M A X S Y S

s

s

C O M P R E H E N S I V E S E C U R I T Y

T H A T ’ S N O T C O M P L I C A T E D

Managing a business takes a lot of work, passion and commitment. That’s why it’s

important that the same effort be made when choosing a security system. After all,

properly protecting the people and other valuable assets that comprise a successful

business are not something you want to jeopardize.

There was a time when building security consisted of little more than burglar alarms,

motion detectors and a few smoke detectors. Clearly times have changed and the

need for a premium security system is real.

In keeping with new times and new technologies, DSC has defined the meaning of

security, as is evident with MAXSYS. The security system allows a host of value-added

and life-safety features to be integrated to provide peace of mind for years to come.

Security concerns, whether they are intrusion, fire, alarm communications, access

control, automation, wireless/addressable expansion or structured cabling, can be tailored

to meet specific needs. MAXSYS is truly a single-system solution that is ideal for

commercial, industrial and institutional facilities, as well as large or multi-level

residential units.

Fully integrated security solutions

High-end premium quality security

(4)

M A X S Y S

I N T R U S I O N C O N T R O L P A N E L S

Every business is unique. With MAXSYS you

can choose the best combination of

technologies to expand security needs

as necessary.

COMBUS expansion

Addressable loop expansion

Wireless expansion

16-128 Zone Control Panel

PC4020

• 16 zones on main control panel • Supports up to 16 hardwired keypads • Expandable to 128 zones using hardwire,

wireless modules and addressable zones • COMBUS hardwired expansion

• 8 partitions

• 1,500 user codes (4 or 6 digit) • 3,000-event buffer

• 9 account and 3 phone numbers • 1 supervised bell zone

• Built-in telephone line and siren supervision

• Auto SIA and Contact ID formats • Supports SKYROUTEMAX™ and

T-Link™TL250/T-Link Internet and network alarm communicators

• Full upload/download support with DLS download software

K E Y P A D S

MAXSYS LCD keypads put security and convenience

at your fingertips. The keypad offers end-users

simple one-button activation of five programmable

function keys. For urgent situations,

keypad-activated emergency keys send an alarm signal to

the central monitoring station, which in turn,

notifies the proper authority (police, fire or

emergency services).

Programmable-Message LCD Keypad

LCD4501

• Connect up to 16 keypads

• Large, back-lit, 2-line, 32-character display • Plain-language display of zone status, system

status, trouble conditions, event buffer, system instructions, date and time • Ready, Armed and Trouble LEDs • 5 programmable function keys • 4 keypad-activated alarms:

- Panic, Auxiliary, Fire and Duress

• Backlight boost

s

s

(5)

M A X S Y S

Internet Alarm Communicator

T-LINK TL250

The simple-to-install Internet alarm communicator saves customers money by taking advantage of their existing Internet/Intranet networks to create fully supervised security solutions between protected premises and the central monitoring station. No other communication network needs to be created. And with industry-leading 128-bit AES encryption, customers can be assured that they are getting the most secure Internet alarm communicator available.

Network Alarm Communicator

T-LINK

A low-cost alternative to traditional phone line alarm communication, T-Link works within the existing Intranet (LAN/WAN) of businesses to securely communicate alarm signals to a central monitoring station. This is an ideal application for large retail chains or campus-style installations where significant networks have already been established and are being used for various purposes.

• Multiple receivers for larger coverage and overlaps

• New technology for greater signal range and accuracy

• Long-life lithium batteries • Attractive, compact designs • Easy to install, program and use

• Revolutionary reliability and wireless convenience

W I R E L E S S E X P A N S I O N

Use the PC4164-433 wireless receiver to support up

to 64 wireless zones and 16 wireless keys. Up to

eight backup receivers can be installed on one

system. Choose wireless devices from the innovative

new line-up of DSC wireless solutions.

