S302D
2D Imaging
Barcode Scanner
Revision History
Changes to the original manual are listed below:
Version Date Description of Version
PROGRAMMING GUIDE
Important Notice
No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or fitness for any particular purpose. We are not liable for any errors contained herein nor for incidental or consequential damages in connection with furnishing, performance or use of this material. We shall be under no liability in respect of any defect arising from fair wear and tear, willful damage,
negligence, abnormal working conditions, failure to follow the instructions and warnings, or misuse or alteration or repair of the products without written approval. No part of this document may be reproduced, transmitted, stored in a retrieval system, transcribed, or translated into any human or computer or other language in any form or by any means electronic, mechanical, magnetic, optical, chemical, biological, manual or otherwise, except for brief passages which may be quoted for purposes of scholastic or literary review, without express written consent and authorization. We reserve the right to make changes in product design without reservation and without notification. The material in this guide is for information only and is subject to change without notice. All trademarks mentioned herein, registered or otherwise, are the properties of their various, ill, assorted owners.
General Handling Precautions
Do not dispose the scanner in fire.
Do not put the scanner directly in the sun or by any heat source. Do not use or store the scanner in a very humid place.
Do not drop the scanner or allow it to collide violently with other objects. Do not take the scanner apart without authorization
Guidance for Printing
This manual is in A5 size. Please double check your printer setting before printing it out. When the barcodes are to be printed out for programming, the use of a high-resolution laser printer is strongly suggested for the best scan result.
Table of Contents
Important Notice ... ii
General Handling Precautions ... ii
Guidance for Printing ... ii
Settings and Programming ... 1
Programming Options ... 1
Default Factory Device Settings... 1
Serial Programming Commands ... 2
Command Format ... 2 Trigger Commands ... 2 Responses ... 3 Interface Mode... 4 Interface Switch ... 4 Baud Rate ... 5
Word Format: Parity, Data bits, Stop bits ... 6
User Preferences ... 8
System Settings ... 8
Beeper-Good Read ... 9
Beeper Volume-Good Read ... 9
Beep During Good Decode ...10
LED Illumination ...10
LED-Good Read...11
Number Of Beep-Good Read ...11
Good Read Delay ...13
Same Code Delay...14
Scan Mode...15
Manual Mode Timeout ...15
Presentation Timeout ...15 Centering Windows ...16 Ship Image ... 17 No Read ... 17 Image Reverse ... 17 Data Redundant ...18 Data Editing ...19 Prefix / Suffix ...19
Prefix Set Up Flow ...19
Suffix Set Up Flow ... 20
Data Format ...21
Cap Locks ...22
PROGRAMMING GUIDE
Message Length ...23
Codabar ...24
Codabar Enable/Disable ...24
Codabar Stop/Start Characters ...24
Codabar Check Characters ... 25
Codabar Message Length ... 25
Code 39 ... 26
Code 39 Enable/Disable ... 26
Code 39 Full ASCII Conversion ... 26
Code 39 Append ... 27
Code 39 Check Characters ... 27
Code 39 Start/Stop Characters ...28
Code 32 Pharmaceutical ...28
Code 39 Message Length ...29
Trioptic ...29
Interleaved 2 of 5 ...30
Interleaved 2 of 5 Enable/Disable ...30
Interleaved 2 of 5 Check Characters ...31
Interleaved 2 of 5 Message Length ...31
NEC 25 ...32
NEC 25 Enable/Disable ...32
NEC 25 Check Characters ...33
Straight 2 of 5 Industrial ...34
Straight 2 of 5 Industrial Enable/Disable ...34
Straight 2 of 5 Message Length ...34
Matrix 2 of 5 ...35
Matrix 2 of 5 Enable/Disable ...35
Matrix 2 of 5 Message Length ...35
Code 11 ...36
Code 11 Enable/Disable ...36
Code 11 Check Characters ...36
Code 11 Message Length ... 37
Code 128 ...38
Code 128 Enable/Disable ...38
Code 128 Message Length ...38
Code 93 ...39
Code 93 Enable/Disable ...39
Code 93 Message Length ...39
MSI ...40
MSI Enable/Disable ...40
Telepen ...42
Telepen Enable/Disable ...42
Telepen Output ...42
Telepen Message Length ...43
UPC/EAN/JAN ...44
UPC-A Enable/Disable ...44
UPC-A Check Characters ...44
UPC-A Number System ... 45
UPC-A 2 Digit ... 45
UPC-A 5 Digit ...46
UPC-A Addenda Required ...46
UPC-A Addenda Separator ... 47
UPC-E0 ... 47
UPC-E1 ...48
UPC-E0 Expand ...48
UPC-E0 Check Digit ... 49
UPC-E0 Number System ... 49
UPC-E0 Addenda 2 Digit ... 50
UPC-E0 Addenda 5 Digit ... 50
UPC-E0 Addenda Required ... 51
UPC-E0 Addenda Separator ... 51
EAN/JAN-13 ... 52
EAN/JAN-13 Check Digit ... 52
