Oil pump
PO
Oi
l p
um
p
PO
Oil pump and accessories
SUNTEC ... CSB.160
DANFOSS ... CSB.172
DELTA ... CSB.178
ECKERLE ... CSB.179
RIELLO ... CSB.181
SAFAG ... CSB.182
SP ... CSB.183
Solenoid valve ... CSB.183
Transfer pump ... CSB.185
Suctionpump ... CSB.190
Carburettor ... CSB.194
CSB
SUNTEC pump
Solenoid valve
Transfer pump
GPS-10
oil suction
transfer unit
Carburettor
YOU SEARCH A PUMP
You must know :•Burner mark •Burner type
•Burner number •Burner manufacturing year But many burner manufacturers use different pumps on the same burner. So you can note :
The engraved pump reference
But if it is not possible to read this information you must note : •Ø of shaft •shaft rotation (with shaft in front of you) •Ø of hub •outlet nozzle side (with shaft in front of you) •with fl ange •with solenoid valve
•or without fl ange •or without solenoid valve •nozzle capacity
DISTRIBUTED BY DIFF
SUNTEC
AU 47 revision 6
P
Description Ref
SUNTEC Suitcase with 2 AU 47 pumps
301992
Contains 2 AU pumps and accessories, allows to repair the majority of burner oil pump or kerosene pump
with or without solenoid valve, with right or left rotation, with right or left outlet nozzle position, with or without flange can be repaired.
Type tr/mn and 10 barsFlow l/h to 2800 Ø=ShaftM=Hub Rotation nozzle sideOutlet Pressurebar Ref
AU 47 L 9853 6P0500 40 M 32 x Ø8 ➞ 4/25
301870
AU 47 R 9852 6P0500 40 M 32 x Ø8 ➞ ➞ 4/25
301871
In this suitcase you have also spare parts and accessories for maintenance.
Suitcase components :
✓1 AU 47 L pump (left rotation, left or right outlet nozzle position). Diff ref 301870
✓1 AU 47 R pump (right rotation, left or right outlet nozzle position). Diff ref 301871
✓2 connectorsDiff ref 803030
✓2 strainers Diff ref 301561
✓1 coil 220-240V, 50/60 Hz Diff ref 301478
✓2 cover gaskets Diff ref 301434
✓1 changing kit AU pump to AE pump Diff ref 301589
✓1 adapter hub Ø32 / 54 Diff ref 301310
✓1 flange allows to obtain a pump with fixing flange and hub Ø54 Diff ref 301301
✓1 TEFEM 1/8-1/8 Diff (from connection) ref 602510
✓1 Extension shaft pupm DN8/11,1 Diff ref 601130
Universal replacement pump
2 pumps replace
51 Suntec models
24 Delta Fuel Master models
and 105 Danfoss models
Suntec proposes a new pump specially designed for maintenance market : The AU 47 revision 6 pump
Technical features :
✓Better stock control
✓Quick and easy installation
✓Outlet nozzle on the right or on the left
✓Normally closed solenoid valve
✓Same performance and quality as SUNTEC type “A“
AU revision 6 pumps replace more pumps than AU revision 2.
The photographic model is an «AU 47L» (left rotation - Outlet nozzle on the right or on the left, in front of the shaft)
So, the suitcase with 2 AU47 pumps (left and right rotation), 1 adaptor hub, 1 flange and 1 changing AU to AE pump kit can replace 95% of low flow pumps.
AU 47 R 9852 6P 0500 Pump Diff ref 301871 AU 47 L 9851 6P 0500 Pump Diff ref 301870
IMPORTANT
Note : The new AU 47 revision 6 pump allows a direct sealing at the bottom of the inlet and return ports. It is not possible with AU 47 revision 2.
All these accessories are also separately sold for the suitcase restocking
Oil pump
CSB.160
Oi
l p
um
p
PO
A2L Range with 2 SOLENOID VALVES
The SUNTEC A2L oil pump has two nozzle outlets. It incorporates two blocking solenoid valves with in-line cut-off function, one for each nozzle outlet.
Application : ✓ Domestic Fuel oil ✓ 2 nozzle outlets ✓ 2 blocking solenoid valves with in-line cut-off function ✓ 1 regulator for both nozzle lines
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet nozzle
side Pressure Ref
A2L 65 A 9708 2P 0500 82* M32x8 - ➞ ➞ 8/15
301892
A2L 65 B 9707 2P 0500 82* M32x8 - ➞ ➞ 8/15301893
A2L 65 C 9704 2P 0500 82* M32x8 (1) ➞ 7/14301894
A2L 65 D 9703 2P 0500 82* M32x8 (2) ➞ 8/15301930
A2L 75 C 9701 2P 0500 110* M32x8 (1) ➞ 7/14301895
A2L 95 B 9711 2P 0500 132* M32x8 - ➞ ➞ 9/25301896
A2L 95 D 9702 2P 0500 132* M32x8 (2) ➞ 8/15301931
(1) Kerosene - (2) Inlet and Return M16 - * With air jack outlet
AL Range with SOLENOID VALVE
The SUNTEC AL oil pump incorporates a blocking solenoid valve with in-line cut-off function. Bleeding in two-pipe operation is auto-matic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system.. Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet nozzle
side Pressure Ref
AL 30 C 9537 4P 0500 40 M 32 x 8 - 8/15
301946
AL 35 A 9526 2P 0500 40 M 32 x 8 - ➞ ➞ 8/15301949
AL 35 A 9570 2P 0500 40* M 32 x 8 - ➞ ➞ 8/15301958
AL 35 A 9596 2P 0100 40* M 32 x 8 (5) ➞ ➞ 8/15301936
AL 35 A 9596 2P 0500 40* M 32 x 8 - ➞ ➞ 8/15301869
AL 35 B 9580 2P 0500 40* M 32 x 8 - ➞ 8/15301956
AL 35 C 9521 2P 0100 40 M 32 x 8 (5) 4/18301938
AL 35 C 9521 2P 0500 or AL 35C 9519 6P 0500 40 M 32 x 8 - 4/18301873
AL 35 C 9528 2P 0500 40 M 32 x 8 - 8/15301957
AL 35 C 9540 2P 0500 40 M 32 x 8 (1) 8/15301950
AL 35 C 9545 1P 0500R 40 M 32 x 8 (1) 8/15 see 301950 AL 35 C 9578 2P 0500R 40* M 32 x 8 - 8/15 see 301987 AL 35 D 9529 2P 0200 40 M 32 x 8 (2) ➞ 8/15301959
AL 35 D 9529 2P 0500 40 M 32 x 8 - ➞ 8/15301939
AL 35 D 9595 2P 0500 40 M 32 x 8 (6) ➞ 8/15 see 301939 AL 55 C 9598 2P 0500 60 M 32 x 8 (4)(6) 10/25 see 301986 AL 65 B 9532 2P 0500 82 M 32 x 8 - ➞ 4/18301877
AL 65 C 9410 2P 0500 82* B 54 x 8 - 4/18301879
AL 65 C 9525 2P 0500 82 M 32 x 8 (3) 8/15301980
AL 65 C 9588 2P 0500 82* M 32 x 8 - 8/15301981
AL 65 C 9589 2P 0500 82 M 32 x 8 - 8/15301982
AL 75 B 9539 2P 0500 110 M 32 x 8 - ➞ 8/15301880
AL 75 C 9411 2P 0500 110* B 54 x 8 - 4/18301881
AL 95 C 9412 2P 0500 132* B 54 x 8 - 10/20301984
AL 95 C 9414 2P 0500 132* B 54 x 8 (7) 10/20301882
AL 65 C 9525 2P 0500 82 M 32 x 8 (5) 8/15301980
AL 65 C 9588 2P 0500 82* M 32 x 8 - 8/15301981
AL 65 C 9589 2P 0500 82 M 32 x 8 - 8/15301982
AL 75 B 9539 2P 0500 110 M 32 x 8 - ➞ 8/15301880
AL 75 C 9411 2P 0500 110* B 54 x 8 - 4/18301881
AL 75 C 9534 2P 0500 110 M 32 x 8 (5)(6) 8/15301983
AL 95 C 9412 2P 0500 132* B 54 x 8 - 10/20301984
AL 95 C 9414 2P 0500 132* B 54 x 8 (10) 10/20301882
(1) Inlet and Return.1/8" - (2) Coil 24 VAC - (3) Conical nipple Ø4 - (4) Kerosene - (5) Coil 110VAC - (6) Adjusting screw pressure on the nozzle side. (7) Shaft with 2 flat surfaces *With outlet air jack.
