PRODUCT DATA SHEET Sika® Cable System

Corrosion protection for bridge cables of steel and galvanized steel

PRODUCT DESCRIPTION

The Sika Cable System consists of coating materials as well as a sealing respectively injection materials. Suitable for coating or sealing of bridge cables and steel constructions exposed to vibration as well as deformation.

Sika Cable FE Primer

Sika Cable FE Primer is a 2-pack low solvent containing primer coat based on epoxy resin. It contains active corrosion pigments, is versatile overcoat- able and adheres very well to steel.

Sika Cable ZN Primer

Sika Cable ZN Primer is a 2-pack low solvent containing primer coat based on epoxy resin. The product contains micaceous iron oxide, is versatile overcoatable, of high chemical and mechanical resistance and adheres very well to galvanized steel.

Sika Cable TOP-1

Sika Cable TOP-1 is a 2-pack low solvent content intermediate coat of low solvent content, based on polyurethane. It contains micaceous iron oxide and is of high elasticity, impact strength, wear resistance and very good corrosion protection. Sika Cable TOP-1 is high-build applicable and very fast curing.

Sika Cable TOP-2

Sika Cable TOP-2 is a 2-pack low solvent content, flexible, lightfast and weather resistant polyurethane top coating.

Low solvent content referring to Protective Coatings Directive of German Paint Industry Association (VdL-RL 04).

Sika Cable Flex-1

Sika Cable Flex-1 is a flexible, total solid 2-pack sealer based on polyurethane. Because of its high flexibility and expansion ability it is especially suitable for filling joints and gaps exposed to vibration (e.g. anchoring of bridge cables).

(2)

PRODUCT DESCRIPTION

(Continuation)

Sika Cable Flex-2

Sika Cable Flex-2 is a total solid, flexible injection resin of low viscosity based on polyurethane for filling hollow spaces, (e.g. in parallel cables) and has a high penetration ability.

Solvent free referring to Protective Coatings Directive of German Paint Industry Association (VdL-RL 04).

USES Flexible and high-build corrosion protection for bridge cables of steel and galvanized steel.

PROPERTIES - Very good corrosion protection characteristics - Flexible, even at low temperatures

- High weather and colour resistance

TESTS APPROVAL / STANDARDS

The system was tested and listed according to ‘ZTV-KOR Cables’

(German Guideline).

PRODUCT DATA

COLOUR SHADES Sika Cable FE Primer: Red brown, sand yellow Sika Cable ZN Primer: DB 703

Sika Cable TOP-1: DB 703, DB 601

Sika Cable TOP-2: RAL- and DB-colour shades upon request Sika Cable Flex-1: Grey

Sika Cable Flex-2: Beige

Because of the raw materials used, slight batch to colour variations are unavoidable.

PACKAGING Sika Cable FE Primer: 15 kg net.

Sika Cable ZN Primer: 15 kg net.

Sika Cable TOP-1: 3 kg net.

Sika Cable TOP-2: 3 kg net.

Sika Cable Flex-1: 2.5 litres Sika Cable Flex-2: 12.5 kg net.

Sika Thinner EG: 25, 10 and 3 litres

SHELF LIFE In originally sealed containers in a cool and dry environment:

Sika Cable FE and Sika Cable ZN Primer: 3 years

Sika Cable TOP-2: 2 years

Sika Cable TOP-1, Sika Cable Flex-1, Sika Cable Flex-2: 1 year

SYSTEMS

COATING SYSTEMS Steel:

1 - 2 x Sika Cable FE Primer, 50 microns NDFT per layer 2 - 3 x Sika Cable TOP-1, 150 microns NDFT per layer 1 x Sika Cable TOP-2, 60 microns NDFT

Galvanized steel:

1 x Sika Cable ZN Primer, 50 microns NDFT

2 - 3 x Sika Cable TOP-1, 150 microns NDFT per layer 1 x Sika Cable TOP-2, 60 microns NDFT

When overcoating Sika Cable TOP-2 the existing surface must be mechanically prepared.

