• No results found

Rack-Mount and Cable-Management Kit Installation Instructions

N/A
N/A
Protected

Academic year: 2021

Share "Rack-Mount and Cable-Management Kit Installation Instructions"

Copied!
26
0
0

Loading.... (view fulltext now)

Full text

(1)

Text Part Number:

Rack-Mount and Cable-Management Kit

Installation Instructions

Product Numbers: ACS-7200-RMK=, CISCO7204=, CISCO7206=, RS7206S=, RS7206VXR=, CISCO7202=, CISCO7204VXR=, CISCO7206VXR=

Introduction

This document explains how to install Cisco 7200 series routers in an equipment rack and how to install the cable-management brackets on the routers using the rack-mount and cable-management kit. The Cisco 7200 series routers consist of the 2-slot Cisco 7202, 4-slot Cisco 7204 and

Cisco 7204VXR, and the 6-slot Cisco 7206 and Cisco 7206VXR.

Note The Cisco 7206VXR and Cisco 7206 can be used as router shelves in a Cisco AS5800 Universal Access Server. References to the Cisco 7200 series routers in this document include the Cisco 7206VXR and Cisco 7206 as router shelves in a Cisco AS5800 Universal Access Server, unless indicated otherwise.

Contents

This document includes the following sections:

If You Need More Information, page 2

Rack-Mount and Cable-Management Kit Overview, page 3

Installation Prerequisites, page 3

Rack-Mounting Cisco 7200 Series Routers, page 10

Installing Cable-Management Brackets on Routers in Workbench or Tabletop Configurations, page 24

Securing Port Adapter Interface Cables to Cable-Management Brackets, page 24

Cisco Connection Online, page 25

(2)

If You Need More Information

If You Need More Information

Your router and the Cisco IOS software running on it contain extensive features and functionality, which are documented in the following resources:

Cisco Documentation CD-ROM package

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription.

If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

For Cisco IOS software configuration information and support, refer to the modular configuration and modular command reference publications in the Cisco IOS software

configuration documentation set that corresponds to the software release installed on your Cisco hardware.

For hardware installation and maintenance information on the Cisco 7200 VXR routers, refer to the Cisco 7200 VXR Installation and Configuration Guide that shipped with your router.

For hardware installation and maintenance information on the Cisco 7200 routers, refer to the following publications that shipped with your router:

— Cisco 7202 Installation and Configuration Guide — Cisco 7204 Installation and Configuration Guide — Cisco 7206 Installation and Configuration Guide

For hardware installation and maintenance information and software configuration information on the Cisco AS5800 Universal Access Server, refer to the following publications:

— Cisco AS5800 Universal Access Server Hardware Installation and Configuration Guide — Cisco AS5800 Universal Access Server Software Installation and Configuration Guide

For international agency compliance, safety, and statutory information for wide-area network

(WAN) interfaces for the Cisco 7200 series routers and the Cisco AS5800 Universal Access Server refer to the following publications:

— Regulatory Compliance and Safety Information for the Cisco 7200 Series Routers — Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information

For general information about documentation, refer to the section “Cisco Connection Online,”

on page 25, or call customer service at 800 553-6387 or 408 526-7208. Customer service hours are 5:00 a.m. to 6:00 p.m. Pacific time, Monday through Friday (excluding Cisco-observed holidays). You can also send e-mail to [email protected].

Note You can access Cisco IOS software configuration and hardware installation and maintenance documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

(3)

Rack-Mount and Cable-Management Kit Overview

Rack-Mount and Cable-Management Kit Overview

The Cisco 7200 series rack-mount and cable-management kit includes rack-mount brackets and cable-management brackets.

The rack-mount brackets are designed for mounting Cisco 7200 series routers in 19-inch, 4-post and telco-type equipment racks. The cable-management brackets are designed to relieve strain on port adapter interface cables that are installed on port adapters in Cisco 7200 series routers.

Note Eight removable tie wraps installed on the cable-management brackets secure port adapter interface cables to the brackets. We recommend that you use the tie wraps that shipped with the cable-management brackets. You can use standard tie wraps; however, you will have to cut and replace them with new tie wraps when you want to release or secure an interface cable to a bracket.

The cable-management brackets can be installed on Cisco 7200 series routers that are installed on a tabletop or workbench, or in a rack. The rack-mount and cable-management brackets are shipped with Cisco 7200 series routers and are also available as single field-replaceable units (FRUs).

Installation Prerequisites

This section provides a list of parts and tools you need to install the rack-mount and

cable-management brackets on Cisco 7200 series routers. This section also includes safety and ESD-prevention guidelines to help you avoid injury to yourself and damage to the equipment.

Tools and Parts Required

You will need the following parts and tools to install the rack-mount and cable-management brackets on your Cisco 7200 series router. If you need additional equipment, contact a service representative for ordering information.

