Welcome to your handy guide
to ResMed masks
Here you’ll find mask selection information,
fitting guides, product codes, product features
and benefits for the full range of ResMed mask
systems - pillows, nasal, full face, non-vented
and disposable.
Only from ResMed - world leaders in
mask technology.
contents
SELECTING A MASK
NASAL MASKS
FULL FACE MASKS
NASAL PILLOWS
NON-VENTED MASKS
DISPOSABLE MASKS
TECHNICAL SPECIFICATIONS
MASK/DEVICE COMPATIBILITy
SELECTING A MASK
Mask Type
Selection
• Select the appropriate mask type by
following the flow diagram on the right.
• Ideally, the patient should choose their
preferred mask with clinical guidance.
Useful tips
• A full face mask is preferable for
patients with mouth leak.
• If a full face is not required, a nasal
system should be first choice.
• Pillows should be considered as the
nasal mask of choice.
Past nasal / soft palate surgery (e.g. UPPP)? YES
Rhinitus? Sinusitis? Hay Fever? YES No Humidifier
Other nasal symptoms (e.g. Mouth breathes)? YES
Claustrophobic? Skin conditions / allergies? YES
Active sleep? Poor fit in past / present? YES
YES With Humidifier
SwiftTM LT Mirage ActivaTM LT Mirage QuattroTM OR Mirage LibertyTM NO NO NO NO NO
Swift LT OR
Mirage Activa LT OR
Mirage MicroTM
1
2
3
4
5
Mask Size
Selection
• Select the appropriate mask size
by following the instructions.
• The range of sizes ensures that
every patient can achieve optimal fit.
Useful tips
• The 2D sizing templates will help you
determine the optimal cushion size.
• If the template opening is too close to their
nares or nasal perimeter, that size cushion
is incorrect and may cause the patient to
experience discomfort from pressure on
the nasal bridge or cheek bones.
• Incorrect cushion size can also lead to leak
into the eyes or around the nose.
• Place the fitting template around the nose and align
arrow to bottom of the nose.
• Obtain a close fit around the nose allowing some
clearance around the nostrils and the nasal bridge.
Mask Size
Mirage Micro
NASAL MASK
Mirage Activa LT
NASAL MASKUltra Mirage
TMII
NASAL MASKMirage Activa
NASAL MASKSELECTING A MASK
• Align the fitting template to chin crease.
• Determine cushion size according to the
position of the corner of the eye.
• Align the fitting template to bottom of the nose.
• Check the position of the chin crease above
or below the dotted line.
• If the chin crease is above dotted line,
then choose the small cushion.
• If the chin crease is below dotted line,
then choose the large cushion.
Mask Size
Mirage Quattro
FULL FACE MASK
Mirage Liberty
FULL FACE MASK
Back buckle/s 60558 (1) 60559 (10)
Short tube assembly
(short tube, elbow and swivel) 60577 Frame 60575 Pillows 60574 (XS) 60571 (S) 60572 (M) 60573 (L) Tube retainer (optional) 60586 Top buckle/s60579 (1) 60580 (10) Headgear assembly (headgear, buckles) 60578
1 Product packed with S, M and L pillows. XS sold separately.
Complete mask system
160561
• Adjust the top straps by
pulling them evenly until comfortable.
• Do not overtighten.
• Repeat Step 2 with the back
straps.
• Do not overtighten.
• Using the click-fit adjustor,
position the nasal pillows at the most suitable angle.
• Connect the Swift LT short
tube to the device air tubing.
• Turn on the device.
• The Swift LT is now fitted
and ready for use.
1
2
3
4
5
Optional
• For alternate tubing
positions, use the tube retainer.
Quick fitting guide
Minimal contact, optimal seal
• The first nasal pillows with ResMed’s proven
dual-wall technology.
• The pillows rest on a flexible cushion base
maintaining seal.
Freedom to move and sleep on the side
• Headgear with flexible stabilising elements
gently holds the system in place when user turns or moves during sleep.
• The cushion base enables the dual-wall
pillows to move in different directions without compromising seal or creating leaks.
