(1)Res. Agr. Eng.. Vol. 59, 2013, No. 3: 105–113. Determination of oxygen permeability of polyethylene and polypropylene nonwoven fabric foils Ľ. Kubík1, S. Zeman2 1. Department of Physics, Faculty of Engineering, Slovak University of Agriculture in Nitra, Nitra, Slovak Republic 2 Department of Production Engineering, Faculty of Engineering, Slovak University of Agriculture in Nitra, Nitra, Slovak Republic Abstract Kubík Ľ., Zeman S., 2013. Determination of oxygen permeability of polyethylene and polypropylene nonwoven fabric foils. Res. Agr. Eng., 59: 105–113. The paper deals with determination of oxygen permeability of the polyethylene and polypropylene foils applied in mulching and food packaging. The construction of the equipment of measurement of gas permeability through the foils is discussed. The design and construction of the equipment was realized with applying of the Standard STN EN 77 0333. The measurement of permeability of oxygen through the polyethylene Bralen 2-63 with 9% colored concentrate Maxithen HP 533041 – violet foil, Polyten®MLB black&white foil and black polypropylene nonwoven fabric foil were realized by means of the modified method. Keywords: gas transmisivity; equipment construction; packaging; mulching. The packaging of foods is very important area of food processing. The mulching of plants is interesting in the agriculture engineering. Materials suitable for food packaging and mulching are applied on the basis of polymers. The protection of original quality of food against external undesirable effects is the function of the packaging materials. Required protection of foods can be achieved with one layer of polymer, or if needed, with multilayer film; it includes different polymers, surface films and metallic foils. Barrier properties, i.e. protection of the package, are related mainly with the ability to transmit the gases and vapours, which are damaging of the quality of the product. Dissipation of the water may cause undesirable drying-out, which shows by the modification of the food structure. Moistening of the food increases the water activity. and the state suitable for expansion of microorganisms is inducing. Božiková (2011) and Božiková and Hlaváč (2011) are interested in thermal characteristic of cheeses, which are very important at food packaging. Degradation processes of foods are also dependent on time and temperature (Pye et al. 1976; Ashley 1985; Jasse et al. 1994). All components of the food have to be taken into account during selection of package materials, as well as the package material, because they can react with one another under the impression of different storage conditions. Oxygen is harmful for foods of vegetal or animal origin. It causes oxidation of higher fatty acids. Internal atmosphere of gases, such as CO2 and N2, is modified of the preservation of the quality of the foods (Jasse et al. 1994). The application of 105.

(2) Vol. 59, 2013, No. 3: 105–113 Res. Agr. Eng. polyethylene plastic foils in horticulture is of great importance; Zeman and Kubík (2007) presented the issue of permeability of polymeric packaging materials and showed the theoretical base of permeability.. Sorption of gases and their transmission through the polymer depends on the permeability and diffusion. The amount of gas Q (mol), which is transferred through the membrane, is defined by the following equation (Jasse et al. 1994): D × σ ( p1 − p2 ) S ×t. h. (1). where: D – coefficient of diffusion (m2/s) p1 – external pressure (Pa) p2 – internal pressure (Pa) h – thickness of membrane (m) s – Henry’s constant (mol/m3.Pa) t – time (s) S – area (m2). On the assumption of thermodynamic equilibrium, the coefficient of permeability P is given by the equation: P = D × s. (2). Permeability is dependent on solubility and diffusivity. These quantities are functions of optional volume, cohesive energy and polymer morphology. The coefficient of permeability is then defined: P=. We can also obtain permeability of the membrane Px (m3/m2.s.Pa) from the equation: Px = P. MATERIAL AND METHODS. Q=. R – universal gas constant, R = 8,314 J/kmol.K T – temperature (K) n – amount of gas (mol). V. Qh. (5). Fick’s second law of diffusion can be obtained by first calculating a conservation equation with respect to volume (Cussler 2003), ⎛ ∂ 2 C h 1 ∂S C h ⎞ ∂C h = D⎜ + (6) ∂t S ∂z ∂z ⎟⎠ ⎝ ∂z 2 where: Ch – molar concentration (mol/m3) z – coordinate (m) t – time (s) D – coefficient of diffusion (m2/s) S – area (m2). By setting S to be constant, Eq. (6) describes unsteady state diffusion, which is Fick’s second law of diffusion. Together, Fick’s first and second laws describe how much solute moves across the film (diffusion flux) and reveal how the solute concentration changes within the film (concentration profile). To apply Fick’s laws, certain assumptions must be made (Fig. 1). Let C1h be the concentration of C10. c10. Qh Qh = S ( p1 − p2 ) t S Δ pt (3). After applying equation of state for ideal gas pV = nRT, we can obtain equation of the coefficient of permeability P (mol/m.s.Pa) suitable for the experimental measurement: Qh pV pV h P= × = S Δ pt n R T t S Δp R T . where: P – permeability (mol/m.s.Pa) Q – amout of gas (mol) S – area (m2) t – time (s) p – pressure (Pa) V – volume of gas (m3). 106. (4). c1h C1h. z h. Fig. 1. Steady-state concentration profile in a thin membrane c10 – partion coefficient (mol/m2); C1h – concentration of downstream solution (mol/m3); h – thickness of membrane (m); z – coordinate (m).