Number 2 Phillips and a 3/16-inch flat-blade screwdriver

Tape measure (optional)

Level (optional)

The rack-mount and cable-management kit includes the following parts:

Two rack-mount brackets for mounting the chassis in the rack

Four M4 x 8-mm Phillips flathead screws to secure the rack-mount brackets to the chassis

Six 10-32 x 3/8-inch slotted binderhead screws to secure the rack-mount brackets to the rack rails

Two cable-management brackets to relieve the strain on installed port adapter interface cables

Four M4 x 8-mm Phillips flathead screws to secure the cable-management brackets to the chassis or the rack-mount brackets

(4)

Installation Prerequisites

Safety Guidelines

Following are safety guidelines that you should follow when working with any equipment that connects to electrical power or telephone wiring.

Warning Only trained and qualified personnel should be allowed to install or replace this equipment.

Safety Warnings

Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.

Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d’avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.

Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.

(5)

Safety Guidelines

Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.

Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.

Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.

¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.

Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.

Electrical Equipment Guidelines

Follow these basic guidelines when working with any electrical equipment:

Before beginning any procedures requiring access to the chassis interior, locate the emergency power-off switch for the room in which you are working.

Disconnect all power and external cables before moving a chassis.

Do not work alone when potentially hazardous conditions exist.

Never assume that power has been disconnected from a circuit; always check.

Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds.

(6)

Installation Prerequisites

Telephone Wiring Guidelines

Use the following guidelines when working with any equipment that is connected to telephone wiring or to other network cabling:

Never install telephone wiring during a lightning storm.

Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Chassis Lifting Guidelines

A fully configured Cisco 7200 series router weighs approximately 50 pounds. The chassis is not intended to be moved frequently. Before you install the router, ensure that your site is properly prepared, so you can avoid having to move the chassis later to accommodate power sources and network connections.

Whenever you lift the chassis or any heavy object, follow these guidelines (see Figure 1):

Always disconnect all external cables before lifting or moving the chassis.

Do not attempt to lift the chassis by yourself; have someone assist you.

Ensure that your footing is solid, and balance the weight of the object between your feet.

Lift the chassis slowly; never move suddenly or twist your body as you lift.

Keep your back straight and lift with your legs, not your back. If you must bend down to lift the chassis, bend at the knees, not at the waist, to reduce the strain on your lower back muscles.

Lift the chassis from the bottom; grasp the underside of the chassis exterior with both hands.

Warning To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules (such as power supplies, fans, or cards); these types of handles are not designed to support the weight of the unit. Lift the unit only by using handles that are an integral part of the chassis, or by grasping the chassis underneath its lower edge.

(7)

Rack-Mount Considerations

Figure 1 Lifting the Chassis—Cisco 7204 Shown

Warning Two people are required to lift the chassis. To prevent injury, keep your back straight and lift with your legs, not your back.

Rack-Mount Considerations

The rack-mounting hardware included with your Cisco 7200 series router is suitable for most 19-inch, 4-post and telco-type equipment racks. Some equipment racks provide a power strip along the length of one of the mounting strips. Figure 2 shows a typical 19-inch, 4-post equipment rack with a power strip along one of the back posts.

If your rack has a power strip, consider the position of the strip when planning fastener points to ensure that you will be able to pull port adapters and other FRUs straight out of their respective slots. If the power strip does impair a rear rack-mount installation, remove the power strip before installing the router in the rack, then replace it after the chassis is installed.

H7403

ENABLED MII LINK

FAST ETHERNET MEDIA ADAPTER

RJ45 0 ETHERNET 10BT ENABLED 02 13LINK 0 12 3 FAST SERIAL ENTDTCRDRCLB CDTDTCRDRCLB CDTDTCRDRCLB CDTDTCRDRCLB CD

ENABLED MIILINKRJ45 FAST ETHERNET

0

(8)

Installation Prerequisites

Figure 2 Typical 19-Inch Equipment Rack Posts and Mounting Strips

To use the rack-mounting hardware provided with your Cisco 7200 series router, consider the following guidelines:

To mount the router between two posts or rails using the brackets, the inner clearance (the width between the inner sides of the two posts or rails) must be at least 17.00 inches (43.18 cm).

The height of the chassis is 5.25 inches (13.34 cm)

When mounting the router in 4-post or telco-type racks, be sure to use all the screws and brackets provided to secure the chassis to the rack posts.

When planning your rack installation, consider the following guidelines:

If you are planning to install the cable-management brackets on Cisco 7200 series router that you are rack-mounting from the front, you must install the cable-management brackets and the rack-mount brackets before you install the chassis in the rack.

Install the router in an open rack whenever possible. If installation in an enclosed rack is unavoidable, ensure that the rack has adequate ventilation.

