(1)

Oil pump

PO

Oi

l p

um

p

PO

Oil pump and accessories

SUNTEC ... CSB.160

DANFOSS ... CSB.172

DELTA ... CSB.178

ECKERLE ... CSB.179

RIELLO ... CSB.181

SAFAG ... CSB.182

SP ... CSB.183

Solenoid valve ... CSB.183

Transfer pump ... CSB.185

Suctionpump ... CSB.190

Carburettor ... CSB.194

CSB

SUNTEC pump

Solenoid valve

Transfer pump

GPS-10

oil suction

transfer unit

Carburettor

(2)

YOU SEARCH A PUMP

You must know :

•Burner mark •Burner type

•Burner number •Burner manufacturing year But many burner manufacturers use different pumps on the same burner. So you can note :

The engraved pump reference

But if it is not possible to read this information you must note : •Ø of shaft •shaft rotation (with shaft in front of you) •Ø of hub •outlet nozzle side (with shaft in front of you) •with fl ange •with solenoid valve

•or without fl ange •or without solenoid valve •nozzle capacity

DISTRIBUTED BY DIFF

SUNTEC

AU 47 revision 6

P

Description Ref

SUNTEC Suitcase with 2 AU 47 pumps

301992

Contains 2 AU pumps and accessories, allows to repair the majority of burner oil pump or kerosene pump

with or without solenoid valve, with right or left rotation, with right or left outlet nozzle position, with or without flange can be repaired.

Type tr/mn and 10 barsFlow l/h to 2800 Ø=ShaftM=Hub Rotation nozzle sideOutlet Pressurebar Ref

AU 47 L 9853 6P0500 40 M 32 x Ø8  ➞ 4/25

301870

AU 47 R 9852 6P0500 40 M 32 x Ø8 ➞ ➞ 4/25

301871

In this suitcase you have also spare parts and accessories for maintenance.

Suitcase components :

1 AU 47 L pump (left rotation, left or right outlet nozzle position). Diff ref 301870

1 AU 47 R pump (right rotation, left or right outlet nozzle position). Diff ref 301871

2 connectorsDiff ref 803030

2 strainers Diff ref 301561

1 coil 220-240V, 50/60 Hz Diff ref 301478

2 cover gaskets Diff ref 301434

1 changing kit AU pump to AE pump Diff ref 301589

1 adapter hub Ø32 / 54 Diff ref 301310

1 flange allows to obtain a pump with fixing flange and hub Ø54 Diff ref 301301

1 TEFEM 1/8-1/8 Diff (from connection) ref 602510

1 Extension shaft pupm DN8/11,1 Diff ref 601130

Universal replacement pump

2 pumps replace

51 Suntec models

24 Delta Fuel Master models

and 105 Danfoss models

Suntec proposes a new pump specially designed for maintenance market : The AU 47 revision 6 pump

Technical features :

Better stock control

Quick and easy installation

✓Outlet nozzle on the right or on the left

✓Normally closed solenoid valve

✓Same performance and quality as SUNTEC type “A“

AU revision 6 pumps replace more pumps than AU revision 2.

The photographic model is an «AU 47L» (left rotation - Outlet nozzle on the right or on the left, in front of the shaft)

So, the suitcase with 2 AU47 pumps (left and right rotation), 1 adaptor hub, 1 flange and 1 changing AU to AE pump kit can replace 95% of low flow pumps.

AU 47 R 9852 6P 0500 Pump Diff ref 301871 AU 47 L 9851 6P 0500 Pump Diff ref 301870

IMPORTANT

Note : The new AU 47 revision 6 pump allows a direct sealing at the bottom of the inlet and return ports. It is not possible with AU 47 revision 2.

All these accessories are also separately sold for the suitcase restocking

Oil pump

CSB.160

Oi

l p

um

p

PO

(3)

A2L Range with 2 SOLENOID VALVES

The SUNTEC A2L oil pump has two nozzle outlets. It incorporates two blocking solenoid valves with in-line cut-off function, one for each nozzle outlet.

Application : ✓ Domestic Fuel oil ✓ 2 nozzle outlets ✓ 2 blocking solenoid valves with in-line cut-off function ✓ 1 regulator for both nozzle lines

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet nozzle

side Pressure Ref

A2L 65 A 9708 2P 0500 82* M32x8 - ➞ ➞ 8/15

301892

A2L 65 B 9707 2P 0500 82* M32x8 - ➞ ➞ 8/15

301893

A2L 65 C 9704 2P 0500 82* M32x8 (1)  ➞ 7/14

301894

A2L 65 D 9703 2P 0500 82* M32x8 (2)  ➞ 8/15

301930

A2L 75 C 9701 2P 0500 110* M32x8 (1)  ➞ 7/14

301895

A2L 95 B 9711 2P 0500 132* M32x8 - ➞ ➞ 9/25

301896

A2L 95 D 9702 2P 0500 132* M32x8 (2)  ➞ 8/15

301931

(1) Kerosene - (2) Inlet and Return M16 - * With air jack outlet

AL Range with SOLENOID VALVE

The SUNTEC AL oil pump incorporates a blocking solenoid valve with in-line cut-off function. Bleeding in two-pipe operation is auto-matic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system.. Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet nozzle

side Pressure Ref

AL 30 C 9537 4P 0500 40 M 32 x 8 -   8/15

301946

AL 35 A 9526 2P 0500 40 M 32 x 8 - ➞ ➞ 8/15

301949

AL 35 A 9570 2P 0500 40* M 32 x 8 - ➞ ➞ 8/15

301958

AL 35 A 9596 2P 0100 40* M 32 x 8 (5) ➞ ➞ 8/15

301936

AL 35 A 9596 2P 0500 40* M 32 x 8 - ➞ ➞ 8/15

301869

AL 35 B 9580 2P 0500 40* M 32 x 8 - ➞  8/15

301956

AL 35 C 9521 2P 0100 40 M 32 x 8 (5)   4/18

301938

AL 35 C 9521 2P 0500 or AL 35C 9519 6P 0500 40 M 32 x 8 -   4/18

301873

AL 35 C 9528 2P 0500 40 M 32 x 8 -   8/15

301957

AL 35 C 9540 2P 0500 40 M 32 x 8 (1)   8/15

301950

AL 35 C 9545 1P 0500R 40 M 32 x 8 (1)   8/15 see 301950 AL 35 C 9578 2P 0500R 40* M 32 x 8 -   8/15 see 301987 AL 35 D 9529 2P 0200 40 M 32 x 8 (2)  ➞ 8/15

301959

AL 35 D 9529 2P 0500 40 M 32 x 8 -  ➞ 8/15

301939

AL 35 D 9595 2P 0500 40 M 32 x 8 (6)  ➞ 8/15 see 301939 AL 55 C 9598 2P 0500 60 M 32 x 8 (4)(6)   10/25 see 301986 AL 65 B 9532 2P 0500 82 M 32 x 8 - ➞  4/18

301877

AL 65 C 9410 2P 0500 82* B 54 x 8 -   4/18

301879

AL 65 C 9525 2P 0500 82 M 32 x 8 (3)   8/15

301980

AL 65 C 9588 2P 0500 82* M 32 x 8 -   8/15

301981

AL 65 C 9589 2P 0500 82 M 32 x 8 -   8/15

301982

AL 75 B 9539 2P 0500 110 M 32 x 8 - ➞  8/15

301880

AL 75 C 9411 2P 0500 110* B 54 x 8 -   4/18

301881

AL 95 C 9412 2P 0500 132* B 54 x 8 -   10/20

301984

AL 95 C 9414 2P 0500 132* B 54 x 8 (7)   10/20

301882

AL 65 C 9525 2P 0500 82 M 32 x 8 (5)   8/15

301980

AL 65 C 9588 2P 0500 82* M 32 x 8 -   8/15

301981

AL 65 C 9589 2P 0500 82 M 32 x 8 -   8/15

301982

AL 75 B 9539 2P 0500 110 M 32 x 8 - ➞  8/15

301880

AL 75 C 9411 2P 0500 110* B 54 x 8 -   4/18

301881

AL 75 C 9534 2P 0500 110 M 32 x 8 (5)(6)   8/15

301983

AL 95 C 9412 2P 0500 132* B 54 x 8 -   10/20

301984

AL 95 C 9414 2P 0500 132* B 54 x 8 (10)   10/20

301882

(1) Inlet and Return.1/8" - (2) Coil 24 VAC - (3) Conical nipple Ø4 - (4) Kerosene - (5) Coil 110VAC - (6) Adjusting screw pressure on the nozzle side. (7) Shaft with 2 flat surfaces *With outlet air jack.

