(1)

22 63 3 - D es ig ne d an d pr od uc ed b y Pa rt ne rs in C om m un ic at io n 02 0 87 63 1 32 3 04 / 11

Prices and specifications subject to change without prior notice.

Split and Multi-Split Systems

KX6 VRF Inverter Systems

PRICE LIST

May 2011

Bedford Tel: 01234 272702 Birmingham Tel: 0121 313 6720 Bristol Tel: 01454 456430 Bury St. Edmunds Tel: 01359 270888 Fareham Tel: 01329 443515 Glasgow Tel: 0141 420 1606 Leeds Tel: 0113 277 5000 London - Merton Tel: 0208 544 1010 London - Stratford Tel: 0208 558 4021 Newcastle Tel: 0191 258 3492 Norwich Tel: 01603 409616 Sheffield Tel: 0114 244 8222 Slough Tel: 01753 495710 Southampton Tel: 02380 869966 Swanley Tel: 01322 614811 Walthamstow Tel: 0208 531 9321 Warrington Tel: 01925 837688 Head Office

Rougham Industrial Estate Rougham,

Bury St Edmunds Suffolk IP30 9XA Tel: 01359 270888 Fax: 01359 271132 headoffice@hrpltd.co.uk www.hrponline.co.uk

HRP OEM & Export Rougham Industrial Estate Rougham

Bury St. Edmunds Suffolk IP30 9XA Tel: 01359 272 221 Fax: 01359 272 222 oem.sales@hrponline.co.uk www.hrponline.co.uk 3D Air Sales Ltd 159 Edinburgh Avenue Slough Trading Estate Slough SL1 4UE Tel: 01753 495720 Fax: 01753 495721 sales@3dair.co.uk www.3dair.co.uk

HRP Group Technical Centre 159 Edinburgh Avenue Slough Trading Estate Slough SL1 4UE Tel: 01753 495700 Fax: 01753 495701 training@hrponline.co.uk

3D Air Sales (Ireland) Ltd Fitzwilliam Business Centre 77 Sir John Rogerson’s Quay Dublin 2

Tel: +353 1 640 1997

ISO9001

MHI Air Conditioning and Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial use air conditioners (including heat pumps).

ISO14001

MHI Air Conditioning and Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001

(2)

Split & Multi Split Systems

Performance Conditions and Terms

2

SRK-HG Wall Fixed Speed

3

SRK-ZJ/ZK Wall Standard Inverter

4

SRK-ZJX Wall Hyper Inverter

5

SRF-ZJX Floor Console Hyper Inv

6

SRR-ZJX Compact Ducted and Controls

7

SCM-ZJ Inverter Multi Systems

8

SCM Indoor Units

9

SCM Combinations

10

SCM Combinations

11

Technical Notes

12

FDTC Compact Cassette

13

FDT Cassette incl. New Hyper

14 - 15

FDEN Ceiling incl. New Hyper

16 - 17

FDUM Ducted incl. Hyper

18 - 19

FDU Ducted High Static incl. Hyper

20 - 21

FDF Floor Vertical incl. Hyper

22 - 23

FD Multi Systems incl Hyper Multi

24 - 27

VRF Inverter Multi Systems

KX Mini 112,140,155

28

KX Side Blow 224, 280, 335

28 - 29

KX 2-Pipe Outdoor Units

28 - 29

KXR 3-Pipe Outdoor Units

30 - 31

KX & KXR Branch Kits

30 - 31

KX6 Indoor Units

32 - 33

KX - New Units, Valve Kits, SAF-DX Unit, & SAF

34

Controls and Accessories

KX Controls and Accessories

35

Air to Water Heat Pumps

Air to Water Heat Pump

36 - 37

Additional Information

Error Codes

38 - 39

MHI Training

40 - 41

Installation Materials - Accessories, Tools & Refrigerant

Installation Accessories from HRP

42 - 45

Tools & Equipment

46

Refrigerants

47

Contents

Welcome

… to the 2011 Price List for Mitsubishi Heavy Industries

air conditioning and heat pump systems.

MHI continues to expand and develop its product range, with higher efficiencies, more technical advantages, and increased benefit for engineers and installers.

Most of the traditional range of SRK fixed speed and Inverter systems is unchanged, with all products having top specification - mostly A/A energy rated - with high grade filtration, deodorising and bacteria filters.

Hyper systems have been introduced with exceptional efficiency, with a record CoP of 5.56

on the SRK20ZJX wall mounted system.

