Monitorowanie parametrów SLA oraz
SAT (Service Activation Test) w oparciu
o urządzenia CE2.0 Raisecom
Agenda
Monitorowanie parametrów SLA w oparciu o Y.1731
-
Y.1731 – podstawy
- Konfiguracja EDD ISCOM RAX711
- Cacti - prezentacja wyników w formie graficznej
SAT (Service Activation Test) w oparciu o Y.1564
- Y.1564 – podstawy
RAX711 (A)
Y.1731 – podstawy
• IEEE 802.1ag: Connectivity Fault Management (CFM) • IEEE 802.3ah: Ethernet Link OAM (EFM OAM)
• ITU-T Y.1731: OAM functions & mechanisms for Ethernet based networks • MEF E-LMI: Ethernet Local Management Interface
• IP SLA’s: Performance Management using CFM and Y.1731 mechanisms
Y.1731 – podstawy
• Link Level OAM
• Operates on point-to-point, not propagated beyond a single hop • Slow Protocol – (Max rate of 10 frames per second)
Functions:
• OAM discovery
• Link monitoring – Event notification when error thresholds exceeded • Remote Failure Indication
Y.1731 – podstawy
• Maintenance Association End Point (MEP)
• Support the detection of connectivity failures between any pair of MEPs in an MA • Associated per MA and identified by a MEPID (1-8191)
• Ethernet frames realizing functions:
ETH-CC (Ethernet Continuity Check - Fault detection) ETH-LB (Ethernet Loopback - Fault acknowledgement) ETH-LT (Ethernet Link Trace - Fault location)
Y.1731 – podstawy
• Performance Measurement:
ETH-DM (Frame Delay/Jitter Measurement) ETH-LM (Frame Loss Measurement)
• ETH-AIS (Alarm Indication Signal) • ETH-RDI (Remote Defect Indication) • ETH-LCK (Ethernet Locked Signal)
Y.1731 – podstawy
Maitenance
Domain (MD) &
Level
• CFM packet in a lower-level MD is discarded after entering a higher level MD. • CFM packets in a higher-level MD can traverse lower-level MDs
• MD may nest and touch, but never intersect • Up to eight MD levels: (0..7)
Y.1731 – podstawy
Maitenance
Association
(MA)
• Monitors connectivity of a particular service instance ina a MD • Defined by a set of Maintenance End Points (MEP)
Y.1731 – podstawy
Maitenance
End Point
(MEP)
• Defines the boundaries of a MD
• Support the detection of connectivity failures between any pain od MEPs in MA • Associated per MA and indetified by MEPID (1-8191)
Y.1731 – podstawy
Maitenance
Internediate
Point (MIP)
• Support discovery of paths among MEPs and location of faults along those paths • Can be associated per MD and VLAN/EVC (automatically created)
Konfiguracja EDD ISCOM RAX711 (EDD-1)
• hostname EDD-1 • create vlan 108 active • interface gigaethernet 0/1 • switchport mode trunk
• switchport trunk allowed vlan add 108
• network-interface-id EDD-1-gigaethernet0/1 • interface gigaethernet 1/1
• switchport mode trunk
• switchport trunk allowed vlan add 108
• network-interface-id EDD-1-gigaethernet1/1
NNI1 NNI1
Konfiguracja EDD ISCOM RAX711 (EDD-1)
• ethernet cfm enable
• ethernet cfm domain md-name md7 level 7 • service ma7 level 7
• service vlan-list 108 primary-vlan 108 • service remote-mep 2 gigaethernet 1/1
• service mep up mpid 1 gigaethernet 1/1 priority 3 • service pm enable mep 1
Konfiguracja EDD ISCOM RAX711 (EDD-1)
eline md7ma7
sap gigaethernet 1/1 (Service Access Point) sdp vlan 108
Konfiguracja EDD ISCOM RAX711 (EDD-2)
• hostname EDD-2
• create vlan 108 active • interface gigaethernet 0/1 • switchport mode trunk
• switchport trunk allowed vlan add 108
• network-interface-id EDD-2-gigaethernet0/1
• interface gigaethernet 1/1 • switchport mode trunk
• switchport trunk allowed vlan add 108
• network-interface-id EDD-2-gigaethernet1/1
• ethernet cfm enable
• ethernet cfm domain md-name md7 level 7 • service ma7 level 7
• service vlan-list 108 primary-vlan 108 • service remote-mep 1 gigaethernet 1/1
• service mep up mpid 2 gigaethernet 1/1 priority 3 • service pm enable mep 2
• service cc enable mep 2
• eline md7ma7
• sap gigaethernet 1/1 • sdp vlan 108
Konfiguracja EDD ISCOM RAX711 (EDD-2)
• sla 1 y1731-jitter remote-mep 1 level 7 svlan 108 cos 1 • sla 2 y1731-pkt-loss remote-mep 1 level 7 svlan 108 cos 1 • sla 3 y1731-jitter remote-mep 1 level 7 svlan 108 cos 3 • sla 4 y1731-pkt-loss remote-mep 1 level 7 svlan 108 cos 3 • sla schedule 1 life forever
• sla schedule 2 life forever • sla schedule 3 life forever • sla schedule 4 life forever
Cacti - prezentacja wyników w formie graficznej
SAT (Service Activation Test) w oparciu o Y.1564
• CIR - Committed Information Rate • EIR - Excces Information Rate
SAT (Service Activation Test) w oparciu o Y.1564
• FD – Frame Delay
• FDV – Frame Delay Variation (Jitter) • FLR – Frame Loss Rate
• FDR - Frame Delay Range • Availability
Konfiguracja EDD ISCOM RAX701 (EDD-B)
• hostname EDD-B • config
• create vlan 100 active • interface line 1
• switchport mode trunk
• switchport trunk allowed vlan 100 confirm • loopback smac 000E.5E4F.CCC6
• loopback mode rc-l2 • exit
• interface client 1
Konfiguracja EDD ISCOM RAX701 (EDD-A)
• hostname EDD-A • config
• create vlan 100 active • interface line 1
• switchport mode trunk
• switchport trunk allowed vlan 100 confirm • interface client 1
• switchport mode access • switchport access vlan 100 • rcsam cir step 25 50 75 100
• rcsam performance-test duration 1 (m)
• rcsam service 1 l2-eth • uni client 1
• dmac 000E.5E4F.CCC4 • frame-size fix 128
• cvlan 100
• cir 100000 cbs 128 eir 10000 ebs 128 • traffic-policing rate 112500
• service enable
• rcsam configuration-test enable • rcsam performance-test enable • rcsam test start
ul. Śnieżna 18 30-822 Kraków
Telefon: +48 (12) 294 00 01 Faks: +48 (12) 294 02 50