S302D

2D Imaging

Barcode Scanner

(2)
(3)

Revision History

Changes to the original manual are listed below:

Version Date Description of Version

(4)

PROGRAMMING GUIDE

Important Notice

No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or fitness for any particular purpose. We are not liable for any errors contained herein nor for incidental or consequential damages in connection with furnishing, performance or use of this material. We shall be under no liability in respect of any defect arising from fair wear and tear, willful damage,

negligence, abnormal working conditions, failure to follow the instructions and warnings, or misuse or alteration or repair of the products without written approval. No part of this document may be reproduced, transmitted, stored in a retrieval system, transcribed, or translated into any human or computer or other language in any form or by any means electronic, mechanical, magnetic, optical, chemical, biological, manual or otherwise, except for brief passages which may be quoted for purposes of scholastic or literary review, without express written consent and authorization. We reserve the right to make changes in product design without reservation and without notification. The material in this guide is for information only and is subject to change without notice. All trademarks mentioned herein, registered or otherwise, are the properties of their various, ill, assorted owners.

General Handling Precautions

Do not dispose the scanner in fire.

Do not put the scanner directly in the sun or by any heat source. Do not use or store the scanner in a very humid place.

Do not drop the scanner or allow it to collide violently with other objects. Do not take the scanner apart without authorization

Guidance for Printing

This manual is in A5 size. Please double check your printer setting before printing it out. When the barcodes are to be printed out for programming, the use of a high-resolution laser printer is strongly suggested for the best scan result.

(5)

Table of Contents

Important Notice ... ii

General Handling Precautions ... ii

Guidance for Printing ... ii

Settings and Programming ... 1

Programming Options ... 1

Default Factory Device Settings... 1

Serial Programming Commands ... 2

Command Format ... 2 Trigger Commands ... 2 Responses ... 3 Interface Mode... 4 Interface Switch ... 4 Baud Rate ... 5

Word Format: Parity, Data bits, Stop bits ... 6

User Preferences ... 8

System Settings ... 8

Beeper-Good Read ... 9

Beeper Volume-Good Read ... 9

Beep During Good Decode ...10

LED Illumination ...10

LED-Good Read...11

Number Of Beep-Good Read ...11

Good Read Delay ...13

Same Code Delay...14

Scan Mode...15

Manual Mode Timeout ...15

Presentation Timeout ...15 Centering Windows ...16 Ship Image ... 17 No Read ... 17 Image Reverse ... 17 Data Redundant ...18 Data Editing ...19 Prefix / Suffix ...19

Prefix Set Up Flow ...19

Suffix Set Up Flow ... 20

Data Format ...21

Cap Locks ...22

(6)

PROGRAMMING GUIDE

Message Length ...23

Codabar ...24

Codabar Enable/Disable ...24

Codabar Stop/Start Characters ...24

Codabar Check Characters ... 25

Codabar Message Length ... 25

Code 39 ... 26

Code 39 Enable/Disable ... 26

Code 39 Full ASCII Conversion ... 26

Code 39 Append ... 27

Code 39 Check Characters ... 27

Code 39 Start/Stop Characters ...28

Code 32 Pharmaceutical ...28

Code 39 Message Length ...29

Trioptic ...29

Interleaved 2 of 5 ...30

Interleaved 2 of 5 Enable/Disable ...30

Interleaved 2 of 5 Check Characters ...31

Interleaved 2 of 5 Message Length ...31

NEC 25 ...32

NEC 25 Enable/Disable ...32

NEC 25 Check Characters ...33

Straight 2 of 5 Industrial ...34

Straight 2 of 5 Industrial Enable/Disable ...34

Straight 2 of 5 Message Length ...34

Matrix 2 of 5 ...35

Matrix 2 of 5 Enable/Disable ...35

Matrix 2 of 5 Message Length ...35

Code 11 ...36

Code 11 Enable/Disable ...36

Code 11 Check Characters ...36

Code 11 Message Length ... 37

Code 128 ...38

Code 128 Enable/Disable ...38

Code 128 Message Length ...38

Code 93 ...39

Code 93 Enable/Disable ...39

Code 93 Message Length ...39

MSI ...40

MSI Enable/Disable ...40

(7)

Telepen ...42

Telepen Enable/Disable ...42

Telepen Output ...42

Telepen Message Length ...43

UPC/EAN/JAN ...44

UPC-A Enable/Disable ...44

UPC-A Check Characters ...44

UPC-A Number System ... 45

UPC-A 2 Digit ... 45

UPC-A 5 Digit ...46

UPC-A Addenda Required ...46

UPC-A Addenda Separator ... 47

UPC-E0 ... 47

UPC-E1 ...48

UPC-E0 Expand ...48

UPC-E0 Check Digit ... 49

UPC-E0 Number System ... 49

UPC-E0 Addenda 2 Digit ... 50

UPC-E0 Addenda 5 Digit ... 50

UPC-E0 Addenda Required ... 51

UPC-E0 Addenda Separator ... 51

EAN/JAN-13 ... 52

EAN/JAN-13 Check Digit ... 52

EAN/JAN-13 2 Check Digit Addenda ... 53

EAN/JAN-13 5 Check Digit Addenda ... 53

EAN/JAN-13 Addenda Required ...54

EAN/JAN-13 Addenda Separator ...54

IBSN Translate ... 55

EAN-8 ... 55

EAN-8 Check Digit... 56

EAN-8 Check Digit Addenda ... 56

EAN-8 2 Check Digit Addenda ... 57

EAN-8 5 Check Digit Addenda ... 57

EAN-8 Addenda Required ...58

EAN-8 Addenda Separator...58

UPC-A/EAN-13 Extend Coupon Code ... 59

EAN.UCC Emulation ... 59

Postal Code...60

China Postal Code ...60

China Postal Code Message Length ...61

(8)

