THE NATIONAL

THE NATIONAL

BUILDING CODE

BUILDING CODE

(CONDO)

(CONDO)

DE GUZMAN, SUSHMITA SEN C. DE GUZMAN, SUSHMITA SEN C.

GUERRIN, GLADYS ANNE GUERRIN, GLADYS ANNE MEJIA, ELAND JETHRO MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P. PUZON, DANE STEFI MARIE P.

SANTOS, KITT SANTOS, KITT

TEMPLO, CHARMAINE Y. TEMPLO, CHARMAINE Y.

(2)
(3)

CLASSIFICATION AND GENERAL

CLASSIFICATION AND GENERAL

REQUIREMENTS OF ALL BUILDINGS

REQUIREMENTS OF ALL BUILDINGS

BY USE OR OCCUPANCY

BY USE OR OCCUPANCY

USE OR OCCUPANCY

USE OR OCCUPANCY UNIT AREA PER OCCUPANTUNIT AREA PER OCCUPANT (Sq. m.)

(Sq. m.)

Minimum of Two Exits other Minimum of Two Exits other than elevators are required than elevators are required where number of occupant is where number of occupant is

over over A. Dwellings A. Dwellings 28 28 1010 B. Hotels B. Hotels 18.6 18.6 1010 Apartments Apartments 18.6 18.6 1010 Dormitories Dormitories 18.6 18.6 1010

(4)

GROUP A GROUP A RESIDENTIAL RESIDENTIAL DWELLINGS DWELLINGS GROUP B GROUP B RESIDENTIAL RESIDENTIAL , HOTEL, AND , HOTEL, AND  APARTMENTS  APARTMENTS

OCCUPANCY TYPE

OCCUPANCY TYPE

• •

Section 701

Section 701

• •

 Section 702

 Section 702

No change shall be made in the character of occupancy of any

No change shall be made in the character of occupancy of any

 building.

 building.

 Section 703

 Section 703

One-storey building with more than one occupancy each portion

One-storey building with more than one occupancy each portion

shall

(5)

TYPES OF OCCUPANCY

TYPES OF OCCUPANCY

SEPARATION

SEPARATION

1.) One

1.) One

––

 Hour Fire Resistive

 Hour Fire Resistive

Operation

Operation

2.) Two

2.) Two

––

 Hour Fire resistive

 Hour Fire resistive

Operation

Operation

3.) Three

3.) Three

––

 Hour Fire Resistive

 Hour Fire Resistive

Operation

Operation

4.) Four

4.) Four

––

 Hour Fire Resistive

 Hour Fire Resistive

Operation

Operation

(6)

LOCATION ON PROPERTY

LOCATION ON PROPERTY

No buildings shall be constructed unless it adjoins a street

No buildings shall be constructed unless it adjoins a street

(7)
(8)
(9)
(10)

MAXIMUM HEIGHT OF

BUILDINGS

(11)

MAXIMUM HEIGHT OF

BUILDINGS

(12)

MEASUREMENT AND

PERCENTAGE OF SITE

OCCUPANCY

(13)

MEASUREMENT AND

PERCENTAGE OF SITE

OCCUPANCY

(14)

MEASUREMENT AND

PERCENTAGE OF SITE

OCCUPANCY

(15)

SETBACK REQUIREMENT

YARD

Type of Residential Use / Occupancy R - 1 (meters) R - 2 R - 3 R - 4 (individual lot / unit meters) R - 5 (meters) Basic (meters) Maximum (meters) Basic (meters) Maximum (meters) Front 4.50 3.00 8.00* 3.00 8.00* 4.50 6.00 Side 2.00 2.00** 2.00** *** 2.00 (optional) 2.00 (optional) 3.00 Rear 2.00 2.00 2.00 *** 2.00 2.00 3.00

(16)

PARKING REQUIREMENT

(17)
(18)

