DESIGN OF FOUNDATION F4 UNBRACED BAY
ALLOW.N.S.B.C = 150
ALLOW. N.S.B.C (SEISMIC CASE) = 187.5 = 40
ALLOW. N.S.B.C (WIND CASE) = 187.5 = 460
Unit Weight of Soil = 18 Clear Cover at Top = 75mm
ALLOW. G.S.B.C = 204.0 Clear Cover at Bottom = 75mm
ALLOW. G.S.B.C (SEISMIC CASE) = 241.5 Height of pedestal = 3.45m
ALLOW. G.S.B.C (WIND CASE) = 241.5 Depth of foundation below FGL = 3.00m
Increase in bearing capacity factor for Seis Load = 1.25 Lz = 5.00m
Increase in bearing capacity factor for Wind load = 1.25 Lx = 3.50m
t = 0.50m (Thickness of Footing) P1x = 0.80m P1z = 0.90m X Foundation CG P2x = 0.80m 3.50 Load CG P2z = 0.90m 1.75 FGL Lx = 3.50 0.80 0.80 Z ez 3.00 m 1.75 0.90 0.90 0.50 m 0.75 1.75 1.75 0.75 Lz = 5.00 Self Wt of Footing W1 = 218.75 kN Wt of soil above Fdn W2 = 722.70 kN Wt of pedestal W3 = 106.20 kN Total Wt. = 1047.65 kN
RCC Design (Self Wt. of Footing+Wt. of Surrounding Soil)
Design for 1m width of slab 57.5 KN/m P1 P2
Design for maximum net soil pressure under the footing 0.75 3.50 0.75
Load factor for concrete design = 1.4 Design along longitudinal direction :
Max. Cant Bm at face of column = 16.2x(0.75-0.45)^2/2 0.7 kNm 73.65 KN/m per m run
= 16.2x 3.5 ^2 /8 24.7 kNm 5.00 m Factored Mu (+Ve) = 1.022 kNm Factored Mu (-Ve) = 34.72 kNm Foundation Depth D = 500 mm Effective Depth d = 417 mm Width B = 1000mm kN/m2 kN/m2 Fck N/mm2 kN/m2 F y N/mm2 kN/m3 kN/m2 kN/m2 kN/m2 ex =(L X B-P1x XP1y - P2x X P2y)X(H-t)X18 =P1XXP1ZX(H-t)x25+P2XXP2ZX(H-t)x25
Negative
BM.at Center
Bottom Reinf. Top reinforcement :
% pt pt,prov % pt pt,prov
0.006 0.130 542.1 16 371 150 1340.413 0.32 0.20 0.13 542.1 16 371 150 1340.413 0.32
Max S.F along Z axis =16.2 x (0.75-0.9/2-0.417)x1 = 1.89 kN
Max factored Shear Stress = 0.01 N/mm²
pt, provided = 0.32 %
As per BS 8110-1:1997,Table 3.8 = 0.42 N/mm² OK Design along transverse direction :
Effective Depth d = 403 mm (Self Wt. of Footing+Wt. of Surrounding Soil)
Max BM at face of column =16.2 x (1.75-0.4)^2/2 = 14.7 kNm 57.5 Kn/m per m run
Max Shear at distance d =16.2 x (1.75-0.8/2-0.403)x1 = 15.294 kN 1.75 1.75
Mu/bd2 = 0.127 pt Reinf. = 0.100 Bottom Reinforcement % pt pt,prov 73.65 kN/m per m run 0.127 0.13 523.90 12 216 150 753.9822 0.187 3.50 Top Reinforcement
Provide Minimum Steel = 0.13 x 1000 x 403 /100 = 483.6
Provide 12 mm dia at 150 c/c
753.98 OK
0.187 %
Max factored Shear Stress =15.3x1.4x1000/(1000x403) = 0.05
= 0.36 OK
Refer Table 3.8 BS 8110-1:1997
Check for Punching Shear for U0 :
For Punching Shear Critical Section is considered at '1.5d' from the face of column all around.
Factored vertical load in column = 242 kN
Perimeter of the critical section = 3400 mm
Effective depth = 403 mm
Factored Shear Stress = 0.22 OK
Refer CL 3.7.7.2 BS 8110-1:1997
Check for Punching Shear for U1 :
For Punching Shear Critical Section is considered at '1.5d' from the face of column all around.
Factored vertical load in column = 242 kN
Perimeter of the critical section = 5617 mm
Effective depth = 403 mm
Factored Shear Stress = 0.13
Mu/bd2 Ast,mm2 Dia of
rein bar Reqd. spacing mm spacing provided Ast Pro. mm2 Mu/bd2 Ast,mm2 Dia of rein bar Reqd. spacing mm spacing provided Ast Pro. mm2 Tv=(Vu/bd) N/mm2
Mu/bd2 Ast,mm2 Dia of
rein bar Reqd. spacing mm spacing provided Ast Pro. mm2 mm2/ m run
Astprovided mm2 / m run
(Pt)prov.