ALE Range with SOLENOID VALVE

The SUNTEC ALE oil pump incorporates a blocking solenoid valve fitted with a built-in return valve ensuring an in-line cut-off function and a nozzle line pressure relief. Bleeding in two pipe operation is automatic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system. Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet nozzle

side Pressure Ref

ALE 35 A 9325 2P 0500 40 M 32 x 8 - ➞ ➞ 8/15

301883

ALE 35 C 9322 2P 0500 40 M 32 x 8 -   10/25

301886

ALE 35 C 9324 2P 0500 40 M 32 x 8 -   4/18

301888

ALE 35 C 9327 2P 0500 40* M 32 x 8 -   8/15

301889

ALE 35 C 9328 2P 0500 40* M 32 x 8 (1)   8/15

301890

ALE 35 C 9329 6P 0500 40 M 32 x 8 (2)(3)   12/25

301985

ALE 35 C 9334 2P 0500* 40 M 32 x 8 (4)   8/15

301987

ALE 55 C 9330 2P 0500 58 M 32 x 8 (2)(3)   12/25

301986

(1) Kerosene - (2) Adjusting pressure screw on the nozzle side - (3) Shaft with 2 flat surfaces (4) Direct sealing Inlet and Return *With outlet air jack

Oil pump

Oi

l p

um

p

PO

(4)

AR Range with SOLENOID VALVE

The SUNTEC AR oil pump incorporates a blocking solenoid valve with in-line cut-off function and a second regulator for nozzle return pipe. Bleeding in two pipe operation is automatic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system

Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet nozzle

side Pressure Ref

AR 65 A9801 2P 0500 75 M 32 x 8 ➞ ➞ 12/25 5/15

301897

AN Range without SOLENOID VALVE

The SUNTEC AN oil pump is the basic model incoporating pressure regulation valve with cut-off.

Information AN

The pumps in grey line can be used for the other pump replacements with adding flange or adapter hub. In this way you can decrease your stock and increase your possibilities of repair and maintenance.

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

AN 47 A 7216 3P 40 B 54 x 8 (2)(4) ➞ ➞ 7/14

301041

AN 47 A 7283 2M 40 B 54 x 8 (1)(3)(4) ➞ ➞ 7/14 see 301041 AN 47 B 7217 3P 40* B 54 x 8 (2)(4) ➞  7/14

301732

AN 47 C 7218 3P 40 B 54 x 8 (2)(4)   7/14

301734

AN 47 D 7219 3P 40 B 54 x 8 (2)(4)  ➞ 7/14

301047

AN 47 A 1326 1P 40 M 32 x 8 - ➞ ➞ 7/14

301731

AN 47 A 7326 3P 40* M 32 x 8 - ➞ ➞ 7/14

301733

AN 47 A 7226 3P 40 M 54 x 8 (2) ➞ ➞ 7/14

301042

AN 47 B 1395 1P 40 M 32 x 8 - ➞  7/14

301049

AN 47 B 7227 3P 40* M 54 x 8 (2) ➞  7/14

301043

AN 47 B 7327 3P 40* M 32 x 8 - ➞  7/14

301044

AN 47 C 1342 1P 40 M 32 x 8 -   7/14

301750

AN 47 C 7228 3P 40 M 54 x 8 (2)   7/14

301045

AN 47 C 7247 3M 40* B 54 x 8 (1)(6)(4)   7/12

301737

AN 47 C 7328 3P 40* M 32 x 8 (4)   7/14

301738

AN 47 C 7342 3P 40* M 32 x 8 -   7/14

301739

AN 47 D 1339 1P 40 M 32 x 8 -  ➞ 7/14

301749

AN 47 D 7229 3P 40 M 54 x 8 (2)  ➞ 7/14

301048

AN 47 D 7329 3P 40 M 32 x 8 (2)  ➞ 7/14

301749

AN 57 A 7351 3P 58* M 32 x 8 - ➞ ➞ 7/14

301742

AN 57 B 1330 1P 58 M 32 x 8 - ➞  10/20

301054

AN 57 C 7282 3P 58* B 54 x 8 (4)   7/14

301743

AN 67 A 7238 3P 82* B 54 x 8 (4) ➞ ➞ 10/20

301071

AN 67 A 7345 3P 82* M 32 x 8 (4) ➞ ➞ 10/20

301076

AN 67 B 1335 1P 82 M 32 x 8 - ➞  10/20

301074

AN 67 B 7251 3P 82* B 54 x 8 (4) ➞  10/20

301073

AN 67 B 7287 3P 82* M 54 x 8 - ➞  10/20

301064

AN 67 C 1336 1P 82 M 32 x 8 (4)   7/14

301065

AN 67 C 1338 1P 82 M 32 x 8 (6)(7)   7/12

301746

AN 67 C 7233 3P 82* B 54 x 8 (4)   10/20

301075

AN 67 C 7242 3P 82* M 54 x 8 -   10/20

301066

AN 67 D 7252 3P 82* B 54 x 8 (4)   10/20

301077

AN 77 A 7255 2P 112* M 54 x 8 - ➞ ➞ 10/20

301904

AN 77 A 7256 2P 112* B 54 x 8 - ➞ ➞ 10/20

301752

AN 77 C 7235 2P 112* B 54 x 8 (4)   10/20

301905

AN 77 C 7275 2P 112* M 54 x 8 -   10/20

301756

AN 77 C 7341 2P 112* M 32 x 8 -   10/20

301906

AN 97 A 7391 2P 132* M 32 x 8 - ➞ ➞ 10/20

301758

AN 97 C 7257 2P 132* B 54 x 8 (4)   10/20

301920

AN 67 D 7252 3P 82* B 54 x 8 (4)   10/20

301077

AN 77 A 7255 2P 112* M 54 x 8 - ➞ ➞ 10/20

301904

AN 77 A 7256 2P 112* B 54 x 8 - ➞ ➞ 10/20

301752

AN 77 A 7266 2M 112* B 54 x 8 (1)(4) ➞ ➞ 10/15

301753

AN 77 A 7295 2P 112* M 54 x 8 (9) ➞ ➞ 10/20

301754

AN 77 A 7346 2P 112* M 54 x 8 - ➞ ➞ 10/20

301796

AN 77 C 7235 2P 112* B 54 x 8 (4)   10/20

301905

AN 77 C 7275 2P 112* M 54 x 8 -   10/20

301756

AN 77 C 7341 2P 112* M 32 x 8 -   10/20

301906

AN 77 D 7358 2P 112* M 32 x 8 -  ➞ 10/20

301757

AN 97 A 7391 2P 132* M 32 x 8 - ➞ ➞ 10/20

301758

AN 97 C 7257 2P 132* B 54 x 8 (4)   10/20

301920

(1) One-pipe pump - (2) Replaced by AN Kit - (3) Bleeding screw 1/4NPTF on the regulator side - (4) Long outlet nozzle (5) Shaft with 2 flat surfaces - (6) Kerosene - (7) Motor speed 3450tr/min - * with air jack outlet

Oil pump

CSB.162

Oi

l p

um

p

PO

(5)

ASSEMBLY

tanks to the flange, a pump with a 32mm hub Ø can be transformed into a flange pump (92mm) and a 54mm hub Ø.

✓Slide the flange on the hub pump with flat surface against pump surface

✓Screw the flange.

NOTE The flange bosses gives a hub Ø 54 mm

Types of Pumps replaced with a current pump and this flange

Current pump Ref + Adapter hub 32/54 + Flange hub 54 Replaced pump Replaced pump Ref AN 47 A 1326 301731 + 301310 AN 47 A 1326AN 47 A 7226 301731301042 + 301301 AN 47 A 7216 301041 AN 47 B 7327 301044 + 301310 AN 47 B 7327AN 47 B 7227 301044301043 + 301301 AN 47 B 7217 301732 AN 47 D 1339 301749 + 301310 AN 47 D 1339AN 47 D 7229 301749301048 + 301301 AN 47 D 7219 301047 AN 47 C 1342 301750 AN 47 C 1342 301750 AN 47 C 1342 301750 + 301310 AN 47 C 7228 301045 + 301301 AN 47 C 7218 301734

AE Range without SOLENOID VALVE

The SUNTEC AE oil pump is the basic model incorporating a pressure regulating valve. It does not have a cut-off features, to purge air, gas through the nozzle line.

Information AE

The AE 87 range is replaced by the AE77 range.

