Nokia WCDMA Base Station BTS Alarm Descriptions BTS SW WN3.0 dn7095963 Issue 1-0 en # Nokia Corporation 1 (148)

(2)

The information in this document is subject to change without notice and describ es only the product defined in the introduction of this documentation. This docu ment is intended for the use of Nokia's customers only for the purposes of the a greement under which the document is submitted, and no part of it may be reprodu ced or transmitted in any form or means without the prior written permission of Nokia. The document has been prepared to be used by professional and properly tr ained personnel, and the customer assumes full responsibility when using it. Nok ia welcomes customer comments as part of the process of continuous development a nd improvement of the documentation. The information or statements given in this document concerning the suitability, capacity, or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Nokia and the customer. However, Nokia has made al l reasonable efforts to ensure that the instructions contained in the document a re adequate and free of material errors and omissions. Nokia will, if necessary, explain issues which may not be covered by the document. Nokia's liability for any errors in the document is limited to the documentary correction of errors. N OKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARY LOSSES), that might ar ise from the use of this document or the information in it. This document and th e product it describes are considered protected by copyright according to the ap plicable laws. NOKIA logo is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be trademarks of their respective c ompanies, and they are mentioned for identification purposes only. Copyright © Noki a Corporation 2006. All rights reserved.

2 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(3)

Contents

Contents 3 1 2 2.1 2.2 2.3 2.4 3 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.19 4.20 4.21 4.22 4.23 4.24 4.25 4.26 4.27 4.28 4.29 4.30 4.31 4.32 4.33 4.34 4.35 About this document 7 Alarm handling 9 General 9 Instructions for solving problems Blocking and locking 10 Identifying faulty units 10

9

Nokia UltraSite and MetroSite WCDMA BTS alarm table 25 Alarms 27 Active clock tu ning fault 27 Antenna# connection fault 28 ATM, A2EA configuration error 29 ATM cell loss 29 ATM faulty 30 ATM processor faulty 31 ATM traffic overload 32 Base station ambient temperature below minimum limit 32 Base station ambient temperat ure exceeds maximum limit 33 BS SW download or activation failed 34 BTS Blocked 35 BTS config error (all units in a cell must be of same freq) 36 BTS config err or (different WTR variants cannot coexist in cell) 36 BTS config error (incorrec t carrier candidates) 37 BTS config error (Not enough HW for LCR) 38 BTS config error (SRC DL must use same WTR TRXs) 39 BTS config error (WAF overload, 50W not in dual WPA config) 39 BTS config error (WPA / WSMA version conflict in cell) 4 0 BTS config error (WSMA and WSMB cannot coexist) 41 BTS config error (WTR used as dual TRX behind WSMA) 41 BTS file error 42 BTS RNC interface signalling link failure 43 BTS time not corrected 44 Cabinet door open 45 Cell blocked 46 Cell b lock rejected by RNC 46 Cell calibration failure 47 Cell power monitoring 48 Cel l power parameter out of range 49 Commissioning parameter mismatch 49 Communicat ion failure inside WSP 50 Communication failure with RNC 51 Default antenna dela y value is used for LCS-RTT 52 Difference between BTS master clock and reference frequency 53 Diversity branch masthead amplifier fault 56

dn7095963 Issue 1-0 en # Nokia Corporation

(4)

4.36 4.37 4.38 4.39 4.40 4.41 4.42 4.43 4.44 4.45 4.46 4.47 4.48 4.49 4.50 4.51 4.52 4.53 4.54 4.55 4.56 4.57 4.58 4.59 4.60 4.61 4.62 4.63 4.64 4.65 4.66 4.67 4.68 4.69 4.70 4.71 4.72 4.73 4.74 4.75 4.76 4.77 4.78 4.79 4.80 4.81 4.82 4.83 4.84 4.85 4.86

DSC-bus failure 57 DSP failure in radiolink creation 58 Error in commissioning d ata 59 Error in file server during SW download 60 Failure in AXU initialization 60 Fan module operation degraded 61 Fatal alarm 62 Fault between WAM and WSP SFN (WSP) 63 Fault in ATM interface 64 Fault in ATM interface 65 Fault in OM and DS P SW interface 66 File corrupted in SW download 66 Flash operation failure 67 Ga in adjust alarm 68 Incompatible SW version detected 69 Incompatible unit detecte d 70 Initial calibration not started because other cell not cleared 71 Invalid c arrier in WTR 71 Invalid frequency channel for the BTS HW 72 LPA faulty 73 LPA g ain fault 74 LPA input signal level is too high 74 LPA linearization fault 75 LP A power supply alarm 76 LPA reflected power too high 76 LPA temperature is dange rously high 77 Main branch masthead amplifier fault 78 Mains power break, runnin g battery backup 79 Major alarm 79 Minor alarm 80 Missing NBAP cell parameters, defaults are used 81 No connection to AXU 82 No connection to unit 82 No connect ion to WEA and unable to detect External alarms 84 Non-fatal ATM traffic overloa d 85 Not enough WAF resources in LCR 86 Not enough WSP resources per cell 86 No WSM resources 87 Oven oscillator clock missing 88 Oven oscillator heating failur e 89 POST test failed 89 Power unit input voltage fault 90 Power unit output vol tage fault 91 R-bus error 92 ROM disk corrupted during SW update 93 SFN synchron ization failure 93 SFN synchronization failure 94 SFN synchronization failure 95 Smoke alarm 96 SW does not support commissioning file 96 System frame clock mis sing 97

4 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(5)

4.87 4.88 4.89 4.90 4.91 4.92 4.93 4.94 4.95 4.96 4.97 4.98 4.99 4.100 4.101 4.1 02 4.103 4.104 4.105 4.106 4.107 4.108 4.109 4.110 4.111 4.112 4.113 4.114 4.115 4.116 4.117 4.118 4.119 4.120 4.121 4.122 4.123 4.124 4.125 4.126 4.127 4.128 4 .129 4.130 4.131 4.132 4.133 4.134 4.135 4.136 4.137

System frame clock signal missing 98 T-bus error 98 Telecom cell enabling or dis abling failed 99 Telecom configuration failure 100 Timeout, commissioned resourc e not ready 101 Too many carriers allocated for LPA 102 Traffic flow in a non-ex istent ATM connection 102 Transmission clock missing 103 Unit autonomous reset a s a recovery action 104 Unit blocked 105 Unit has lost connection to temperature sensor 106 Unit initialization failure 107 Unit initialization failure 107 Unit not supported by current BTS SW version 108 Unit SW download failed 109 Unit sy nchronization failed 111 Unit temperature is high 111 Unknown cabinet type 112 U nknown HW resource 113 [User defined] 114 WAF low noise amplifier faulty 114 WAM SFN polling timeout 115 WCI baseband reference clock failure 116 WEA power regu lator fault 117 WIB unit AC line break fault 118 WIB unit battery failure 119 WI B unit battery temperature out of range 119 WIB unit power back-up time alarm 12 0 WMC oven oscillator fault 121 WPA power level changed 122 WSC oven oscillator fault 122 WSC phase difference jammed to zero reading 126 WSC switch unsuccessfu l 127 WSC/WMC transmission clock missing 128 WSMA RR-bus error 129 WSMA SR-bus e rror 130 WSMA ST-bus error 131 WSMA T-bus error 132 WSMB does not receive frame clock 133 WSMB RR-bus error 133 WSMB SR-bus error 134 WSMB ST-bus error 135 WSMB T-bus error 136 WSMB unit reset 137 WSP PCI-bus failure 138 WSP unit internal f ailure 139 WTR internal clock faulty 139 WTR internal clock faulty 140 WTR local oscillator not locked 141 WTR loop synthesizer not locked 141 WTR or WPA output power measurement fault 142

dn7095963 Issue 1-0 en # Nokia Corporation 5 (148)

(6)

