Model DE-3 Air Release Head

N/A
N/A
Protected

Academic year: 2021

Share "Model DE-3 Air Release Head"

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

SMITH METER® AIR ELIMINATOR

The Smith Meter® Model DE-3 Air Release Heads are an electric float switch devices for installation on a model AR or VAR air eliminator tanks. They are intended to be used in metering systems where air entrapped in the product is particularly troublesome (e.g., pumping off tank trucks and barges).

The triple float switch air release head provides a unique method of air elimination designed to function in an unloading or Petro-gard II system. The elimination of air from liquid product is essential for accurate metering. The DE-3 is used in conjunction with the AccuLoad® Preset controller that operates the control valve, air eliminator solenoid and pumps. With the probability of a large slug of air at the beginning and end of the batch, and possible entrapped air during the batch, the opera-tion of the air release head funcopera-tions to remove the air as it accumulates in the tank. The three float switches suspended at different levels in the tank sense the level of fluid and perform the appropriate functions as programmed in the AccuLoad.

FEATURES

» Efficient Air Elimination – Performs under a wide range of operating conditions.

» Hazardous Areas – Suitable for use in NEC Class I, Division 1, Group D¹.

PRINCIPLE OF OPERATION

2

Maximum Flow Rate

Smith Meter Model DE-3 Air Release Head is designed to be used in conjunction with a Petro-gard II unload-ing system interfaced to an AccuLoad. The three float switches on the DE-3 assembly are configured as Stop

SPECIFICATIONS

MEASUREMENT SOLUTIONS

We put you first.

And keep you ahead.

(lower switch), Low (middle switch) and High (top switch) flow digital inputs in the AccuLoad to define when to open the flow control valve, when to advance from the low flow rate to high flow rate and when to close the valve in the unloading system.

When the batch is started, the main pump is turned on and product begins to fill the system and the AccuLoad moni-tors the Stop float switch. The control valve remains closed to allow the air vent solenoid to vent the initial slug of air from the tank.

The vented air should be plumbed to a low pressure point in a safe location such as a tank or sump. The location must be considered as vapors will vent and accumulate. If the vent solenoid should fail in sealing, there is also the possibility of fluid accumulation in the vent line. A sight glass is incorporated in the DE-3 vent plumbing to verify that the product is not bypassing the meter. When the Stop float switch is activated, the control valve is opened and low flow is initiated as programmed in the AccuLoad. An optional zero flow timer can be programmed into the Ac-cuLoad. If this option is not used, as the fluid level rises in the tank, the zero flow timer counts down. If the Stop float switch is not activated by the incoming fluid within the countdown timer, the batch is stopped.

Model DE-3 Air Release Head

Bulletin SS03037 Issue/Rev. 0.2 (10/15)

1 Since power must be present at the reed switches in the float stem within the vessel, damage to the stem could cause a short circuit. Danger of an explosion is eliminated by the use of safety barriers, which limit the current below the level where incendiary sparking can occur.

2 The principle of operation described is only one of the possible sequences of operation available with the AccuLoad.

(2)

As the tank fills with product and air is vented through the air vent solenoid, the middle and upper float switches are monitored. Once the middle and the upper float switches are activated, the AccuLoad will initiate the high flow rate programmed in the AccuLoad. If during the batch entrapped air in the fluid accumulates in the tank so that the fluid level drops below the upper and the middle float switches, the low flow rate will remain until the air is vent-ed and the middle and the upper float switches are raisvent-ed. At this time, the high flow will be returned to resume de-livery of the batch.

At the end of the batch, the fluid level in the tank will lower as air enters the tank. As the air accumulates, the upper and the middle floats will drop initiating low flow. The delivery will continue at low flow until the fluid level in the tank drops to the lower float switch. When the lower float drops, the AccuLoad will close the flow control valve and turn off the main pump.

*Reference AB06055 for optional gear pump operation and product

detection using Boolean equations in the AccuLoad.