If you plan to use an equipment shelf, ensure that the shelf is constructed to support the weight and dimensions of the chassis. Figure 3 shows the chassis footprint, which you will need if you are designing a customized shelf. We recommend that you use the rack-mount kit designed for your router.

Allow sufficient clearance around the rack for maintenance. If the rack is mobile, you can push it back near a wall or cabinet for normal operation and pull it out when necessary for maintenance (installing or moving port adapters, connecting cables, or replacing or upgrading components). Otherwise, allow 19 inches (48.3 cm) of clearance to remove router FRUs.

18.312" hole C to C 17.00 " min. Rack posts Mounting strips 110 VAC outlets H6898

(9)

Rack-Mount Considerations

Maintain a minimum clearance of three inches on the left and right of the chassis for the cooling air inlet and exhaust vents, respectively. Avoid placing the router in an overly congested rack or directly next to another equipment rack; otherwise, the heated exhaust air from other equipment can enter the inlet air vents and cause an overtemperature condition inside the router.

Caution To prevent chassis overheating, never install your Cisco 7200 series routers in an enclosed rack or room that is not properly ventilated or air conditioned.

Always install heavier equipment in the lower half of a rack to maintain a low center of gravity and prevent the rack from falling over.

If you use telco-type racks, be sure that the rack is bolted to the floor and secured because in these types of installations only one end of the chassis mounts to the two rack posts. Ensure that the weight of the chassis does not make the rack unstable.

Figure 3 Cisco 7200 Series Router Footprint and Outer Dimensions

H6238

Card cage and I/O controller width 13.5 in. (34.29 cm) Network processing engine width

13.8 in. (35.05 cm)

Chassis depth (including cable service loop and port adapter cables) 26 in. (66.04cm)

Chassis depth 17.0 in. (43.18 cm)

Fan tray depth 15.81 in.

(40.16 cm)

Chassis width 16.8 in. (42.67 cm)

(10)

Rack-Mounting Cisco 7200 Series Routers

Rack-Mounting Cisco 7200 Series Routers

Note If you plan to install your Cisco 7200 series router on a tabletop or workbench, proceed to the “Installing Cable-Management Brackets on Routers in Workbench or Tabletop Configurations” section on page 24.

The chassis mounts to two rack posts with two brackets that attach to either the front or the rear sides of the chassis. If you want the port adapter end (the front) of the chassis recessed in the rack, install the rack-mount brackets at the front or rear of the chassis in the orientation shown in Figure 4. If you want the front of the chassis protruding from the rack, install the rack-mount brackets at the front or rear of the chassis in the orientation shown in Figure 5.

Figure 4 Installing the Chassis in a 4-post Rack—Front Installation (Cisco 7204 Shown)

ENABLED MIILINKRJ45 FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX H9156 Rack-mount bracket MIIENRJ45ENRJ45LINK1O PWROK RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECT SLOT 0

(11)

Rack-Mounting Cisco 7200 Series Routers

Figure 5 Installing the Chassis in a Telco-Type Rack—Front Installation (Cisco 7204 Shown)

If you plan to install the cable-management brackets on a Cisco 7200 series router that you are rack-mounting, you must install the cable-management brackets and rack-mount brackets on the chassis before you install the chassis in the rack.

There are two cable-management configurations when you rack-mount a Cisco 7200 series router from the front. In the first configuration, the cable-management brackets are installed over the rack-mount brackets, and four screws secure both sets of brackets to the chassis (see Figure 6). In the second configuration, two screws secure each rack-mount bracket to the chassis, and two additional screws secure each cable-management bracket to a rack-mount bracket (see Figure 7).

H9157

ENABLED MIILINKRJ45

FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX Rack-mount bracket MIIEN RJ45ENRJ45LINK1O PWROK RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECT SLOT 0

(12)

Rack-Mounting Cisco 7200 Series Routers

Figure 6 Rack-Mounting the Chassis in a Telco-Type Rack With Installed Cable-Management Brackets—Front Installation (Cisco 7204 Shown)

Figure 7 Rack-Mounting the Chassis in a 4-post Rack With Installed

Cable-Management Brackets—Front Installation (Cisco 7204 Shown)

H9239

ENABLED MIILINKRJ45

FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX Cisco 7200 SERIES Rack-mount bracket MIIENRJ45ENRJ45LINK1O PWROK RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECTSLOT 0

SLOT 1 FE MII

Cable-management bracket

ENABLED MIILINKRJ45 FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX H9238

MIIENRJ45ENRJ45LINK1O PWROK

RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECT SLOT 0

SLOT 1 FE MII

Rack-mount bracket

(13)

Powering Down the Router and Disconnecting Input Power

If you are rack-mounting a Cisco 7200 series router from the rear, the rack-mount brackets are installed at the rear of the chassis, and the cable-management brackets are installed at the front of the chassis. You must install both sets of brackets before you install the chassis in the rack. The following sections explain the procedure for rack-mounting the Cisco 7200 series routers:

Powering Down the Router and Disconnecting Input Power

Installing the Brackets on the Chassis

Installing the Chassis in the Rack

Reconnecting Input Power and Powering Up the Router These tasks are described in detail in the following subsections.

