4.7%
BLOCK 207 BLOCK 206
1850 2650
4650 1650 1790
1100 1600 4345
8155 1750
2800
1800 3300 1800
1400 1100
6.67% 6.67% 6.67%
3000
2340
4000
BLOCK 206 MIWATE PRIVATE
BLOCK 206
HEAD STREET SQUARE
GARAGE INTAKE
GARAGE INTAKE CAST IN PLACE
CONCRETE SITTING WALL WITH WOOD TOP
UNIT PAVING
L5.0
01
VEHICULAR
CONCRETE PAVING
L5.0
05
SALVAGED PULPER
·
BY OTHERS
UNIT PAVING
L5.0
01
BLOCK 206 LIMIT OF WORK TEMPORARY ASPHALT PAVING
·
EXTEND TO BACK OF CONCRETE ROAD CURB
L5.0
07
CAST IN PLACE CONCRETE RAMP WITH CURBS
UNIT PAVING
L5.0
01
BLOCK 206 LIMIT OF WORK TEMPORARY
ASPHALT PAVING 07
L5.0
CAST IN PLACE CONCRETE STAIRS AND LANDING 02
L5.1
CAST IN PLACE CONCRETE RAMP
·
REFER TO CIVIL FOR GRADING
STAINLESS STEEL HANDRAIL
L5.1
01 VEHICULAR
CONCRETE PAVING
L5.0
05 PEDESTRIAN
CONCRETE PAVING
L5.0
04
PEDESTRIAN
CONCRETE PAVING
L5.0
04 PEDESTRIAN
CONCRETE PAVING
L5.0
04 3675
CAST IN PLACE CONCRETE RAMP WITH CURBS
STAINLESS STEEL HANDRAIL
L5.1
01 STAINLESS STEEL
HANDRAIL 01
L5.1
PEDESTRIAN
CONCRETE PAVING
L5.0
04
319 McRae Avenue, Suite 502, Ottawa, Ontario, K1Z 0B9 Tel: (613) 729-4536
No. Revision Date
Project:
Drawing:
Scale:
Design By: Drawn By:
Date:
Stamp:
North:
Landscape Architecture Urban Design
Site Planning
Recreation and Park Planning Project Management
1. All measurements in millimeters unless specified otherwise.
Do not scale drawing. All drawings to be read in conjunction with written specifications.
2. Copyright reserved. This drawing is the exclusive property of CSW Landscape Architects Ltd. and shall not be used without the consent thereof.
3. This Drawing may not be used for construction until signed by the landscape architect. It is the responsibility of the contractor to:
·check and verify all dimensions on site;
·report all errors and/or omissions to the landscape architect;
·comply with all pertinent codes and by-laws;
·check and verify locations of all underground services with all local utilities prior to any digging.
ISSUED FOR SITE PLAN APPROVAL
1 JUNE 18, 2020
Zibi Ontario BLOCK 206
CHAUDIERE PRIVATE WEST OTTAWA, ONTARIO
LANDSCAPE PLAN Ground Floor
PLANT LIST
KEY BOTANICAL NAME COMMON NAME QTY SIZE REMARKS
DECIDUOUS TREES
AC AMELANCHIER CANADENSIS SERVICEBERRY 3 50mm CAL. MULTI-STEM
PERENNIALS
PH PENSTEMON HIRSUTUS HAIRY BEARDTONGUE 50 1 GAL. 0.35 O.C
GRASSES
CA CALAMAGROSTIS CANADENSIS CANADA BLUEJOINT 50 1 GAL. 0.6 O.C SH SPOROBOLUS HERTEROLEPIS PRAIRIE DROPSEED 75 1 GAL. 0.4 O.C
SN SORGHASTRUM NUTANS INDIAN GRASS 25 1 GAL. 0.4 O.C
NOTES:
·
PLANTING LAYOUT TO BE REVIEWED AND APPROVED BY LANDSCAPE ARCHITECT PRIOR TO PLANTING
·
MIX PERENNIALS TOGETHER IN GROUPS OF 3-5 OF SAME SPECIES
·
MIX GRASSES TOGETHER IN GROUPS OF 4-7 OF SAME SPECIES
1800
PRECAST CONCRETE
TILES 08
L5.0
OVERHEAD TRELLIS
GREEN ROOF PLANTING (TYP), 6" DEPTH
·
REFER TO SPECIFICATIONS
·
INSTALL AS PER MANUFACTURER INSTRUCTION AND APPROVED SHOP DRAWINGS
LARGE PLANTER (TYP) FURNITURE BY OTHERS
OUTDOOR GRILLING
STATION (4) OUTDOOR DINING AREA
·
FURNITURE BY OTHERS
OVERHEAD TRELLIS
EDIBLE GROWING SPACE, COMMUNITY GARDEN
·
LIVE ROOF MAX, 8"
DEPTH UNPLANTED
GREEN ROOF PLANTING (TYP), 6" DEPTH
·
REFER TO SPECIFICATIONS
·
INSTALL AS PER MANUFACTURER INSTRUCTION AND APPROVED SHOP DRAWINGS
LARGE PLANTER (TYP)
PRECAST CONCRETE
TILES 08
L5.0
3600
6600
3000 4200
1200 4200
3000
4800 4200
1200
1170 1200 1800 3600 1200
3600
5400 3000 3000
6000
GROUP FITNESS AREA (Yoga, Classes etc.)
