SUPPLEMENT NUMBER: SU-10073-6910A

TO

PUBLICATION NUMBER: 10073-0020

Copyright @ 1983 By Harris Corporation All Rights Reserved

HARRIS CORPORATION RF COMMUNICATIONS GROUP 1680 University Avenue Rochester, New York 14610 U.S.A.

Tel: 716-244-5830 Cable: RFCOM; Rochester, N.Y. TELEX: 978464

1--

(2)

TABLE OF CONTENTS

Paragraph Page

1 1 1

RF-553-01 Remote Control Adapter General Description.

Functional Description.

PartsList

2 3

LIST OF FIGURES

Figure

1 2 3 4 5

2 3 5 7 8 1-

:-

A241nterfacePWBLocation

A24 Component Location ( 10073-6900)

A24Schematic Diagram (10073-6901)

A24 InterconnectCableAssembly(10073-6917)Interface PWB Interconnect Diagram.

f~

LIST OF TABLES

1'--

Table

1 2 3

9 9 9

A24lnterfacePWBPartsList. I n/Out Interconnect Cable Cable Assembly Parts Parts List. List

1-

~

J-

(3)

m HARRI S RF COMMUNICATIONS

RF-553-01 REMOTE CONTROL ADAPTER GENERAL DESCRIPTION

The RF-553-01 Remote Control Adapter enables the RF.551A/552 Preselector to be remotely controlled by the RF-590 Receiver. This option consists of A24 Interface PWB (10073-6900) and necessary intercon- necting cables and connectors.

The A24 Interface PWB (10073-6900) is ured to convert serial data from the RF-590 to parallel data for use with either preselector. Serial data is supplied to J2 of A24 Interface PWB from A 14 Control PWB through W21. Parallel data to the remote preselector is sent through Interconnect Cable W41

(10073-6917) from J9 on the rear panel of the R F-590 Receiver. Figure 1 shows the location of the A24 Interface PWB on the RF-590 Receiver Chassis.

2.

FUNCTIONAL DESCR IPTION

Refer to the component location diagram, figure 2; schematic diagram, figure 3; Interface (A24) I ntercon- nect diagram, figure 4; and Interconnect Cable diagram, figure 5 through this discussion.

Upon initial turn on of the RF-S90, R10, C13 and inverter U7 produce the trailing-edge-triggering for US.

US enables the shift registers U1, U2, and U3 and gated buffers U4, US, and U6 to load frequency informa- tion to the pre,selec;tor.

Serial data from'the RF-590 is clocked into U1, U2, and U3 and latched with strobe 1. US is a retrigger- able one shot that enables frequency information to be sent to the preselector ~ 1 second after a frequency change. When a frequency change is made, strobe 2 is generated causing US to disable the shift registers while data is being loaded. Once data is loaded and strobe 2 remains in a low state, US 5:A. enables the shift registers after a one second delay set by C9, R 1 time constant.

If frequency changes are made at less than one second intervals, the preselector will not respond. A bypass signal is provided for system applications. There is no bypass mode in the RF-551/552 Preselector, a large degradation in sensitivity will be noted for a large frequency change due to the one second delay of frequency information to the preselector.

US OB signal is delayed 0.1 milliseconds by R7 and C4 to allow frequency information to be loaded into U4, US, and US from the shift registers. RS and CS produce a 1 millisecond delay before U4, US, and US are latched holding the frequency data to the preselector.

3.

PARTS LIST

Table 1 is a comprehensive parts list for the A24 Interface PWB Assembly. Tables 2 and 3 are the parts lists for the cable assemblies used in this option.

1

(4)

-1

I . t

I t t

I I t

I

Figure 1. A24 Interface PWB Location

(5)

m HARRIS RF COMMUNICATIONS

Figure 2. A24 Component Location (10073-6900)

3/4

(6)

W43Pl

J1

+5V

UN REG. TO A 16A2

REAR POWER DISTRIBUTION ASSY

1 2 3 4 S

2 3 4 5

GND

J2 W41

Jg REAR PANEL ASSY 1 !

