(1)

www.ave.it +39 030 24981

sta118-sett08-i

(2)

2

3

pag 4

pag 8

pag 10

pag 14

A totally innovative solution based on “invisible” modules sensitive to touching the surface of the glass plate, provided with LEDs and tactile sensors.

Series characterised by designed evolution and various technological features, available in a wide range of aesthetic properties.

Series conceived in the spirit of traditional and functional design, with technological solutions suitable for any environment, cur-rently incorporating all “Sistema 44” innova-tions.

Since 1904, the days of my great grandfather, we have been key players in uncountable technological evolutions. However, 2008 definitely marked a turning point, the beginning of a new era. The object you are holding in your hands right now is the fruit of a journey characterised by research, innovation, investments and passion which bore DOMINA HOTEL. DOMINA HOTEL marks an important development with respect to hotel industry standards.

DOMINA HOTEL represents cutting-edge research solutions and advanced design flexibly fully meeting hotel management needs ranging from small hotels to the large multinational hotel chains. An Ave tagged revolution, I am proud to say, entirely made in Italy.

AVE

Welcome to Ave. Dott. Alessandro Belli President of AVE s.p.a.

(3)

4

5

Just one touch to step into a new era, the past fades away, simply outlived. Ave

Touch comes in an awesome range of products adorning the most advanced technology with physical beauty, tactile. Ave touch obeys your orders, turning dre-ams into desires. Touch, listen and watch the environment you yearned for finally take shape.

AVE TOUCH 3+3

With room transponder reader personalisable with room number and hotel logo

AVE TOUCH

With slide for covering sockets

AVE TOUCH

Sign with graphic “step-marker” function, interchangeable and personalisable with hotel logo.

Personalisable room access client card.

4

5

AVE TOUCH

(4)

6

7

6

7

AVE TOUCH switches

With regulation of sensitivity to touch Personalisable with hotel logo AVE TOUCH

“Wall-flushed” installation

A special box allows perfect wall-flushed in-stallation, leaving only the magnificent Ave Touch surface exposed.

AVE TOUCH signs

With interchangeable and personalisable symbols Personalisable with hotel logo

AVE TOUCH switches

With interchangeable and personalisable symbols Personalisable with hotel logo

(5)

8

9

8

9

Choice and appreciation are innate traits of human beings. Ave Life 44 meets this need by combining technology with design and specifically made material. An authentic treat for your eyes.

LIFE 44

LIFE 44

Extractable emergency lamp

Glass VERA 44 plate personalisable with hotel logo

Metal ZAMA 44 plate

Paintable and personalisable with hotel logo. Classy frame for breathtaking environments.

AVE patents n° 196

LIFE 44 Electronic thermostat Switches

Fibre optics illuminated frame Glass VERA 44 plate

Ideal combination with AVE TOUCH devices Personalisable with hotel logo.

The glass plate that that ushers a touch of elegance into any room.

(6)

10

11

10

11

Switches PERSONAL 44 plate personalisable with software

AVE patents n° 196

Sockets PERSONAL 44 plate personalisable with software Programmable thermostat

External doorframe sign PERSONAL 44 plate Personalisable with software

(7)

12

13

Gratifying simplicity. Combining a wide range of colours and functionality DOMUS 100 is the perfect key to a lively and blissful system.

12

13

DOMUS 100

Step-marker

PERSONAL 44 plate personalisable with software

Personal 44 with modern design, comes in a wide range of technological colours and with mirror effect, also available in transparent version with personalisable graphic and colours. Graphic persona-lisation may also be performed by the end client by means of a programme available at our website

www.ave.it free of charge.

Brevetti AVE n°196 208 209 19145

VERA 44 for round box Best for restoration

Personalisable with hotel logo

Shaver socket

Glass VERA 44 plate Personalisable with hotel logo

Switch

Metal ZAMA 44 plate Personalisable with hotel logo Extractable emergency lamp

Glass VERA 44 plate personalisable with hotel logo

Control unit

Coordinated with the Sistema 44 plates Personalisable with hotel logo

Shifter TECNOPOLIMERO 44 plate Personalisable with hotel logo Made of technopolymer, not only is Tecnopolimero 44

suitable for any environment but it also incorporates all the Sistema 44 innovations.

(8)

14

15

Technical catalogue

contents

Stand-alone system:

125kHz technology... page 20

MIFARE technology... page 26

125kHz and MIFARE technology common products... page 32

Network system:

MIFARE technology... page 38

Network and stand-alone systems common products... page 48

Codes summary:

Stand-alone system ... page 52

Network system... page 53

Compatibility with S45... page 54

Installation examples:

Stand-alone systems... page 58

network systems... page 62

Hotel room radio components... page 66

Electrical diagrams... page 70

(9)

16

17

Domina Hotel, a single system Meeting all your hotel needs

AESTHETIC TOUCH:

The plates are entirely personalisable and

configurable to suit your needs.

Further-more, they can bear, depending on the model, your

hotel logo, room number and any other indication adding a

personalised and unique classy touch to your hotel. Plates

and devices made of various material and finishing are

avai-lable.

SCALABILITY

The AVE Domina Hotel systems suits all needs, both in

terms of costs and performance. We have a simple and

inexpensive system for small hotel operators, extremely

suitable for an environment not requiring particularly

so-phisticated solutions. The bigger the hotel the more our

system meets your ever-growing needs up to providing a

complete network system for monitoring the rooms and

any type of environment, even in big hotels. If you

ex-pect to expand with time, no need to worry we have the

right solution for you. As a matter fact, the AVE Domina

Hotel system requires just a few updates to match the

growth of your business without forcing you to start from

scratch, helping you preserve your investments over time.

RELIABILITY

AVE hotel systems are not just about aesthetic properties,

but also reliability. Each room can be monitored by a central

computer at the reception. However, in case of computer

failure, the whole system operates as usual, losing only the

remote room monitoring while awaiting repair of the failure.

The system is at its best when it operates in its entirety but

each device continues operating independently even in case

of failure of the other components. Furthermore, the islands

system, wherein each room not only operates independently

but is also connected to the main network, ensures that no

in-dependent failure brings the entire hotel system to a standstill.

COMFORT

AVE hotel devices are client-oriented, offering utmost

comfort during his stay at your hotel. The thermostat,

which is easy to use and intuitive, allows regulating the

room temperature. The signalling system allows the client

to decide when and whether to be disturbed. The room

service personnel shall not ring the doorbell or open the

door by mistake while the client is in the room. The

remo-te control allows the client to operaremo-te the devices (loads)

comfortably from his seat.