ALE Range with SOLENOID VALVE
The SUNTEC ALE oil pump incorporates a blocking solenoid valve fitted with a built-in return valve ensuring an in-line cut-off function and a nozzle line pressure relief. Bleeding in two pipe operation is automatic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system. Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet nozzle
side Pressure Ref
ALE 35 A 9325 2P 0500 40 M 32 x 8 - ➞ ➞ 8/15
301883
ALE 35 C 9322 2P 0500 40 M 32 x 8 - 10/25301886
ALE 35 C 9324 2P 0500 40 M 32 x 8 - 4/18301888
ALE 35 C 9327 2P 0500 40* M 32 x 8 - 8/15301889
ALE 35 C 9328 2P 0500 40* M 32 x 8 (1) 8/15301890
ALE 35 C 9329 6P 0500 40 M 32 x 8 (2)(3) 12/25301985
ALE 35 C 9334 2P 0500* 40 M 32 x 8 (4) 8/15301987
ALE 55 C 9330 2P 0500 58 M 32 x 8 (2)(3) 12/25301986
(1) Kerosene - (2) Adjusting pressure screw on the nozzle side - (3) Shaft with 2 flat surfaces (4) Direct sealing Inlet and Return *With outlet air jack
Oil pump
Oi
l p
um
p
PO
AR Range with SOLENOID VALVE
The SUNTEC AR oil pump incorporates a blocking solenoid valve with in-line cut-off function and a second regulator for nozzle return pipe. Bleeding in two pipe operation is automatic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system
Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet nozzle
side Pressure Ref
AR 65 A9801 2P 0500 75 M 32 x 8 ➞ ➞ 12/25 5/15
301897
AN Range without SOLENOID VALVE
The SUNTEC AN oil pump is the basic model incoporating pressure regulation valve with cut-off.
Information AN
The pumps in grey line can be used for the other pump replacements with adding flange or adapter hub. In this way you can decrease your stock and increase your possibilities of repair and maintenance.
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
AN 47 A 7216 3P 40 B 54 x 8 (2)(4) ➞ ➞ 7/14
301041
AN 47 A 7283 2M 40 B 54 x 8 (1)(3)(4) ➞ ➞ 7/14 see 301041 AN 47 B 7217 3P 40* B 54 x 8 (2)(4) ➞ 7/14301732
AN 47 C 7218 3P 40 B 54 x 8 (2)(4) 7/14301734
AN 47 D 7219 3P 40 B 54 x 8 (2)(4) ➞ 7/14301047
AN 47 A 1326 1P 40 M 32 x 8 - ➞ ➞ 7/14301731
AN 47 A 7326 3P 40* M 32 x 8 - ➞ ➞ 7/14301733
AN 47 A 7226 3P 40 M 54 x 8 (2) ➞ ➞ 7/14301042
AN 47 B 1395 1P 40 M 32 x 8 - ➞ 7/14301049
AN 47 B 7227 3P 40* M 54 x 8 (2) ➞ 7/14301043
AN 47 B 7327 3P 40* M 32 x 8 - ➞ 7/14301044
AN 47 C 1342 1P 40 M 32 x 8 - 7/14301750
AN 47 C 7228 3P 40 M 54 x 8 (2) 7/14301045
AN 47 C 7247 3M 40* B 54 x 8 (1)(6)(4) 7/12301737
AN 47 C 7328 3P 40* M 32 x 8 (4) 7/14301738
AN 47 C 7342 3P 40* M 32 x 8 - 7/14301739
AN 47 D 1339 1P 40 M 32 x 8 - ➞ 7/14301749
AN 47 D 7229 3P 40 M 54 x 8 (2) ➞ 7/14301048
AN 47 D 7329 3P 40 M 32 x 8 (2) ➞ 7/14301749
AN 57 A 7351 3P 58* M 32 x 8 - ➞ ➞ 7/14301742
AN 57 B 1330 1P 58 M 32 x 8 - ➞ 10/20301054
AN 57 C 7282 3P 58* B 54 x 8 (4) 7/14301743
AN 67 A 7238 3P 82* B 54 x 8 (4) ➞ ➞ 10/20301071
AN 67 A 7345 3P 82* M 32 x 8 (4) ➞ ➞ 10/20301076
AN 67 B 1335 1P 82 M 32 x 8 - ➞ 10/20301074
AN 67 B 7251 3P 82* B 54 x 8 (4) ➞ 10/20301073
AN 67 B 7287 3P 82* M 54 x 8 - ➞ 10/20301064
AN 67 C 1336 1P 82 M 32 x 8 (4) 7/14301065
AN 67 C 1338 1P 82 M 32 x 8 (6)(7) 7/12301746
AN 67 C 7233 3P 82* B 54 x 8 (4) 10/20301075
AN 67 C 7242 3P 82* M 54 x 8 - 10/20301066
AN 67 D 7252 3P 82* B 54 x 8 (4) 10/20301077
AN 77 A 7255 2P 112* M 54 x 8 - ➞ ➞ 10/20301904
AN 77 A 7256 2P 112* B 54 x 8 - ➞ ➞ 10/20301752
AN 77 C 7235 2P 112* B 54 x 8 (4) 10/20301905
AN 77 C 7275 2P 112* M 54 x 8 - 10/20301756
AN 77 C 7341 2P 112* M 32 x 8 - 10/20301906
AN 97 A 7391 2P 132* M 32 x 8 - ➞ ➞ 10/20301758
AN 97 C 7257 2P 132* B 54 x 8 (4) 10/20301920
AN 67 D 7252 3P 82* B 54 x 8 (4) 10/20301077
AN 77 A 7255 2P 112* M 54 x 8 - ➞ ➞ 10/20301904
AN 77 A 7256 2P 112* B 54 x 8 - ➞ ➞ 10/20301752
AN 77 A 7266 2M 112* B 54 x 8 (1)(4) ➞ ➞ 10/15301753
AN 77 A 7295 2P 112* M 54 x 8 (9) ➞ ➞ 10/20301754
AN 77 A 7346 2P 112* M 54 x 8 - ➞ ➞ 10/20301796
AN 77 C 7235 2P 112* B 54 x 8 (4) 10/20301905
AN 77 C 7275 2P 112* M 54 x 8 - 10/20301756
AN 77 C 7341 2P 112* M 32 x 8 - 10/20301906
AN 77 D 7358 2P 112* M 32 x 8 - ➞ 10/20301757
AN 97 A 7391 2P 132* M 32 x 8 - ➞ ➞ 10/20301758
AN 97 C 7257 2P 132* B 54 x 8 (4) 10/20301920
(1) One-pipe pump - (2) Replaced by AN Kit - (3) Bleeding screw 1/4NPTF on the regulator side - (4) Long outlet nozzle (5) Shaft with 2 flat surfaces - (6) Kerosene - (7) Motor speed 3450tr/min - * with air jack outlet
Oil pump
CSB.162
Oi
l p
um
p
PO
ASSEMBLY
tanks to the flange, a pump with a 32mm hub Ø can be transformed into a flange pump (92mm) and a 54mm hub Ø.
✓Slide the flange on the hub pump with flat surface against pump surface
✓Screw the flange.
NOTE The flange bosses gives a hub Ø 54 mm
Types of Pumps replaced with a current pump and this flange
Current pump Ref + Adapter hub 32/54 + Flange hub 54 Replaced pump Replaced pump Ref AN 47 A 1326 301731 + 301310 AN 47 A 1326AN 47 A 7226 301731301042 + 301301 AN 47 A 7216 301041 AN 47 B 7327 301044 + 301310 AN 47 B 7327AN 47 B 7227 301044301043 + 301301 AN 47 B 7217 301732 AN 47 D 1339 301749 + 301310 AN 47 D 1339AN 47 D 7229 301749301048 + 301301 AN 47 D 7219 301047 AN 47 C 1342 301750 AN 47 C 1342 301750 AN 47 C 1342 301750 + 301310 AN 47 C 7228 301045 + 301301 AN 47 C 7218 301734
AE Range without SOLENOID VALVE
The SUNTEC AE oil pump is the basic model incorporating a pressure regulating valve. It does not have a cut-off features, to purge air, gas through the nozzle line.
Information AE
The AE 87 range is replaced by the AE77 range.
