CP

(2)

CP (compartment panels)

Door with all round

formed in place Polyurethene (PU) gasket

PU gasket ensures a reliable seal 1

Door opening 130°

Heavy duty casting hinges / cam lock

Door opening left to rignt,

(can be changed to opposite direction) 2

Hemming of the door frame edges of the body

For proper sealing with

PU gasket & increased gasket life Protection against scratches & cuts 3

Mounting plate in 2.5-mm Galvanized sheet

& it can be adjustable 25-mm front & back

Maximum Distance from door to mounting plate - 325-mm 6

Offset for top & bottom cutout

Ensures fulfilment of protection class

3-mm gland plate with 3-mm thk gasket sealing 4

Accessories

7a– Cable support bracket on Ø22.5 hole 7b – Pad lock arrangement

7

Protection Category - IP54

1.5-mm inspection cover with 3-mm thk gasket sealing

5

Material

- Body : Sheet steel

- Door : Sheet steel, All round Formed in place PU seal

Surface finish

- Body, partitions, covers, Gland plate & Door : Dipcoat

primed + powder coated textured paint - Mounting plate : G I Sheet

Colour

- RAL7035 & 7035 textured paint Other colours available on request

Supply includes

- Body, partitions, covers,

- Door - 130° opening heavy duty hinges / cam lock Door opening left to rignt (left side lock / right side hinge) (can be changed to opposite direction)

- Mounting plate - Gland plate

- Horizontal & vertical partitions - Lifting angle 7b 7a 1 2 3 4 5 6

(3)

02

CP (ACB) panel for

single front

&

double front

`

Back-side Inspection Cover 1.5-T Top Front Inspection Cover 1.5-T Back-side Gland plate 3-T can be changed with top inspection cover for cable entry from top ACB compartment

Includes

-- Door

- Depthwise channel (4 Nos.) - ACB mtg channel (2 Nos.) - Back side widthwise channel for vertical busbar Support (2 Nos.)

- Horizontal partition upto 400D

- Both side vertical partition up to 400D Metering compartment Includes -- Door - Mounting plate - Horizontal partition up to 400D - Both side vertical partition up to 400D

SF-HBC Included

-- Front screwed cover - Horizontal partition up to 400D

Lifting angle

(Length as per shipping section) HBC height (300, 350, 400) Trim comp. height (50, 100, 150 & 200) Metering comp. height (400 & 500) ACB comp. height (As required) Empty comp. height (As required)

W

D

H

Empty compartment Includes -- Door - Mounting plate - Cross channel

for mounting plate (2 Nos.) - Both side vertical partition up to 400D

Trim cover

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

W 600 800 D 800 1000 H 2000 2200 Full height Back cover 1.5-T TOP HBC BOT HBC

Horizontal busbar chamber possible on Top & Bottom As per above pictures

Full height Back cover 1.5-T Full height Back cover 1.5-T

Top Gland plate 3-T

Bottom Gland plate 3-T Inspection cover at bottom

Inspection cover at top

ACB

panel

HORIZONTAL BUS BAR SUPPOUT KIT

(optional as per requirment) INCLUDES

-- Depthwise channel – 2--nrs - Fitting hardware

(4)

CP (SF-FDR) panel for

Single front

TOP HBC

BOT HBC

Horizontal busbar chambers possible on Top & Bottom As per above pictures

Inspection cover at top Inspection cover at top

No gland plate No gland plate ANY SIZE COMBINATION AVAILABLE FROM ABOVE

W 500 600 700 800 D 400 500 600 800 1000 H 2000 2200 HBC height (300, 350, 400) Trim comp. height (50, 100, 150 & 200)

Feeder comp. sets height (As required)

W

D

H

Top Inspection Cover 1.5-T Feeder compartment's (sizes as required) Included -- Door, - Mounting plate - HorIzontal partition up to 400D - depth-wise vertical partition on both sides

SF- HBC Includes -- Front screwed cover - Horizontal partition up to 400D Lifting Angle

(Length as per shipping section) Trim cover Full Height Back cover 1.5-T No gland plate

FEEDER

panel

HORIZONTAL BUS BAR SUPPOURT KIT

(optional as per requirment) INCLUDES-- Depthwise channel – 2INCLUDES--nrs - Fitting hardware Feeder height 250 300 350 400 500 600 700 800 900 1000

(5)