4.138 4.139 4.140 4.141 4.142 4.143 WTR WTR WTR WTR WTR WTR

output power decreased 143 output power fault 144 power supply voltage fault 145 RT-bus fault 145 synthesizer is not locked 146 temperature is high 147

6 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(7)

1

About this document

The purpose of this document is to describe the alarms and alarm handling of the Nokia UltraSite WCDMA Base Station (BTS) family, the Nokia MetroSite WCDMA Base Station and the Nokia MetroSite 50 WCDMA Base Station. BTS software (SW) uses t hese alarms as a basis for internal diagnosis and fault reporting through the Ra dio Network Controller (RNC) to the Operations Support System (OSS) and BTS Site Manager.

dn7095963 Issue 1-0 en # Nokia Corporation 7 (148)

(8)

8 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(9)

2 2.1

Alarm handling General

Base Station (BTS) alarm handling is based on unit state information. It prevent s the sending of unnecessary alarms by checking and updating unit states. Fault messages come either from hardware devices or software components. The faults ar e system or hardware specific. The Fault Diagnosis System creates upper network alarms, which are based on an analysis of the faults, and sends them to the BTS Site Manager and RNC. In addition to routing to the RNC, the alarms are buffered and, for example, active BTS alarms can be seen from the RNC. NetAct is used fo r handling the BTS alarms. The BTS is able to maintain alarm handling after it h as been commissioned and is in a configured state. During the start-up, the BTS waits for the real time clock from the Network Time Protocol (NTP) server, and t he fault diagnosis starts after the time has been set or a time-out has been det ected. If the BTS is unable to set the time using the NTP server, the default ti me (1.1.1990) will be used.

2.2

Instructions for solving problems

When starting to solve a problem, first refer to the instructions given in the i ndividual alarm descriptions. Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units at the BTS. Make su re the environment does not cause the fault. For more information on implementat ion, normal daily operations, maintenance, and troubleshooting, refer to Nokia U ltraSite WCDMA Base Station (BTS) family, Nokia MetroSite WCDMA Base Station and Nokia MetroSite 50 WCDMA Base Station Product Documentation sets.

(10)

If an active alarm is a 'Start' alarm, a unit block/unblock (if supported by the unit) or site reset is required to cancel it. If the site reset or unit block/u nblock does not help, replace the faulty unit. See the fields 'Source of the ala rm' and 'Instructions' in the corresponding alarm description. If you cannot sol ve the problem by yourself, contact the local Help Desk.

2.3

Blocking and locking

The 'Cancel' alarms are always sent to hosts (BTS Site Manager and RNC). When th e unit or cell is in a blocked state, the 'Start' alarms are only sent to the BT S Site Manager. When a unit or cell is unblocked, all the active alarms related to the unblocked unit or cell are automatically sent to the hosts. The locked or unlocked state of a cell has no effect on sending alarms to the hosts.

2.4

Identifying faulty units

This section describes how the plug-in units are identified in different WCDMA B TS cabinets and how a faulty unit can be located with the NetAct system. See bel ow the explanations of an example 'Alarm Dialog' window for different fields in Figure NetAct Alarms window.

.

7652 *: reported severity Suppl info field: fault name Diag info field: (01) (02 ) (0A) (0010) (WFAA 04) number of the rack where the plug-in unit is located (HE X) number of the shelf where the plug-in unit is located (HEX) number of the slo t where the plug-in unit is located (HEX) not applicable faulty unit and ID .

(11)

Unit location numbers are used in alarm information to locate a failed unit. The main principle for numbering locations is from top to bottom and from the left to the right. Location numbers are defined with the following parameters: RACK S HELF SLOT Specifies the rack of the cabinet and separates BB and RF compartments from each other Specifies the shelf in the cabinet Specifies the location on th e shelf

The figures below indicate how the rack, shelf and slot are defined in different WCDMA BTS cabinets.

dn7095963 Issue 1-0 en # Nokia Corporation 11 (148)

(12)

Figure 1.

Supreme cabinet 12 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(13)

Figure 2. Optima cabinet

dn7095963 Issue 1-0 en # Nokia Corporation 13 (148)

(14)

Figure 3.

Optima Compact Outdoor (WREB) cabinet 14 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(15)

Figure 4.

Optima Compact IBBU cabinet dn7095963 Issue 1-0 en # Nokia Corporation 15 (148)

(16)

Figure 5.

Optima Compact RF extension cabinet 16 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(17)

Figure 6.

Triple-mode cabinet dn7095963 Issue 1-0 en # Nokia Corporation 17 (148)

(18)

Figure 7.

MetroSite cabinet 18 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(19)

Figure 8.

MetroSite 50 cabinet

The figures below indicate how the fans are defined in different WCDMA BTS cabin ets. Note fan control naming: 'FAN UNIT' refers to a group of fans including the fan control unit. A 'fan' is a single blower.

dn7095963 Issue 1-0 en # Nokia Corporation 19 (148)

(20)

Figure 9.

Fan mapping in Supreme cabinet

HEX FAN 59 WPA WEAC 53 54 55 56 57 58 WTR WFD 155 MFUA 153 154 MFUA MFUA Figure 10.

Fan mapping in Optima Compact Outdoor (WREB) cabinet 20 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(21)

Figure 11.

Fan mapping in Optima Compact IBBU cabinet Figure 12.

Fan mapping in Optima Compact RF extension cabinet dn7095963 Issue 1-0 en

# Nokia Corporation 21 (148)

(22)

Figure 13.

Fan mapping in Triple-mode cabinet 22 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(23)

Figure 14.

Fan mapping in MetroSite cabinet dn7095963 Issue 1-0 en

# Nokia Corporation 23 (148)

(24)

Figure 15.

Fan mapping in MetroSite 50 cabinet 24 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(25)

3

Name: Product: Detecting unit: Fault source:

Nokia UltraSite and MetroSite WCDMA BTS alarm table The table below describes the fields in the alarm table: Table 1.

Description of the fields in the alarm table

The name of the fault. The name of the product in question. The unit that detect s the fault. The equipment suspected to be faulty (sub-unit in parentheses). Not e that sometimes the actual source of the alarm is different than the one that d etects the fault.

Meaning: Event type:

A description of the fault situation. The options are: Event (Transient or Distu r)

. . . . .

Event type alarms can be seen in the RNC in 'Alarm History' Notification type al arm 'Event' alarm is not cancelled, because it is never active No recovery actio ns Event type alarm is shown in the BTS Site Manager as 'Transient' and in RNC a s 'Distur' Alarm, a fault situation The alarm is not automatically cleared (with out manual operation and maintenance work), even though the problem has been sol ved, but requires at least blocking/ unblocking the unit or site reset. Recovery actions depend on the reported severity Faults can be in a start or cancel stat e The alarm is automatically cleared when the problem has been solved

Start . . .

Start/Cancel . .

(26)

Table 1. Unit status:

Description of the fields in the alarm table (cont.) The options are:

Out of order Degraded Working Info Effect:

The unit does not work The main functions of the unit work, but not all All func tions are working, but some trouble has been notified Status change information A description of how this fault affects the operations of this unit, and how it affects the operations of other units. The following questions are considered: Does the status of the unit or its sub-units have any effect on the interpretati on of the fault? Does the fault have an effect on other active faults? Reported alarms: 7650 BASE STATION FAULTY

. . .