PROGRAMMING GUIDE

Korean Postal Code ... 62

Korean Postal Code Message Length ... 63

PostNet ... 63

PostNet Check Digit ...64

Planet Code ...64

Planet Code Check Digit ...65

British Post ...65

Japanese Post ...66

Canadian Post ...66

Kix Post ... 67

Australian Post ... 67

RSS (Reduced Space Symbology) ...68

RSS-14 ...68

RSS-Limited Code ... 69

RSS-Expanded Code ... 70

RSS-Expanded Code Message Length ... 70

2D Symbologies ... 71

PDF417 ... 71

PDF417 Message Length ... 71

Micro PDF417 ... 72

Micro PDF417 Message Length ... 72

TLC39 ... 73

Codablock F ... 74

Codablock F Message Length ... 74

Aztec ... 75

Aztec Message Length ... 75

Maxicode ... 76

Maxicode Message Length ... 76

Data Matrix ...77

Data Matrix Message Length ...77

QR Code ... 78

QR Code Message Length ... 78

Maintenance ... 79

Troubleshoot ... 79

Appendix A ...80

Standard Default Parameters ...80

Appendix B ...84

Code ID Table ...84

Appendix C ...85

Sample Barcodes ...85

(9)

Save ...91

Discard ...91

Appendix E ... 92

(10)
(11)

Settings and Programming

Scan selected barcodes in this manual to affect setup and programming of your handheld imaging barcode scanner. Decoding options and interface protocols can be tailored to a specific application. Setup parameters are stored in non-volatile memory in the scanner and are retained even when power is off. Setup parameters change only when you reset them.

You may need to hide adjacent code patches with your hand when scanning.

Programming Options

This section contains the following two divisions: 1. Default factory device settings.

2. Supported symbologies.

Default Factory Device Settings

User Preferences

Parameter Default

Baud Rate 115200 BPS

Word Format None, 8, 1

Illumination On

LED-Good Read On

Number of Beep-Good Read 1

Good Read Delay 200

Same Code Delay 500ms

Scan Mode Manual Trigger

Manual Mode 30000ms

Presentation 500ms

Centering Windows Off

Ship Image JPG/BMP

No Read Off

Image Reverse Off

(12)

Serial

Programming Commands

The serial programming commands can be used in place of the programming barcodes. Both the serial commands and the programming barcodes will program the engine. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual.

The device must be set to an RS-232 interface. The following commands could be sent via a PC COM PORT using terminal software

Command Format

Prefix:\x02M\x0D

Command:see the following commands list Command Format:Prefix+command Example:

Set Baud Rate to 300 Command:090D00.

Command Format:\x02M\x0D090D00.

Trigger Commands

Activate and Deactivate the scanner with serial trigger commands. Enter trigger mode, and send the following command

Activate:\x02T\x0D Deactivate:\x02U\x0D

The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been reached.

(13)

Responses

The device responds to serial commands with one of three responses ACK Indicates a good command

(14)

Interface Mode

Interface Switch

The S302D imaging barcode scanner supports USB virtual COM, USB-HID and RS232. The USB cable supports both USB virtual COM and USB-HID modes. Please install the virtual COM port driver before using USB Virtual COM.

 To use USB Virtual COM for the first time, scan the USB Virtual COM barcode below and then install the Virtual COM driver.

 To switch from USB Virtual Com to USB-HID mode after the virtual COM driver is installed, scan the USB HID barcode below.

 To switch from USB Virtual Com to USB-HID mode if the virtual COM driver is not installed:

1. Unplug USB cable from computer.

2. Press and hold the trigger while plugging USB cable to computer. 3. Scan the USB HID barcode below.

 To switch to RS232, change to RS232 interface cable and scan barcodes on next few pages to set up communication protocols.

USB HID (Default)

(15)

Baud Rate

Baud rate is the number of bits of data transmitted per second. Set the imager's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.

1200BPS 2400BPS 4800BPS 9600BPS 19200BPS 38400BPS

(16)

57600BPS

115200BPS (Default)

Word Format: Parity, Data bits, Stop bits

A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. Parity: checks character bit patterns for validity; Data bits: sets the word length; Stop bits: sets the stop bits.

None,7,1

None,7,2

None,8,1 (Default)

(17)

Even 7,1 Even 7,2 Even 8,1 Odd 7, 1 Odd 7, 2 Odd 8, 1

(18)

User Preferences

System Settings

Scan this barcode to return all parameters to the default values.

Set All Defaults

Scan this barcode to enable AUX Scanner.