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 GND 2MHZ 1 MHZ 4MHZ 20 MHZ

8 MHZ 10 MHZ

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

IP1 J9-1

'&

J9-26

BYPASS 8 KHZ 100 KHZ 4 KHZ 200 KHZ 80 KHZ 10 KHZ 2 KHZ

J9-13 1

20 40 400

~

.19.31

J9-33

800 K HZ

W21P6 J3

INDEX DATA STROBE 2

ClOCK STROBE 1

1 2 3 4 5

1 2 3 4 5

/1 :::=.=?

A14 CONTROLBOARO ASSY

KHZ KHZ KHZ KHZ

(7)

m HARRIS RF COMMUNICATIONS

.,--, P1

"";"[

I Q P2

t I

II

2 3 4 I

5 6 7 8 9 tO I

tt I I t2 13 14 1~

16 17 18 19 i 201 , 21 22 23 24 !

25 26 27 28 29 30 31 32 33 34 35 36 37

u

s

E D J C B H

p R T

K L F

G M N

Figure 5. Interconnect Cable Assembly Diagram

8

(8)

Table 1. A241nterface PWB Parts List

Description

Ref. Desig.

Part No.

10073-6900 CK06BX104K C26-0016-330 C26-0025-339 CK06BX104K C26-0016-330 J46-0032-005 J46-0031-026 J46-0032-005 MS75085-13 R65-0003-303 R65-0003-473 R65-0003-103 R65-0003-102 R65-0003-473 101-0000.156 105-0000.373 f{)1-0000.018 101-0000.353 C1-CS

cg C10 C11, C12 C13 J1 J2 J3 L1 R1 R2-R4 R5, Re R7 RS-R10 U1-U3 U4-Ue U7 US

-

Interface PWB Assembly

Capacitor, Ceramic, 1 u F, 100 V Capacitor, 33 u F

Capacitor, 3.3 uF

Capacitor, Ceramic, 1 uF, 100 V Capacitor, 33 u F

Connector, 5 Pin Connector, 26 Pin Connector, 5 Pin Coil

Resistor, Carbon, Film, 30K, 1/4 W, 5%

Resistor, Carbon, Film, 47K, 1/4 W, 5%

Resistor, Carbon, Film, 10K, 1/4 W, 5%

Resistor, Carbon, Film, 1K, 1/4W, 5%

Resistor, Carbon, Film, 47K, 1/4W, 5%

Integrated Circuit, CMOS, CD4094BE Integrated Circuit, 74LS373

Hex Inverter -Buffer

Dual Monostable, CD4538BEX

Table 2. In/Output Cable Assembly Parts List

Table 3. Interconnect Cable Parts List

(9)

References

Related documents

There are so many variables which determine the self- employment in different ways but in this study we took some significant variables such like Age, Sex, Marital Status,

Relative power spectra for the beta band during stage 2 for both groups (insomnia patients and good sleepers) and each areas (others vs prefrontal).. prefrontal cortical activity in

Interconnect Cable will be paid for at the contract unit price which shall be full compensation for furnishing and installing the interconnect cable with the number of conductors and

MODELS, plus steam pressure limit control with siphon; pressure gauge; low water cutoff and water level sight glass (unmounted); drain cock, transformer and junction box..

• The C-arm position is in 0° orbital (center position) and 180° angulation (X-ray image in- tensifier below, tube on top, one turn of the cable around the angulation axis,.. see

ALL RIGHTS RESERVED WYS52FX730V

8.4 Therefore, where flush-mounted accessories penetrate each face of a 30 minute fire separating or loadbearing plasterboard lined wall within the same cavity space (that is, the

Number Part Number Parts Name Number Required Remarks 1 KF04093AA Fuel Tank Assy... Number Part Number Parts Name Number Required Remarks 1 KS02056AD Recoil