(3) Res. Agr. Eng.. Vol. 59, 2013, No. 3: 105–113. downstream solution and let C10 be the concentration of upstream solution. If H is the partition coefficient which relates pressure in gas to concentration in the film, then c10 = HC10. Initially, the downstream solution is assumed to be free of upstream solution. At time zero, the membrane is also assumed to be free of upstream solution. For t > 0 the amount of upstream solution in the membrane is c10 at z = 0. Furthermore, where z = l the amount of upstream solution is said to be zero. The boundary conditions restrict the downstream solution to be free of the upstream solution. In experiments it was found that the concentration is negligible. These boundary conditions allow Eq. (6) to be transformed into an ordinary differential equation, which will describe a pseudo-steady state in the system. Siegel and Cussler (2004) describe the characteristics of lag time in the diffusion model. After using separation of variables on Fick’s second law and imposing the aforementioned conditions to obtain: ch = ch0 −. ch0 z 2ch0 − h π. ⎛ −D n 2 π 2 t ⎞ ⎛ n π z⎞ sin exp ∑ ⎜⎝ h ⎟⎠ ⎜⎝ h2 ⎟⎠ n=1 ∞. (7). Downstream concetration C/C0. where: ch – concentration on the membrane of thickness h (mol/m2) ch0 – initial concentration on the membrane of thickness h (mol/m2) h – thickness of the membrane (m) z – coordinate (m) D – coefficient of diffusion (m2/s) n – number of nodes (–) t – time (s). ch S D ⎛ h2 ⎞ = t −. ch0 V h ⎜⎝ 6 D ⎟⎠. (8). where: V – ratio of the volume in the air chamber to the area of the fabric ch – concentration on the membrane of thickness h (mol/m2) S – area (m2) D – coefficient of diffusion (m2/s) h – thickness of membrane (m). This limiting equation revealed that there is a lag time for the system to reach the desired pseudosteady state. Namely, the system cannot be described by an ordinary differential equation when t<. h2. 6D. (9). The limiting equation also reveals that the permeability of the membrane can be found experimentally by calculating the best-fit slope of the equation. Similarly the lag time Q (s) can be found by experimentally calculating the x-intercept of the best-fit line of the pseudo-steady state data points (Fig. 2). Then we can obtain the coefficient of diffusion D (m2/s) from the Eq. (8): D=. h2. 6Θ. (10). where: h – thickness of film (m) Q – lag time (s). The solubility coefficient Sp  (mol/m3.Pa) can be calculated using the equation (Pauly 1999): Pseudosteady state. Sp =. P D. (11). where: P – coefficient of permeability P (mol/m.s.Pa) D – diffusion coefficient (m2/s). Lag time. Time. Fig. 2. Typical permeation/lag time curve: normalized downstream concentration versus time in a thin membrane initially free of solute. The code created estimates the pseudo-steady state section (Rutherford, Do 1997). And after calculation of the limit of the above equation at long times:. The solubility coefficient Sp expresses the solubility of oxygen in the foil. Methods of determination of gas permeability are described in Pye et al. (1976), Koros et al. (1992), Jasse et al. (1994) and Sohail (1997). Polymer’s materials present large scale structures and properties which depend on their chemical structure, methods of preparation 107.

