Transmission Owner:
Submittal Date:
Substations or Switching Stations
Substation Name State Nominal
Max kV
Nominal Min kV
Sub ID
(Optional) Comments
Under MISO Functional Control (Appendix H)
or Non-Transferred Facilities (Appendix G)
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) H
Blytheville North AR 161 High-side facility only H
AECC Dell 161kV AR 161 High-side facility only H
Nucor-Yamato 161kV Switching Statioin AR 161 High-side facility only H
Nucor II AR 161 High-side facility only H
Bailey AR 161 69 High-side H, Low-side G H
Black Rock AR 161 High-side facility only H
Clinton West AR 161 69 High-side H, Low-side G H
Deluce AR 115 69 High-side H, Low-side G H
Dumas North AR 115 High-side facility only H
Glendale AR 115 High-side facility only H
Harrison South AR 161 High-side facility only H
Heber Springs North AR 161 69 High-side H, Low-side G H
Helena Industrial AR 115 High-side facility only H
HS9 Switching Station AR 161 High-side facility only H
Jacksonville South AR 115 High-side facility only H
Jonesboro West AR 161 69 High-side H, Low-side G H
McClellan AR 115 High-side facility only H
Midway-Jordan AR 161 69 High-side H, Low-side G H
Montrose East AR 115 High-side facility only H
Oppelo AR 161 High-side facility only H
July 25, 2017
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) and Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement
Arkansas Electric Cooperative Corporation
Submittal Date:
Substations or Switching Stations
Substation Name State Nominal
Max kV
Nominal Min kV
Sub ID
(Optional) Comments
Under MISO Functional Control (Appendix H)
or Non-Transferred Facilities (Appendix G)
July 25, 2017
Osage Creek AR 161 69 High-side H, Low-side G H
Palestine AR 161 69 High-side H, Low-side G H
Truman West AR 161 69 High-side H, Low-side G H
Ward AR 115 High-side facility only H
Wynne East AR 161 69 High-side H, Low-side G H
AECC Dell 500kV AR 500 161 High-side H, Low-side H H
Wabbaseka West AR 115 13.2 High-Side facility only H
Barfiled AR 161 4.16 High-Side facility only H
HS9 Switching Station AR 115 High-side facility only H
Balch AR 161 13.20 High-side facility only H
HS2 Switching Station AR 115 High-side facility only H
Barfield AR 161 High-side facility only H
Balch AR 161 High-side facility only H
Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement. G Cotton Plant
AR 69
13.2
High-Side facility only-Per ER13948
G
Keevil
AR 69
13.2
High-Side facility only-Per ER13948
G
Moro
AR 69
13.2
High-Side facility only-Per ER13948
G
Transmission Owner:
Submittal Date:
Substations or Switching Stations
Substation Name State Nominal
Max kV
Nominal Min kV
Sub ID
(Optional) Comments
Under MISO Functional Control (Appendix H)
or Non-Transferred Facilities (Appendix G)
July 25, 2017
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) and Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement
Arkansas Electric Cooperative Corporation
Palestine Dist.
AR 69
13.2
High-Side facility only-Per ER13948
G
Coop Office
AR 69
13.2
High-Side facility only-Per ER13948
G
Wynne Switching Station
AR 69
13.2
High-Side facility only-Per ER13948
G
Fair Oaks
AR 69
13.2
High-Side facility only-Per ER13948
G
Augusta
AR 69
13.2
High-Side facility only-Per ER13948
G
St. Francis
AR 69
13.2
High-Side facility only-Per ER13948
G
Earle
AR 69
13.2
High-Side facility only-Per ER13948
G
Marked Tree
AR 69
13.2
High-Side facility only-Per ER13948
G
McCormick
AR 69
13.2
High-Side facility only-Per ER13948
G
Lunsford
AR 69
13.2
High-Side facility only-Per ER13948
G
Submittal Date:
Substations or Switching Stations
Substation Name State Nominal
Max kV
Nominal Min kV
Sub ID
(Optional) Comments
Under MISO Functional Control (Appendix H)
or Non-Transferred Facilities (Appendix G)
July 25, 2017
Northwest Jonesboro
AR 69
13.2
High-Side facility only-Per ER13948
G
Apt
AR 69
13.2
High-Side facility only-Per ER13948
G
NOTE: ER13948 established authority to include facilities located along a contiguous transmission path.
