-Date received: 25-11-10 Date of issue: 14-12-10 Report consists of 2 attached sheets.

Sample name: TEN DRAWER

TEST REPORT N° 123011

List performed tests

1. Strenght of drawer runners ISO 7170:2005 clause 7.5.2 2. Durability of extension elements ISO 7170:2005 clause 7.5.3

FORMENTI & GIOVENZANA S.P.A. VIA PIAVE 55-C.P. 58

20050 VEDUGGIO CON COLZANO (MI) ITALY

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: lab@catas.com Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: lissone@catas.com centro ricerche-sviluppo

laboratorio prove settore legno-arredo

Page 1 of 2

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Defects before testing: None

(4)

Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. centro ricerche-sviluppo

laboratorio prove settore legno-arredo

TEST REPORT

123011 / 2

Date received: 25-11-10 Date of test: 01-12-10 Date of issue: 14-12-10 Sample name: TEN DRAWER

Durability of extension elements ISO 7170:2005 clause 7.5.3

FORMENTI & GIOVENZANA S.P.A. VIA PIAVE 55-C.P. 58

20050 VEDUGGIO CON COLZANO (MI) ITALY Fax 0432.747250 http://www.catas.com e-mail: lab@catas.com Tel. 039.464567 Fax 039.464565 e-mail: lissone@catas.com

Type of runner:

Number of

cycles

metal roller bearing covered by plastic material with closure system

Remarks

Lenght of the drawer travel:

435 mm

Inner usable dimensions:

515 x 430 x 120 mm

Test results :

Load on

drawer

kg

45

80.000

None

Test has been carried out with the load specified by the client

Note: number of cycles as table Tab. 1 of BS 4875-7:2006, level 4°

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

(5)

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. centro ricerche-sviluppo

laboratorio prove settore legno-arredo

TEST REPORT

123011 / 1

Date received: 25-11-10 Date of test: 01-12-10 Date of issue: 14-12-10 Sample name: TEN DRAWER

Strenght of drawer runners ISO 7170:2005 clause 7.5.2

FORMENTI & GIOVENZANA S.P.A. VIA PIAVE 55-C.P. 58

20050 VEDUGGIO CON COLZANO (MI) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: lab@catas.com Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: lissone@catas.com

Type of runner:

Number of

cycles

metal roller bearing covered by plastic material with closure system

Lenght of the drawer travel (L):

435 mm

Inner usable dimensions:

515 x 430 x 120 mm

Vertical

force

N

Remarks

Test results:

450

10

None

Note: vertical force as table Tab. 1 of BS 4875-7:2006, level 5°

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

(6)

Date of issue: 14-12-10

Sample name: TEN DRAWER

TEST REPORT N° 123011

Page 2 of 2

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Drawer closed Drawer opened

Runner on the drawer Sample weight

Overall dimensions

Not determined

600 x 560 x 725 (h) mm (*)

(*) Extended uncertainties of weight and overall dimensions of the sample are 0,1 Kg and 5 mm, respectively

Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. Fax 0432.747250 http://www.catas.com e-mail: lab@catas.com Tel. 039.464567 Fax 039.464565 e-mail: lissone@catas.com centro ricerche-sviluppo

(7)
(8)

References

Related documents

q w e r t y Description Rod cover Head cover Cylinder tube Piston rod Piston Bushing Cushion valve Snap ring Tie rod Tie rod nut Wear rod Rod end nut Back up O ring Rod seal Piston

Electron micrographs of mannonamide aggregates from water (a-e) or xylene (f): (a and b) details of aged fiber aggregates of D-mannonamide 2 negatively stained

The Master Fund is authorised in Luxembourg as a specialised investment fund and is managed by a management company, Ress Capital Fund Management SA, who acts

Using a nationwide database of hospital admissions, we established that diverticulitis patients admitted to hospitals that encounter a low volume of diverticulitis cases have

Legal norms that sanction the implementation of the merit principle in the civil service, predict a special protection for the main personnel of the public

The aim of this paper was to explore the effects on the French forest sector of three policies to mitigate climate change: a fuelwood consumption subsidy (substitution), a payment

The kitchen, the dining room, the hall and even the downstairs bedroom all have French doors that open onto a large patio terrace and then the rest of the garden is laid to lawn..

de Klerk, South Africa’s last leader under the apartheid regime, Mandela found a negotiation partner who shared his vision of a peaceful transition and showed the courage to