(4) Vol. 59, 2013, No. 3: 105–113 Res. Agr. Eng. Fig. 3. Design of equipment of measurement of gas permeability. 1 – upper chamber, 2 – bottom chamber, 3 – membrane of measured material, 4 – ball valve, 5 – needle valve, 6 – oxygen probe, 7 – digital oxygen meter, 8 –pressure control valve, 9 – pressure oxygen cylinder, 10 – one way throttle valve, 11 – manometer, 12 – filter regulator, 13 – air tank, 14 – compressor. and conditions of processing. Significant participation of additives and application of polymer mixtures influence barrier properties of films through CO2, O2, N2, or water vapours (Lee 1980). Design of measurement equipment. Methods of detection and measurement of parameters of packaging materials permeability of gases are specified in the standard STN EN 77 0333 (1987). The method was modified for the conditions of our test. Permeability of the gas was determined at the barrier tests of the materials as one of the specific parameter of the protective efficiency of the packaging. The design of measurement equipment was projected. The design was considered universal for the basic measurements. It represents sufficiently the principles of measurement and corresponds with the standard STN EN 77 0333 (1987). Diagram of design of measurement equipment of gas permeability packaging materials by means of isobaric method is presented in Fig. 3 and equipment is presented in Fig. 4. The bottom chamber was firmly attached on the desk and above it upper chamber was attached by means of nuts. Tested material was inserted between two chambers. Two-part test chamber was made of stainless steel and was thus resistant to corrosion and chemical effects. All parts of the chambers were equipped with the admission valve and the outlet valve and the outlet for the insertion of the oxygen probe. Pressure oxygen cylinder was used as a supply of pure oxygen (99.5%). The amount of oxygen was adjusted by means of the pressure control valve in the upper chamber. The volume of each chamber was 1.128 dm3. Diameter of the effective area between the chambers was 70 mm. 108. Compressor was used to the perfusion of the bottom chamber with the air. Adjusting the air in this branch was integrated by means of the one way throttle valve and the filter regulator. The digital oxygen meters Mesura (Pierron, Sarreguemines, France) were applied for measurement of the amount of diffused oxygen. Basis of the isobaric method test is the determination of the concentration of the testing gas, which diffuses through the tested material from the chamber filled with pure testing gas to the chamber with the air. The pressures of the gases at both chambers are equivalent. The samples have to be planar, pure and without mechanical damage. The samples are conditioned during 24 h in the laboratory conditions. The temperature and the moisture are continually controlled. The dimensions of volumes V1, V2 and S are determined before the test, where V1 is the volume of the upper chamber of the testing vessel measured in m3 with the precision of ± 5%, V2 is the volume of bottom chamber of the testing vessel measured in m3 with the precision of ± 5% and S is the testing area of the sample measured in m2. Procedure of the test. The upper chamber was perfused with the testing gas and the bottom chamber with the air before the measurement as long as the homogenous environs was reached in each of the chambers. The suitable flow of both gases was about 600 cm3/min. The time of the perfusion had to be at least 30 min and it was prolonged if the material was less permeable. The supply of the testing gas was stopped after the perfusion and all valves of both chambers were closed. The time of the permeation of the testing gas through the sample was.

(5) Res. Agr. Eng.. Vol. 59, 2013, No. 3: 105–113 the equation of state for ideal gas the coefficient of permeability P can be obtained from the equation: P=. Δρ p V h 1. Δt S ρi R T. (13). where: ri – density of the gas in the initial volume V (kg/m3) Drp – increase of the density of the gas transferred into calibrated volume V (kg/m3) V – volume of the vessels (m3) h – thickness of the foil (m) S – area (m2) R – universal gas constant 8,314 J/kmol.K T – temperature (K). We can also obtain permeability of the membrane Px (m3/m2.s.Pa) after applying Eqs. (5) and (13) and equation of state for ideal gas pV = nRT, from the equation: Px =. Fig. 4. Equipment of measurement of gas permeability. started in the moment. The diffusion of the gas between both chambers was in the progress for a period of 24 hours. The coefficient of permeability P is determined on the basis of Eq. (4) from the equation: P=. Δp p V h 1. Δt S pi R T. The coefficient of permeability P was obtained from the increase of the concentration Drp (m3/kg) of the gas permeated through the foil to the calibrated volume V in the time Dt because the oxygen probes measured the relative concentration of oxygen and the absolute values of concentration had to be calculated from the tabulated values of the air and oxygen at the real conditions. After applying. Δ t S ρi2 R T. (14). where: M – molecular mass (kg/mol) R – universal gas constant 8314 (J/kmol.K) T – temperature (K) t – time (s) ρp – density of the gas in the calibrated volume V (kg/m3) ρi – density of the gas in the initial volume V (kg/m3). RESULTS AND DISCUSSION. (12). where: pi – pressure of the gas in the initial volume (Pa) V – calibrated volume (m3) h – thickness of the foil (m) Dpp – increase of the pressure of the gas transferred into calibrated volume V (Pa) Dt – time of the duration of the diffusion (day) S – area of the foil (m2) R – universal gas constant, R = 8,314 J/kmol.K T – temperature (K). Δρ p V M. The permeability of pure oxygen (99.5%) through polyethylene and polypropylene foils was studied. Table 1. Conditions of measurement Symbol. Quantity. Description. m. 3. 0.0011283. volume of upper chamber. V2. m. 3. 0.0011283 volume of bottom chamber. ds. m. 0.07. diameter of the foil sample. S. m2. 0.0038465. area of the foil sample. h. mm. 50 and 90. b. Pa. 102 600. T. K. 295. thickness of the foil barometric pressure of the air temperature of the air. j. %. 30. relative moisture of the air. M. kg/kmol. 32. molar mass of the O2. R. J/kmol.K. 8314. universal gas constant. V1. Unit. 109.