Note The tasks for rack-mounting the Cisco 7200 series routers and the Cisco 7206VXR and Cisco 7206 as router shelves in a Cisco AS5800 Universal Access Server are the same. Therefore, the illustrations in the following sections show the Cisco 7206, unless indicated otherwise.

Powering Down the Router and Disconnecting Input Power

If your router is already installed on a tabletop or workbench, or in a rack, you must power down the router and disconnect input power before attempting the rack-mount procedure. If your router is already installed in a rack with the original rack-mount brackets (brackets that were shipped before February 1997), you must also remove the original rack-mount brackets from the chassis.

Warning This unit might have more than one power cord. To reduce the risk of electric shock, disconnect the two power cords before servicing the unit.

Powering Down the Router

To power down Cisco 7200 series routers, complete the following steps:

Note Before powering down the router, use the copy running-config startup-config command to save the router’s running configuration to nonvolatile memory.

Step 1 Facing the rear of the router, place the power switch (on the power supply) in the OFF (O) position. Repeat this action if a second power supply is installed in the router.

Step 2 Observe the following items:

The green OK LED on the power supply turns off.

The fans stop operating.

The LEDs on the I/O controller turn off.

The LEDs on the port adapters turn off.

(14)

Rack-Mounting Cisco 7200 Series Routers

Disconnecting AC-Input Power

To disconnect AC-input power to Cisco 7200 series routers, complete the following steps:

Step 1 Unplug the input power cable from the power source.

Step 2 Push up on the cable-retention clip that secures the input power cable to the router’s power supply.

Step 3 Unplug the input power cable from the power supply. (See Figure 8.)

Figure 8 Disconnecting Power from a Cisco 7200 Series AC-Input Power Supply

Step 4 Repeat Step 1 through Step 3 if a second power supply is installed.

This completes the procedure for disconnecting AC-input power to Cisco 7200 series routers.

Disconnecting DC-Input Power

To disconnect DC-input power to Cisco 7200 series routers, complete the following steps:

Warning Before completing any of the following steps, and to prevent short-circuit or shock hazards, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.

Warning When installing the unit, the ground connection must always be made first and disconnected last.

Step 1 Turn off the power source and disconnect the –48V and +48V leads from the power source. You can leave the ground cable connected.

Step 2 Remove the cable tie that secures the –48V, +48V, and ground leads to the power supply faceplate. Save the cable tie.

H6744

NETWORK PROCESSING ENGINE-150

Internal fans AC-input power supply AC-input receptacle Power switch

(15)

Installing the Brackets on the Chassis

Note The cable tie that accompanied your DC-input power supply can be removed and replaced on the power supply without the use of a tool. If you secured the DC-input power supply leads to the power supply faceplate using a different type of cable tie, use a wire stripper to cut that cable tie from the power supply.

Step 3 Using a 3/16-inch flat-blade screwdriver, loosen the screw below the +48V lead receptacle and pull the lead from the connector (see Figure 9). Repeat this step for the -48V lead and the ground lead.

Note The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site. Typically, green or green/yellow is used for ground, black is used for +48V (return), and red or white is used for –48V. Make certain the lead color coding you choose for the DC-input power supply matches lead color coding used at the DC power source.

Figure 9 Disconnecting Power from a Cisco 7200 Series DC-Input Power Supply

Step 4 Repeat Step 1 through Step 3 if a second power supply is installed.

This completes the procedure for disconnecting DC-input power to Cisco 7200 series routers.

Installing the Brackets on the Chassis

This section explains how to install the rack-mount and cable-management brackets at the front and the rear of Cisco 7200 series routers. Before installing the chassis in the rack, you must install a rack-mount bracket on each side of the front or rear of the chassis. If you are rack-mounting the chassis from the front and you plan to use the cable-management brackets, you must install the cable-management brackets when you install the rack-mount brackets on the chassis.

H8619

NETWORK PROCESSING ENGINE-150

Internal fans

DC-input power supply DC-input receptacle

(16)

Rack-Mounting Cisco 7200 Series Routers

The parts and tools required for installing the rack-mount and cable-management brackets are listed in the “Tools and Parts Required” section on page 3.

Warning After attaching the brackets, and to avoid injury, we recommend that two people install the chassis in the rack. (One person should support the chassis in the rack while the second person installs the fasteners.)

