SL42:
Smart
lighting
controllers
–
installation
in
the
pole
SL42
controllers
can
drive
electronic
ballasts
(DALI
or
1
‐
10V),
magnetic
ballasts
in
ON/OFF
or
in
dimming.
Based
on
LonWorks®
protocol,
open
and
interoperable
(open
system),
they
can
operate
in
autonomous
mode
or
integrated
into
a
remote
management
system
to
the
lighting
point.
O
PERATING PRINCIPLE1) SL42 smart lighting controller
¾ Communicates on LON® network (LON node ®)
¾ Allows control of ballasts into the pole (dimming and failure detection)
¾ Works independently or integrated into a remote management system
SL42 Lighting controller – Citylone, 19 Route du Pont d’Arthaud 69510 MESSIMY‐ FRANCE, www.citylone.com 2/7
DT_SL42‐xx V1.0 11/04/2012
¾ Communicates with all LonWorks®nodes on power line, two‐way (up to 150 nodes per
segment controller).
¾ Saves data
¾ Sends data to the monitoring software
¾ Operates independently (includes a hourly command an astronomical clock) or controlled by
an external supervision software, via a GPRS / ADSL / Wifi / Radio connection (failure
management, history…).
3) Remote management software
¾ allows to configure and commission network
¾ collects, aggregates and manage data without human intervention from hundreds of segment
controllers
¾ gives access to all web driving applications (detection and failure analysis, historiated curves,
alarms management, "real time" analysis of energy consumption...)
M
EDIA AND COMMUNICATION NETWORK
¾ LonTalk® protocol.
¾ Communication in open and interoperable LonWorks® network (ISO/IEC 14908).
¾ Media : PLC, Powerline : to transmit information via existing electrical network without additional
wiring. (most suitable solution so that all equipment, even from different manufacturers, can
communicate together through electrical network).
¾ Protocol developed by Echelon : optimization of communication paths on the CPL media. Warranty of
constant communication between segment controller (Echelon i.LON) and Citylone lighting
controllers.
SL42
DESCRIPTION¾ Functions :
• Drives and controls any type of ballast (DALI, 0‐10V, magnetic): ignition, extinction, dimming
(to adjust light levels as needed, depending on time schedule)
• Allows control at lighting point or control of a group of lighting points.
• Gets the operating status of each lamp / ballast (instantaneous measurement of voltage,
current, power factor , power consumption) and sends alarm in case of failure
¾ Advantages :
‐ Dimming version on magnetic ballast : patented system
‐ Positive security : lighting on ensured in case of no communication at powering ‐ Configuration of node according to type of lamp and ballast
‐ Control of luminary dimming by percentage from 0 to 100 %
‐ Dimming orders are applied gradually according a configurable slope (except 0% and 100 %
orders which give respectively ignition or extinction of luminary with no wait) => magnetic
version
‐ Instantaneous measurement of voltage, current, power factor and power consumption
‐ Calculation and recording of power consumption and time of ignition
R
ANGE DESCRIPTION
SL42 Lighting controller – Citylone, 19 Route du Pont d’Arthaud 69510 MESSIMY‐ FRANCE, www.citylone.com 4/7
DT_SL42‐xx V1.0 11/04/2012
SL42‐2T
1 monitored output (U, I, power factor) ON/OFF for magnetic or electronic ballast
(3A Max)
1 ON/OFF auxiliary output (3A Max‐500W)
SL42‐FD‐1T*
1 monitored output (U, I, power factor) dimming for magnetic ballasts (250W maxi) 1 ON/OFF auxiliary output (3A Max‐500W)
SL42‐ED‐1T
1 monitored output (U, I, power factor) dimming for electronic 1‐10V ballasts (3A
Max)
1 ON/OFF auxiliary output (3A Max‐500W)
SL42‐EDA‐1T**
1 monitored output (U, I, power factor)
1 dimming output for 2 DALI ballasts (3A Max)
1 ON/OFF auxiliary output (3A Max‐500W)
SL42‐EDA
1 monitored output (U, I, power factor)
1 dimming output for 2 DALI ballasts (3A Max)
‐C Option : measure on auxiliary output
* for magnetic version : capacitor must be upstream the ballast
** ballast must be addressed (address 1 or 2 by default) in order to be able to ask and send back its
status – one controller can control 2 DALI ballasts
SL42 Lighting controller – Citylone, 19 Route du Pont d’Arthaud 69510 MESSIMY‐ FRANCE, www.citylone.com 6/7
DT_SL42‐xx V1.0 11/04/2012
MECHANICAL SPECIFICATIONS
MATERIAL ABS V0 / PMMA
COLOR Charcoal grey
MECHANICAL PROTECTION IP42 DIMENSIONS 337.2 x 75 x 48.4 mm WEIGHT 540 gr ELECTRICAL SPECIFICATIONS POWERING 230 VAC +10%‐15% / 50 à 60 Hz OUTPUT 3A Max FEEDBACKS MEASURES ON AUXILIARY (OPTION ‐C) U, I Power factor Failures Ignition time Energy consumption I on auxiliary Failures on auxiliary CPL SPECIFICATIONS COMMUNICATION CPL(PL3120)
CENELEC EN50065‐1 (4800 bauds)
PROPAGATION Ability to repeat the signal from pole to pole Management of loss of signal
CONNECTION Possibility to connect via internet at the
segment controller (i.Lon Echelon)
LON® NETWORK ISO/IEC 14908
LON® node based on LonTalk® Protocol
CONNECTIONS AND INSTALLATION
CONNECTORS 9 pins unpluggable (5.08mm max) – version
SL42‐FD‐1T
7 pins unpluggable (5.08mm max) – versions SL42‐ED‐1T, SL42‐2T and SL42‐ EDA‐1T
+ 2 pins unpluggable (5.08mm max) – versions SL42‐ED‐1T and SL42‐EDA‐1T
Cables of section0.2 to 3mm² max single stranded, 2.5mm² multi stranded
INSTALLATION In the luminary pole
Fixation by 1 ou 2 screw (not included) or placed with provided side bracked ENVIRONMENT STORAGE TEMPERATURE ‐25°C to + 75 °C USE TEMPERATURE ‐25°C to + 60 °C HUMIDITY 95 % STANDARDSS
DIRECTIVE 2006/95/EC «LOW TENSION »
DIRECTIVE 2004/108/EC « ELECTROMAGNETIC COMPATIBILITY»
DIRECTIVE 2002/95/EC « ROHS DIRECTIVE»
WARRANTY
5 YEARS WARRANTY (SEE GTS FOR CONDITIONS)
A
CCESSORIESTL‐CS iLon Segment controller Single‐phase segment controller, preconfigured with the lighting
application and the remote management software Streetlight.Vision to
configure and manage the controller. TL‐M‐GPRS GPRS modem pack (Modem+power+antenna).
Connection with Ilon via RS232. Automatic configuration Via Ilon
(Modem approved by Echelon)
TL‐C Tree‐phase electricity meter supervised
Electricity meter (Class 1) connected and supervised via a Modbus link
with segment controller (TL‐CS). Measure current, voltage, power,
power factor. Meter comes with 3 toroids (50A) for measurement of
intensity on the 3 phases.
SL‐TP Remote controller Remote controller for Citylone controllers configuration and adressing
(consult us for more information)