EFFICIENCY AND ENERGY SAVING

IConstant monitoring from the reception shall keep you

constantly informed, allowing you to intervene

prom-ptly to curb poor quality services. Furthermore,

Do-mina Hotel allows optimising management and

ke-eping energy consumption under control allowing

considerable saving. This implies greater customer

sa-tisfaction, a more efficient hotel and lower running costs

TECHNOLOGY

AVE hotel management products use the contactless Mifare

and 125kHz technology. The access cards are entirely safe

and clone-proof thus leaving you and your clients entirely sure

that no ill-intentioned person will have an easy time in your

premises. The possibility to integrate

e-mo-ney systems (not provided by AVE) allows you

to offer your clients an entirely new range of

services, accessible through the same card

which shall also serve as a payment system.

(10)

18

19

Stand-alone hotel

(11)

20

21

External reader

Cod. Description Modules

441GA01-T

442GA01-T

External readers are devices which, by me-ans of a trme-ansponder card, allow controlling access to hotel rooms and premises. The-se readers are capable of independently managing their entries and exits in such a manner to be able to operate even without requiring other devices of the same hotel series.

The devices may be configured for access to 4 different types of areas:

• ROOMS: access allowed for all enabled client cards and for the service personnel cards at given conditions (e.g. the room service personnel card operates only when the room is not occupied).

• SERVICE ROOMS: access allowed for service personnel cards but not for the client cards.

• COMMON AREAS: access allowed both for service personnel and client cards.

• SCALABLE ACCESS: access allowed for enabled service personnel cards. For access, client cards require sufficient credit consisting in a number of accesses. The device updates the card reducing the credit at each access.

Compliance with standards

• R&TTE 1999/5/EC Directive – Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmoni-sed standards

• EMC Directive 2004/108/EC.

In compliance with the following harmoni-sed standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007

• LVD 2006/95/EEC. In compliance with EN 60950-1:2006 harmonised stan-dards

Auxiliary relay outputs

• Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1)

• Maximum applicable load (CC): 5A @ 30Vdc

• Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4)

• Duration of contact (electric): 50.000 manoeuvres maximum load) • Maximum switching (electric) frequency: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) fre-quency:

18.000 cycles/hr.

Electrical features

With DC power supply

• Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 80mA • Maximum absorption (@ +12Vdc):_ 150mA With AC power supply

• Supply voltage: 12Vac ±30% • Allowed supply frequency: 50 ÷ 60Hz • Stand-by absorption (@ 12Vac): _ 200mArms

• Maximum absorption (@ 12Vac): _ 250mArms

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 9 mm (from plate wire)

• Active area lighting: by means of low-absorp-tion high-efficiency blue LEDs

• Degree of protection: IP 40

• Terminal boards: 2 + 2 + 10 poles 12A - 250V

• Programming connector: Female stereo jack d=2.5mm

• Blue LED light for identification in the dark

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

Transponder Technology

• Means: ISO7816 (credit card format) • Transponder: RFID 125kHz Opt64

441GA01-T

442GA01-T

441GA01-T Transponder-equipped external reader - 125kHz 3 Domus 100 series

442GA01-T Transponder-equipped external reader - 125kHz 3 Life44 series

Terminal Colour Description

A Green “A” Rs-485 B Green “B” Rs-485

- Black - Supply (Common inputs) + Black + Supply

1 Green Room status Input 2 Green Courtesy Light Input 3 e 4 Green Courtesy Light Output

5 Green Common for Terminals 6, 7 and 8 6 Green Electric Lock Output

7 Green Bell Output 8 Green “Guest In” Output

DESCRIPTION OF TERMINAL BOARD

OVERALL DIMENSIONS

67,5 mm

55,5 mm

45 mm

Stand-alone system with

(12)

22

23

Internal reader (room)

441GA30-T

442GA30-T

Internal readers are devices to be positio-ned inside the premises to be managed to allow actuation of room loads and services only in presence of an enabled card. Such readers are capable of independently ma-naging their inputs and outputs in such a manner to be able to operate even without requiring the other devices of the same ho-tel series.

Furthermore, they are capable of commu-nicating with other devices such as room control unit, transponder card external rea-der (for access to premises), environment thermostat and transponder card program-mer.

The readers are provided with two auxiliary inputs for detecting the state of dry con-tacts (voltage free concon-tacts) and with four output relays (still for dry contact).

Electrical features

With DC power supply

• Supply voltage: +12Vdc ±25% • Stand-by absorption (@ +12Vdc): _ 80mA

• Maximum absorption (@ +12Vdc): _ 150mA

With AC power supply • Supply voltage: 12Vac ±30% • Allowed supply frequency: 50 ÷ 60Hz

• Stand-by absorption (@ 12Vac): _ 200mArms

• Maximum absorption (@ 12Vac): _ 250mArms

Compliance with standards

• 1999/5/EC Directive – Made of Class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards

• EMC Directive 2004/108/EC.

In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007

• LVD 2006/95/EEC. In compliance with EN 60950 1:2006 harmonised standards

Auxiliary relay output

• Maximum applicable load (resistive A.C.):

5A @ 250Vac (cosϕ 1)

• Maximum applicable load (CC): 5A @ 30Vdc

• Maximum applicable load (inductive A.C.):

3A @ 250Vac (cosϕ 0.4) • Duration of contact (electric): 50.000 manoeuvres maximum load) • Maximum switching (electric) frequency: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) frequency 18.000 cycles/hr.

Mechanical features

Mechanical features • Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 9 mm

(from plate wire)

• Active area lighting: by means of low-absorp-tion high-efficiency blue LEDs

• Degree of protection: IP 40

• Terminal boards: 2 + 2 + 10 poles 12A -250V

• Programming connector: JFemale stereo jack d=2.5mm

• Blue LED light for identification in the dark

Climatic conditions

• Reference relative temperature and hu-midity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

Transponder technology

• Means: ISO7816 (credit card format) • Transponder: RFID 125kHz Opt64

441GA30-T

442GA30-T

DESCRIPTION OF TERMINAL BOARD

OVERALL DIMENSIONS

Terminal Colour Description

A Green “A” Rs-485 B Green “B” Rs-485

- Black - Supply (Common inputs + Black + Supply

1 Green Room Light Input 2 Green Window Contact Input 3 e 4 Green Room Light Output

5 Green Common for Terminals 6, 7 and 8 6 Green Air Conditioner Enabling Input 7 Green Load Control Output (FEM) 8 Green “DO NOT DISTURB” Output

67,5 mm

55,5 mm

45 mm

Cod. Description Modules

441GA30-T Transponder-equipped external reader with pocket 3 - 125kHz Domus 100 series

442GA30-T Transponder-equipped external reader with pocket 3 - 125kHz Life44 series

Stand-alone system with

(13)

24

25

Card programmer

Card

SCR-ALB04

44339CHM-T

44339CHU-T

Item SCR-ALB04 is a transponder card programmer (125KHz) capable of com-municating with the hotel series devices. SCR-ALB04 is provided with a USB inter-face (compatible with 1.1 and 2.0 USB specifications), which allows directly inter-facing the programmer to a monitoring PC for programming the transponder card and/or programming all 125kHz hotel ma-nagement devices.