The flange 301301 and the adapter hub 301310 can be used with this range of AE pump
Type 2800 tr/mn Flow l/h to and 10 bars M=Hub B=Flange Ø=Shaft
Featu-res Rotation nozzle side PressureOutlet Ref
AE 35 C 9850 2P 40 M 32 x 8 (1) 4/18
301759
AE 45 C 1360 1P 40 M 32 x 8 - 7/14301801
AE 45 C 1370 1M 40 M 32 x 8 (2)(4) 7/14301802
AE 47 A 1384 1M 40 M 32 x 8 (4) ➞ ➞ 7/14301800
AE 47 A 1384 1P 40 M 32 x 8 - ➞ ➞ 7/14301761
AE 47 A 7384 3M 40* M 32 x 8 (4) ➞ ➞ 7/14301762
AE 47 B 1366 1P 40 M 32 x 8 - ➞ 7/14301805
AE 47 B 7267 3P 40* M 54 x 8 - ➞ 7/14301763
AE 47 C 1386 1P 40 M 32 x 8 - 2/12301803
AE 47 C 1387 1P 40 M 32 x 8 - 7/14301799
AE 47 C 1394 1P 40 M 32 x 8 (5) 3/15301764
AE 47 C 1397 1P 40 M 32 x 8 - 10/20 see 301799 AE 47 C 7368 3P 40* M 32 x 8 - 5/12301804
AE 47 C 1393 1M 40 M 32 x 8 (4)(3) 0,5/3301797
AE 47 D 1378 1M 40 M 32 x 8 (4) ➞ 7/14301768
AE 47 D 1385 1P 40 M 32 x 8 - ➞ 5/20301798
AE 57 B 1364 1M 50 M 32 x 8 (4) ➞ 10/20301769
AE 57 C 7373 3P 50* M 32 x 8 (1) 8/28301806
AE 67 C 7285 3P 80* B 54 x 8 (3) 7/14301812
AE 67 C 7361 3P 80* M 32 x 8 (1) 8/28301810
AE 67 D 7278 3P 80* B 54 x 8 - ➞ 7/14301811
AE 77 B 7291 3P 112* M 54 x 8 - ➞ 8/28301774
AE 77 C 7270 2P 112* B 54 x 8 (3)(1) 10/28301832
AE 97 C 7296 3P 132* B 54 x 8 (3) 8/28301794
AE 97 C 7297 3P 132* B 54 x 8 (3)(6) 7/12301795
AE 97 C 7390 2P 132* M 32 x 8 (3) 0,5/3301839
AE 97 C 7390 2M 132* M 32 x 8 (4)(3) 0,5/3301838
AE 97 D 7355 2P 132* M 32 x 8 - ➞ 2/12301807
AE 77 C 7270 2P 112* B 54 x 8 (3)(1) 10/28301832
AE 77 C 7380 2P 112* B 32 x 8 (1) 10/20301833
AE 97 C 7296 3P 132* B 54 x 8 (3) 8/28301794
AE 97 C 7297 3P 132* B 54 x 8 (3)(6) 7/12301795
AE 97 C 7390 2P 132* M 32 x 8 (3) 0,5/3301839
AE 97 C 7390 2M 132* M 32 x 8 (4)(3) 0,5/3301838
AE 97 D 7355 2P 132* M 32 x 8 - ➞ 2/12301807
(1) Pressure gauge port on the top - (2) Inlet 1/8" fem. Return 1/8" male - (3) Long outlet nozzle - (4) One-pipe pump (5) Shaft with 2 flat surfaces - (6) Kerosene - *with air jack outlet
Oil pump
Oi
l p
um
p
PO
AS Range with SOLENOID VALVE
The SUNTEC AS oil pump has a built in solenoid valve which controls the regulator cut-off valve giving fast cut-off and cut-on func-tion independent of the rotafunc-tional speed.
Information AS
The pumps in grey line can be used for the other pump replacements with adding flange or adapter hub. In this way you can decrease your stock and increase your possibilities of repair and maintenance.
Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
AS 47 A 1536 1P 0500 40 M 32 x 8 - ➞ ➞ 7/14
301082
AS 47 A 1536 6P 0500 40 M 32 x 8 (11) ➞ ➞ 7/14301925
AS 47 A 1564 1P 0500 40 M 32 x 8 (4) ➞ ➞ 7/12301808
AS 47 A 1588 1P 0500 40 M 32 x 8 (4)(10) ➞ ➞ 7/12 see 301815 AS 47 A 1590 1P 0200 40 M 32 x 8 (11) ➞ ➞ 7/14301814
AS 47 A 1602 6P 0500 40 M 32 x 8 (4)(10) ➞ ➞ 7/12301815
AS 47 A 7432 3P 0500 40 B 54 x 8 (5)(2)(8) ➞ ➞ 7/14301081
AS 47 A 7436 3P 0500 40* M 54 x 8 - ➞ ➞ 7/14301816
AS 47 A 7465 2M 0500 40* B 54 x 8 (8)(13)(2)(4) ➞ ➞ 7/12301818
AS 47 A 7536 3P 0500 40* M 32 x 8 - ➞ ➞ 7/14301819
AS 47 A 7564 3P 0500 40* M 32 x 8 (4) ➞ ➞ 7/12301850
AS 47 A 7509 3P 0500 40* M 32 x 8 (1)(7)(8) ➞ 7/16301852
AS 47 B 1537 6P 0500 40 M 32 x 8 - ➞ 7/14301084
AS 47 B 1537 1P 0260 40 M 32 x 8 (11) ➞ 7/14301928
AS 47 B 1537 1P 0310 40 M 32 x 8 (15) ➞ 7/14301929
AS 47 B 1605 1P 0500 40 M 32 x 8 (10) ➞ 7/14301822
AS 47 C 1538 6P 0500 40 M 32 x 8 - 7/14301086
AS 47 C 1538 (110V) 40 M 32 x 8 (3) 7/14301090
AS 47 C 1538 1P 0200 40 M 32 x 8 (11) 7/14301932
AS 47 C 1554 1P 0500 40 M 32 x 8 (4)(9) 7/12301846
AS 47 C 1569 1P 0500 40 M 32 x 8 - 7/14 see 301086 AS 47 C 1578 1P 0500 40 M 32 x 8 - 7/25 see 301829 AS 47 C 1581 1P 0500 40 M 32 x 8 (4) 7/12 see 301846 AS 47 C 1582 1P 0500 40 M 32 x 8 (4)(14) 7/12301826
AS 47 C 1587 1P 0500 40 M 32 x 8 (4)(1) 7/25301827
AS 47 C 1601 1P 0500 40 M 32 x 8 - 7/14 see 301086 AS 47 C 1603 3P 0500 40 M 32 x 8 - 7/14 see 301086 AS 47 C 1604 6P 0500 40 M 32 x 8 (10) 7/25301829
AS 47 C 1607 1P 0500 40 M 32 x 8 (9)(10) 7/12 see 301846 AS 47 C 7434 3P 0500 40 B 54 x 8 (5)(2)(8) 7/14301841
AS 47 C 7434 3P 0260 40* B 54 x 8 (11)(2)(8) 7/14301933
AS 47 C 7438 3P 0500 40 M 54 x 8 (6) 7/14301843
AS 47 C 7444 3P 0500 40 B 54 x 8 (5)(2) 7/14301085
AS 47 C 7451 3M 0500 40* B 54 x 8 (8)(12)(2)(4) 7/12301848
AS 47 C 7461 3P 0500 40* B 54 x 8 (2)(8) 10/20301845
AS 47 C 1538 6P 0500 40 M 32 x 8 - 7/14301086
AS 47 C 7554 3P 0500 40* M 32 x 8 (4) 7/12 see 301846 AS 47 D 1539 1P 0500 40 M 32 x 8 - ➞ 7/14301088
AS 47 D 1550 1P 0500 40 M 32 x 8 - ➞ 7/25301083
AS 47 D 1557 1P 0500 40 M 32 x 8 (1) ➞ 7/22301849
AS 47 D 1562 1P 0500 40 M 32 x 8 (4) ➞ 7/12301836
AS 47 D 1586 1P 0500 40 M 32 x 8 (1)(4) ➞ 7/25301840
AS 47 D 1596 1P 0500 40 M 32 x 8 - ➞ -301079
AS 47 D 1596 + vis 40 M 32 x 8 - ➞ -406021
AS 47 D 1597 1M 0500 40 M 32 x 8 (4) ➞ 7/12301842
AS 47 D 1580 1P 0500 40 M 32 x 8 (7) ➞ 7/14301080
AS 47 D 7435 3P 0500 40 B 54 x 8 (5)(2)(8) ➞ 7/14301087
AS 47 D 7439 3P 0500 40 M 54 x 8 (5) ➞ 7/14301844
Oil pump
CSB.164
Oi
l p
um
p
PO
AS Range with SOLENOID VALVE
(continuation)Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
AS 57 A 7591 3P 0500 40* M 32 x 8 - ➞ ➞ 7/14
301855
AS 57 B 1585 1P 0500 40 M 32 x 8 - ➞ 7/14301856
AS 57 C 1544 1P 0500 58 M 32 x 8 - 7/14301091
AS 57 C 1583 1P 0500 58 M 32 x 8 (5) 7/12301858
AS 57 C 7441 3P 0500 58 B 54 x 8 (6)(3)(9) 7/14301093
AS 67 A 7463 3P 0500 82* B 54 x 8 (3) ➞ ➞ 10/15301865
AS 67 A 7466 3P 0500 82* B 54 x 8 (3)(9) ➞ ➞ 10/15301866
AS 67 B 1575 1P 0500 82 M 32 x 8 - ➞ 10/15301863
AS 67 B 7449 3P 0500 82* B 54 x 8 (3)(9) ➞ 10/15301868
AS 67 C 1570 1P 0500 82 M 32 x 8 - 10/15301862
AS 67 C 7446 3P 0500 82* M 54 x 8 (5) 10/14301860
AS 67 C 7456 3P 0500 82* B 54 x 8 (3)(9) 10/15301861
(1) Shaft with 2 flat surfaces
(2) Type with flange - (3) 110 VAC - (4) Kerosene type- (5) Replaced by AS kit - (6) Outlet nozzle with flare nipple (7) Inlet and return 1/8 - (8) Long outlet nozzle - (9) Adjusting pressure screw 4mm BTR - (10) Direct sealing inlet and return (11) 24 VAC - (13) Inlet 1/4NPTF on the regulator side - (12) One-pipe pump - (13) Inlet steel plug
(14) Pressure gauge port on the nozzle side - (15) 24 VDC - * With air jack outlet.