Technologically advanced products such as wireless

keys, smoke detectors, and a host of detectors and

modules are available for installation. All wireless

devices are fully supervised for communication

integrity and can be configured according to the

security needs of every imaginable circumstance,

providing double-safe protection with

outstanding features:

I N T E R N E T & N E T W O R K

A L A R M C O M M U N I C A T O R S

In the same way that cellular telephones, pagers

and handheld PDAs have revolutionized personal

communications, the DSC T-Link family of Internet

and network alarm communicators provides

end-users with the highest levels of

(6)

M A X S Y S

A D D R E S S A B L E L O O P E X P A N S I O N

The Addressable Multiplexed Loop (AML) provides the ultimate in simple, flexible and affordable zone

expansion. Save time and money by connecting any addressable detector anywhere on the two-wire

AML loop to create up to 128 addressable zones.

Addressable Passive Infrared Detector

AMB-300

• Based on the Bravo®3 hardwire motion detector

• Patented MLSP (Multi-Level Signal Processing) • Interchangeable lenses:

- Wall-to-wall lens (standard), curtain lens, pet-immune lens and corridor lens

• Built-in tamper switch

Addressable Pet-Immune Passive

Infrared Detector

AMB-600

• Based on the Bravo®6 hardwire motion detector

• Patented MLSP (Multi-Level Signal Processing) • Provides pet immunity up to 85 lbs (38 kg) • Built-in tamper switch

Addressable Ceiling-Mount Passive

Infrared Detector

AMB-500

• Based on the Bravo®5 hardwire motion detector

• Patented MLSP (Multi-Level Signal Processing) • Coverage diameter based on mounting height • Built-in tamper switch

Addressable Glassbreak Detector

AMA-100

• Based on the AcuityTM

hardwire glassbreak detector

• Detects all types of breaking glass

- Plate, laminated, safety and tempered

• Can be tested using the glassbreak simulator (AFT-100)

• Built-in tamper switch

Addressable Photoelectric Smoke Detectors

FSB-210 SERIES

• Automatic drift compensation

• Easy-maintenance removable smoke chamber • Non-contact sensitivity reading with

handheld test meter (FSD-100) • Self diagnostics

• UL listed

Addressable Point / Contact Modules

AMP-700 / AMP-701NP / AMP-702 / AMP-704

• AMP-700 door/window contact with built-in reed switch

• AMP-701 door/window contact with normally closed input

• AMP-701NP universal addressable point module • AMP-702 fire point module with normally

open, EOL resistor supervised input • AMP-704 4-door/window contacts with

normally closed, single or double EOL inputs • AMP-704F 4-zone normally open fire input module

Loop Repeater / Isolator Modules

AMX-400 / AMX-400PS

• Can be used to repeat and re-power the AML loop to allow for longer wire runs:

- Requires 12 VDCpower source

• Will isolate the wire run in the event of a problem • Adds additional 170 mA

• AMX-400PS includes all the same features as the AMX-400 plus power supply

Loop Isolator Module

AML-770

• Can be used to isolate burglary detectors from fire detectors on the same wire run

(7)

M A X S Y S

D A T A I N T E R F A C E M O D U L E

With the installation of data interface modules (PC4401), MAXSYS control panels are able to interface with

leading manufacturers of home and building automation products and audio distribution systems to create

seamless, fully integrated control solutions.

Data Interface Module

PC4401

• Capable of performing as either a bi-directional RS-232 interface, PC-Link isolator, printer module or DVACS®

* communicator (Canada only)

M O D U L E S

MAXSYS zone expanders can add eight zones or 16 zones where needed. Simply connect them

to the COMBUS for flexible, efficient and distributed zone expansion.

8 / 16 Hardwire Zone Expanders

PC4108 / PC4116

• PC4108 adds 8 hardwire zones • PC4116 adds 16 hardwire zones • AUX power rated at 250 mA

(PTC protected)

Power Supply / Relay

Output Module

PC4204CX

• Connect up to 16 modules • Fully supervised for AC failure,

low battery and AUX failure • 4 programmable form ‘C’ relays:

- Rated at 3 Amps @ 12 VDC

P O I N T & G R A P H I C A N N U N C I A T O R S

When emergencies occur, make certain operating and emergency personnel are able to understand the nature

of an alarm and are able to communicate the information needed for swift and effective action. With MAXSYS

point and graphic annunciators, context-sensitive information is never more than a glance away. The

annunciators can display up to 144 zone, partition and system events.