In order for item SCR-ALB04 to operate, it is required to be connected to a PC pro-vided with a special card programming software supplied as a kit. There are two types of software: the first basic one inten-ded for the end user and a more technical one meant for installers and/or technical assistance centres.

Light signals (LEDs)

• L1 (Red): NOT EXEC

Indicates that the last command sent has not been executed correctly.

• L2 (Green): EXECUTED

Indicates that the last command sent has been executed correctly

• L3 (Yellow): WAIT

Indicates that the programmer is free and ready to receive new commands (blinking)

Mechanical features

• Container: 123 l x 30 h x 68 p mm • Material: ABS (UL 94 HB)

• Colour: Black (Ral 9005) • Degree of protection: IP40 • PC interface: USB 1.1/2.0 (Type B connector)

• ARMBus interface: Stereo Jack 2.5mm

• Compatible with all 125kHz hotel system elements

Operating mode

The SCR-ALB04 transponder card rea-der/programmer may be used both as a simple device for programming transpon-der cards used for 125kHz hotel mana-gement (alongside a user software) and in combination with a further software (meant for technicians and/or installers), as a pro-grammer for all modules made for hotel management. As a matter of fact, it allows updating management firmware and/or modifying configuration parameters of the various devices of the 125kHz hotel seri-es.

Furthermore, it allows monitoring traffic both on the room Bus (Sniffer) bearing all the messages and/or commands circula-ting in the Bus itself.

or that it is completing the execution of a previous command (fixed light).

• L4 (Yellow): TX

Indicates that a communication from the SCR-ALB04 programmer to the PC throu-gh interface is in progress.

• L5 (Yellow): RX

Indicates that a communication from the PC to the SCR-ALB04 programmer throu-gh interface is in progress.

Electrical features

• Supply voltage (DC):

+5Vdc ±10% self supplied through USB port

• Stand-by absorption (@ +5Vdc): _ 50mA

• Maximum absorption (@ +5Vdc): _ 100mA

• USB interface compatibility: USB1.1/2.0

Climatic conditions

• Reference relative temperature and hu-midity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

SCR-ALB04

44339CHM-T

44339CHU-T

Cod. Description Modules

Cod. Description Modules

SCR-ALB04 Transponder card programmer 125kHz -SFW-ALB04 software included

SFW-ALB04 Card generation software

Generates a 125kHz or MIFARE card depending on -the programmer used

SFW-ALBTECSystem configuration software for technicians and installers

-44339CHM-T 125kHz Master Transponder Card -Card format: ISO7816

44339CHU-T 125kHz User Transponder Card -Card format: ISO7816

ROOM STATUS:

The AVE stand-alone system software allows a constant update on which rooms are reserved and for how long. Management of the rooms allows monitoring the situation and avoiding un-pleasant inefficiency for the clients as well creating client cards with expiry dates..

PERSONNEL MANAGEMENT: Personnel management allows constant monitoring of the situation and genera-ting premises access cards allowing the hotel personnel to perform its duties in an easy manner. The room service personnel may enter the rooms for cleaning and tidying, but only when the room is not occupied by the client hence avoi-ding unpleasant inconveniences. The maintenance personnel shall have access to all premises without restrictions except for the rooms occupied by the clients.

SCHERMATE DI ESEMPIO

The 125kHz cards used for hotel manage-ment are provided with a rewritable memo-ry equivalent to 1kb.

44339CHM-T Card master

The system is conceived to use a Master card in order to be able to perform any card preparation and/or programming opera-tion. This Master card has its own unambi-guous code called “Hotel Code” which is transferred to the reader through the same Master in the direct programming step alongside any other required data and a

sonnel card programming step, it is tran-sferred on all the programmed cards through the reader itself. In case of failure or lack of the SCR-ALB04 programmer, all the access card programming opera-tions may be performed by using the Ma-ster card, following procedures outlined in the reader instructions.

44339CHU-T User card

User cards allow access to or use of a service. These cards are of the following types: CLIENT, ROOM SERVICE PER-SONNEL, MAINTENANCE PERPER-SONNEL, PASSEPARTOUT,

SUPER-GUEST, SUB-MASTER, MASTER COPY, ERASER.

“Progressive Room Code” automatically increased by the reader after the first con-figuration.

Systems divided into several zones and/or several sub-systems may be built. In this case, the system must be provided with a Master card for each of the predetermined combinations (e.g. 3 zones and 2 sub-systems = 6 Master cards). NOTE: The Master card (or Master cards) serves as an identification for the system and it should be preserved with care for possible future configurations.

The system code received by the Master card (alongside the sub-system code and zone code), is memorised by the reader and, during the client and/or service

per-Stand-alone system with

(14)

26

27

442GA01-M

442GA02-M 441GA01-M

External reader (room)

441GA01-M

442GA01-M

External readers are devices which, through the use of MIFARE cards, allow controlling access to the hotel rooms and premises, and they are capable of operating even without requiring other devices of the same hotel series. MIFARE technology allows generating cards having higher security level and integrating advanced services (e-mo-ney) therein with topmost level reading performance.

The devices may be configured for ac-cess to 4 different types of areas: • ROOMS: access allowed for all enabled client cards and for the service personnel cards at given conditions (e.g. the room service personnel card operates only when the room is not occupied).

• SERVICE ROOMS: access allo-wed for service personnel cards but not for the client cards.

• COMMON AREAS: access allo-wed both for service personnel and client cards.

SCALABLE ACCESS: access allowed for enabled service personnel cards. For access, client cards require sufficient credit consisting in a number of accesses. The device updates the card reducing the credit at each ac-cess.

Climatic conditions

• Reference relative temperature and hu-midity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

Auxiliary relay outputs

• Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ1)

• Maximum applicable load (CC): 5A @ 30Vdc

• Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ0.4)

• Duration of contact (electric): 50.000 manoeuvres maximum load) • Maximum switching (electric) frequency: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) frequen-cy 18.000 frequen-cycles/hr.

Compliance with standards

• R&TTE 1999/5/EC Directive – Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards

• EMC Directive 2004/108/EC.