Changing KIT FROM AS pump to AN pump
ASSEMBLYCut-off fuel oil inlet and power supply too. Disconnect the coil.
✓Remove the coil "A"
✓Remove the plate "B"
✓Remove the coil tube "C"
✓Put the kit "D" on the pump
✓Put the plate "B" on the pump
✓Start the burner and check for leaks
Note : SUNTEC accepts no liability with consequences of wrong assembly or wrong use of this kit.
This kit can only be used for changing AS pump to AN pump.
Changing example :
AS 47 C 7536 to AN 47 A 7326 AS 47 C 7538 to AN 47 C 7342
Current pump Ref + Adapter hub 32/54 + Flange hub 54 Replaced pump Replaced pump ref AN 47 A 1536 301082 + 301301 AN 47 A 7536AN 47 A 7432 301082301081 AN 47 C 1538 301086 AN 47 C 7538 301086 + 301310 AN 47 C 7438 301843 + 301301 AN 47 C 7434 301841 + 301301 AN 47 C 7444 301085
AT Range with 2 SOLENOID VALVES
The SUNTEC AT2 oil pump features a two mode pressure operation and incorporates a blocking solenoid valve with in-line cut-off function. Switching between low and high modes is ensured by a second integral solenoid valve.
The SUNTEC AT3 oil pump incorporates in addition a pressure gauge on the cover for checking high pressure nozzle or pressure return in low pressure function. Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
AT2 45 A 9547 2P 0500 46* M 32 x 8 (2) ➞ ➞ 8/25
301132
AT2 45 C 9541 2P 0500 46* M 32 x 8 (2) 8/25301120
AT2 45 C 9563 2P 0500 46* M 32 x 8 (1)(2) 8/25301122
AT2 45 D 9538 4P 0500 46* M 32 x 8 - ➞ 8/25301005
AT2 45 D 9544 2P 0500 46* M 32 x 8 (2) ➞ 8/25301121
AT2 45 D 9555 2P 0500 46* M 32 x 8 (2) ➞ 8/25301121
AT2 55 C 9549 2P 0500 65* M 32 x 8 (2) 8/25301125
AT2 55 C 9572 2P 0500 65* M 32 x 8 (2)(4) 8/25301903
AT2 65 A 9577 2P 0500 87* M 32 x 8 (2) ➞ ➞ 8/25301126
AT2 65 B 9587 2P 0500 87* M 32 x 8 (2) ➞ 8/25301907
AT2 65 D 9582 2P 0500 87* M 32 x 8 (2)(5) ➞ 2/15301910
(1) Inlet and return 1/8" - Outlet nozzle with male nipple 1/8" for pipe Ø 4 - (2) Flow indication in high pressure function (3) Inlet and return M16 - (4) Proofed at 28 bars - (5) Kerosene - * With air jack outlet
Oil pump
Oi
l p
um
p
PO
AT Range with 2 SOLENOID VALVES
(continuation)The SUNTEC AT2 oil pump features a two mode pressure operation and incorporates a blocking solenoid valve with in-line cut-off function. Switching between low and high modes is ensured by a second integral solenoid valve.
The SUNTEC AT3 oil pump incorporates in addition a pressure gauge on the cover for checking high pressure nozzle or pressure return in low pressure function. Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
AT2 95 B 9592 2P 0500 132* M 32 x 8 (2) ➞ 8/25
301775
AT2 95 C 9585 2P 0500 132* M 32 x 8 (2)(3) 8/25301777
AT3 45 A 9559 2P 0500 46* M 32 x 8 (2) ➞ ➞ 8/25301133
AT3 45 C 9558 2P 0500 46* M 32 x 8 (2) 8/25301135
AT3 45 D 9546 2P 0500 46* M 32 x 8 (2) ➞ 8/25301130
AT3 45 B 9575 2P 0500 46* M 32 x 8 (2) ➞ 8/25301134
AT3 55 C 9550 2P 0500 65* M 32 x 8 (2) 8/25301131
AT3 55 D 9564 2P 0500 65* M 32 x 8 (2) ➞ 8/25301778
(1) Inlet and return 1/8" - Outlet nozzle with male nipple 1/8" for pipe Ø 4 - (2) Flow indication in high pressure function (3) Inlet and return M16 - (4) Proofed at 28 bars - (5) Kerosene - * With air jack outlet
AP Range with 2 MODE PRESSURE SOLENOID VALVES
Delivered without connector
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
AP 47 A 1593 1P 0500 40 M 32 x 8 (1)(2)(3) ➞ ➞ 3/28
301100
AP 47 B 7561 3P 0500 40* M 32 x 8 - ➞ 3/28301099
AP 47 C 7460 3P 0500 40* B 54 x 8 (2)(4) 3/28301097
AP 47 C 7556 3P 0500 40* M 32 x 8 - 3/28301098
AP 57 A 7549 3P 0500 58* M 32 x 8 - ➞ ➞ 3/28301095
AP 57 C 7545 3P 0500 58* M 32 x 8 - 3/28301092
AP 67 C 7559 3P 0500 82* M 32 x 8 - 5/28301109
AP2 45 C 9560 1P 0500 46* M 32 x 8 - 8/25301782
AP2 45 D 9566 1P 0500 46* M 32 x 8 - ➞ 4/25301941
AP2 65 B 9523 1P 0500 87* M 32 x 8 - ➞ 4/25301783
AP2 95 C 9590 1P 0500 132* M 32 x 8 - 8/25301943
AP3 45 C 9510 1P 0500 46* M 32 x 8 - 4/25301101
(1)Inlet/Return G18 - (2)Long outlet nozzle- (3)Special outlet nozzle plug - (4) Type with flange -* With air jack outlet.
The SUNTEC AP oil pump has a built-in solenoid valve which provides a two-mode pressure operation. AP2 and AP3 ranges are from the same technology as AT2 x AT3 ranges, but without in-line cut-off function.
D Range without SOLENOID VALVE
The SUNTEC D oil pump is specially adapted for heavy oil. This pump incorporates a pressure regulator without in-line cut-off function. For oil flow 45 to90 l/h (2850 tr/mn - 20 cSt - 20 bars) viscosity 2 to 200 cSt.
The new revision 3 of the range D incorporates an antiabrasion plate in the gear for more efficiency.
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation
Outlet
nozzle side Pressure Ref
D 45 B 7347 3P 54 M 32 x 8 (3) ➞ 10/28
301114
D 45 B 7388 3P 54 M 32 x 8 (8) ➞ 0,5/3301786
D 45 C 7281 3P 54 B 54 x 8 (4)(2)(5)(6) 10/28301119
D 47 A 7383 3P 54 M 32 x 8 (7)(8) ➞ ➞ 7/25301116
D 47 D 7352 3P 54 M 32 x 8 (7)(11) ➞ 10/28301787
D 57 C 7372 3P 72 M 32 x 8 (6)(9) 10/28301111
D 67 A 7276 3P 97 B 54 x 8 (2)(4)(5) ➞ ➞ 10/28301117
D 67 A 7280 3P 97 M 54 x 8 (1)(7)(10) ➞ ➞ 16/28301118
D 67 C 7284 3P 97 B 54 x 8 (1)(5)(8) 10/28301792
(1) Cover with hole for heater element (Type with in-line cut-off function) - (2) Cover vacuum gauge port G 1/4" on regulator side (3) Body vacuum gauge port G 1/8" on regulator side - (4) Long outlet nozzle - (5) Type with flange - (6) With air jack outlet on the top - (7) In-line cut-off function- (8) Cover vacuum gauge port G 1/8" on regulator side - (9) Cover vacuum gauge port G 1/8" on outlet nozzle side - (10) Inlet on cover (11) Inlet and return M14
Oil pump
CSB.166
Oi
l p
um
p
PO
J Range without SOLENOID VALVE
The SUNTEC J oil pump incorporates a pressure regulating valve with cut-off function except the J oil pump 1002. The J oil pump is
adapted for heavy oil 2,8 to 200 cSt. The J oil pumps range 1000 are built with conical threads. The J oil pump range 1000 and 1001 incorporate an in-line cut-off function. The J oil pump range 1002 are built without in-line cut-off function.
