(1)

alpha

®

DSL WTM EG

Instructions for use

ADSL-Modem

alpha DSL WTM EG

(2)

Safety precautions

Safety precautions

The DSL modem alpha DSL WTM EG complies with the European norm EN60950 –safety of information technology equipment. The safe construction makes sure that persons or objects are not endangered.

l

Do not open the unit, only permit repairs by authorised specialists!

l

Do not use or install your unit in rooms with explosive material!

l

Do not touch the device terminals with metallic or sharp objects!

l

The last step when putting the unit into operation is to plug in the

DSL plug or the LAN plug and the 230 V plug into the appropriate

sockets after mounting!

l

The first step when ending operation is to remove the 230 V plug and

then the plug of the DSL connection cord or the LAN cord from the

sockets!

l

The connection cables of the unit may only be plugged into the

designated sockets!

l

In case the unit is damaged, it may not be put into operation, there is

an immediate danger to life because of an electric shock. In case the

power supply unit is damaged, you should first remove the fuse of the

respective electric circuit in order to be able to remove the power

supply unit without danger and replace it by another unit, if necessary!

l

Never install the unit during a thunderstorm!

l

Protect the unit from heat sources and direct sunlight!

l

Protect the unit from dust, humidity, aggressive liquids and steam!

l

The unit may only be connected to approved accessories!

l

When cleaning the unit with an antistatic cloth or with a soft, slightly

moistened cloth, make sure that it is disconnected from the mains

voltage 230 V~!

l

The unit should only be passed on to a third party including complete

operating instructions!

l

When the DSL modem alpha DSL WTM EG has reached the end of its

service life, it has to be disposed of in an environmentally friendly

manner!

(3)

alpha DSL WTM EG

alpha DSL WTM EG

type plate

3

2

1

LEDs:

1 DSL LED for the condition of the DSL connection

2 Power LED for the operating condition of the modem

3 LAN LED for the condition of the LAN connection Version see type plate:

l version alpha DSL WTM EG A for ITUG.992.1 Annex A

l version alpha DSL WTM EG B for ITUG.992.1 Annex B (G.dmt 1TR112 (UR2))

Checking the content of the package

Delivery scope:

l DSL modem alpha DSL WTM EG

l wall power supply

l 2 pieces RJ45 connection cable (2 m)

l 2 pieces fastening angles including screws, washers and nuts

(4)

Connection

Connecting the alpha DSL WTM EG

In the following picture you can see how you have to cable the alpha DSL WTM EG:

to the power supply unit splitter

to the PC

1. Connect Ethernet socket at alpha DSL WTM EG as well as LAN socket at PC (net-work card/ optionally switch / hub) or router with first RJ45 patch cable

2. Connect splitter as well as alpha DSL WTM EG with second RJ45 patch cable 3. Connect power supply unit 12 VDC / 1.25 A to alpha DSL WTM EG and then plug

in 230 V socket.

Information:

The RJ45 patch cables can be exchanged with one another.

Note:

The use of network devices that are not approved can lead to the destruction of the

alpha DSL WTM EG.

Connecting sockets

The alpha DSL WTM EG has the following connecting sockets:

1. Ethernet connecting socket RJ45 / standard Ethernet connection for computers or network devices with 10 or 100 Mbit/s

2. DSL connecting socket RJ45 for the connection to the DSL splitter 3. 12 VDC / 1.25 A connecting socket for the provided wall power supply

(5)

Connection

Power

DSL

LAN

ADSL in Ethernet Power

12 VDC 1,25A

alpha DSL WTM EG

1

2

3

Assignment of the LAN and DSL connecting socket:

PIN 8

PIN 1

LAN connecting socket Contact PIN Assigned with 1 RX+ (Receive +) 2 RX- (Receive -) 3 TX + (Transmit +) 4 not used

5 not used 6 TX – (Transmit -) 7,8 not used

Assignment of the Power socket:

PIN 2

PIN 1

Contact PIN Assigned with 1 0 V (GND)

2 + 12 V

DSL connecting socket Contact PIN Assigned with 1,2,3 not used 4 DSL signal 5 DSL signal 6,7,8 not used

(6)

Mounting / Drilling template

Mounting

By means of the fastening angles that are included in the delivery, it is possible to attach the alpha DSL WTM EG to a wall or something similar. The fastening angles are to be attached to the housing of the alpha DSL WTM EG as shown in the following picture. For this, insert the M5-square nuts in die lateral profile slots of the housing and screw on the fastening angles.

Drilling template

205 190

80

6.5

4.5

4.5

225

14

(7)

Putting into operation

Putting into operation and LEDs

Required software drivers

The communication between PC and DSL over the LAN connection is realized by means of PPPoE (Protocol Point to Point over Ethernet).

The driver required for this has to be installed and activated on the PC to which the DSL modem is connected.