In compliance with the following harmonised stan-dards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007

• LVD 2006/95/EEC. In compliance with the EN 60950-1:2006 harmonised standards

OVERALL DIMENSIONS

Electrical features

With DC power supply • Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 80mA • Maximum absorption (@ +12Vdc): _ 150mA

With AC power supply • Supply voltage: 12Vac ±30%

• Allowed supply frequency: 50 ÷ 60Hz

• Stand-by absorption (@ 12Vac): _ 200mArms

• Maximum absorption (@ 12Vac): _ 250mArms

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 9 mm (from plate wire) for the Domus 100 series and Life44, while the AveTouch 442GA02-M code is beneath the components wire

• Active area lighting: by means of low-absorp-tion high-efficiency blue LEDs

• Degree of protection: IP 40

• Terminal boards: 2 + 2 + 10 poles 12A -250V

• Programming connector: Female Stereo Jack d=2.5mm

• Blue light for identification in the dark

MIFARE technology

• Means: ISO7816 (Credit card format) • Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard)

Terminal Colour Description

A Green “A” Rs-485 B Green “B” Rs-485

- Black - Supply (Common inputs) + Black + Supply

1 Green Room Status Input 2 Green Courtesy Light Input 3 e 4 Green Courtesy Light Output

5 Green Common for Terminals 6, 7 and 8 6 Green Electric Light Output

7 Green Bell Enabling Output 8 Green “Guest IN” Output

DESCRIPTION OF TERMINAL BOARD

OVERALL DIMENSIONS

67,5 mm

55,5 mm

45 mm

Stand-alone system with

MIFARE technology

Stand-alone system with

MIFARE technology

Cod. Description Modules

441GA01-M External reader – MIFARE 3 Domus 100 series

442GA01-M External reader – MIFARE 3 Life44 series

442GA02-M External reader AVETouch – MIFARE 3 AVETouch series

442GA02-M application examples Available upon request

(15)

28

29

442GA30-M

441GA30-M

442GA30-M

Internal readers are devices to be positio-ned inside the premises to be managed to allow actuation of room loads and services only in presence of an enabled card. Such readers are capable of operating even wi-thout requiring other devices of the same hotel series.

MIFARE technology allows generating cards having higher security level and integrating advanced services (e-money) therein with topmost level reading performance. Furthermore, they are capable of commu-nicating with other devices such as room control unit, external reader, environment thermostat and MIFARE card programmer. The readers are provided with two auxiliary inputs for detecting the state of dry con-tacts (voltage free concon-tacts) and with four output relays (still dry contact).

Electrical features

With DC power supply

• Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 80mA • Maximum absorption (@ +12Vdc): _ 150mA With AC power supply

• Supply voltage: 12Vac ±30%

• Allowed supply frequency: 50 ÷ 60Hz •Stand-by absorption (@ 12Vac):_ 200mArms •Maximum absorption (@ 12Vac):

_ 250mArms

A2:2007

• LVD 2006/95/EEC. According to EN 60950-1:2006 harmonised standards:

Auxiliary relay outputs

• Maximum applicable load (resistive A.C.):

5A @ 250Vac (cosϕ 1)

• Maximum applicable load (CC): 5A @ 30Vdc

• Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4) • Duration of contact (electric): 50.000 manoeuvres maximum load) • Maximum switching (electric) frequency: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) frequency

18.000 cycles/hr.

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 9 mm (from plate wire)

• Active area lighting: by means of low-absorp-tion high-efficiency blue LEDs

• Degree of protection: IP 40

• Terminal boards: 2 + 2 + 10 poles 12A - 250V

• Programming connector: Female Stereo Jack d=2.5mm

• Blue light for identification in the dark

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C • Maximum relative humidity: 90% @ +35°C • Maximum altitude: 2000m a.s.l.

MIFARE technology

• Means: ISO7816 (Credit Card format) • Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard)

Compliance with standards

• R&TTE 1999/5/EC Directive – Made of class 1. According to ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards

• EMC Directive 2004/108/EC.

According to the following harmonised stan-dards:

- ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 +

DESCRIPTION OF TERMINAL BOARD

OVERALL DIMENSIONS

67,5 mm

55,5 mm

45 mm

441GA30-M

Cod. Description Modules

441GA30-M Internal reader with pocket - MIFARE 3 Domus 100 series

442GA30-M Internal reader with pocket - MIFARE 3 3 Life44 series

External reader (room)

Terminal Colour Description

A Green “A” RS-485

B Green “B” RS-485

- Black - Supply (Common inputs) + Black + Supply

1 Green Room Light Input 2 Green Window Contact Input 3 e 4 Green Room Light Output

5 Green Common for Terminals 6, 7 and 8 6 Green Air Conditioner Enabling Input 7 Green Load Control Output (FEM) 8 Green “DO NOT DISTURB” Output

Stand-alone system with

(16)

30

31

Card programmer

Card

Cod. Description Moduli

SCR-ALBM1

44339CHM-M

44339CHU-M

Item SCR-ALBM1 is a MIFARE card pro-grammer capable of communicating with the hotel series devices. SCR-ALBM1 is provided with a USB interface (compatible with 1.1 and 2.0 USB specifications), which allows directly interfacing the pro-grammer to a monitoring PC for program-ming cards and/or for monitoring and/or programming all MIFARE hotel manage-ment devices.

In order for item SCR-ALBM1 to operate, it is required to be connected to a PC provi-ded with a special card programming sof-tware supplied as a kit. There are two types of software: the first basic one intended for the end user and a more technical one meant for installers and/or technical assi-stance centres

Light signals (LEDs)

• L1 (Red): NOT EXEC

Indicates that the last command sent has not executed correctly.

• L2 (Green): EXECUTED

Indicates that the last command sent has been executed correctly

• L3 (Yellow): WAIT

Indicates that the programmer is free and ready to receive new commands (blinking) or that it is completing the execution of a

MIFARE cards used for hotel management are provided with a rewritable memory equivalent to 1kb.

44339CHM-M Card master

The system is conceived to use a Master card in order to be able to perform any card preparation and/or programming opera-tion. This Master card has its own unambi-guous code called “Hotel Code” which is transferred to the reader through the same Master in the direct programming step alongside any other required data and a

Mechanical features

• Container: 123 l x 30 h x 68 p mm • Material: ABS (UL 94 HB)

• Colour: Black (Ral 9005) • Degree of protection: IP40 • PC interface: USB 1.1/2.0 (Type B connector)

• ARMBus interface: Stereo Jack 2.5mm

Operating mode

The SCR-ALBM1 transponder card pro-grammer may be used as a simple device for programming cards used for MIFARE hotel management, both in stand-alone and in network mode or in combination with a further software (meant for techni-cians and/or installers), as a programmer for all modules made for hotel manage-ment. As a matter of fact, it allows upda-ting management firmware and/or modi-fying configuration parameters (resident in EEPROM) of the various devices of the MIFARE hotel series.

Furthermore, it allows monitoring traffic both on the room Bus (Sniffer) bearing all the messages and/or commands circula-ting in the Bus itself.

sonnel card programming step, it is tran-sferred on all the programmed cards through the reader itself. In case of failure or absence of SCR-ALBM1 programmer, all the access card programming opera-tions may be performed by using the Ma-ster card, following procedures outlined in the reader instructions.

44339CHU-M User card

User cards allow access to or use of a service. These cards are of the following types: CLIENT, ROOM SERVICE PER-SONNEL, MAINTENANCE PERPER-SONNEL, PASSEPARTOUT, SUPER-GUEST, SUB-MASTER, MASTER COPY, ERASER previous command (fixed light).

• L4 (Yellow): TX

Indicates that a communication from the SCR-ALBM1 programmer to the PC through interface is in progress

• L5 (Yellow): RX

Indicates that a communication from the PC to the SCR-ALBM1 programmer throu-gh interface is in progress.

