PRODUCT OF ECH ELEKTROCHEMIE HALLE GmbH – GERMANY

Aqua

max KF Plus Coulometric

(in-lab ppm water determination)

The Aquamax KF Plus titrator are conform of standards for water determination: DIN 51777, ASTM D 1364, ASTM D 1533, ASTM D 4377, ASTM D 6304, ASTM E 203, IP 356, IP 471, ISO 10336, ISO 6296

The Aquamax KF Plus is a truly versatile Coulometric Karl Fischer Titrator featuring a robust measuring vessel design and ‘press go’ key pad.

The device is used to determine trace level water content in a liquid sample. The Aquamax KF Plus is suitable for a wide range of applications with sample dosing directly into the measuring cell Applications : Hydrocarbons, Lubricating oils, Motor oils, Hydraulic oils, Insulating oils, Transfomer oils, Mineral oils, Crude oils, Petroleum products, Fuels, Bunker fuels, Jet fuels, Diesel, Bio fuels, Ionic liquids, Organic liques, Solvents

Aqua

max KF Portable Coulometric

(on-site ppm water determination in oil and fuels)

Measuring and controlling the amount of water in oils is of considerable economic importance to the industrial community, particularly to the crude oil and electric power industries. Water content determination by Karl Fischer titrator is no longer restricted to being used by a chemist in a laboratory – now the technique

is used by engineers, plant operators, tanker drivers, distribution/maintenance engineers and other non-laboratory personnel.

Karl Fischer titrator can now be performed in many different locations such as the tailgate of trucks, mobile laboratories offshore installations, tankers, engineering workshop and dockside cabins.

The Aquamax KF Portable is a truly mobile version of the very successful Aquamax KF Coulometer wich includes Low Drift Cell twin port glassware as standard. Also incorporates a carry handle and a protective sleeve for the titration vessel and electrodes. The unique low drift cell glassware design is by far the easiest to use and also the most robust. The electrode locking system allows the joints to seal completely, without the use of grease or PTFE sleeves, and provides improved baseline stability. Hassle free assembly and disassembly. This glassware enables users to transport the instrument with reagents already in the titration cell so that it can be used immediately on arrival.

(3)

PRODUCT OF ECH ELEKTROCHEMIE HALLE GmbH – GERMANY

Aqua

max KF Reagent Kit

Aquamax KF Reagent A is a general coulometric KF anolyte for use with generator electrodes which incorporate a frit or diaphgram to separate the anode and cathode chambers. Used in conjunction with Reagent C this formulation is supplied in a pack of 8x100mL bottles, 8x5mL cathode vials, all conveniently located in a single carton.

To conform to ASTM, API, EI, ISO (plus others) methodology for water content determination of oil and petroleum products, the anode reagent must be modified with xylene to improve sample solubility and miscibility. Aquamax KF Reagent is pre-mixed with xylene, and other solubilizers to eliminate side reactions, so that the operator does not have to store or mix chemicals.

Range of ECH 7000 Volumetric Titrator

KF Volumetric Titrator

With the KF Titrator you can determine the water content of liquids very easily. The device is based on volumetric titration according to the Karl Fischer method. The KF Titrator works fast and precise for a wide range of use.

The actual curve and the measurement drift during titration process appear in the display and you can see the titration solvent consumption. Standard methods for different application are programmed.

The titration is performed automatically until the endpoint indication of measurement. At the end of the measurement, result are shown in ppm water of several other units.

Measurement Method: Volumetric titration

Types of result: ppm or mg/l or using the formulation generator Measuring range: 10 ppm … 100%

(4)

PRODUCT OF ECH ELEKTROCHEMIE HALLE GmbH – GERMANY

Alkalinity Titrator

The Alkalinity Titrator is suitable for determination of carbonate and bicarbonate hardness of water samples. The alkalinity of natural waters is primary caused by hydroxyl ions in free state and the salt of carbonate and bicarbonate along with borates, silicates and phosphates.

The measurement uses volumetric titration method with sulphuric acid or hydrochloric acid (0.01 – 0.1 mol/L)

The titration is performed automatically until the endpoint indication of

measurement. At the end of the measurement, results are shown in mg/L CaCO3 or mmol/L ˚dH (degrees of German hardness) or several other units.