Note:

The PPPoE driver for current Windows versions can be downloaded e.g. from the website www.raspppoe.com.

After correct cabling of the alpha DSL WTM EG, the following status indications should be visible at the front of the alpha DSL WTM EG (see picture page 3):

Status indication Meaning

Power Supply voltage available

DSL blinking DSL training / dialogue between alpha DSL WTM EG and exchange / max. 10 min

DSL – glowing

permanently alpha DSL WTM EGnisation with exchange is terminated without data is registered, training / synchro-error

(8)

Troubleshooting

Status indication Possible cause Measures The power LED is not

glowing. The has no power supply. alpha DSL WTM EG 1. Check the correct cabling between alpha DSL WTM EG and power supply 230 V socket. [optionally 110 V socket]

2. The alpha DSL WTM EG has to be exchanged.

DSL - not blinking 40 s after correct connection

DSL connection faulty Contact provider

DSL– blinking longer

than 10 min Connection cable defective or not inserted correctly 1. Check the connection cable or the patch cable between alpha DSL WTM EG and splitter 2. Check the cable connection at splitter and alpha DSL WTM EG/ cable shall snap safely into place LAN-LED is not

glowing

Connection cable defective or not inserted correctly

1. Check the connection cable or the patch cable between alpha DSL WTM EG and PC / LAN terminal

2. Check the cable connection at splitter and alpha DSL WTM EG / cable shall snap safely into place

(9)

Conformity

Conformity

Herewith, the FMN communications GmbH sthat the alpha DSL WTM EG complies with the essential requirements and the other relevant provisions of the

directive 1999/5/EG (R&TTE directive).

The conformity with the above mentioned directive is confirmed by the CE symbol on the unit.

The complete declaration of conformity can be found in the Internet under

(10)

Maintenance / Technical data

Maintenance

No maintenance is necessary at the alpha DSL WTM EG.

In case the mains supply is switched off (power supply unit is disconnected from the 230 V socket), the alpha DSL WTM EG can be cleaned with an antistatic cloth or with a soft, dry cloth.

The alpha DSL WTM EG may only be repaired by the manufacturer or by authorized specialists.

Technical data of the DSL modem

l Dimensions (W x D x H): approx. (159 x 144 x 64) mm

l Protection class: IP 54

l Operating voltage: 230 volt / 50 hertz

l Maximum power consumption: 10 W

l Average power consumption: 6 W

l Operating temperature: -25 °C .... +55 °C

l DSL transmission rate: max. 24 MBit/s (Downstream),

1 MBit/s (Upstream)

l Software (firmware) can only be updated by the manufacturer or authorized specialists

l Compliant to CE Connections and interfaces

l DSL connection according to standard ITU G.992.1 Annex B (G.dmt), T-Com 1TR112, ANSI T1.413, ITU G.994.1 (G.hs) / Annex A

(11)

Copyright

All rights reserved. Duplication of these instructions for use or parts thereof by any repro-duction method whatsoever is not permitted without prior permission of the manufacturer. Amendments may be published without prior notification.

Notwithstanding the above declaration, the manufacturer accepts no liability for errors in these instructions or their consequences.

(12)

For the protection of the environment!

Printed on paper bleached without chlorine, with a maximum waste paper content of 50 %.

FMN communications GmbH

Grimmelallee 4 99734 Nordhausen/Germany P. O. Box 10 04 65 99724 Nordhausen/Germany Phone +49 (36 31) 56-50 00 Fax +49 (36 31) 56-32 24 Email info@fmn.de Internet www.fmncom.com

HOTLINE

+49 (36 31) 56-34 16

We are at your disposal to answer your questions. Subject to change.

References

Related documents

Objective of this project is to allocate the chunks of files as uniformly as possible among the nodes such that no node manages an excessive number of chunks and also to reduce

300Mbps Wireless N VoIP VDSL/ADSL Modem Router TD-VG5612. · DSL Port – For VDSL2/VDSL/ADSL2+/ADSL2/

Abstract. In this paper, we examine the effect of product variety on inventory costs in a production– inventory system with finite capacity where products are made to stock and

L If you use a DSL/ADSL service, we recommend connecting a filter (contact your DSL/ADSL service provider) to the telephone line between the base unit and the telephone line

• Digital Subscriber Line (DSL) is the family of technologies that provide digital data over the copper wires of a local telephone network.. • The copper telephone network

Connect power supply cable to power connector and then plug in to alpha DSL..

In situ synthesized ceramic compos- ites provide good trade-off between dielectric/magnetic constants and dielectric/magnetic loss and allow to op- timize their intrinsic impedance

For the most basic setup of your ADSL hardware, with just one BT Telephone socket running one Telephone and your ADSL Router/Modem, all you require is the one DSL Filter.. This