Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009Order No. ? and country if required
see below
Hardware &
software Hardware All OpenCom 100
(except OC105/110/120)
Firmware/?
release: 8.513/1.315.14.3 Drivers and
applications see below Contact Jan-Tilo Kirchhoff
Technical Release (release notes) OpenCom 100 Bug-Fix Release 8.513 Contents
Technical Release (release notes) OpenCom 100 Bug-Fix Release 8.513 ... 1
Contents... 1
Change History ... 1
1 Hardware and Software Information... 2
1.1 Hardware... 2
1.2 Software ... 3
1.2.1 Software index / software compatibility... 3
1.2.2 New or modified features... 4
1.2.3 Corrections... 5
1.2.4 Software availability... 11
2 Known Restrictions ... 11
3 Additional Hardware & Software Information ... 11
3.1 Documentation ... 11
3.2 Planning instructions... 11
3.3 Installed base... 11
Change History
Issue Date Name Change
0.1 15.07.09 Helmut Härtel Document created - DRAFT 1.0 15.07.09 Helmut Härtel Release and publication 1.1 20.07.2009 Michael Köhler SW compatibility changes
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/20091 Hardware and Software Information
1.1 Hardware
» No changes were made to the hardware.
» As a result of changes to the system software a memory card is required in the system as of Release 8.50 to operate IP terminals. Details on compatible memory cards can be found in a separate Technical Information.
Material No. Designation Hardware Rev. Firmware Remarks
OpenCom 107 All All Export only
70158 OpenCom 130 All 5.22 (1.170.19)
69698 OpenCom 131 All 5.22 (1.170.19)
70046 OpenCom 150 All 5.22 (1.170.19)
70045 OpenCom 150rack All 5.22 (1.170.19)
69809 OpenCom 510 All All
69287 OpenCom X320 All All
69285 OpenCom X320rack All All
See price list M100-xxx/M300-xxx All All
See price list RFP 21/22/23/24 All -
See price list RFP 31/32 All -
See price list RFP 41/42 All -
n.a. OpenPhone 19 All -
n.a. OpenPhone 19plus All -
70543 OpenPhone 52 All -
See price list OpenPhone 6x All -
See price list OpenPhone 7x All -
See price list OpenPhone 6x IP All -
See price list OpenPhone 7x IP All -
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009Material No. Designation Hardware Rev. Firmware Remarks
69858 OpenPhone 24 All 11.01.07
n.a. OpenPhone 25 All x-2-29
69922 OpenPhone 26 All 018-010-003
69902 OpenPhone 27 All x-1-35
69556 OpenPhone 28 All 68-2-15
68742 Aastra 142d All 91.24.36
1.2 Software
1.2.1 Software index / software compatibility
Component Module Release (Rev.) Remarks
System firmware 8.513 (1.315.14.3) ...
OpenPhone 6x 8.3
OpenPhone 7x 3.80
RFP 21/23 6.10
RFP 22/23 2.06
FW add-ons fwaddons_1_010_9.cnt
FW OP63 IP 3.10.20 OC130/131/150 only
FW OP65 IP 3.05.28 OC130/131/150 only
FW OP7x IP 2.09 OC130/131/150 only
FW DECToverIP 1.0.15 OC130/150 only
FW M100- IP Mgw_1035__1035_10.tar.g
z
OC130/150 only
FW OP7x IP 2.09
IPPhone Configurator 2.0.10
FW DECToverIP 1.0.15
OM Configurator 1.6.2
OpenPhone IPC IPCsetup_1_0_0_75.exe Supports Windows VISTA
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009Component Module Release (Rev.) Remarks
TAPI 3.15 Supports Windows Vista
TCI.DLL 3.15.17 (build 1.315.17)
OC100SP.TSP 3.15 (build 1.315.15)
CAPI 1.21 Supports Windows Vista
TCI.DLL 3.15.17 (1.315.17)
CAPI2032.DLL 1.0.6.1162 (1.65)
CAPI20.SYS 2.20.1.2315
CAPICTRL.EXE 2.20.1.2206
DETEWECP.SYS 1.02 (1.0.4.2)
ULISA.DLL 2.20.1.1005
OpenStartCenter 1.01 Framework for Offline Configurator
OpenCTI Browser 1.3.11 Stand-alone browser for OpenCTI
50
OpenHotel Browser 1.06 Stand-alone browser for OpenHotel
KDA Manager 1.14 Audio conversion tool
OpenCom Systray 3.0 Status display
TCI.DLL >= 3.0 (build 1.315.14)
1.2.2 New or modified features
Change request or serial number
Description
-
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/20091.2.3 Corrections
No. Change
Telephony
1 No handover of call when transferring via QSIG ISDN
When a Notification Indicator of a NOTIFY-Message for a transfer contains
proprietary information (e.g. from an Alcatel system) this message will no more be rejected (STATUS-Message) but will be ignored.
