• No results found

TO evolution. The result of 35 years of development and application

N/A
N/A
Protected

Academic year: 2021

Share "TO evolution. The result of 35 years of development and application"

Copied!
16
0
0

Loading.... (view fulltext now)

Full text

(1)

www.to-evolution.com

www.to-evolution.com

www.to-evolution.com

www.to-evolution.com

(2)

1980 1985 1995 2005 2000 1995 1990 1985

2015

In 2010 the two most successful and well-known olfactometer

manufacturers, ecoma and Odournet, merged with the aim to combine their experience and knowledge to focus on the development of the best and latest technologies for odour measurement.

The TO evolution and WiNose evolution LIMS are the results of this mission. They merge the best technology of the TO-series with the WiNose olfactometer LIMS software, which was designed specifi cally for odour laboratories.

(3)

easy to maintain

process optimizing ergonomical

We consider ourselves not only manufacturers, but fi rst and foremost daily users of the technology. This understanding allows us to focus on what really benefi ts you during your day-to-day operations in the odour laboratory. At the same time we continuously seek the opinions of our customers, as user feedback is essential for us to continuously improve our products.

As the supplier of more than 250 equipped laboratories in more than 40 countries, Odournet is your No.1 in odour measurement technology!

With six accredited laboratories throughout Europe we fully understand the challenges faced by odour laboratories. Our goal is to give you the best support to be able to meet the constantly growing requirements for quality management and traceability.

(4)

1. Removable and replaceable dilution unit

The dilution unit is delivered as a compact mountable box, which you can quickly and easily slot into place. With this option, you can reduce your transportation costs when calibration or maintenance is required as you do not have to ship the entire olfactometer The TO evolution allows for easy setup and is simple to maintain due to its new modular design; you can be

assured of the reliability of our well-known robust equipment, manufactured in-house in Germany.

2. Support bar with partition screens

The support bar provides the foundation for the other elements of the TO evolution and contains the air distribution lines to the panel interface ports. The partition screens can be mounted within seconds.

3. Panel interface ports

The panel interface ports can be equipped with two nose masks and have a high resolution touch screen interface which allows panellist feedback forms to be customised depending on the analytical method being used. Thanks to the “easy click” system, the panel interface ports are easily attached to the support bar. The hardware and software will detect the station automatically without the need for further programming.

(5)

The heart of the TO evolution is the ultra-modern and purpose designed dilution system, which is based on the proven principle of combining gas jet pumps and fi xed sapphire orifi ces.

These technologies are already well-known from the TO8, the TO8s, the TO9 and the TO8-8 olfactometers. Developing a new motherboard and more powerful motors was the logical progression of the technology. At the same time, we focused on keeping the size of the dilution unit as compact as possible to allow for fast and effi cient service at low transportation cost. With a new reverse fl ushing option the dilution system can also be fl ushed in reverse to remove even the smallest particles that could be blocking an orifi ce.

(6)

Based on our experience we know that diff erent odour

laboratories have diff erent requirements for their olfactometer. The TO evolution is the fi rst “one-size-fi ts-all” olfactometer in the world:

Thanks to its modular design, the TO evolution is scalable for up to 6 panellist stations. You can decide for yourself which is most suitable for your requirements; whether it’s a 2-station, 4-station or 6-station olfactometer.

The TO evolution is designed for the following methods:

Yes / No (EN 13725:2003)

Dual Forced Choice (EN13725:2003) Triangular Forced Choice (ASTM 679) Intensity (VDI 3882 Part1)

Hedonic Tone (VDI 3882 Part2)

(7)

The TO evolution is the fi rst ergonomically designed olfactometer which focuses on the main sensor in olfactometry: the human nose. Olfactometry is a human sensory measurement method in which the panellists play a central role. That is why our engineers have collaborated with professional industrial designers to focus on the interaction between man and machine. The result is an olfactometer which, through the selection of materials and colours, off ers the panellists a distraction-free environment. The modern and contemporary design of the software allows for intuitive and easy operation.

These essential characteristics of the new TO evolution ensure that you can achieve best working conditions as described in the requirements of EN 13725:2003.

max. height min.

FOCUS ON THE HUMAN SENSOR

The height-adjustable nose masks allow the panellists to always sit in the optimal upright position, regardless of how tall they are. The centrally-located touch screen is easily accessible and suitable for both for right- and left-handed users.

(8)

The TO evolution software package provides an olfactometer control software to support your laboratory in delivering odour measurements at the highest quality: The TO evolution control software supports all relevant standards such as EN 13725:2003, AS 4323.1, ASTM 679, VDI 3882 Part 1 & Part 2. With its modern look and feel, and user friendly interface, the TO evolution software ensures fast and reliable measurements without overloading the user with operational information. Regardless of the level of experience of your operators, from the novice through

to the highly experienced, the TO evolution software can give them the guidance and visual assistance that is needed to ensure measurements at the highest quality.