EAN/JAN-13 2 Check Digit Addenda ... 53
EAN/JAN-13 5 Check Digit Addenda ... 53
EAN/JAN-13 Addenda Required ...54
EAN/JAN-13 Addenda Separator ...54
IBSN Translate ... 55
EAN-8 ... 55
EAN-8 Check Digit... 56
EAN-8 Check Digit Addenda ... 56
EAN-8 2 Check Digit Addenda ... 57
EAN-8 5 Check Digit Addenda ... 57
EAN-8 Addenda Required ...58
EAN-8 Addenda Separator...58
UPC-A/EAN-13 Extend Coupon Code ... 59
EAN.UCC Emulation ... 59
Postal Code...60
China Postal Code ...60
China Postal Code Message Length ...61
PROGRAMMING GUIDE
Korean Postal Code ... 62
Korean Postal Code Message Length ... 63
PostNet ... 63
PostNet Check Digit ...64
Planet Code ...64
Planet Code Check Digit ...65
British Post ...65
Japanese Post ...66
Canadian Post ...66
Kix Post ... 67
Australian Post ... 67
RSS (Reduced Space Symbology) ...68
RSS-14 ...68
RSS-Limited Code ... 69
RSS-Expanded Code ... 70
RSS-Expanded Code Message Length ... 70
2D Symbologies ... 71
PDF417 ... 71
PDF417 Message Length ... 71
Micro PDF417 ... 72
Micro PDF417 Message Length ... 72
TLC39 ... 73
Codablock F ... 74
Codablock F Message Length ... 74
Aztec ... 75
Aztec Message Length ... 75
Maxicode ... 76
Maxicode Message Length ... 76
Data Matrix ...77
Data Matrix Message Length ...77
QR Code ... 78
QR Code Message Length ... 78
Maintenance ... 79
Troubleshoot ... 79
Appendix A ...80
Standard Default Parameters ...80
Appendix B ...84
Code ID Table ...84
Appendix C ...85
Sample Barcodes ...85
Save ...91
Discard ...91
Appendix E ... 92
Settings and Programming
Scan selected barcodes in this manual to affect setup and programming of your handheld imaging barcode scanner. Decoding options and interface protocols can be tailored to a specific application. Setup parameters are stored in non-volatile memory in the scanner and are retained even when power is off. Setup parameters change only when you reset them.
You may need to hide adjacent code patches with your hand when scanning.
Programming Options
This section contains the following two divisions: 1. Default factory device settings.
2. Supported symbologies.
Default Factory Device Settings
User Preferences
Parameter Default
Baud Rate 115200 BPS
Word Format None, 8, 1
Illumination On
LED-Good Read On
Number of Beep-Good Read 1
Good Read Delay 200
Same Code Delay 500ms
Scan Mode Manual Trigger
Manual Mode 30000ms
Presentation 500ms
Centering Windows Off
Ship Image JPG/BMP
No Read Off
Image Reverse Off
Serial
Programming Commands
The serial programming commands can be used in place of the programming barcodes. Both the serial commands and the programming barcodes will program the engine. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual.
The device must be set to an RS-232 interface. The following commands could be sent via a PC COM PORT using terminal software
Command Format
Prefix:\x02M\x0D
Command:see the following commands list Command Format:Prefix+command Example:
Set Baud Rate to 300 Command:090D00.
Command Format:\x02M\x0D090D00.
Trigger Commands
Activate and Deactivate the scanner with serial trigger commands. Enter trigger mode, and send the following command
Activate:\x02T\x0D Deactivate:\x02U\x0D
The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been reached.
Responses
The device responds to serial commands with one of three responses ACK Indicates a good command
Interface Mode
Interface Switch
The S302D imaging barcode scanner supports USB virtual COM, USB-HID and RS232. The USB cable supports both USB virtual COM and USB-HID modes. Please install the virtual COM port driver before using USB Virtual COM.
To use USB Virtual COM for the first time, scan the USB Virtual COM barcode below and then install the Virtual COM driver.
To switch from USB Virtual Com to USB-HID mode after the virtual COM driver is installed, scan the USB HID barcode below.
To switch from USB Virtual Com to USB-HID mode if the virtual COM driver is not installed:
1. Unplug USB cable from computer.
2. Press and hold the trigger while plugging USB cable to computer. 3. Scan the USB HID barcode below.
To switch to RS232, change to RS232 interface cable and scan barcodes on next few pages to set up communication protocols.
USB HID (Default)
Baud Rate
Baud rate is the number of bits of data transmitted per second. Set the imager's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.
1200BPS 2400BPS 4800BPS 9600BPS 19200BPS 38400BPS
57600BPS
115200BPS (Default)
Word Format: Parity, Data bits, Stop bits
A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. Parity: checks character bit patterns for validity; Data bits: sets the word length; Stop bits: sets the stop bits.