CP (DF-FDR) panel for

Double front

HBC height (300, 350, 400) Front & back

Trim comp. height (50, 100, 150 & 200)

Front & back Feeder comp. sets height

(As required)

Front & back

D

H

W

Lifting Angle

(Length as per shipping section) Top Inspection Cover 1.5-T Feeder compartments (sizes as required) Includes -- Door - Mounting plate - Horizontal partition up to 400D - Depth-wise vertical partitions on both sides

DF- HBC Includes

-- Front & Back screwed cover - Horizontal partition Trim cover Feeder compartments (sizes as required) Includes -- Door - Mounting plate - Horizontal partition up to 400D - Depth-wise vertical partitions on both sides

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

W 500 600 700 800

D 800 1000

H 2000 2200

TOP HBC

Inspection cover at top Inspection cover at top

Horizontal busbar chamber possible on Top & Bottom As per above pictures

No gland plate No gland plate

No gland plate

FEEDER

Panel

BOT HBC 04 Feeder height 250 300 350 400 500 600 700 800 900 1000

(6)

Feeder height 250 300 350 400 500 600 700 800 900 1000

Feeder compartment

Includes -- Door - Mounting plate - Horizontal partition up to 400D - Depth-wise vertical partition on both sides

FEEDER

Panel

Feeder details

Mounting plate

(7)

06

CP (SF-VCA) panel for

Single front

TOP HBC

Top Gland plate 3-T

Inspection cover at top

BOT HBC

Bottom Gland plate 3-T Inspection cover at bottom

Horizontal busbar chamber possible on Top & Bottom As per above pictures

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

W 300 400 D 400 500 600 800 1000 H 2000 2200 HBC height (300, 350, 400) Trim comp. height (50, 100, 150 & 200)

Vertal cable comp. height (As required) Inspection Cover 1.5-T SF- HBC Included

-- Front screwed cover - Hor partition full depth

Lifting Angle

(Length as per shipping section) VCA compartment Included -- Door (1 Nos) Trim cover Full height Back cover 1.5-T Full height Back cover 1.5-T Full height Back cover 1.5-T Gland plate 3-T can be changed with top inspection cover for cable entry from top

W

D

H

Vertical Cable

Alley

VERTICAL CABLE SUPPORT KIT (optional as per requirment) INCLUDES

-- Cross channel – (8 Nos.)

- Terminal mounting bracket– (8 Nos.) - Fitting hardware

Cable tray not included with cable support kit Available on request

(8)

CP (DF-VCA) panel for

Double front

HBC height (300, 350, 400) Trim compartment height (50, 100, 150 & 200)

Vertical cable compartment Height

(As required)

W

H

D

TERMINAL & CABLE MOUNTING TRAY SET (Refer Accessories Page)

TOP HBC

Top Gland plate 3-T

Inspection cover at top

BOT HBC

Bottom Gland plate 3-T Inspection cover at bottom

Horizontal busbar chamber possible on Top & Bottom As per above pictures

ANY SIZE COMBINATION AVAILABLEFROM ABOVE TABLE

W 300 400

D - - - 800 1000

H 2000 2200

Lifting Angle

(Length as per shipping section)

Inspection Cover 1.5-T

DF- HBC

Includes-- Front screwed cover - Horizontal partition full depth

VCA compartment Includea -- Door (1 Nos) Trim cover VCA compartment Includes -- Door (1 Nos)

Vertical Cable

Alley

VERTICAL CABLE SUPPORT KIT (optional as per requirment) INCLUDES

-- Cross channel – (8 Nos)

- Terminal mounting bracket – (8 Nos) - Fitting hardware

Cable Tray not included with cable support kit Available on request

(9)

08

CP (VBC) panel for

Single front

&

Double front

VERTICAL BUS BAR SUPPORT KIT (optional as per requirment) INCLUDES

-- Horizontal channel – (8 Nos) - Depthwide channel – (8 Nos) - Fitting hardware

Horizontal busbar chamber possible on Top & Bottom As per above pictures

TOP HBC BOT HBC Horizontal partition Horizontal partition

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

W 300 400 D 400 500 600 800 1000 H 2000 2200 HBC height (300, 350, 400) Trim compartment Height (50, 100, 150 & 200)

Vertical Busbar compartment. Height (As required)

W

D

H

Inspection Cover 1.5-T SF- HBC Includes

-- Front screwed cover (without horizontal partition)

Lifting Angle

(Length as per shipping section)

