HIMAP- BC

HYUNDAI HEAVY INDUSTRIES CO. LTD

BAY CONTROLLER

Appendix 4

Connection drawings

(2)

Version:

06.02.2007 (RR)

File: HIMAP_A4_Connectiondrawings_E.doc

-

CU:

1.10 / 10.10.2003

-

MU:

1.10 / 17.04.2003

-

RU:

1.10 / 18.09.2003

(3)

HYUNDAI HIMAP

HIMAP_A4_Connectiondrawings_E.doc

3/11

Table of content

HIMAP -BC/-BCG: Generator for ship application with differential protection ... 4

HIMAP -X/-XG: Generator for ship application ... 4

HIMAP-BC/-BCG Generator/Motor 3xCT’s (protection, meassurement and differential) .. 4

HIMAP -BC/-BCG... 4

HIMAP -BC/-BCG... 4

HIMAP -BC/-BCG... 4

HIMAP-BC/-BCG... 4

(4)

HIMAP -BC/-BCG: Generator for ship application with differential protection

Power supply 24 V DC 1 2 CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

+ 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 X1 = Type 3 21 20

X 2.3

Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V H H L Tx B (-) Tx A (+) Rx B (-) Rx A (+)

X 1

19 18 4 mm² I G1 13 14 6 5 4 3 2 1 I 1 I 2 I 3

CT

P1 P2 P1 P2 P1 P2 11 10 9 8 7 I D1 I D2 I D3 12

CT

P1 P2 P1 P2 P1 P2

G

3~

X 1

Drawing 1 G1 using of ZCT see: 1 F2

for low

voltage

400 - 480 V

L3

L2

L1

18 20 22 U B11 U B12 U B13

X 1

17 19 21

X 1

U U 2 U 3

CB

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA 49 50 51 52 53 + + + + - - - - + 24 V

SERIES

-BC/-BCG

ANSI LIST (see Users Manual) Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in Fct. 13 in Shunt 1 (TRIP) Shunt 2 Synchr. on Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out 26 4 mm²

X 1

3 Frame Ground L DE-Exitation

(5)

HYUNDAI HIMAP

HIMAP_A4_Connectiondrawings_E.doc

5/11

HIMAP -X/-XG: Generator for ship application

9 11 13 Power supply 24 V DC 1 2 10 12 14

X 1

CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

18 Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in + 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 Shunt 1 (TRIP) Shunt 2 Synchr. on Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out Fct. 2 out DE-Exitation 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 U 1 U 2 U 3 X1 = Type 11 U B11 U B12 U B13 21 20

X 2.3

Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V Drawing 1 G2 H L H L Tx B (-) Tx A (+) Rx B (-) Rx A (+) Frame Ground 19 18 4mm² 4mm²

X 1

G

3~

for low

voltage

400 - 480V

Fct. 13 in

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA 49 50 51 52 53 + + + + - - - - + 24 V

X 1

4mm²

CB

L3

L2

L1

SERIES

-X/-XG

ANSI LIST (see Users Manual)

X 1

I G1 7 8 6 5 4 3 2 1 I 1 I 2 I 3

CT

P1 P2 P1 P2 P1 P2 using of ZCT see: 1 F2 3

(6)

HIMAP-BC/-BCG Generator/Motor 3xCT’s (protection, meassurement and differential)

17 19 21 Power supply 1 2

X 1

CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

+ 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 U 1 U 2 U 3 X1 = Type 2 U B11 U B12 U B13 21 20

X 2.3

Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V H L H L Tx B (-) Tx A (+) Rx B (-) Rx A (+) 19 18 4 mm² Meassurement - CT 11 10 9 8 7 I D1 I D2 I D3 12 Protection - CT P1 P2 P1 P2 P1 P2

G

3~

M

3~

X 1

Drawing 1 MG1 Synchr. on 18 20 22

X 1

L3

L2

L1

CB

G

3~

G

3~

Protection - CT

PT

PT

Shunt 1 (TRIP) Shunt 2 Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out Fct. 2 out Failure Lock out Relay 4 mm² 26 Frame Ground