Transmission Owner:
Submittal Date:
Transformers
Substation Name Transformer
ID
Nominal High Side kV
Nominal Low Side kV
Normal Summer
MVA Comments
Under MISO Functional Control
(Appendix H) or Non-Transferred Facilities (Appendix G)
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) H
AECC Dell 500kV Auto #1 500 161 250 H
AECC Dell 500kV Auto #2 500 161 250 H
AECC Dell 500kV Auto #3 500 161 250 H
Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement. G
Bailey Auto 161 69 100 G
Clinton West Auto #1 161 69 41.7 G
Clinton West Auto #2 161 69 100 G
Deluce Auto 115 69 41.7 G
Heber Springs North Auto #1 161 69 108 G
Heber Springs North Auto #2 161 69 41.7 G
Jonesboro West Auto 161 69 100 G
Midway-Jordan Auto #1 161 69 100 G
Midway-Jordan Auto #2 161 69 100 G
Palestine Auto 161 69 100 G
Truman West Auto 161 69 108 G
Wynne East Auto 161 69 100 G
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) and Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement
July 25, 2017
Arkansas Electric Cooperative Corporation
Transmission Lines
From Substation To Substation kV Circuit
ID
Length
(miles) State Line ID (Optional)
Line Name (Optional)
Segment #
(Optional) Comments
Under MISO Functional Control
(Appendix H) or Non-Transferred Facilities (Appendix
G)
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) H
AECC Dell 161kV Nucor-Yamato 161kV
Switching Station 161 1 14.79 AR Line 1 H
Nucor-Yamato 161kV Switching Station
Nucor II 161kV Switching
Station 161 1 6.21 AR Line 5 H
Nucor II 161kV Switching Station Hickman North 161 1 0.72 AR Line 9 H
Hickman North Blytheville North 161 1 8.67 AR Line 10 H
Nucor-Yamato 161kV Switching Station
Nucor II 161kV Switching
Station 161 1 5.36 AR Line 6 H
Nucor-Yamato 161kV Switching Station
Nucor II 161kV Switching
Station 161 2 5.34 AR Line 7 H
Nucor-Yamato 161kV Switching Station Barfield 161 1 0.44 AR Line 8 H
AECC Dell 500kV
Nucor-Yamato 161kV
Switching Station 161 1 14.82 AR Line 2 H
AECC Dell 500kV
Nucor-Yamato 161kV
Switching Station 161 2 15.87 AR Line 3 H
AECC Dell 500kV
Nucor-Yamato 161kV
Switching Station 161 3 15.89 AR Line 4 H
Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement. G
Bailey Cotton Plant 69 1 22.06 AR Per ER13948 G
July 25, 2017 Submittal Date:
Transmission Lines
From Substation To Substation kV Circuit
ID
Length
(miles) State Line ID (Optional)
Line Name (Optional)
Segment #
(Optional) Comments
Under MISO Functional Control
(Appendix H) or Non-Transferred Facilities (Appendix
G)
Transmission Owner: Arkansas Electric Cooperative Corporation
July 25, 2017 Submittal Date:
Transmission Facilities Transferred to MISO’s Functional Control Pursuant to Appendix H (Transmission System Facilities) and Non-transferred Transmission Facilities that are subject to Appendix G (Agency Agreement) of the Transmission Owners Agreement
Cotton Plant Keevil 69 1 17.41 AR Per ER13948 G
Keevil Moro 69 1 16.02 AR Per ER13948 G
Moro Palestine 69 1 16.38 AR Per ER13948 G
Palestine Coop Office 69 1 8.67 AR Per ER13948 G
Augusta (Bailey) Morton (Fair Oaks) 69 1 15.75 AR Per ER13948 G
Wynne St. Francis 69 1 10.03 AR Per ER13948 G
Earle St. Francis 69 1 7.53 AR Per ER13948 G
Marked Tree Earle 69 1 14.51 AR Per ER13948 G
Marked Tree McCormick 69 1 12.14 AR Per ER13948 G
McCormick Lunsord 69 1 4.00 AR Per ER13948 G
NW Jonesboro Jonesboro West 69 1 1.04 AR Per ER13948 G
Apt Northwest Jonesboro 69 1 7.61 AR Per ER13948 G
Apt Trumann West 69 1 6.70 AR Per ER13948 G
McCormick Trumann West 69 1 7.02 AR Per ER13948 G
NOTE: ER13948 established authority to include facilities located along a contiguous transmission path.