32 / 64 Point & Graphic Annunciators

PC4632 / PC4664

• Egg-crate backplate for flexible LED locations • Pre-printed point display transparency • Clear transparencies (2) for custom graphics

• Real-time zone status • Fully programmable • 4-wire hook-up to COMBUS

* DVACS is a registered trademark of Electro Arts Ltd. Scarborough, Ontario, Canada.

16-Output Module

PC4216

• Provides 16 programmable outputs:

- Rated at 50 mA @ 12 VDC

• Connect up to 9 PC4216 modules per system

(8)

M A X S Y S

Commercial Fire Panel

PC4020CF

• Includes all the features of the PC4020 plus:

- PC4050CR cabinet - PC4701 module

- Built-in 16 VAC, 40 VA transformer

Programmable Fire-Message LCD Keypad

LCD4521

• Includes all the features of the LCD4501 keypad • Red bezel

• Fire function keys:

-Silence Trouble, Silence Bells, Fire Reset, Fire Drill and Lamp Test

Dual-Line Dialer Module

PC4701

• Dual, supervised phone line connections • 1 2-wire Class B/Style B supervised

smoke alarm zone

• 1 Class B/Style B waterflow zone • Fire alarm and fire trouble form ‘C’ relays

External Battery Charger

PS4350R

• Includes PS4085 multi-rate charger module • Includes PT1012 transformer, 12 VDC, 160 VA

• Space for 60 Ah of rechargeable batteries

Commercial Fire Power Supply

PC4204CXCF

• Includes all the features of the PC4204CX • Includes PC4052CR cabinet

• Built-in 16 VAC, 40 VA transformer

Dual-Zone Bell Panel

PC4702BP

• Connect up to 4 modules

• Provides 2 alarm notification circuits: -Rated at 1.8 Amps @ 24 VDCeach

• Fully supervised outputs for open, short and ground fault

• PTC protected • Includes:

- PC4052CR red cabinet - 28 VAC, 180 VA transformer

M A X S Y S F I R E P R O D U C T S

MAXSYS fire products provide all the equipment

needed to integrate full commercial fire into any

security application.

(9)

M A X S Y S

2-Reader Access Control Module

PC4820

• Connect up to 16 modules • Multiple reader technologies • 2 supervised lock outputs:

- 250 mA per output

• 64 user access levels • 99 date schedules • 4 holiday groups

• Arm/Disarm partitions via access control • PC4053 beige cabinet included

A C C E S S C O N T R O L

Monitoring and restricting the individual entry of tens or

perhaps a thousand people within a building is not easy. To

protect it from theft or damage, MAXSYS allows simple and

affordable access control integration with its alarm systems.

Readers

• MAXSYS supports a wide variety of 26-bit Weigand and Kantech XSF Technology readers including:

- Polaris™, ioProx™, Shadowprox™ and HID

M A X S Y S A C C E S S C O N T R O L K I T

This affordable package is the perfect access control

starter kit. It has all the essentials you need: control

panel, access control module, reader and cards in one

low-cost package. And, if needed, the system can be

easily expanded.

• 1 PC4020 control panel • 1 PC4820 access control module • 1 P225W26 ioProx reader • 10 P40KEY ioProx dual-encoded

proximity keys

Request-to-Exit Detector

T-REX™

• Passive infrared request-to-exit detector with patented X-Y Targeting™and DSP

(10)

M A X S Y S

Telephone Interface & Automation

Control Module

ESCORT™ PC4580

• Turns any touchtone telephone into a talking keypad

• Programmable labels:

- 6 words per label - 240+ word library

• Built-in X-10 interface:

- Supports up to 32 x-10 devices - 16 schedules, 8 modes

• Available in English, Spanish and French

C O N C O U R S E E

E X

X P

P

S T R U C T U R E D C A B L I N G

ConcourseEXP is the best value in residential structured

cabling. It provides new home builders and home-system

integrators with the convenience of a single, comprehensive

family of cable management products that are easy to use in

applications of all sizes and complexity. ConcourseEXP

enclosures and low-voltage modules have been designed to

provide seamless integration with MAXSYS control

panels and modules.

H O M E A U T O M A T I O N

Imagine a security system that controls home lighting automatically. With MAXSYS control panels lights can

be programmed to automatically turn on and off according to a daily, weekend or monthly schedule. These

tasks can be controlled by turning any touch-tone phone into a fully functional keypad that can be used to

monitor and control a security system from home or from anywhere in the world.