Start, disables all cells Cancel, causes a site reset No new 7651, 7653 or 7654 alarms are reported when 7650 is active There is no limit to how many 7651 alarm s can be active at the same time There is no limit to how many 7652 alarms can b e active at the same time Start, the affected cell state is set disabled Cancel, the affected cell state is set enabled There is no limit to how many 7654 alarm s can be active at the same time There is no limit to how many 7655 alarms can b e active at the same time

7651 BASE STATION OPERATION DEGRADED .

7652 BASE STATION NOTIFICATION .

7653 CELL FAULTY . .

7654 CELL OPERATION DEGRADED .

7655 CELL NOTIFICATION .

LED display:

The colour of the LED representing the fault level of the unit. The options are: Stable red Blinking red Stable yellow Blinking yellow Stable green

Major alarm Minor alarm Unit in standby state or unit blocking Unit in self-heat ing state or software downloading Unit on and working

(27)
(28)

4 4.1 Alarms

Active clock tuning fault

Name Product Detecting unit Fault source Meaning Active clock tuning fault Supre me; Optima; MetroSite; Triplemode WAM Active WSC, WMC Phase measurement cannot b e per formed in the active WSC or WMC. Start / Cancel Degraded If there is only one WSC or both the ac tive and redundant WSCs are faulty, the synchronisation d oes not work and the BTS is not operational. If there is a re dundant WSC and th e recovery switch operation was successful, the BTS can work normally. If the un it is WMC and it is faulty, the synchronisation does not work and the BTS is not operational. 7651 BASE STATION OPERATION DEGRADED (if no working WSC or WMC) 76 52 BASE STATION NOTIFICATION (if working redundant WSC available) LED display In structions Stable red 1. Block/unblock the faulty unit. 2. Replace the faulty un its.

Event type Unit status Effect Reported alarms

dn7095963 Issue 1-0 en # Nokia Corporation 27 (148)

(29)

Note that because of a fault situation in the active clock, the redundant clock is not tuned. To make sure that the tuning is correct, run "Fast Tune BTS Clock" with the BTS Site Manager after switchover when the new WSC is taken into use. If there is a WMC or only one WSC, the tuning will continue but cells will remai n disabled.

4.2

Antenna# connection fault

Name Product Antenna# connection fault Supreme; Optima; Optima IBBU; Optima Comp act RF Extension; MetroSite; Triplemode; MetroSite 50 WAF WAF The Bias-T has det ected that the re flected TX power from the antenna has increased. The antenna c able between the WAF and MHA is faulty or the anten na is faulty. The BIAS-T may be faulty. Start Out of order The cell is out of use. 7653 CELL FAULTY (all TX/ RX-BTUs in the cell are faulty) 7654 CELL OPERATION DEGRADED (there is a working /degraded BTU in the cell) LED display Instructions N/A 1. Check the cabling in the commissioning file. 2. Check the antenna line. 3. Check the PITA Cable conn ection (RJ45).

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms 28 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(30)

4. Check the Bias-T. 4.3

ATM, A2EA configuration error

Name Product ATM, A2EA configuration error Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WAM The RNC A2EA t ransport layer address does not comply with the given BTS A2EA address. Start Wo rking If AAL2 multiplexing is not in use, BTS operation is not affected. If the error is in the AXC (if AAL2 multiplexing is in use), the BTS may reject AAL2 co nnection es tablishment requests. 7652 BASE STATION NOTIFICATION Stable green Ch eck and re-commission the AXC (if AAL2 multiplexing is in use), RNC or BTS with the correct BTS A2EA ad dresses.

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms LED display Instructions 4.4

ATM cell loss

Name Product ATM cell loss Supreme; Optima; Optima IBBU; Otima Compact RF Extens ion; MetroSite; Triplemode; MetroSite 50

dn7095963 Issue 1-0 en # Nokia Corporation 29 (148)

(31)

Detecting unit Fault source Meaning

WAM WAM ATM cells are lost. The cell loss can be caused by a traffic overload, b y the WAM receiving an invalid ATM cell or AAL5 packet, or by the data corruptio n on Iub. Start / Cancel Working This can result in data loss and resend ing of data. 7652 BASE STATION NOTIFICATION Blinking red 1. Check the WAM, AXU and the cabling between them. 2. Check the other active alarms. 3. Check the ATM configu ration. 4. Check the data integrity from the incoming Iub.

Event type Unit status Effect

Reported alarms LED display Instructions 4.5

ATM faulty

Name Product ATM faulty Supreme; Optima; Optima IBBU; Optima Compact RF Extensio n; MetroSite; Triplemode; MetroSite 50 WAM WAM A WAM internal failure. Start Out of order

Detecting unit Fault source Meaning Event type Unit status Effect 30 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(32)

The BTS capacity decreases. If the faulty unit is the master WAM, the BTS is fau lty. Reported alarms 7650 BASE STATION FAULTY (master WAM) 7651 BASE STATION OPE RATION DEGRADED (slave WAM) LED display Instructions Stable red 1. Check the AXC settings. 2. Reset the BTS. 3. If the BTS reset does not help, change the alarm ing unit.

4.6

ATM processor faulty

Name Product ATM processor faulty Supreme; Optima; Optima IBBU; Optima Compact R F Extension; MetroSite; Triplemode; MetroSite 50 WAM WAM, WSPC, WSPD, WSPE There is a fault in the WAM processor SFN interrupt or the SFN is not being up dated in the WSPC/WSPD/WSPE MCU. There is a fault in the WAM internal bus or between t he WAM and WSP. There is a MCU failure in the WAM or the ATM loop test at startu p has failed. Event type Unit status Effect Reported alarms Start Out of order T he BTS capacity is decreased. 7651 BASE STATION OPERATION DEGRADED Stable red Detecting unit Fault source Meaning

LED display

dn7095963 Issue 1-0 en # Nokia Corporation 31 (148)

(33)

Instructions

1. Check the AXC settings (WAM loopback VC, for example). 2. Reset the BTS. 3. I f the BTS reset does not help, change the alarming unit.

4.7

ATM traffic overload

Name Product ATM traffic overload Supreme; Optima; Optima IBBU; Optima Compact R F Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM Ultra Site, MetroSite, MetroSite 50, Triple-mode: WAM, WSP C A buffer overflow caused by traffic over load. The maximum capacity is ex ceed ed and some data discarded. Start / Cancel Degraded This alarm has variable cons equences. Calls may be cut off and, in worst cases, cells may be disabled. 7651 BASE STATION OPERATION DEGRADED Blinking red 1. Check and correct the ATM config uration. 2. Check the other active transmissionrelated alarms.

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

LED display Instructions 4.8

(34)

Name

Base station ambient temperature below minimum limit Supreme; Optima; Optima IBB U; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM Transmis sion WFA, BB_WFA, WFD The sensor measuring temperature out side the cabinet, has reported that the ambient temperature is below the mini mum allowed value. Star t / Cancel Working Possibly results in other faults. 7652 BASE STATION NOTIFICAT ION Check the environment conditions of the site.

Product

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms LED display Instructions 4.9

Base station ambient temperature exceeds maximum limit

Name Base station ambient temperature ex ceeds maximum limit Supreme; Optima; Op tima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM Transmission WFA, BB_WFA, WFD

Product

Detecting unit Fault source Meaning dn7095963 Issue 1-0 en

# Nokia Corporation 33 (148)

(35)

The sensor measuring the temperature outside the cabinet, has reported that the ambient temperature is above the maximum allowed value. Event type Unit status E ffect Reported alarms LED display Instructions Start / Cancel Working Possibly r esults in other faults. 7652 BASE STATION NOTIFICATION Check the environment con ditions of the site.

4.10

BS SW download or activation failed

Name Product BS SW download or activation failed Supreme; Optima; Optima IBBU; O ptima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, Tripl e-mode, MetroSite, MetroSite 50: WAM UltraSite, Triple-mode, MetroSite, MetroSit e 50: WAM, WTR, WPA/WMP The SW update to the BTS has failed. The error can be ca used by a unit reset during the SW update, a hardware pro blem in the unit or ca binet, or a cor rupted flash file system. Start / Cancel Degraded The SW update to this BTS may not be possible without special actions. The BTS continues its o peration with the old software. 7651 BASE STATION OPERATION DEGRADED

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

34 (148)

(36)

LED display Instructions

Blinking red 1. If the 'ROM disk corrupted during SW update' or other flash memo ry-related alarm is active for the faulty unit at the same time, replace the fau lty unit. 2. Retry the SW update. 3. Replace the failing unit.