(6) Vol. 59, 2013, No. 3: 105–113 Res. Agr. Eng. Table 2. Measured quantities of (A) the PE Bralen 2-63 with 9% coloured concentrate Maxithen HP 533041 – violet foil (thickness 50 mm), (B) PE Polyten®MLB black&white foil (thickness 90 mm) and (C) PP polypropylene nonwoven fabric foil (thickness 50 mm) at the air temperature 295 K Symbol. Unit. Description. Quantity A. Quantity B. Quantity C. Dt. day. r rO. 2. f1O f2O f2O. 1.0000. kg/m. air density. 1.1965. 1.1965. 1.1965. kg/m. 3. O2 density. 1.3386. 1.3386. 1.3386. O2 initial relative concentration, UC 3. kg/m. r2O 120 2 2. DrO100 p 2 100. 1.3118. O2 initial relative concentration, BC 3. 23.0. O2 initial density, BC. %v. 22. 98.0. O2 initial density, UC. %v. 21. FF11O O22 (%) (%). 1.0000. kg/m. 2i. 21. r2O. 1.0382. %v. 2i. r1O. duration of the permeation 3. 0.3079. O2 final relative concentration, BC. kg/m. 3. kg/m. 3. Řady1 23.7 Řady1 Řady2 0.3173 Řady2. O2 final density, BC. 22 – Řady3 1E-05x – 0.0515x 0.0515x 98.436 y =O1E-05x ++ 98.436 density increase in the bottom chamberŘady3 0.0094 2 R² 0.9983 R² == 0.9983 Rad1 violet violet PE PE Rad1. 96.4 1.2904 21.9 0.2620 21.9. 95.7 1.2810 21.0 0.2811 21.9. 0.2620. 0.2932. 0.0000. 0.0121. 80 Rad2 black & &by white PE UC –80 measured by the oxygen probe in the upper chamber; BC –Rad2 measured thePE oxygen probe in the bottom chamber black white Rad3 black black PP PP Rad3 22 – y = 1E-05x – 0.0422x + 93.555 y = 1E-05x 0.0422x + 93.555 Polyethylene samples of foils which contained 91% was made in the company Gabriel-Chemie, Lázně 40 40 R² == 0.9984 0.9984 22 – 2E-05x – 0.055x 0.055x 95.422 polyethylene BralenR² RA 63 andyy 9% coloured conBohdaneč, Czech Republic. Then the polyethyl== 2E-05x ++ 95.422 20 20 R²were 0.9979 == 0.9979 centrate Maxithen HP 533041 – violet,R² used. ene Polyten®MLB black&white foils were stud00 Thickness of the samples was 50 mm. The foils ied, which were made in the company Chemosvit 500 1,000 1,500 00 500 1,000 1,500 were made in the company Slovnaft, a.s., BratisFólie, a.s., Svit, Slovak Republic. The thickness of tt (min) (min) 60 60. the foils was 90 mm. Black polypropylene nonwo-. lava, Slovak Republic and the coloured concentrate. Řady1 Řady1 Řady2 Řady2. 120 120 1E-05x22 –– 0.0515x 0.0515x ++ 98.436 98.436 yy == 1E-05x R² == 0.99834 0.99834 R². fF1F1O (%) O (%) 1O 222 (%). 100 100 80 80 60 60. ◆ Rad2 black & white & white PE PE ■ Black Rad3 black Fig. 5. Dependence of the oxygen ▲ Black PP PP. 1E-05x22 –– 0.0422x 0.0422x ++ 93.555 93.555 yy == 1E-05x. R² == 0.99843 0.99843 R² 2E-05x22 –– 0.055x 0.055x ++ 95.422 95.422 yy == 2E-05x R² == 0.99785 0.99785 R². 40 40 20 20. 00. Řady3 Řady3 Rad1 violet Violet PE PE. 00. 500 500. 1,000 1,000. volume concentration of on the time in the upper chamber during the test. 1,500 1,500. PE – polyethylene foils, PP – polypropylene foil. (min) tt (min). fF2O O (%) F (%) 222(%) 2O. 24.5 24.5 24.0 24.0 23.5 23.5 23.0 23.0. –1E-06x22 ++ 0.0034x 0.0034x ++ 21.17 21.17 yy == –1E-06x R² == 0.99522 0.99522 R². 22.5 22.5 22.0 22.0. 21.5 21.5 21.0 21.0 20.5 20.5. 110. Řady1 Řady1 Řady2 Řady2. -3E-07x22 ++ 0.0009x 0.0009x ++ 22.99 22.99 yy == -3E-07x R² == 0.93504 0.93504 R². ◆ ■ ▲. Řady3 Řady3 Violetviolet PE PE Rad1. Blackblack & white PE PE Rad2 & white Blackblack PP PP Rad3. –5E-06x ++ 21.893 21.893 yy == –5E-06x R² == 0.00161 0.00161 R² 0 0. 500 500. 1,000 1,000 t (min) t (min). 1,500 1,500. 2,000 2,000. Fig. 6. Dependence of the oxygen volume concentration of on the time in the bottom chamber during the test PE – polyethylene foils, PP – polypropylene foil.