Many of the SRK Inverter heat pump systems can be fitted with the RC-E4 wired remote controller, using the Adaptor SC-BIKN-E.

The FD Series - Cassettes, Ducted, Ceiling systems offer many advantages over competitive products, having a range of compact single fan Inverter outdoor unit for all sizes up to 14kW. There is also the very popular FD Multi Systems (twin/triple/quad) - up to 25kW - ideal for open plan areas, especially retail sites.

FD - Hyper Systems have been extended, offering high CoP, and pipe lengths up to 100 metres. KX - VRF Mini Systems (11.2, 14, 15.5kW) have compact single fan outdoor units, with up to

8 indoor units connected.

The extensive range of KX & KXR 2-pipe and 3-pipe systems are high specification and competitively priced. Valve Kits for Air Handler application are being introduced this year, allowing increased options of applying energy efficient KX systems to other cooling/heating plant.

New this year is the inclusion of Installation Materials, copper tube, insulation, condensate pumps, wall brackets, plus tools and equipment for engineers - all available from HRP Service Centres. With Mitsubishi Heavy Industries we have the most comprehensive and competitive range, with products for nearly every application, and combining this with the huge range of products and materials from HRP, we are able to offer the best service, nationwide, to busy installers and contractors.

MHI Technical Centre

KNOWLEDGE EXPERIENCE UNDERSTANDING

See pages 40 – 41 for details of MHI product training –

Installation Commissioning Troubleshooting Maintenance

1

(3)

• High Wall mounted with three fan speeds • Natural enzyme bacteria filter • Photocatalytic deodorising filter • Maximum pipe length of 15m

• Refrigerant fully charged for 7m pipe length

Selling Category E

INDOOR UNIT c/w IR Controller SRK28HG-S SRK40HG-S

HRP Code 625085 625100 NET Price £90 £102 OUTDOOR UNIT SRC28HG-S SRC40HG-S HRP Code 625045 625060 NET Price £205 £223 SYSTEM Code 624025 624035

SYSTEM NET Price £295 £325

Cooling (Nominal) kW 2.6 3.6

UK Cooling kW 2.5 3.5

UK Sensible Cooling kW 1.9 2.7 E.E.R. (Energy Label) 3.21 (B) 3.21 (B) Heating (Nominal) kW 2.8 3.9 C.O.P (Energy Label) 3.64 (B) 3.41 (B)

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 268 x 790 x 199 268 x 790 x 199

Net Weight kg 8.5 8.5

Air Volume (High Speed) Cooling m3/s 0.14 0.15 Air Volume (High Speed) Heating m3/s 0.17 0.17 Sound Pressure Level (L/M/H) Cooling dB(A) 30 / 33 / 39 34 / 38 / 40 Sound Pressure Level (L/M/H) Heating dB(A) 29 / 33 / 40 34 / 38 / 40

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 540 x 780(+62) x 290 540 x 780(+62) x 290

Net Weight kg 31 38

Sound Pressure Level dB(A) 47 51

ELECTRICAL DATA

Power Source Rating MCB A 25 32 Mains Power To Indoor 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E Running Current - Cooling A 3.7 5.2 Running Current - Heating A 3.5 5.3 Power Input - Cooling kW 0.81 1.12 Power Input - Heating kW 0.77 1.15 Start Current A 17.2 25.2

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 1/2” (12.7) Ref. Max Piping Length m 15 15 Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 10 10 - Outdoor Unit Below Indoor Unit m 10 10 Refrigerant Amount Precharged kg 0.89 1.11 - For Pipe Length Up To m 7 7 Additional Refrigerant g/m <10m = 20 >10m = 30 <10m = 20 >10m = 30

SRK-HG Low Cost systems

High performance fixed speed systems. Please note: Prices are NET.

SRK Fixed Speed not suitable for low ambient cooling operation without control kit. Control: Infra-red control only. Mains Power supply to INDOOR Unit.

A low ambient controller should be fitted for UK cooling operation in low ambient condition, otherwise the warranty may be affected.

Installation Materials

Copper Tube

Wall Brackets

Condensate Pumps

other installation accessories please see pages 42 - 45

SRK-HG Wall Fixed Speed

3

www.3dair .co.uk

Performance Conditions and Terms

2

Nominal & UK Conditions

- Nominal capacities (kW) specified in this price book are calculated under ISO-T1 (JIS) standard conditions as follows:

Cooling: Indoor temperature 27

°

CDB, 19

°

CWB Outdoor temperature 35

°

CDB

Heating: Indoor temperature 20

°

CDB Outdoor temperature 7

°

CDB, 6

°

CWB

- UK cooling capacities (kW) specified in this price book are calculated under the following conditions:

Indoor temperature 23

°

CDB, 16

°

CWB Outdoor temperature 30

°

CDB

Electrical Supplies

Power Source Ratings listed in this publication are for guidance only. Power Source Ratings for Inverter Systems should be based on the Maximum Run Current (shown in brackets in the data tables) and on the relevant Electrical Regulations.