None,7,1
None,7,2
None,8,1 (Default)
Even 7,1 Even 7,2 Even 8,1 Odd 7, 1 Odd 7, 2 Odd 8, 1
User Preferences
System Settings
Scan this barcode to return all parameters to the default values.
Set All Defaults
Scan this barcode to enable AUX Scanner.
Aux Scanner Enable
Scan this barcode to show scanner version.
Show Version
Beeper-Good Read
To enable or disable beeper, scan the following barcodes.
On
Off
Beeper Volume-Good Read
To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume barcode.
Off
Low Volume
Beep During Good Decode
Scan a barcode below to select the duration of the beep signal after a good decode.
Normal
Short
LED Illumination
To enable or disable LED illumination, scan the following barcodes.
On (Default)
LED-Good Read
To enable or disable LED indicator after a good read, scan the following barcodes.
On (Default)
Off
Number Of Beep-Good Read
Scan a barcode below to select the number of the beep signal to sound after a good decode.
1 (Default)
2
4
5
6
7
Good Read Delay
Scan a barcode below to set the minimum amount of time before the imager can read another barcode after a good read.
No Delay 200ms (Default) 500ms 2000ms *Specified
Same Code Delay
Scan a barcode below to set the minimum amount of time before the imager can read the same barcode a second time.
No Delay
500ms (Default)
Scan Mode
Scan a barcode below to set the imager to trigger manually or continue scanning until a barcode has been read.
Manual Trigger (Default)
Continue
Manual Mode Timeout
To a set timeout for the imager’s trigger when using Manual Trigger, scan the following “Timeout” barcode, then set the delay by scanning digits from the Appendix, then scan “Save” (Default: 30000).
Timeout (0-300,000ms)
Presentation Timeout
This option is used in Presentation mode to prevent multiple reads of a symbol left in the device’s field of view. To set the minimum amount of time before the imager can read the same barcode a second time, scan the following “Timeout” barcode then set the delay by scanning digits from the Appendix, then scan “Save” (Default: 500).
Centering Windows
To change the field of view of your imager, scan “On” to enable the feature, and then scan one of the following barcodes to change the top, bottom, left, or right of the centering window.
On
Off (Default)
Left of centering window 40%
Right of centering window 60%
Top of centering window 40%
Ship Image
To ship the image stored in the imager memory, scan the follow barcode.
JPG/BMP
No Read
Enable this function to transmit a No Read message when a code can not be read.
On
Off (Default)
Image Reverse
Enable this function to allow the imager to read barcodes that are inverted.
On
Off (Default)
Data Redundant
This function sets the imager to read the barcode multiple times before accepting data.
Data Redundant Check = Off (Default)
Data Redundant Check = 1
Data Redundant Check = 2
Data Editing
Prefix / Suffix
Prefix and Suffix are additional characters that can be sent before and after the scanned data.
Prefix
Suffix To set up Prefix/Suffix:
Prefix Set Up Flow
Ex. If we wish to add “3” as prefix for all barcode type, then follow procedure as below, Scanning [prefix] to enter setup. Then we select barcode by scanning code ID (ID table in the back) of all barcode which is [9] [9], then we scan [3] [3] as 3 of ASCII HEX. At the end, we scan [Save] to completed setup. So for full process, you scan [prefix] -> [9] [9] -> [3] [3] -> [Save].
Note: When adding a backslash (“\”or 5 C in Hex ID), please scan 5 C twice (5C5C): once to create the leading backslash and once to create the backlash itself.
Suffix Set Up Flow
Ex. If we wish to add “36” as suffix for all barcode type, then follow procedure as below, Scanning [suffix] to enter setup. Then we select barcode by scanning code ID of all barcode which is [9] [9], then we scan [3] [3] as 3 of ASCII HEX and [3] [6] as 6. Before we save, we scan command to setup terminator. If we wish to have Insert (01 from ASCII) & Enter (0A from ASCII) as terminator, we scan [0] [1] [0] [A]. To complete setup, we scan [Save]. So for full process, you scan [Suffix] -> [9] [9] -> [3] [3] -> [3] [6] -> [0] [1] -> [0] [A] -> [Save].
Note: For Suffix setup, terminator set up is required within suffix set up. If terminator is not set before save, terminator will automatically set to null.
Data Format
To change the output format, scan the following barcodes.
Data followed by <Enter> (Default)
No message after data
Data followed by <Enter> + new line
Data followed by new line
Cap Locks
To change the capital lock preferences, scan the following barcodes.
Cap Locks On
Symbologies
Introduction
This chapter describes symbology features and provides the programming barcodes for selecting these features.
The device is shipped with the settings shown in the Symbology Default Table. If the default values suit requirements, programming is not necessary.
There are two ways to change a parameter value:
Scan the appropriate barcodes in this guide. These new values replace the standard default values in memory.
