• No results found

Server Technology, Inc.

N/A
N/A
Protected

Academic year: 2021

Share "Server Technology, Inc."

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

The Top 10 things every data

center manager should know

about power

White Paper STI-100-014 2012-April

Server Technology, Inc.

Headquarters

Server Technology, Inc.

1040 Sandhill Drive Reno, NV 89521

United States of America +001 (775) 284 2000 Tel +001 (775) 284 2065 Fax [email protected] www.servertech.com www.servertechblog.com EMEA

Server Technology Intl.

Sienna Court The Broadway Maidenhead Berkshire SL6 1NJ United Kingdom +44 (0) 1628 509053 Tel +44 (0) 1628 509100 Fax APAC

Server Technology, Inc.

37th Floor, Singapore Land Tower

(2)

Overview

The Data Center industry has been a primary focus of energy consumption for many years due to increasing power demands and the need to continuously provision for more power. This need for more power capacity, augmented by the increasing cost for electricity, has created a new found urgency to effectively manage the power resources and energy usage. It is more prevalent than ever before for the Data Center Manager to ascertain the capability to determine, drive and report on energy efficiency while overseeing capacity planning management.

(3)

Power Density and Voltage

With the rack equipment and power density requirements continuously increasing, it is important to choose a power delivery and monitoring solution to maximize energy efficiency. Today more than ever, it is important to do the most you can with what you have. Of course the chosen solution will be restricted to the power delivery options available within the given infrastructure. Following are items to consider that can provide greater efficiency with increased power to the data center IT equipment rack:

1. Deliver 3-Phase power over single-Phase. This will accommodate greater power density over single-phase power and with power monitoring of the phase loading, this will provide less wasted power and the ability to maximize efficiency through better 3-Phase power load balancing.

2. Provide increased voltages to the equipment. Select a power distribution system based on the maximum available power to the supply rated voltages on each device to maximize efficiency. Equipment will operate more efficiently using the highest supported voltage available.

Higher voltage AC power delivery to the rack and IT equipment

There is a push in the North American datacenters for higher voltage power delivery all the way to the rack and ultimately the end IT equipment. Nearly all Information Technology (IT) equipment today is designed with Auto-sensing power supply modules that can operate within a specified AC voltage range. It is common today for a Power Supply (PS) operating range of 100-to-250 Volts AC in order to accommodate worldwide power distribution compatibility.

Some Typical North American Rack Based Power Distribution Options: • 120V 30A, 1-Phase = 2.8 kW (NEC Continuous Current Rating) • 208V, 30A, 1-Phase = 4.9 kW (NEC Continuous Current Rating) • 208V, 30A, 3-Phase = 8.6 kW (NEC Continuous Current Rating) • 208V, 60A, 3-Phase = 17.3 kW (NEC Continuous Current Rating)

• 415V, 30A, 3-Phase = 17.3 kW (NEC Continuous Current Rating) [NOTE: 240 VAC to the IT device]

Historical Baseline:

• North American 120/208V • Japan 100/200V

• 230V for most of the remaining world

Although this is not a new technology, it is only within recent years that the datacenters within North America have begun implementation with a renewed interest in pushing even higher voltages to the end IT equipment within the rack.

The renewed drivers for the adoption of this are resultant from the following: • Increased capacity

o The need to support greater equipment rack densities – reduced space requirements.

• Reduced energy losses will increase efficiency

(4)

from there to the racks, and from within the racks it is typical that power strips will further distribute the power to the IT equipment.

o The IT equipment (servers, storage and network devices) AC Power supplies are able to more efficiently convert the AC power to DC power for the device

components at the higher supported voltages. Typical IT equipment Power Supplies will transform from AC to 3.3, 5, and 12 VDC. These DC voltages are used to operate the device Printed Circuit Board (PCB) components within the IT equipment such as Servers, Storage, and Network devices.

• Decreased infrastructure and equipment expenses o Less breakers at the Remote Power Panel (RPP) o Less cable runs – reduced copper wire requirement

Power &

Environmental Monitoring in the IT equipment Racks

Data centers are now dealing with more & more devices within individual racks. This increased power within the rack, along with higher data center operating temperatures, requires careful consideration to maintain uptime and ensure minimal interruptions in service. A 4% energy savings is realized for each upward degree change in the data center set point. This is driving up the Data Center Operating set temperature upwards to 78 degrees and higher. Increased density along with increased operating set temperatures is one of the catalysts for requiring a rack-level power and environmental monitoring system.