Sika Cable Flex-1 and Sika Cable Flex-2 are applied directly on to the Sika Cable FE Primer respectivly Sika Cable ZN Primer.

(3)

SURFACE PREPARATION Steel:

Blast cleaned to Sa 2 ½ according to EN ISO 12944, part 4.

Free from dirt, oil and grease.

Galvanized steel:

Free from oil, grease and corrosion products.

Surface preparation according to ZTV-ING, part 4, section 5

‘Corrosion protection of cables and ropes’.

TECHNICAL DATA

MATERIAL CONSUMPTION

Product Specific

gravity liquid

Solids content approx. %

Theoretical material-consumption/VOC without loss for medium

dry film thickness

approx.

kg/L by vol.

by weight

dry microns

wet microns

approx.

kg/m²

VOC approx.

g/m² Sika Cable

FE Primer 1.6 62 80 50 80 0.130 25.8

Sika Cable

ZN Primer 1.6 60 77 50 85 0.130 30.7

Sika Cable TOP-1 1.5 85 92 150 175 0.265 21.2

Sika Cable TOP-2 1.4 64 78 60 95 0.130 28.9

Sika Cable Flex-1 and Sika Cable Flex-2: specific gravity: 1.2 kg/l consumption: approx. 1.2 kg per 1000 cm³ volume to be filled MIXING RATIO AND

APPLICATION TIME (20°C): Product Mixing proportion in parts by weight

Application time at 20°C

Sika Cable FE Primer 90 : 10 8 h

Sika Cable ZN Primer 90 : 10 8 h

Sika Cable TOP-1 85 : 15 1 ½ h

Sika Cable TOP-2 83 : 17 2 h

Sika Cable Flex-1 3,5 : 1 1 h

Sika Cable Flex-2 100 : 20 2 ½ h

RESISTANCE The Sika Cable System is resistant to weathering, water, de-icing salts, oils and grease.

HINTS OF APPLICATION

PREPARATION OF MATERIAL Coating materials:

Stir Component A very thoroughly using an electric stirrer. Add component B and mix both components very thoroughly (including sides and bottom of the container).

Sika Cable Flex-1 and Sika Cable Flex-2:

Stir component A slowly by means of an electric stirrer (max. 300 rpm), sub- sequently add hardener in the correct mixing proportion and mix intensively again using an electric stirrer (300 - 500 rpm) until a homogeneous mixture is achieved (min. 3 minutes). Take care that no air is entrapped.

(4)

APPLICATION METHOD Coating materials:

The method of application has a major effect on achieving uniform thickness and appearance. Adding solvents reduces the sag resistance and the dry film thickness. In case of application by roller or brush, additional applications may become necessary to achieve the required coating thickness, depending on type of construction, site conditions, colour shade etc. Prior to major coating operations a test application on site may be useful to ensure the selected application method will provide the requested results.

By brush and roller:

According to ZTV-KOR „Cables“ brushing is the preferred application method. Where light and intense colour shades are applied, a second top coat might become necessary.

Sika Cable Flex-1 and Sika Cable Flex-2:

The application technique depends on the design features of the project.

Steel has to be primed with Sika Cable FE Primer, galvanized steel with Sika Cable ZN Primer.

DO NOT THIN Sika Cable Flex-1 and Sika Cable Flex-2.

APPLICATION CONDITIONS Min. + 5 °C (material and surface)

Relative humidity: Max. 85 %, except the surface temperature is significantly higher than the dew point temperature, it shall be at least 3 K above dew point.

If necessary max. 5% Sika Thinner EG may be added to adapt the viscosity.

DRYING STAGE 6 (EN ISO 9117-5)

Product Dry film thickness + 10°C

after

+ 20°C after

+ 30°C after

Sika Cable FE Primer 50 μm 10 h 3 ½ h 2 h

Sika Cable ZN Primer 50 μm 12 h 6 h 6 h

Sika Cable TOP-1 150 μm 20 h 20 h 15 h

Sika Cable TOP-2 60 μm 15 h 6 h 4 h

SHORE-HARDNESS

Product Shore hardness A

Sika Cable Flex-1 35 - 45

Sika Cable Flex-2 60 - 80

WAITING TIME BETWEEN COATS Minimum 24 h at + 20°C

FINAL DRYING TIME Depending on layer thickness and temperature final hardness is achieved within 1 - 2 weeks.

THINNER Sika Thinner EG

(5)

IMPORTANT NOTICE

EU-DIRECTIVE 2004/42/EC (DECOPAINT)

For product category IIA / j, Type Sb, the maximum permissible content of VOC according to the EU-Directive 2004/42/EC is 500 g/litre (limit 2010).

The maximum VOC-value of Sika Cable System is below 500 g/litre.

VALUE BASE All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control.

LOCAL RESTRICTIONS Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields.

HEALTH AND SAFETY INFORMATION

Skin contact with epoxy resins can lead to allergies!

Avoid direct skin contact at all costs when handling epoxy resins!

For the selection of suitable protective equipment, we have made our information data sheets 7510 ‘General notes on occupational safety’ and 7511 ‘General notes for wearing protective gloves’ available at www.sika.de.

In conjunction with this we also recommend the BG Bau service pages for information regarding the handling of epoxy resins

(www.gisbau.de/service/epoxi/epoxi.htm).

Information on the safe handling of chemical products, as well as the essen- tial physical, safety-related, toxicological and ecological data can be found in the current safety data sheets. Observe all relevant regulations, e.g. the hazardous substances act. Further notes and information data sheets on product safety and disposal can be found on the Internet at www.sika.de.

LEGAL NOTES The information, and, in particular, the recommendations relating to the application and end- use of Sika products, are given in good faith based on Sika’s current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accord- ance with Sika’s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product’s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products.

The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. The most recent product data sheet applies. This can be requested from us or is available to download at www.sika.de. Please check availability of local product data sheet at your local website. In cases of doubt the German text is valid.

Sika Deutschland GmbH Industrial Coatings Rieter Tal

71665 Vaihingen / Enz Germany

www.sika.de

Version given by Industrial Coatings Phone: (07042) 109-0 Fax: (07042) 109-180

Mail: industrial-coatings@de.sika.com

© 2014 Sika Deutschland GmbH

References

Related documents

Microsystem Devices for Healthcare Applications 2011 & 2018 market in M$ EXECUTIVE SUMMARY 0 1000 2000 3000 4000 5000 6000 7000 2011 2012 2013 2014 2015 2016 2017 2018.. BioMEMS

With all the research choice variables being contractible, the Government decides: whether it asks the University to undertake the specialized research or interdis- ciplinarity, what

A splatter coat of Sika ® -1 render mortar or Sika Spritz and Bonding mortar, mixed with plain clean water or gauging liquid, is then applied to serve as a key for

Sensitization, Skin Category 1 – May cause an allergic skin reaction Hazardous to the aquatic environment, acute hazard Category 1 – Very toxic to aquatic life.. Hazardous to

Skram, “Interview: Arild-Inge Skram, Former Chief of the Norwegian Coast Guard”; Norwegian Coast Guard Official II, “Interview: Norwegian Coast Guard Leadership”;

Sika Limited and Sika Ireland Limited are part of the global Sika Group, specialising in the manufacture and supply of chemical based products. Sika has a leading position in

The Ministry of Community Development, Youth and Sports (MCYS) is the lead agency in Singapore for supporting families at risk or in distress. MCYS plays a key role in charting

Sika® Unitherm® Platinum is a solvent-free, 100 % solids, 2-pack, modified epoxy based intumescent fire protection coating for internally or externally exposed structural