For serial hosts, send a “parameter send” command from the host system. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual. Note: Most computer monitors allow scanning the barcodes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the barcode can be seen clearly and bars and/or spaces are not merging.
Message Length
The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
To set the length of a barcode symbology:
1. Scan the “Minimum” or “Maximum” barcode to enter program mode. 2. Scan the digit(s) from the ASCII table in Appendix.
3. Scan “Save” to save the change.
Note: When setting lengths for different barcode types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero.
Codabar
Codabar Enable/Disable
To set Codabar to its default settings, scan Default; to enable or disable Codabar, scan On or Off.
Default
On (Default)
Off
Codabar Stop/Start Characters
Stop/Start Characters set the leading and trailing ends of the barcode.
Don’t Transmit (Default)
Codabar Check Characters
Scan a barcode below to set the Codabar check character preferences.
No Check Character (Default)
Validate But Don’t Transmit
Validate And Transmit
Codabar Message Length
Please see Message Length on setting the message length.
Maximum (Default: 60)
Code 39
Code 39 Enable/Disable
To set Code 39 to its default settings, scan Default; to enable or disable Code 39, scan On or Off.
Default
On (Default)
Off
Code 39 Full ASCII Conversion
Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. Scan the appropriate barcode below to enable or disable it.
Off (Default)
Code 39 Append
To set the imager to append Code 39 data before transmitting to the host, scan the appropriate barcode below.
On
Off (Default)
Code 39 Check Characters
Scan a barcode below to set the Code 39 check character preferences.
No Check Character (Default)
Validate But Don’t Transmit
Code 39 Start/Stop Characters
Start/Stop Characters set the leading and trailing ends of the barcode.
Transmit
Don’t Transmit (Default)
Code 32 Pharmaceutical
To enable/ disable Code 39 Pharmaceutical, scan the appropriate barcode below.
On
Off (Default)
Code 39 Message Length
Please see Message Length on setting the message length.
Minimum (Default: 0)
Maximum (Default: 48)
Trioptic
To enable/ disable Trioptic code, scan the appropriate barcode below.
On
Off (Default)
Interleaved 2 of 5
Interleaved 2 of 5 Enable/Disable
To set Interleaved 2 of 5 to its default settings, scan Default; to enable or disable Interleaved 2 of 5, scan On or Off.
Default
On (Default)
Interleaved 2 of 5 Check Characters
Scan a barcode below to set the Interleaved 2 of 5 check character preferences.
No Check Character (Default)
Validate But Don’t Transmit
Validate And Transmit
Interleaved 2 of 5 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 80)
NEC 25
NEC 25 Enable/Disable
To set NEC 25 to its default settings, scan Default; to enable or disable NEC 25, scan On or Off.
Default
On (Default)
NEC 25 Check Characters
Scan a barcode below to set the NEC 25 check character preferences.
No Check Character (Default)
Validate But Don’t Transmit
Straight 2 of 5 Industrial
Straight 2 of 5 Industrial Enable/Disable
To set Straight 2 of 5 Industrial to its default settings, scan Default; to enable or disable Straight 2 of 5 Industrial, scan On or Off.
Default
On
Off (Default)
Straight 2 of 5 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 48)
Matrix 2 of 5
Matrix 2 of 5 Enable/Disable
To set Matrix 2 of 5 to its default settings, scan Default; to enable or disable Matrix 2 of 5, scan On or Off.
Default
On
Off (Default)
Matrix 2 of 5 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 80)
Code 11
Code 11 Enable/Disable
To set Code 11 to its default settings, scan Default; to enable or disable Code 11, scan On or Off.
Default
On
Off (Default)
Code 11 Check Characters
Scan a barcode below to set the Code 11 check character preferences.
2 Check Digit (Default)
Code 11 Message Length
Please see Message Length on setting the message length.
Minimum (Default: 4)
Maximum (Default: 80)
Code 128
Code 128 Enable/Disable
To set Code 128 to its default settings, scan Default; to enable or disable Code 128, scan On or Off.
Default
On (Default)
Off
Code 128 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 80)
Code 93
Code 93 Enable/Disable
To set Code 93 to its default settings, scan Default; to enable or disable Code 93, scan On or Off.
Default
On (Default)
Off
Code 93 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 80)
MSI
MSI Enable/Disable
To set MSI to its default settings, scan Default; to enable or disable MSI, scan On or Off.
Default
On
Off (Default)
MSI Check Characters
Scan a barcode below to set the MSI check character preferences.
Validate Type 10, Transmit
MSI Message Length
Please see Message Length on setting the message length.
Minimum (Default: 4)
Maximum (Default: 48)
Telepen
Telepen Enable/Disable
To set Telepen to its default settings, scan Default; to enable or disable Telepen, scan On or Off. Default On Off (Default)
Telepen Output
Scan a barcode below to set the Telepen Output preferences.