Electrical features

• Supply voltage (DC):

+5Vdc ±10% self supplied through USB port

• Stand-by absorption (@ +5Vdc): _ 50mA

• Maximum absorption (@ +5Vdc): _ 100mA

• USB interface compatibility: USB1.1/2.0

Climatic conditions

• Temperatura ed umidità relativa di riferimento: 25°C – UR 65% • Range operativo di temperatura: 0°C ÷ +40°C

• Umidità Relativa massima: 90% @ +35°C

• Altitudine massima: 2000m s.l.m.

“Progressive Room Code” automatically increased by the reader after the first con-figuration.

Systems divided into several zones and/or several sub-systems may be built. In this case, the system must be provided with a Master card for each of the predetermined combinations (e.g. 3 zones and 2 sub-systems = 6 Master cards). NOTE: The Master card (or Master cards) serves as an identification for the system and it should be preserved with care for possible future configurations.

The system code received by the Master card (alongside the sub-system code and zone code), is memorised by the reader and, during the client and/or service

per-SCR-ALBM1

44339CHM-M

44339CHU-M

SCR-ALBM1 MIFARE card programmer -SFW-ALB04 software included

SFW-ALB04 Card generation software

Generates a 125kHz or MIFARE card depending -on the programmer used

SFW-ALBTEC System configuration software for technicians and installers

-Notes : - the encoder and MIFARE cards operate both in stand-alone systems and in network modes

-for further details on SFW-ALB04 software see page 25

44339CHM-M MIFARE Master Card Card format: ISO7816

44339CHU-M MIFARE User Card

-Card format: ISO7816

Cod. Description Modules

Stand-alone system with

(17)

32

33

Thermostat

Cod. Description Modules

441GA52-T

442GA52-T

The thermostat is used for detecting environ-ment temperature and manageenviron-ment of the ther-moregulation of a hotel room or other premises in general. The thermostat is capable of inde-pendently managing its inputs and outputs. Furthermore, the thermostat is capable of com-municating with the other devices such as the room control centre, external reader, internal reader and card – both 125kHz and MIFARE – programmer.

This device is provided with two live analogue auxiliary inputs (+5Vdc) for detecting resistive values (room/window status and water tempe-rature) and with four dry contact relay outputs. In addition, it is capable of managing both hea-ters and fan-coils.

Electrical features

With DC power supply

• Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 50mA • Maximum absorption (@ +12Vdc): _ 150mA With AC power supply

• Supply voltage: 12Vac ±30% • Allowed supply frequency: 50 ÷ 60Hz • Stand-by absorption (@ 12Vac): _ 75mArms • Maximum absorption (@ 12Vac):

_ 200mArms

Compliance with standards

• IEC/EN 60730-1: automatic electrical con-trols for household and similar use (Part 1 - ge-neral requirements)

• IEC EN 60730-2-9: automatic electrical con-trols for household and similar use (Part 2-9 - Particular requirements for control devices sen-sitive to temperature)

Auxiliary relay output

• Maximum applicable load (resistive): 2A @ 250Vac (cosϕ 1)

• Maximum applicable load (inductive): 2A @ 250Vac (cosϕ 0.4)

• Duration of contact (electric): 50.000 manoeuvres maximum load)

• Maximum switching (electrical) frequen-cy: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching

(mechanical) frequency: 18.000 cycles/ hr.

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 6.5 mm

(from plate wire)

• Degree of protection: IP40

• Terminal boards: 2+2+10 poles 12A - 250V

• Programming connector: Female stereo jack d=2.5mm • Compatible with all Sistema 44 elements.

Temperature detection

• Measurement range: from 0°C to 40°C • Regulation range: 30°C (from 5°C to 35°C) • Reproducibility error: 0.2°C (max)

• Consistency: 0.3°C (max)

• Thermostat differential: from 0.2°C to 0.2°C to 2.5°C adjustable

• Display in °C or °F

441GA52-T

442GA52-T

441GA52-T Saving thermostat with fan-coil or heaters regulation

for stand-alone hotel management system 3 - Domus 100 series

442GA52-T Saving thermostat with fan-coil or heaters regulation

for stand-alone hotel management system 3 - Life44 series

Note: by connecting the 53GA91-T temperature probe to the thermostat, you obtain the automatic summer/winter switching

DESCRIPTION OF TERMINAL BOARD

DESCRIPTION OF THE BUTTON PANEL DESCRIPTION OF DISPLAY

ANTIFREEZE:

antifreeze function enabled (valve open and fan speed 1)

WINTER:

winter mode. If blinking it means the window is open

ARMBUS ADDRESS:

used only during programming step

OVERTEMPERATURE:

overtemperature control enabled

TEMPERATURE MEASUREMENT UNIT:

°C = degrees Celsius °F = degrees Fahrenheit °E = temperature out of range

INTERMEDIATE :

mild season mode. If blinking it me-ans the window is open

BUS:

system connected to Bus

OFF” REGULATION:

thermoregulation disabled ma-nually. Antifreeze and overtempe-rature functions remain enabled

SAVING MODE:

foperating time controller by exter-nal clock

KEY LOCK ENABLED

FAN COIL:

air conditioner enabled (fan symbol). The vertical bar indica-tes the fan-coil speed.

NIGHT SAVING:

thermostat in night saving mode

SUMMER:

thermostat in summer mode. If blinking it means the window is open

ANTIFREEZE:

antifreeze control enabled

Enables/disables environment thermoregulation

Decreasing the temperature set-point by 0.1°C steps

Increasing the temperature set-point by 0.1°C steps

Regulates the fan-coil speed

Stand-alone system 125kHz

and MIFARE technology

common products

Stand-alone system 125kHz

and MIFARE technology

common products

Terminal Colour Description

A Green “A” RS-485

B Green “B” RS-485

- Black - Supply (Common inputs) + Black + Supply

1 Green Window Contact/Room status Input 2 Green Water Probe Input

3 e 4 Green Valve Output

5 Green Common for Terminals 6, 7 and 8 6 Green Fan Coil Speed 1 Output 7 Green Fan Coil Speed 2 Output 8 Green Fan Coil Speed 3 Output

(18)

34

35

Room Control Unit

Cod. Description Modules

53GA72-T

Article 53GA72-T is a room control unit to com-plete the transponder stand-alone hotel array of products. 53GA72-T is capable of independen-tly managing its outputs and inputs as well com-municating with various slave devices of the same hotel series (external reader, internal rea-der and environment thermostat) or with a pos-sible master device (monitoring PC connected to the Bus through the ALB04 or SCR-ALBM1 programmer.

The 53GA72-T room control unit is provided with four auxiliary inlets for detecting the state of the dry contacts and the four relay outputs. It is provided with an internal clock (RTC or REAL TIME CLOCK) with lithium buffer battery which allows complete management of a clock/calen-dar required in case one wants to use the expi-ry function of the cards and/or the night saving function of the thermostat.