(7) (–) 2/F f2FO2O /f O2O21(–) 2 2 21 F2O2/F2O21 (–). Res. 1.07 Agr. Eng.. Vol. 59, 2013, No. 3: 105–113 Řady3. 1.05 1.07. state ▲ yPseudo-steady = 4E-05x + 0.9995. 1.03 1.05. R² = 1 ■ Dependency. y = 4E-05x +y0.9995 = –1E-08x2 + 4E-05x + 0.9995 R² = 1 R² = 0.93504. 1.01 1.03 0.99 1.01 0.97 0.99 0. 0.97. 200. 400. y = –1E-08x2 + 4E-05x + 0.9995 R² = 0.93504 600 800 1,000 1,200 1,400 1,600. Řady2 Fig. 7. Dependence of normalized concentration on the time of the PE Bralen 2-63 pseudo steady Řady3with 9%state colored concentrate Maxithen HP 533041 – violet foil and the tangent of dependency Řady2 pseudo-steady state in the point t = 40 min pseudo steady state. dependency. t (min). 0. 200. 400. 600. 800. 1,000 1,200 1,400 1,600. t (min) 1.32. ◆ Dependency. F2O22/F2O21F (–) f2O222 O (–) O/f 2O22/F 21 2(–)21. 1.27. ■ Pseudo-steady state. 1.22 1.32. 1.17 1.27 1.07 1.17. y = 0.0002x + 1.0083 R² = 1. 1.02 1.12 0.97 1.07. 1.02. 0. 200. 400. Řady2 dependency Řady1 pseudo steady state Řady2. y = 0.0002x + 1.0083 R² = 1. 1.12 1.22. Řady1. y = –5E-08x2 + 0.0002x + 1.0081 R² = 0.99522. dependency. pseudo Fig. steady state 8. Dependence of normalized concentration on the time of the polypropylene nonwoven fabric foil and the tangent of 2 y = –5E-08x + 0.0002x + 1.0081 600 800 1,000 1,200 1,400 1,600 pseudo-steady state in the point t = 60 min R² = 0.99522 t (min). 0.97. 0 foils 200were 400also 600 800 with 1,000 1,600chamber for the Polyten®MLB foils, and an ven fabric realized the1,200 thick-1,400upper ness of 50 mm. The conditions of measurement are increase of the initial values of the oxygen probes t (min) described in the Table 1. The measurements were from 20.9 to 21.0% in the bottom chamber and to realized at the temperature 22°C, 30% air moisture 95.7% in the upper chamber for the polypropylene and the barometric pressure 102,600 Pa. Measured nonwoven fabric foils. Values of the amount of oxyquantities needed of calculating of the result quan- gen in the upper chambers are real, but the values tities are presented in Table 2. The basic absolute in the bottom chambers were occasioned by means values of the volume concentration of oxygen at the of sensibility of the oxygen probe to speed of the air temperature of 295 K were 1.1965 kg/m3 of the air flow and represent the error of the measurement. and 1.3386 kg/m3 of oxygen. These values were calDependencies of the volume concentration of oxyculated and extrapoled by means of the equation gen on the time in the upper chambers during the of state for ideal gas. The absolute values of meas- test are presented in Fig. 5. Dependencies of the volured densities were calculated from the base abso- ume concentration of oxygen on the time in the botlute values and the relative values measured by the tom chambers during the test are presented in Fig. 6. oxygen probes. The oxygen probes were calibrated The dispersion of the curves in Fig. 6 is caused by the on the value of 20.9% of oxygen in the air at the influence on the air perfusion on the beginning of beginning of the test. The perfusion of the equip- the measurement. The coefficients of permeability P ment by the air and oxygen during 30 minutes at were calculated by the Eq. (13). The permeabilities the beginning of the test caused an increase of the of the foils Px were calculated from the Eq. (14). The initial values of the oxygen probes from 20.9 to 23% coefficient of diffusion D of the membrane was dein the bottom chamber and to 98% in the upper termined on the basis of the Eqs (8) and (10). The chamber for the Bralen PE foils, then an increase solubility coefficient Sp of the membrane was deterof the initial values of oxygen probes from 20.9 to mined from the Eq. (11). The measured values from 21.9% in the bottom chamber and to 96.4% in the Tables 1and 2 were used for the calculation.. 111.