Original Output
Telepen Message Length
Please see Message Length on setting the message length.
Minimum (Default: 1)
Maximum (Default: 60)
UPC/EAN/JAN
UPC-A Enable/Disable
To set UPC-A to its default settings, scan Default; to enable or disable UPC-A, scan On or Off.
Default
On (Default)
Off
UPC-A Check Characters
Scan a barcode below to set the UPC-A check character preferences.
Off
UPC-A Number System
Scan a barcode below to set the UPC-A Number System preferences.
On (Default)
Off
UPC-A 2 Digit
Scan a barcode below to set the UPC-A 2 Digit preferences.
On
Off (Default)
UPC-A 5 Digit
Scan a barcode below to set the UPC-A 5 Digit preferences.
On
Off (Default)
UPC-A Addenda Required
Scan a barcode below to set the UPC-A Addenda Required preferences.
On
Off (Default)
UPC-A Addenda Separator
Scan a barcode below to set the UPC-A Addenda Separator preferences.
On (Default)
Off
UPC-E0
To set UPC-E0 to its default settings, scan Default; to enable or disable UPC-E0, scan On or Off.
Default
On (Default)
UPC-E1
Scan a barcode below to set the UPC-E1 preferences.
On
Off (Default)
UPC-E0 Expand
Scan a barcode below to set the UPC-E0 Expand preferences.
On
Off (Default)
UPC-E0 Check Digit
Scan a barcode below to set the UPC-E0 Check Digit preferences.
On (Default)
Off
UPC-E0 Number System
Scan a barcode below to set the UPC-E0 Number System preferences.
On (Default)
UPC-E0 Addenda 2 Digit
Scan a barcode below to set the UPC-E0 Addenda 2 Digit preferences.
On
Off (Default)
UPC-E0 Addenda 5 Digit
Scan a barcode below to set the UPC-E0 Addenda 5 Digit preferences.
On
Off (Default)
UPC-E0 Addenda Required
Scan a barcode below to set the UPC-A Addenda Required preferences.
Not Required (Default)
Required
UPC-E0 Addenda Separator
Scan a barcode below to set the UPC-A Addenda Separator preferences.
On (Default)
EAN/JAN-13
To set EAN/JAN-13 to its default settings, scan Default; to enable or disable EAN/JAN-13, scan On or Off.
Default
On (Default)
Off
EAN/JAN-13 Check Digit
Scan a barcode below to set the EAN/JAN-13 Check Digit preferences.
Off
On (Default)
EAN/JAN-13 2 Check Digit Addenda
Scan a barcode below to set the EAN/JAN-13 2 Check Digit Addenda preferences.
On
Off (Default)
EAN/JAN-13 5 Check Digit Addenda
Scan a barcode below to set the EAN/JAN-13 5 Check Digit Addenda preferences.
On
Off (Default)
EAN/JAN-13 Addenda Required
Scan a barcode below to set the UPC-A Addenda Required preferences.
Not Required (Default)
Required
EAN/JAN-13 Addenda Separator
Scan a barcode below to set the UPC-A Addenda Separator preferences.
On (Default)
IBSN Translate
Scan a barcode below to set the IBSN Translate preferences.
On
Off (Default)
EAN-8
To set EAN -8 to its default settings, scan Default; to enable or disable EAN-8, scan On or Off.
Default
On (Default)
EAN-8 Check Digit
Scan a barcode below to set the EAN-8 Check Digit preferences.
On (Default)
Off
EAN-8 Check Digit Addenda
Scan a barcode below to set the EAN-8 Check Digit Addenda preferences.
On
Off (Default)
EAN-8 2 Check Digit Addenda
Scan a barcode below to set the EAN-8 2Check Digit Addenda preferences.
On
Off (Default)
EAN-8 5 Check Digit Addenda
Scan a barcode below to set the EAN-8 5 Check Digit Addenda preferences.
On
Off (Default)
EAN-8 Addenda Required
Scan a barcode below to set the EAN-8 Addenda Required preferences.
Not Required (Default)
Required
EAN-8 Addenda Separator
Scan a barcode below to set the EAN-8 Addenda Separator preferences.
On (Default)
UPC-A/EAN-13 Extend Coupon Code
Scan a barcode below to set the UPC-A/EAN-13 Extend Coupon Code preferences.
On
Off (Default)
EAN.UCC Emulation
Scan a barcode below to set the EAN.UCC Emulation preferences.
Off (Default)
EAN.UCC-128 Emulation
Postal Code
Note: For best performance when reading a postal code, please enable only one postal symbology and disable the rest.
To enable or disable a postal code, please scan the following barcode first to enter programming mode, then scan the On or Off barcode for your postal code.
Postal Code
China Postal Code
To set China Postal Code to its default settings, scan Default; to enable or disable China Postal Code, scan On or Off.