Aux Scanner Enable

Scan this barcode to show scanner version.

Show Version

(19)

Beeper-Good Read

To enable or disable beeper, scan the following barcodes.

On

Off

Beeper Volume-Good Read

To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume barcode.

Off

Low Volume

(20)

Beep During Good Decode

Scan a barcode below to select the duration of the beep signal after a good decode.

Normal

Short

LED Illumination

To enable or disable LED illumination, scan the following barcodes.

On (Default)

(21)

LED-Good Read

To enable or disable LED indicator after a good read, scan the following barcodes.

On (Default)

Off

Number Of Beep-Good Read

Scan a barcode below to select the number of the beep signal to sound after a good decode.

1 (Default)

2

(22)

4

5

6

7

(23)

Good Read Delay

Scan a barcode below to set the minimum amount of time before the imager can read another barcode after a good read.

No Delay 200ms (Default) 500ms 2000ms *Specified

(24)

Same Code Delay

Scan a barcode below to set the minimum amount of time before the imager can read the same barcode a second time.

No Delay

500ms (Default)

(25)

Scan Mode

Scan a barcode below to set the imager to trigger manually or continue scanning until a barcode has been read.

Manual Trigger (Default)

Continue

Manual Mode Timeout

To a set timeout for the imager’s trigger when using Manual Trigger, scan the following “Timeout” barcode, then set the delay by scanning digits from the Appendix, then scan “Save” (Default: 30000).

Timeout (0-300,000ms)

Presentation Timeout

This option is used in Presentation mode to prevent multiple reads of a symbol left in the device’s field of view. To set the minimum amount of time before the imager can read the same barcode a second time, scan the following “Timeout” barcode then set the delay by scanning digits from the Appendix, then scan “Save” (Default: 500).

(26)

Centering Windows

To change the field of view of your imager, scan “On” to enable the feature, and then scan one of the following barcodes to change the top, bottom, left, or right of the centering window.

On

Off (Default)

Left of centering window 40%

Right of centering window 60%

Top of centering window 40%

(27)

Ship Image

To ship the image stored in the imager memory, scan the follow barcode.

JPG/BMP

No Read

Enable this function to transmit a No Read message when a code can not be read.

On

Off (Default)

Image Reverse

Enable this function to allow the imager to read barcodes that are inverted.

On

Off (Default)

(28)

Data Redundant

This function sets the imager to read the barcode multiple times before accepting data.

Data Redundant Check = Off (Default)

Data Redundant Check = 1

Data Redundant Check = 2

(29)

Data Editing

Prefix / Suffix

Prefix and Suffix are additional characters that can be sent before and after the scanned data.

Prefix

Suffix To set up Prefix/Suffix:

Prefix Set Up Flow

Ex. If we wish to add “3” as prefix for all barcode type, then follow procedure as below, Scanning [prefix] to enter setup. Then we select barcode by scanning code ID (ID table in the back) of all barcode which is [9] [9], then we scan [3] [3] as 3 of ASCII HEX. At the end, we scan [Save] to completed setup. So for full process, you scan [prefix] -> [9] [9] -> [3] [3] -> [Save].

Note: When adding a backslash (“\”or 5 C in Hex ID), please scan 5 C twice (5C5C): once to create the leading backslash and once to create the backlash itself.

(30)

Suffix Set Up Flow

Ex. If we wish to add “36” as suffix for all barcode type, then follow procedure as below, Scanning [suffix] to enter setup. Then we select barcode by scanning code ID of all barcode which is [9] [9], then we scan [3] [3] as 3 of ASCII HEX and [3] [6] as 6. Before we save, we scan command to setup terminator. If we wish to have Insert (01 from ASCII) & Enter (0A from ASCII) as terminator, we scan [0] [1] [0] [A]. To complete setup, we scan [Save]. So for full process, you scan [Suffix] -> [9] [9] -> [3] [3] -> [3] [6] -> [0] [1] -> [0] [A] -> [Save].

Note: For Suffix setup, terminator set up is required within suffix set up. If terminator is not set before save, terminator will automatically set to null.

(31)

Data Format

To change the output format, scan the following barcodes.

Data followed by <Enter> (Default)

No message after data

Data followed by <Enter> + new line

Data followed by new line

(32)

Cap Locks

To change the capital lock preferences, scan the following barcodes.

Cap Locks On

(33)

Symbologies

Introduction

This chapter describes symbology features and provides the programming barcodes for selecting these features.

The device is shipped with the settings shown in the Symbology Default Table. If the default values suit requirements, programming is not necessary.

There are two ways to change a parameter value:

 Scan the appropriate barcodes in this guide. These new values replace the standard default values in memory.

 For serial hosts, send a “parameter send” command from the host system. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual. Note: Most computer monitors allow scanning the barcodes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the barcode can be seen clearly and bars and/or spaces are not merging.

Message Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.

To set the length of a barcode symbology:

1. Scan the “Minimum” or “Maximum” barcode to enter program mode. 2. Scan the digit(s) from the ASCII table in Appendix.

3. Scan “Save” to save the change.

Note: When setting lengths for different barcode types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero.

(34)

Codabar

Codabar Enable/Disable

To set Codabar to its default settings, scan Default; to enable or disable Codabar, scan On or Off.