TO EVOLUTION CONTROL SOFTWARE

How you benefi t:

Operator interface Panellist interface - Hedonic Tone

Panellist interface - Dual Forced Choice

• Improved usability for operators through a state-of-the-art user interface

• Extended checkup features and test routines • Real-time acquisition of data

• Integrated WiNose evolution LIMS interface ensures all results are instantly available in the LIMS and accessible to the users • Direct transmission of results to the WiNose

evolution LIMS reduces the steps in producing documentation, and avoids error-prone manual copying & pasting of data • Keep the software up to date with the

automated update mechanism (requires an active internet connection)

(9)

The TO evolution software package provides a

dedicated Laboratory Information Management System (LIMS) for odour labs which supports your laboratory in the process of delivering odour measurements of the highest quality.

Quality management and quality control is essential for any olfactometry lab. The WiNose evolution LIMS supports you in managing and controlling the quality of your measurements by providing many useful laboratory management tools. From qualifying your

panel and keeping track of your lab performance, to managing reference gases, projects and clients, the WiNose evolution LIMS off ers various options to support your day-to-day laboratory processes. Full traceability of changes made to the LIMS database allow for stress-free audits with accreditation bodies.

WINOSE EVOLUTION LIMS (LABORATORY INFORMATION MANAGEMENT SYSTEM)

LIMS - Panelist history

(10)

How you benefi t:

LIMS features:

GET TO KNOW YOUR NEW ODOUR LABORATORY MANAGEMENT ASSISTANT

Project Management Client Management User Management Sample Management Sample Bag Management Panelist Management Reference Gas Management Certifi cate generation Olfactometer Management

• Improve your data availability through web-based access within your network

• Improve your data quality through reduced transcription errors

• Save valuable time in lab operation and management through centralized management and dedicated tools for quality management and reporting

• Find data quickly with our advanced full-text search options

• Reduce the eff ort of accreditation audit preparation

• Increase effi ciency through centralized user access via a web-interface

(11)

1

2 3

4 ISO 17025

Whenever a calibration or maintenance in accordance with ISO 17025 is required, the dilution unit can be easily and quickly removed from the support bar for transportation. A dedicated transport box ensures the safe shipment of the unit to the Odournet calibration laboratory. This also saves on the potential costs incurred on-site calibration by a calibration technician.

If desired you can reserve a replacement unit for the duration of your calibration or maintenance which we send to you in advance, minimizing the downtime of your laboratory. All dilution units are calibrated according to the requirements of ISO 17025 and provided with a certifi cate to demonstrate compliance to your accreditation body. Odournet is an accredited laboratory for measurement to ISO 17025 and we know that quality management is the key to success.

(12)

Rely on our logistical expertise

With over 35 years of experience, more than 250 delivered olfactometers in 40 countries and an average of 80 in-house calibrations per year, we can off er you a consistent and reliable logistics process.

Full service guarantee

We can take over the entire logistics process for you. Whether you have technical problems or are due calibrations, our Customer Service Department can support you throughout the entire process and will keep you informed at every step along the way. We can work with you to schedule the collection and return of your instrument and provide tracking information up to its arrival in your laboratory.

24 month repair service

Thanks to the Odournet Repair Service we prolong the usual B2B warranty period of 12 months, giving you the right to claim for defects up to the end of the fi rst 24 months. If a repair is necessary within this period, the costs will be covered.

BENEFIT FROM THE BEST POSSIBLE

SERVICE AND SUPPORT

Receiving fast and reliable support is essential for our customers if problems occur. With our Helpdesk we can off er you a single point of contact for fast and effi cient help in solving your problems. Contact [email protected] to receive a support ticket, and our Service & Support team will get in contact you ASAP.

(13)

b) assembled 4 - Place b) assembled 6 - Place Dilution principle

Vent for surplus diluted odour

Number of panel members working simultaneously Analyses time for one sample

(according to EN 13725:2003) Dilution range

Interval steps Dilution accuracy Response/setting time Required sample volume

Material in contact with sample Contamination protection Cleaning

Air consumption

b) 1370 x 900 x 550 mm – 43.1 kg c) 1965 x 900 x 550 mm – 57.5 kg

Gas jet pumps and calibrated precision orifi ces for sample dosage Outlet air via active carbon filter

2, 4 or 6

5 min ( with 4 or 6 panel members working simultaneously) 2² (1:4) - 217 (1:131,058) – yes/no method

2³ ( 1:8) - 217 ( 1:131,058) – dual-forced-choice method 2² (1:4) - 217 (1:131,058) - triangular-forced-choice method Factor √2 (1.4) - 31 dilution steps

Factor 2 - 16 dilution steps < 5%

< 0.1 sec

~ 500 OU/m³ - 1l (yes/no), 3.5l (d-f-c) * ~ 64 OU/m³ - 3l (yes/no), 14.5l (d-f-c) * <16 OU/m³ - 10l (yes/no), 54l (d-f-c) * Stainless Steel, PTFE(Tefl on®), Glass (only with glass nose masks)

All TO-series Olfactometers are equiped with a stream of blocking air between the current of sample air and the current of reference air. All TO-series Olfactometers have a current of fl ushing air to fl ush the sample air duct. The fl ushing period is freely selectable. Heatable dilution system make it possible to heat treat the sample air duct.