VBC compartment Includes

-- Front screwed cover (1 Nos)

Trim cover Full height Back cover 1.5-T Full height Back cover 1.5-T Full height Back cover 1.5-T

Full Depth Horizontal partition

1.5-T

Vertical Busbar

Chamber

(10)

CP (PLC) Panel for S

ingle front

& D

ouble front

Gland plate 3-T

can be changed with top inspection cover for cable entry from top Inspection

Cover 1.5-T

Lifting Angle

(Length as per shipping section) FULL HEIGHT DOOR 2-mm Single door For 500, 600, & 800W Double door for 1000 & 1200W

Back-side full height Door or

Screwed Cover

Type-A

Internal Arrangement Depth-wise channel (8 Nos) Width-wise channel (4 Nos)

Type-B

Internal Arrangement Full Height Mounting Plate (Front & Back options)

Type-C

Internal Arrangement Partial Height Mounting Plate (Front & Back options)

W 500 600 800 1000 1200

D 400 500 600 800 1000

H 2000 2200

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

PLC

Panel

(11)

10

CP (DRV) Panel for S

ingle front

& D

ouble front

Gland plate 3-T

can be changed with top inspection cover for cable entry from top Inspection

Cover 1.5-T

Lifting Angle

(Length as per shipping section) FULL HEIGHT DOOR 2-mm Single door For 500, 600, & 800W Double Door for 1000 & 1200W

Back-side full height Door or

Screwed Cover

Type-D

Internal Arrangement

Partial Height Mounting Plate (1 Nos) Width-wise channel for Drive resting (2 Nos) Front & Back Protection cover (2 Nos) Horizontal partition (1 Nos)

Mesh Canopy

for ventilation Fan Canopy with centrifugal fan 860m3/hr Fan Canopy without fan W - 600 800 1000 1200 D - 500 600 800 1000 H 2000 2200

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

DRIVE

Panel

(12)

CP (MRS) Panel for S

ingle front

& D

ouble front

Gland plate 3-T

can be changed with top inspection cover for cable entry from top Inspection

Cover 1.5-T

Lifting Angle

(Length as per shipping section) FULL HEIGHT DOOR 2-mm Single door For 400, 500, 600, & 800W

Back-side full height Door or

Screwed Cover

Type-A

Internal Arrangement Depth-wise channel (8 Nos) Widthwise channel (4 Nos)

Type-B

Internal Arrangement Full Height Mounting plate (front & back options)

Type-C

Internal Arrangement Partial Height Mounting plate (front & back options)

Mesh Canopy

for ventilation Fan Canopy with Centrifugal fan 860m3/hr Fan Canopy without fan W 400 500 600 800 D 400 500 600 800 1000 H 2000 2200

ANY SIZE COMBINATION AVAILABLE FROM ABOVE

Marshaling

Panel

(13)

L-20 Additional MIDC

SATARA – 415004, INDIA.

Tel: +91 2162 240431,

+91 2162 240284 / 87

Fax: +91 2162 240432

E-mail: [email protected]

Website: www.bartakke.co.in

References

Related documents

Resume recovery feature of Stellar Phoenix Photo Recovery allows you to recover photos, audio and video files using saved scan information file or image file.. You can use the

A process was developed to identify potential defects in previous layers of Selective Laser Melting (SLM) Powder Bed Fusion (PBF) 3D printed metal parts using a mid-IR thermal camera

The companies Berlin Partner GmbH and ZukunftsAgentur Branden- burg GmbH (Brandenburg Economic Development Board) support with a large range of services, from recruiting

Facet joint arthropathy - osteophyte formation and distortion of joint alignment MRI Axial T2 L3-L4 disk Psoas Paraspinal muscles Psoas Paraspinal NP AF MRI Axial T2 PACS, BIDMC

Motivation Problem statement Simulation scenario Results of performance prediction ConclusionsB. A study on machine learning and regression based models for performance

In the previous sections, we dis- cuss the expectation that a neural network exploiting the fractional convolution should perform slightly worse than a pure binary (1-bit weights

Steele of Stanford University Online High said that shift is already underway: In a recent survey of ASCA members, she and her colleagues found that more than one-fourth of

College Mathematics (3 Credits) Biology (6 Credits) Arts and Humanities 3 Arts and Humanities 3 TOTAL 35 20 8.00 **Total up RED # ** Excess credits 0.00 8.00 Analyzing and