Default

On (Default)

Off

Codabar Stop/Start Characters

Stop/Start Characters set the leading and trailing ends of the barcode.

Don’t Transmit (Default)

(35)

Codabar Check Characters

Scan a barcode below to set the Codabar check character preferences.

No Check Character (Default)

Validate But Don’t Transmit

Validate And Transmit

Codabar Message Length

Please see Message Length on setting the message length.

Maximum (Default: 60)

(36)

Code 39

Code 39 Enable/Disable

To set Code 39 to its default settings, scan Default; to enable or disable Code 39, scan On or Off.

Default

On (Default)

Off

Code 39 Full ASCII Conversion

Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. Scan the appropriate barcode below to enable or disable it.

Off (Default)

(37)

Code 39 Append

To set the imager to append Code 39 data before transmitting to the host, scan the appropriate barcode below.

On

Off (Default)

Code 39 Check Characters

Scan a barcode below to set the Code 39 check character preferences.

No Check Character (Default)

Validate But Don’t Transmit

(38)

Code 39 Start/Stop Characters

Start/Stop Characters set the leading and trailing ends of the barcode.

Transmit

Don’t Transmit (Default)

Code 32 Pharmaceutical

To enable/ disable Code 39 Pharmaceutical, scan the appropriate barcode below.

On

Off (Default)

(39)

Code 39 Message Length

Please see Message Length on setting the message length.

Minimum (Default: 0)

Maximum (Default: 48)

Trioptic

To enable/ disable Trioptic code, scan the appropriate barcode below.

On

Off (Default)

(40)

Interleaved 2 of 5

Interleaved 2 of 5 Enable/Disable

To set Interleaved 2 of 5 to its default settings, scan Default; to enable or disable Interleaved 2 of 5, scan On or Off.

Default

On (Default)

(41)

Interleaved 2 of 5 Check Characters

Scan a barcode below to set the Interleaved 2 of 5 check character preferences.

No Check Character (Default)

Validate But Don’t Transmit

Validate And Transmit

Interleaved 2 of 5 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 80)

(42)

NEC 25

NEC 25 Enable/Disable

To set NEC 25 to its default settings, scan Default; to enable or disable NEC 25, scan On or Off.

Default

On (Default)

(43)

NEC 25 Check Characters

Scan a barcode below to set the NEC 25 check character preferences.

No Check Character (Default)

Validate But Don’t Transmit

(44)

Straight 2 of 5 Industrial

Straight 2 of 5 Industrial Enable/Disable

To set Straight 2 of 5 Industrial to its default settings, scan Default; to enable or disable Straight 2 of 5 Industrial, scan On or Off.

Default

On

Off (Default)

Straight 2 of 5 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 48)

(45)

Matrix 2 of 5

Matrix 2 of 5 Enable/Disable

To set Matrix 2 of 5 to its default settings, scan Default; to enable or disable Matrix 2 of 5, scan On or Off.

Default

On

Off (Default)

Matrix 2 of 5 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 80)

(46)

Code 11

Code 11 Enable/Disable

To set Code 11 to its default settings, scan Default; to enable or disable Code 11, scan On or Off.

Default

On

Off (Default)

Code 11 Check Characters

Scan a barcode below to set the Code 11 check character preferences.

2 Check Digit (Default)

(47)

Code 11 Message Length

Please see Message Length on setting the message length.

Minimum (Default: 4)

Maximum (Default: 80)

(48)

Code 128

Code 128 Enable/Disable

To set Code 128 to its default settings, scan Default; to enable or disable Code 128, scan On or Off.

Default

On (Default)

Off

Code 128 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 80)

(49)

Code 93

Code 93 Enable/Disable

To set Code 93 to its default settings, scan Default; to enable or disable Code 93, scan On or Off.

Default

On (Default)

Off

Code 93 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 80)

(50)

MSI

MSI Enable/Disable

To set MSI to its default settings, scan Default; to enable or disable MSI, scan On or Off.

Default

On

Off (Default)

MSI Check Characters

Scan a barcode below to set the MSI check character preferences.

Validate Type 10, Transmit

(51)

MSI Message Length

Please see Message Length on setting the message length.

Minimum (Default: 4)

Maximum (Default: 48)

(52)

Telepen

Telepen Enable/Disable

To set Telepen to its default settings, scan Default; to enable or disable Telepen, scan On or Off. Default On Off (Default)

Telepen Output

Scan a barcode below to set the Telepen Output preferences.

Original Output

(53)

Telepen Message Length

Please see Message Length on setting the message length.

Minimum (Default: 1)

Maximum (Default: 60)

(54)

UPC/EAN/JAN

UPC-A Enable/Disable

To set UPC-A to its default settings, scan Default; to enable or disable UPC-A, scan On or Off.

Default

On (Default)

Off

UPC-A Check Characters

Scan a barcode below to set the UPC-A check character preferences.

Off

(55)

UPC-A Number System

Scan a barcode below to set the UPC-A Number System preferences.

On (Default)

Off

UPC-A 2 Digit

Scan a barcode below to set the UPC-A 2 Digit preferences.