Existing Pipework

Wherever the outdoor units listed below are used, installations can be carried out using existing R22 and R407C pipework according to manufacturer’s instructions. Please contact 3d HRP for information on procedures and training courses.

SRC40 to 60ZJX-S FDC71VNX FDC100 to 140VN(S) FDC100 to 140VN(S)X FDC200 to 250VNS

Engineers must have attended the MHI Training Course Module 8 – please refer to P40

Terms & Conditions

All prices are subject to VAT

Prices are effective from 1st May 2011. Prices are subject to change without notice.

Prices are ex warehouse. Please contact 3D/HRP for delivery charges which may apply. The manufacturer has a continuous programme of product development and reserves the right to change specifications without prior notice.

The information is provide for guidance only, and does not form part of a Contract. Manufacturer’s specifications should be checked prior to ordering.

All goods are supplied subject to HRP & 3D Terms and Conditions – copies available on request. Prices are LIST (except for SRK-HG) and may be subject to agreed trade discounts.

Warranty: 3 years parts only, covers replacement of faulty components provided they are returned within 30 days. Warranty is subject to installation by a qualified engineer in accordance with manufacturer’s instructions, and subject to a maintenance agreement.

(4)

Selling Category C

INDOOR UNIT c/w IR Controller SRK25ZJ-S SRK35ZJ-S SRK50ZJ-S SRK63ZK-S SRK71ZK-S SRK80ZK-S

HRP Code 625083 625098 625108 625520 625530 625540 LIST Price £294 £323 £447 £567 £644 TBC OUTDOOR UNIT SRC25ZJ-S SRC35ZJ-S SRC50ZJ-S SRC63ZK-S SRC71ZK-S SRC80ZK-S HRP Code 625043 625058 625068 625525 625535 625545 LIST Price £443 £514 £587 £785 £1,114 TBC SYSTEM Code 624266 624268 624270 624272 624274 624276

SYSTEM LIST Price £737 £837 £1,034 £1,352 £1,758 TBC

Cooling (Nominal) kW 2.5 3.5 5.0 6.3 7.1 8

Cooling Range kW 1.0 to 2.9 1.0 to 3.8 1.6 to 5.5 2.2 to 7.1 2.2 to 8.0 2.2 to 8.5

UK Cooling Nom kW 2.4 3.3 4.8 6 6.8 7.6

UK Sensible Cooling Nom kW 1.9 2.6 3.4 4.7 5.1 5.7 E.E.R (Energy Label) 4.03 (A) 3.47 (A) 3.23 (B) 3.58 (A) 3.29 (B) 3.02 (B)

Heating (Nominal) kW 3.2 4 5.8 7.1 8 9

Heating Range kW 1.2 to 4.2 1.3 to 4.8 1.6 to 6.6 1.7 to 9.5 1.6 to 10.0 1.7 to 10.5 C.O.P (Energy Label) 4.00 (A) 4.00 (A) 3.65 (B) 3.97 (A) 3.74 (A) 3.53 (B)

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 294 x 798 x 229 294 x 798 x 229 294 x 798 x 229 318 x 1098 x 248 318 x 1098 x 248 318 x 1098 x 248

Net Weight kg 9.5 9.5 9.5 15 15 15

Air Volume (UL – L – M – H) Cooling m3/s na - 0.08 - 0.10 - 0.13 na - 0.08 - 0.11 - 0.17 na - 0.09 - 0.13 - 0.19 0.13 - 0.22 - 0.27 - 0.31 0.13 - 0.23 - 0.29 - 0.33 0.13 - 0.25 - 0.31 - 0.35 Air Volume (UL – L – M – H) Heating m3/s na - 0.09 - 0.11 - 0.18 na - 0.10 - 0.16 - 0.21 na - 0.13 - 0.17 - 0.23 0.21 - 0.24 - 0.30 - 0.34 0.23 - 0.26 - 0.33 - 0.36 0.25 - 0.28 - 0.34 - 0.39 Sound Pressure Level (UL – L – M – H) Cooling dB(A) na / 21 / 28 / 34 na / 22 / 32 / 42 na / 33 / 42 / 48 26 / 37 / 43 / 47 26 / 39 / 45 / 49 26 / 41 / 47 / 50 Sound Pressure Level (UL – L – M – H) Heating dB(A) na / 24 / 31 / 39 na / 25 / 37 / 43 na / 36 / 45 / 48 33 / 36 / 41 / 44 35 / 38 / 43 / 46 37 / 40 / 45 / 48