D L S 2 0 0 2 S A S Y S T E M A D M I N I S T R A T O R

S O F T W A R E

The DLS2002SA System Administrator software is a perfect solution for large or multi-location business

applications using the MAXSYS control panel. The software is simple to use and gives users the ability to view

and change codes, access cards and schedules, as well as view system status, arm/disarm partitions, and view,

sort and print the event buffer. The software can be found in the Products area of the DSC website under the

password-protected software section.

(11)

M A X S Y S

®

I N T E G R A T E D S Y S T E M S T E C H N O L O G Y

A D D R E S S A B L E E X P A N S I O N

S E R I A L I N T E R F A C E

I N T R U S I O N

A M B - 3 0 0 A D D R E S S A B L E P A S S I V E I N F R A R E D D E T E C T O R A M A - 1 0 0 A D D R E S S A B L E G L A S S B R E A K D E T E C T O R A M B - 5 0 0 A D D R E S S A B L E C E I L I N G - M O U N T P A S S I V E I N F R A R E D D E T E C T O R A M B - 6 0 0 A D D R E S S A B L E P E T - I M M U N E P A S S I V E I N F R A R E D D E T E C T O R F S B - 2 1 0 S E R I E S A D D R E S S A B L E P H O T O E L E C T R I C S M O K E D E T E C T O R S A M P - 7 0 0 / A M P - 7 0 1 A M P - 7 0 2 / A M P - 7 0 4 A D D R E S S A B L E C O N T A C T M O D U L E S A M X - 4 0 0 L O O P R E P E A T E R / I S O L A T O R M O D U L E A M L - 7 7 0 L O O P I S O L A T O R M O D U L E

A L T E R N A T E

C O M M U N I C A T I O N S

T - L I N KTM N E T W O R K A L A R M C O M M U N I C A T O R T - L I N KTM T L 2 5 0 I N T E R N E T A L A R M C O M M U N I C A T O R P C 4 4 0 1 D V D V A C S C O M M U N I C A T O R ( C A N A D A O N L Y ) 2 - W I R E A D D R E S S A B L E L O O P ( S ) W L S 9 2 5 L - 4 3 3 W I R E L E S S D O O R / W I N D O W C O N T A C T W L S 9 0 4 P L - 4 3 3 W I R E L E S S P A S S I V E I N F R A R E D D E T E C T O R W L S 9 1 2 L - 4 3 3 W I R E L E S S G L A S S B R E A K D E T E C T O R W S 4 9 1 6 W I R E L E S S P H O T O E L E C T R I C S M O K E D E T E C T O R W S 4 9 3 8 1 - B U T T O N P E R S O N A L P A N I C W S 4 9 5 9 1 2 - C H A N N E L , 5 - B U T T O N W I R E L E S S K E Y W S 4 9 4 9 2 - B U T T O N W I R E L E S S K E Y W S 4 9 3 9 4 - B U T T O N W I R E L E S S K E Y P C 4 1 6 4 - 4 3 3 W I R E L E S S R E C E I V E R 4 - W I R E C O M B U S P C 4 2 0 4 C X P O W E R S U P P L Y R E L A Y O U T P U T M O D U L E C O M B U S R E P E A T E R P C 4 1 0 8 / P C 4 1 1 6 8 / 1 6 H A R D W I R E Z O N E E X P A N D E R S L C D 4 5 0 1 P R O G R A M M A B L E -M E S S A G E L C D K E Y P A D P C 4 2 1 6 1 6 P R O G R A M M A B L E O U T P U T M O D U L E W I R E L E S S E X P A N S I O N L C D 4 5 2 1 P R O G R A M M A B L E F I R E - M E S S A G E L C D K E Y P A D P C 4 7 0 1 D U A L - L I N E D I A L E R M O D U L E P S 4 3 5 0 R E X T E R N A L B A T T E R Y C H A R G E R P C 4 7 0 2 B P D U A L - Z O N E B E L L P A N E L E S C O R TTM4 5 8 0 T E L E P H O N E I N T E R F A C E A N D A U T O M A T I O N C O N T R O L M O D U L E D L S 2 0 0 2 S A S Y S T E M A D M I N I S T R A T O R S O F T W A R E