(8) Vol. 59, 2013, No. 3: 105–113 Res. Agr. Eng. Table 3. Transport properties of the polyethylene Bralen 2-63 with 9% coloured concentrate Maxithen HP 533041 – violet foil for the oxygen permeability (thickness 50 mm) and black polypropylene nonwoven fabric foil (thickness 50 mm) Bralen 2-63. Black polypropylene. Transport properties. experimental values. experimental values related to the foil thickness. experimental values. experimental values related to the foil thickness. Permeability coefficient (mol/m.s.Pa). 4.7771 × 10–16. 2.3889 × 10–20. 5.7812 × 10–16. 2.8906 × 10–20. 2013.6703. 0.1165. 2822.0832. 0.1633. Diffusion coefficient of (m2/s). 5.8666 × 10–10. 2.9333 × 10–14. 2.9333 × 10–9. 1.4667 × 10–13. Solubility coefficient (mol/m3.Pa). 8.1429 × 10–7. 4.0714 × 10–11. 1.9709 × 10–7. 9.7297 × 10–12. Permeability (cm3/m2.d.0.1MPa). The time lag Q was calculated by performing linear regression analysis on only the data points that contribute to the pseudo-steady state. The model implied the regression should be linear and the general form used was y = b + ax, where a and b were estimated on the basis of the Eq. (8) as it is presented in Fig 2. The tangents in Figs 7 and 8 represent pseudo – steady state of polyethylene Bralen and polypropylene nonwoven fabric foils and their slopes represent the slope of the Eq. (8). Then the diffusion coefficients D were determined: D=. V ×h×a (15) S. where: V – volume (m3) h – thickness of the foil (m) a – slope (1/s) S – area (m2). The dependence of Polyten®MLB foil presented in Fig. 6 is linear and horizontal, so the permeability was minimal and the tangent and the diffusion coefficient D were not possible to determine. The tangents were determined from the analytical equations of the tangent to the curve in the point [xT, yT]: y = k t ( x − xT ) + yT (16) where: kt – f’(xT) y – dependent variable (–) x – independent variable (min) xT – tangent coordinate (min) yT – tangent coordinate (–). The point of the tangent contact was determined in the steepest area. The coordinate of the point 112. in the curve in Fig. 7 was selected as t = 40 min and in Fig. 8 as t = 60 min. Results of the diffusion coefficients and the transport coefficients of oxygen through the PE and PP foils are presented in the Table 3. Transport properties are also related to the thickness of the foil which was 50 mm for polyethylene Bralen 2-63 and the polypropylene nonwoven fabric foil and 90 mm for Polethylene Polyten®MLB black&white foil. The polyethylene Bralen 2-63 with 9% coloured concentrate Maxithen HP 533041 – violet foil and the polypropylene nonwoven fabric foil showed the high values of the coefficients. The foils were highly permeable for oxygen. Bhadha (1999) presented the values of coefficient of permeability P (mol.m/m.s.Pa) in the range from 0.4120 to 0.0375. The foils are not very suitable for the food packaging but they are suitable for mulching of the plants. Polyethylene Polyten®MLB black&white foil showed the null values of the coefficients of the permeability; it was not permeable. The foil is suitable for food packaging and is usually used for packaging of the milk. CONCLUSION The design of the measurement equipment of the oxygen permeability of the packaging and mulching material was realized and the equipment was constructed. The design and the construction of the equipment was realized with applying of the standard STN EN 77 0333. The measurement of the permeability of oxygen through the polyethylene Bralen 2-63 with 9% coloured concentrate Maxithen HP 533041 – violet foil, polyethylene Polyten®MLB black&white foils and black polypropylene nonwoven fabric foil were realized. The measurements and the calculations of the permeability were modified and personal access was ap-.