PARKING REQUIREMENT

3.70 M 1.20 M

(19)

ELEVATOR

10.1 ACCESSIBLE ELEVATOR

SHOULD BE LOCATED NOT MORE THAN 30.00 M FROM THE

ENTRANCEAND SHOULD BE

EASY TO LOCATE WITH THE AID OF SIGNS

10.2 ACCESSIBLE ELEVATORS SHALL HAVE A MINIMUM

(20)

CEILING HEIGHTS

Min. 2.40 m

Min. 2.70m Min. 2.40 m Min. 2.10 m

(21)

CEILING HEIGHTS

MEZZANINE FLOORS

Min. 2.70 m

Stairways 1

Min. 1.80 m.

1

st

 Floor w/ Natural

 Ventilation

(22)

SIZE AND DIMENSIONS

OF ROOMS

Min. Area = 1.20 sq. m

(23)

PWD BATHROOM

(24)
(25)

 WINDOW OPENING

(26)

 ARCADE

 ARCADE    M    I    N .    3 .    0    0    M

(27)

BUILDING PROJECTION

OVER PUBLIC STREETS

(28)

CORRIDORS

3.4 A MINIMUM CLEAR LEVEL SPACE OF 1.50 M X 1.50 M

SHALL BE PROVIDED BEFORE EXTENDING BEYOND A DOOR; EXCEPTION: WHERE A DOOR SHALL OPEN ONTO BUT NOT INTO A CORRIDOR, THE

REQUIRED CLEAR, LEVEL SPACE ON THE CORRIDOR SIDE OF THE DOOR MAY BE A MINIMUM OF 1.20M

CORRIDOR WIDTH

3.5) PROTECTION SHOULD BE PROVIDED FROM DOORS THAT SWING INTO CORRIDORS

(29)

RAMPS

(30)

STAIRWAYS

 A

B

(31)

STAIR LANDING

Max. 1.20 m max. 3.60 m Min. 2.00 m

(32)

HAND RAIL

0.80 m < x > 0.90 m 3 m

(33)

EXITS

EXIT 1

Occupant load of more than 10

EXIT 2

OCCUPANT LOAD NO. OF EXITS  Above first storey

More than 10

2 500-999 3 1000 or more 4

(34)

500  999 Occupant Load Exit 1 Exit 2 EXIT EXIT < 1/5

EXIT DISTANCES

(35)
(36)

MIN OF 1.10 M

(37)

Hazardous Areas/ 50 or more load    M    I    N    O    F    2    M

DOOR EXIT

(38)

NATIONAL BUILDING CODE

OF THE PHILIPPINES

(Mall)

DE GUZMAN, SUSHMITA SEN C. GUERRIN, GLADYS ANNE

MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P.

SANTOS, KEITH L. TEMPLO, CHARMAINE Y.

(39)

Building Occupancy

Group E:

(40)
(41)

PARKING REQUIREMENTS

Building Type Number of parking slot Markets 1 slot/150 sq.m. of shopping floor

area Restaurants, Fast-food centers,

 bars and beerhouses 1 slot/30 sq.m. of customer area Office buildings 1 slot/125 sq.m. of gross floor area Other buildings in business/

commercial zones 1 slot/125 sq.m. of gross floor area Public assembly buildings

(theaters, cinemas, auditorium, stadium, etc.)

1 slot/50 sq.m. of spectators area Building Type (Recreational

Facilities)

Number of parking slot Bowling Alleys 1 slot/4 alleys

(42)

PARALLEL PARKING

2.00m  6.00m  5.00m  2.40m 

PERPENDICULAR PARKING

(43)

Truck and Bus

3.60m  12.00m  2.40m  5.00m 

Diagonal Parking

(44)