Installing Brackets on the Front of the Chassis

To install the rack-mount and cable-management brackets on the chassis for a front rack-mount configuration, complete the following steps:

Step 1 Locate the threaded holes in the front sides of the chassis.

Step 2 If you want the front of the chassis protruding from the rack, align the first rack-mount bracket and the first cable-management bracket to the threaded holes in the right side of the chassis as shown in Figure 10.

Thread two M4 x 8-mm Phillips flathead screws through both brackets and into the side of the chassis. Use a number 2 Phillips screwdriver to tighten the screws. (See Figure 10.)

Figure 10 Installing the Rack-Mount Brackets on the Front of the Chassis so the Front of the Chassis Protrudes from the Rack—Cisco 7204 Shown

Step 3 If you want the front of the chassis recessed in the rack, align the first rack-mount bracket to the threaded holes in the right side of the chassis as shown in Figure 11.

Thread two M4 x 8-mm Phillips flathead screws through the bracket into the side of the chassis and use a number 2 Phillips screwdriver to tighten the screws. Then align the first cable-management bracket to the rack-mount bracket and thread two M4 x 8-mm Phillips flathead screws through the two brackets. Use a number 2 Phillips screwdriver to tighten the screws. (See Figure 11.)

ENABLED MIILINKRJ45

FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX H9159 Cisco 7200 SERIES MIIENRJ45ENRJ45LINK1O PWROK RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECT SLOT 0

SLOT 1 FE MII

Rack-mount bracket

Cable-management bracket

(17)

Installing the Brackets on the Chassis

Figure 11 Installing the Rack-Mount Brackets on the Front of the Chassis so the Front of the Chassis is Recessed in the Rack—Cisco 7204 Shown

Step 4 Repeat Step 1 through Step 3 for the other cable-management bracket (if required) and the rack-mount bracket.

This completes the procedure for installing the rack-mount and cable-management brackets on the chassis for a front rack-mount configuration.

Installing Brackets on the Rear of the Chassis

To install the rack-mount and cable-management brackets on the chassis for a rear rack-mount configuration, complete the following steps:

Step 1 Locate the threaded holes in the rear sides of the chassis.

Step 2 Align the first rack-mount bracket to the threaded holes in the right side of the chassis. If you want the front of the chassis protruding from the rack, align the rack-mount bracket to the chassis as shown in Figure 12. If you want the front of the chassis recessed in the rack, align the rack-mount bracket to the chassis as shown in Figure 13.

Figure 12 Installing the Rack-Mount Brackets on the Rear of the Chassis so the Front of the Chassis Protrudes from the Rack—Cisco 7204 Shown

MIIENRJ45ENRJ45LINK1O PWROK

RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECT SLOT 0

SLOT 1 FE MII

ENABLED MIILINKRJ45 FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX H9158 Cisco 7200 SERIES Rack-mount bracket Cable-management bracket

ENABLED MIILINKRJ45

FAST ETHERNET 0 2 4 1 3 EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX Cisco 7200 SERIES Rack-mount

(18)

Rack-Mounting Cisco 7200 Series Routers

Figure 13 Installing the Rack-Mount Brackets on the Rear of the Chassis so the Front of the Chassis is Recessed in the Rack—Cisco 7204 Shown

Step 3 Thread two M4 x 8-mm Phillips flathead screws through the rack-mount bracket and into the side of the chassis. Use a number 2 Phillips screwdriver to tighten the screws.

Step 4 Repeat Step 1 through Step 3 for the other rack-mount bracket.

Step 5 If you plan to include the cable-management brackets in your rear rack-mount

configuration, align the first rack-mount bracket to the threaded holes in the front sides of the chassis. (See Figure 12 and Figure 13.)

Step 6 Thread two M4 x 8-mm Phillips flathead screws through the bracket and into the chassis, and tighten the screws.

Step 7 Repeat Step 5 and Step 6 for the other cable-management brackets.

This completes the procedure for installing the rack-mount brackets and cable-management brackets on the chassis. Proceed to the section “Installing the Chassis in the Rack.

Warning To prevent injury, review the safety precautions in the section “Safety Guidelines” before installing the router in a rack.

Installing the Chassis in the Rack

After installing the brackets on the chassis, mount the router by securing the rack-mount brackets to two posts or mounting strips in the rack using the six slotted screws provided. Because the brackets support the weight of the entire chassis, be sure to use all six slotted screws to fasten the two rack-mount brackets to the rack posts. Figure 4, Figure 5, Figure 6, and Figure 7 show typical installations in a 19-inch 4-post rack and a telco-type equipment rack.

Warning To prevent the rack from tipping when installing the router in telco-type racks, ensure that the rack is bolted to the floor and, if necessary, anchored with appropriate fixtures.

We recommend that you allow at least 1 or 2 inches of vertical clearance between the router and any equipment directly above and below it.

