CertoLog & CertoPID HIGH-RES TOUCH SCREEN DATA STORED ON CLOUD PLATFORM EASY SETUP. Programmable data loggers and PID controllers with cloud access

N/A
N/A
Protected

Academic year: 2021

Share "CertoLog & CertoPID HIGH-RES TOUCH SCREEN DATA STORED ON CLOUD PLATFORM EASY SETUP. Programmable data loggers and PID controllers with cloud access"

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

HIGH-RES

TOUCH SCREEN

DATA STORED ON

CLOUD PLATFORM

EASY SETUP

CertoLog

& CertoPID

Programmable data loggers

and PID controllers with

cloud access

(2)

CertoLog

CertoLog Touch

CertoLog Touch Industrial

SET CertoLog Touch + PT 100 sensor SET CertoLog Touch Industrial + PT 100 sensor

Printer

PT 100 port female plug (emtpy) PT 100 Sensor

USB cable PC Software

Temperature (PT100) data logger. High precision measurement electronics. Cloud connected for easy data handling and storage. Ports: PT 100, USB, RS 232 for printer. Includes power cable.

Same, but with Industrial grade rugged tablet controller (waterproof). Capacitative touch screen.

With PT 100 sensor (Cable length 100cm. Silicone cable. Submersible probe).

Receipt printer. Thermotransfer.

Plug for soldering a PT 100 sensor. 3 or 4 wire.

PT 100 sensor with cable and plug. Submersion head. Other heads on request. 200cm silicone cable.

USB A to USB B cable. Connects CertoLog to a PC. For data display and storage on a windows PC.

8510313 8510315 8510314 8510316 1300154 1300224 8510317 1300196 8510318

CertoCloud

The easy to use cloud platform

• Data storage

• Data visualisation

• User management

• Alarm messages

• API for LIMS

integration

MODELS

ACCESSOIRES

ART. NR.

ART. NR.

DESCRIPTION

DESCRIPTION

3 month use

included with

purchase

DATA LOGGER WITH

REVOLUTIONARY INTERFACE

AND CLOUD CONNECTION

(3)

CertoPID LCD

CertoPID Touch

CertoPID Touch Industrial

SET CertoPID LCD + PT 100 sensor SET CertoPID Touch + PT 100 sensor

SET CertoPID Touch Industrial + PT 100 sensor

Printer

PT 100 port female plug (emtpy) PT 100 Sensor

USB cable

PC Software Basic Version PC Software

Professional Version

Programmable PID Controller with solid state relay (SSR), max 2000 W. High precision measurement electronics. Basic version of PC Software (data display and storage) included. Simple programms (1 temperature, 1 time) and endless programs can entered via the controller. Professional Version of PC Software necessary for programms with multiple temperature and time steps, ports: PT 100, USB, RS 232 for printer, power out max 2000 W. Includes power cable and power connection cable with high heat plug C15A acc. to IEC 60320-1. Same as above with tablet PC Controller. Cloud connected for easy data handling and storage. Complex programs can be entered via tablet controller (no addtional software required).

Same as above, but with Industrial grade rugged tablet controller (waterproof). Capacitative touch screen.

As above, but with PT 100 sensor (cable length 100 cm, silicone cable, submersible probe).

Receipt printer. Thermotransfer.

Plug for soldering a PT 100 sensor. 3 or 4 wire. PT 100 sensor with cable and plug. Submersion head. Other heads on request. 200cm silicone cable. USB A to USB B cable. Connects CertoLog to a PC. For data display and storage on a windows PC.

For data display and storage on a windows PC. Addtionally complex programs (multiple time and temperature steps) can be entered. Only needed for CertoPID LCD. 8510319 8510320 8510321 8510322 8510323 8510324 1300154 1300224 8510317 1300196 8510318 8510318

MODELS

ACCESSOIRES

ART. NR.

ART. NR.

DESCRIPTION

DESCRIPTION

CertoPID

CertoCloud

The easy to use cloud platform

3 month use

included with

purchase

PROGRAMMABLE POWER

CONTROLLER (PID/SSR) AND

CLOUD ACCESS

• Data storage

• Data visualisation

• User management

• Alarm messages

• API for LIMS

(4)

EASY DATA ACCESS AND STORAGE.

ONLINE DEVICE MANAGEMENT.