4.11

BTS Blocked

Name Product BTS Blocked Supreme; Optima;Optima IBBU; Optima Compact RF Extensio n; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, Tripl e-mode: WAM UltraSite, MetroSite, MetroSite 50, Triple-mode: Master WAM The BTS is blocked with the BTS Site Manager. The meaning of the fault is to avoid alarm s that may rise during a BTS maintenance task. Start Working The BTS does not se nd alarms to the RNC when the BTS is blocked. Alarm cancels are sent to the RNC. All cells are disabled. Reported alarms LED display Instructions 7650 BASE STAT ION FAULTY Stable green To cancel the alarm, unblock the BTS. Unblocking the BTS causes a site reset.

Detecting unit Fault source Meaning

Event type Unit status Effect dn7095963 Issue 1-0 en

# Nokia Corporation 35 (148)

(37)

4.12

BTS config error (all units in a cell must be of same freq)

Name BTS config error (all units in a cell must be of same freq) Supreme; Optima ; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode WAM CELL A uni t with an incompatible frequency type has been detected. All units in the cell m ust be of the same frequency type. Start / Cancel Out of order The capacity drop s. Cell(s) may remain down. 7653 CELL FAULTY

Product

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms

LED display Instructions

Stable red Check the unit frequency types in the cell and replace the incompatib le unit with a compatible one.

4.13

BTS config error (different WTR variants cannot coexist in cell)

Name BTS config error (different WTR variants cannot coexist in cell) Supreme; O ptima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode WAM

Product

(38)

Fault source Meaning

RX - WTR There are different WTR variants in the same cell. Start / Cancel Degra ded The conflicting WTR unit is marked as faulty (not used by the Telecom), and the cell coverage may therefore de crease. For example, if the conflicting WTRA is configured as the transmitter for the cell, the cell may also be shut down. 7 654 CELL OPERATION DEGRADED Blinking red Replace the conflicting WTR unit with a compatible unit.

Event type Unit status Effect

Reported alarms LED display Instructions 4.14

BTS config error (incorrect carrier candidates)

Name BTS config error (incorrect carrier candi dates) Supreme; Optima; Optima IB BU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM UltraSite, MetroSite, MetroSite 50, Tr iple-mode: LCR Carrier candidates are commissioned for each cell (not WTR/LTX sp ecific). Start Degraded UltraSite, MetroSite, MetroSite 50, Triple-mode:

Product

Detecting unit Fault source Meaning

(39)

The BTS cannot configure the TRX to a channel that is not physically supported b y the WTR. The WTR or TRX is inoperational. Reported alarms LED display Instruct ions 7654 CELL OPERATION DEGRADED Blinking red Recommission (Reconfiguration com mis sioning) the BTS with the correct carrier candidate values.

4.15

BTS config error (Not enough HW for LCR)

Name BTS config error (Not enough HW for LCR) Supreme; Optima; Optima IBBU; Opti ma Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM LCR A dual carr ier WTR has been replaced with a single carrier WTR, and it cannot serve both ce lls commissioned to the WTR. Start/Cancel Out of order The BTS capacity drops. 7 653 CELL FAULTY Stable red Replace the single carrier WTR with a dual carrier WT R.

Product

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms LED display Instructions 38 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(40)

4.16

BTS config error (SRC DL must use same WTR TRXs)

Name BTS config error (SRC DL must use same WTR TRXs) Supreme; Optima; Optima IB BU; Optima Compact RF Extension; Triplemode WAM WTRB, WTRD, WTRF, WTRG Main and diversity transmission branches are located on different WTR units (they must be in the same WTR with the Smart Radio Concept downlink (SRC DL) configuration). Start Out of order The cell capacity decreases. 7654 CELL OPERATION DEGRADED Rec ommission the BTS with the correct TRX parameters.

Product

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms LED display Instructions 4.17

BTS config error (WAF overload, 50W not in dual WPA config)

Name BTS config error (WAF overload, 50W not in dual WPA config) Supreme; Optima ; Optima IBBU; Optima Compact RF Extension WAM WPA

Product

Detecting unit Fault source Meaning dn7095963 Issue 1-0 en

# Nokia Corporation 39 (148)

(41)

Two 50 W WPAs are coupled to one WAF, or one 50 W WPA and one 28 W WPA are coupl ed to one WAF. Only two 28 W WPAs can be coupled together to one WAF unit. Event type Unit status Effect Start / Cancel Out of order The TX power is not turned on in the TX chain. The BTS capacity drops. Cell(s) may remain down. 7653 CELL F AULTY

Reported alarms

LED display Instructions

Stable red Replace the 50 W WPAs with the 28 W WPAs. 4.18

BTS config error (WPA / WSMA version conflict in cell)

Name BTS config error (WPA / WSMA version conflict in cell) Supreme; Optima; Opt ima IBBU; Optima Compact RF Extension; MetroSite; Triplemode WAM WPA A WPAI/WPAJ with two carriers and a WOC were detected in the combination with a WSMA. Start / Cancel Out of order The related cell is disabled. 7653 CELL FAULTY

Product

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms 40 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(42)

LED display Instructions

Stable red Replace the WSMA with a WSMB. Or replace the WPAI and WPAJ with a WPA A/WPAB.

4.19

BTS config error (WSMA and WSMB cannot coexist)

Name BTS config error (WSMA and WSMB cannot coexist) Supreme; Optima; Optima IBB U; Optima Compact RF Extension WAM WSMA WSMA and WSMB units are detected in the same cabinet. They cannot coexist in the BTS. Start / Cancel Out of order The BT S is out of order. 7650 BASE STATION FAULTY Stable red Replace the conflicting u nit WSMA with the WSMB, or vice versa.

Product

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms LED display Instructions 4.20

BTS config error (WTR used as dual TRX behind WSMA) Name BTS config error (WTR used as dual TRX behind WSMA) dn7095963 Issue 1-0 en

# Nokia Corporation 41 (148)

(43)

Product

Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode WAM WTRB, WTRD A WTR/WSM conflict is detected. The in compatible WTR cannot ope rate with the WSMA when two TRXs are used. Start Out of order The cell capacity drops or the cell is dis abled. The WTR capacity in the subrack remains unused. The incompatible WTR unit remains unconfigured.

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms LED display Instructions

7653 CELL FAULTY Stable red Replace the incompatible unit or recom mission the B TS (Reconfiguration Commissioning) with only one TRX on.

4.21

BTS file error

Name Product BTS file error Supreme; Optima; Optima IBBU; Optima Compact RF Exte nsion; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, T riple-mode: WAM UltraSite, MetroSite, MetroSite 50 and Triple-mode: WAM

Detecting unit Fault source Meaning 42 (148)

(44)

UltraSite, MetroSite, MetroSite 50, Triple-mode: The BTS unit properties data is invalid or missing. Event type Unit status Effect Reported alarms Start Out of order The BTS does not operate. UltraSite, MetroSite, MetroSite 50, Triple-mode: 7650 BASE STATION FAULTY (master WAM) 7651 BASE STATION OPERATION DEGRADED (sla ve WAM) 7653 CELL FAULTY (WTR or WPA with no redundant unit in a cell) 7654 CELL OPERATION DEGRADED (WTR or WPA with a redundant unit in a cell) LED display Ins tructions Stable red 1. Download the SW again. 2. UltraSite, MetroSite, MetroSit e 50, Triple-mode: If the fault still exists after 10 minutes, replace the alarm ing unit.