Warning To maintain a low center of gravity, ensure that heavier equipment is installed near the bottom of the rack.

ENABLED MIILINKRJ45

FAST ETHERNET 0 0 2 4 1 3 EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX H9155 Cisco 7200 SERIES MIIENRJ45ENRJ45 LINK1O PWROK RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECT SLOT 0

SLOT 1 FE MII

Cable-management bracket

Rack-mount bracket

(19)

Reconnecting Input Power and Powering Up the Router

To install the chassis in the rack, complete the following steps:

Step 1 On the chassis, ensure that all captive screws on the network processing engine, the I/O controller, and each power supply are tightened and the port adapter levers are in the locked position.

Step 2 Make sure that your path to the rack is unobstructed. If the rack is on wheels, ensure that the brakes are engaged or that the rack is otherwise stabilized.

Warning To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules (such as power supplies, fans, or cards); these types of handles are not designed to support the weight of the unit. Lift the unit only by using handles that are an integral part of the chassis, or by grasping the chassis underneath its lower edge.

Warning Two people are required to lift the chassis. To prevent injury, keep your back straight and lift with your legs, not your back.

Step 3 Position the chassis so that the front end is closest to you; then lift the chassis and move it to the rack. To prevent injury, avoid sudden twists or moves.

Step 4 Slide the chassis into the rack, pushing it back until the brackets (installed at the front or rear of the chassis) meet the mounting strips or posts on both sides of the equipment rack.

Step 5 While keeping the brackets flush against the posts or mounting strips, position the router so that the holes in the brackets are aligned to those in the mounting strips.

Step 6 Insert all six 10-32 x 3/8-inch slotted screws (three on each side) through the brackets and into the mounting strip. (Use the top and bottom bracket holes, as shown in Figure 4, Figure 5, Figure 6, and Figure 7.) Using a 1/4-inch flat-blade screwdriver, tighten all the screws.

This completes the procedure for installing the chassis in the rack.

Reconnecting Input Power and Powering Up the Router

The following procedures explain how to reconnect AC-input and DC-input power to Cisco 7200 series routers, power up the router, and verify a successful system boot.

Warning Read the installation instructions before you connect the system to its power source.

Reconnecting AC-Input Power

To reconnect AC-input power to Cisco 7200 series routers, complete the following steps:

Step 1 At the rear of the router, check that the power switch on the power supply is in the OFF (O) position.

Step 2 Slide the cable-retention clip up, away from the AC receptacle, and plug in the power cable.

(20)

Rack-Mounting Cisco 7200 Series Routers

Figure 14 Connecting AC-Input Power to Cisco 7200 Series Routers

Step 4 Plug the AC power supply cable into the AC power source.

Note Each AC-input power supply operating at 120 VAC requires a minimum of 5A service. We recommend powering the Cisco 7200 series routers from a 15A receptacle at the power source.

Step 5 Repeat Step 1 through Step 4 if a second power supply is installed.

This completes the steps for reconnecting AC-input power to Cisco 7200 series routers.

H6848

AC power cable

Cable-retention clip

Hole for nylon cable tie Power switch

(21)

Reconnecting Input Power and Powering Up the Router

Reconnecting DC-Input Power

To reconnect DC-input power to Cisco 7200 series routers, complete the following steps:

Note The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site. Typically, green or green/yellow is used for ground, black is used for +48V (return), and red or white is used for –48V. Make certain the lead color coding you choose for the DC-input power supply matches lead color coding used at the DC power source.

Warning Before completing any of the following steps, and to prevent short-circuit or shock hazards, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.

Warning When installing the unit, the ground connection must always be made first and disconnected last.

Step 1 Ensure that the –48V and +48V leads are disconnected from the power source.

Step 2 If necessary, use a wire stripper to strip approximately 0.55 inch (14 mm) from the –48V, +48V, and ground leads. (See Figure 15.)

Figure 15 Stripping the DC-Input Leads

Step 3 At the rear of the router, check that the power switch on the power supply is in the OFF (O) position (see Figure 8).

Step 4 Insert the stripped end of the ground lead all the way into the ground lead receptacle on the DC-input power supply and tighten the receptacle screw using a 3/16-inch flat-blade screwdriver. (See Figure 16.)

0.55 in. (14 mm)

(22)

Rack-Mounting Cisco 7200 Series Routers

Figure 16 Connecting DC-Input Power

Step 5 Insert the stripped end of the +48V lead all the way into the +48V lead receptacle and tighten the receptacle screw using the same 3/16-inch flat-blade screwdriver. Repeat Step 5 for the -48V lead.

Note Make sure the entire stripped end of each lead is inserted all the way into its receptacle. If any exposed wire at the stripped end of a lead is visible after inserting the lead into its receptacle, remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and repeat Step 2 through Step 5.

