• No results found

Technical Data FLIR A310

N/A
N/A
Protected

Academic year: 2021

Share "Technical Data FLIR A310"

Copied!
11
0
0

Loading.... (view fulltext now)

Full text

(1)

Technical Data

FLIR A310

Part number:

48201-1101

Copyright

© 2013, FLIR Systems, Inc.

All rights reserved worldwide. Names and marks appearing herein are either registered trademarks or trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are used for identification only and are the property of their respective owners.

September 20, 2013, 05:27 AM

Corporate Headquarters

FLIR Systems, Inc. 27700 SW Parkway Ave. Wilsonville, OR 97070 USA

Imaging and optical data

Telephone: +1-503-498-3547

IR resolution 320 × 240 pixels

Website

http://www.flir.com Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK

Customer support Field of view (FOV) / Minimum focus distance 25° × 18.8° / 0.4 m (1.31 ft.)

http://support.flir.com

Focal length 18 mm (0.7 in.)

Legal disclaimer

Spatial resolution (IFOV) 1.36 mrad

Specifications subject to change without further notice.

Lens identification Automatic

Camera models and accessories subject to regional market considerations. License procedures may apply.

F-number 1.3

Information and equipment described herein may

Image frequency 30 Hz

require US Government authorization for export purposes. Diversion contrary to US law is prohibited.

Focus Automatic or manual (built in motor)

Zoom 1–8× continuous, digital, interpolating zooming on images

Detector data

Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–13 µm

Detector pitch 25 µm

Detector time constant Typical 12 ms

Measurement

Object temperature range –20 to +120°C (–4 to +248°F)

0 to +350°C (+32 to +662°F)

Accuracy ±2°C (±3.6°F) or ±2% of reading

Measurement analysis

Spotmeter 10

Area 10 boxes with max./min./average/position

Isotherm 1 with above/below/interval

Measurement option Measurement Mask Filter

Schedule response: File sending (ftp), email (SMTP) Difference temperature Delta temperature between measurement functions or

refer-ence temperature

Reference temperature Manually set or captured from any measurement function Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric

temperature and relative humidity

Optics transmission correction Automatic, based on signals from internal sensors

Emissivity correction Variable from 0.01 to 1.0

Reflected apparent temperature correction Automatic, based on input of reflected temperature External optics/windows correction Automatic, based on input of optics/window transmission

and temperature

Measurement corrections Global and individual object parameters

Alarm

Alarm functions 6 automatic alarms on any selected measurement function,

Digital In, Camera temperature, timer

Page 1 (of 4) http://www.flir.com

48201-1101_en_50.xml,

ver.

(2)

FLIR A310

Alarm

P/N: 48201-1101

Alarm output Digital Out, log, store image, file sending (ftp), email

© 2013, FLIR Systems, Inc.

(SMTP), notification All rights reserved worldwide.

Set-up

Color palettes Color palettes (BW, BW inv, Iron, Rain)

Set-up commands Date/time, Temperature°C/°F

Storage of images

Storage media Built-in memory for image storage

File formats Standard JPEG, 16-bit measurement data included

Ethernet

Ethernet Control, result and image

Ethernet, type 100 Mbps

Ethernet, standard IEEE 802.3

Ethernet, connector type RJ-45

Ethernet, communication TCP/IP socket-based FLIR proprietary

Ethernet, video streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Ethernet, image streaming 16-bit 320 × 240 pixels @ 7-8 Hz

- Radiometric

Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0

Ethernet, protocols Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP,

HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP

Digital input/output

Digital input, purpose Image tag (start/stop/general), Input ext. device (program-matically read)

Digital input 2 opto-isolated, 10–30 VDC

Digital output, purpose As function of ALARM, Output to ext. device (programmati-cally set)

Digital output 2 opto-isolated, 10–30 VDC, max 100 mA

Digital I/O, isolation voltage 500 VRMS

Digital I/O, supply voltage 12/24 VDC, max 200 mA

Digital I/O, connector type 6-pole jackable screw terminal

Composite video

Video out Composite video output, PAL and NTSC compatible

Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)

Power system

External power operation 12/24 VDC, 24 W absolute max

External power, connector type 2-pole jackable screw terminal

Voltage Allowed range 10–30 VDC

Environmental data

Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40°C to +70°C (–40°F to +158°F)

Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)

EMC • EN 61000-6-2:2001 (Immunity)

• EN 61000-6-3:2001 (Emission) • FCC 47 CFR Part 15 Class B (Emission)

Encapsulation IP 40 (IEC 60529)

Bump 25 g (IEC 60068-2-29)

Vibration 2 g (IEC 60068-2-6)

Page 2 (of 4) http://www.flir.com

48201-1101_en_50.xml,

ver.

(3)

FLIR A310

Physical data

P/N: 48201-1101

Weight 0.7 kg (1.54 lb.)

© 2013, FLIR Systems, Inc. All rights reserved worldwide.

Camera size (L × W × H) 170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)

Tripod mounting UNC ¼"-20 (on three sides)

Base mounting 2 × M4 thread mounting holes (on three sides)

Housing material Aluminum

Shipping information

• Infrared camera with lens • Calibration certificate • Cardboard box • Downloads brochure • Ethernet™ cable • FLIR apps card • FLIR Tools download card • Getting Started Guide • Important Information Guide • Mains cable

• Optics brochure • Power cable, pig-tailed • Power supply

• Service & training brochure • Thank you card

• User documentation CD-ROM • Utility CD-ROM

• Registration card

Page 3 (of 4) http://www.flir.com

48201-1101_en_50.xml,

ver.