Secure Connection

• SSL encryption • Secure server • 100 % data privacy

Customization

• Custom reports • Direct printing

• Freely definable data formats

Email Notifications

• Alarms • Cycle complete

• Process data

User Management

• Individual accounts • Accounts linked to devices

Multi Device Management

• Combine all devices in one account • Create programs

• Disseminate programs to all devices

Long Term

Data Storage

• All data stored for 10 years to

fulfil documentation requirements • Secure backup

CertoCloud

(5)

THE USER INTERFACE WITH

ON-SCREEN TRAINING.

CertoTouch

Define custom programs

• With a simple interface you can program multi-step processes of temperature and time. E.g. 20 minutes at 110° C, then 3 hours at 120° C and then 1 hours at 80° C. • Long term cycles possible. Programming can be done in minutes, hours and days. • Program is graphically displayed.

• Programs can be named.

• One-click solution to program a fractioned venting process.

Choose program

• All programs are displayed as icons with name and key data. • Programs can be added an deleted.

• Full list of steps of each programm can be displayed.

Watch step-by-step video instructions

• All usage steps are explained in videos, e.g. when used as an autoclave the steps to load the unit are explained.

• No more need to train staff – the unit explains everything itself. • Videos can be skipped once staff is proficient in using the equipment.

Show status of running programs

• Current step of program is displayed. • Current data displayed.

• Time passed and remaining is displayed.

Scroll through protocol history

• Protocols are stored on the device.

• Target temperature and actual temperature are graphically displayed and accessible in numerical format.

(6)

TECHNICAL DETAILS

CONTACT

Art. Nr.

Interface Panel size

PC Software

Basic Version

PC Software

Professional Version

Audio

Connectivity

No. of programms

Max steps / program

Outputs

Max output

Alarmtypes

Supply voltage

Input type

Connector

Art. Nr.

PC Software

functionality

CertoPID LCD

8510319

4x20 LCD

Included

Included

Buzzer

USB, RS232

7

30

Power mains with

ground

2000 W

Sensor failure,

process failure

Basic Version

8510318

Live monitoring,

Protocoll management,

Data visualisation

CertoPID Touch

8510320

7 inch touch screen,

IPS, high res,

capacitative

Not included

Not included

Loudspeaker

USB, RS232,

Bluetooth, WiFi

unlimited

30

Power mains with

ground

2000 W

Sensor failure,

process failure

Professional version

8500210

Live monitoring,

Protocoll management,

Data visualisation,

Programm creation,

Programm management

220-240V 50/60 Hz

Resistance (PT100), 3 or 4 wire

CertoClav connector

CertoPID Touch

industrial

8510321

7 inch touch screen,

high res, capacitative,

industrial grade

(IP65)

Not included

Not included

Loudspeaker

USB, RS232,

Bluetooth, WiFi

unlimited

30

Power mains with

ground

2000 W

Sensor failure,

process failure

CertoLog Touch

8510313

7 inch touch screen,

high res,

capacitative

Not included

Not applicable

Loudspeaker

USB, RS232,

Bluetooth, WiFi

Sensor failure

CertoLog Touch

Industrial

8510315

7 inch touch screen,

high res, capacitative,

industrial grade

(IP65)

Not included

Not applicable

Loudspeaker

USB, RS232,

Bluetooth, WiFi

Sensor failure

Certoclav Sterilizer GmbH

Georg Grinninger-Str. 37

A-4050 Traun

Phone: +43 (0)7229 689

www.certoclav.com

Orders, technical customer service, custom-manufacture, dealer verification:

Christina Bokesch, Phone: +43 (0)7229 689 26, Fax: +43 (0)7229 74 141

Email: [email protected]

Product Manager: Klaus David, Phone: +43 (0)7229 689 28, Email: [email protected]

Operating instructions, technical information and operation videos: www.certoclav.com.

References

Related documents

The wage effect of profit taxes acts along the intensive margin and generates a 12 percent drop in average size for both young and mature firms.. The effects along the extensive

From an ecological and evolutionary perspective, these competing taxa inhabit an unpredictable and fluctuating anthropogenic environment similar to that experienced by many

• Verify correct outputs for expected Alarm Mode and initial “Run Mode” • Set Input true (on). Any unexpected responses must be recorded and corrected before the program can

As and when a section of the Network is accepted, or deemed to be accepted (as the case may be), pursuant to clause 14 of the Agreement, the relevant percentage of the Services

This document describes the recommended Best Practice, Standards & Contact information for Minnesota Hospitals and Regions to assist in planning for

By considering the fact that the participants were allowed to choose more than one option in answering the questions, attitudes of surveyed physicians about the

Features MPPU Cross-flow Peltric.. It has several sub-components described below. b) Turbines: The turbine converts energy from the falling water into rotating shaft power. c)