Default
On
Off (Default)
China Postal Code Message Length
Please see Message Length on setting the message length.
Minimum (Default: 4)
Maximum (Default: 80)
Han Xin Code
To set Han Xin Code to its default settings, scan Default; to enable or disable Han Xin Code, scan On or Off.
Default
On
Han Xin Code Message Length
Please see Message Length on setting the message length.
Minimum (Default: 1)
Maximum (Default: 7873)
Korean Postal Code
To set Korean Postal Code to its default settings, scan Default; to enable or disable Korean Postal Code, scan On or Off.
Default
On
Korean Postal Code Message Length
Please see Message Length on setting the message length.
Minimum (Default: 4)
Maximum (Default: 48)
PostNet
Scan a barcode below to enable or disable PostNet.
On
Off (Default)
PostNet Check Digit
Scan a barcode below to set the PostNet Check Digit preferences.
Not Transmit (Default)
Transmit
Planet Code
Scan a barcode below to enable or disable Planet Code.
On
Off (Default)
Planet Code Check Digit
Scan a barcode below to set the Planet Code Check Digit preferences.
Don’t Transmit (Default)
Transmit
British Post
Scan a barcode below to enable or disable British Post code.
On
Off (Default)
Japanese Post
Scan a barcode below to enable or disable Japanese Post code.
On
Off (Default)
Canadian Post
Scan a barcode below to enable or disable Canadian Post code.
On
Off (Default)
Kix Post
Scan a barcode below to enable or disable Kix Post code.
On
Off (Default)
Australian Post
Scan a barcode below to enable or disable Australian Post code.
On
Off (Default)
RSS (Reduced Space Symbology)
The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and
expanded versions have stacked variants. Scan the appropriate barcode below to enable or disable each variant of RSS.
RSS-14
To set RSS-14 to its default settings, scan Default; to enable or disable RSS-14, scan On or Off.
Default
On (Default)
RSS-Limited Code
To set Limited Code to its default settings, scan Default; to enable or disable RSS-Limited, scan On or Off.
Default
On (Default)
RSS-Expanded Code
To set Expanded Code to its default settings, scan Default; to enable or disable RSS-Expanded, scan On or Off.
Default
On (Default)
Off
RSS-Expanded Code Message Length
Please see Message Length on setting the message length.
Maximum
2D Symbologies
PDF417
To set PDF417 to its default settings, scan Default; to enable or disable PDF417, scan On or Off. Default On (Default) Off
PDF417 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 2750)
Micro PDF417
To set Micro PDF417 to its default settings, scan Default; to enable or disable Micro PDF417, scan On or Off.
Default
On
Off (Default)
Micro PDF417 Message Length
Please see Message Length on setting the message length.
Maximum (Default: 366)
TLC39
Scan a barcode below to enable or disable TLC39.
On
Off (Default)
Codablock F
To set Codablock F to its default settings, scan Default; to enable or disable Codablock F, scan On or Off.
Default
On
Off (Default)
Codablock F Message Length
Please see Message Length on setting the message length.
Maximum (Default: 2048)
Aztec
To set Aztec to its default settings, scan Default; to enable or disable Aztec, scan On or Off.
Default
On (Default)
Off
Aztec Message Length
Please see Message Length on setting the message length.
Maximum (Default: 3832)
Maxicode
To set Maxicode to its default settings, scan Default; to enable or disable Maxicode, scan On or Off.
Default
On
Off
Maxicode Message Length
Please see Message Length on setting the message length.
Maximum (Default: 150)
Minimum (Default: 1)
Data Matrix
To set Data Matrix to its default settings, scan Default; to enable or disable Data Matrix, scan On or Off.
Default
On (Default)
Off
Data Matrix Message Length
Please see Message Length on setting the message length.
Maximum (Default: 3116)
QR Code
To set QR Code to its default settings, scan Default; to enable or disable QR Code, scan On or Off.
Default
On (Default)
Off
QR Code Message Length
Please see Message Length on setting the message length.
Maximum (Default: 7089)
Minimum (Default: 1)
Maintenance
Cleaning the scan window is the only maintenance required. A dirty window may affect scanning accuracy.
Never use any abrasive material or solvents on the window. Do not spray water or other cleaning liquids directly onto the window.
Remove dirt by wiping gently with a damp cloth or tissue moistened with water and/or ammonia.