ELEVATED, MULTI-PURPOSE PLATFORM, DECKING
(Fitness instruction, Music, Classes etc.)
319 McRae Avenue, Suite 502, Ottawa, Ontario, K1Z 0B9 Tel: (613) 729-4536
No. Revision Date
Project:
Drawing:
Scale:
Design By: Drawn By:
Date:
Stamp:
North:
Landscape Architecture Urban Design
Site Planning
Recreation and Park Planning Project Management
1. All measurements in millimeters unless specified otherwise.
Do not scale drawing. All drawings to be read in conjunction with written specifications.
2. Copyright reserved. This drawing is the exclusive property of CSW Landscape Architects Ltd. and shall not be used without the consent thereof.
3. This Drawing may not be used for construction until signed by the landscape architect. It is the responsibility of the contractor to:
·check and verify all dimensions on site;
·report all errors and/or omissions to the landscape architect;
·comply with all pertinent codes and by-laws;
·check and verify locations of all underground services with all local utilities prior to any digging.
ISSUED FOR SITE PLAN APPROVAL
1 JUNE 18, 2020
Zibi Ontario BLOCK 206
CHAUDIERE PRIVATE WEST OTTAWA, ONTARIO
LANDSCAPE PLAN Level 03
PLANT LIST
Live Roof GREEN ROOF SYSTEM
LiveRoof Cold Extreme Mix LiveRoof Giants Mix
LiveRoof School Pride Mix
LiveRoof RoofStone PAVER
·
INSTALL AS PER MANUFACTURER INSTRUCTIONS
MAINTENANCE EDGE (TYP)
900
6000 900 3000 3000
4050 4050
1800
910
16495 1170
GREEN ROOF PLANTING (TYP), 6" DEPTH
·
REFER TO SPECIFICATIONS
·
INSTALL AS PER MANUFACTURER INSTRUCTION AND APPROVED SHOP DRAWINGS
319 McRae Avenue, Suite 502, Ottawa, Ontario, K1Z 0B9 Tel: (613) 729-4536
No. Revision Date
Project:
Drawing:
Scale:
Design By: Drawn By:
Date:
Stamp:
North:
Landscape Architecture Urban Design
Site Planning
Recreation and Park Planning Project Management
1. All measurements in millimeters unless specified otherwise.
Do not scale drawing. All drawings to be read in conjunction with written specifications.
2. Copyright reserved. This drawing is the exclusive property of CSW Landscape Architects Ltd. and shall not be used without the consent thereof.
3. This Drawing may not be used for construction until signed by the landscape architect. It is the responsibility of the contractor to:
·check and verify all dimensions on site;
·report all errors and/or omissions to the landscape architect;
·comply with all pertinent codes and by-laws;
·check and verify locations of all underground services with all local utilities prior to any digging.