Super-quiet and personalised comfort
• Air is dispersed gently through the fine vents. • The innovative vent design directs air away
from the user and their partner.
Do not overtighten headgear straps
• Holding the pillows at your nose, pull the headgear over your head.
• Headgear should sit midway between the ears and eyes.
• To attach, push it into the top
headgear buckle.
• Clip in either the short tube or
device air tubing, depending on flexibility needs.
• The tubing can be positioned to
either side of your face or centered.
• If the pillows pull on your nose, adjust the tubing at the tube retainer.
Pillow sleeve 60541 (S) 60542 (M) 60543 (L) Clip 60540 Seal rings 60524 (10) Frame with clip and cap
60527 Short tube assembly/ies 60528 (1) 60529 (10) Cap 60525 Frame system (no headgear)1 60537 (S) 60538 (M) 60539 (L) Tube retainer 60530 (3)
Distal pressure part
61121 (1) 61124 (10)
Headgear buckles
60523 (4)
Headgear
60526 1 Product packed with S, M & L pillows.
Complete mask system
160516
Small
16338
Medium
16339
Large
16340
Large-Wide
16341
Extra-Large
16342
Forehead pad/s 60123 (1) 60124 (10) Mask frame 16394 (Std) 16395 (S)1 Forehead support 16393 Mask cushion 16388 (S)1 16389 (M) 16390 (L) 16391 (LW) 16392 (XL) Dial 61289 Elbow 16387 Swivel 16565 Headgear clips 16569 (2) 16734 (10) Headgear 16118 (S)3 16733 (Std)2 16119 (L)3 Elbow assembly 16399 Ports cap 16570 (2) 16571 (10)1 Small cushion and frame are only compatible with each other.
2 Standard headgear supplied with all sizes of complete mask assembly.
3 Small (16118) and Large (16119) headgear come without clips.
• Turn MicroFit dial to position
24. • Disconnect one headgear clip.• Place mask on face, slide
headgear on.
• Reconnect lower headgear clip.
• Unfasten upper tabs, pull until
comfortable.
• Reattach the tabs.
• Repeat step 4 with lower
straps.
• Connect tube to mask and
flow generator.
• Start flow generator. • Turn MicroFit dial to eliminate
leaks.
1
2
3
4
5
6
Do not overtighten headgear straps
Quick fitting guide
Intuitively easy
• Easy removal of cushion and elbow from
frame (no cushion or elbow clip).
• Easy one-hand adjustment of the forehead
support with the MicroFit dial.
Personalised fit and comfort
• Allows for optimum, accurate fit with
a turn of the MicroFit dial.
• Mirage Micro dual-wall cushions now come in five sizes, to fit 95%
of patients1.
Quiet, sleek and stylish
• Quieter than a soft whisper. • Less obtrusive with minimalist
forehead support.
NASAL MASKS
1 Based on internal anthropometric database (n=267)Dial
61289
Forehead support pad/s 60123 (1) 60124 (10) Ports cap 16570 (2) 16571 (10) Forehead support 16393 Mask frame 60180 Headgear clips 16569 (2) 16734 (10) Clip 60176 Elbow 16387 Swivel 16565 Elbow assembly (elbow, swivel): 16399 Headgear 16118 (S)2 60114 (Std)1 16119 (L)2
Medium
60151
Large
60152
Large-Wide
60153
1 Standard headgear supplied with all sizes of complete mask assembly.
2 Small (16118) and Large (16119) headgear come without clips.
Mask cushion and clip 60177 (M) 60178 (L) 60179 (LW)
• Turn the MicroFit dial to position 24, so that the
forehead support is fully extended.
• Connect one end of the air
tubing to the swivel and the other end to the airflow device.
• Allow room for the cushion’s active cell to inflate. Use two
fingers as a guide.
• Turn on the airflow device. • While lying down, adjust the
dial for comfort and seal.
1
2
3
4
5
6
• If fitted incorrectly, the
cushion will be creased and the active cell underinflated.