SPECIFICATIONS

Viscosity

DE-3: Up to 45 mPa•s3 (200 SSU)

VDE-3: Up to 19.8 mPa•s3 (100 SSU)

Consult factory for higher viscosities. Recommended Product Specific Gravity DE-3: 0.65 or greater

VDE-3: 0.40 or greater Pressure Rating

150 psi (1,034 kPa) maximum working pressure with standard solenoid

Temperature Range

-10°F to 225°F (-12°C to 107°C) For other temperatures, consult factory Power Requirements

Voltage:

Standard: 120 VAC +0% - 15%, 50/60 Hz Optional: 240 VAC +0% - 15%, 50/60 Hz For other voltages, consult factory. Weight

DE-3: 20 lb (9.1 kg) VDE-3: 53 lb (24.0 kg)

MATERIALS OF CONSTRUCTION (WETTED PARTS)

Model Type Float Assembly Mounting Plate Tubing and Fittings/ Pilot Valves Solenoid Valves4 Sight Glass

DE-3 Standard 316 S.S. Carbon Steel Carbon Steel/VitonLow Swell Buna 300/400 S.S./Viton/Low Swell Buna Brass

VDE-3 Standard 316 S.S. Carbon Steel Carbon Steel/Viton 300/400 S.S./Viton Stainless Steel

450 400 350 300 250 200 150 100 50 0 0 20 40 60 80 100 120 140

Pressure Differential Across Vent Line (psig)

Ve nt Ra te Stan da rd Ft /M in . ( scf m) 3 Standard DE-3 High Capacity DE-3 Standard VDE-3 40 35 30 25 20 15 10 5 0 0 20 40 60 80 100 120 140

Pressure Differential Across Vent Line (psig)

Ve nt Ra te Ac tu al Ft /M in . ( acf m) 3 Standard DE-3 High Capacity DE-3 Standard VDE-3

AIR VENT RATE

3 1,000 mPa•s = 1,000cP = 1 Pa•s. 4 Consult factory for alternate materials.

(3)

DE-3 for Horizontal AR Tank

MODELING CODE

5 Polytetrafluoroethylene (PTFE)

Example

Type Plate Float Volt / Solenoid Special

DE-3 C 5 6

Strainer Type

Code Description

DE-3 Triple Float Configuration

Mounting Plate / Material

Code Description

C Standard Smith Meter/"RB" Bolt Circle/Carbon Steel

CF Standard Smith Meter/"RB" Bolt Circle/Carbon Steel/FIC-3

AC 3" 150 ASME Flange/ Carbon Steel

Float Assembly

Code Description

3 PTFE5 Floats with 316 Stainless Steel Stem - Used for model AR-3-1030

4 PTFE5 Floats with 316 Stainless Steel Stem - Used for model AR-4-2040

6 PTFE5 Floats with 316 Stainless Steel Stem - Used for model AR-6-3050

7 PTFE5 Floats with 316 Stainless Steel Stem - Used for model AR-6-4565 and AR-8-45100

Voltage / Solenoid (All Stainless Steel)

Code Description

6 120/60 Viton-F Stainless Steel

7 240/60 Viton-F Stainless Steel

8 120/60 Viton-F H-coil Stainless Steel

9 110/50 Viton-F Stainless Steel

10 220/50 Viton-F Stainless Steel

11 120/60 Chemraz H-coil Stainless Steel

12 110/120 Viton-A High Capacity Stainless Steel

Special

Code Description

0 Nothing Special

T Tee Vent Plumbing

HC High Capacity Plumbing

(4)

VDE-3 for Vertical VAR Tank

MODELING CODE

Example

Type Plate Float Volt / Solenoid

VDE-3 CC 1 1

Strainer Type

Code Description

VDE-3 Triple Float Configuration

Mounting Plate / Material

Code Description

CC 6" 150 ASME Flange/Carbon Steel/FIC-3

Float Assembly

Code Description

1 PTFE5 float s.g. 0.45/316 Stainless Steel Stem

2 316 Stainless Steel float s.g. 0.40/316 Stainless Steel Stem

Voltage / Solenoid (All Stainless Steel)