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation nozzle side PressureOutlet Ref
J3 CAB 1000 3P 90 B 54 x 11,11 (3) ➞ ➞ 7/14 see
301011
J3 CBB 1000 3P 90 B 54 x 11,11 (3) ➞ 7/14 see301012
J3 CCB 1000 3P 90 B 54 x 11,11 (3) 7/14 see301013
J3 CDB 1000 3P 90 B 54 x 11,11 (3) ➞ 7/14 see301014
J4 CAC 1000 5P 110 B 54 x 11,11 (3) ➞ ➞ 10/21301011
J4 CBC 1000 5P 110 B 54 x 11,11 (3) ➞ 10/21301012
J4 CCC 1000 5P 110 B 54 x 11,11 (3) 10/21301013
J4 CDC 1000 5P 110 B 54 x 11,11 (3) ➞ 10/21301014
J6 CAC 1000 5P 205 B 54 x 11,11 (1)(3) ➞ ➞ 10/21301021
J6 CAC 1002 5P 205 B 54 x 11,11 (1)(4)(3) ➞ ➞ 10/21301917
J6 CBC 1000 5P 205 B 54 x 11,11 (1)(3) ➞ 10/21301022
J6 CCC 1000 5P 205 B 54 x 11,11 (1)(3) 10/21301023
J6 CCC 1002 5P 205 B 54 x 11,11 (1)(3)(4) 10/21301918
J6 CDC 1000 5P 205 B 54 x 11,11 (1)(3) ➞ 10/21301024
J6 CAC 1001 5P 205 B 54 x 11,11 (1)(3) ➞ ➞ 10/21301025
J6 CCC 1001 5P 205 B 54 x 11,11 (1)(3) 10/21301026
J7 CAC 1001 4P 300 B 54 x 11,11 (2)(3) ➞ ➞ 10/21301181
J7 CCC 1001 4P 300 B 54 x 11,11 (2)(3) 10/21301183
J7 CCC 1002 4P 300 B 54 x 11,11 (2)(3)(4) 10/21301919
(1) J6 pump replaces H6 pump - (2) J7 replaces H7 pump - (3) Type with flange - (4) Without in-line cut-of function
Note :
Range 1000 = Inlet and return 1/4" - Outlet nozzle 1/8" Range 1001 = Inlet and return 1/2G - Outlet nozzle 1/4" gas.
AJ Range without SOLENOID VALVE CAN REPLACE J PUMPS
The SUNTEC AJ oil pump is the basic model incorporating a pressure regulating valve with cut-off. This range has the same shaft and hub sizes as J and H pumps and can replace these types.
The AJ oil pump type 1000 and 1003 incorporates an in-line off function. The AJ oil pump type 1002 is built without in-line cut-off function.
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation nozzle side PressureOutlet Ref
AJ4 AC 1000 2P 110 B 54 x 11,11 (1) ➞ ➞ 10/20
301601
AJ4 CC 1000 2P 110 B 54 x 11,11 (1) 10/20301611
AJ4 DC 1000 3P 110 B 54 x 11,11 (1) ➞ 10/20301613
AJ4 CE 1002 2P 110 B 54 x 11,11 (1)(3) 10/30301612
AJ6 AC 1000 2P 200 B 54 x 11,11 (1) ➞ ➞ 10/20301651
AJ6 CC 1000 3P 200 B 54 x 11,11 (1) 10/20301661
AJ6 CC 1003 2P 200 B 54 x 8 (1)(2) 10/20301663
AJ6 CE 1002 3P 200 B 54 x 11,11 (1)(3) 10/30301664
AJ6 DC 1000 2P 200 B 54 x 11,11 (1) ➞ 10/20301671
(1) Type with flange - (2) Special type with shaft Ø 8 - (3) Without in-line cut-off function
E Range without SOLENOID VALVE FOR MEDIUM FUEL OIL
The SUNTEC E oil pump incorporates a pressure regulating valve with cut-off function. This range can be used with medium and light oil. The SUNTEC E oil pump type 1069 is built with a drilling to accept a heating preheater (temp. max. 120°C). With pressure regulator 14 to 30 bars.
The SUNTEC E type 1001 incorporates an in-line cut-off function. The SUNTEC E type 1069 are built without in-line cut-off function.
Type Flow l/h to 2800 tr/ mn and 10 bars M=Hub B=Flange
Ø=Shaft Features Rotation nozzle side PressureOutlet Ref
E4 NA 1001 6P 130 B 54 x 11,11 (3)(4) ➞ ➞ 14/30
301151
E4 NA 1069 6P 130 B 54 x 11,11 (3)(4)(5)(6) ➞ ➞ 14/30
301152
E4 NC 1001 6P 130 B 54 x 11,11 (3)(4) 14/30
301153
E4 NC 1069 6P 130 B 54 x 11,11 (3)(4)(5)(6) 14/30
301155
(1) Used for OERTLI E6CC and E7CC - (2) Strainer 170µm - (3) Strainer 550µm - (4) Type with flange - (5) Without in-line cut-off function - (6) Cover with hole for heating element
NOTE : All these pumps incorporate a flange.
Oil pump
Oi
l p
um
p
PO
E Range without SOLENOID VALVE FOR MEDIUM FUEL OIL
(continuation)The SUNTEC E oil pump incorporates a pressure regulating valve with cut-off function. This range can be used with medium and light oil. The SUNTEC E oil pump type 1069 is built with a drilling to accept a heating preheater (temp. max. 120°C). With pressure regulator 14 to 30 bars.
The SUNTEC E type 1001 incorporates an in-line cut-off function. The SUNTEC E type 1069 are built without in-line cut-off function.
Type 2800 tr/mn Flow l/h to and 10 bars
M=Hub B=Flange
Ø=Shaft Features Rotation nozzle side PressureOutlet Ref
E6 NA 1001 6P 228 B 54 x 11,11 (3)(4) ➞ ➞ 14/30
301161
E6 NA 1069 6P 228 B 54 x 11,11 (3)(4)(5)(6) ➞ ➞ 14/30301145
E6 NA 1070 6P 228 B 54 x 11,11 (3)(4)(6) ➞ ➞ 16/28301922
E6 NB 1001 5P 228 B 54 x 11,11 (3)(4) ➞ 14/30301162
E6 CC 1001 6P 228 B 54 x 11,11 (1)(2)(4) 14/30301166
E6 NC 1001 6P 228 B 54 x 11,11 (1)(3)(4) 14/30301163
E6 NC 1069 6P 228 B 54 x 11,11 (3)(4)(5)(6) 14/30301165
E6 ND 1001 6P 228 B 54 x 11,11 (3)(4) ➞ 14/30301164
E7 NA 1001 5P 340 B 54 x 11,11 (3)(4) ➞ ➞ 14/30301171
E7 NA 1069 5P 340 B 54 x 11,11 (3)(4)(5)(6) ➞ ➞ 14/30301170
E7 CC 1001 5P 340 B 54 x 11,11 (2)(4) 14/30301174
E7 NC 1001 5P 340 B 54 x 11,11 (1)(3)(4) 14/30301173
E7 NC 1069 5P 340 B 54 x 11,11 (3)(4)(5)(6) 14/30301175
(1) Used for OERTLI E6CC and E7CC - (2) Strainer 170µm - (3) Strainer 550µm - (4) Type with flange - (5) Without in-line cut-off function - (6) Cover with hole for heating element
NOTE : All these pumps incorporate a flange.
TA Range with PRESSURE REGULATOR for LIGHT and HEAVY FUEL OIL
For light and heavy fuel oil, viscosity mini 4 cSt, maxi 800 cST, temperature 140°C at 40 bars except T5 and TA5 : 30 bars.
New : Carbon oxyde deposit on the gear surface, autolubricant carbon bearing. Sintered iron crescent replaces bronze crescent for better resistance to heavy fuel oil. With pressure regulator.
Type 2800 tr/mn and Flow l/h to 10 bars
M=Hub B=Flange
Ø=Shaft Rotation Pressure Ref
TA2 A 4010 5 500 B 54 x 12* ➞ 7/40
301270
TA2 C 4010 5 500 B 54 x 12* 7/40301271
TA3 A 4010 5 750 B 54 x 12* ➞ 7/40301272
TA3 C 4010 5 750 B 54 x 12* 7/40301273
TA4 A 4010 5 1000 B 54 x 12* ➞ 7/40301274
TA4 C 4010 5 1000 B 54 x 12* 7/40301275
TA5 C 3010 5 1350 B 54 x 12* 7/30301277
Hub Ø 54, entraxe flange : 125mm - Shaft Ø 12mm - *With flange
NOTE : This range of pump may be fitted with a preheater.