(9) Res. Agr. Eng.. Vol. 59, 2013, No. 3: 105–113. plied. Modified measurement enabled to obtain the experimental values comparable with other authors. The measurements confirmed that the designed equipment is suitable for measurement of the permeability of oxygen, but the improvement of the gas concentration measurement will be needed for the measurement of absolute concentration of gases. The permeability of oxygen through the polyethylene Bralen 2-63 and the polypropylene nonwoven fabric foils were high. The permeability of oxygen through the polyethylene Polyten®MLB black&white foils was minimal. The polyethylene Bralen 2-63 and the polypropylene nonwoven fabric foils are suitable for mulching technologies. The polyethylene Polyten®MLB black&white foils is suitable for food packaging. References Ashley R.J., 1985. Permeability and Plastics Packaging. London, Elsevier Applied Science Publishers: 383. Bhadha M.P., 1999. How weld hose materials affect shielding gas quality. Welding Journal, 2: 35–40. Božiková M., 2011. Selected thermal characteristics of cheeses. In: PRAE 2011. Nitra, Slovak University of Agriculture: 23–27. Božiková M., HLAVÁČ P., 2011. Effect of temperature on physical properties of selected cheeses. Acta Technologica Agriculturae, 2: 50–54. Jasse B., Seuvre A.M., MathlouthI M., 1994. Permeability and structure in polymeric packaging materials. In: Mathlouthi M. (ed.), Food Packaging and Preservation. New York, Chapman & Hall: 1–21. Cussler E.L., 2003. Diffusion: Mass Transfer in Fluid Systems. 6th Ed. Cambridge, Cambridge University Press: 581.. Koros W.J., Coleman M.R., Walker D.R.B., 1992. Controlled permeability polymer membranes. Annual Review of Materials Research, 22: 47. Lee W.M., 1980. Selection of barrier materials from molecular structure. Polymer Engineering & Science, 20: 65–69. Paul D.R., Kemp D.R., 1973. The diffusion time lag in polymer membranes containing adsorptive filters. Journal of Polymer Science, 41: 79–93. Pauly S., 1999. Permeability and diffusion data. In: Brandrup J., Immergut E.H., Grulke E.A. (eds), Polymer Handbook, 4th Ed. New York, John Wiley & Sons Inc.: 543–569. Pye D.G., Hoen, H.H., Panar M., 1976. Measurement of gas permeability of polymers. Journal of Applied Polymer Science, 20: 287–301. Rutherford S.W., Do D.D., 1997. Review of time lag permeation technique as a method for characterisation of porous media and membranes. Adsorption, 3: 283–312 Siegel R.A., Cussler E.L., 2004. Reactive barrier membranes: some theoretical observations regarding the time lag and breakthrough curves. Journal of Membrane Science, 229: 33–41. STN EN 77 0333, 1987. Determination of gas permeability of packaging materials. Slovak Office of Standards, Metrology and Testing. Sohail H., Jack Y., 1997. ATR-FTIR spectroscopic studies of the structure and permeability of sulfonated poly (ether sulfone) membranes Part 3 – Effects of sorptions and desorption, and of annealin. Journal of the Chemical Society, Faraday Transactions, 93: 1613–1620. Zeman S., Kubík Ľ., 2007. Permeability of Polymeric Packaging Materials. Technical Siences, 10: 26–34. Received for publication May 30, 2012 Accepted after corrections September 11, 2012. Corresponding author:. RNDr. Ľubomír Kubík, PhD., Slovak University of Agriculture in Nitra, Faculty of Engineering, Department of Physics, Tr. A. Hlinku 2, 949 76 Nitra, Slovak Republic phone: +421 37 6414 879, fax.: +421 37 7417 003, e-mail: lubomir.kubik@uniag.sk. 113.

(10)

New documents

Women's retirement : The self in process of transition
Literature on the Self, its ‘properties’, namely self-concept and self-esteem, and ageing, is also presented in this chapter as the present study focuses specifically on the Self in
Bis(1 chloro­methyl­di­aza­bi­cyclo­[2 2 2]­octane κN4)­bis­­(tri­fluoro­pentane 2,4 dionato)copper(II) bis­­(tetra­fluoro­borate)
Data collection: SMART Bruker, 1998; cell re®nement: SMART; data reduction: SAINT-Plus Bruker, 1999; programs used to solve structure: XS in SHELXTL Sheldrick, 1998; programs used to
Aqua­tri­phenyl­(tri­fluoro­acetato)­tin–2,4,6 tris­(2 pyridyl) 1,3,5 triazine (1/1)
structure: SHELXS97 Sheldrick, 1997; programs used to re®ne structure: SHELXL97 Sheldrick, 1997; molecular graphics: ORTEPII Johnson, 1976; software used to prepare material for
μ Ferrio bis­{carbonyl­[μ 2,2′,2′′ nitrilo­tri­ethane­thiol­ato(3 ) N,S,S′,S′′:S,S′]­iron(II)} benzene solvate
Data collection: CAD-4 EXPRESS Enraf±Nonius, 1992; cell re®nement: CAD-4 EXPRESS; data reduction: CAD-4 Processing Program Hursthouse, 1976; programs used to solve structure: SHELXS86
Endogenous fantasy and learning in digital games
Conversely an educational game with exogenous fantasy is defined as: c “one in which the fantasy depends on the skill being learned but not vice versa” and based on the empirical
Bis[di­chloro η6 indaneruthenium(II)] di­chloro­form solvate