X 1

I G2 15 16 25 24 23 I 1 I 2 I 3 P1 P2 P1 P2 P1 P2

X 1

I G2 13 14 6 5 4 3 2 1 I 1 I 2 I 3 P1 P2 P1 P2 P1 P2 Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 13 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA 49 50 51 52 53 + + + + - - - - + 24 V using of ZCT see: 1 F2

SERIES

-BC/BCG

ANSI LIST (see Users Manual) 3

(7)

HYUNDAI HIMAP

HIMAP_A4_Connectiondrawings_E.doc

7/11

HIMAP -BC/-BCG

CB

17 19 21 Power supply 1 2 18 20 22

X 1

26 CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 13 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in + 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 Shunt 1 Shunt 2 Synchr. on Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out Fct. 2 out Failure Lock out Relay 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 U 1 U 2 U 3 X1 = Type 1/3 U B11 U B12 U B13 21 20

X 2.3

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

49 50 51 52 53 54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V + + + + - - - - H L H L Tx B (-) Tx A (+) Rx B (-) Rx A (+)

L1 L2 L3

PT

Frame Ground 15 16 U G1

X 1

19 18 4 mm² 23 24 25 23 24 25 U B21 U B22 U B23 I G1 13 14 6 5 4 3 2 1 I 1 I 2 I 3

CT

P1 P2 P1 P2 P1 P2

BUS 2

L3

L2

L1

4 mm²

X 1

L3

L2

L1

PT

BUS 1

PT

11 10 9 8 7 I D1 I D2 I D3 12

CT

P1 P2 P1 P2 P1 P2

G

3~

M

3~

CB

G

3~

G

3~

X 1

Drawing using of ZCT see: 1 F2 + 24 V

SERIES

-BC/-BCG

ANSI LIST (see Users Manual) 3

(8)

HIMAP -BC/-BCG

2F3 2F1

CB

17 19 21 Power supply 1 2 18 20 22

X 1

26 CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 13 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in + 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 Shunt 1 Shunt 2 Synchr. on Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out Fct. 2 out Failure Lock out Relay 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 U 1 U 2 U 3 X1 = Type 1 U B11 U B12 U B13 21 20

X 2.3

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

49 50 51 52 53 54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V + + + + - - - - H L H L Tx B (-) Tx A (+) Rx B (-) Rx A (+)

L1 L2 L3

PT

Frame Ground 15

X 1

19 18 4 mm² 23 24 25 23 24 25 U B21 U B22 U B23 I G1 13 14 6 5 4 3 2 1 I 1 I 2 I 3

CT

P1 P2 P1 P2 P1 P2

BUS 2

L3

L2

L1

4 mm²

X 1

L3

L2

L1

PT

BUS 1

PT

CB

Drawing using of ZCT see: 1 F2 + 24 V

OUTGOING

M

3~

INCOMING

G

3~

SERIES

-BC/-BCG

3 ANSI LIST Users Manual

(9)

HYUNDAI HIMAP

HIMAP_A4_Connectiondrawings_E.doc

9/11

HIMAP -BC/-BCG

CB

17 19 21 Power supply 1 2

X 1

26 CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 13 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in + 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 Shunt 1 Shunt 2 Synchr. on Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out Fct. 2 out Failure Lock out Relay 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 U 1 U 2 U 3 X1 = Type 5 21 20

X 2.3

Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V H L H L Tx B (-) Tx A (+) Rx B (-) Rx A (+)

L1 L2 L3

PT

Ground Frame

X 1

19 18 4 mm² I G1 13 14 6 5 4 3 2 1 I 1 I 2 I 3

CT

P1 P2 P1 P2 P1 P2 11 10 9 8 7 I D1 I D2 I D3 12

CT

P1 P2 P1 P2 P1 P2

X 1

Drawing 2 T1 using of ZCT see: 1 F2

N L1 L2 L3

I G2 16 15 P2 P1 18 20 22 23 24 23 24 25 25 U B11 U B12 U B13 U B21 U B22 U B23

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA 49 50 51 52 53 + + + + - - - - + 24 V

SERIES

-BC/-BCG

ANSI LIST (see Users Manual)

BUS 2

L3

L2

L1

4 mm²

X 1

L3

L2

L1

PT

BUS 1

PT

3

(10)