Troubleshoot
Follow the table below for ways to switch interface when the cable is missing. USB mode to RS232 mode USB mode to USB Virtual COM RS232 to USB mode
Default Multi-interfaces Mode already cover both USB & RS-232 interfaces
No power, (hold the trigger, re-plug USB cable, power on to scan mode switch barcode commands and working properly)
Default Multi-interfaces Mode already cover both USB & RS-232 interfaces
Appendix A
Standard Default Parameters
Symbology Default
Codabar Enable
Code 39 Enable
Code 39 Full ASCII Disable
Code 39 Append Disable
Code 39 Check Char No check char Code 39 start/stop char Don’t transmit Code 32 Pharmaceutical Disable Code 39 Message Length 0~48
Interleaved 2 of 5 Enable
Interleaved 2 of 5 Check Char No check char Interleaved 2 of 5 Message
Length 4~80
NEC 25 Enable
NEC 25 Check Char
No check char Straight 2 of 5 Industrial Disable Straight 2 of 5 Industrial
Message 4~48
Straight 2 of 5 Industrial IATA Disable Straight 2 of 5 Industrial IATA
Message Length 4~48
Matrix 2 of 5 Disable
Matrix 2 of 5 Message Length 4~80
Code 11 Disable
Code 11 Message Length 4~80
Code 11 Check Char 2 check digits
Code 128 Message Length 0~80
Code 93 Enable
Code 93 Message Length 0~80
MSI Disable
MSI Message Length
4~48
MSI Check Char Validate Type 10,
Don’t Transmit
Telepen Disable
Telepen Output AIM output
Telepen Message Length 1~60
UPC-A Enable
UPC-A Check char Enable
UPC-A Number System Enable
UPC-A 2 digit Disable
UPC-A 5 digit Disable
UPC-A Addenda Required Disable UPC-A Addenda Separator Enable
UPC-E0 Enable
UPC-E1 Disable
UPC-E0 Expand Disable
UPC-E0 Check digit Enable
UPC-E0 Number System Enable UPC-E0 Addenda 2 digit Disable UPC-E0 Addenda 5 digit Disable UPC-E0 Addenda Required Not required UPC-E0 Addenda Separator Enable
EAN/JAN-13 Enable
EAN/JAN-13 2 Check Digit
Addenda Disable
EAN/JAN-13 5 Check Digit
Addenda Disable
EAN/JAN-13 Addenda
Required Not required
EAN/JAN-13 Addenda
Separator Enable
IBSN Translate Disable
EAN-8 Enable
EAN-8 Check Digit Enable
EAN-8 2 Check Digit Addenda Disable EAN-8 5 Check Digit Addenda Disable EAN-8 Addenda Required Not required EAN-8 Addenda Separator Enable UPC-A/EAN-13 Extend Coupon
Code Disable
EAN.UCC Emulation Disable
China Postal Code Disable
China Postal Code Message
Length 4~80
RSS-14 Enable
RSS-Limited Code Enable
RSS-Expanded Code Enable
RSS-Expanded Code Message
Length 4~74
Trioptic Code Disable
PDF417 Enable
PDF417 Message Length 1~2750
Micro PDF417 Disable
Micro PDF417 Message Length 1~366
Codablock F Disable Codablock F Message Length 1~2048
Aztec Enable
Aztec Message Length 1~3832
Maxicode Enable
Maxicode Message Length 1~150
Data Matrix Enable
Data Matrix Message Length 1~3116
QR Enable
QR Message Length 1~7089
Han Xin Code Disable
Han Xin CodeMessage Length 1~7873
Korean Postal Code Disable
Korean Postal Code Message
Length 4~48
PostNet Disable
PostNet Check Digit Don’t transmit
Planet Code Disable
Planet Code Check Digit Don’t transmit
British Post Disable
Japanese Post Disable
Canadian Post Disable
Kix Post Disable
Appendix B
Code ID Table
Symbology Code ID Code ID in HEX
Code 128 j 6A GS1-128(UCC/EAN-128) j 6A AIM-128 f 66 EAN-8 d 64 EAN-13 d 64 ISSN n 6E ISBN B 42 UPC-E c 63 UPC-A c 63 Interleaved 2 of 5 e 65 ITF-6 e 65 ITF-14 e 65 Matrix 2 of 5 v 76 Industrial 2 of 5 D 44 Standard 2 of 5 s 73 Code 39 b 62 Codabar a 61 Code 93 i 69 Code 11 H 48 GS1 Databar R 52 PDF417 r 72 QR Code Q 51 Data Matrix u 75 All 99
Appendix C
Sample Barcodes
Canada Post 4-State
01,K1A0B1,7010,
Japan Post 4-State
80342716666
US POSTNET
8034271888
Australian Post
8034271999
Dutch Post - Royal TPG Post KIX 4-State
1231FZ13XHS
USPS PLANET Barcode
4012345235636
British Royal Mail 4-State BPO
Infomail Mail 4-State
Sweden Post 4-State
USPS 4-state (Intelligent Mail)
Barcode ID...82
Service Type ID....152
Mailer ID...568794
Serial Number...748970563
ZIP Code...12789600178
Barcode ID...00
Service Type ID....311
Mailer ID...000479
Serial Number...612518080
ZIP Code...20724170703
Barcode ID...20
Service Type ID....301
Mailer ID...901212001
Serial Number...311323
Appendix D
Numeric Barcodes
For parameters requiring specific numeric values, scan the appropriately numbered barcode(s).