The control unit has two LEDs at the front. The LEDs indicate the following:

LED green (BATT): supply status of the device. If “ON” with fixed light it indicates that all is OK.

Mechanical features

• Container: 4 S44 modules (69.5 l x 89.5 h x 65 p) mm • Degree of protection: IP40

• Terminal boards: 10 poles + 8 poles 12A - 250V

• Programming connector: Female stereo jack d=2.5mm

Compliance with standards

• EMC Directive 2004/108/EC.

In compliance with the following harmoni-sed standards

- EN 50090-2-2:1996 + A1:2002 + A2:2007

• LVD 2006/95/EEC. In compliance with the EN 60950-1:2006 harmonised stan-dards

Electrical features

With DC power supply • Supply voltage: +12Vdc ±25% • Stand-by absorption (@ +12Vdc): _ 75mA • Maximum absorption (@ +12Vdc): _ 200mA

With AC power supply • Supply voltage: 12Vac ±30%

• Allowed supply frequency: 50 ÷ 60Hz

• Stand-by absorption (@ 12Vac): _ 150mArms

• Maximum absorption (@ 12Vac): _ 300mArms

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l

53GA72-T

53GA72-T Room control unit for stand-alone systems 4 DIN

GA-RTC Portable device for setting date and time

-TERMINAL BOARD

OVERALL DIMENSIONS

69,5 mm

65 mm

89,5 mm

Terminal Colour Description

1 Green Supply

2 Green A” RS-485

3 Green “B” RS-485

4 Green + Supply

5 Green AveBus +

6 Green Electric Lock Input 7 Green Room Light 2 Input 8 Green “DO NOT DISTURB” Input 9 Green Air Conditioner 2 Enabling Input 10 Green Common Inputs and AVEBus (GND) 11 e 12 Green Electric Lock Switch Output

13 Green Room Light 2 Switch Output 14 Green Loads (FEM) 2 Switch Output

15 Green Air Conditioner 2 Enabling Switch Output NC contact 16 Green Air Conditioner 2 Enabling Switch Output NO contact 17 Green Common for Terminals 13, 14, 15 and 16

Stand-alone system 125kHz

and MIFARE technology

common products

Stand-alone system 125kHz

and MIFARE technology

(19)

36

37

Network hotel

(20)

38

39

Cod. Description Modules

441AR01-M External reader – MIFARE 3 Domus 100 series

442AR01-M External reader – MIFARE 3 Life44 series

442AR02-M External reader AVETouch – MIFARE 3 AVETouch series

External reader

441AR01-M

442AR01-M

The external readers in network are devices which, by means of MIFARE card, allow controlling access to rooms and hotel premises. External readers are capable of communicating with the room control unit, and they are driven by the latter through a monitoring cen-tral station.

Such readers are provided with two auxiliary inputs for detecting the status of the dry contacts (voltage free) and four relay inputs (still dry contact). External readers are provided with a non-volatile memory for personalising some operating parameters (e.g. du-ration of the electric locking com-mand).

Electrical features

With DC power supply • Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 80mA • Maximum absorption (@ +12Vdc): _ 150mA With AC power supply

• Supply voltage: 12Vac ±30%

• Allowed supply frequency: 50 ÷ 60Hz

• Stand-by absorption (@ 12Vac):

Compliance with standards

• R&TTE 1999/5/EC Directive – Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards • EMC Directive 2004/108/EC.

In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007

• LVD 2006/95/EEC. In compliance with the EN 60950-1:2006 harmonised standards.

Auxiliary relay outputs

• Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1)

• Maximum applicable load (CC): 5A @ 30Vdc

• Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4)

• Duration of contact (electric): 50.000 manoeuvres maximum load) • Maximum switching (electric) frequency: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) frequency 18.000 cycles/hr.

_ 200mArms

• Maximum absorption (@ 12Vac): _ 250mArms

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 9 mm (from plate wire) for the Domus 100 and Life44 series, while the AveTouch 442GA02-M code is beneath the components wire.

• Active area lighting: by means of high-efficien-cy blue LEDs

• Degree of protection: IP 40

• Terminal boards: 2 + 2 + 10 poles 12A - 250V

• Programming connector: Female Stereo Jack d=2.5mm

• Compatible with all Sistema 44 elements

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

MIFARE technology

• Means: ISO7816 (Credit card format) • Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard)

Terminal Colour Description

A Green Pole “A” Line RS-485 B Green Pole “B” Line RS-485

- Black Negative Supply (Common Inputs) + Black Positive Supply

1 Green Input (e.g. Room status detection) 2 Green Input (e.g. Courtesy Light) 3 e 4 Green Output (e.g. Courtesy Light)

5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Electric lock) 7 Green Output (e.g. Bell) 8 Green Output (e.g. “Guest In”)

DESCRIPTION OF TERMINAL BOARD

OVERALL DIMENSIONS

67,5 mm

55,5 mm

45 mm

Network system with

MIFARE technology

Network system with

MIFARE technology

441AR01-M

442AR02-M Application examples Available upon request

442AR01-M

(21)

40

41

Cod. Description Modules

442AR30-M

441AR30-M Internal reader with pocket - MIFARE 3 Domus 100 series

442AR30-M Internal reader with pocket – MIFARE 3 Life44 series

Internal reader (room)

441AR30-M

442AR30-M

Internal readers in network are devices to be positioned inside the premises to be managed to allow actuation of room loads and services only in presence of an enabled card. External readers are capable of communicating with the ro-om control unit, and they are driven by the latter through a monitoring central station.

Such readers are provided with two auxiliary inputs for detecting the status of the dry contacts (voltage free) and four relay inputs (still dry contact).

Electrical features

With DC power supply • Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 80mA • Maximum absorption (@ +12Vdc): _ 150mA

With AC power supply

• Supply voltage: 12Vac ±30% • Allowed supply frequency: 50 ÷ 60Hz

• Stand-by absorption (@ 12Vac): _ 200mArms

• Maximum absorption (@ 12Vac): _ 250mArms - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007

• LVD 2006/95/EEC. In compliance with EN 60950-1:2006 harmonised standards

Auxiliary relay outputs

• Maximum applicable load (resistive A.C.):

5A @ 250Vac (cosϕ 1)

• Maximum applicable load (CC): 5A @ 30Vdc

• Maximum applicable load (inductive A.C.):

3A @ 250Vac (cosϕ 0.4) • Duration of contact (electric): 50.000 manoeuvres maximum load) • Maximum switching (electric) frequency: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) frequency

18.000 cycles/hr.

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 9 mm

(from plate wire)

• Active area lighting: by means of high-efficien-cy blue LEDs

• Degree of protection: IP 40

• Terminal boards: 2 + 2 + 10 poles 12A -250V

• Programming connector: Female Jack Ste-reo d=2.5mm

• Compatible with all Sistema 44 elements

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l. MIFARE technology

• Means: ISO7816 (Credit card format) • Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard)

Compliance with standards

• R&TTE 1999/5/EC Directive – Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards • EMC Directive 2004/108/EC.