3. A quality rack-level power monitoring solution will enable immediate/automated response in

order to avoid bigger problems affecting additional equipment and applications. Any solution

being considered should allow for: • Management of power remotely • Improved Uptime

• Improved reliability and availability

4. Be sure to evaluate security when considering a monitoring method. If you have multiple locations to monitor, you’ll probably want to evaluate Web-Enabled PDU Management systems that can Consolidate Information across Multiple Locations. As you drill down into the more specific features of a secure monitoring solution, the Best Practices for a rack-based monitoring system should allow for:

• Real-Time Alarm Notification • Centralized SNMP Trap Information • Multiple User Access Levels • Temperature & Humidity Sensing • User Defined Load Shedding • Historical Power Trending • Outlet control capabilities

Power Use & Measuring Energy Efficiency

(5)

Practitioner was introduced to go further than PUE and include measurement for the useful work being performed by the IT equipment. This is not easily measured and still requires a measured PUE. The goal of these metrics is to provide a common standard for comparing power usage within Data Centers, as well as provide a means for measured improvement. Choosing the method to measure your facilities power requires careful analysis.

Having the ability to monitor device-level energy usage, plus the ability to monitor rate of consumption will increase the DC Manager’s insight as to what’s happening within the Data Center and will provide

characterization for changes to enable power efficiency improvements. . A key point to remember is that the application service level usage is what drives DCeP.

With enterprise level monitoring and power control down to the device level, or rack PDU outlet level, this can provide key features that enable capabilities identifying areas for energy efficiency improvements:

5. Power control to the rack PDU’s individual outlets will assist with security, capacity and provide simple savings by scheduling outlets to be turned off when not needed.

• Management can help an administrator protect the enterprise against unauthorized usage by controlling the state of the outlets.

• If a rack PDU is functioning at its rated limits, simply turn off any unused outlets to prevent anyone from powering additional IT equipment and tripping any circuit protection.

• Similar to turning off a light when no one is in the room, if IT equipment is only used for a particular time period, or if workload diminishes at particular times, powering off the gear is the simplest way to conserve energy.

6. Using kWh information with low power threshold triggers can identify underutilized or idle IT equipment for consolidation or virtualization candidacy.

• With the energy usage numbers the following questions can be answered:

What servers are pulling how much power? The energy usage per customer or department can be determined.

7. Cost allocation can be achieved with kWh numbers from a low level to a high level and can be useful for individual department usage or charge back or within a ‘colo’ setting where actual usage can be compared to fee models.

• Why conserve energy if I am not being billed for it?

8. Having the ability to monitor loading at the rack PDU input provides information to prevent overloading the circuit and tripping any Remote Power Panel (RPP) circuit protection.

• With accurate circuit load monitoring and alarming, circuits close to overload can be identified before they become problematic.

9. Outlet level monitoring capability that includes quality of power measurements such as Power Factor and Crest Factor can provide an indication of an IT device power supply failure before complete failure.

• Having the ability to monitor consumption at the IT device will help keep potential problems at bay. 10. You cannot knowingly improve something that is not being measured!

(6)

• Power Reporting and Trending capability in power consumption for devices, applications or departments based upon finite time periods or seasonality.

.

References

Related documents

* This paper is presented to the 2nd KRIS-Brookings Joint Conference on "Security and Diplomatic Cooperation between ROK and US for the Unification of the

Therefore, this study aims to identify the positive and the negative politeness strategies that both genders use in making a rejection and also to compare, to what

Our methodology is based on (1) the identification and description of scientist’s points of view, (2) the construction of a generic conceptual model integrating

n   Payment Card Industry – Data Security Standard 3.0 n   Criminal Justice Information Services (CJIS). n   Internal Revenue Service (IRS) Publication 1075 n

benchmark the Power Usage Effectiveness** (PUE), Data Centre Infrastructure Efficiency** (DCiE) and usage of the server room environment through direct analysis of power and

In addition, the longer course considers the role of the data protection officer in detail, a wider consideration of security and transfer matters in the context of ISO27001

This month our focus is on conserving and increasing vital energy, In the videotaped talk we’ll watch this week, Sri Easwaran says that we can get clues for improving our meditation

1. Scrutiny —implies a lesser intensity and continuity of attention to administrative operations. Its primary purpose is to determine economy and efficiency of the operation of