On

Off (Default)

(56)

UPC-A 5 Digit

Scan a barcode below to set the UPC-A 5 Digit preferences.

On

Off (Default)

UPC-A Addenda Required

Scan a barcode below to set the UPC-A Addenda Required preferences.

On

Off (Default)

(57)

UPC-A Addenda Separator

Scan a barcode below to set the UPC-A Addenda Separator preferences.

On (Default)

Off

UPC-E0

To set UPC-E0 to its default settings, scan Default; to enable or disable UPC-E0, scan On or Off.

Default

On (Default)

(58)

UPC-E1

Scan a barcode below to set the UPC-E1 preferences.

On

Off (Default)

UPC-E0 Expand

Scan a barcode below to set the UPC-E0 Expand preferences.

On

Off (Default)

(59)

UPC-E0 Check Digit

Scan a barcode below to set the UPC-E0 Check Digit preferences.

On (Default)

Off

UPC-E0 Number System

Scan a barcode below to set the UPC-E0 Number System preferences.

On (Default)

(60)

UPC-E0 Addenda 2 Digit

Scan a barcode below to set the UPC-E0 Addenda 2 Digit preferences.

On

Off (Default)

UPC-E0 Addenda 5 Digit

Scan a barcode below to set the UPC-E0 Addenda 5 Digit preferences.

On

Off (Default)

(61)

UPC-E0 Addenda Required

Scan a barcode below to set the UPC-A Addenda Required preferences.

Not Required (Default)

Required

UPC-E0 Addenda Separator

Scan a barcode below to set the UPC-A Addenda Separator preferences.

On (Default)

(62)

EAN/JAN-13

To set EAN/JAN-13 to its default settings, scan Default; to enable or disable EAN/JAN-13, scan On or Off.

Default

On (Default)

Off

EAN/JAN-13 Check Digit

Scan a barcode below to set the EAN/JAN-13 Check Digit preferences.

Off

On (Default)

(63)

EAN/JAN-13 2 Check Digit Addenda

Scan a barcode below to set the EAN/JAN-13 2 Check Digit Addenda preferences.

On

Off (Default)

EAN/JAN-13 5 Check Digit Addenda

Scan a barcode below to set the EAN/JAN-13 5 Check Digit Addenda preferences.

On

Off (Default)

(64)

EAN/JAN-13 Addenda Required

Scan a barcode below to set the UPC-A Addenda Required preferences.

Not Required (Default)

Required

EAN/JAN-13 Addenda Separator

Scan a barcode below to set the UPC-A Addenda Separator preferences.

On (Default)

(65)

IBSN Translate

Scan a barcode below to set the IBSN Translate preferences.

On

Off (Default)

EAN-8

To set EAN -8 to its default settings, scan Default; to enable or disable EAN-8, scan On or Off.

Default

On (Default)

(66)

EAN-8 Check Digit

Scan a barcode below to set the EAN-8 Check Digit preferences.

On (Default)

Off

EAN-8 Check Digit Addenda

Scan a barcode below to set the EAN-8 Check Digit Addenda preferences.

On

Off (Default)

(67)

EAN-8 2 Check Digit Addenda

Scan a barcode below to set the EAN-8 2Check Digit Addenda preferences.

On

Off (Default)

EAN-8 5 Check Digit Addenda

Scan a barcode below to set the EAN-8 5 Check Digit Addenda preferences.

On

Off (Default)

(68)

EAN-8 Addenda Required

Scan a barcode below to set the EAN-8 Addenda Required preferences.

Not Required (Default)

Required

EAN-8 Addenda Separator

Scan a barcode below to set the EAN-8 Addenda Separator preferences.

On (Default)

(69)

UPC-A/EAN-13 Extend Coupon Code

Scan a barcode below to set the UPC-A/EAN-13 Extend Coupon Code preferences.

On

Off (Default)

EAN.UCC Emulation

Scan a barcode below to set the EAN.UCC Emulation preferences.

Off (Default)

EAN.UCC-128 Emulation

(70)

Postal Code

Note: For best performance when reading a postal code, please enable only one postal symbology and disable the rest.

To enable or disable a postal code, please scan the following barcode first to enter programming mode, then scan the On or Off barcode for your postal code.

Postal Code

China Postal Code

To set China Postal Code to its default settings, scan Default; to enable or disable China Postal Code, scan On or Off.

Default

On

Off (Default)

(71)

China Postal Code Message Length

Please see Message Length on setting the message length.

Minimum (Default: 4)

Maximum (Default: 80)

Han Xin Code

To set Han Xin Code to its default settings, scan Default; to enable or disable Han Xin Code, scan On or Off.

Default

On

(72)

Han Xin Code Message Length

Please see Message Length on setting the message length.

Minimum (Default: 1)

Maximum (Default: 7873)

Korean Postal Code

To set Korean Postal Code to its default settings, scan Default; to enable or disable Korean Postal Code, scan On or Off.

Default

On

(73)

Korean Postal Code Message Length

Please see Message Length on setting the message length.

Minimum (Default: 4)

Maximum (Default: 48)

PostNet

Scan a barcode below to enable or disable PostNet.

On

Off (Default)

(74)

PostNet Check Digit

Scan a barcode below to set the PostNet Check Digit preferences.