4.22

BTS RNC interface signalling link failure

Name Product BTS RNC interface signalling link failure Supreme; Optima; Optima I BBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, Triple-mode, MetroSite, MetroSite 50: WAM UltraSite, Triple-mode, MetroSite, Me troSite 50: WAM, (RNC) Detecting unit Fault source Meaning dn7095963 Issue 1-0 en # Nokia Corporation 43 (148)

(45)

A common or a dedicated Node-B Application Protocol (NBAP) or an AAL2 signalling link failure. It can be caused either by a broken WAM, the RNC, or a transmissi on network problem. Event type Unit status Effect Start / Cancel Degraded The te lecom SW does not operate (on the Telecom Master WAM) and therefore the WAM is n ot operational. The RNC NBAP starts link re-establishment proce dures and keeps on trying until it either succeeds or the link is removed. Signalling and calls through the related cell(s) do not work. The user data cannot be used in the rel ated cell(s), but the WAM can still work as a Telecom Master WAM. Reported alarm s 7651 BASE STATION OPERATION DEGRADED Blinking red UltraSite, MetroSite, MetroS ite 50, Triple-mode: 1. Reset the AXC. 2. Check the transmission links to the RN C. 3. Check the BTS and RNC transmission settings. 4. Check the WAM unit.

LED display Instructions 4.23

BTS time not corrected

Name Product BTS time not corrected Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite: WAM UltraSite: WAM Detecting unit Fault source

44 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(46)

Meaning

The SNTP time can not be fetched from the transport system (MRS/AXC) within the time limit. Start / Cancel Working No real time available. Alarms, logs and all reports include an incorrect time. 7652 BASE STATION NOTIFICATION Stable green C heck the MRS/AXC and RNC transmis sion, and the NTP settings.

Event type Unit status Effect

Reported alarms LED display Instructions 4.24

Cabinet door open

Name Product Cabinet door open Supreme; Optima; Optima IBBU; Optima Compact RF E xtension; MetroSite; MetroSite 50 WEA WEA The cabinet door is open or the cabine t door sensor is faulty. Start / Cancel Working No direct effect on the BTS oper ation. Note that the WHX fan does not stop even when the door is open. 7651 BASE STATION DEGRADED (MetroSite, MetroSite 50) 7652 BASE STATION NOTIFICATION (othe r products) LED display N/A

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms

dn7095963 Issue 1-0 en # Nokia Corporation 45 (148)

(47)

Instructions

1. Ensure that the cabinet door(s) are properly closed. 2. Check that the door s witches function correctly and that they have been adjusted correctly.

4.25

Cell blocked

Name Product Cell blocked Supreme; Optima; Optima IBBU; Optima Compact RF Extens ion; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, Tri ple-mode: WAM UltraSite, MetroSite, MetroSite 50, Triplemode: WTR The user has b locked the cell with the BTS Site Manager. Start / Cancel Working The BTS does n ot send to the RNC any alarms related to the blocked cell or the units commissio ned to the blocked cell. Alarm sending to the BTS Site Manager is always enabled . Alarm cancels are al ways sent to the RNC. Calls through the blocked cell are transferred to another cell. It is not possible to establish new calls through t he blocked cell. Reported alarms LED display Instructions 7653 CELL FAULTY Stabl e green To cancel the alarm, unblock the cell.

Detecting unit Fault source Meaning

Event type Unit status Effect 4.26

Cell block rejected by RNC 46 (148)

(48)

Name Product

Cell block rejected by RNC Supreme; Optima; Optima IBBU; Optima Compact RF Exten sion; MetroSite; Triplemode; MetroSite 50 UltraSite, Triple-mode, MetroSite, Met roSite 50: WAM LCR The cell has been disabled due to BTS internal reasons, for e xample if the RNC has rejected the normal cell blocking dur ing the Intelligent Shutdown. Start / Cancel Working The cell is disabled. 7653 CELL FAULTY Stable g reen 1. Check the other active alarms. 2. Check the mains power supply.

Detecting unit

Fault source Meaning

Event type Unit status Effect Reported alarms LED display Instructions 4.27

Cell calibration failure

Name Product Cell calibration failure Supreme; Optima; Optima IBBU; Optima Compa ct RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WTR TX power calibratio n failure: a CPICH setup failure, a CPICH release failure or a general initial c alibration failure. Start

Detecting unit Fault source Meaning Event type

dn7095963 Issue 1-0 en # Nokia Corporation 47 (148)

(49)

Unit status Effect

Out of order If the initial calibration fails, the cell is faulty. 7653 CELL FAU LTY Stable red 1. Check the unit and RF cabling. 2. Check the alarms for the WPA (s) connected to the faulty WTR. 3. Block/unblock the faulty unit or the WPA con nected to the faulty WTR. The unit needs to be blocked/ unblocked to get it init ialised/ configured again if there was an internal failure or sticking in unit S W. 4. Replace the faulty unit.

Reported alarms LED display Instructions 4.28

Cell power monitoring

Name Product Cell power monitoring Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSit e 50, Triple-mode: WAM UltraSite, MetroSite, MetroSite 50, Triple-mode: WPA The WPA/Radio output power has dropped. There is a fault in the down link transmissi on path. Start Out of order The cell is disabled. 7653 CELL FAULTY

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms LED display

(50)

Instructions

UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the WPA. The u nit needs to be blocked/unblocked to get it initialised/configured again if ther e was an internal failure or sticking in the unit SW. 2. Check the RF TX cabling . 3. Check the WTR. 4. Replace the faulty unit.

4.29

Cell power parameter out of range

Name Product Cell power parameter out of range Supreme; Optima; Optima IBBU; Opt ima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSi te, MetroSite 50, Triple-mode: WAM LCR The power values in the cell configura ti on data sent by the RNC are out of range. Start / Cancel Degraded In a cell set-up, the cell is set inactive un til valid cell configuration data has been recei ved. In a cell reconfiguration, the cell continues operating with the pre vious configuration data. 7655 CELL NOTIFICATION Blinking red Set the correct power va lues to the RNC.

Detecting unit

Fault source Meaning

Event type Unit status Effect

Reported alarms LED display Instructions 4.30

Commissioning parameter mismatch dn7095963 Issue 1-0 en

(51)

Name Product

Commissioning parameter mismatch Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM A comm issioning parameter does not have a valid value (the parameter is missing or it has a value outside the va lue range) or there are errors in the com missioning file. Start Degraded The BTS capacity may decrease or there may be interference in calls. 7651 BASE STATION OPERATION DEGRADED

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

LED display Instructions

Blinking red Reconfigure the BTS with Commissioning Wizard. 4.31

Communication failure inside WSP

Name Product Communication failure inside WSP Supreme; Optima; Optima IBBU; Opti ma Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSit e, MetroSite 50, Triple-mode: WSP

Detecting unit Fault source

(52)

UltraSite, MetroSite, MetroSite 50, Triple-mode: WSP Meaning An internal communi cation failure be tween the DSP processors. Start / Cancel Out of order The BTS capacity possibly decreases. The Digital Signal Processing (DSP) does not work c orrectly. UltraSite, MetroSite, MetroSite 50, Triple-mode: 7650 BASE STATION FAU LTY (all WSPs are faulty) 7651 BASE STATION OPERATION DEGARDED (at least one wor king WSP) LED display UltraSite, MetroSite, MetroSite 50, Triple-mode: Stable re d UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If only one WSP in the cab inet generates this alarm, the WSP is faulty. 2. If all WSPs in a subrack genera te this alarm, the WAM is faulty. 3. If all WSPs generate this alarm, the WSC/WM C is faulty. Otherwise, check for other alarms. If the "Unit autonomous reset as a recovery action" alarm has occurred for the faulty WSP, replace the faulty WS P unit.