✓
✘
✓
✘
✓
✘
✓
✘
Quick fitting guide
ActiveCell™ Technology
• The unique cushion features an ‘active cell‘
that automatically expands and contracts to suit user movements and varying pressures throughout the night.
• Ideal for active sleepers; ActiveCell Technology
provides dynamic defence against leak.
A fine-tuned fit
• MicroFit dial provides easy, one-handed forehead support adjustment.
• Less dependant on headgear tension and adjustment to achieve an effective seal (quicker fitting time, less callbacks and
improved user compliance).
The quiet achiever
• Innovative diffuse vent design, disperses air quietly and softly, at a short distance, away
from the bed partner.
• Located on the elbow for easy cleaning and
disassembly.
Do not overtighten headgear straps
• Disconnect the lower headgear
clip, hold the mask over the nose and pull the headgear over the head.
• Reconnect the lower headgear
clip ensuring it clicks into place.
• If the mask is fitted correctly,
the cushion should be smooth and the active cell (highlighted) fully inflated.
Standard
16321
Large
16322
Shallow
16323
Shallow-Wide
16324
Headgear 16118 (S)3 16733 (Std)1 16119 (L)3 Elbow assembly2 16566 Forehead pad/s 60123 (1) 60124 (10) Cushion 16556 (Std) 16557 (L) 16558 (Sh) 16735 (Sh-W) Cushion clip 16563Forehead support with pads
16590 Elbow clip 16572 16573 (10) Frame 16560 Vent cover 16575 Ports cap 16570 (2) 16571 (10) Swivel 16565 Headgear clips 16569 (2) 16734 (10) Frame assembly
(no cushion and headgear)
16595
1 Complete mask system comes with standard sized headgear.
2 Elbow assembly includes elbow clip, vent cover, elbow and swivel.
3 Small (16118) and Large (16119) headgear come without clips.
• Gently tighten upper headgear
straps. The forehead support
pads should lightly touch the forehead.
• Do not overtighten straps.
• Gently tighten lower headgear straps.
• Do not overtighten straps.
• Connect one end of air tubing
to mask swivel and other end to flow generator.
• Turn flow generator on. • If air leaks around cushion you
may need to make some
adjustments. In this case, proceed to step 5.
• Loosen upper headgear
straps and move forehead support tab to another
position (eg, position 2). • Gently tighten upper
headgear straps.
• Test all four positions of
forehead support tab and
adjust headgear straps until
you achieve a secure and comfortable fit.
1
2
3
4
5
6
Quick fitting guide
Seal and comfort
• Mirage dual-wall cushion reduces
pressure on nasal bridge and optimises seal and comfort.
• Forehead support provides seal and
stability with a choice of four clearly numbered positions.
Easy to use
• Headgear clips allow quick attachment/
detachment of headgear - no further
adjustments required after initial fitting.
Ultra-quiet
• Vent design minimises airflow
intensity and noise.
• Specially designed to direct air away
from user and partner, and provide
optimum CO2 washout.
Do not overtighten headgear straps
• Disconnect one headgear clip. • Ensure that forehead support
tab is in position 1. Place mask
on face and pull headgear over head. Make sure upper straps pass across forehead and lower straps below ears.
• Reattach headgear clip to mask frame.
1 Based on internal anthropometric database (n=267)
Forehead pad/s 60123 (1) 60124(10) Ports caps 16570 (2) 16571 (10) Forehead support 60122 Mask frame 60121 Cushion 60117 (Std) 60118 (L) 60119 (Sh) Cushion clip 60120 Elbow assembly (including exhaust vent)
60125
Inlet tube and swivel
assembly 60926 (1) 60927 (10) Headgear clip/s 60115 (2) 60116 (10)
Standard
60132
Large
60133
Shallow
60134
Headgear(Including headgear clips)