N/mm2
Allow. Shear Stress
(T
c)
N/mm2N/mm2 Shear Stress <.8Sqrt(Fck) & 5N/mm2
N/mm2 Corrosponding τ
1.5d
Punching shear perimeter (U1), (Refer figure 3.23, BS-8110:1997)
Punching shear perimeter (U0), (Refer figure 3.23, BS-8110:1997)
20-007-CS-8180-00098 Revision 01Q Annexure - II Design Calculation of Combined Footing CF1 3 of 5
SHELL MARINA LOBP-GMP PROJECT
DESIGN CALCULATION FOR PIPE RACK PR5 - LOBP AREA
DESIGN OF COMBINED FOOTING CF1
ALLOW.GROSS S.B.C
=
200
ALLOW. GROSS S.B.C (WIND CASE)
=
250
=
35
Unit Weight of Concrete
=
25
=
420
Unit Weight of Soil
=
18
Clear Cover at Top
=
50
mm
ALLOW. NET S.B.C
=
160.5
Clear Cover at Bottom
=
75
mm
ALLOW. NET S.B.C (WIND LOAD)
=
210.5
Height of pedestal
=
2.10
m
Depth of foundation below FGL
=
2.00
m
INCREASE IN SBC FACTOR FOR WIND LOAD
=
1.25
Lz
=
6.00
m
Lx
=
2.60
m
t
=
0.50
m (Thickness of Footing)
P1x
=
1.00
m
P1z
=
1.00
m
X
Foundation CG
P2x
=
1.00
m
3.00
Load CG
P2z
=
1.00
m
1.30
FGL
Lx =
2.60
1.00
1.00
Z
ez
2.00 m
1.30
1.00
1.00
0.50
m
1.50
1.50
1.50
1.50
Lz =
6.00
Self Wt of Footing W1
=
195.00 kN
Wt of soil above Fdn W2
=
367.20 kN
Wt of pedestal W3
=
105.00 kN
Total Wt.
=
667.20 kN
kN/m
2kN/m
2F
ckN/mm
2kN/m
2F
yN/mm
2kN/m
3kN/m
2kN/m
2e
x=(L X B-P
1xX
P
1y- P
2xX P
2y)X(H-t)X18
=P1
XXP1
ZXHx25+P2
XXP2
ZXHx25
P1
P2
RCC Design
(Self Wt. of Footing+Wt. of Surrounding Soil)
Design for 1m width of slab
39.5 kN/m
P1
P2
Design for maximum net soil pressure under the footing
1.50
3.00
1.50
Load factor for concrete design
=
1.5
Design along longitudinal direction :
Max. Cant Bm at face of column
=
171.5x(1.5-0.5)^2/2
85.8
kNm
211.00 kN/m per m run
=
171.5x 3 ^2 /8 -171.5x1.5^2/2192.9
kNm
6.00 m
Factored Mu (+Ve)
=
128.625 kNm
Factored Mu (-Ve)
=
289.5 kNm
Foundation Depth D
=
500 mm
Effective Depth d
=
417 mm
Width B
=
1000
mm
K
=
K
=
=
0.02113
=
0.047567
Z=
Min(d((0.5+Sqrt(0.25-K/0.9)),0.95d)
Z=
Min(d((0.5+Sqrt(0.25-K/0.9)),0.95d)
=
396.15 mm
=
393.6534 mm
=
M/0.87fyZ
=
M/0.87fyZ
=
888.581 mm2
=
2012.64
mm2
Mu =
128.625 kNm
Mu =
289.50 kNm
M/fcbd² =
0.021 N/mm²
M/fcbd² =
0.048 N/mm²
pt =
0.130 %
(Refer Table 3.25, SS CP65: Part1: 1999)
pt =
0.130 %
Bottom Reinf.
Top reinforcement :
Mu/fcbd²
Min. % pt
pt,prov
Mu/fcbd² Min % pt
pt,prov
0.021
0.130
888.6
16
226
150
1340.413
0.32
0.05
0.13
2012.6
20
156
150
2094.395
0.5
Max S.F along Z axis
=171.5 x (1.5-1/2-0.417)x1
=
99.98 kN
Max factored Shear Stress
=
0.36 N/mm²
pt, provided
=
0.32 %
For values of τc Refer Table 3.8, SS CP65: Part1: 1999
=
0.53 N/mm²
OK
Negative BM.at Center
M/fcbd
2M/fcbd
2A
sA
sAst,mm
2Dia of
rein bar
Reqd.
spacing
mm
spacing
provided
Ast Pro.
mm
2Ast,mm
2Dia of rein
bar
Reqd.
spacing
mm
spacing
provided
Ast Pro.
mm
220-007-CS-8180-00098 Revision 01Q Annexure - II Design Calculation of Combined Footing CF1 5 of 5