T Range without REGULATOR for LIGHT and HEAVY FUEL OIL
Type 2800 tr/mn and Flow l/h to 10 bars
M=Hub B=Flange
Ø=Shaft Rotation Pressure Ref
T2 C 105 1400 B 70 x 20 (1) Maxi 40
301251
T3 A 105 2000 B 70 x 20 (1) ➞ Maxi 40
301252
T3 C 105 2000 B 70 x 20 (1) Maxi 40
301253
T4 A 105 2780 B 70 x 20 (1) ➞ Maxi 40
301254
T4 C 105 2780 B 70 x 20 (1) Maxi 40
301255
(1) With flange - Without pressure regulator. Hub Ø 70, entraxe flange : 150mm - Shaft Ø 20mm - Range 104 replaced by 105
NOTE : This range of pump may be fitted with a preheater. No adjusting screw. Maxi pressure 30 bars.
Oil pump
CSB.168
Oi
l p
um
p
PO
SUNTEC
PUMP
- SUNDSTRAND
FUEL
SUNDSTRAND
PUMP IDENTIFICATION TABLE
A
AM
SUNDSTRAND
A60 Type capacity l/hnozzle Strainer Rotation Pressure range bar Fixing without nozzle Hub meaningwithout
A : Normal 1 = 18 A = without A = Right L = 5 - 10 1 = Flange 0 or 1 1 = Ø 32 0 to 9
AM : with EV 2 = 25 Z = without C =Left M = 7 - 14 2 = Hub 2 = Ø 54
3 = 15 P = 10 - 18 4 = Ø 54
Example ➩ A 2 Z C M 2 0 1 4
Example for replacement : A2ZCM2014 is replaced by AN 47C 7328 ref 301750
SUNTEC
PUMP IDENTIFICATION TABLE
AN
AS
AP - AL
AT
SUNTEC Type Flow 2800 tr/mn 10 bars Rotation
Outlet nozzle
side Hub
Ø
Inlet/return Range Voltage Cable
A = FOD cut-off solenoid L = with in line valve 35 = 40l/h A = right right 2-7-8 = 1/4" Revision N° P = Screw by pass plugged 01 = 110V 00 = without25 = 25 cm 65 = 82l/h B = right left 95 = Ø32 4 = 1/8" 02 = 24V 35 = 35 cm 45 = 45 cm
C = left left Bleed pipe 05 = 220V 60 = 60 cm
D = left right 10 = 1m
Example AL 35 A 95 2 8 1 P 05 35
SUNTEC Type Flow 2800 tr/mn
10 bars Rotation
Outlet
nozzle side Range Hub meaningwithout
A = FOD AN = without solenoid valve 47 = 40l/h A = right right 7 = 1970 2 = Ø54
2 digits Revision N°
P = Screw bypass plugged D = without solenoid valve 57 = 58l/h B = right left 1 = 1992 3 = Ø32
AE = Pressure regulator
without in line cut-off 67 = 80l/h C = left left 1 = For same models 7 = with
4 = Ø54 AS = with solenoid valve 77 = 110l/h D = left right 5 = Ø32 AP = with solenoid valve
2 stages 97 = 130l/h lateral pressureport
AT2 2 stages with in line cut-off 45 = 45l/h A = right right 1 = withoout 95 = Ø32 AT3 same as AT2 + pressure
plug on cover B = right left C = left left D = left right Example AS 57 C 7 4 41 3 P
AJ
J and E
T
TA
SUNTEC Type Flow 2800 tr/mn
10 bars Rotation
Outlet nozzle
side Pressurein bar Flange Features
AJ = FOD 4 = 110l/h A = right right C - 10 to 20 1 = with 000 = standard
Revision N°
P = Screw bypass plugged 6 = 200l/h C = left left E - 10 to 30 + Hub 002 = Pierced nozzle, outlet no cut-off
D = left right Ø54 003 = shaft Ø8 without off
Example AJ 6 D C 1 003 2 P
SUNTEC Type Flow 2800 tr/mn
10 bars Filter Rotation Outlet no-zzle side
Pressure
in bar Flange Features
J = FOD 3 = 90l/h C A = right right B - 7 to 14 1 = with 000 = 1/2 conic
Revision
N° P = Screw bypass plugged 4 = 110l/h B = right left C - 10 to 21
6 = 205l/h C = left left K - 14 to 30 001 = 1/2 cylindric
7 = 300l/h D = left right Example J 3 C B B 1 000 4 P
Oil pump
Oi
l p
um
p
PO
SUNTEC
PUMP IDENTIFICATION TABLE
(continuation)AJ
J and E
T
TA
SUNTEC Type Flow 2800 tr/mn15 bars to 20cst Filter Rotation Outlet nozzle side Flange Features
E = FL 4 = 130l/h C = 170mM A = right right 10 = with 01 = standard
Revision
N° P = Screw bypass plugged
6 = 228l/h B = right left 69 = Cover with hole for
heating element
7 = 340l/h C = left left
N = 550mM D = left right
Example E 4 N C 10 69 5 P
SUNTEC Type Flow 2800 tr/mn10 bars Rotation Pressure Features
TA = FL or FOD 2 = 500l/h A = right 30 = 7 to 30 bar
10 = Cover with hole for heating element Revision N° 3 = 760l/h C = left 40 = 7 to 40 bar
4 = 1000l/h 5 = 1360l/h
Example TA 2 C 40 10 5
T = FL or FOD 2 = 1400l/h A = right
10 = Cover with hole for heating element Revision N° 3 = 2000l/h C = left
4 = 2900l/h 5 = 3950l/h
Example T 4 C 10 5
SUNTEC
PUMP ACCESSORIES
SHAFT SEAL REPAIR KIT
Description Mark Ref
AN - AS - AE - AL - AT - D - AP - A2L type (SUNTEC ref. 991515/991511)
1
301391
AJ type (SUNTEC ref. 270202)
1
301342
J - H - E 1000/1001 type (SUNTEC ref. 993473)
2
301340
E 1063/1069 type (SUNTEC ref. 132632)
2
301362
T type Revision 3 Shaft seal kit (SUNTEC ref. 991911)
3
301383
T type Revision 4/5 Shaft seal kit (SUNTEC ref. 1914462)
3
301380
TA type Revision 2/4/5 Shaft seal kit(SUNTEC ref. 2014462)
3
301381
Shaft E4 type 1063/1069(SUNTEC ref. 993009)
4
301363
Shaft E6 - E7 type 1063/1069 (SUNTEC ref. 993010)
4
301364
Shaft seal wrench Ø 4mm entraxe 25mm J - H - E (SUNTEC ref. 27005)
5
301370
COVER GASKET
Description Mark Ref
AJ gasket (original piece) (SUNTEC ref. 270112)
1
301436
AJ gasket (adaptable piece)
1
301435
AJ gasket (original piece)
1
301437
J - H - E gasket (original piece) (SUNTEC ref. 110441/135803)
2
301411
J - H - E gasket (adaptable piece)
2
301410
J - H - E gasket (original piece)
2
301412
A1 - A2 gasket
3
301420
AN - AS - AE - AL - AP - AT gasket (SUNTEC ref. 3759811/991523)
AN/AE/AS/AP 47-57-67 range 7000 rev.2 cast cover - AN/AE 77-97 range 7000 rev.2 cast cover AN/AE/AS/AP 47-57-67 range 7000 rev.3 and 5 - AN/AE/AS/AP 47-57-67 range 1000 rev.1 and 5 - AL/ALE/A2L/AR 35-55-65 range 9000 revision 1-2-5 - AT2/AT3 45-55-65 range 9000 revision 1-2-5 - AP2/AP3 45-55-65 range 9000 revision 1 - AN/AE 77-97 range 7000 revision 3 -
AL/A2L/AR/AT2 75-95 range 9000 revision 2 and 5 - AP2 75-95 range 9000 revision 1 -
new aluminium cover 82 (width 0,65mm)(original piece)
4
301433
AN - AS - AE - AL - AP - AT gasket (SUNTEC ref. 3759811/991523)
AN/AE/AS/AP 47-57-67 range 7000 rev.2 cast cover - AN/AE 77-97 range 7000 rev.2 cast cover AN/AE/AS/AP 47-57-67 range 7000 rev.3 and 5 - AN/AE/AS/AP 47-57-67 range 1000 rev.1 and 5 - AL/ALE/A2L/AR 35-55-65 range 9000 rev.1-2-5 - AT2/AT3 45-55-65 range 9000 rev.1-2-5 - AP2/AP3 45-55-65 serie 9000 rev.1 - AN/AE 77-97 range 7000 rev.3 -