ISSUED FOR SITE PLAN APPROVAL
1 JUNE 18, 2020
Zibi Ontario BLOCK 206
CHAUDIERE PRIVATE WEST OTTAWA, ONTARIO
LANDSCAPE PLAN Level 09
PLANT LIST
Live Roof GREEN ROOF SYSTEM
LiveRoof Cold Extreme Mix LiveRoof Giants Mix
LiveRoof School Pride Mix
PRECAST CONCRETE
TILES 08
L5.0
OUTDOOR GRILLING STATION
OUTDOOR DINING AREA
·
FURNITURE BY OTHERS OUTDOOR GRILLING
STATION
OUTDOOR DINING AREA
·
FURNITURE BY OTHERS
LOUNGE FURNITURE BY OTHERS
PRECAST CONCRETE TILES
LOUNGE FURNITURE BY OTHERS
L5.0
08
319 McRae Avenue, Suite 502, Ottawa, Ontario, K1Z 0B9 Tel: (613) 729-4536
No. Revision Date
Project:
Drawing:
Scale:
Design By: Drawn By:
Date:
Stamp:
North:
Landscape Architecture Urban Design
Site Planning
Recreation and Park Planning Project Management
1. All measurements in millimeters unless specified otherwise.
Do not scale drawing. All drawings to be read in conjunction with written specifications.
2. Copyright reserved. This drawing is the exclusive property of CSW Landscape Architects Ltd. and shall not be used without the consent thereof.
3. This Drawing may not be used for construction until signed by the landscape architect. It is the responsibility of the contractor to:
·check and verify all dimensions on site;
·report all errors and/or omissions to the landscape architect;
·comply with all pertinent codes and by-laws;
·check and verify locations of all underground services with all local utilities prior to any digging.
ISSUED FOR SITE PLAN APPROVAL
1 JUNE 18, 2020
Zibi Ontario BLOCK 206
CHAUDIERE PRIVATE WEST OTTAWA, ONTARIO
LANDSCAPE PLAN
Level 25
Scale 1:10
UNIT PAVING ON GRANULAR BASE
01
LEVELING COURSE
· REFER TO SPECIFICATIONS COMPACTED GRANULAR 'A' TO 95% SPD
UNIT PAVERS
· REFER TO SPECIFICATIONS
· REFER TO LAYOUT FOR TYPE AND EXTENTS
UNDISTURBED SUBGRADE OR COMPACTED FILL AS
APPROVED BY GEOTECHINCAL ENGINEER
150
Scale 1:10
UNIT PAVING ON ROOF SLAB
02
LEVELING COURSE
· REFER TO SPECIFICATIONS COMPACTED GRANULAR 'A' TO 95% SPD
UNIT PAVERS
· REFER TO SPECIFICATIONS
· REFER TO LAYOUT FOR TYPE AND EXTENTS
ROOF ASSEMBLY
· REFER TO ARCHITECTURAL
80
100 MIN
NOTES:
1. MINIMUM 50mm COMPACTED GRANULAR BASE REQUIRED.
CONTROL JOINT (CJ) EXPANSION JOINT (EJ) NOTES:
1. REFER TO DRAWINGS FOR JOINT LAYOUT 2. SAWCUT WITHIN 48 HOURS OF POUR 3. NO TOOLED EDGES
10M x 600mm SMOOTH STEEL DOWELS 300mm O.C. GREASE AND SLEEVE ONE END
BIT. FIBRE EXPANSION BOARD, MAX WIDTH 10mm
CAST-IN-PLACE CONCRETE TYPICAL SAWCUT
14 DEPTH OF SLAB 25mm MINIMUM
NOTES :
1. REFER TO DRAWINGS FOR JOINT LAYOUT 2. NO TOOLED EDGES
Scale 1:10
CONCRETE JOINTING
03
FINISHED GRADE CAST-IN-PLACE CONCRETE
· BROOM FINISH
· NO TOOLED EDGES 150x150 WELDED WIRE MESH
COMPACTED GRANULAR
`A` TO 98% SPD