The flange 301301 and the adapter hub 301310 can be used with this range of AE pump

Type 2800 tr/mn Flow l/h to and 10 bars M=Hub B=Flange Ø=Shaft

Featu-res Rotation nozzle side PressureOutlet Ref

AE 35 C 9850 2P 40 M 32 x 8 (1)   4/18

301759

AE 45 C 1360 1P 40 M 32 x 8 -   7/14

301801

AE 45 C 1370 1M 40 M 32 x 8 (2)(4)   7/14

301802

AE 47 A 1384 1M 40 M 32 x 8 (4) ➞ ➞ 7/14

301800

AE 47 A 1384 1P 40 M 32 x 8 - ➞ ➞ 7/14

301761

AE 47 A 7384 3M 40* M 32 x 8 (4) ➞ ➞ 7/14

301762

AE 47 B 1366 1P 40 M 32 x 8 - ➞  7/14

301805

AE 47 B 7267 3P 40* M 54 x 8 - ➞  7/14

301763

AE 47 C 1386 1P 40 M 32 x 8 -   2/12

301803

AE 47 C 1387 1P 40 M 32 x 8 -   7/14

301799

AE 47 C 1394 1P 40 M 32 x 8 (5)   3/15

301764

AE 47 C 1397 1P 40 M 32 x 8 -   10/20 see 301799 AE 47 C 7368 3P 40* M 32 x 8 -   5/12

301804

AE 47 C 1393 1M 40 M 32 x 8 (4)(3)   0,5/3

301797

AE 47 D 1378 1M 40 M 32 x 8 (4)  ➞ 7/14

301768

AE 47 D 1385 1P 40 M 32 x 8 -  ➞ 5/20

301798

AE 57 B 1364 1M 50 M 32 x 8 (4) ➞  10/20

301769

AE 57 C 7373 3P 50* M 32 x 8 (1)   8/28

301806

AE 67 C 7285 3P 80* B 54 x 8 (3)   7/14

301812

AE 67 C 7361 3P 80* M 32 x 8 (1)   8/28

301810

AE 67 D 7278 3P 80* B 54 x 8 -  ➞ 7/14

301811

AE 77 B 7291 3P 112* M 54 x 8 - ➞  8/28

301774

AE 77 C 7270 2P 112* B 54 x 8 (3)(1)   10/28

301832

AE 97 C 7296 3P 132* B 54 x 8 (3)   8/28

301794

AE 97 C 7297 3P 132* B 54 x 8 (3)(6)   7/12

301795

AE 97 C 7390 2P 132* M 32 x 8 (3)   0,5/3

301839

AE 97 C 7390 2M 132* M 32 x 8 (4)(3)   0,5/3

301838

AE 97 D 7355 2P 132* M 32 x 8 -  ➞ 2/12

301807

AE 77 C 7270 2P 112* B 54 x 8 (3)(1)   10/28

301832

AE 77 C 7380 2P 112* B 32 x 8 (1)   10/20

301833

AE 97 C 7296 3P 132* B 54 x 8 (3)   8/28

301794

AE 97 C 7297 3P 132* B 54 x 8 (3)(6)   7/12

301795

AE 97 C 7390 2P 132* M 32 x 8 (3)   0,5/3

301839

AE 97 C 7390 2M 132* M 32 x 8 (4)(3)   0,5/3

301838

AE 97 D 7355 2P 132* M 32 x 8 -  ➞ 2/12

301807

(1) Pressure gauge port on the top - (2) Inlet 1/8" fem. Return 1/8" male - (3) Long outlet nozzle - (4) One-pipe pump (5) Shaft with 2 flat surfaces - (6) Kerosene - *with air jack outlet

Oil pump

Oi

l p

um

p

PO

(6)

AS Range with SOLENOID VALVE

The SUNTEC AS oil pump has a built in solenoid valve which controls the regulator cut-off valve giving fast cut-off and cut-on func-tion independent of the rotafunc-tional speed.

Information AS

The pumps in grey line can be used for the other pump replacements with adding flange or adapter hub. In this way you can decrease your stock and increase your possibilities of repair and maintenance.

Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

AS 47 A 1536 1P 0500 40 M 32 x 8 - ➞ ➞ 7/14

301082

AS 47 A 1536 6P 0500 40 M 32 x 8 (11) ➞ ➞ 7/14

301925

AS 47 A 1564 1P 0500 40 M 32 x 8 (4) ➞ ➞ 7/12

301808

AS 47 A 1588 1P 0500 40 M 32 x 8 (4)(10) ➞ ➞ 7/12 see 301815 AS 47 A 1590 1P 0200 40 M 32 x 8 (11) ➞ ➞ 7/14

301814

AS 47 A 1602 6P 0500 40 M 32 x 8 (4)(10) ➞ ➞ 7/12

301815

AS 47 A 7432 3P 0500 40 B 54 x 8 (5)(2)(8) ➞ ➞ 7/14

301081

AS 47 A 7436 3P 0500 40* M 54 x 8 - ➞ ➞ 7/14

301816

AS 47 A 7465 2M 0500 40* B 54 x 8 (8)(13)(2)(4) ➞ ➞ 7/12

301818

AS 47 A 7536 3P 0500 40* M 32 x 8 - ➞ ➞ 7/14

301819

AS 47 A 7564 3P 0500 40* M 32 x 8 (4) ➞ ➞ 7/12

301850

AS 47 A 7509 3P 0500 40* M 32 x 8 (1)(7)(8) ➞  7/16

301852

AS 47 B 1537 6P 0500 40 M 32 x 8 - ➞  7/14

301084

AS 47 B 1537 1P 0260 40 M 32 x 8 (11) ➞  7/14

301928

AS 47 B 1537 1P 0310 40 M 32 x 8 (15) ➞  7/14

301929

AS 47 B 1605 1P 0500 40 M 32 x 8 (10) ➞  7/14

301822

AS 47 C 1538 6P 0500 40 M 32 x 8 -   7/14

301086

AS 47 C 1538 (110V) 40 M 32 x 8 (3)   7/14

301090

AS 47 C 1538 1P 0200 40 M 32 x 8 (11)   7/14

301932

AS 47 C 1554 1P 0500 40 M 32 x 8 (4)(9)   7/12

301846

AS 47 C 1569 1P 0500 40 M 32 x 8 -   7/14 see 301086 AS 47 C 1578 1P 0500 40 M 32 x 8 -   7/25 see 301829 AS 47 C 1581 1P 0500 40 M 32 x 8 (4)   7/12 see 301846 AS 47 C 1582 1P 0500 40 M 32 x 8 (4)(14)   7/12

301826

AS 47 C 1587 1P 0500 40 M 32 x 8 (4)(1)   7/25

301827

AS 47 C 1601 1P 0500 40 M 32 x 8 -   7/14 see 301086 AS 47 C 1603 3P 0500 40 M 32 x 8 -   7/14 see 301086 AS 47 C 1604 6P 0500 40 M 32 x 8 (10)   7/25

301829

AS 47 C 1607 1P 0500 40 M 32 x 8 (9)(10)   7/12 see 301846 AS 47 C 7434 3P 0500 40 B 54 x 8 (5)(2)(8)   7/14

301841

AS 47 C 7434 3P 0260 40* B 54 x 8 (11)(2)(8)   7/14

301933

AS 47 C 7438 3P 0500 40 M 54 x 8 (6)   7/14

301843

AS 47 C 7444 3P 0500 40 B 54 x 8 (5)(2)   7/14

301085

AS 47 C 7451 3M 0500 40* B 54 x 8 (8)(12)(2)(4)   7/12

301848

AS 47 C 7461 3P 0500 40* B 54 x 8 (2)(8)   10/20

301845

AS 47 C 1538 6P 0500 40 M 32 x 8 -   7/14

301086

AS 47 C 7554 3P 0500 40* M 32 x 8 (4)   7/12 see 301846 AS 47 D 1539 1P 0500 40 M 32 x 8 -  ➞ 7/14

301088

AS 47 D 1550 1P 0500 40 M 32 x 8 -  ➞ 7/25

301083

AS 47 D 1557 1P 0500 40 M 32 x 8 (1)  ➞ 7/22

301849

AS 47 D 1562 1P 0500 40 M 32 x 8 (4)  ➞ 7/12

301836

AS 47 D 1586 1P 0500 40 M 32 x 8 (1)(4)  ➞ 7/25

301840

AS 47 D 1596 1P 0500 40 M 32 x 8 -  ➞ -

301079

AS 47 D 1596 + vis 40 M 32 x 8 -  ➞ -

406021

AS 47 D 1597 1M 0500 40 M 32 x 8 (4)  ➞ 7/12

301842

AS 47 D 1580 1P 0500 40 M 32 x 8 (7)  ➞ 7/14

301080

AS 47 D 7435 3P 0500 40 B 54 x 8 (5)(2)(8)  ➞ 7/14

301087

AS 47 D 7439 3P 0500 40 M 54 x 8 (5)  ➞ 7/14

301844

Oil pump

CSB.164

Oi

l p

um

p

PO

(7)

AS Range with SOLENOID VALVE

(continuation)

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

AS 57 A 7591 3P 0500 40* M 32 x 8 - ➞ ➞ 7/14

301855

AS 57 B 1585 1P 0500 40 M 32 x 8 - ➞  7/14

301856

AS 57 C 1544 1P 0500 58 M 32 x 8 -   7/14

301091

AS 57 C 1583 1P 0500 58 M 32 x 8 (5)   7/12

301858

AS 57 C 7441 3P 0500 58 B 54 x 8 (6)(3)(9)   7/14

301093

AS 67 A 7463 3P 0500 82* B 54 x 8 (3) ➞ ➞ 10/15

301865

AS 67 A 7466 3P 0500 82* B 54 x 8 (3)(9) ➞ ➞ 10/15

301866

AS 67 B 1575 1P 0500 82 M 32 x 8 - ➞  10/15

301863

AS 67 B 7449 3P 0500 82* B 54 x 8 (3)(9) ➞  10/15

301868

AS 67 C 1570 1P 0500 82 M 32 x 8 -   10/15

301862

AS 67 C 7446 3P 0500 82* M 54 x 8 (5)   10/14

301860

AS 67 C 7456 3P 0500 82* B 54 x 8 (3)(9)   10/15

301861

(1) Shaft with 2 flat surfaces

(2) Type with flange - (3) 110 VAC - (4) Kerosene type- (5) Replaced by AS kit - (6) Outlet nozzle with flare nipple (7) Inlet and return 1/8 - (8) Long outlet nozzle - (9) Adjusting pressure screw 4mm BTR - (10) Direct sealing inlet and return (11) 24 VAC - (13) Inlet 1/4NPTF on the regulator side - (12) One-pipe pump - (13) Inlet steel plug

(14) Pressure gauge port on the nozzle side - (15) 24 VDC - * With air jack outlet.