0
1
2
5
6
7
8
B C D E F
Save
To save the setting, scan the barcode below.
Save
Discard
To correct an error or change a selection, scan the barcode below.
Appendix E
Full ASCII Table
ASCII Hexacode ASCII Hexacode
Full ASCII ---NUL 00 Full ASCII ---SI
Function key---“Shift” 0F Full ASCII ---SOH
Function key---“Ins” 01
Full ASCII ---DLE
Function key---“5(num)” 10 Full ASCII ---STX
Function key---“Del” 02
Full ASCII ---DC1
Function key---“F1” 11
Full ASCII ---ETX
Function key---“Home” 03
Full ASCII ---DC2
Function key---“F2” 12
Full ASCII ---EOT
Function key---“End” 04
Full ASCII ---DC3
Function key---“F3” 13
Full ASCII ---ENQ
Function key---“Up arrow” 05
Full ASCII ---DC4
Function key---“F4” 14
Full ASCII ---ACK
Function key---“Down arrow”
06 Full ASCII ---NAK Function key---“F5”
15 Full ASCII ---BEL
Function key---“Left arrow”
07 Full ASCII ---SYN Function key---“F6”
16 Full ASCII ---BS
Function key---“Backspace”
08 Full ASCII ---ETB Function key---“F7”
17 Full ASCII ---HT
Function key---“TAB”
09 Full ASCII ---CAN Function key---“F8”
18 Full ASCII ---LF
Function key---“Enter (alpha numeric)”
0A Full ASCII ---EN Function key---“F9”
19
Full ASCII ---VT
Function key---“right arrow”
0B Full ASCII ---SUB Function key---“F10”
1A Full ASCII ---FF
Function key---“PgUp”
0C Full ASCII ---ESC Function key---“F11” 1B Full ASCII ---CR Function key---“Enetr(num.)” 0D Full ASCII ---FS Function key---“F12” 1C Full ASCII ---SO
Function key---“PgDn”
0E Full ASCII ---GS Function key---“ESC”
Full ASCII ---RS
Function key---“CTL(L)”
1E Full ASCII ---- 2D
Full ASCII ---US
Function key---“ALT(L)”
1F Full ASCII ---. 2E
Full ASCII ---SP 20 Full ASCII ---/ 2F
Full ASCII ---! 21 Full ASCII ---0 30
Full ASCII ---“ 22 Full ASCII ---1 31
Full ASCII ---# 23 Full ASCII ---2 32
Full ASCII ---$ 24 Full ASCII ---3 33
Full ASCII ---% 25 Full ASCII ---4 34
Full ASCII ---& 26 Full ASCII ---5 35
Full ASCII ---‘ 27 Full ASCII ---6 36
Full ASCII --- ( 28 Full ASCII ---7 37
Full ASCII ---) 29 Full ASCII ---8 38
Full ASCII ---* 2A Full ASCII ---9 39
Full ASCII ---+ 2B Full ASCII ---: 3A
Full ASCII ---, 2C Full ASCII ---; 3B
Full ASCII ---< 3C Full ASCII ---K 4B
Full ASCII ---= 3D Full ASCII ---L 4C
Full ASCII ---> 3E Full ASCII ---M 4D
Full ASCII ---@ 40 Full ASCII ---O 4F
Full ASCII ---A 41 Full ASCII ---P 50
Full ASCII ---B 42 Full ASCII ---Q 51
Full ASCII ---C 43 Full ASCII ---R 52
Full ASCII ---D 44 Full ASCII ---S 53
Full ASCII ---E 45 Full ASCII ---T 54
Full ASCII ---F 46 Full ASCII ---U 55
Full ASCII ---G 47 Full ASCII ---V 56
Full ASCII ---H 48 Full ASCII ---W 57
Full ASCII ---I 49 Full ASCII ---X 58
Full ASCII ---J 4A Full ASCII ---Y 59
Full ASCII ---Z 5A Full ASCII ---i 69
Full ASCII ---[ 5B Full ASCII ---j 6A
Full ASCII ---\ 5C Full ASCII ---k 6B
Full ASCII ---] 5D Full ASCII ---l 6C
Full ASCII ---^ 5E Full ASCII ---m 6D
Full ASCII ---_ 5F Full ASCII ---n 6E
Full ASCII ---` 60 Full ASCII ---o 6F
Full ASCII ---b 62 Full ASCII ---q 71
Full ASCII ---c 63 Full ASCII ---r 72
Full ASCII ---d 64 Full ASCII ---s 73
Full ASCII ---e 65 Full ASCII ---t 74
Full ASCII ---f 66 Full ASCII ---u 75
Full ASCII ---g 67 Full ASCII ---v 76
Full ASCII ---h 68 Full ASCII ---w 77
Full ASCII ---x 78 Full ASCII ---| 7C
Full ASCII ---y 79 Full ASCII ---} 7D