Applications : Alkalinity values are the basis for correct dosage of chemicals for treatment of water and wastewater. The instrument is suitable for analysis of drinking water, surface water, seawater, technical waters, boiler water, cooling water

Measurement method: Volumetric titration

Types of result: p value mmol/L CaCO3= German hardness degree (˚dH) m value mmol/L, formula generator avalible

Measuring range: pH 1 … 14

mV -2000 … 2000

Resolution of the display: pH 0.001 mV 0.1

TAN/TBN Titrator

The TAN/TBN Titrator is suitable for determination of Total Acid Number (TAN) or Total Base Number (TBN) of oils and fats. The acid number expresses the quantity of base required to neutralize all acidic constituents of the sample. It is a quality feature for freshness of oils and fats. The base number indicates the quantity of acid which can be neutralized by additives in mineral oils.

The device is conform to standards IEC 62021-1, ISO 3771, ASTM D 664, ASTM D 2896, ASTM D 4739. The measurement uses a potentiometric titrator method in an anhydrous medium. The titration with titrant starts, once the oil sample is does into the reagent. The user has to enter the sample weight into the menu, the titration speed is precisely adjusted to the reaction rate by control algorithms.

The titration is performed automatically until the endpoint indication is measurement. At the end measurement, result are showing in mg KOH/g oil or several other units.

Application : transformer oils, natural and artificial fats, mineral oil products, lubricants, food fats (e.g.olive oil, butter)

Measurement method: Volumetric titration

Types of result: mg KOH/g oil or using the formula generator Measuring range: 0.01 … 250 mg KOH/g oil

(5)

PRODUCT OF ECH ELEKTROCHEMIE HALLE GmbH – GERMANY

H2S MercaptanTitrator

The Sulfur Titrator is designed for the determination of sulfur compounds as hydrogen sulfide and mercaptan sulfur in liquid hydrocarbons and oils. The measurement uses a volumetric titration method with silver nitrate solution in an anhydours medium.

This measurement generates silver sulfide (Ag2S) and silver mercaptides. The analysis must be done in an insert gas atmosphere to void an oxidation of sulfur compounds by air and thus false measurement result.

The device is conform to standards ISO 3012, ASTM D 3227, UOP 163, UOP

212.

The titration speed is precisely adjusted to the reaction rate with control algorithms. Two end point get indicated – first for hydrogen sulfide and second for mercaptan sulfur. At the and of the measurement, result are shown in mg/kg (ppm) hydrogen sulfide and/or mercaptan sulfur or several other units.

Applications : fuels (gasoline, kerosines, aviation turbine fuels), volatile distillates, middle distillates, liquified petroleum gas (LPG), hydrocarbon gases, liquid hydrocarbons, naphtha (petroleum), low boiling oils, light cycle oils, heavy cycle oils

Measurement method: Volumetric titration

Types of result: mg/kg (ppm) hydrogen sulfide and/or mercaptan sulfur, formula generator available Measuring range: Hydrogen sulfide/sulfide: less than 1 to several thousand mass-ppm

Mercaptan sulfur: 3 – 500 mass-ppm typically Resolution of the display: 0.01 ppm

Bromine Titrator

The value of Bromine Number expresses the trace amount of unsaturated constituents of hydrocarbons and oils. It is determined by measuring of consumed bromine for cleavage of double or multiple bounds during the titration. The value are needed for determination of parameters for further processing of petroleum products.

The device is conform of standard ASTM D 11159, ASTM D 2710 and ASTM D 5776. The titration is performed authomatically until the endpoint indication of measurement. At the end of the measurement, results are shown in mg Br2/100 g (Bromine Index) or g Br2/100 g (Bromine Number).

Aplications : petroleum distillates, gasoline (including leaded, unleaded, oxygenated fuels), kerosene, distillates in the gas oil range, commercial propylene trimer and tetramer, butane dimer, mixed nonenes, octenes, heptanes, olefinfree hydrocarbons or mixtures.

(6)

PRODUCT OF FORZA INTERNATIONAL – USA

OIL & PETROLEUM TESTING

FORZA MODEL HTKV-D445-L-7

High-Temperature Kinematic Viscosity Bath with Windows-based touch panel

Features:

Windows-based, High-Resolution 7" Touch Panel with Integrated

Timers.

