ACOME
Complete systems for:
Plumbing systems
Hot and cold water distribution
Principle:
The appliances (plumbing, radiators, fan-coil units, etc.) are
individually supplied
from a
header / distributor.
Direct connection, without discontinuity or couplings,
is done by ducted PEX-c or PB
pipes incorporated into the structures (see diagrams) or by surface-mounted multi-layers.
A complete system – The components:
• PEX-c, PB or multi-layer pipes (with or without ducts) which meet with international
requirements (see page 4, pipes can be supplied by ACOME).
• Complete range of NF or DIN crimped fittings
• Accessories for inlets and outlets in structures
• Header / Distributor
• Valves and accessories
• Manual or battery-operated crimping guns
A large number of advantages:
• Easy installation = less time required
Fewer nuisances = absorption of circulation area noises, decreased heat losses
• Increased safety = elimination of pipework corrosion and furring
Hydraulic and electric
Four comple
Hydraulic under floor heating / cooling
Installed with a concrete slab or a wet screed
Hydraulic under floor heating
Dry solution, installed without any concrete
More than 20 years experience and references:
over 30,000,000 m
2of Acome floors have been laid across the world
Innovation prizes
Nominated at the Paris international Interclima 2004 trade show
Installed within 22 mm!
Re
al thi
22
m
W
ALL / P
ARTITION
Permanent elasticity joint Skirting Peripheral insulation 2 PEX-c pipes PE /aluminium undercoat Floating floor PSE slab with aluminium film
Support
Skirting Floor finishW
ALL / P
ARTITION
Permanent elasticity joint Peripheral insulation PEX-c pipe
Isolation slab on pads
Support
Anti-shrinkage web (if required)
Concrete slab or wet screed
• Thin system:
taking 22 m
• Lightweight system:
very
• System that can be laid o
• Easy system:
very quick i
• Dry system:
premises are
ACOME under floor heating systems are used to provide total or partial heating or heating/coolin
apartment blocks, and in the business sector: offices and factories. They are fully adapted to schoo
stadiums. They can also be used outdoors to prevent the formation of black ice, as solar panels, etc
c under floors heating
ete systems
Electric under floor heating, permanent output cable
Installed with a concrete slab or a wet screed
W
ALL / P
ARTITION
Skirting Permanent elasticity joint
PE /aluminium undercoat Peripheral insulation Self-regulating cable Floating floor
Support
ickness
m
m
Skirting Floor finish Underfloor form (if required)W
ALL / P
A
RTITION
Permanent elasticity joint Peripheral insulation
Permanent output cable on plastic mesh grid
Isolation slab on pads
Support
Anti-shrinkage web (if required)
PSE slab with aluminium film
mm
y little added load
over
existing floor
installation
immediately usable
ng. They can be used to cover all site configurations: new or retrofit works for family homes and
ls, hotels, restaurants and churches as well as sports complexes: gymnasiums, swimming pools and
c.
Concrete slab or wet screed
Electric under floor heating, self-regulating cable
Dry solution, installed without any concrete
A real innovation!
Installed within 22 mm!
Customised systems
The components:
With over 20 years experience and references across the world, ACOME obviously to be your
industrial partner, allowing you to provide your clients with complete solutions, whether for hot
and cold water distribution, radiators and convectors or for hydraulic or electric under floor
heating systems. A few examples:
• The PEX-c pipe
ACOME provides a full range of pipes, from DN 12 to DN 25, either uncovered or ducted.
• PSE pipe-guide slabs
ACOME provides a range of PSE slabs, thickness according to requirements, for floor heating
systems.
• Header/distributor kit
This kit distribution between the generator and the heating unit.
… /…
The components meet the standards and certifications in force in the following
countries:
STANDARD
CERTIFICATION
Germany Netherlands GB USA France Italy BRL 5606 BRL-K536 / 04 KOMO KIWA BS 7291 NF T 54085 Technical assesment CSTBat certificationAttestation of Sanitary Conformity
DIN CERTCO DIN 4726 DIN EN 15875 DIN CERTCO BBA ASTM F876 / F877 NSF 14 NSF ICC
STANDARD
CERTIFICATION
Spain Switzerland Canada Czech Republic Belgium DIN CERTCO CSA DIN CERTCO DIN CERTCO CSA B 137.5 UNE EN 15875 AENOR DIN 4726 DIN EN 15875 DIN 4726 DIN EN 15875 DIN 4726 DIN EN 15875 DIN 4726 DIN EN 15875ACOME worldwide
Industrial facilities – France: Mortain / China: Wuhan and Xintai / Brazil: Irati
Subsidiaries ans offices
Agents and distributors
Three fields of activity, systems dedicated
Building sector
Electrical equipment
Telecommunications
A few references …
•
Castello-Vigevano (Piemonte - Italy)
1•
Versailles Castle (Versailles – France)
•
San Gregorio church (Milan – Italy)
•
TGV Lyon/Satolas (Lyon – France)
2•
British Museum (London – GB)
•
Bercy Exhibition (Paris – France)
•
Institut du Monde Arabe (Paris – France)
•
Notre Dame de Fatima church ( Zapopane – Poland)
•
Benetton factory (Trévise – Italy)
•
Fabriano (Ancona - Italy)
3•
Danone research centre (Palaiseau – France)
•
Castello-Vigevano (Piemonte - Italy)
4•
Skating rink (Courchevel – France)
And a large number of industrial,
residential and apartment block projects.
43 2