Changing KIT FROM AS pump to AN pump

ASSEMBLY

Cut-off fuel oil inlet and power supply too. Disconnect the coil.

Remove the coil "A"

Remove the plate "B"

Remove the coil tube "C"

Put the kit "D" on the pump

Put the plate "B" on the pump

✓Start the burner and check for leaks

Note : SUNTEC accepts no liability with consequences of wrong assembly or wrong use of this kit.

This kit can only be used for changing AS pump to AN pump.

Changing example :

AS 47 C 7536 to AN 47 A 7326 AS 47 C 7538 to AN 47 C 7342

Current pump Ref + Adapter hub 32/54 + Flange hub 54 Replaced pump Replaced pump ref AN 47 A 1536 301082 + 301301 AN 47 A 7536AN 47 A 7432 301082301081 AN 47 C 1538 301086 AN 47 C 7538 301086 + 301310 AN 47 C 7438 301843 + 301301 AN 47 C 7434 301841 + 301301 AN 47 C 7444 301085

AT Range with 2 SOLENOID VALVES

The SUNTEC AT2 oil pump features a two mode pressure operation and incorporates a blocking solenoid valve with in-line cut-off function. Switching between low and high modes is ensured by a second integral solenoid valve.

The SUNTEC AT3 oil pump incorporates in addition a pressure gauge on the cover for checking high pressure nozzle or pressure return in low pressure function. Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

AT2 45 A 9547 2P 0500 46* M 32 x 8 (2) ➞ ➞ 8/25

301132

AT2 45 C 9541 2P 0500 46* M 32 x 8 (2)   8/25

301120

AT2 45 C 9563 2P 0500 46* M 32 x 8 (1)(2)   8/25

301122

AT2 45 D 9538 4P 0500 46* M 32 x 8 -  ➞ 8/25

301005

AT2 45 D 9544 2P 0500 46* M 32 x 8 (2)  ➞ 8/25

301121

AT2 45 D 9555 2P 0500 46* M 32 x 8 (2)  ➞ 8/25

301121

AT2 55 C 9549 2P 0500 65* M 32 x 8 (2)   8/25

301125

AT2 55 C 9572 2P 0500 65* M 32 x 8 (2)(4)   8/25

301903

AT2 65 A 9577 2P 0500 87* M 32 x 8 (2) ➞ ➞ 8/25

301126

AT2 65 B 9587 2P 0500 87* M 32 x 8 (2) ➞  8/25

301907

AT2 65 D 9582 2P 0500 87* M 32 x 8 (2)(5)  ➞ 2/15

301910

(1) Inlet and return 1/8" - Outlet nozzle with male nipple 1/8" for pipe Ø 4 - (2) Flow indication in high pressure function (3) Inlet and return M16 - (4) Proofed at 28 bars - (5) Kerosene - * With air jack outlet

Oil pump

Oi

l p

um

p

PO

(8)

AT Range with 2 SOLENOID VALVES

(continuation)

The SUNTEC AT2 oil pump features a two mode pressure operation and incorporates a blocking solenoid valve with in-line cut-off function. Switching between low and high modes is ensured by a second integral solenoid valve.

The SUNTEC AT3 oil pump incorporates in addition a pressure gauge on the cover for checking high pressure nozzle or pressure return in low pressure function. Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

AT2 95 B 9592 2P 0500 132* M 32 x 8 (2) ➞  8/25

301775

AT2 95 C 9585 2P 0500 132* M 32 x 8 (2)(3)   8/25

301777

AT3 45 A 9559 2P 0500 46* M 32 x 8 (2) ➞ ➞ 8/25

301133

AT3 45 C 9558 2P 0500 46* M 32 x 8 (2)   8/25

301135

AT3 45 D 9546 2P 0500 46* M 32 x 8 (2)  ➞ 8/25

301130

AT3 45 B 9575 2P 0500 46* M 32 x 8 (2) ➞  8/25

301134

AT3 55 C 9550 2P 0500 65* M 32 x 8 (2)   8/25

301131

AT3 55 D 9564 2P 0500 65* M 32 x 8 (2)  ➞ 8/25

301778

(1) Inlet and return 1/8" - Outlet nozzle with male nipple 1/8" for pipe Ø 4 - (2) Flow indication in high pressure function (3) Inlet and return M16 - (4) Proofed at 28 bars - (5) Kerosene - * With air jack outlet

AP Range with 2 MODE PRESSURE SOLENOID VALVES

Delivered without connector

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

AP 47 A 1593 1P 0500 40 M 32 x 8 (1)(2)(3) ➞ ➞ 3/28

301100

AP 47 B 7561 3P 0500 40* M 32 x 8 - ➞  3/28

301099

AP 47 C 7460 3P 0500 40* B 54 x 8 (2)(4)   3/28

301097

AP 47 C 7556 3P 0500 40* M 32 x 8 -   3/28

301098

AP 57 A 7549 3P 0500 58* M 32 x 8 - ➞ ➞ 3/28

301095

AP 57 C 7545 3P 0500 58* M 32 x 8 -   3/28

301092

AP 67 C 7559 3P 0500 82* M 32 x 8 -   5/28

301109

AP2 45 C 9560 1P 0500 46* M 32 x 8 -   8/25

301782

AP2 45 D 9566 1P 0500 46* M 32 x 8 -  ➞ 4/25

301941

AP2 65 B 9523 1P 0500 87* M 32 x 8 - ➞  4/25

301783

AP2 95 C 9590 1P 0500 132* M 32 x 8 -   8/25

301943

AP3 45 C 9510 1P 0500 46* M 32 x 8 -   4/25

301101

(1)Inlet/Return G18 - (2)Long outlet nozzle- (3)Special outlet nozzle plug - (4) Type with flange -* With air jack outlet.

The SUNTEC AP oil pump has a built-in solenoid valve which provides a two-mode pressure operation. AP2 and AP3 ranges are from the same technology as AT2 x AT3 ranges, but without in-line cut-off function.

D Range without SOLENOID VALVE

The SUNTEC D oil pump is specially adapted for heavy oil. This pump incorporates a pressure regulator without in-line cut-off function. For oil flow 45 to90 l/h (2850 tr/mn - 20 cSt - 20 bars) viscosity 2 to 200 cSt.

The new revision 3 of the range D incorporates an antiabrasion plate in the gear for more efficiency.

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation

Outlet

nozzle side Pressure Ref

D 45 B 7347 3P 54 M 32 x 8 (3) ➞  10/28

301114

D 45 B 7388 3P 54 M 32 x 8 (8) ➞  0,5/3

301786

D 45 C 7281 3P 54 B 54 x 8 (4)(2)(5)(6)   10/28

301119

D 47 A 7383 3P 54 M 32 x 8 (7)(8) ➞ ➞ 7/25

301116

D 47 D 7352 3P 54 M 32 x 8 (7)(11)  ➞ 10/28

301787

D 57 C 7372 3P 72 M 32 x 8 (6)(9)   10/28

301111

D 67 A 7276 3P 97 B 54 x 8 (2)(4)(5) ➞ ➞ 10/28

301117

D 67 A 7280 3P 97 M 54 x 8 (1)(7)(10) ➞ ➞ 16/28

301118

D 67 C 7284 3P 97 B 54 x 8 (1)(5)(8)   10/28

301792

(1) Cover with hole for heater element (Type with in-line cut-off function) - (2) Cover vacuum gauge port G 1/4" on regulator side (3) Body vacuum gauge port G 1/8" on regulator side - (4) Long outlet nozzle - (5) Type with flange - (6) With air jack outlet on the top - (7) In-line cut-off function- (8) Cover vacuum gauge port G 1/8" on regulator side - (9) Cover vacuum gauge port G 1/8" on outlet nozzle side - (10) Inlet on cover (11) Inlet and return M14

Oil pump

CSB.166

Oi

l p

um

p

PO

(9)

J Range without SOLENOID VALVE

The SUNTEC J oil pump incorporates a pressure regulating valve with cut-off function except the J oil pump 1002. The J oil pump is

adapted for heavy oil 2,8 to 200 cSt. The J oil pumps range 1000 are built with conical threads. The J oil pump range 1000 and 1001 incorporate an in-line cut-off function. The J oil pump range 1002 are built without in-line cut-off function.