W I N D O W S S O F T W A R E

L O C A L / R E M O T E C O N T R O L W I T H V O I C E P R O M P T T - R E XTM R E Q U E S T T O -E X I T D -E T -E C T O R R E A D E R S P O L A R I S , I o P R O XT M 2 6 - B I T W I E G A N D , K A N T E C H X S F T E C H N O L O G I E S P O L A R I S M A G S T R I P E

A C C E S S C O N T R O L

F I R E A L A R M

P C 4 6 3 2 / 4 6 6 4 3 2 / 6 4 P O I N T G R A P H I C A N N U N C I A T O R S

A U T O M A T I O N

P C 4 8 2 0 2 - R E A D E R A C C E S S C O N T R O L M O D U L E F S A - 2 1 0 / 4 1 0 S E R I E S 2 / 4 - W I R E P H O T O E L E C T R I C S M O K E D E T E C T O R S D L S 2 0 0 2 D O W N L O A D I N G S O F T W A R E P C 4 4 0 1 D A T A I N T E R F A C E M O D U L E S K Y R O U T E M A XTM W I R E L E S S T R A N S C E I V E R F O R M A X S Y S® W L S 9 1 4 - 4 3 3 W I R E L E S S P E T - I M M U N E P A S S I V E I N F R A R E D D E T E C T O R

(12)

Distributed by:

For product information www.dsc.com

Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. ©2005 2005•10 P / N 3 0 0 0 0 1 3 3 R 0 0 1 P ri n te d i n C a n a d a

M A X S Y S

A M E R I C A N L I S T I N G S

Category Description Applicable Standard

APAW Police station alarm units (commercial burglary) UL365, UL1635 AMCX Central station alarm units (commercial burglary) UL1610, UL1635

AOTX Local alarm units (commercial burglary) UL609, UL1635

NBSX Household burglar alarm units UL1023

UTOU Control units and accessories UL985

UOJZ Control units system (commercial fire) UL864

ALVY Access control system units UL294

E U R O P E A N L I S T I N G S

This product is in conformity with EMC directive 89/336EEC, R&TTE directive 1999/5/EC and low voltage directive 73/23/ECC based on results using the harmonized standards: CISPR Class B, EN50130-4, TBR21, EN60950-1.

A U S T R A L I A N L I S T I N G S

The product carries the A-Tick, Australian compliance mark, indicating that it meets safety and network integrity standards set by the ACA.

C H I N E S E L I S T I N G S

Certification under MII (Network Access License) and CCC (Burglar Alarm Systems) CCC Standard: General Specifications for Burglar-Alarm Control Units GB 12663-2001

MII standards: GB/T 15279-2002,YD/T 868-1996, YD/T 968-2002, YD/T 965-1998, YD/T 993-1998

C A N A D I A N L I S T I N G S

Description Applicable Standard

Central station fire alarm system units CAN/ULC-S527

Central monitoring station burglar alarm system units CAN/ULC-S302

Local alarm units (commercial burglary) CAN/ULC-S303

Household burglar alarm system units CAN/ULC-S310

Household fire warning system units CAN/ULC-S545

Access control system units UL294

References

Related documents

The paper concludes that, as far as Christian proponents of capitalism interpret biblical thought, it can be made compatible with a reformed Christian-influenced

With these utilities, you can manage your iR1024iF devices by tracking their document output (print/copy/scan/fax, by device, by department, by paper size, paper type,

Considering the data presented in the previous chapters, the research questions namely, ‘What teaching activities are teachers using through Facebook?’, ‘How do

 Emphasis on ‘What we cover’ is wrong – the homepage needs to respond to what people have in mind when they come to the site, it’s not about what we do;.  The

Motivated by the non-local mean approaches in image restoration, a non- local compressive sensing (NLCS) recovery method is proposed, which further reduces the sampling rate

There is a positive indirect effect of adaptive readiness (represented by CSE) on the adapting responses career plan- ning, career exploration, and occupational self-ef ficacy and

Combustion characteristics investigated were ignition time, burning time, calorific values, burning rate, specific fuel consumption, fuel efficiency and water boiling time.. The

The staggered adjustment of the redemption rates to changes in the market value of the property held by the fund also enabled open-end real estate funds to offer an