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 540 x 780(+62) x 290 540 x 780(+62) x 290 640 x 800(+71) x 290 750 x 880(+88) x 340 750 x 880(+88) x 340 750 x 880(+88) x 340

Net Weight kg 32 35 42 57 57 57

Sound Pressure Level dB(A) 49 51 53 50 53 56

ELECTRICAL DATA

Power Source Rating MCB A 16 16 20 25 25 25

Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 3.1 (9) 4.7 (9) 6.8 (14) 8 (17) 9.7 (17) 11.9 (tba) Running Current - Heating Nom (Max) A 3.8 (9) 4.7 (9) 7 (14) 8.1 (17) 9.7 (17) 11.4 (tba) Power Input - Cooling Nom kW 0.62 1.01 1.55 1.76 2.16 2.65 Power Input - Heating Nom kW 0.8 1 1.59 1.79 2.14 2.55

Start Current A 4 5 7 9 10 tba

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)

Ref. Max Piping Length m 15 15 25 30 30 30

Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 10 10 15 20 20 20 - Outdoor Unit Below Indoor Unit m 10 10 15 20 20 20 Refrigerant Amount Precharged kg 0.9 1.1 1.35 1.8 1.8 1.8

- For Pipe Length Up To m 15 15 15 15 15 15

Additional Refrigerant g/m n/a n/a 20 25 25 25

Selling Category C

INDOOR UNIT c/w IR Controller SRK20ZJX-S SRK25ZJX-S SRK35ZJX-S SRK50ZJX-S SRK60ZJX-S

HRP Code 625443 625453 625463 625483 625493 LIST Price £342 £364 £424 £616 £684 OUTDOOR UNIT SRC20ZJX-S SRC25ZJX-S SRC35ZJX-S SRC50ZJX-S SRC60ZJX-S HRP Code 625438 625448 625458 625478 625488 LIST Price £522 £556 £620 £1,030 £1,146 SYSTEM Code 624256 624258 624260 624262 624264

SYSTEM LIST Price £864 £920 £1,044 £1,646 £1,830

Cooling (Nominal) kW 2.0 2.5 3.5 5.0 6

Cooling Range kW 0.9 to 3.1 0.9 to 3.2 0.9 to 4.1 0.7 to 6.2 0.8 to 6.8

UK Cooling Nom kW 1.92 2.4 3.3 4.8 5.7

UK Sensible Cooling Nom kW 1.84 2.3 3.1 3.7 4.2 E.E.R (Energy Label) 5.71 (A) 5.20 (A) 4.14 (A) 3.85 (A) 3.23 (B)

Heating (Nominal) kW 2.5 3.1 4.3 6 6.8

Heating Range kW 0.9 to 4.3 0.9 to 4.7 0.9 to 5.1 0.7 to 8.8 0.8 to 9.7 C.O.P (Energy Label) 5.56 (A) 5.26 (A) 4.48 (A) 4.44 (A) 4.07 (A)

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 309 x 890 x 220 309 x 890 x 220 309 x 890 x 220 309 x 890 x 220 309 x 890 x 220

Net Weight kg 15 15 15 15 15

Air Volume (L/M/H) Cooling m3/s 0.08 – 0.13 – 0.19 0.08 – 0.15 – 0.21 0.08 – 0.16 – 0.23 0.13 – 0.18 – 0.23 0.15 – 0.21 – 0.24 Air Volume (L/M/H) Heating m3/s 0.13 – 0.16 – 0.20 0.13 – 0.17 – 0.22 0.13 – 0.18 – 0.23 0.18 – 0.24 – 0.28 0.18 – 0.25 – 0.28 Sound Pressure Level (L/M/H) Cooling dB(A) 21 / 30 / 39 22 / 31 / 41 22 / 33 / 43 26 / 38 / 45 26 / 38 / 47 Sound Pressure Level (L/M/H) Heating dB(A) 25 / 33 / 38 27 / 34 / 41 27 / 35 / 42 32 / 38 / 45 33 / 39 / 45

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 595 x 780(+62) x 290 595 x 780(+62) x 290 595 x 780(+62) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290