In compliance with the following harmonised standards: DESCRIZIONE MORSETTIERA OVERALL DIMENSIONS

67,5 mm

55,5 mm

45 mm

441AR30-M

Terminal Colour Description

A Green Pole “A” Line RS-485 B Green Pole “B” Line RS-485

- Black Negative Supply (Common Inputs) + Black Positive Supply

1 Green Input (e.g. Room status detection) 2 Green Input (e.g. Courtesy Light) 3 e 4 Green Output (e.g. Courtesy Light)

5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Electric lock) 7 Green Output (e.g. Bell) 8 Green Output (e.g. “Guest In”)

Network system with

(22)

42

43

Termostat

Cod. Description Modules

441AR52-M

442AR52-M

The thermostat is used for detecting environment temperature and mana-gement of the thermoregulation of a hotel room or other premises in gene-ral. The thermostat is capable of com-municating with the room control unit, and it is driven by the latter through the monitoring central station, hence allowing remote control of the tempe-rature.

This device is provided with two live analogue auxiliary inputs (+5Vdc) for detecting resistive values (room/win-dow status and water temperature) and with four dry contact relay ou-tputs.

Electrical features

With DC power supply • Supply voltage: +12Vdc ±25%

• Stand-by absorption (@ +12Vdc): _ 50mA • Maximum absorption (@ +12Vdc): _ 150mA With AC power supply

• Supply voltage: 12Vac ±30%

• Consistency: 0.3°C (max)

• Thermostat differential: from 0.2°C to 0.2°C to 2.5°C adjustable

• Display in °C or °F

Compliance with standards

• IEC/EN 60730-1: automatic electrical con-trols for household and similar use (Part 1 - ge-neral requirements)

• IEC EN 60730-2-9: automatic electrical con-trols for household and similar use (Part 2-9 Particular requirements for control devices sen-sitive to temperature)

Auxiliary relay output

• Maximum applicable load (resistive): 2A @ 250Vac (cosϕ 1)

• Maximum applicable load (inductive): 2A @ 250Vac (cosϕ 0.4)

• Duration of contact (electric): 50.000 manoeuvres maximum load)

• Maximum switching (electrical) frequen-cy: 1200 cycles/hr

• Duration of contact (mechanical): 5.000.000 manoeuvres

• Maximum switching (mechanical) frequency: 18.000 cycles/hr. • Allowed supply frequency:

50 ÷ 60Hz

• Stand-by absorption (@ 12Vac): _ 75mArms

• Maximum absorption (@ 12Vac): _ 200mArms

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

Mechanical features

• Container: 3 S44 modules (67.5 l x 45 h x 55.5 p) mm

• Max extension from components wire: 6.5 mm (from plate wire)

• Degree of protection: IP40

• Terminal boards: 2+2+10 poles 12A - 250V • Programming connector:

Female stereo jack d=2.5mm

• Compatible with all Sistema 44 elements

Temperature detection

• Measurement range: from 0°C to 40°C • Regulation range: 30°C (from 5°C to 35°C) • Reproducibility error: 0.2°C (max)

441AR52-M

442AR52-M

441AR52-M Saving thermostat with fan-coil or heaters 3 regulation for network hotel management system -

Domus 100 series

442AR52-M Saving thermostat with fan-coil or heaters 3 regulation for network hotel management system -

Life44 series

Nota: by connecting the 53GA91-T temperature probe to the thermostat, you obtain the automatic summer/winter switching

DESCRIPTION OF TERMINAL BOARD

DESCRIPTION OF THE BUTTON PANEL DESCRIPTION OF DISPLAY

Enables/disables environment thermoregulation

Decreasing the temperature set-point by 0.1°C steps

Increasing the temperature set-point by 0.1°C steps

Regulates the fan-coil speed

ANTIFREEZE: antifreeze fun-ction enabled (valve open and fan speed 1)

WINTER: rwinter mode. If blinking it means the win-dow is open

ARMBUS ADDRESS:

used only during programming step

OVERTEMPERATURE:

overtemperature control enabled

TEMPERATURE MEASURE-MENT UNIT:

°C = degrees Celsius °F = degrees Fahrenheit °E = temperature out of range

INTERMEDIATE :

mild season mode.

If blinking it means the window is open

BUS:

system connected to Bus

“OFF” REGULATION: ther-moregulation disabled manually. Antifreeze and overtemperature functions remain enabled

SAVING MODE: operating time controller by external clock

KEY LOCK ENABLED

FAN COIL: air conditioner ena-bled (fan symbol).

The vertical bar indicates the fan-coil speed.

NIGHT SAVING:

thermostat in night saving mode

SUMMER:

thermostat in summer mode. If blinking it means the window is open

ANTIFREEZE:

antifreeze control enabled

Network system with

MIFARE technology

Network system with

MIFARE technology

Terminal Colour Description

A Green Pole “A” Line RS-485 B Green Pole “B” Line RS-485

- Black Negative Supply (Common Inputs) + Black Positive Supply

1 Green Input (e.g. Window/Room Status) 2 Green Input (e.g. Water Probe)

3 e 4 Green Output 1 (e.g. Valve)

5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Fan Coil Speed 1) 7 Green Output (e.g. Fan Coil Speed 2) 8 Green Output (e.g. Fan Coil Speed 3)

(23)

44

45

SCR-ALBM1

SCR-ALBM1 MIFARE Card programmer SFW-ALB04 software included

SFW-ALB04 Card generation software Generates a

125kHz or MIFARE card depending on the programmer used

SFW-ALBTEC system configuration software for technicians and installers

Note: - MIFARE reader and cards operate both on stand-alone and network

modes

- for further details on SFW-ALB04 software see page 25

- for further information on the programmer and cards see page 30

Cod. Description Modules

Hotel Control Unit

53AR01-485

53AR02-485

Item 53AR01-485 is the room control unit for managing access (reservation/check-in/ check-out), all functions regarding thermore-gulation, alarm management, flow manage-ment alongside all functions aimed at energy saving. Besides managing all room functionali-ties, 53AR01-485 is capable of communica-ting with the room devices (readers, thermo-stats, transmitters and receivers for actuating loads) and interfacing the room with the moni-toring system server.

Item 53AR02-485 is the control unit meant for managing common areas (e.g. corridors) in-cluding the functions regarding thermoregula-tion, alarm management and all functions ai-med at saving energy.

Furthermore, this control unit also manages access to zones, by means of readers to be used as common access points. In addition it allows interfacing the zones with the monito-ring system server.

Climatic conditions

• Reference relative temperature and humidity: 25°C – RH 65%

• Operating temperature range: 0°C ÷ +40°C

• Maximum relative humidity: 90% @ +35°C

• Maximum altitude: 2000m a.s.l.