(4)

70mm

2,76in

70mm

2,76in

33,3mm

1,31in

35mm

1,38in

33,3mm

(2x)

1,31in

2,9mm

0,11in

32,7mm (3x)

1,29in

182mm

7,16in

172mm

6,76in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

35mm

1,38in

M4 (6x)

UNC 1/4-20 (3x)

Camera with built-in IR lens f=18 mm (25°)

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

1(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(5)

172mm

6,76in

264,4mm

10,41in

85,4mm

3,36in

68mm

2,68in

33,3mm

(2x)

1,31in

Lens support

Optional

82,5mm

3,25in

33,3mm

1,31in

70mm

2,76in

41,3mm

1,62in

118,1mm

4,65in

41,3mm

1,62in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

M4 (6x)

UNC 1/4"-20 (3x)

3,55in

90,1mm

For additional dimensions see page 1

Camera with Lens IR f=4 mm (90°) incl support

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

2(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(6)

70mm

2,76in

33,3mm

1,31in

70mm

2,76in

35mm

1,38in

213mm

8,37in

34mm

1,33in

47mm

1,85in

33,3mm

(2x)

1,31in

171mm

6,75in

35mm

1,38in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

66,4mm

2,62in

M4 (6x)

UNC 1/4"-20 (3x)

1,51in

38,4mm

For additional dimensions see page 1

Camera with Lens IR f=10 mm (45°)

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

3(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(7)

20mm

0,77in

199mm

7,82in

58mm

2,28in

33,3mm

(2x)

1,31in

171mm

6,75in

33,3mm

1,31in

70mm

2,76in

70mm

2,76in

35mm

1,38in

35mm

1,38in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

52,3mm (3x)

2,06in

M4 (6x)

UNC 1/4"-20 (3x)

0,95in

24,3mm

Camera with Lens IR f=30 mm (15°)

For additional dimensions see page 1

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

4(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(8)

172mm

6,76in

280mm

11,03in

101,1mm

3,98in

109mm

4,29in

48mm

(2x)

1,89in

33,3mm

(2x)

1,31in

96mm

3,78in

Lens support

Optional

Base support

Optional

108,5mm

4,27in

48mm

1,89in

8mm

0,31in

70mm

2,76in

54,3mm

2,14in

35mm

1,38in

45mm

±0,1

1,77in

±0,00

54,3mm

2,14in

88,5mm

3,48in

54,5mm

2,15in

90mm

±0,1

3,54in

±0,00

UNC 1/4"-20 (5x)

4,17in

105,8mm

For additional dimensions see page 1

Camera with Lens IR f=76 mm (6°) incl support

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

5(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(9)

162mm

6,38in

341mm

13,43in

172mm

6,76in

68mm

2,68in

33,3mm

(2x)

1,31in

Lens support

Optional

82,5mm

3,25in

41,3mm

1,62in

33,3mm

1,31in

70mm

2,76in

55mm

2,17in

41,3mm

1,62in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

194,8mm

7,67in

M4 (6x)

UNC 1/4"-20 (3x)

WD = 21mm

0,83in

Object plane

6,56in

166,8mm

For additional dimensions see page 1

Camera with Close-up lens 1X (25 µm) incl support

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

6(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(10)

172mm

6,76in

30,5mm

1,2in

209,5mm

8,25in

55mm

2,17in

33,3mm

(2x)

1,31in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

M4 (6x)

UNC 1/4"-20 (3x)

35mm

1,38in

63,2mm (3x)

2,49in

WD = 33mm mm

1,3in

Object plane

33,3mm

1,31in

70mm

2,76in

35mm

1,38in

70mm

2,76in

1,39in

35,2mm

For additional dimensions see page 1

Camera with Close-up lens 2X (50 µm)

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

7(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

(11)

172mm

6,76in

30,5mm

1,2in

55mm

2,17in

209,5mm

8,25in

33,3mm

(2x)

1,31in

70mm

2,76in

33,3mm

1,31in

70mm

2,76in

35mm

1,38in

12mm

(3x)

0,47in

24mm

(3x)

0,94in

35mm

1,38in

63,2mm (3x)

2,49in

M4 (6x)

UNC 1/4"-20 (3x)

WD = 79mm mm

3,11in

Object plane

1,39in

35,2mm

For additional dimensions see page 1

Camera with Close-up lens 4X (100 µm)

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

A

B

C

D

E

F

G

H

F

C

E

G

D

A

B

-Scale

1:1

A

Size Modified

R&D Thermography

2012-04-18

CAHA

Basic dimensions FLIR A3xx/SC3xx

T125002

8(8)

A3

Denomination Drawn by Check Size Drawing No. Sheet

7

References

Related documents

Low-risk foods (jams, jellies, baked goods, etc) are exempt from the Georgia Food Act when they are sold directly to consumers at small farmers markets or festivals sponsored by city,

In comparison with the cumulative successful rates of maxillary and mandibular implants in Buser et al.’s (1997), respectively, 87.2% and 95.6%, the cumulative successful rate

“I think the college experience shapes people in so many ways, and I think it’s important that people know a little bit at least about the school that they attend outside of

Specifications where the dependent variable is time for child rearing and time for housework include: individual fixed effects, family type fixed effects, year fixed effects,

Tuition and fee information can be found in “Tuition and Fees” section of the catalog. Modular programs are offered throughout the year on a schedule independent of the

We pro- vide a complete analysis of the regularized model, e.g., existence of a global minimizer, invariance property, support recovery, and properties of block

Psychiatric and metabolic evaluations were performed weekly during inpatient, then monthly using the following instruments: depression (Montgomery-Asberg Rating Scale), mania

sustainability: analyses of pharmacy costs, revenues and profit shed light on retail medicine mark-ups in rural Kyrgyzstan BMC Health Services Research