AL/A2L/AR/AT2 75-95 serie 9000 rev.2 and 5 - AP2 75-95 range 9000 rev.1
new aluminium cover 82 (width 0,65mm) (adaptable piece)
4
301432
1
2
3
4
x 12 x 10 x 12 x 10 x 12 x 10 x 121
2
3
4
5
Oil pump
CSB.170
Oi
l p
um
p
PO
COVER GASKET
(continuation)Description Mark Ref
AN - AS - AE - AP gasket (SUNTEC ref. 991524)
AN/AE/AS/AP 47-57-67 range 7000 rev.4 and 6 fl ate cover - AN/AE/AS/AP 47-57-67 range 1000 rev.4 and 6
fl ate cover - AL/ALE 35-55-65 range 9000 rev.4 and 6 - AT2/AT3 45-55-65 range 9000 rev.4 and 6 -
AP2/AP3 45-55-65 range 9000 rev.4 et 6 - new fl ate cover (original piece) x 10
-
301434
cover Kit AN - AS - AE - AL - AP - AT rotation A-D
(range 35-45-55-65-47-57-67 Rev 2-3) (SUNTEC ref. 991475)
5
301580
cover Kit AN - AS - AE - AL - AP - AT rotation B-C
(range 35-45-55-65-47-57-67 Rev 2-3) (SUNTEC ref. 991476)
5
301581
cover Kit AN-AE-AP2-AT2-AL-ALE-A2L-AR rotation B-C
(range 75-95-77-97 Rev 3) (SUNTEC ref. 991509)
5
301582
STRAINER PUMP
Description Mark Ref
AN/AS/AE/AP range 47-57-67 range 7000 rev.3-4-5-6 aluminium cover (SUNTEC ref. 3715741)
2
301561
AN/AS/AE/AP 47-57-67 range 1000 rev.1-4-5-6 without bosses - AL/ALE/A2L/AR/AT2/AT3/AP2/AP3
range 9000 rev.1-2-4-5-6 (SUNTEC ref. 3715741)
2
301561
AN/AE 77-97 range 7000 revision 2 (SUNTEC ref. 3715732)
3
301563
A1/A2/AN/AS/AE/AP range 47-57-67 rev. 2 (SUNTEC ref. 3715735/3715732)
3
301563
AJ 39 mm (SUNTEC ref. 270087)
4
301565
J - H - E Filter "C" - 170µ 55mm (SUNTEC ref. 134423)
4
301540
E Filter "N"-550µ SUNTEC (ref. 134433)
4
301550
AP2 - AT2 75 and 95 (SUNTEC ref 3715750)
-
301566
D revision 3 (SUNTEC ref. 3715747)
-
301567
SOLENOID KIT
Description Mark Ref
Solenoid kit All AS types 220 volts (SUNTEC ref. 991435)
1
301470
Solenoid kit All AS types 110 volts (SUNTEC ref. 991431)
1
301473
Solenoid kit All AP types 220 volts for 47/57/67 (SUNTEC ref. 991455)
1
301472
Solenoid kit All AL types 220 volts revision 2 - 4 - 5 - 6 (SUNTEC ref. 3713798/991502)
1
301468
Solenoid kit All AT types rot.A/D revision 2 (SUNTEC ref. 3713798/991503)
2
301466
Solenoid kit AP 2/3 rot.B/C (SUNTEC ref. 991489)
2
301474
SOLENOID VALVE COIL
Description Ref
Solenoid valve coil 220 volts (SUNTEC ref. 3713798)
301478
Solenoid valve coil 110 volts (SUNTEC ref. 3713797)
301479
Solenoid valve coil 24 volts (SUNTEC ref. 3713796)
301477
Solenoid valve coil 24 volts continuous (SUNTEC ref. 3713818)
301481
SOLENOID VALVE CONNECTOR
Description Ref
AMP moulded connector with 3 leads 0.40m, for Rapa valve and SUNTEC solenoid valves
803030
AMP moulded connector with 3 leads 0,80m, for Rapa valve and SUNTEC solenoid valves
803029
AMP moulded connector for Rapa valve and SUNTEC solenoid valves
803034
CHANGING KIT PUMP - BY PASS PLUG
Description Ref
Changing AU pump kit to AE pump (SUNTEC ref.991401)
301589
Changing AS pump kit to AN pump (SUNTEC ref.991400)
301590
By-pass plug for AN-AS-AL-AP-AT-D pump (SUNTEC ref.3779858)
301469
5
1
2
4 x 6 x 6 x 1 x 6Oil pump
Oi
l p
um
p
PO
FLANGE AND ADAPTER HUB
Description Mark Ref
Flange with 2 holes entraxe 92 mm (SUNTEC ref.132752)
1
301300
Flange for changing hub 32mm without fl ange to hub 54mm with fl ange
(SUNTEC ref.3719003)
2
301301
Adapter Hub to obtain hub
ø
54 mm with hubø
32 mm(SUNTEC ref.3759833)
3
301310
Shaft Extension to obtain
ø
11,11 with shaftø
8 mm(SUNTEC ref.3754737)
4
601130
ELECTRIC PREHEATER AND REGULATOR
Description Mark Ref
Electric preheater for heavy fuel oil cover pump type E 1069 T/TA
1
404956
Regulator kit for pump J 1069 T/TA (SUNTEC ref.991410)
2
301450
Low pressure regulator replaces only on AJ pump, Revision 2 only, the original regulator to get an adjusting
range 0,7 to 3 bars (SUNTEC ref.270716)
3
301452
Low pressure regulator replaces on AN-AS-AE-AL-AT-AP pump, revision 2 only, the original regulator to get an
adjusting range for 0,7 to 3 bars (SUNTEC ref.991500)
3
301453
ATCO - FRANCIA - SICMA
PUMP
RANGE of PUMP REPLACED by
SUNTEC
Range P4 - M7 - M9 - M11 - M13 - M15. This pump is not yet manufactured. Replaced by SUNTEC pump with same technical features...
Type Flow l/h to 2800 tr/mn & 10 bar Ø Hub and shaft in mm Characte-ristic RotationNozzle outlet Ref
P4 - LL 28 M 32x8
301750
P4- RL 28 M 32x8 ➞
301044
P4 - LL Sib or PV4 with solenoid valve 28 M 32x8
301088
P4 - RL Sib or PV4 with solenoid valve 28 M 32x8 ➞
301084
M15 - R15 170 B 54x11.11 (1)(2) ➞ ➞
301604
M15 - L15 (2)
301605
(1) With fl ange - (2) Delivered with adapter kit
Nota : These pumps replace ATCO pumps, not fi tted with ring for air fl ap
DANFOSS
PUMP
DANFOSS
PUMPS IDENTIFICATION TABLE
RS
MS
MS21
BFP
DANFOSS Type Rotation Flow to 2800 tr/mnAdjustment 10 bars Size shaft By-pass screw
RS without EV 43 = 12l/h 2-3 = Ø8
RSA without EV right left 31 = 32l/h 0 = no plugged
RSH without EV 53 = 45l/h 0-3-5-7 = Ø10
RSL without EV 070 070L 32 = 75l/h 2 = plugged
RSLB without EV 33 = 100l/h 1-4-6-8 = Ø11,11
Example ➩ RS 60 070L 33 6 2
MSLA with EV right left
MSLB without EV 071B0 071B1 032 = 24l/h 10 or 20 = Ø8 2-4-6-8 = plugged
MSLC without EV 071B2 071B3 050 = 52l/h hub Ø32 1-3-5-7 = no plugged
071B4 071B5 Example ➩ MSLB 071B3 032 10 2 MS10 without EV R L 3 = 45l/h no meaning071G0... MS11 with EV MS12 with EV 5 = 70l/h MS21 with EV Example ➩ MS11 R 3 071G0126 1 2
3
4
1
2
3
Oil pump
CSB.172
Oi
l p
um
p
PO
DANFOSS
PUMP
DANFOSS
OLD PUMP REPLACEMENT TABLE
Component Description Manufact. ref
DANF 70-3130 Danfoss pump 70-3130 70-3130 = 303432