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation nozzle side PressureOutlet Ref

J3 CAB 1000 3P 90 B 54 x 11,11 (3) ➞ ➞ 7/14 see

301011

J3 CBB 1000 3P 90 B 54 x 11,11 (3) ➞  7/14 see

301012

J3 CCB 1000 3P 90 B 54 x 11,11 (3)   7/14 see

301013

J3 CDB 1000 3P 90 B 54 x 11,11 (3)  ➞ 7/14 see

301014

J4 CAC 1000 5P 110 B 54 x 11,11 (3) ➞ ➞ 10/21

301011

J4 CBC 1000 5P 110 B 54 x 11,11 (3) ➞  10/21

301012

J4 CCC 1000 5P 110 B 54 x 11,11 (3)   10/21

301013

J4 CDC 1000 5P 110 B 54 x 11,11 (3)  ➞ 10/21

301014

J6 CAC 1000 5P 205 B 54 x 11,11 (1)(3) ➞ ➞ 10/21

301021

J6 CAC 1002 5P 205 B 54 x 11,11 (1)(4)(3) ➞ ➞ 10/21

301917

J6 CBC 1000 5P 205 B 54 x 11,11 (1)(3) ➞  10/21

301022

J6 CCC 1000 5P 205 B 54 x 11,11 (1)(3)   10/21

301023

J6 CCC 1002 5P 205 B 54 x 11,11 (1)(3)(4)   10/21

301918

J6 CDC 1000 5P 205 B 54 x 11,11 (1)(3)  ➞ 10/21

301024

J6 CAC 1001 5P 205 B 54 x 11,11 (1)(3) ➞ ➞ 10/21

301025

J6 CCC 1001 5P 205 B 54 x 11,11 (1)(3)   10/21

301026

J7 CAC 1001 4P 300 B 54 x 11,11 (2)(3) ➞ ➞ 10/21

301181

J7 CCC 1001 4P 300 B 54 x 11,11 (2)(3)   10/21

301183

J7 CCC 1002 4P 300 B 54 x 11,11 (2)(3)(4)   10/21

301919

(1) J6 pump replaces H6 pump - (2) J7 replaces H7 pump - (3) Type with flange - (4) Without in-line cut-of function

Note :

Range 1000 = Inlet and return 1/4" - Outlet nozzle 1/8" Range 1001 = Inlet and return 1/2G - Outlet nozzle 1/4" gas.

AJ Range without SOLENOID VALVE CAN REPLACE J PUMPS

The SUNTEC AJ oil pump is the basic model incorporating a pressure regulating valve with cut-off. This range has the same shaft and hub sizes as J and H pumps and can replace these types.

The AJ oil pump type 1000 and 1003 incorporates an in-line off function. The AJ oil pump type 1002 is built without in-line cut-off function.

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation nozzle side PressureOutlet Ref

AJ4 AC 1000 2P 110 B 54 x 11,11 (1) ➞ ➞ 10/20

301601

AJ4 CC 1000 2P 110 B 54 x 11,11 (1)   10/20

301611

AJ4 DC 1000 3P 110 B 54 x 11,11 (1)  ➞ 10/20

301613

AJ4 CE 1002 2P 110 B 54 x 11,11 (1)(3)   10/30

301612

AJ6 AC 1000 2P 200 B 54 x 11,11 (1) ➞ ➞ 10/20

301651

AJ6 CC 1000 3P 200 B 54 x 11,11 (1)   10/20

301661

AJ6 CC 1003 2P 200 B 54 x 8 (1)(2)   10/20

301663

AJ6 CE 1002 3P 200 B 54 x 11,11 (1)(3)   10/30

301664

AJ6 DC 1000 2P 200 B 54 x 11,11 (1)  ➞ 10/20

301671

(1) Type with flange - (2) Special type with shaft Ø 8 - (3) Without in-line cut-off function

E Range without SOLENOID VALVE FOR MEDIUM FUEL OIL

The SUNTEC E oil pump incorporates a pressure regulating valve with cut-off function. This range can be used with medium and light oil. The SUNTEC E oil pump type 1069 is built with a drilling to accept a heating preheater (temp. max. 120°C). With pressure regulator 14 to 30 bars.

The SUNTEC E type 1001 incorporates an in-line cut-off function. The SUNTEC E type 1069 are built without in-line cut-off function.

Type Flow l/h to 2800 tr/ mn and 10 bars M=Hub B=Flange

Ø=Shaft Features Rotation nozzle side PressureOutlet Ref

E4 NA 1001 6P 130 B 54 x 11,11 (3)(4) ➞ ➞ 14/30

301151

E4 NA 1069 6P 130 B 54 x 11,11 (3)(4)(5)(6) ➞ ➞ 14/30

301152

E4 NC 1001 6P 130 B 54 x 11,11 (3)(4)   14/30

301153

E4 NC 1069 6P 130 B 54 x 11,11 (3)(4)(5)(6)   14/30

301155

(1) Used for OERTLI E6CC and E7CC - (2) Strainer 170µm - (3) Strainer 550µm - (4) Type with flange - (5) Without in-line cut-off function - (6) Cover with hole for heating element

NOTE : All these pumps incorporate a flange.

Oil pump

Oi

l p

um

p

PO

(10)

E Range without SOLENOID VALVE FOR MEDIUM FUEL OIL

(continuation)

The SUNTEC E oil pump incorporates a pressure regulating valve with cut-off function. This range can be used with medium and light oil. The SUNTEC E oil pump type 1069 is built with a drilling to accept a heating preheater (temp. max. 120°C). With pressure regulator 14 to 30 bars.

The SUNTEC E type 1001 incorporates an in-line cut-off function. The SUNTEC E type 1069 are built without in-line cut-off function.

Type 2800 tr/mn Flow l/h to and 10 bars

M=Hub B=Flange

Ø=Shaft Features Rotation nozzle side PressureOutlet Ref

E6 NA 1001 6P 228 B 54 x 11,11 (3)(4) ➞ ➞ 14/30

301161

E6 NA 1069 6P 228 B 54 x 11,11 (3)(4)(5)(6) ➞ ➞ 14/30

301145

E6 NA 1070 6P 228 B 54 x 11,11 (3)(4)(6) ➞ ➞ 16/28

301922

E6 NB 1001 5P 228 B 54 x 11,11 (3)(4) ➞  14/30

301162

E6 CC 1001 6P 228 B 54 x 11,11 (1)(2)(4)   14/30

301166

E6 NC 1001 6P 228 B 54 x 11,11 (1)(3)(4)   14/30

301163

E6 NC 1069 6P 228 B 54 x 11,11 (3)(4)(5)(6)   14/30

301165

E6 ND 1001 6P 228 B 54 x 11,11 (3)(4)  ➞ 14/30

301164

E7 NA 1001 5P 340 B 54 x 11,11 (3)(4) ➞ ➞ 14/30

301171

E7 NA 1069 5P 340 B 54 x 11,11 (3)(4)(5)(6) ➞ ➞ 14/30

301170

E7 CC 1001 5P 340 B 54 x 11,11 (2)(4)   14/30

301174

E7 NC 1001 5P 340 B 54 x 11,11 (1)(3)(4)   14/30

301173

E7 NC 1069 5P 340 B 54 x 11,11 (3)(4)(5)(6)   14/30

301175

(1) Used for OERTLI E6CC and E7CC - (2) Strainer 170µm - (3) Strainer 550µm - (4) Type with flange - (5) Without in-line cut-off function - (6) Cover with hole for heating element

NOTE : All these pumps incorporate a flange.

TA Range with PRESSURE REGULATOR for LIGHT and HEAVY FUEL OIL

For light and heavy fuel oil, viscosity mini 4 cSt, maxi 800 cST, temperature 140°C at 40 bars except T5 and TA5 : 30 bars.

New : Carbon oxyde deposit on the gear surface, autolubricant carbon bearing. Sintered iron crescent replaces bronze crescent for better resistance to heavy fuel oil. With pressure regulator.

Type 2800 tr/mn and Flow l/h to 10 bars

M=Hub B=Flange

Ø=Shaft Rotation Pressure Ref

TA2 A 4010 5 500 B 54 x 12* ➞ 7/40

301270

TA2 C 4010 5 500 B 54 x 12*  7/40

301271

TA3 A 4010 5 750 B 54 x 12* ➞ 7/40

301272

TA3 C 4010 5 750 B 54 x 12*  7/40

301273

TA4 A 4010 5 1000 B 54 x 12* ➞ 7/40

301274

TA4 C 4010 5 1000 B 54 x 12*  7/40

301275

TA5 C 3010 5 1350 B 54 x 12*  7/30

301277

Hub Ø 54, entraxe flange : 125mm - Shaft Ø 12mm - *With flange

NOTE : This range of pump may be fitted with a preheater.

T Range without REGULATOR for LIGHT and HEAVY FUEL OIL

Type 2800 tr/mn and Flow l/h to 10 bars

M=Hub B=Flange

Ø=Shaft Rotation Pressure Ref

T2 C 105 1400 B 70 x 20 (1)  Maxi 40

301251

T3 A 105 2000 B 70 x 20 (1) ➞ Maxi 40

301252

T3 C 105 2000 B 70 x 20 (1)  Maxi 40

301253

T4 A 105 2780 B 70 x 20 (1) ➞ Maxi 40

301254

T4 C 105 2780 B 70 x 20 (1)  Maxi 40

301255

(1) With flange - Without pressure regulator. Hub Ø 70, entraxe flange : 150mm - Shaft Ø 20mm - Range 104 replaced by 105

NOTE : This range of pump may be fitted with a preheater. No adjusting screw. Maxi pressure 30 bars.