Data collection: EXPOSE IPDS Software; Stoe, 2000; cell re®nement: CELL IPDS Software; data reduction: INTEGRATE IPDS Software; programs used to solve structure: SHELXS97 Sheldrick,
Intrinsic fantasy: motivation and affect in educational games made by children
In the current study children were encouraged to create computer games that taught noncurriculum learning content that might be distanced from the extrinsic teaching methods used in
Poly­[[di­aqua(μ4 squarato O,O′,O′′,O′′′)­nickel(II)] 0 71 hydrate]
Data collection: IPDS Program Package Stoe & Cie, 1998; cell re®nement: IPDS Program Package; data reduction: IPDS Program Package; programs used to solve structure: SHELXS97 Sheldrick,
Development of an expert system for reinforced concrete bridge repair
The technique developed achieves compatibility between the repair material and the substrate concrete through a sophisticated balancing of those repair material properties identified as
catena Poly­[μ tri­fluoro­acetato O:O′ di­methyl­phenyl­tin(IV)]
metal-organic papers Data collection: SMART Bruker, 1997; cell re®nement: SAINT Bruker, 1997; data reduction: SAINT; programs used to solve structure: SHELXS97 Sheldrick, 1997; programs

Related documents

Proofs and Concepts: The Fundamentals of Abstract Mathematics
To save space, and make it easier to compare the two, the text will sometimes combine both proofs into one figure, by adding a third column at the right that
0
7
195
The Legal and Ethical Environment of Business
Figure 13.5 The Horizontal and Vertical Nature of Contract Relationships in the Global Legal Environment KEY TAKEAWAYS While international law between sovereign
0
5
421
Government Regulation and the Legal Environment of Business
General exceptions to the jurisdictional immunity of a foreign state a A foreign state shall not be immune from the jurisdiction of courts of the United States or
0
2
900
The Law of Trusts
To address the limits established in sections 3.4 and 4.3 of John's will, Robinson's estate contends in a post-argument brief that “the trust principal need
0
6
396
The Centrality of Style
Table 1: Abbreviated Rubric- Style and Expression Competency Style and Expression Fails to Meet Competency Meets Competency Exceeds Competency F to D C B to A Uses
0
3
379
History in the Making: A History of the People of the United States of America to 1877
Grant defeated Horatio Seymour in the presidential race february 1869 Fifteenth Amendment passed by Congress December 1869 Grant encouraged Congress to readmit
0
14
864
The Little Book of Semaphores
A value of one means that a thread may proceed and access the shared variable; a value of zero means that it has to wait for another thread to release the mutex...
0
1
291
The Power of Selling
Selling U Table of Contents Chapter 1 "The Power to Get What You Want in Life": The Power of Your Personal Brand Chapter 2 "The Power to Choose Your Path: Careers
0
0
663
Guidelines for Improving the Effectiveness of Boards of Directors of Nonprofit Organizations
Guidelines for Improving the Effectiveness of Boards of Directors of Nonprofit Organizations the Role of the Balanced Score Card, Aulgur found support for use of
0
2
86
Effect of low level radiation on the barrier qualities of spunbonded olefin
Two measures of transmission rate barrier effectiveness, porosity WVTR, are measured relationship between the barrier measures operate on different a finer test
0
0
78
Effect of polyethylene content on physical performance of carbon black filled elastomer/polyethylene blends
Variations of toughnessof EPDM/PE blends as a function of PE weight fraction EPDM has no effect on the tensile strength, while region II shows that incorporation of PE with greater
0
0
6
Development of Needle Punched Non Woven Fabric for Water Filteration
Based on above fabric properties like Fabric thickness, Air permeability and Pore size we selected 200 GSM Needle Punched Nonwoven Fabric made from Polyester and Polypropylene with
0
0
6
Effect of perforated foil and polypropylene fibre covers on development of early potato cultivars
The increase in soil temperature on average by 1.9°C in the morning hours and by 3.6°C at noon hours as a result of cover use in potato cultivation for the early crop forced the plants
0
0
6
Effect of perforated foil and polypropylene fibre covers on assimilation leaf area of early potato cultivars
MATERIAL AND METHODS The effect of cover type perforated polyethylene foil, polypropylene fibre and the date of its removal 2 and 3 weeks after plant emergence on the assimilation leaf
0
0
7
Determination of oxygen permeability and mechanical properties of the aluminium paper foils
Determination of moduli of elasticity in the longitudinal and transversal direction were provided and tensile properties as maximal elongations, maximal tensile forces, tensile
0
0
8
Show more