Code Description

1 110/120 Viton-A Stainless Steel

2 220/240 Viton-A Stainless Steel

(5)

Figure 1 – Smith Meter Model DE-3 with Model AR Air Eliminator Tank

Figure 2 – Smith Meter Model VDE-3 with Model VAR Air Eliminator Tank

Plug Mounting Plate AR Tank Air Vent Solenoid (N.C) J. Box w/Relay, Current Limited Barrier Sight Glass 10B Check Valve 03A Ball Valve Customer Supplied Input Power To AccuLoad® To Meter Flame Check* Lower Middle Upper Float Switch Assembly Supply Mounting Plate Plug Air Vent Solenoid (N.C) J. Box w/Relay, Current Limited Barrier Sight Glass 10B Check Valve 03A Ball Valve Customer Supplied Input Power VAR Tank Lower Middle Supply Upper Float Switch Assembly To Meter To AccuLoad®

*Can be connected to Vapor Recovery

*Can be connected to Vapor Recovery

(6)

www.fmctechnologies.com/measurementsolutions

© 2015 FMC Technologies. All rights reserved. SS03037 Issue/Rev. 0.2 (10/15)

FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100

Houston, Texas 77067 USA P:+1 281.260.2190

USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101 304.0

We put you first.

And keep you ahead.

Revisions included in SS03037 Issue/Rev. 0.2 (10/15):

Changed sight glass material to brass. Remove PWHT from special option. Correct mounting plate on Figure 2. Remove #7 from Model Code DE-3 Horizontal AR Tank Float Assembely Chart. Updated modeling code for DE-3 for horizontal AR tank. Replaced photo.

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the “Contact Us” link in the left-hand column.

7.0 (177.8) Conduit Connection 0.500 - (14) NPT 7.0 (177.8) 10.06 (255.5) 3.50 (88.9) 7.37 (187.5) 2.25 (57.2) 17.50 (444.5) Approx. 5.25 (133.4) 6.00 (152.4) Solenoid Sight Glass CheckValve ValveBall k

Flame Chec Barrier

Approx. 18.75

(476) for 4" Air Eliminator 15.75

(400) for 3" Air Eliminator 38.25

(971.5) for Vertical Eliminator

7.0 (177.8) Conduit Connection 0.500 - (14) NPT 7.0 (177.8) 10.06 (255.5) 3.50 (88.9) 7.37 (187.5) 2.25 (57.2) 17.50 (444.5) Approx. 5.25 (133.4) 6.00 (152.4) Solenoid Sight Glass

Check Valve Ball Valve k Flame Chec Barrier Approx. 18.75

(476) for 4" Air Eliminator 15.75

(400) for 3" Air Eliminator 38.25

(971.5) for Vertical Eliminator

DIMENSIONS (DE-3)

Inches (Millimeters)

References

Related documents

If water runs into the flush tank continuously, check the inlet valve washer, tank stopper ball, and the outlet valve seat.. Adjust the float arm to

Ultra Filtration Cartridge Rinse Ball Valve (Manual) Carbon Element Housing System Flush Solenoid Valve (Automatic) Inlet Ball Valve (Manual) Outlet Ball Valve (Manual) Check

hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; damping for the switching output / analog output; display can be rotated

And the last classification of assault class, those that were committed within the family, by peers and other groups and these are sexual and verbal abuse.. Can you give examples

Pete; though the number of firms with paid workers is still tiny, data suggest strong revenue & job growth over the past 5 years.. Black-Owned Businesses in

Collectively, these best practices span the continuum of care and leverage critical communication tactics that will help provider organizations comply with CMS guidelines;

Company Wrench offers high reach and long reach excavators, material handling equipment, skid steers, mini excavators, wheel loaders, crushers, and screeners, as well as a full

[r]