Oil pump

CSB.168

Oi

l p

um

p

PO

(11)

SUNTEC

PUMP

- SUNDSTRAND

FUEL

SUNDSTRAND

PUMP IDENTIFICATION TABLE

A

AM

SUNDSTRAND

A60 Type capacity l/hnozzle Strainer Rotation Pressure range bar Fixing without nozzle Hub meaningwithout

A : Normal 1 = 18 A = without A = Right L = 5 - 10 1 = Flange 0 or 1 1 = Ø 32 0 to 9

AM : with EV 2 = 25 Z = without C =Left M = 7 - 14 2 = Hub 2 = Ø 54

3 = 15 P = 10 - 18 4 = Ø 54

Example ➩ A 2 Z C M 2 0 1 4

Example for replacement : A2ZCM2014 is replaced by AN 47C 7328 ref 301750

SUNTEC

PUMP IDENTIFICATION TABLE

AN

AS

AP - AL

AT

SUNTEC Type Flow 2800 tr/mn 10 bars Rotation

Outlet nozzle

side Hub

Ø

Inlet/return Range Voltage Cable

A = FOD cut-off solenoid L = with in line valve 35 = 40l/h A = right right 2-7-8 = 1/4" Revision N° P = Screw by pass plugged 01 = 110V 00 = without25 = 25 cm 65 = 82l/h B = right left 95 = Ø32 4 = 1/8" 02 = 24V 35 = 35 cm 45 = 45 cm

C = left left Bleed pipe 05 = 220V 60 = 60 cm

D = left right 10 = 1m

Example AL 35 A 95 2 8 1 P 05 35

SUNTEC Type Flow 2800 tr/mn

10 bars Rotation

Outlet

nozzle side Range Hub meaningwithout

A = FOD AN = without solenoid valve 47 = 40l/h A = right right 7 = 1970 2 = Ø54

2 digits Revision N°

P = Screw bypass plugged D = without solenoid valve 57 = 58l/h B = right left 1 = 1992 3 = Ø32

AE = Pressure regulator

without in line cut-off 67 = 80l/h C = left left 1 = For same models 7 = with

4 = Ø54 AS = with solenoid valve 77 = 110l/h D = left right 5 = Ø32 AP = with solenoid valve

2 stages 97 = 130l/h lateral pressureport

AT2 2 stages with in line cut-off 45 = 45l/h A = right right 1 = withoout 95 = Ø32 AT3 same as AT2 + pressure

plug on cover B = right left C = left left D = left right Example AS 57 C 7 4 41 3 P

AJ

J and E

T

TA

SUNTEC Type Flow 2800 tr/mn

10 bars Rotation

Outlet nozzle

side Pressurein bar Flange Features

AJ = FOD 4 = 110l/h A = right right C - 10 to 20 1 = with 000 = standard

Revision N°

P = Screw bypass plugged 6 = 200l/h C = left left E - 10 to 30 + Hub 002 = Pierced nozzle, outlet no cut-off

D = left right Ø54 003 = shaft Ø8 without off

Example AJ 6 D C 1 003 2 P

SUNTEC Type Flow 2800 tr/mn

10 bars Filter Rotation Outlet no-zzle side

Pressure

in bar Flange Features

J = FOD 3 = 90l/h C A = right right B - 7 to 14 1 = with 000 = 1/2 conic

Revision

N° P = Screw bypass plugged 4 = 110l/h B = right left C - 10 to 21

6 = 205l/h C = left left K - 14 to 30 001 = 1/2 cylindric

7 = 300l/h D = left right Example J 3 C B B 1 000 4 P

Oil pump

Oi

l p

um

p

PO

(12)

SUNTEC

PUMP IDENTIFICATION TABLE

(continuation)

AJ

J and E

T

TA

SUNTEC Type Flow 2800 tr/mn15 bars to 20cst Filter Rotation Outlet nozzle side Flange Features

E = FL 4 = 130l/h C = 170mM A = right right 10 = with 01 = standard

Revision

N° P = Screw bypass plugged

6 = 228l/h B = right left 69 = Cover with hole for

heating element

7 = 340l/h C = left left

N = 550mM D = left right

Example E 4 N C 10 69 5 P

SUNTEC Type Flow 2800 tr/mn10 bars Rotation Pressure Features

TA = FL or FOD 2 = 500l/h A = right 30 = 7 to 30 bar

10 = Cover with hole for heating element Revision N° 3 = 760l/h C = left 40 = 7 to 40 bar

4 = 1000l/h 5 = 1360l/h

Example TA 2 C 40 10 5

T = FL or FOD 2 = 1400l/h A = right

10 = Cover with hole for heating element Revision N° 3 = 2000l/h C = left

4 = 2900l/h 5 = 3950l/h

Example T 4 C 10 5

SUNTEC

PUMP ACCESSORIES

SHAFT SEAL REPAIR KIT

Description Mark Ref

AN - AS - AE - AL - AT - D - AP - A2L type (SUNTEC ref. 991515/991511)

1

301391

AJ type (SUNTEC ref. 270202)

1

301342

J - H - E 1000/1001 type (SUNTEC ref. 993473)

2

301340

E 1063/1069 type (SUNTEC ref. 132632)

2

301362

T type Revision 3 Shaft seal kit (SUNTEC ref. 991911)

3

301383

T type Revision 4/5 Shaft seal kit (SUNTEC ref. 1914462)

3

301380

TA type Revision 2/4/5 Shaft seal kit(SUNTEC ref. 2014462)

3

301381

Shaft E4 type 1063/1069(SUNTEC ref. 993009)

4

301363

Shaft E6 - E7 type 1063/1069 (SUNTEC ref. 993010)

4

301364

Shaft seal wrench Ø 4mm entraxe 25mm J - H - E (SUNTEC ref. 27005)

5

301370

COVER GASKET

Description Mark Ref

AJ gasket (original piece) (SUNTEC ref. 270112)

1

301436

AJ gasket (adaptable piece)

1

301435

AJ gasket (original piece)

1

301437

J - H - E gasket (original piece) (SUNTEC ref. 110441/135803)

2

301411

J - H - E gasket (adaptable piece)

2

301410

J - H - E gasket (original piece)

2

301412

A1 - A2 gasket

3

301420

AN - AS - AE - AL - AP - AT gasket (SUNTEC ref. 3759811/991523)

AN/AE/AS/AP 47-57-67 range 7000 rev.2 cast cover - AN/AE 77-97 range 7000 rev.2 cast cover AN/AE/AS/AP 47-57-67 range 7000 rev.3 and 5 - AN/AE/AS/AP 47-57-67 range 1000 rev.1 and 5 - AL/ALE/A2L/AR 35-55-65 range 9000 revision 1-2-5 - AT2/AT3 45-55-65 range 9000 revision 1-2-5 - AP2/AP3 45-55-65 range 9000 revision 1 - AN/AE 77-97 range 7000 revision 3 -

AL/A2L/AR/AT2 75-95 range 9000 revision 2 and 5 - AP2 75-95 range 9000 revision 1 -

new aluminium cover 82 (width 0,65mm)(original piece)

4

301433

AN - AS - AE - AL - AP - AT gasket (SUNTEC ref. 3759811/991523)

AN/AE/AS/AP 47-57-67 range 7000 rev.2 cast cover - AN/AE 77-97 range 7000 rev.2 cast cover AN/AE/AS/AP 47-57-67 range 7000 rev.3 and 5 - AN/AE/AS/AP 47-57-67 range 1000 rev.1 and 5 - AL/ALE/A2L/AR 35-55-65 range 9000 rev.1-2-5 - AT2/AT3 45-55-65 range 9000 rev.1-2-5 - AP2/AP3 45-55-65 serie 9000 rev.1 - AN/AE 77-97 range 7000 rev.3 -

AL/A2L/AR/AT2 75-95 serie 9000 rev.2 and 5 - AP2 75-95 range 9000 rev.1

new aluminium cover 82 (width 0,65mm) (adaptable piece)

4

301432

1

2

3

4

x 12 x 10 x 12 x 10 x 12 x 10 x 12

1

2

3

4

5

Oil pump

CSB.170

Oi

l p

um

p

PO

(13)

COVER GASKET

(continuation)

Description Mark Ref

AN - AS - AE - AP gasket (SUNTEC ref. 991524)

AN/AE/AS/AP 47-57-67 range 7000 rev.4 and 6 fl ate cover - AN/AE/AS/AP 47-57-67 range 1000 rev.4 and 6

fl ate cover - AL/ALE 35-55-65 range 9000 rev.4 and 6 - AT2/AT3 45-55-65 range 9000 rev.4 and 6 -

AP2/AP3 45-55-65 range 9000 rev.4 et 6 - new fl ate cover (original piece) x 10

-

301434

cover Kit AN - AS - AE - AL - AP - AT rotation A-D

(range 35-45-55-65-47-57-67 Rev 2-3) (SUNTEC ref. 991475)