Step 6 After tightening the receptacle screw for the ground, +48V, and –48V DC-input leads, use the cable tie you saved earlier in this procedure to secure the three leads to the power supply faceplate.

Note When securing the ground, +48V, and –48V DC-input leads to the power supply faceplate, leave a small service loop in the ground lead to ensure that it is the last lead to disconnect from the power supply if a great deal of strain is placed on all three leads. (See Figure 16.)

Step 7 Connect the ground, +48V, and –48V leads to the power source.

Note Each DC-input power supply operating at –48 VDC in North America requires a minimum of 13A service. Each DC-input power supply operating at –60 VDC in the European Community requires a minimum of 8A service.

This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that a listed and certified fuse or circuit breaker, 35A minimum 60 VDC, is used on all current-carrying conductors.

Step 8 Repeat Step 1 through Step 7 if a second power supply is installed.

H8622 DC power leads Cable tie Ground lead service loop Power switch

(23)

Reconnecting Input Power and Powering Up the Router

This completes the steps for reconnecting DC-input power to Cisco 7200 series routers.

Powering Up the Router

To power up Cisco 7200 series routers that have an installed AC-input or DC-input power supply, complete the following steps:

Caution Do not mix AC- and DC-input power supplies in the same router.

Step 1 Check for the following:

Each port adapter is inserted in its slot and its respective port adapter lever is in the locked position.

The network processing engine and the I/O controller are inserted in their respective slots, and their captive installation screws are tightened.

All network interface cables are connected to the port adapters.

A Flash memory card is installed in its PCMCIA slot (if present).

Each AC-input power cable is connected and secured with the cable-retention clip.

Each DC lead is connected and secured to the power supply faceplate with a cable tie.

Each DC lead is connected and secured to the power source.

For installed DC-input power supplies, ensure the tape (that you applied earlier) is removed from the circuit breaker switch handle, and power is restored by moving the circuit breaker handle to the ON position.

The console terminal is turned on.

Step 2 At the rear of the router, place the power switch on the power supply in the ON (|) position. Repeat this step if a second power supply is installed in the router. The green OK LED on the power supply turns on.

Step 3 Listen for the fans; you should immediately hear them operating.

Step 4 During the boot process, observe the system’s LEDs. The LEDs on most of the port adapters go on and off in irregular sequence. Some may go on, go out, and go on again for a short time. On the I/O controller, the IO power OK LED comes on immediately.

Step 5 Observe the initialization process. When the system boot is complete (a few seconds), the network processing engine begins to initialize the port adapters and the I/O controller. During this initialization, the LEDs on each port adapter behave differently (most flash on and off). The enabled LED on each port adapter goes on when initialization is completed, and the console screen displays a script and system banner similar to the following:

Cisco Internetwork Operating System Software

IOS (tm) 7200 Software (C7200-J-M), Version 11.1(9) [kpfjrgiu 100] Copyright (c) 1986-1996 by cisco Systems, Inc.

(24)

Installing Cable-Management Brackets on Routers in Workbench or Tabletop Configurations

Installing Cable-Management Brackets on Routers in Workbench or

Tabletop Configurations

This section explains how to install the cable-management brackets on Cisco 7200 series routers in tabletop or workbench installations. Instructions for installing the cable-management brackets on routers in rack-mount installations are in the “Rack-Mounting Cisco 7200 Series Routers” section on page 10. The list of tools and parts required to install the cable-management brackets are listed in the “Tools and Parts Required” section on page 3.

To install the cable-management brackets on Cisco 7200 series routers, complete the following steps:

Step 1 Ensure that input power to the router is turned off and disconnected. See the section “Powering Down the Router and Disconnecting Input Power” on page 13 of this document for instructions.

Step 2 Locate the threaded holes in the front sides of the chassis.

Step 3 Align the first cable-management bracket to the threaded holes in the right side of the chassis. (See Figure 12.)

Step 4 Thread two M4 x 8-mm Phillips flathead screws through the bracket and into the chassis. Use a number 2 Phillips screwdriver to tighten the screws.

Step 5 Repeat Step 1 through Step 4 for the other cable-management bracket on the left side of the chassis.

This completes the steps for installing the cable-management brackets on Cisco 7200 series routers in workbench or tabletop configurations.

Securing Port Adapter Interface Cables to Cable-Management

Brackets

The cable-management brackets are designed to relieve strain on port adapter interface cables that are installed on Cisco 7200 series port adapters. Eight removable tie wraps installed on the cable-management brackets secure port adapter interface cables to the brackets. We recommend that you use the tie wraps that shipped with the cable-management brackets. You can use standard tie wraps; however, you will have to cut and replace them with new tie wraps when you want to release or secure an interface cable to a bracket.