2 Keypad dial to a trunk line does not work
For a user with a special call number list activated, it was no longer possible to perform a keypad dial to a trunk line (code *12). An immediate clear down was performed instead of the trunk line being occupied.
This fault has been remedied.
3 OpenCom X320: Trunk lines sporadically do not go on line
After a reset of the system software after 49 days, see chapter „Miscellaneous“, some trunk lines did not go on line randomly. This fault has been remedied.
4 OpenCom130/150, OpenCom X320: Sporadically no HDLC-Transmission at S0
When layer 1 of an ISDN S0-trunk line is asynchronous for short-time, it could happen that layer 1 and 2 will be active again afterwards but no HDLC-transmission is
possible until the respective line has been pulled out and plugged in again. This fault has been remedied.
5 OpenCom 510: Jammed MGW-Resources
When a MGW -Resource is jammed on FAST_CONNECT, it will be released and FAST_CONNECT is retried. So no more shortage of resources and disturbances will occur.
6 Support of 2-wire door phone from Arzberger (TFE5) .
7 Trunk line prefix for Italy
In Italy up to now ´for national trunk line prefix digits ´0´or ´7´have been accepted.
This led to a problem with a customer. Because noone can tell whether this special treatment is still necessary, it has been removed for testing purposes. This has no impact to other countries.
8 Dropping of callers in hold
When dropping of incoming calls to the operator is configured then also callers in hold will be dropped. Now the connection will remain in hold for a maximum of 3 minutes (2 minutes in Germany), before it will be signalled as a call back (also acoustically) once again.
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009No. Change
9 QSIG-IP: DTMF-String was too long with a random character This fault has been remedied..
10 Hotel: Communication interruption with receptions phone
When the receptions phones has programmed keys for teams or busy keys for room phones, this could led to communication interruption with the receptions phone in case the room phone is checked in or out. This fault has been remedied.
11 Sporadical reset after call pick-up
When several devices have been called in parallel a reset could happen in case of heavy traffic to the system after one of the called devices had picked-up the call. This fault has been remedied.
12 Reset after charge request
With a Q.SIG-connection to a Siemens Hicom system a reset it came to a reset after the Hicom system has sent a charge request. This fault has been remedied.
13 OpenCom X320: MGW-card loses IP-address with an IP-address conflict The MGW-card does not get a new IP-address with a statical MGW -IP-address. The card has to be restarted via the configurator. Now the MGW -card is restarted
automatically in case of loss of the IP-address and gets a new IP-address – this can last until the IP-address conflict has been resolved.
SIP
14 Unilateral connections with outgoing calls from Snom SIP-phones This fault has been remedied.
15 With outgoing calls from SIP internal sporadical resets could happen during authentication
This fault has been remedied.
16 Reset during SIP Client registration of an Asterisk
Prior to registration the Asterisk sends an OPTIONS-message without an username in the request-line, that is without addressing a distinct user. This led to a reset. This fault has been remedied.
17 SIP-authentication occasionally faulty
Some SIP devices cannot be authenticated right at registration or with outgoing calls because they are transmitting an username in the form of user@host with the
authentication header whilst the system is only expecting „user“. Now both variants are accepted.
Database/Service
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009No. Change
18 When deleting a port or registering a Hot-Desking-subscriber a reset could happen
This fault has been remedied.
19 Default configuration:
List of holidays for Germany and Belgium has been updated (2009 - 2011).
20 Configurator / OpenCom X320: Faulty display after expiration of demo license
„Hotel“
A link to the homepage will not be offered any more.
21 Configurator: For Email-accounts no special character in password possible This fault has been remedied.
22 Configurator / OpenHotel: Head of invoice
The head of an invoice will not appear in the configuration menu any more.
23 Configurator: System reset when clicking to call distribution „outgoing PTP“
This fault has been remedied.
24 Sporadical reset in case of overrunning caller list and display at system phone A caller list management error led to an infinite loop. This fault has been remedied.
25 Configurator: Reset by configurator and automatic switch of time group When clicking to an user in the menu \User Manager\User and automatic switch of time group has been activated, this led to a reset. This fault has been remedied.
26 Configurator: Data backup or Errlog did not work,
when a space is in the company name. Now the underline within the filename is inserted again.
27 Configurator: Translation of text strings to portuguese
System phones
28 Change of text for Portugal.
„Internal dialling“ and „External dialling“ have been replaced by „Dialling“.
29 Displaymessages in release message RELEASE will be displayed for 3 s after hang up.
30 Displaymessages in state „Overlap-Sending“ (during dialling) will now be suppressed.
31 OpenPhone 7x IP Application Software Release 2.0.6 incl. Booter Version 1.5.5
32 New terminal-software for OP7x, Version 3.80
Ringing within DHSG-Headset after connection setup cleared.