Not Transmit (Default)

Transmit

Planet Code

Scan a barcode below to enable or disable Planet Code.

On

Off (Default)

(75)

Planet Code Check Digit

Scan a barcode below to set the Planet Code Check Digit preferences.

Don’t Transmit (Default)

Transmit

British Post

Scan a barcode below to enable or disable British Post code.

On

Off (Default)

(76)

Japanese Post

Scan a barcode below to enable or disable Japanese Post code.

On

Off (Default)

Canadian Post

Scan a barcode below to enable or disable Canadian Post code.

On

Off (Default)

(77)

Kix Post

Scan a barcode below to enable or disable Kix Post code.

On

Off (Default)

Australian Post

Scan a barcode below to enable or disable Australian Post code.

On

Off (Default)

(78)

RSS (Reduced Space Symbology)

The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and

expanded versions have stacked variants. Scan the appropriate barcode below to enable or disable each variant of RSS.

RSS-14

To set RSS-14 to its default settings, scan Default; to enable or disable RSS-14, scan On or Off.

Default

On (Default)

(79)

RSS-Limited Code

To set Limited Code to its default settings, scan Default; to enable or disable RSS-Limited, scan On or Off.

Default

On (Default)

(80)

RSS-Expanded Code

To set Expanded Code to its default settings, scan Default; to enable or disable RSS-Expanded, scan On or Off.

Default

On (Default)

Off

RSS-Expanded Code Message Length

Please see Message Length on setting the message length.

Maximum

(81)

2D Symbologies

PDF417

To set PDF417 to its default settings, scan Default; to enable or disable PDF417, scan On or Off. Default On (Default) Off

PDF417 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 2750)

(82)

Micro PDF417

To set Micro PDF417 to its default settings, scan Default; to enable or disable Micro PDF417, scan On or Off.

Default

On

Off (Default)

Micro PDF417 Message Length

Please see Message Length on setting the message length.

Maximum (Default: 366)

(83)

TLC39

Scan a barcode below to enable or disable TLC39.

On

Off (Default)

(84)

Codablock F

To set Codablock F to its default settings, scan Default; to enable or disable Codablock F, scan On or Off.

Default

On

Off (Default)

Codablock F Message Length

Please see Message Length on setting the message length.

Maximum (Default: 2048)

(85)

Aztec

To set Aztec to its default settings, scan Default; to enable or disable Aztec, scan On or Off.

Default

On (Default)

Off

Aztec Message Length

Please see Message Length on setting the message length.

Maximum (Default: 3832)

(86)

Maxicode

To set Maxicode to its default settings, scan Default; to enable or disable Maxicode, scan On or Off.

Default

On

Off

Maxicode Message Length

Please see Message Length on setting the message length.

Maximum (Default: 150)

Minimum (Default: 1)

(87)

Data Matrix

To set Data Matrix to its default settings, scan Default; to enable or disable Data Matrix, scan On or Off.

Default

On (Default)

Off

Data Matrix Message Length

Please see Message Length on setting the message length.

Maximum (Default: 3116)

(88)

QR Code

To set QR Code to its default settings, scan Default; to enable or disable QR Code, scan On or Off.

Default

On (Default)

Off

QR Code Message Length

Please see Message Length on setting the message length.

Maximum (Default: 7089)

Minimum (Default: 1)

(89)

Maintenance

Cleaning the scan window is the only maintenance required. A dirty window may affect scanning accuracy.

Never use any abrasive material or solvents on the window. Do not spray water or other cleaning liquids directly onto the window.

Remove dirt by wiping gently with a damp cloth or tissue moistened with water and/or ammonia.

Troubleshoot

Follow the table below for ways to switch interface when the cable is missing. USB mode to RS232 mode USB mode to USB Virtual COM RS232 to USB mode

Default Multi-interfaces Mode already cover both USB & RS-232 interfaces

No power, (hold the trigger, re-plug USB cable, power on to scan mode switch barcode commands and working properly)

Default Multi-interfaces Mode already cover both USB & RS-232 interfaces

(90)

Appendix A

Standard Default Parameters

Symbology Default

Codabar Enable

Code 39 Enable

Code 39 Full ASCII Disable

Code 39 Append Disable

Code 39 Check Char No check char Code 39 start/stop char Don’t transmit Code 32 Pharmaceutical Disable Code 39 Message Length 0~48

Interleaved 2 of 5 Enable

Interleaved 2 of 5 Check Char No check char Interleaved 2 of 5 Message

Length 4~80

NEC 25 Enable

NEC 25 Check Char

No check char Straight 2 of 5 Industrial Disable Straight 2 of 5 Industrial

Message 4~48

Straight 2 of 5 Industrial IATA Disable Straight 2 of 5 Industrial IATA

Message Length 4~48

Matrix 2 of 5 Disable

Matrix 2 of 5 Message Length 4~80

Code 11 Disable

Code 11 Message Length 4~80

Code 11 Check Char 2 check digits

(91)