DANF 70-3132 70-3132 70-3132 = 303432 DANF 70-3140 70-3140 303432 + 301310 DANF 70-3142 70-3142 303432 + 301310 DANF 70-3200 70-3200 70-3200 = 303031 DANF 70-3202 70-3202 70-3202 = 303031 DANF 70-3210 70-3210 70-3210 = 303033 DANF 70-3212 70-3212 70-3212 = 303033 DANF 70-3230 70-3230 70-3230 = 303031 DANF 70-3232 70-3232 70-3232 = 303031 DANF 70-3240 70-3240 70-3240 = 303033 DANF 70-3242 70-3242 70-3242 = 303033 DANF 70-3300 70-3300 -DANF 70-3302 70-3302 -DANF 70-3310 70-3310 70-3310 = 303043 DANF 70-3312 70-3312 70-3312 = 303043 DANF 70-3350 70-3350 -DANF 70-3352 70-3352 -DANF 70-3360 70-3360 70-3360 = 303043 DANF 70-3362 70-3362 70-3362 = 303043 DANF 70-3410 70-3410 70-3410 = 303093 DANF 70-3412 70-3412 70-3412 = 303093 DANF 70-4030 70-4030 70-4030 = 303430 DANF 70-4032 70-4032 70-4032 = 303430 DANF 70-4040 70-4040 303430 + 301310 DANF 70-4042 70-4042 303430 + 301310 DANF 70-4120 70-4120 70-4120 = 303430 DANF 70-4121 70-4121 70-4121 = 303430 DANF 70-4130 70-4130 70-4130 = 303432 DANF 70-4132 70-4132 70-4132 = 303432 DANF 70-4140 70-4140 303432 + 301310 DANF 70-4142 70-4142 303432 + 301310 DANF 70-4330 70-4330 70-4330 = 303430 DANF 70-4332 70-4332 70-4332 = 303430 DANF 70-4340 70-4340 303430 + 301310 DANF 70-4342 70-4342 303430 + 301310 DANF 70-4492 70-4492 70-4492 = 303432 DANF 70-5300 70-5300 70-5300 = 303021 DANF 70-5302 70-5302 70-5302 = 303021 DANF 70-5322 70-5322 70-5322 = 303025 DANF 70-5330 70-5330 70-5330 = 303025 DANF 70-5332 70-5332 70-5332 = 303025 DANF 70-5370 70-5370 70-5370 = 303021 DANF 70-5372 70-5372 70-5372 = 303021 DANF 70-6400 70-6400 70-6400 = 301171 DANF 70-6410 70-6410 70-6410 = 301171 DANF 70-6480 70-6480 70-6480 = 301161 DANF 70-7300 70-7300 70-7300 = 301151 DANF 70-7310 70-7310 70-7310 = 301151 DANF 70L 3002 70L 3002 - DANF 70L 3130 70L 3130 70L 3130 = 303433 DANF 70L 3132 70L 3132 70L 3132 = 303433 DANF 70L 3140 70L 3140 303433 + 301310 DANF 70L 3142 70L 3142 303433 + 301310 DANF 70L 3200 70L 3200 -DANF 70L 3202 70L 3202 -DANF 70L 3210 70L 3210 70L 3210 = 303034 DANF 70L 3212 70L 3212 70L 3212 = 303034 DANF 70L 3230 70L 3230 -DANF 70L 3232 70L 3232 -DANF 70L 3240 70L 3240 70L 3240 = 303034 DANF 70L 3242 70L 3242 70L 3242 = 303034 DANF 70L 3300 70L 3300 70L 3300 = 303042 DANF 70L 3302 70L 3302 70L 3302 = 303042 DANF 70L 3310 70L 3310 70L 3310 = 303044 DANF 70L 3312 70L 3312 70L 3312 = 303044 DANF 70L 3350 70L 3350 70L 3350 = 303042 DANF 70L 3352 70L 3352 70L 3352 = 303042 DANF 70L 3360 70L 3360 70L 3360 = 303044 DANF 70L 3362 70L 3362 70L 3362 = 303044 DANF 70L 3400 70L 3400 70L 3400 = 303092 DANF 70L 3402 70L 3402 70L 3402 = 303092 DANF 70L 3410 70L 3410 70L 3410 = 303094 DANF 70L 3412 70L 3412 70L 3412 = 303094 DANF 70L 3480 70L 3480 70L 3480 = 303054 DANF 70L 3482 70L 3482 70L 3482 = 303054 DANF 70L 4030 70L 4030 70L 4030 = 303431 DANF 70L 4032 70L 4032 70L 4032 = 303431 DANF 70L 4040 70L 4040 303431 + 301310 DANF 70L 4042 70L 4042 303431 + 301310 DANF 70L 4130 70L 4130 70L 4130 = 303433 DANF 70L 4132 70L 4132 70L 4132 = 303433
Component Description Manufact. ref
DANF 70L 4140 Danfoss pump 70L 4140 303433 + 301310
DANF 70L 4142 70L 4142 303433 + 301310 DANF 70L 4330 70L 4330 70L 4330 = 303431 DANF 70L 4332 70L 4332 70L 4332 = 303431 DANF 70L 4340 70L 4340 303433 + 301310 DANF 70L 4342 70L 4342 303431 + 301310 DANF 70L 5300 70L 5300 70L 5300 = 303022 DANF 70L 5302 70L 5302 70L 5302 = 303022 DANF 70L 5310 70L 5310 70L 5310 = 303024 DANF 70L 5312 70L 5312 70L 5312 = 303024 DANF 70L 5322 70L 5322 70L 5322 = 303026 DANF 70L 5330 70L 5330 70L 5330 = 303026 DANF 70L 5332 70L 5332 70L 5332 = 303026 DANF 70L 5370 70L 5370 70L 5370 = 303022 DANF 70L 5372 70L 5372 70L 5372 = 303022 DANF 70L 5380 70L 5380 70L 5380 = 303024 DANF 70L 5382 70L 5382 70L 5382 = 303024 DANF 70L 5392 70L 5392 70L 5392 = 303026 DANF 70L 6400 70L 6400 70L 6400 = 301173 DANF 70L 6410 70L 6410 70L 6410 = 301173 DANF 70L 6480 70L 6480 70L 6480 = 301163 DANF 70L 7300 70L 7300 70L 7300 = 301153 DANF 70L 7310 70L 7310 70L 7310 = 301153 DANF 71B 0030 71B 0030 -DANF 71B 0101 71B 0101 71B 0101 = 303400 DANF 71B 0102 71B 0102 71B 0102 = 303400 DANF 71B 0103 71B 0103 303400 + 303357 DANF 71B 0104 71B 0104 303400 + 303357 DANF 71B 0105 71B 0105 303400 + 303357 DANF 71B 0106 71B 0106 303400 + 303357 DANF 71B 0107 71B 0107 71B 0107 = 303400 DANF 71B 0108 71B 0108 71B 0108 = 303400 DANF 71B 0112 71B 0112 71B 0112 = 303400 DANF 71B 0113 71B 0113 71B 0113 = 303400 DANF 71B 0132 71B 0132 303400 + 303359 DANF 71B 0201 71B 0201 71B 0201 = 303402 DANF 71B 0202 71B 0202 71B 0202 = 303402 DANF 71B 0203 71B 0203 303402 + 303357 DANF 71B 0204 71B 0204 303402 + 303357 DANF 71B 0205 71B 0205 303402 + 303357 DANF 71B 0206 71B 0206 303402 + 303357 DANF 71B 0207 71B 0207 71B 0207 = 303402 DANF 71B 0208 71B 0208 71B 0208 = 303402 DANF 71B 1101 71B 1101 71B 1101 = 303401 DANF 71B 1102 71B 1102 71B 1102 = 303401 DANF 71B 1103 71B 1103 303401 + 303357 DANF 71B 1104 71B 1104 303401 + 303357 DANF 71B 1105 71B 1105 303401 + 303357 DANF 71B 1106 71B 1106 303401 + 303357 DANF 71B 1107 71B 1107 303401 + 303357 DANF 71B 1108 71B 1108 71B 1108 = 303401 DANF 71B 1111 71B 1111 71B 1111 = 303401 DANF 71B 1112 71B 1112 71B 1112 = 303401 DANF 71B 1114 71B 1114 303401 + 303357 DANF 71B 1116 71B 1116 303401 + 303357 DANF 71B 1120 71B 1120 71B 1120 = 303401 DANF 71B 1122 71B 1122 71B 1122 = 303401 DANF 71B 1126 71B 1126 303401 + 303357 DANF 71B 1128 71B 1128 71B 1128 = 303401 DANF 71B 1132 71B 1132 303401 + 303359 DANF 71B 1134 71B 1134 71B 1134 = 303401 DANF 71B 1136 71B 1136 71B 1136 = 303401 DANF 71B 1138 71B 1138 71B 1138 = 303401 DANF 71B 1201 71B 1201 71B 1201 = 303403 DANF 71B 1202 71B 1202 71B 1202 = 303403 DANF 71B 1203 71B 1203 303403 + 303357 DANF 71B 1204 71B 1204 303403 + 303357 DANF 71B 1206 71B 1206 303403 + 303357 DANF 71B 1207 71B 1207 71B 1207 = 303403 DANF 71B 1208 71B 1208 71B 1208 = 303403 DANF 71B 2101 71B 2101 71B 2101 = 303430 DANF 71B 2102 71B 2102 71B 2102 = 303430 DANF 71B 2104 71B 2104 71B 2104 = 303430 DANF 71B 2201 71B 2201 71B 2201 = 303432 DANF 71B 2202 71B 2202 71B 2202 = 303432 DANF 71B 2203 71B 2203 71B 2203 = 303432 DANF 71B 3101 71B 3101 71B 3101 = 303431 DANF 71B 3102 71B 3102 71B 3102 = 303431 DANF 71B 3103 71B 3103 71B 3103 = 303431 DANF 71B 3201 71B 3201 71B 3201 = 303433 DANF 71B 3202 71B 3202 71B 3202 = 303433 DANF 71B 4101 71B 4101 71B 4101 = 303430