33 OpenPhone 7x IP Application Software Release 2.0.8
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009No. Change
34 OpenPhone 7x IP Application Software Release 2.0.9
Pickup via XML-key from 6757i led to a disturbed audio channel at OP7xIP. When using G729A(B) the DSP of OP7xIP may not contain any Comfort Noise Packages.
This is assured with SW 2.0.9.
35 Device is frozen after repeated use of headset-key
When the headset-key is pressed twice during an active menu and the headset is deactivated then the device is shut down and must be pulled out and plugged in again. This fault has been remedied.
36 OpenPhone 63/73: IVM -Signalling in Info-line does not work
The existence of a voice message friom an external voice box is not displayed in the info-line by „IVM“ when display of date is activated at OpenPhone 63/OpenPhone 73.
This fault has been remedied.
37 Labelling of a key in spite of error
Although there is an error when programming a function- or destination-key (e.g.
maximum number of keys is achieved) the labelling of the key takes place. This fault has been remedied.
38 Stacking key with functionality „Call Forwarding“ faulty
The feature call forwarding within a stacking key does not work when the feature is programmed with a labelling of its own. This fault has been remedied.
39 Function key „Bundle Sstate“ does not work when the key is programmed with the bundle number as linking key
In this case on key 9 the bundle state for bundle number 4 was programmed. If now key 4 is programmed with a linking key at the device the bundle state key will not work any more. This fault has been remedied.
40 On a function key „Call Forwarding For ...“ without a destination number the number that has to beforwarded will be forced as default destination number when operating
Now an empty destination number is predetermined.
41 Change of melody for pick-up-group-notification-call faulty
When the melody for the pick-up-group-notification-call on a system phone is changed from 10 (default) to 9, then this notification-call can be heard only with the first call to another member in this pick-up-group. Starting with the second call to this member of the pick-up-group the pick-up-notification-call cannot be heard any more but only the optical notification to the display can be seen. This fault has been remedied.
42 Terminals do not stop ringing together with a hunt group (parallel) and team- keys
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009No. Change
Openphone 2x IVM / IAB / AAS
43 ModularXT / AAS: Playback of longer audio files does not work
At playback of longer audio files an interruption occurred. This fault has been remedied.
44 IVM: Expansion with portuguese language
45 AAS: Reset after dialling a DTMF-character
during a connection to the AAS in absence of a menu. This fault has been remedied.
DECT
46 New Software for RFP22
Improvement of the tolerance of the receiver against small time discrepancies of the received signal. Especially for handover (within a receiver) the system performance was improved.
47 New Software for IP-RFPs
Improvement of the tolerance of the receiver against small time discrepancies of the received signal. Especially for handover (within a receiver) the system performance was improved.
Network
48 DHCP-Server: Initialisation error
Multiple start of DHCP-process will be avoided, this could lead to a reset. Statical client entries could loose their statical allocation and could turn to dynamical entries.
This fault has been remedied.
49 OpenCom 130/150, OpenCom 510: Reset after Ping Request The reason was a breakdown in NAT (ICMP packages).
This fault has been remedied.
50 TAPI: Breakdown of Lines
Timeout for user registration increased, error with call forwarding (OpenCom X320 only) corrected.
51 CSTA: When selecting a line sometimes team keys have been selected This fault has been remedied.
Miscellaneous
52 OpenCom X320: Breakdown after 49 days and 17 hours
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/2009No. Change
53 OpenCom X320 / FAX -card: When deleting a user from a fax-group the corresponding fax list entries for this user have not been deleted completely So pretended faxes could exist which could not be accessed. This fault has been remedied.
54 OpenCom X320: System reset with MOH longer than 60s
For MOH-files with a size of n*4096 Bytes in a Linux-file system access beyond memory limits could happen. This fault has been remedied.
55 TAPI / New TSP: Breakdown of Lines
Needless blocking of a line after multiple unsuccessful registration tries has been abolished.
56 Non function of V.24 call data interface This fault has been remedied.
Technical Information OpenCom 100
No.: 003-2009
Situation: 07/20091.2.4 Software availability
» Firmware Release 8,513 (Rev. 1.315.14.3) is available on the Extranet as of dd.mm.2009.
2 Known Restrictions
No known uncorrected restrictions!
3 Additional Hardware & Software Information
3.1 Documentation
» The sales release for Release 8.5 was given on 05.06.2007. This and other topical information can be found at www.aastra-detewe.de
3.2 Planning instructions
» None
3.3 Installed base
» The software is compatible with all current OpenCom 100 platforms. OpenCom 105, OpenCom 110 and OpenCom 120 are not supported.