Fully ASTM D445 Compliant software.

Digital microprocessor precise temperature control with an accuracy

of +/- 0.01°C.

Viscometer Tracking by Serial Number.

Viscometer Calibration Constant Database.

Geographic adjustment for Standard Gravity: pre-loaded with user’s

local std.gravity.

Option to Run or Ignore, Dual Viscometer Runs.

Easy to Export Data to USB, or other Data Processing Software.

Built-in safety features for over temperature and Low liquid level

conditions.

Thermally Insulated, High-Vis Front Glass Window, Integrated

backlight.

Bath volume: Approx.18 liters.

Minimum temperature: 30°C.

Maximum temperature: 150°C.

7 Viscometer positions.

FORZA MODEL RUST-D665-L-M-TP SERIES MANUAL RUST BATHS

Features:

Fully conforms to ASTM D665, NACE TM-01-72, IP 135

Reduces Operator Errors and Improved Precision

Liquid Bath(-L) or Optional Liquid Free Bath(-TH)

Operation Parameters Adjustable via Color Touch Panel

Stirrers Agitating at Precisely 1000 rpm, ±0 rpm

Stirrers Adjustable from 0 to 1100 rpm

Temperature Range ambient to 80°C

(7)

PRODUCT OF FORZA INTERNATIONAL – USA

OIL & PETROLEUM TESTING

FORZA Flow Series

:

Cold Properties Manual Dry Bath – Cloud, Pour Point

& CFPP. Fully Conforms to ASTM D97, ASTM D2500 & ASTM D6371

Aluminium Block Bath (Dry Bath).

4 Sample Capacities in each temperature Position.

Temperature Positions available : 0°C, -18°C, -33°C, -51°C and -69°C.

Customized temperature combinations are available on request.

Digital Temperature Controller

CFC Free refrigerant.

Advantages as compared to the liquid bath:

No Toxic Methanol/Ethanol Required.

No stirrer Required.

Very Clean system, No spillage

Longer equipment life than traditional Liquid bath.

No more Float switch failure like liquid bath.

No stirrer failure like liquid bath.

FORZA MODEL FT-D892-A-1 (H/C) FOAMING TENDENCY AIR BATH

Modular One Position System

Test Method:

The ASTM D892 test method covers the determination of the foaming characteristics of

lubricating oils at 24°C and 93.5°C. The test essentially consists of conditioning the

sample at the required temperature and when the sample has reached temperature, air is

blown into the sample at 94 ml/min for 5 minutes. The foam remaining after 10 minutes

from then is recorded. This is indicative of the foaming tendency of the oil. The test is

sequentially done first at 24°C then at 93.5°C and then again at 24°C.

For the ASTM D6082, the procedure is the same except that the test is run only at one

temperature 150°C and the airflow is 200 ml/min.

Advantage of Modular Test Position System : This modular one test position system

offered by Forza enables a client to buy the exact number of positions required. As

demand grows more single modular units may be bought. Further, the units can be set up

to run one temperature and not be heated up or cooled down frequently. This results in an

enormous time-saving. The units may be placed in different parts of the lab to optimize

bench space

(8)

PRODUCT OF FORZA INTERNATIONAL – USA

OIL & PETROLEUM TESTING

FORZA MODEL WS-D1401-L-7

Seven Sample Position Water Separebility Apparatus

Features:

Complies with the requirements of ASTM D1401 and related methods.

Well-lit peripheral visibility bath allowing easy monitoring of emulsion separation status.

Scratch-proof high visibility shield affords protection and prevents temperature upsets.

Operational temperature range of ambient to 90°C.

Bath stability better than +/- 0.2°C.

7 Test positions.

Precision sample stirrer motor for 1500 +/- 1 rpm adjustable up-to 2000 rpm.

Integrated PLC microprocessor-based controller and color touch panel.

Intuitive color touch panel screens display following:

Bath temperature in 0.1°C resolution. Temperature calibrations can be performed in the

calibration screen.

Sample stirrer speed in rpm with 1 rpm resolution.

7 on-screen timers are provided for monitoring status of each sample. These times may

be adjusted in the setup screen.

Stirring time remaining for the test.

Audible alarm on the end of the test.