UNDISTURBED SUBGRADE OR COMPACTED FILL AS APPROVED BY THE GEOTECHNICAL ENGINEER
150 100
150 MIN
Scale 1:10
PEDESTRIAN CONCRETE PAVING
04
FINISHED GRADE
CAST-IN-PLACE CONCRETE
· BROOM FINISH
· NO TOOLED EDGES
· REFER TO CONCRETE JOINT DETAIL
COMPACTED GRANULAR
`A` TO 98% SPD
UNDISTURBED SUBGRADE OR COMPACTED FILL AS APPROVED BY GEOTECHNICAL ENGINEER
200
150 MIN
Scale 1:10
VEHICULAR CONCRETE PAVING
05
300
COMPACTED GRANULAR
`B` TO 98% SPD 15M - 250mm O.C
15M - 500mm O.C
Scale 1:10
ROOF DRAIN AT GREEN ROOF
09
600TYP
ROOF DRAIN COVER AS MANUFACTURED BY LiveRoof
· REFER TO SPECIFICATIONS
ROOF ASSEMBLY
· REFER TO ARCHITECTURAL ROOF SLAB
ROOF DRAIN
· REFER TO ARCHITECTURAL AND MECHANICAL FOR ADDITIONAL DETAILS AND SPECIFICATIONS
FILTER FABRIC
Scale 1:10
PRECAST CONCRETE TILES
08
PEDESTAL SUPPORT WITH 4.5mm SPACERS
· REFER TO SPECIFICATIONS
· INSTALL AS PER MANUFACTURER INSTRUCTIONS PRECAST CONCRETE TILES
· REFER TO SPECIFICATIONS FOR PAVER SIZE AND COLOUR
ROOF ASSEMBLY
· REFER TO ARCHITECTURAL ROOF SLAB
125
100
PRECAST CONCRETE CURB
· REFER TO LAYOUT FOR LOCATIONS
· SHIM/PAD PRECAST EDGER TO ACCOMMODATE SLOPING INSULATION AND FINISHED GRADE
FILTER FABRIC GREEN ROOF PLANTING
· REFER TO SPECIFICATIONS
· INSTALL AS PER MANUFACTURER INSTRUCTIONS AND APPROVED SHOP DRAWINGS
Scale 1:10
TEMPORARY ASPHALT PATHWAY
07
SLOPE 2%
50mm HL3 ASPHALT
· REFER TO LAYOUT FOR WIDTH AND LOCATION 100
MIN
UNDISTURBED SUBGRADE OR COMPACTED FILL COMPACTED GRANULAR
`A` TO 98% SPD
50
150 MIN
ENSURE POSITIVE DRAINAGE
Scale 1:20
BICYCLE PARKING
06
BIKE RACK
· REFER TO SPECIFICATIONS
· REFER TO LAYOUT PLAN FOR LOCATION AND SPACING
INSTALL AS PER MANUFACTURER
· CORE DRILL 75mm HOLES, 150mm DEPTH
· SECURE IN PLACE WITH ANCHORING CEMENT COMPACTED GRANULAR 'A' TO 98% SPD
CONCRETE PAVING
ROOF ASSEMBLY
· REFER TO ARCHITECTURAL
TOP OF ROOTBALL TO RETAIN SAME RELATION TO FINISHED GRADE AS PER PREVIOUS EXISTING GRADE
PRUNE DEAD OR BROKEN BRANCHES ONLY
· REMOVE ALL BURLAP WRAP, RIBBONS AND TAGS
300mm PLANTING SOIL MIX AS SPECIFIED SCARIFY WALLS AND BOTTOM OF PIT 100mm SOIL SAUCER 50mm MULCH LAYER
COMPACTED FILL OR UNDISTURBED SUBGRADE
NOT TO SCALE
SHRUB / PERENNIAL PLANTING
10
COMPACTED FILL, PLANTING SOIL OR UNDISTURBED SUBGRADE
TAMP BOTTOM OF TREE PIT PLANTING SOIL MIX AS SPECIFIED SCARIFY WALLS OF PIT
150mm SOIL SAUCER 75mm MULCH LAYER
TOP OF ROOTBALL TO RETAIN SAME RELATION TO FINISHED GRADE AS PER PREVIOUS
EXISTING GRADE
▪ REMOVE BURLAP AND WIRES FROM ROOTBALL
USE 2-1800mm STEEL STAKES PLACED AWAY FROM ROOTBALL AS SHOWN
▪ SECURE WITH ARBORTIE OR APPROVED EQUAL DO NOT DAMAGE OR CUT LEADER
· PRUNE DEAD OR BROKEN BRANCHES ONLY
· REMOVE ALL BURLAP WRAP, RIBBONS AND TAGS
TREE PIT WIDTH MIN 2X ROOT BALL DIA.