Code 128 Message Length 0~80

Code 93 Enable

Code 93 Message Length 0~80

MSI Disable

MSI Message Length

4~48

MSI Check Char Validate Type 10,

Don’t Transmit

Telepen Disable

Telepen Output AIM output

Telepen Message Length 1~60

UPC-A Enable

UPC-A Check char Enable

UPC-A Number System Enable

UPC-A 2 digit Disable

UPC-A 5 digit Disable

UPC-A Addenda Required Disable UPC-A Addenda Separator Enable

UPC-E0 Enable

UPC-E1 Disable

UPC-E0 Expand Disable

UPC-E0 Check digit Enable

UPC-E0 Number System Enable UPC-E0 Addenda 2 digit Disable UPC-E0 Addenda 5 digit Disable UPC-E0 Addenda Required Not required UPC-E0 Addenda Separator Enable

EAN/JAN-13 Enable

(92)

EAN/JAN-13 2 Check Digit

Addenda Disable

EAN/JAN-13 5 Check Digit

Addenda Disable

EAN/JAN-13 Addenda

Required Not required

EAN/JAN-13 Addenda

Separator Enable

IBSN Translate Disable

EAN-8 Enable

EAN-8 Check Digit Enable

EAN-8 2 Check Digit Addenda Disable EAN-8 5 Check Digit Addenda Disable EAN-8 Addenda Required Not required EAN-8 Addenda Separator Enable UPC-A/EAN-13 Extend Coupon

Code Disable

EAN.UCC Emulation Disable

China Postal Code Disable

China Postal Code Message

Length 4~80

RSS-14 Enable

RSS-Limited Code Enable

RSS-Expanded Code Enable

RSS-Expanded Code Message

Length 4~74

Trioptic Code Disable

PDF417 Enable

PDF417 Message Length 1~2750

Micro PDF417 Disable

Micro PDF417 Message Length 1~366

(93)

Codablock F Disable Codablock F Message Length 1~2048

Aztec Enable

Aztec Message Length 1~3832

Maxicode Enable

Maxicode Message Length 1~150

Data Matrix Enable

Data Matrix Message Length 1~3116

QR Enable

QR Message Length 1~7089

Han Xin Code Disable

Han Xin CodeMessage Length 1~7873

Korean Postal Code Disable

Korean Postal Code Message

Length 4~48

PostNet Disable

PostNet Check Digit Don’t transmit

Planet Code Disable

Planet Code Check Digit Don’t transmit

British Post Disable

Japanese Post Disable

Canadian Post Disable

Kix Post Disable

(94)

Appendix B

Code ID Table

Symbology Code ID Code ID in HEX

Code 128 j 6A GS1-128(UCC/EAN-128) j 6A AIM-128 f 66 EAN-8 d 64 EAN-13 d 64 ISSN n 6E ISBN B 42 UPC-E c 63 UPC-A c 63 Interleaved 2 of 5 e 65 ITF-6 e 65 ITF-14 e 65 Matrix 2 of 5 v 76 Industrial 2 of 5 D 44 Standard 2 of 5 s 73 Code 39 b 62 Codabar a 61 Code 93 i 69 Code 11 H 48 GS1 Databar R 52 PDF417 r 72 QR Code Q 51 Data Matrix u 75 All 99

(95)

Appendix C

Sample Barcodes

Canada Post 4-State

01,K1A0B1,7010,

Japan Post 4-State

80342716666

US POSTNET

8034271888

Australian Post

8034271999

Dutch Post - Royal TPG Post KIX 4-State

1231FZ13XHS

USPS PLANET Barcode

4012345235636

British Royal Mail 4-State BPO

(96)

Infomail Mail 4-State

Sweden Post 4-State

(97)

USPS 4-state (Intelligent Mail)

Barcode ID...82

Service Type ID....152

Mailer ID...568794

Serial Number...748970563

ZIP Code...12789600178

Barcode ID...00

Service Type ID....311

Mailer ID...000479

Serial Number...612518080

ZIP Code...20724170703

Barcode ID...20

Service Type ID....301

Mailer ID...901212001

Serial Number...311323

(98)

Appendix D

Numeric Barcodes

For parameters requiring specific numeric values, scan the appropriately numbered barcode(s).

0

1

2

(99)

5

6

7

8

(100)

B C D E F

(101)

Save

To save the setting, scan the barcode below.

Save

Discard

To correct an error or change a selection, scan the barcode below.

(102)

Appendix E

Full ASCII Table

ASCII Hexacode ASCII Hexacode

Full ASCII ---NUL 00 Full ASCII ---SI

Function key---“Shift” 0F Full ASCII ---SOH

Function key---“Ins” 01

Full ASCII ---DLE

Function key---“5(num)” 10 Full ASCII ---STX

Function key---“Del” 02

Full ASCII ---DC1

Function key---“F1” 11

Full ASCII ---ETX

Function key---“Home” 03

Full ASCII ---DC2

Function key---“F2” 12

Full ASCII ---EOT

Function key---“End” 04

Full ASCII ---DC3

Function key---“F3” 13

Full ASCII ---ENQ

Function key---“Up arrow” 05

Full ASCII ---DC4

Function key---“F4” 14

Full ASCII ---ACK

Function key---“Down arrow”

06 Full ASCII ---NAK Function key---“F5”

15 Full ASCII ---BEL

Function key---“Left arrow”

