB(A) Model

AC036KXADKC/CB (IDU : AC036KNCDKC/CB)

Note

Specifications may be subject to change without prior notice.

Sound pressure level is obtained in an anechoic room.

Sound pressure level is a relative value, depending on the distance and acoustic environment.

Sound pressure level may differ depending on operation condition.

dBA = A-weighted sound pressure level Reference acoustic pressure 0 dB= 20 uPa

NC curve

1) AC036KXADKC/CB (IDU : AC036KNCDKC/CB)

8

Cooling 52 1.5m

1m

Front Microphone

63 125 250 500 1000 2000 4000 8000

Octave band center frequency(Hz) 20

25 30 35 40 45 50 55 60

Sound pressure level(dB)

(14)

Piping diagram

Outdoor unit

9

AC036KXADKC/CB

Electronic Expansion Valve - Main

(E_M) Thermistor

Cond Out (T_CO)

Outdoor Fan Motor 1 (OFM1) Thermistor

Ambient (T_A)

Heat Exchanger Indoor Unit (HX_ID)

Indoor Fan Motor (IFM)

AC036KNCDKC/CB Model

15.88(5/8") Service Valve - Gas pipe

(SV_G)

Service Valve - Liquid pipe (SV_L) Heat

Exchanger Main (HX_M)

Thermistor Indoor Room

(T_IR) Thermistor

IDU heat exchanger

Mid (T_IM)

Thermistor IDU heat exchanger In

(T_II)

Indoor Unit Outdoor Unit

Liquid pipe connection port

Ø A Gas pipe connection port

Ø B

9.52(3/8")

Thermistor Discharge pipe (T_D)

Compressor (COMP)

A B

Filter

Thermistor Compressor

Top

(T_CT)

(15)

Dimensional drawing

Outdoor unit

AC036KXADKC/CB

10

Units : mm / inches

Table of descriptions

1 Refrigerant gas pipe 7

2 Refrigerant liquid pipe 8

3 Power & Comm. wiring conduits 9

4 10

5 11

6 12

880 [2'-10 3/4"]

645 [2'-1 1/2"]

125 [5"]

364 [1' -2 1 /4 "] 340 [1' -1 1 /2 "]

52 [2"]

101 [4" ]

12 [1/2"]

578 [1'-10 3/4"]

965 [3 '- 2 "] 503 [1' -7 3 /4 "] 128 [5" ] 70 [ 2 3/ 4 "]

320

[1'-0 1/2"]

(16)

Capacity correction

Outdoor unit

AC036KNCDKC/CB + AC036KXADKC/CB

Cooling

11

Pipe Length (m)

5 10 15 20 25 30 35 40 45 50

Level Difference (m)

30 25 20 15 10 5 0 -5 -10 -15 -20 -25 -30

- - - - - 1.00 1.00 1.00 - - - - -

- - - - 0.99 0.99 0.99 0.98 0.98 - - - -

- - - 0.97 0.97 0.97 0.97 0.96 0.96 0.96 - - -

- - 0.96 0.96 0.96 0.96 0.96 0.95 0.95 0.95 0.94 - -

- 0.95 0.95 0.95 0.95 0.95 0.95 0.94 0.94 0.93 0.93 0.93 -

0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.93 0.93 0.93 0.92

0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.91 0.91 0.91 0.90

0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.90 0.90 0.89 0.89

0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.87 0.87 0.87 0.86 0.86

0.87

0.87

0.87

0.87

0.87

0.87

0.87

0.87

0.87

0.86

0.86

0.85

0.85

(17)

2016. 09.

Ver. 1.0

Samsung Electronics Co., LTD.

B2B PM / SE

Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677

Website : www.samsung.com btsp.samsunggsbn.com Email : [email protected]

Images and data in this book may subject to change without prior notice.

References

Related documents