NOT TO SCALE
TREE PLANTING
11
AS NOTED
319 McRae Avenue, Suite 502, Ottawa, Ontario, K1Z 0B9 Tel: (613) 729-4536
No. Revision Date
Project:
Drawing:
Scale:
Design By: Drawn By:
Date:
Stamp:
North:
Landscape Architecture Urban Design
Site Planning
Recreation and Park Planning Project Management
1. All measurements in millimeters unless specified otherwise.
Do not scale drawing. All drawings to be read in conjunction with written specifications.
2. Copyright reserved. This drawing is the exclusive property of CSW Landscape Architects Ltd. and shall not be used without the consent thereof.
3. This Drawing may not be used for construction until signed by the landscape architect. It is the responsibility of the contractor to:
·check and verify all dimensions on site;
·report all errors and/or omissions to the landscape architect;
·comply with all pertinent codes and by-laws;
·check and verify locations of all underground services with all local utilities prior to any digging.
ISSUED FOR SITE PLAN APPROVAL
1 JUNE 18, 2020
Zibi Ontario BLOCK 206
CHAUDIERE PRIVATE WEST OTTAWA, ONTARIO
DETAILS
Scale 1:10
STAINLESS STEEL HANDRAIL
01
316 SAE, MARINE GRADE STAINLESS STEEL HANDRAIL
· 38mm OUTSIDE DIA.
· BRUSHED FINISH
SQUARE / FLAT ENDS (TYP) NOTES:
1. GRIND SMOOTH ALL EDGES AND JOINTS 2. CONTRACTOR TO SUBMIT SHOP
DRAWINGS FOR APPROVAL PRIOR TO FABRICATION INCLUDING BUT NOT
LIMITED TO EXPANSION JOINT LOCATIONS, FINISH, ANCHORING ETC.
3. CONTRACTOR TO CONFIRM ALL MEASUREMENTS ON SITE PRIOR TO FABRICATION
4. NUMBER OF STAIRS VARIES, REFER TO LAYOUT AND GRADING
4.1. ENSURE COORDINATION WITH CIVIL
920 TOP OF RAIL
R50
152
CAST IN PLACE CONCRETE STAIRS
SECURE POSTS WITH NON-SHRINK GROUT IN CORED HOLE(TYP) 122
350
462 605
R50
122
137 100 TYP
370
GRANULAR 'A' COMPACTED TO 98% SPD
COMPACTED FILL OR UNDISTURBED SUBGRADE AS APPROVED BY GEOTECHNICAL ENGINEER
Scale 1:10
CAST IN PLACE CONCRETE STAIRS
02
170 170 UNIT PAVING
15M NOSING BAR, MIN 70mm COVER
CONTINUOUS 15M REBAR 300mm O.C EACH WAY
▪ ALL STEEL TO BE EPOXY COATED
▪ MAINTAIN MIN 70mm COVER 300TYP
177
R20
STAINLESS STEEL HANDRAIL
GRANULAR 'A' COMPACTED TO 98% SPD
COMPACTED FILL OR UNDISTURBED SUBGRADE AS APPROVED BY GEOTECHNICAL ENGINEER
NOTES:
1. NUMBER OF STAIRS VARIES, REFER TO LAYOUT AND GRADING
1.1. ENSURE COORDINATION WITH CIVIL 2. CARBORUNDUM SAFETY STRIPS REQUIRED,
REFER TO ENLARGEMENT
AS NOTED
319 McRae Avenue, Suite 502, Ottawa, Ontario, K1Z 0B9 Tel: (613) 729-4536
No. Revision Date
Project:
Drawing:
Scale:
Design By: Drawn By:
Date:
Stamp:
North:
Landscape Architecture Urban Design
Site Planning
Recreation and Park Planning Project Management
1. All measurements in millimeters unless specified otherwise.
Do not scale drawing. All drawings to be read in conjunction with written specifications.
2. Copyright reserved. This drawing is the exclusive property of CSW Landscape Architects Ltd. and shall not be used without the consent thereof.
3. This Drawing may not be used for construction until signed by the landscape architect. It is the responsibility of the contractor to:
·check and verify all dimensions on site;
·report all errors and/or omissions to the landscape architect;
·comply with all pertinent codes and by-laws;
·check and verify locations of all underground services with all local utilities prior to any digging.
ISSUED FOR SITE PLAN APPROVAL
1 JUNE 18, 2020
Zibi Ontario BLOCK 206
CHAUDIERE PRIVATE WEST OTTAWA, ONTARIO