5

301580

cover Kit AN - AS - AE - AL - AP - AT rotation B-C

(range 35-45-55-65-47-57-67 Rev 2-3) (SUNTEC ref. 991476)

5

301581

cover Kit AN-AE-AP2-AT2-AL-ALE-A2L-AR rotation B-C

(range 75-95-77-97 Rev 3) (SUNTEC ref. 991509)

5

301582

STRAINER PUMP

Description Mark Ref

AN/AS/AE/AP range 47-57-67 range 7000 rev.3-4-5-6 aluminium cover (SUNTEC ref. 3715741)

2

301561

AN/AS/AE/AP 47-57-67 range 1000 rev.1-4-5-6 without bosses - AL/ALE/A2L/AR/AT2/AT3/AP2/AP3

range 9000 rev.1-2-4-5-6 (SUNTEC ref. 3715741)

2

301561

AN/AE 77-97 range 7000 revision 2 (SUNTEC ref. 3715732)

3

301563

A1/A2/AN/AS/AE/AP range 47-57-67 rev. 2 (SUNTEC ref. 3715735/3715732)

3

301563

AJ 39 mm (SUNTEC ref. 270087)

4

301565

J - H - E Filter "C" - 170µ 55mm (SUNTEC ref. 134423)

4

301540

E Filter "N"-550µ SUNTEC (ref. 134433)

4

301550

AP2 - AT2 75 and 95 (SUNTEC ref 3715750)

-

301566

D revision 3 (SUNTEC ref. 3715747)

-

301567

SOLENOID KIT

Description Mark Ref

Solenoid kit All AS types 220 volts (SUNTEC ref. 991435)

1

301470

Solenoid kit All AS types 110 volts (SUNTEC ref. 991431)

1

301473

Solenoid kit All AP types 220 volts for 47/57/67 (SUNTEC ref. 991455)

1

301472

Solenoid kit All AL types 220 volts revision 2 - 4 - 5 - 6 (SUNTEC ref. 3713798/991502)

1

301468

Solenoid kit All AT types rot.A/D revision 2 (SUNTEC ref. 3713798/991503)

2

301466

Solenoid kit AP 2/3 rot.B/C (SUNTEC ref. 991489)

2

301474

SOLENOID VALVE COIL

Description Ref

Solenoid valve coil 220 volts (SUNTEC ref. 3713798)

301478

Solenoid valve coil 110 volts (SUNTEC ref. 3713797)

301479

Solenoid valve coil 24 volts (SUNTEC ref. 3713796)

301477

Solenoid valve coil 24 volts continuous (SUNTEC ref. 3713818)

301481

SOLENOID VALVE CONNECTOR

Description Ref

AMP moulded connector with 3 leads 0.40m, for Rapa valve and SUNTEC solenoid valves

803030

AMP moulded connector with 3 leads 0,80m, for Rapa valve and SUNTEC solenoid valves

803029

AMP moulded connector for Rapa valve and SUNTEC solenoid valves

803034

CHANGING KIT PUMP - BY PASS PLUG

Description Ref

Changing AU pump kit to AE pump (SUNTEC ref.991401)

301589

Changing AS pump kit to AN pump (SUNTEC ref.991400)

301590

By-pass plug for AN-AS-AL-AP-AT-D pump (SUNTEC ref.3779858)

301469

5

1

2

4 x 6 x 6 x 1 x 6

Oil pump

Oi

l p

um

p

PO

(14)

FLANGE AND ADAPTER HUB

Description Mark Ref

Flange with 2 holes entraxe 92 mm (SUNTEC ref.132752)

1

301300

Flange for changing hub 32mm without fl ange to hub 54mm with fl ange

(SUNTEC ref.3719003)

2

301301

Adapter Hub to obtain hub

ø

54 mm with hub

ø

32 mm

(SUNTEC ref.3759833)

3

301310

Shaft Extension to obtain

ø

11,11 with shaft

ø

8 mm

(SUNTEC ref.3754737)

4

601130

ELECTRIC PREHEATER AND REGULATOR

Description Mark Ref

Electric preheater for heavy fuel oil cover pump type E 1069 T/TA

1

404956

Regulator kit for pump J 1069 T/TA (SUNTEC ref.991410)

2

301450

Low pressure regulator replaces only on AJ pump, Revision 2 only, the original regulator to get an adjusting

range 0,7 to 3 bars (SUNTEC ref.270716)

3

301452

Low pressure regulator replaces on AN-AS-AE-AL-AT-AP pump, revision 2 only, the original regulator to get an

adjusting range for 0,7 to 3 bars (SUNTEC ref.991500)

3

301453

ATCO - FRANCIA - SICMA

PUMP

RANGE of PUMP REPLACED by

SUNTEC

Range P4 - M7 - M9 - M11 - M13 - M15. This pump is not yet manufactured. Replaced by SUNTEC pump with same technical features...

Type Flow l/h to 2800 tr/mn & 10 bar Ø Hub and shaft in mm Characte-ristic RotationNozzle outlet Ref

P4 - LL 28 M 32x8  

301750

P4- RL 28 M 32x8 ➞ 

301044

P4 - LL Sib or PV4 with solenoid valve 28 M 32x8  

301088

P4 - RL Sib or PV4 with solenoid valve 28 M 32x8 ➞ 

301084

M15 - R15 170 B 54x11.11 (1)(2) ➞ ➞

301604

M15 - L15 (2)  

301605

(1) With fl ange - (2) Delivered with adapter kit

Nota : These pumps replace ATCO pumps, not fi tted with ring for air fl ap

DANFOSS

PUMP

DANFOSS

PUMPS IDENTIFICATION TABLE

RS

MS

MS21

BFP

DANFOSS Type Rotation Flow to 2800 tr/mnAdjustment 10 bars Size shaft By-pass screw

RS without EV 43 = 12l/h 2-3 = Ø8

RSA without EV right left 31 = 32l/h 0 = no plugged

RSH without EV 53 = 45l/h 0-3-5-7 = Ø10

RSL without EV 070 070L 32 = 75l/h 2 = plugged

RSLB without EV 33 = 100l/h 1-4-6-8 = Ø11,11

Example ➩ RS 60 070L 33 6 2

MSLA with EV right left

MSLB without EV 071B0 071B1 032 = 24l/h 10 or 20 = Ø8 2-4-6-8 = plugged

MSLC without EV 071B2 071B3 050 = 52l/h hub Ø32 1-3-5-7 = no plugged

071B4 071B5 Example ➩ MSLB 071B3 032 10 2 MS10 without EV R L 3 = 45l/h no meaning071G0... MS11 with EV MS12 with EV 5 = 70l/h MS21 with EV Example ➩ MS11 R 3 071G0126 1 2

3

4

1

2

3

Oil pump

CSB.172

Oi

l p

um

p

PO

(15)