Event type Unit status Effect Reported alarms

Instructions 4.32

Communication failure with RNC

Name Product Communication failure with RNC Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50

dn7095963 Issue 1-0 en # Nokia Corporation 51 (148)

(53)

Detecting unit

UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM UltraSite, MetroSite, Metro Site 50, Triple-mode: WAM, (RNC) The BTS does not receive a response from the RN C (a block request). Transient Working Handing traffic over to another cell may not work. 7652 BASE STATION NOTIFICATION

Fault source Meaning

Event type Unit status Effect Reported alarms

LED display Instructions

Stable green Check the signalling link settings and the RNC connections. 4.33

Default antenna delay value is used for LCS-RTT

Name Default antenna delay value is used for LCS-RTT Supreme; Optima; Optima IBB U; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WAM Loca tion Calculation Service (LCS) uses the default delay values. Start Working The LCS-RTT values are not correct in this cell. Location Calculation Service Round Trip Time (LCS - RTT)

Product

Detecting unit Fault source Meaning Event type Unit status Effect

(54)

Reported alarms

7655 CELL NOTIFICATION LED display Instructions

Check the commissioning file and config uration. 4.34

Difference between BTS master clock and reference frequency

Name Difference between BTS master clock and reference frequency Supreme; Optima ; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WSC/WMC The reference frequency that the BTS master clock receives from the transport part has changed by about 0.2 ppm or more (which equals the change mag ni tude of 204 DAC steps or more) during the measurement period (about 20 min ut es), compared to the BTS master clock frequency. The cause of the alarm can be: 1. The Iub reference frequency has changed due to a fault in the transmission ne twork synchronisation (which in turn is caused by an equipment fault or a settin g error). Note that if the network synchronisation malfunction lasts a long time , the alarm is cancelled when the BTS frequency reaches the faulty Iub synchroni sation. The alarm can also be activated if the faulty Iub synchronisation is cor rected and there is again the difference of 0.2 ppm or more. The alarm is cancel led whenever the difference becomes smaller than 0.2 ppm.

Product

Detecting unit Fault source Meaning dn7095963 Issue 1-0 en

(55)

2. The Iub reference frequency fluctuates continuously due to a great deal of ji tter/wander in the transmission network. The alarm is continuously activated/can celled (however, the alarming state may predominate). There is always some jitte r/wander in the transmission network; the limits are defined in ITUT G.823/824/8 25. 3. If the BTS integrated transport part receives the synchronisation informa tion via the 2.048 MHz synchronisation input (external clock source), the alarm situation may be caused by a fault of that signal. In that case, the alarm behav iour notifications listed with the Iub signal (see above) are also valid in this case. 4. There is an equipment fault in the BTS. The equipment fault is, howeve r, not the most common reason. Normally the reason can be found in the Iub/refer ence signal behaviour (see the descriptions above). Note that if the alarm 7651 BASE STATION OPERATION DEGRADED: 'WSC oven oscillator fault' becomes active, it may cause the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS mast er clock and reference frequency' to cancel. Event type Unit status Effect Start / Cancel Degraded This fault does not immediately affect the operations of the BTS, but it is a noti fication that the BTS frequency deviates from the Iub refe rence. The BTS master clock tuning continues in spite of the alarm, but because the BTS master clock adjustment is quite slow in order to filter the instabiliti es of the Iub interface, it takes some time (even several hours) before the BTS operations start to be af fected. 7652 BASE STATION NOTIFICATION Blinking red (W SC/WMC)

Reported alarms LED display Instructions 54 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(56)

Because there are several possibilities for the alarm activation, a BTS Clock Fr equency History feature has been de veloped. The stored history data can be acce ssed via the BTS Site Manager. The history data can be used as a tool for findin g out the reason for the fault/ alarm situation (for further instructions about the history feature, see the online Help of the BTS Site Manager). Depending on the possible reason, fol low the instructions below: 1. In case of fault in the transmission network synchronisation, the network synchronisation must be correc ted. The long-term accuracy of the Iub signal must be 0.015 ppm or better (check the correct Iub accuracy by measuring it). No actions on the BTS are necessaril y needed. 2. If the basic accuracy of the Iub signal is in order but there is to o much instability, that is, the jitter/wander is outside the acceptable limits, the synchronisation of the transmission network must be corrected. The limits f or the jitter/wander are defined in the ITU-T G.823/824/825. No actions on the B TS are needed. 3. In case of BTS equipment fault, the location may be: a. Transp ort part

.

First check the alarms of the AXC node with the AXC Manager and act accordingly. If there are no alarms, check the AXC synchronisation settings. If both the Iub reference signal accuracy and the AXC node are in order but the WSC unit is sti ll alarming, run the fast tuning with the BTS Site Manager. If the alarm is stil l active after the fast tuning is finished, reset the site. If that does not hel p, replace the WSC unit.

.

b. WSC unit .

. .

(57)

Note that if the reason is in the transmission network synchronisation, replacin g the WSC unit does not correct the situation. Furthermore, the alarm activity ( frequent alarms/ cancels) points to instability in the transmission network, not to a fault in the unit. 4. After the fault situation has been cleared, the BTS master clock may also require tuning because the BTS master clock adjustment is quite slow. The tuning may be done:

.

manually by changing the DAC word (during a site visit) or with fast tuning, in which the BTS master clock is tuned in a few minutes automatically near the Iub reference (normal tuning takes care of the fine tuning). Note, however, that the fast tuning should only be used in case the Iub reference signal is known as a good one. Otherwise the BTS frequency may be tuned into a totally incorrect valu e, causing serious problems in the network performance.

.

Background information: The principle is that in the mobile network, the synchro nisation goes from MSC => RNC => BTS. But in reality that chain might be broken somewhere and, for example, when using leased lines, the BTS may take the refere nce synchronisation from the transmission network of another operator. This does not harm the system if the synchronisation of the leased line service provider is also accurate/stabile enough. The BTS uses the incoming synchronisation signa l as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.

4.35

Diversity branch masthead amplifier fault 56 (148)

(58)

Name Product

Diversity branch masthead amplifier fault Supreme; Optima; Optima IBBU; Optima C ompact RF Extension; MetroSite; Triplemode; MetroSite 50 WAF (WAF), MHA The oper ating voltage of the Mast Head Amplifier (MHA) is supplied through the Bias-T fr om the WAF. The WAF monitors the consumption of the current and gen erates an al arm if it deviates from the normal consumption. The cable between the MHA and WA F is faulty, the Bias-T is faulty, the MHA is faulty or the MHA does not exist. Start Out of order If the MHA is faulty, the RX performance is degraded. The siz e of the cell may be reduced. 7654 CELL OPERATION DEGRADED Alternating red and g reen 1. Check the RF cabling and Bias-T. 2. Check the MHA and WAF units.

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms LED display Instructions 4.36

DSC-bus failure

Name Product DSC-bus failure Supreme; Optima; Optima IBBU; Optima Compact RF Ext ension; MetroSite; Triplemode; MetroSite 50 WAM WAM, WSP

Detecting unit Fault source dn7095963 Issue 1-0 en # Nokia Corporation 57 (148)

(59)

Meaning

There is a failure in the bus between the WAM and WSP (DSC bus), which means tha t messages do not get through via that DSC bus. Start Out of order; Degraded If the source of the fault is at the WSP end of the bus, the DSP capacity de crease s. If the source of the fault is at the WAM end of the bus, it is possible that calls will not get through at all. 7651 BASE STATION OPERATION DEGRADED Blinking red (WAM), Stable red (WSP) Replace the alarming unit.

Event type Unit status Effect Reported alarms

LED display Instructions 4.37

DSP failure in radiolink creation

Name Product DSP failure in radiolink creation Supreme; Optima; Optima IBBU; Opt ima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSi te, MetroSite50, Triplemode: WAM; FlexiBTS: FCM UltraSite, MetroSite, MetroSite 50, Triple-mode: WSP Radiolink creation has failed repeatedly due to DSP rejecti on or no response from the DSP CPU. Start Out of order The BTS capacity may decr ease. 7651 BASE STATION OPERATION DEGRADED

Detecting unit Fault source Meaning

(60)

LED display Instructions

Stable red UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Check the WSP uni ts. 2. Replace the faulty unit.