7 elapsed times for observance of separation.

ASTM D525 : Oxidation Stability of Gasoline (Induction Period Method)

Heated Metal Block – No harmful oils or dangerous steam needed

Highly accurate/precise, microprocessor-based temperature controller with +/- 0.1°C

Built-in data acquisition system-15.6" touchscreen

High-purity stainless steel line oxygen charging unit

DAQ system uses high-performance touch-screen computer with Intel processor

technology

Built-in safety features within the hardware and software

The hardware safety limit for very high temperature

DAQ system can be password protected

Software leak testing password protected

Insulation around and on top of the heated block

Intuitive Software

User – Friendly Layout/ Features – Mimics Heated Block Layout

(9)

PRODUCT OF FORZA INTERNATIONAL – USA

OIL & PETROLEUM TESTING

Automatic Induction Point CalculationDynamic and Static Leak Test (Bypass Available –

Password Protected)

Integrated Database of pressure data points and results

Built-in pressure transducer calibration feature

PDF Report Saving and Printing

ASTM D2274, D943, D2893 : Oxidation Stability

FORZA oxidation instruments come in three types of

baths: heated liquid baths, heated aluminum block baths,

and individually heated tube baths.

Each type of bath has its own advantages.

Heated liquid baths are low cost and considered as the traditional and universally

accepted bath type.

Heated aluminum block baths eliminate the need for expensive and hazardous bath

mediums which benefits laboratory safety, health, environmental, and

maintenance issues.

Individually heated tube baths have all the benefits of aluminum block baths plus

tighter temperature stability and the ability to operate each test position at different

temperatures.

(10)

PRODUCT OF CONSORT - BELGIUM

Portable pH Meter C5000 Series

Specifications depending on model

pH/MV Channels

1

EC/TDS/SAL/DO Channels

1

Temperature Channels

1

pH 0.00 … 14.00pH

mV ±1000 mV

Conductivity 0… 100 mS/cm

0… 1000 mS/cm

Salinity

0.0… 70.0

TDS

0… 100 g/l

Dissolved oxygen

0.00 … 20.00 mg

0… 200%

Temperature

0.0… +100.0˚C

Portable pH Meter C6000 Series

Specifications depending in model

Measurement Channels 1

Temperature Channels 1

pH

-2.000… +16.000 pH

mV

±2000.0 mV

Ion

0.01 ng/I… 100 g/l

Conductivity

0…2000 mS/cm

Resistivity

0…200 MΩ.cm

Salinity

0.0..70.0

TDS

0…100.0 g/f

Dissolved oxygen

0…60.00 mg.l 0…

600%

Air pressure

600…1300 hPa

Temperature

-5.0…+105.0˚C

(11)

PRODUCT OF CONSORT - BELGIUM

Banchtop pH Meter C1000 Series

Specifications depending on model

pH/MV Channels

1

EC/TDS/SAL/DO Channels

1

Temperature Channels

1

pH

0.00…14.00 pH

mV

±1000 mV

Conductivity

0…100 mS/cm

0…1000 mS/cm

Salinity

0.0…70.0

TDS

0…100 g/f

Dissolves oxygen

0.00…20.00 mg

0…20%

Temperature

0.0…+100.0˚C

Banchtop pH Meter C3000 Series

Specifications depending on mode

Measurement Channels 2 to 8 (max 2 EC channels)

Temperature Channels 2 to 6

pH

-10.000…+20.000 pH

mV

±2000.0 mV

Ion

0.01 ng/l…100 g/l

Conductivity

0…2000 mS/cm

Resistivity

0…200 MΩ.cm

Salinity

0.0…70.0

TDS

0…100.0 g/l

Dissolved oxygen

0…60.00 mg/l 0…600%

Air pressure

600…1300 hPa

(12)

PRODUCT OF CONSORT - BELGIUM

Electrodes

pH

Conductivity, EC - ˚C

Ion, ISE

DO –ORP – Glassless pH

Office :

Ruko Freesia Garden No. 12, Jl. Jombang Raya Kav. 148, Bintaro,

Pondok Aren, Tangerang Selatan 15220 INDONESIA

Telp. +62 21 7450367, 22210736, Fax. +62 21 7450367, 73460661

Email: pt.mminstrument@gmail.com