DANFOSS

PUMP

DANFOSS

OLD PUMP REPLACEMENT TABLE

Component Description Manufact. ref

DANF 70-3130 Danfoss pump 70-3130 70-3130 = 303432

DANF 70-3132 70-3132 70-3132 = 303432 DANF 70-3140 70-3140 303432 + 301310 DANF 70-3142 70-3142 303432 + 301310 DANF 70-3200 70-3200 70-3200 = 303031 DANF 70-3202 70-3202 70-3202 = 303031 DANF 70-3210 70-3210 70-3210 = 303033 DANF 70-3212 70-3212 70-3212 = 303033 DANF 70-3230 70-3230 70-3230 = 303031 DANF 70-3232 70-3232 70-3232 = 303031 DANF 70-3240 70-3240 70-3240 = 303033 DANF 70-3242 70-3242 70-3242 = 303033 DANF 70-3300 70-3300 -DANF 70-3302 70-3302 -DANF 70-3310 70-3310 70-3310 = 303043 DANF 70-3312 70-3312 70-3312 = 303043 DANF 70-3350 70-3350 -DANF 70-3352 70-3352 -DANF 70-3360 70-3360 70-3360 = 303043 DANF 70-3362 70-3362 70-3362 = 303043 DANF 70-3410 70-3410 70-3410 = 303093 DANF 70-3412 70-3412 70-3412 = 303093 DANF 70-4030 70-4030 70-4030 = 303430 DANF 70-4032 70-4032 70-4032 = 303430 DANF 70-4040 70-4040 303430 + 301310 DANF 70-4042 70-4042 303430 + 301310 DANF 70-4120 70-4120 70-4120 = 303430 DANF 70-4121 70-4121 70-4121 = 303430 DANF 70-4130 70-4130 70-4130 = 303432 DANF 70-4132 70-4132 70-4132 = 303432 DANF 70-4140 70-4140 303432 + 301310 DANF 70-4142 70-4142 303432 + 301310 DANF 70-4330 70-4330 70-4330 = 303430 DANF 70-4332 70-4332 70-4332 = 303430 DANF 70-4340 70-4340 303430 + 301310 DANF 70-4342 70-4342 303430 + 301310 DANF 70-4492 70-4492 70-4492 = 303432 DANF 70-5300 70-5300 70-5300 = 303021 DANF 70-5302 70-5302 70-5302 = 303021 DANF 70-5322 70-5322 70-5322 = 303025 DANF 70-5330 70-5330 70-5330 = 303025 DANF 70-5332 70-5332 70-5332 = 303025 DANF 70-5370 70-5370 70-5370 = 303021 DANF 70-5372 70-5372 70-5372 = 303021 DANF 70-6400 70-6400 70-6400 = 301171 DANF 70-6410 70-6410 70-6410 = 301171 DANF 70-6480 70-6480 70-6480 = 301161 DANF 70-7300 70-7300 70-7300 = 301151 DANF 70-7310 70-7310 70-7310 = 301151 DANF 70L 3002 70L 3002 - DANF 70L 3130 70L 3130 70L 3130 = 303433 DANF 70L 3132 70L 3132 70L 3132 = 303433 DANF 70L 3140 70L 3140 303433 + 301310 DANF 70L 3142 70L 3142 303433 + 301310 DANF 70L 3200 70L 3200 -DANF 70L 3202 70L 3202 -DANF 70L 3210 70L 3210 70L 3210 = 303034 DANF 70L 3212 70L 3212 70L 3212 = 303034 DANF 70L 3230 70L 3230 -DANF 70L 3232 70L 3232 -DANF 70L 3240 70L 3240 70L 3240 = 303034 DANF 70L 3242 70L 3242 70L 3242 = 303034 DANF 70L 3300 70L 3300 70L 3300 = 303042 DANF 70L 3302 70L 3302 70L 3302 = 303042 DANF 70L 3310 70L 3310 70L 3310 = 303044 DANF 70L 3312 70L 3312 70L 3312 = 303044 DANF 70L 3350 70L 3350 70L 3350 = 303042 DANF 70L 3352 70L 3352 70L 3352 = 303042 DANF 70L 3360 70L 3360 70L 3360 = 303044 DANF 70L 3362 70L 3362 70L 3362 = 303044 DANF 70L 3400 70L 3400 70L 3400 = 303092 DANF 70L 3402 70L 3402 70L 3402 = 303092 DANF 70L 3410 70L 3410 70L 3410 = 303094 DANF 70L 3412 70L 3412 70L 3412 = 303094 DANF 70L 3480 70L 3480 70L 3480 = 303054 DANF 70L 3482 70L 3482 70L 3482 = 303054 DANF 70L 4030 70L 4030 70L 4030 = 303431 DANF 70L 4032 70L 4032 70L 4032 = 303431 DANF 70L 4040 70L 4040 303431 + 301310 DANF 70L 4042 70L 4042 303431 + 301310 DANF 70L 4130 70L 4130 70L 4130 = 303433 DANF 70L 4132 70L 4132 70L 4132 = 303433

Component Description Manufact. ref

DANF 70L 4140 Danfoss pump 70L 4140 303433 + 301310

DANF 70L 4142 70L 4142 303433 + 301310 DANF 70L 4330 70L 4330 70L 4330 = 303431 DANF 70L 4332 70L 4332 70L 4332 = 303431 DANF 70L 4340 70L 4340 303433 + 301310 DANF 70L 4342 70L 4342 303431 + 301310 DANF 70L 5300 70L 5300 70L 5300 = 303022 DANF 70L 5302 70L 5302 70L 5302 = 303022 DANF 70L 5310 70L 5310 70L 5310 = 303024 DANF 70L 5312 70L 5312 70L 5312 = 303024 DANF 70L 5322 70L 5322 70L 5322 = 303026 DANF 70L 5330 70L 5330 70L 5330 = 303026 DANF 70L 5332 70L 5332 70L 5332 = 303026 DANF 70L 5370 70L 5370 70L 5370 = 303022 DANF 70L 5372 70L 5372 70L 5372 = 303022 DANF 70L 5380 70L 5380 70L 5380 = 303024 DANF 70L 5382 70L 5382 70L 5382 = 303024 DANF 70L 5392 70L 5392 70L 5392 = 303026 DANF 70L 6400 70L 6400 70L 6400 = 301173 DANF 70L 6410 70L 6410 70L 6410 = 301173 DANF 70L 6480 70L 6480 70L 6480 = 301163 DANF 70L 7300 70L 7300 70L 7300 = 301153 DANF 70L 7310 70L 7310 70L 7310 = 301153 DANF 71B 0030 71B 0030 -DANF 71B 0101 71B 0101 71B 0101 = 303400 DANF 71B 0102 71B 0102 71B 0102 = 303400 DANF 71B 0103 71B 0103 303400 + 303357 DANF 71B 0104 71B 0104 303400 + 303357 DANF 71B 0105 71B 0105 303400 + 303357 DANF 71B 0106 71B 0106 303400 + 303357 DANF 71B 0107 71B 0107 71B 0107 = 303400 DANF 71B 0108 71B 0108 71B 0108 = 303400 DANF 71B 0112 71B 0112 71B 0112 = 303400 DANF 71B 0113 71B 0113 71B 0113 = 303400 DANF 71B 0132 71B 0132 303400 + 303359 DANF 71B 0201 71B 0201 71B 0201 = 303402 DANF 71B 0202 71B 0202 71B 0202 = 303402 DANF 71B 0203 71B 0203 303402 + 303357 DANF 71B 0204 71B 0204 303402 + 303357 DANF 71B 0205 71B 0205 303402 + 303357 DANF 71B 0206 71B 0206 303402 + 303357 DANF 71B 0207 71B 0207 71B 0207 = 303402 DANF 71B 0208 71B 0208 71B 0208 = 303402 DANF 71B 1101 71B 1101 71B 1101 = 303401 DANF 71B 1102 71B 1102 71B 1102 = 303401 DANF 71B 1103 71B 1103 303401 + 303357 DANF 71B 1104 71B 1104 303401 + 303357 DANF 71B 1105 71B 1105 303401 + 303357 DANF 71B 1106 71B 1106 303401 + 303357 DANF 71B 1107 71B 1107 303401 + 303357 DANF 71B 1108 71B 1108 71B 1108 = 303401 DANF 71B 1111 71B 1111 71B 1111 = 303401 DANF 71B 1112 71B 1112 71B 1112 = 303401 DANF 71B 1114 71B 1114 303401 + 303357 DANF 71B 1116 71B 1116 303401 + 303357 DANF 71B 1120 71B 1120 71B 1120 = 303401 DANF 71B 1122 71B 1122 71B 1122 = 303401 DANF 71B 1126 71B 1126 303401 + 303357 DANF 71B 1128 71B 1128 71B 1128 = 303401 DANF 71B 1132 71B 1132 303401 + 303359 DANF 71B 1134 71B 1134 71B 1134 = 303401 DANF 71B 1136 71B 1136 71B 1136 = 303401 DANF 71B 1138 71B 1138 71B 1138 = 303401 DANF 71B 1201 71B 1201 71B 1201 = 303403 DANF 71B 1202 71B 1202 71B 1202 = 303403 DANF 71B 1203 71B 1203 303403 + 303357 DANF 71B 1204 71B 1204 303403 + 303357 DANF 71B 1206 71B 1206 303403 + 303357 DANF 71B 1207 71B 1207 71B 1207 = 303403 DANF 71B 1208 71B 1208 71B 1208 = 303403 DANF 71B 2101 71B 2101 71B 2101 = 303430 DANF 71B 2102 71B 2102 71B 2102 = 303430 DANF 71B 2104 71B 2104 71B 2104 = 303430 DANF 71B 2201 71B 2201 71B 2201 = 303432 DANF 71B 2202 71B 2202 71B 2202 = 303432 DANF 71B 2203 71B 2203 71B 2203 = 303432 DANF 71B 3101 71B 3101 71B 3101 = 303431 DANF 71B 3102 71B 3102 71B 3102 = 303431 DANF 71B 3103 71B 3103 71B 3103 = 303431 DANF 71B 3201 71B 3201 71B 3201 = 303433 DANF 71B 3202 71B 3202 71B 3202 = 303433 DANF 71B 4101 71B 4101 71B 4101 = 303430

Oil pump

Oi

l p

um

p

PO

References

Related documents

This study provides data on four mental health outcomes from a random sample of women at distinct life stages in rural India demonstrating that scores for well-being and symptoms

It describes specific significant deficits in cognitive and motor impulsivity and strategic planning in the opioid dependent population (HEROIN and/or METHADONE

An attempt can then be made to stop the estrogen treatment and to induce a cyclical bleeding by the administration of 1 tablet Primolut N twice daily from the 19th

Factors like financial incentives and non financial inventive, performance appraisal system, good relationship with co-workers, promotional opportunities in the present job,

1996 Sleep onset latency and sleep-wake alternating pattern during sleep onset period:Effects of sleep deprivation evaluated by a finger tapping task FTT.. 10th Annual Meeting of

Distribution (Regulated) (63 DisCos) Transmission (Regulated) (110.000 km > 138kV) Generation (Competitive) (128 GW) • Movements to implement new auction rules. (regional,

Data collected as part of this IRWMP can be used to support existing state programs such as the Surface Water Ambient Monitoring Program, the Groundwater Ambient Monitoring and

Dessa forma, o construto country equity proposto por Pappu e Quester (2010) com cinco dimensões, compreendendo conhecimento do país, imagem micro de país, imagem