4.38

Error in commissioning data

Name Product Error in commissioning data Supreme; Optima; Optima IBBU; Optima Co mpact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WTR The WTR initiali sation parameters are faulty. The error can be caused by a missing parameter in the commissioning file: the cabling information (main, diver sity), feeder loss, local cell resources, for example. Start Working The WTR is initialised with th e default va lues. The BTS capacity may decrease or there may be interference in calls. Reported alarms 7651 BASE STATION OPERATION DEGRADED Stable green 1. Che ck that the cell parameters, RX cabling, feeder loss and MHA gain are correct in the commissioning file. 2. Update the information if needed. Reconfiguration co mmissioning is required for correcting the values.

Detecting unit Fault source Meaning Event type Unit status Effect

LED display Instructions dn7095963 Issue 1-0 en # Nokia Corporation 59 (148)

(61)

4.39

Error in file server during SW download

Name Product Error in file server during SW download Supreme; Optima; Optima IBB U; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WAM The BTS is unable to obtain a file from the file server (error in FTP open or FTP ge t). The file server is down, the file is missing, or the path is incorrect. A po ssi ble error in the DCN and Iub, or a user administration error (invalid userna me or password, or the user does not have ac cess rights for the files). Start / Cancel Degraded The BTS continues its operation with the old software. 7652 BAS E STATION NOTIFICATION Blinking red 1. Try to repeat the SW download a few times . 2. Check the FTP account user settings. 3. Check the file and path names. 4. C heck the administration log on the file server.

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms LED display Instructions 4.40

Failure in AXU initialization

Name Product Failure in AXU initialization Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50

60 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(62)

Detecting unit Fault source Meaning

WAM WAM The BTS has lost connection to the AXU or the AXU SW is incompatible. Th e AXU does not respond to requests from the BTS. Start / Cancel Degraded The RNC connection and the remote BTS Site Manager connection will not work. The CNBAP will stay down. The BTS is not operational. 7651 BASE STATION OPERATION DEGRADED Blinking red 1. Check the RNC, AXC or BTS connections/settings. 2. Block/unbloc k the BTS (using the local BTS Site Manager connection if a remote connection is not possible). 3. Reset the AXU or remove/reinsert it. 4. Replace the AXU. Event type Unit status Effect

Reported alarms

LED display Instructions 4.41

Fan module operation degraded

Name Product Fan module operation degraded Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM Supreme: WFA, WPA and WHX fans Optima family: WFA , WPA and WHX fans Triple-mode: WFA, WMP/WTR and WHX fans

Detecting unit Fault source

dn7095963 Issue 1-0 en # Nokia Corporation

(63)

MetroSite, MetroSite 50: WFA fans Meaning A fan does not rotate or rotates slowe r than at the requested speed, or the RPM info is not available for the fan. Sta rt / Cancel Degraded If the redundant fans cannot cool the ca binet sufficiently , a unit overheating may occur. For example, a temperature alarm from the WPA/WM P or WTR may be generated. 7652 BASE STATION NOTIFICATION Stable red 1. Check th e fan ID from the alarm text and locate the problematic fan. See the Fan mapping figures. 2. Check the fan and cabling. 3. If that does not help, replace the WF A, WFD or MFU module or the fan controlled by the WFA, WFD or MFU. Fan control: 'FAN UNIT' refers to a group of fans including the fan control unit. A 'fan' is a single blower.

Event type Unit status Effect

Reported alarms LED display Instructions 4.42

Fatal alarm

Name Product Fatal alarm Supreme; Optima; Optima IBBU; Optima Compact RF Extensi on WAM WOU ARIO has detected a Fatal level alarm. Some ARIO alarms can be cancel led without reset, but most ARIO alarms re quire a WOU block/unblock to cancel. Start / Cancel

Detecting unit Fault source Meaning Event type

62 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(64)

Unit status Effect Reported alarms LED display Instructions

Out of order The related cell is faulty. 7653 CELL FAULTY Stable red Check the W OU or WRUs. Use the ARIO Local Management Tool and Nokia Advanced Indoor Radio u ser docu mentation to diagnose the error cause.

4.43

Fault between WAM and WSP SFN (WSP)

Name Fault between WAM and WSP SFN (WSP) Supreme; Optima; Optima IBBU; Optima Co mpact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, Me troSite 50, Triple-mode: WSP UltraSite, MetroSite, MetroSite 50, Triple-mode: WS P, (WAM) UltraSite, MetroSite, MetroSite 50, Triple-mode: Synchronisation betwee n the WAM and WSP is lost. Start Out of order The BTS capacity possibly decrease s. The Digital Signal Processing (DSP) does not work correctly. UltraSite, Metro Site, MetroSite 50, Triple-mode: 7650 BASE STATION FAULTY (all WSPs are faulty) 7651 BASE STATION OPERATION DEGARDED (at least one working WSP)

Product

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

(65)

LED display

UltraSite, MetroSite, MetroSite 50, Triple-mode: Stable red UltraSite, MetroSite , MetroSite 50, Triple-mode: 1. If only one WSP in the cabinet generates this al arm, the WSP is faulty. 2. If all WSPs in a subrack generate this alarm, the WAM is faulty. 3. If all WSPs generate this alarm, the WSC/WMC is faulty. Otherwise , check for other alarms. If the "Unit autonomous reset as a recovery action" al arm has occurred for the faulty WSP, replace the faulty WSP unit.

Instructions 4.44

Fault in ATM interface

Name Product Fault in ATM interface Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WAM WAM ATM interface is not responding correctly. Start Out of order The BTS capacity decreases. If the mas ter WAM is faulty, the changeover of the master will be done as a recovery a c tion. This will cause a site reset. 7651 BASE STATION OPERATION DEGRADED Stabl e red 1. Block/unblock the faulty unit (this will reset the BTS).

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms

LED display Instructions 64 (148)

(66)

2. If that does not help, replace the faulty unit. 4.45

Fault in ATM interface

Name Product Fault in ATM interface Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WAM WAM ATM interface, AX C or CIF bus fail ure. The AXC may have been reset. A WAM processor failure. Eve nt type Unit status Effect Start Out of order Communication to other WAMs is not functioning. The BTS capacity decreases. The BTS is faulty if the BTS configura tion has only one WAM or all WSPs are under the faulty WAM. Reported alarms 7650 BASE STATION FAULTY (without slave WAM recovery) 7651 BASE STATION OPERATION DE GRADED (several WAMs with WSPs) LED display Instructions Stable red 1. Block/unb lock the faulty unit (this will reset the BTS). 2. Replace the faulty WAM unit. 3. Check the AXU. 4. Check the backplane connection between the WAM and AXU. Detecting unit Fault source Meaning

dn7095963 Issue 1-0 en # Nokia Corporation 65 (148)

(67)

4.46

Fault in OM and DSP SW interface

Name Product Fault in OM and DSP SW interface Supreme; Optima; Optima IBBU; Opti ma Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSit e, MetroSite 50, Triple-mode: WAM UltraSite, MetroSite, MetroSite 50, Triple-mod e: WSPA, WSPC UltraSite, MetroSite, MetroSite 50, Triple-mode: A communication f ailure be tween the WAM and DSP. Start Out of order The Digital Signal Processin g (DSP) does not work correctly. The BTS capa city possibly decreases. 7651 BASE STATION OPERATION DEGRADED Stable red UltraSite, MetroSite, MetroSite 50, Tripl e-mode: 1. Check the other active alarms. 2. Replace the faulty unit.

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

LED display Instructions 4.47

File corrupted in SW download

Name Product File corrupted in SW download Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, Triple-mode , MetroSite, MetroSite 50: WAM

(68)

Fault source

UltraSite, Triple-mode, MetroSite, MetroSite 50: WAM The SW being downloaded is corrupted or incorrectly formed. Start / Cancel Working The BTS continues its op eration with the old software. 7652 BASE STATION NOTIFICATION Stable green 1. Re try the SW update. 2. Fetch BTS log files and check the download status from the BTS SWDL report.