Mechanical features

• Container: DIN Bar 6 modules (106 l x 91h x 58,5 p) mm • Degree of protection: IP40 • Terminal boards: 4x 8 poles 12A - 250V

Compliance with standards

• EMC Directive 2004/108/EC. In compliance with EN 50090-2-2:1996 harmonised standards + A1:2002 + A2:2007

• LVD 2006/95/EEC.

In compliance with EN 60950-1:2006 harmonised standards

Electrical features

With DC power supply • Supply voltage: +12Vdc ±25% • Stand-by absorption (@ +12Vdc): _ 150mA • Maximum absorption (@ +12Vdc): _ 400mA

With AC power supply

• Supply voltage: 12Vac ±30%

• Allowed supply frequency: 50 ÷ 60Hz

• Stand-by absorption (@ 12Vac): _ 300mArms

• Maximum absorption (@ 12Vac): _ 600mArms

OVERALL DIMENSION

106 mm

58,5 mm

91 mm

Cod. Description Modules

53AR01-485 53AR02-485

53AR01-485 Hotel control unit - room management version 6 DIN

53AR02-485 Hotel control unit - common area version 6 DIN

Cod. Description Modules

44339CHM-M

44339CHU-M

44339CHM-M MIFARE Master Card - Card format: ISO7816

44339CHU-M MIFARE User Card - Card format: ISO7816

Programmatore di card

Card

Network system with

(24)

46

47

Monitoring the rooms is extremely easy and intuitive. Each room is represented by a card and different colours

instan-tly indicate the status of the room (occupied, vacant, not reserved), while a symbol-based system inside the card pro-vides further detailed information. All the information needed regarding the status of the rooms is found herein wi-thout requiring visualising different screens. In case of several floors, it is possible to move from one floor to another by means of a simple menu bar on the right while the big screen displays a variety of scenes allowing to choose a view having fewer rooms with larger cards and more information or more rooms with smaller cards. Key word: Instantaneous simplicity.

Every room can be monitored independently down to the last detail. The screen dedicated to each room allows controlling each and every component connected to the hotel network and verifying the operating status thereof. Each operating parameter may be modified by the authorised personnel, ranging from the heating/cooling system temperature to the status of the light and rolling shutters up to controlling the opening of the door from the PC. Furthermore, each and every room may have a personalised picture. Are all your hotel rooms different from each other? No need to worry! Each room may have, in its screen, the picture/drawing accu-rately outlining it as it is. Due to the AVE software, personalisation is pushed to the maximum and the facility is entirely under control.

VISTA GENERALE ROOM DETAIL

Cod. Description Modules

SFW-ALB05 Hotel management software: base module

SFW-ALB05-CLI Hotel management software: 5 client licence

SFW-ALB05-FID Hotel management software: hotel management systems interface module

Software

SFW-ALB05

SFW-ALB05-CLI

SFW-ALB05-FID

The AVE hotel management software was conceived to guarantee instant control of the hotels where the Domina Hotel network system is installed. The number of screens to be monitored were reduced to the mi-nimum to make the use of the software easier and quicker. In this manner, also the

newly recruited personnel shall require less training and shall be capable of operating within an extremely short period of time. Domina Hotel AVE software helps you ke-ep everything under control.

Network system with

(25)

48

49

Network systems and

stand-alone common components

Accessori

5349 442076 441070/1 442070B/2 442070W/2 441086 442086 WIRING DIAGRAMS

Cod. Description Modules Cod. Description Modules

5349 12V transformer 4DIN

53GA91-T NTC probe for thermostats

-GADS01 Silencer device for AC electric locks

-442076 Casting signalling light (external doorframe) with red

diffuser – for lamps with E10 10x28 mm 230V~ 3W 2 max coupling

441070/1 Step-marker lamp - 12-24 VDC/ AC or 230Vac power 1 Supply - high efficiency white LED - Domus 100 series

442070B/2 Step-marker lamp - 12-24 Vdc/ac or 230V power 2 supply - high efficiency blue LED - Life 44 series

442070W/2 Step-marker lamp - 12-24 Vdc/ac or 230V power 2 supply - high efficiency white LED - Life44 series

441086 Portable extractable anti black-out lamp - Complete with recharge base - Complete with rechargeable and replaceable batteries - Lamp: high efficiency white LED 2 - Front switch for switching “OFF” in case of mains power failure - Recharge time: 12 hours - Life: 2 hours - 230 Vac power

supply - Domus 100 series

442086 Portable extractable anti black-out lamp - complete with recharge base - complete with rechargeable and replaceable batteries - lamp: high efficiency white LED - Front switch 2 for switching “OFF” in case of mains power failure - Recharge

time: 12 hours - Life: 2 hours - 230 Vac power supply - Life44 series

GADS01 5349

Nota: in the Life44 and Domus100 civil series (in the respective catalogues) there are more than 200 functions and different standard sockets, entirely matching at technical and aesthetic level with the proposals illustrated in this catalogue.

Electric lock

Red/Black

(26)

50

51

Codes summary

DEVICES

ARRAY External reader Internal reader Thermostat Control unit Encoder Card

125kHz stand-alone 441GA01-T (Domus100) 442GA01-T (Life44) 441GA30-T (Domus100) 442GA30-T (Life44) 441GA52-T (Domus100) 442GA52-T (Life44) 53GA72-T SCR-ALB04 44339CHM-T (MASTER) 44339CHU-T ((USER) MIFARE stand-alone 441GA01-M (Domus100) 442GA01-M (Life44) 442GA02-M (AveTouch) 441GA30-M (Domus100) 442GA30-M (Life44) SCR-ALBM1 44339CHM-M (MASTER) 44339CHU-M ((USER) MIFARE In network 441AR01-M (Domus100) 442AR01-M (Life44) 442AR02-M (AveTouch) 441AR30-M (Domus100) 442AR30-M (Life44) 441AR52-M (Domus100) 442AR52-M (Life44) 53AR01-M (Room) 53AR02-M (Common areas)

References

Related documents

The message passing algo- rithm performs better than Algorithm C in recovering the labels of a graph with a single community with outliers, as each vertex takes into account

Contemplative beach Punta Madruguilla cove (200m long), with a walkway leading to the main hotel swimming pool and La Caracola pool bar located opposite the hotel

It is likely that the factors that make firms different – in our argument an adaptation capability to different foreign business environments - underlie a

detectors). Systems supplied to the U.S. domestic markets include a factory supplied PC including a Microsoft Windows operating system, Vista 2000 control software, a laser printer,

(iv) While ORANGE Air Cargo will endeavor to exercise its best efforts to provide an expeditious delivery in accordance with regular delivery schedules; however ORANGE Air Cargo

Results suggest that the probability of under-educated employment is higher among low skilled recent migrants and that the over-education risk is higher among high skilled

common school philosophy; Horace Mann; school choice; education vouchers; conservatism; public good; charter schools; accountability; individualism; libertarianism;

More worrisome is the possibility of non-random migration, which is not a real concern with our mortality results (given we measure outcomes at ages 5-9, just a few years after