07 Full ASCII ---SYN Function key---“F6”

16 Full ASCII ---BS

Function key---“Backspace”

08 Full ASCII ---ETB Function key---“F7”

17 Full ASCII ---HT

Function key---“TAB”

09 Full ASCII ---CAN Function key---“F8”

18 Full ASCII ---LF

Function key---“Enter (alpha numeric)”

0A Full ASCII ---EN Function key---“F9”

19

Full ASCII ---VT

Function key---“right arrow”

0B Full ASCII ---SUB Function key---“F10”

1A Full ASCII ---FF

Function key---“PgUp”

0C Full ASCII ---ESC Function key---“F11” 1B Full ASCII ---CR Function key---“Enetr(num.)” 0D Full ASCII ---FS Function key---“F12” 1C Full ASCII ---SO

Function key---“PgDn”

0E Full ASCII ---GS Function key---“ESC”

(103)

Full ASCII ---RS

Function key---“CTL(L)”

1E Full ASCII ---- 2D

Full ASCII ---US

Function key---“ALT(L)”

1F Full ASCII ---. 2E

Full ASCII ---SP 20 Full ASCII ---/ 2F

Full ASCII ---! 21 Full ASCII ---0 30

Full ASCII ---“ 22 Full ASCII ---1 31

Full ASCII ---# 23 Full ASCII ---2 32

Full ASCII ---$ 24 Full ASCII ---3 33

Full ASCII ---% 25 Full ASCII ---4 34

Full ASCII ---& 26 Full ASCII ---5 35

Full ASCII ---‘ 27 Full ASCII ---6 36

Full ASCII --- ( 28 Full ASCII ---7 37

Full ASCII ---) 29 Full ASCII ---8 38

Full ASCII ---* 2A Full ASCII ---9 39

Full ASCII ---+ 2B Full ASCII ---: 3A

Full ASCII ---, 2C Full ASCII ---; 3B

Full ASCII ---< 3C Full ASCII ---K 4B

Full ASCII ---= 3D Full ASCII ---L 4C

Full ASCII ---> 3E Full ASCII ---M 4D

(104)

Full ASCII ---@ 40 Full ASCII ---O 4F

Full ASCII ---A 41 Full ASCII ---P 50

Full ASCII ---B 42 Full ASCII ---Q 51

Full ASCII ---C 43 Full ASCII ---R 52

Full ASCII ---D 44 Full ASCII ---S 53

Full ASCII ---E 45 Full ASCII ---T 54

Full ASCII ---F 46 Full ASCII ---U 55

Full ASCII ---G 47 Full ASCII ---V 56

Full ASCII ---H 48 Full ASCII ---W 57

Full ASCII ---I 49 Full ASCII ---X 58

Full ASCII ---J 4A Full ASCII ---Y 59

Full ASCII ---Z 5A Full ASCII ---i 69

Full ASCII ---[ 5B Full ASCII ---j 6A

Full ASCII ---\ 5C Full ASCII ---k 6B

Full ASCII ---] 5D Full ASCII ---l 6C

Full ASCII ---^ 5E Full ASCII ---m 6D

Full ASCII ---_ 5F Full ASCII ---n 6E

Full ASCII ---` 60 Full ASCII ---o 6F

(105)

Full ASCII ---b 62 Full ASCII ---q 71

Full ASCII ---c 63 Full ASCII ---r 72

Full ASCII ---d 64 Full ASCII ---s 73

Full ASCII ---e 65 Full ASCII ---t 74

Full ASCII ---f 66 Full ASCII ---u 75

Full ASCII ---g 67 Full ASCII ---v 76

Full ASCII ---h 68 Full ASCII ---w 77

Full ASCII ---x 78 Full ASCII ---| 7C

Full ASCII ---y 79 Full ASCII ---} 7D

Full ASCII ---z 7A Full ASCII ---~ 7E

References

Related documents

Scan Enter Group 9-4 Label Scan User Define Label--&gt; Scan Six Digit Labels in Table Hex (Only 3 sets of length can be defined) Scan Confirm Label in Table Hex --&gt; Scan

If you make a mistake in attempting to update a scanner setting, such as accidentally scanning the wrong barcode or forgetting a step, scan the [Reset] barcode below to start

Note: Read the &#34;Disable Industrial 25&#34; barcode will make the scanner not able to read the Industrial 25 barcode. Thus, if the scanner cannot read the Industrial 25

WebDT Mobile Tablet Barcode Scanner Operation Guide Mobile POS Tablet..

Please refer Programming Guide and be sure to select the correct interface selection and ensure that the scanner is programmed to read the type of barcode you are scanning.

To re-connect scanner with the Command Center scan the TRMUSB130 programming barcode to set the base/scanner to USB serial mode (“Xenon™ 1900/1902 User’s Guide” p.. 7-47)

The default serial interface parameter is as below shown, when it is inconsistent with the host, it can be modified by Read Setting Barcode.. Parameter

24 hours/day Compressed Air, 100 psi (A) Radioisotopes Industrial Hot Water (IHW) Carcinogens/Regulated Industrial Cold Water (ICW) Chemical Waste Storage. MECHANICAL Potable Hot