PARKING FOR PWD

 1 accessible parking slot for the handicapped per 50 parking lots up to 150

slots and an additional slot for every 100 slots

 Maximum distance of accessible parking area from facility served. Parking

areas for the physically handicapped shall be within 60.00m of the facility  being served. FACILITY SERVED  WALKWAY PARKING SLOT PARKING SLOT PARKING SLOT PARKING SLOT PARKING SLOT

(45)

90 DEG. PARKING BAY ONE SIDE 13.50m  3.00m  7.20m  ONE WAY TWO WAY 5.70m  2.55m to 2.70m 

(46)

90 DEG. PARKING BAY TWO SIDES

3.00m  7.20m  ONE WAY TWO WAY 5.70m  2.55m to 2.70m  19.00m to 19.50m

(47)

D A B C X Y Z 90 18.60 5.70 7.20 18.60 5.70 7.20 60 18.00 6.30 5.40 16.65 5.65 5.40

(48)

R = 17.00m to 21.00m  4.00m to 4.50m  4.00m to 4.50m  DN UP

(49)

Bus

Planning and Designers Handbook (Second Edition) 7.60m 

3.00m 

17.60m 

2.70m  2.10m 

(50)

Section 1207. Stairs, Exits, and Occupant Loads

C

 1: Exit Door shall swing in the direction of travel.

Double Acting Doors shall not be used as exits.

(51)

Section 1207. Stairs, Exits, and Occupant

Loads

C-3: Exit doorway shall be of a size as to permit the

installation of a door not less than 900mm and not less

than 2.00m in height

(52)

Section 1207. Stairs, Exits, and Occupant

Loads

C-5: Revolving, sliding, and overhead doors shall

not be used as required exits.

(53)

Section 1207. Stairs, Exits, and Occupant

Loads

D-1: Every corridor or exit balcony shall not be

less than 1.10 meters in width

(54)

Section 1207. Stairs, Exits, and Occupant

Loads

D-3: When more than one exit is required, they shall

 be arranged to allow going to either direction from

any point in the corridor.

(55)

Section 1207. Stairs, Exits, and Occupant

Loads

Corridors and exterior exit balconies with dead ends

are permitted when the dead end does not exceed

6.00 meters in length

(56)

Section 1207. Stairs, Exits, and Occupant

Loads

E-1: Stairway widths

Occupant Load (X) = Minimum Width

X > 50

= 1100MM

X < 50

= 900MM

X < 10

= 750MM

Trim and handrails shall not reduce the required width by

more than 100MM

(57)

Section 1207. Stairs, Exits, and Occupant

Loads

E-3: Winding stairways may be used if the required

 width of the run is provided at a point not more than

300MM from the side where the treads are

narrower.

(58)

Section 1207. Stairs, Exits, and Occupant

Loads

E-5: Every landing shall be a dimension measured in the

direction of travel equal to the width of the stairway.

Such dimension need not exceed 1.20m when the stairs

has a straight run.

(59)

References

Related documents

(a) For axially loaded compression members and flexural members whose proportions are such that the quantity ( ρ) for load capacity is unity, as determined in accordance with

Street light plans shall be submitted and approved as to the location, height and wattage to the City Engineer (if applicable) prior to issuance of any building permits or

The SRS document aims to explain in an easy manner, the basic idea behind Android based chat messenger and how the developers aim to achieve their goals.. It also aims to

Established in 1985, Bharti has been a pioneering force in the telecom sector with many firsts and innovations to its credit, ranging from being the first mobile service in Delhi,

In NC milling, as the tool moves along the tool path, it is in contact with the workpiece over a common surface called the cutter workpiece engagement (CWE) surface.. One of

RiskOTe SDSS fills a gap among the existing tools, based on the following principles: (i) It considers explicitly the risk concept in spatial planning decision-making

The data employed in this study to assess possible harmonization of FAWS at European level were acquired through two different sources: 1) a questionnaire and accompanying

Our 3-D velocity model exhibits high velocities in the depth range of 30-50 km beneath western Arabia, eastern Mediterranean, Central Iranian Block, South