Meaning

Event type Unit status Effect

Reported alarms LED display Instructions 4.48

Flash operation failure

Name Product Flash operation failure Supreme; Optima; Optima IBBU; Optima Compac t RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, MetroSite, MetroS ite 50, Triple-mode: WAM,WTR,WPA/WMP, WSPC,WSPD,WSPE UltraSite, MetroSite, Metro Site 50, Triple-mode: WAM, WTR, WPA/WMP, WSPC, WSPD, WSPE The flash memory opera tion failure. If this alarm appears continuously, the flash chip may be broken. Start Degraded

Detecting unit Fault source Meaning

(69)

BTS memory operations are not stable, for example the software download and para meter updates. Reported alarms UltraSite, MetroSite, MetroSite 50, Triple-mode: 7651 BASE STATION OPERATION DEGRADED (if unit is WAM, WSPC) 7654 CELL OPERATION DEGRADED (if unit is WPA/WMP or WTR) LED display Instructions Blinking red Ultra Site, MetroSite, MetroSite 50, Triple-mode: 1. Check the other active alarms. If the ROM disk is corrupted, change the alarming unit. 2. Block/unblock the fault y unit. There are no recovery actions and due to that the block/unblock can be t ried once. If that does not help, replace the faulty unit.

4.49

Gain adjust alarm

Name Product Gain adjust alarm Supreme; Optima; Optima IBBU; Optima Compact RF E xtension; MetroSite; Triplemode; MetroSite 50 WAM WTR The WTR cannot adjust the TX output power. Start / Cancel Degraded The WTR gain fluctuations cannot be ad justed, which affects the cell output power accuracy. The operation of the re la ted cell is degraded and there may be disturbances or cutoffs in calls.

Detecting unit Fault source Meaning Event type Unit status Effect

68 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(70)

Reported alarms

7654 CELL OPERATION DEGRADED LED display Instructions

Blinking red (WTR) 1. Block/unblock the WTR. The unit needs to be blocked/unbloc ked to get it initialised/configured again if there was an internal failure or s ticking in unit SW. 2. Check the WTR and RF cabling. 3. If that does not help, r eplace the faulty unit.

4.50

Incompatible SW version detected

Name Product Incompatible SW version detected Supreme; Optima; Optima IBBU; Opti ma Compact RF Extension; MetroSite; Triplemode; MetroSite 50 UltraSite, Triple-m ode, MetroSite, MetroSite 50: WAM UltraSite, Triple-mode, MetroSite, MetroSite 5 0: WAM, WTR, WPA/WMP A new unit with an incompatible SW has probably been insert ed in the BTS. Start / Cancel Out of order The resources provided by the unit ca n not be used. 7651 BASE STATION OPERATION DEGRADED (UltraSite, MetroSite, Metro Site 50, Triple-mode: WAM (or un defined)) 7653 CELL FAULTY (UltraSite, MetroSit e, MetroSite 50, Triple-mode: WPA/WMP or the only WTR in the cell)

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

(71)

7654 CELL OPERATION DEGRADED (UltraSite, MetroSite, MetroSite 50, Triple-mode: W TR) LED display Instructions Stable green Update the compatible SW to the BTS (c heck the SW versions to see the ac tive SW version, and update the active SW ver sion), unless it is automatically updated by the NetAct.

4.51

Incompatible unit detected

Name Product Incompatible unit detected Supreme; Optima IBBU; Optima Compact RF Extension; MetroSite 50 WAM WSMA, (WTRA, WSPA), WMCM MetroSite 50/WN3.0: WMCM12, WTRB An unsupported unit (for example a WSMA, WTRA, WSPA, WMCM or WTRB) has bee n detected in the cabi net. Start Out of order The BTS is faulty or the capacity is de creased. 7650 BASE STATION FAULTY (WMC) 7651 BASE STATION OPERATION DEGRA DED (WSP, MetroSite 50) 7653 CELL FAULTY (WSM, WTR) LED display Instructions Sta ble red Replace the unsupported unit with a unit of the correct type.

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms

70 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(72)

4.52

Initial calibration not started because other cell not cleared

Name Initial calibration not started because other cell not cleared Supreme; Opt ima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WTR There is a shared WPA/WMP in the con figuration (WPA serves two cells ). The first cell needs to be calibrated and there fore the second active cell n eeds to be cleared, but the clearing fails. Start / Cancel Degraded The initial power level of the cell is inac curate. Continuous calibration is not per formed . The cell size may differ from the planned coverage. 7654 CELL OPERATION DEGRAD ED Blinking red 1. Block/unblock the cell. The unit needs to be blocked/unblocke d to get it initialised/configured again if there was an internal failure or sti cking in unit SW. 2. Check the other active alarms.

Product

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms LED display Instructions 4.53

Invalid carrier in WTR

Name Product Invalid carrier in WTR Supreme; Optima; Optima IBBU; Optima Compact RF Extension; MetroSite; Triplemode; MetroSite 50

dn7095963 Issue 1-0 en # Nokia Corporation

(73)

Detecting unit Fault source Meaning

WAM WTR There was an attempt to set the WTR to a channel not supported by the WT R (on a different frequency band). Start / Cancel Out of order The related cells are disabled. 7653 CELL FAULTY Stable red 1. Make sure that correct carrier num bers are in use in the RNC. 2. Commission the BTS with the correct WCDMA carrier values for the WTR.

Event type Unit status Effect Reported alarms LED display Instructions 4.54

Invalid frequency channel for the BTS HW

Name Invalid frequency channel for the BTS HW Supreme; Optima; Optima IBBU; Opti ma Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WAM WTR, WPA, WIC, WAF, WMP The requested channel in the cell set-up is not acceptable, that is, th e frequency band and/or the carrier spacing and/or the number of carriers is/are not accepta ble for the BTS HW. Transient Working The BTS capacity possibly dec reases.

Product

Detecting unit Fault source Meaning Event type Unit status Effect

72 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

(74)

Reported alarms LED display Instructions

7655 CELL NOTIFICATION Stable green Check the RNC cell parameters against the BT S HW configuration. The cell fre quency is out of the minimum/maximum limit of t he HW, or the number of carriers for the HW type is exceeded, or the car rier sp acing limit is exceeded. There are different type variations of the HW that may have limitations in the supported fre quency range and bandwidth.

4.55

LPA faulty

Name Product LPA faulty Supreme; Optima; Optima IBBU; Optima Compact RF Extensio n; MetroSite; Triplemode WPA/WMP WPA/WMP The unit is broken, because the startup self-test fails, the FPGA file downloading from flash fails, or the synthesiser is mal functioning. This fault can only occur in the self-test phase. Start Out of order The unit does not operate. The related cell becomes faulty. 7653 CELL FAULTY Stable red 1. Block/unblock the WPA/WMP. 2. Check the faulty unit. 3. If that does not help, replace the WPA/ WMP.

Detecting unit Fault source Meaning Event type Unit status Effect

Reported alarms LED display Instructions dn7095963 Issue 1-0 en

# Nokia Corporation 73 (148)

(75)

4.56

LPA gain fault

Name Product LPA gain fault Supreme; Optima; Optima IBBU; Optima Compact RF Exte nsion; MetroSite; Triplemode; MetroSite 50 WPA/WMP WPA/WMP A malfunction in some part of the ampli fier, which therefore cannot perform the specified gain. Star t / Cancel Degraded The BTS capacity possibly decreases. 7654 CELL OPERATION DEG RADED Blinking red 1. Block/unblock the WPA/WMP. 2. Check the faulty unit. If th at does not help, replace the WPA.

Detecting unit Fault source Meaning

Event type Unit status Effect Reported alarms LED display Instructions 4.57

LPA input signal level is too high

Name Product LPA input signal level is too high Supreme; Optima; Optima IBBU; Op tima Compact RF Extension; MetroSite; Triplemode; MetroSite 50 WPA/WMP, WOU WPA/ WMP, (WTR), WOU The input signal level from the WTR is critically high. The LPA gain is too low. Start

Detecting unit Fault source Meaning Event type

74 (148)

# Nokia Corporation dn7095963 Issue 1-0 en

References

Related documents