HIMAP-BC/-BCG

17 19 21 Power supply 1 2 CAN2 CAN1 RS485/422 22 23 24 25 26 27 28 29 serial communication

X 2.2

Fct. 23 in Fct. 10 in Fct. 11 in Fct. 12 in Fct. 13 in Fct. 14 in Fct. 15 in Fct. 16 in Fct. 17 in Fct. 18 in Fct. 19 in Fct. 20 in Fct. 21 in Fct. 22 in + 24 V 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 Shunt 1 Shunt 2 Synchr. on Fct. 8 out Fct. 7 out Fct. 6 out Fct. 4 out Fct. 3 out Fct. 5 out Common Common Common Fct. 1 out Fct. 2 out Failure Lock out Relay 46 47 48 + 24 V

X 2.1

X 2.3

Pick up Input 3 U 1 U 2 U 3 X1 = Type 5 21 20

X 2.3

Current in 4 4..20 mA Current in 3 4..20 mA Current in 2 4..20 mA Current in 1 4..20 mA + 24 V

X 3

54 55 56 57 58 L1 (+) N (-)

X 2.4

+ 24 V H L H L Tx B (-) Tx A (+) Rx B (-) Rx A (+)

L1 L2 L3

6 5 4 3 2 1 I 1 I 2 I 3

PT

CB

X 1

CT

P1 P2 19 18 P1 P2 P1 P2

FEEDER

OUTGOING1

CT

P1 P2 P1 P2 P1 P2

FEEDER

OUTGOING2

CT

P2 P1 P2 P1 P2 8 10 9 11 12 I D1.2 I D1.3 7 I D1.1 14 16 15 I D2.2 I D2.3 13 I D2.1

X 1

26 4 mm² P1 Drawing 2T2 18 20 22 23 23 24 25 U B11 U B12 U B13 U B21 U B22 U B23 Frame Ground

X 2.4

Current out 4 4..20 mA Current out 3 4..20 mA Current out 2 4..20 mA Current out 1 4..20 mA 49 50 51 52 53 + + + + - - - - + 24 V

BUS 2

L3

L2

4 mm²

X 1

L3

L2

L1

PT

PT

SERIES

-BC/-BCG

ANSI LIST (see Users Manual)

BUS 1

Frame Ground 3

(11)

HYUNDAI HIMAP

HIMAP_A4_Connectiondrawings_E.doc

11/11

HIMAP -BC/-BCG PT/CT examples

6 5 4 3 2 1 I 1 I 2 I 3

X 1

CT

P1 P2 P1 P2 P1 P2 I G1 13 14

USING GROUND

CT

X 1

6 5 4 3 2 1 I 1 I 2 I 3

CT

P1 P2 P1 P2 P1 P2 I G1 13 14

ZCT

P1 P2 17 (9) 19 (11) 21 (13)

X 1

17 (9) 19 (11) 21 (13)

X 1

PT

References

Related documents

Professor Spector stated that as per Article III of the Bylaws, the College Assembly is responsible for making recommendations affecting academic, student and other college affairs

Work-Family Conflict (X1) memiliki pengaruh yang tidak signifikan dan arah hubungan negatif terhadap job performance (Y) , karena nilai T statistik sebesar 0,248 yang

Obtain mean and turbulence quantities through a M=2.5 SWBLI of sufficient quantity and quality to be considered as a CFD validation dataset.. Initial efforts will focus on a Mach

;. :ARRA"&I@S) &he #essee has made the selection of the @'uipment %ased upon its own  judgement prior to the purchase thereof %y the #essor and expressly declares that

some newsworthiness judgments fall to policymakers who are lower on the Facebook totem pole, but the important point is that these decisions are made by humans—not

On all three of the dimensions used to assess IP management – governments’ abilities to determine which knowledge becomes private property, to provide for exceptions to

Desktop Support Services recommends a plan to replace the current help desk software. By replacing Service Center with software that is developed by current resources in ITS the

In a lipotoxic model of NASH: mice fed a high-cholesterol and high-fat diet, astaxanthin alleviated excessive hepatic lipid accumulation and peroxidation, increased the proportion