16118 (S)1
60114 (Std)2
16119 (L)1
1 Small (16118) and Large (16119) headgear come without clips.
2 Standard headgear supplied with all sizes of complete mask assembly.
Swivel assembly
60014 (10)
Small
61011
Crossover buckle Cushion2 Headgear2 Headgear clips 60023 (1), 60024 (10) 60013 (S) 61020 (S) 61025 (2), 61026 (10) Headgear Headgear clips Cushion Elbow assembly1 Frame1 60918 (Std) 60919 (2), 60920 (10) 60921 (Std), 60922 (Dp) 60925 60924Standard
60003
Deep
60004
Unobtrusive design Age 7 or over
1 These parts are common with the Kidsta.
2 The cushion and headgear on the Kidsta can be used with the Vista.
S-Std 60648 M-Std 60650 L-Std 60652 S-Sh 60649 M-Sh 60651 L-Sh 60653
Effective and comfortable
Frame 60675 (S) 60676 (M) 60677 (L) Elbow 60678 Headgear2 60917
FULL FACE MASK NASAL MASK
Standard 60401 Large 60402 Shallow 60403
A more unobtrusive option for NIV
Elbow assembly 60916 Frame 60915 Forehead support 16562 Forehead pad/s 16561 (2) 16574 (10) Tube connector/s 60913 (1) 60914 (10)
1 Common parts with Ultra Mirage Full Face Mask: forehead pads, headgear clips,
cushion & clips,elbow retainer, forhead support and ports caps.
2 This part is common with Ultra Mirage Nasal Mask NV.
3 Common parts with Ultra Mirage II: cushion & clip, elbow clip, headgear clips & ports cap.
NON-VENTED MASKS
1
Ultra Mirage NV
3Small
60720
Medium
60721
Large
60722
Small
60700
Medium
60701
Large
60702
Medium
61104
Large
61105
Disposable
A more unobtrusive option for NIVDisposable
Easy to seal
Disposable NV
For use with a leak circuit
Headgear
60710 (10)
Headgear
60711 (10)
DISPOSABLE MASKS
FULL FACE MASK NASAL MASK
Technical Specifications
Ultra Mirage II Nasal
Mirage Quattro, Mirage Liberty, Ultra Mirage, Hospital Full Face Mask Mirage Swift II Nasal Pillows
Swift LT Nasal Pillows
Mask–Device Compatibility
MASK–DEVICE COMPATIBILITy
The table below specifies the masks compatible with ResMed’s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides.
Nasal Pillows
Mirage Swift II
Swift LT
S7 AutoSet Spirit™ MIRAGE MIRAGE S8 AutoSet Spirit™ II SWIFT SWIFT
S8 Escape™ II No setting required. Consult your clinician before changing to a different mask type. VPAP™ III Series MIRAGE MIRAGE AutoSet CS™ 2 N/V N/V
Mask–Device Compatibility
The table below specifies the masks compatible with ResMed’s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides.
Nasal Masks
Mirage
Micro
Ultra
Mirage II
Activa
LT
Mirage
Activa
Mirage
Vista
Mirage
Kidsta
S7 AutoSet Spirit STANDARD ULTRA STANDARD STANDARD STANDARD STANDARD S8 AutoSet Spirit II STANDARD ULTRA ACTIVA ACTIVA STANDARD STANDARD S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series STANDARD ULTRA STANDARD STANDARD STANDARD STANDARD AutoSet CS 2 VISTA ULTRA ACTIVA ACTIVA VISTA N/V
N/V = The mask has not been validated for this device.
Mask–Device Compatibility
Full Face Masks
Mirage Quattro
Mirage Liberty
Ultra Mirage
S7 AutoSet Spirit MIR FULL MIR FULL MIR FULL S8 AutoSet Spirit II MIR FULL MIR FULL MIR FULL S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series MIR FULL MIR FULL MIR FULL AutoSet CS 2 FULL FACE FULL FACE FULL FACE
The table below specifies the masks compatible with ResMed’s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides.
Mask–Device Compatibility
Disposable Masks
Hospital Nasal
Hospital Full Face
S7 AutoSet Spirit STANDARD MIR FULL S8 AutoSet Spirit II STANDARD MIR FULL S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series N/V MIR FULL AutoSet CS 2 VISTA FULL FACE
N/V = The mask has not been validated for this device.
The table below specifies the masks compatible with ResMed’s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides.