STANDARD SPECIFICATIONS FOR DESIGN AND CONSTRUCTION OF WATER LINES AND SEWER LINES
221
0
0
Full text
Outline
SITE PREPARATION
EXCAVATION, BACKFILLING, AND COMPACTING
COLD WEATHER INSTALLATION
REJECTION OF PRECAST MANHOLE SECTIONS
PRODUCTS 2.01 MATERIALS
PUMPING EQUIPMENT
CONCRETE THRUST BLOCKS AND ANCHOR COLLARS
INSPECTION AND TESTING OF WATER LINES AND SERVICE LINES
PAVEMENT REPAIR
LAWN AND GRASS RESTORATION
Related documents
Manholes are to be located at the end of each line and at all changes in pipe size, material, grade, and alignment and are to be installed in accordance with Standard Details
The purchasers of new homes, as well as the owners of existing residential property that may require the installation of residential sprinklers as a condition of future development
Determine the location of point repairs by smoke testing or video inspection of the sewer line between the manhole sections where the failed pipe is located.. The
The Contractor shall furnish all labor, supervision, tools, equipment, appliances, and materials to perform all operations in connection with bypass pumping of