• No results found

Form release date 2007/01/02

N/A
N/A
Protected

Academic year: 2021

Share "Form release date 2007/01/02"

Copied!
12
0
0

Loading.... (view fulltext now)

Full text

(1)

Form release date 2007/01/02

Model HPC-1420-ISSE & HPC-2820-ISSE

Description BIOS CPU Chipset Memory LAN VGA Storage Front Panel Tested System

3.5-inch hot-swappable SAS/SATA-II HDD bays x4 Slim optical drive x1

USB 2.0 ports x2

Power switch / Reset Switch / Location Switch

LEDs: Power, HDD access, location, message, LAN1, LAN2 / HDD LEDs: Status, activity DSBF-DR12/SAS Server/workstation BIOS Revision 1001

Intel Dual-core Xeon 2.33GHz/8M/1333 x2(E5345) Intel Dual-core Xeon 2.33GHz/4M/1333 x2(5140) Intel Dual-core Xeon 2.00GHz/4M/1333 x2(5130)

North Bridge: Intel 5000P MCH; South Bridge: Intel ESB2E; I/O Bridge: Intel RXH-V

LSI SAS1068 controller

ATI ES1000(RN50)VGA controller 1U Rackmount Barebone Server 2U Rackmount Barebone Server

Transcend 2GB 240P DDR2 667 FB-DIMM x4 (TS256MFB72V6K-T) Transcend 1GB 240P DDR2 667 FB-DIMM x4 (TS128MFB72V6J-T)

(2)

Rear Panel

Power Supply

Hard Disk

Seagate Barracuda 7200.9 80GB SATA x 4 Seagate ST336754SS 36GB SAS x2 Seagate ST373454SS 73GB SAS x2 Seagate ST3146854SS 146GB SAS x2

DC700W Redundant power supply AP15FS22 AcBel

PS/2 keyboard port x1 PS/2 mouse port x1 Serial port x1 VGA port x1 USB 2.0 ports x2

RJ-45 ports (with LEDs) x 2

(3)

Basic Test Result Notes

CPU Coller installation PASS

RAM installation PASS

VGA connector PASS

PS/2 keyboard connector PASS

PS/2 mouse connector PASS PASS PASS PASS PASS

External COM1 PASS

External COM2 PASS

Power Switch PASS

Reset Switch PASS

Location Switch FAIL

Power LED PASS

Location LED FAIL

Message LED PASS

LAN1 LED PASS

LAN2 LED PASS

HDD Access LED PASS

HW Monitor ASR (Automatic System

Restart) PASS

LAN 1 RJ45 connector PASS LAN 1 ACT/LINK LED PASS LAN 1 SPEED LED PASS

LAN 2 RJ45 connector PASS LAN 2 ACT/LINK LED PASS Front panel USB connector

(4)

LAN 2 SPEED LED PASS

Hot-swap hard disk drive 1 PASS

HDD1 status LED 1 PASS

HDD1 status LED 2 PASS

Hot-swap hard disk drive 2 PASS

HDD2 status LED 1 PASS

HDD2 status LED 2 PASS

Hot-swap hard disk drive 3 PASS

HDD3 status LED 1 PASS

HDD3 status LED 2 PASS

Hot-swap hard disk drive 4 PASS

HDD4 status LED 1 PASS

HDD4 status LED 2 PASS

CD Insertion PASS

Flobby Insertion PASS

(5)

Sheet1!A1

SATA RAID O.S. Installation test Result Notes

RAID

RAID 1E

IME (Integrated Mirroring Enhanced) 3 HDD + 1 hot-spare

PASS

O.S. Installation

Windows 2000 + SP4 (32-bit)

limitation

RAID function

Automatically rebuilding PASS

hots-wap PASS

degarded PASS

hots-spare PASS

SATA RAID O.S. Installation test Result Notes

RAID

RAID 1E

IME (Integrated Mirroring Enhanced) 3 HDD + 1 hot-spare

PASS

O.S. Installation

Windows 2003 (64-bit) PASS

RAID function

Automatically rebuilding PASS

hots-wap PASS

(6)

hots-spare PASS

SATA RAID O.S. Installation test Result Notes

RAID

RAID1

IM (Integrated Mirroring) 2 HDD + 1 hot-spare FAIL

O.S. Installation RedHat 9.0 FAIL RAID function Automatically rebuilding NA degarded NA hots-wap NA hots-spare NA