To secure port adapter interface cables to the cable-management brackets, complete the following steps:

Step 1 Ensure that input power to the router is turned off and disconnected.

Step 2 Select a tie wrap and release its locking mechanism.

Step 3 Carefully lace the interface cables from a port adapter installed in the chassis between the two ends of the unlocked tie wrap.

Note Be sure to leave a small service loop in the interface cable before securing it to the cable-management bracket.

Step 4 With the interface cables between the ends of the tie wrap and the interface cables’ service loop in place, tighten the cable tie down around the interface cables until they are secured against the cable-management bracket. (See Figure 17.)

(25)

Cisco Connection Online

Figure 17 Securing Interface Cables to the Cable-Management Brackets—Cisco 7204 Shown

Step 5 Repeat Step 1 through Step 4 for any other port adapter interface cables installed in the router.

Step 6 After securing port adapter interface cables to the cable-management brackets, reconnect input power, power up the router, and verify a successful system boot.

See the “Reconnecting Input Power and Powering Up the Router” section on page 19, to reconnect input power and power up Cisco 7200 series routers.

This completes the procedure for securing port adapter interface cables to cable-management brackets on Cisco 7200 series routers.

Cisco Connection Online

Cisco Connection Online (CCO) is Cisco Systems’ primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services. Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco’s customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CCO serves a wide variety of users through two interfaces that are updated and enhanced

simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CCO in the following ways:

WWW: http://www.cisco.com

WWW: http://www-europe.cisco.com

EN 0 1 2 3 4 5 6 7 SERIAL-EIA/TIA-232 0 2 4 1 3

ENABLED MIILINKRJ45

FAST ETHERNET 0 ETHERNET-10BFL EN RX 0 TX RX1 TX RX2 TX RX3 TX RX4 TX H9237 MIIENRJ45ENRJ45LINK1O PWROK RJ-45 CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA EJECTSLOT 0

SLOT 1 FE MII

(26)

Documentation CD-ROM

Modem: From North America, 408 526-8070; from Europe, 33 1 64 46 40 82. Use the following terminal settings: VT100 emulation; databits: 8; parity: none; stop bits: 1; and connection rates up to 28.8 kbps.

For a copy of CCO’s Frequently Asked Questions (FAQ), contact [email protected]. For additional information, contact [email protected].

Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco’s Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or [email protected]. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387,

408 526-7208, or [email protected].

Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com,

http://www-china.cisco.com, or http://www-europe.cisco.com.

If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

This document is to be used in conjunction with the documents listed in the “If You Need More Information” section.

AccessPath, Any to Any, AtmDirector, the CCIE logo, CD-PAC, Centri, the Cisco Capital logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, the Cisco Press logo, the Cisco Technologies logo, ClickStart, ControlStream, DAGAZ, Fast Step, FireRunner, IGX, IOS, JumpStart, Kernel Proxy, LoopRunner, MGX, Natural Network Viewer, NetRanger, NetRanger Director, NetRanger Sensor, NetSonar, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RouteStream, Secure Script, SMARTnet, SpeedRunner, Stratm, StreamView, The Cell, TrafficDirector, TransPath, ViewRunner, VirtualStream, VlanDirector, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, Enterprise/Solver, EtherChannel, FastHub, ForeSight, FragmentFree, IP/TV, IPX, LightStream, LightSwitch, MICA, Phase/IP, StrataSphere, StrataView Plus, and SwitchProbe are registered trademarks of Cisco Systems, Inc. in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. (9811R)

Copyright © 1996, 1997, 1998, Cisco Systems, Inc. All rights reserved. Printed in USA.

References

Related documents

Second line of Mahās ṣod ṣaśī mantra is formed thus; after these five bīja-s (in the first line), place pran ṣava, māyā bīja and śrī bīja and the second line appears

The prevalence of impair- ment found here suggests that assessment of visual memory should be included in long-term follow- up studies of TBI as approximately half the sample was

The EMCN Rehabilitation Group has been set up to establish a network wide Cancer Rehabilitation Strategy to address the recommendations in the NICE Guidance on Improving

Install new cable from existing OFTU in the customer comms room to the comms rack via ceiling space and cable duct. Install new proposed equipment in the

Rack accessories Optional available: rack mounting kits; cable management solutions; networking components, I/O switches, mounting kits, accessory kits, shelves,

Dit huidige onderzoek richt zich ook op de vraag of er een verband is tussen de effectiviteit van verandering en de betekenisgeving aan verandering door

• Phillips #1 screwdriver (for installing disk mounting handles on HDDs, rack mount brackets) • Tools to install the cameras and route power and video cables.. • Fasteners to

With a strong focus on cooling, power distribution, cable management and environmental monitoring, the NetShelter SX provides a reliable rack- mounting environment