• No results found

PILine XY Stage System with Controller and Joystick

N/A
N/A
Protected

Academic year: 2021

Share "PILine XY Stage System with Controller and Joystick"

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

Stable, Dynamic, Low Profile

Reference-class microscope XY stage

System consisting of XY stage, controller, USB joystick, and appropriate cables. Large clear aperture 160 mm × 110 mm.

Accessories necessary: Sample holder, fine positioning stages, and Z stages

You will find matching fine positioning stages (X / Y / Z / ΘX / ΘY / ΘZ), sample holders (microscope slide, holder for Petri dishes, and microtiter plates), as well as any adapter plates necessary in our "Microscope Stage Configurator" brochure.

Suitable for the following inverted microscopes:

Nikon Eclipse Ti / Ti2

Olympus IX / IX2 / IX3

Leica DMI6000 / DMI8

High-resolution PILine® piezo linear drive

Self-locking at rest. Low noise. Highest stability due to low thermal load and no lubricants. Large dynamics range of 10 µm/s to 120 mm/s, ideal for operating with joystick and automated high-content processes.

Highly accurate position measuring with incremental linear encoder

Noncontact optical encoders measure the actual position directly at the motion platforms with the greatest accuracy so that nonlinearity, mechanical play or elastic deformation have no influence on position measuring.

User software

PIMikroMove. PI General Command Set (GCS). Drivers for NI LabVIEW. Compatible with µManager, MetaMorph, Andor iQ, MATLAB.

U-780

PILine® XY Stage System with Controller and Joystick

High velocity constancy at 10 µm/s

Velocity to 120 mm/s, resolution 0.1 µm

Travel ranges to 135 mm × 85 mm

(depending on model type)

For inverted microscopes, freely revolving

nosepiece

Compact, low-profile design: Unrestricted

access to the sample

(2)

Application fields

For inverted microscopes from Nikon, Olympus and Leica, versions for other microscopes available on request. For super-resolution microscopy, tiling, automated scanning microscopy.

Specifications

Motion and positioning U-780.DNS U-780.DOS U-780.DLS Unit Tolerance

System with M-687.UN for Nikon microscopes

System with M-687.UO for Olympus microscopes

System with M-687.UL for Leica microscopes

Active axes X, Y X, Y X, Y

Travel range 135 mm × 85 mm 100 mm × 75 mm 135 mm × 85 mm

Integrated sensor Linear encoder Linear encoder Linear encoder

Sensor resolution 0.1 0.1 0.1 µm

Bidirectional repeatability ±0.3 ±0.3 ±0.3 µm

Pitch / yaw ±300 ±300 ±300 µrad typ.

Velocity 120 120 120 mm/s max.

Reference switch Optical, 1 µm

repeatability

Optical, 1 µm repeatability

Optical, 1 µm repeatability

Limit switches Hall effect Hall effect Hall effect

Mechanical properties U-780.DNS U-780.DOS U-780.DLS Unit Tolerance

Load capacity 25 25 25 N max.

Drive properties U-780.DNS / U-780.DOS / U-780.DLS

Motor type PILine® ultrasonic piezo motor, performance class 2

Miscellaneous U-780.DNS U-780.DOS U-780.DLS Unit Tolerance

Operating temperature range 20 to 40 20 to 40 20 to 40 °C

Material Al (black anodized) Al (black anodized) Al (black anodized)

(3)

Piezo motor controller U-780.DNS / U-780.DOS / U-780.DLS

Type C-867.2U2 with USB joystick

Interface / communication USB, RS-232, SPI, Ethernet

I/O lines

4 analog / digital inputs

4 digital outputs to mini DIN, 9-pin Digital: TTL

Analog: 0 to 5 V

Command set PI General Command Set (GCS)

User software PIMikroMove

Software drivers GCS DLL (with code examples for the most common programming languages such as C++, C#, VB.NET, Python,

Delphi), driver for NI LabVIEW, MATLAB library

Supported functions Startup macro, macro, data recorder for recording operating data such as motor voltage, velocity, position or

position error

(4)

Drawings / Images

M-687.UL for Leica microscopes, dimensions in mm

(5)

M-687.UO for Olympus microscopes, dimensions in mm

Ordering Information

U-780.DNS

PILine® XY stage system, travel range 135 mm × 85 mm, for inverted microscopes from Nikon, with controller and joystick

U-780.DOS

PILine® XY stage system, travel range 100 mm × 75 mm, for inverted microscopes from Olympus, with controller and joystick

U-780.DLS

PILine® XY stage system, travel range 135 mm × 85 mm, for inverted microscopes from Leica, with controller and joystick

Accessories

M-687.AP1

Universal holder for microscope slide and Petri dishes for PI stages with 160 mm × 110 mm clear aperture

P-736.WPO

Holder for microtiter plates, for P-736.ZxO PInano® Z piezo scanner for inverted Olympus microscopes with large aperture for microtiter plates

P-736.WPN

Holder for microtiter plates, for P-736.ZxN2 PInano® Z piezo scanner for inverted Nikon microscopes with large aperture for microtiter plates

P-736.UHN

Universal holder for microscope slides and Petri dishes, for P-736.ZxN2 PInano® Z piezo scanner for inverted Nikon microscopes with large aperture for microtiter plates

P-736.PDO

(6)

P-736.PDN

References

Related documents

The second sudden southward turning of IMF Bz that caused intensi fication of the storm (in the recovery phase) resulted in prompt penetration of eastward IEF to low-latitude

The main change in terms of teaching method is that in 2012, the traditional 2 hours of in-person lecture per week was used, whereas the 2014 offering the online video recording

Initially studies solely from the UK were sought, though research relating to paramedics using alternative intubation devices (AIDs) in the UK is extremely limited,

First Name Last Name Company Email Job Title Work Phone Cell Phone Fax Number. Veronica Meiller Solitas House

Knowledge of cultural worldview frameworks Demonstrates sophisticated understanding of the complexity of elements important to members of another culture in relation to

3 From the New Equipment Requests composite form, you can add a new asset, calculate an asset, review calculated details, view the impact of the request on your financial

The data provided in the multifactorial sub-challenge of DREAM4, consisted of in silico networks of gene expression measurements of steady-state levels, obtained by applying

For example, civil judicial reviews for immigration and asylum rose from 51% of all cases in 2000 to 84% of all cases in 2013, 47% in 2014 and 57% in 2015 - these types of