SATA RAID O.S. Installation test Result Notes

RAID

RAID1

IM (Integrated Mirroring) 2 HDD + 1 hot-spare PASS

O.S. Installation

Windows XP (64-bit) PASS

RAID function

Automatically rebuilding PASS

(7)

hots-wap FAIL

hots-spare PASS

SATA RAID O.S. Installation test Result Notes

RAID

RAID1

IS (Integrated Striping) 2 HDD PASS

O.S. Installation

Windows 2003 (64-bit) PASS

RAID function

Automatically rebuilding NA

degarded NA

hots-wap NA

hots-spare NA

SATA RAID O.S. Installation test Result Notes

RAID

RAID 1E

IME (Integrated Mirroring Enhanced) 2HDD PASS

O.S. Installation

Windows XP + SP2 (32-bit)

limitation

RAID function

Automatically rebuilding PASS

(8)

degarded PASS

(9)

Sheet1!A1

SAS RAID O.S. Installation test Result Notes

RAID

RAID 1E

IME (Integrated Mirroring Enhanced) 2HDD PASS

O.S. Installation

Windows XP + SP2 (32-bit)

limitation

RAID function

Automatically rebuilding PASS

hots-wap PASS

degarded PASS

(10)

Sheet1!A1

Driver Installation test (on SATA RAID) Result Notes

O.S. Installation

Windows 2000 + SP4 (32-bit)

limitation

Driver Installation (Rev. 1.0)

CSI Driver PASS

VGA Driver PASS

LAN Driver PASS

LSI SAS Driver PASS

LSI SAS uility PASS

Other

FAIL

Driver Installation test (on SATA RAID) Result Notes

O.S. Installation

Windows 2003 (64-bit) PASS

Driver Installation (Rev. 1.0)

CSI Driver PASS

VGA Driver PASS

LAN Driver PASS

LSI SAS Driver PASS

LSI SAS uility PASS

Other

FAIL

(11)

ASWM PASS

ASUS Network Utility PASS

Asus remote console PASS

Driver Installation test (on SATA RAID) Result Notes

O.S. Installation

RedHat 9.0 FAIL

Driver Installation (Rev. 1.0)

CSI Driver NA

VGA Driver NA

LAN Driver NA

LSI SAS Driver NA

LSI SAS uility NA

Driver Installation test (on SATA RAID) Result Notes

O.S. Installation

Windows XP (64-bit) PASS

Driver Installation (Rev. 1.0)

CSI Driver PASS

VGA Driver PASS

LAN Driver PASS

LSI SAS Driver PASS

(12)

Other

FAIL

Management Software

ASWM PASS

ASUS Network Utility PASS

Asus remote console PASS

Driver Installation test (on SATA & SAS

RAID) Result Notes

O.S. Installation

Windows XP + SP2 (32-bit)

limitation

Driver Installation (Rev. 1.0)

CSI Driver PASS

VGA Driver PASS

LAN Driver PASS

LSI SAS Driver PASS

LSI SAS uility PASS

Other

FAIL

Management Software

ASWM PASS

ASUS Network Utility PASS

References

Related documents

Number range and controlling parameter (settlement rule) are picked during creation of production or process order according to the configuration setting defined in

However, the way Nordan moves Winston between readers’ in and out groups is valuable to understand, especially as he uses Winston in his later work (which even his first readers

PVC-coated, rubber or similar type is recommended for repeated contact with use solution, or direct contact with concentrate.

For this reason, designing clinical decision support systems that collect data from these exergame-based interventions, and using them to monitor the patients, is a very promising

RAID with striping (like RAID 0 and RAID 5) when using on-motherboard SATA

Pollutant: NA Start date: NA Start time: NA Duration in hours: NA Cause: NA EMISSION LOADS. Yearly and monthly emission load in

CITY OF JOPLIN, MO ENGINEERING DIVISION 602 S MAIN ST 64801 DATE: 2/2019 CKD BY: JOHNSON ENGINEER: HERTZBERG FILE: MHABANDN BACKFILL WITH FLOWABLE FILL OR CONCRETE TO GROUND