4 port and 1 cup about 100l/min, 4 port and 2 cups about 180 l/min, 6 port and 1 cup about 160 l/min, 6 port and 2 cups about 240 l/min *(estimation with default settings)

(14)

(does not come with the system) Pressure regulation

Input voltage

Power consumption (incl. Heating) Software

Hardware requirements (Notebook / Desktop) Operating system

Languages Nose masks

Air speed (V) in the nose mask supplied with air Current of air out of the nose mask

Presentation times for the sample air and respiratory cycle frequency

Temperature presented at the nose mask Pressure on the sample

Maximum calibration interval Warranty

Fixed settings

110 - 240 V AC 50/60 Hz, power device 24 V 200 Watt

TO-evolution software including Laboratory Management From Dual CoreDual-Core Processor with at least 1.2Ghz, 2GB RAM, 10GB free hdd spac, 10 GB hard disk space Windows: Windows 7, Windows 8 (32/64-Bit)

German, English, French, Spanish, NL and all other languages can be provided within a short period of time. Ergonomic, cone-shaped nose masks

0.2 m/s < V < 0.5 m/s 20 l/min

Freely selectable

+/- 1°C of the ambient temperature No pressure is applied to the sample 12 months (according to EN 13725:2003)

(15)

YOUR BENEFITS

OLFACTOMETER TEST OPTIONS

SCOPE OF DELIVERY

OPTIONAL

VISUALIZES MEASUREMENT WORKFLOW

• Manual dilution settings • Panel feedback

• Hardware tests

• 2 (2 place y/no method) up to 12 nose masks (6 place d-f-c method) • Filter system

• 2 x 5 m PTFE compressed air tube • 1 x pressure reducer

• Pelikan Transport box (for the dilution unit) • 50 x 10 l bags

• 1 x 10 CAD5 E network cable

• Calibration certifi cate in accordance with ISO 17025 • WiNose evolution LIMS

• TO evolution controlling software including intensity and hedonic tone • 24 months of warranty

• Long life after sales support

• Sample bags of Nalophan® • Transport box

• Nose funnels

• Sampling device standard • Sampling device CSD30

• Ventilated sampling hood • Pre dilution system EPD • Pre dilution device GSP • Medic air compressor • Notebook in your language • Animated models and schemes of measurement workfl ows

• Made by olfactometry experts for olfactometry experts • Easy setup and installation

• Save time in quality management processes

• Deliver high quality measurements for your clients in less time • Helps your lab to prepare for accreditation audits

(16)

Odournet develops, manages and delivers top level expertise on sensory analysis techniques and their application in environmental nuisance management as well as product optimisation and material testing.

Odournet aims to be a worldwide leader and innovator in its specialist areas of expertise in terms of depth of knowledge, quality and service delivery to clients.

Odournet strives to respect and balance the interests of People, Planet and Profi t.

Odournet strives to provide opportunities for its dedicated and specialised staff members to develop in a full career cycle, both in intellectual and organisational scope and fi nancially.

Odournet GmbH

Fraunhoferstr. 13 24118 Kiel Germany phone: +49 431 22012-0 fax: +49 431 22012-17 [email protected] www.odournet.com www.to-evolution.com

CONTACT ODOURNET

References

Related documents

Compared to greater Pakistan, the FATA is suffering from lower levels of investment in health capital, education and economic development?. All of these factors contribute to

Online community: A group of people using social media tools and sites on the Internet OpenID: Is a single sign-on system that allows Internet users to log on to many different.

O objetivo deste trabalho foi avaliar a força de músculos ventilatórios e de mão em pacientes na lista de espera para o transplante de fígado e associá-los à

Other than caries removal, this is a range of other well established laser hard tissue procedures include desensitization of cervical dentine (using Nd:YAG, Er:YAG, Er,Cr:YSGG CO2,

accuracy with which pediatricians are able to estimate the patients’ intelligence, in comparison with the results of standard psychologic tests, and the factors that in-..

(Right triangles are congruent if any two sides are congruent because of the Pythagorean relationship, which guarantees that the third sides are also congruent.) This shows that

This type of analysis leads to the optimization of the control parameters of an experimental microfluidic device with application in the separation of submicron particles..

Figure 7: Aerial view of the green reflectance map from 6-15 site 1 with prickly pear locations circled in red.. Figure 8: Aerial view of the near infrared reflectance map from