Net Weight kg 38 38 38 43 43

Sound Pressure Level dB(A) 47 47 50 48 51

ELECTRICAL DATA

Power Source Rating MCB A 16 16 16 20 20

Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 1.8 (8) 2.4 (8) 3.8 (8) 5.7 (14) 8.2 (14) Running Current - Heating Nom (Max) A 2.3 (8) 2.9 (8) 4.4 (8) 5.9 (14) 7.3 (14) Power Input - Cooling Nom kW 0.35 0.49 0.85 1.3 1.86 Power Input - Heating Nom kW 0.45 0.6 0.96 1.35 1.67

Start Current A 2.6 2.9 4.4 5.9 8.2

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7)

Ref. Max Piping Length m 15 15 15 30 30

Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 10 10 10 20 20 - Outdoor Unit Below Indoor Unit m 10 10 10 20 20 Refrigerant Amount Precharged kg 1.2 1.2 1.2 1.4 1.4

- For Pipe Length Up To m 15 15 15 15 15

Additional Refrigerant g/m n/a n/a n/a 20 20

• High Wall mounted with three fan speeds • Natural enzyme and Photocatalytic filters • Low ambient operation (cooling) to -15ºC • Maximum pipe length up to 30m (SRK..ZK) • Refrigerant fully charged for 15m pipe length

• High Performance - C.o.P. up to 5.56 • High Wall mounted with three fan speeds • Natural enzyme and Photocatalytic filters • Low ambient operation (cooling) to -15ºC • Negative Ion Generator

NEW

SRK 80 high capacity model (Summer 2011)

SRK-ZJX Wall Mounted Hyper Inverter

5

www.hrponline.co.uk

SRK-ZJ/ZK Wall Mounted Standard Inverter

4

See P7 for additional

(5)

Full range of Installation Accessories available from HRP (see p42 - 45): Copper Tube

Wall Brackets

Condensate Pumps

Selling Category C

INDOOR UNIT c/w IR Controller SRR25ZJ-S SRR35ZJ-S

HRP Code 625330 625336 LIST Price £686 £764 OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S HRP Code 625448 625458 LIST Price £556 £620 SYSTEM Code 624245 624248

SYSTEM LIST Price £1,242 £1,384

Cooling (Nominal) kW 2.5 3.5 Cooling Range kW 0.9 to 3.2 0.9 to 5.1 UK Cooling Nom kW 2.4 3.3 UK Sensible Cooling Nom kW 2 2.5 E.E.R. (Energy Label) 4.31 (A) 3.24 (B) Heating (Nominal) kW 3.4 4.2 Heating Range kW 0.9 to 4.7 0.9 to 5.1 C.O.P (Energy Label) 4.53 (A) 3.82 (A) Operating Range (Outdoor Air) Cooling ºC DB - 5 to 46 Operating Range (Outdoor Air) Heating ºC WB -5 to 21

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 230 x 740 x 455 230 x 740 x 455

Net Weight kg 22 22

Air Volume (L - M - H) Cooling m3/s 0.08 - 0.12 - 0.14 0.09 - 0.13 - 0.15 Air Volume (L - M - H) Heating m3/s 0.11 - 0.15 - 0.17 0.12 - 0.16 - 0.18 Sound Pressure Level (L/M/H) Cooling dB(A) 29 / 35 / 40 30 / 37 / 42 Sound Pressure Level (L/M/H) Heating dB(A) 31 / 38 / 41 32 / 40 / 43

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 595 x 780(+62) x 290 595 x 780(+62) x 290

Net Weight kg 38 38

Sound Pressure Level dB(A) 47 50 ELECTRICAL DATA

Power Source Rating MCB A 16 16 Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E Running Current - Cooling Nom (Max) A 2.8 (8) 4.7 (8) Running Current - Heating Nom (Max) A 3.6 (8) 4.8 (8) Power Input - Cooling Nom kW 0.58 1.08 Power Input - Heating Nom kW 0.75 1.1

Start Current A 4 5

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) Ref. Max Piping Length m 15 15 Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 10 10 - Outdoor Unit Below Indoor Unit m 10 10 Refrigerant Amount Precharged kg 1.2 1.2 - For Pipe Length Up To m 15 15 Additional Refrigerant g/m n/a n/a

• Floor standing or low wall mounted • Pipe length up to 30m on SRF50 • Downward air discharge for heating mode • Refrigerant fully charged for 15m pipe length

• Compact Ducted Unit with three fan speeds • Infra-red Control with 24hr timer • Return Air filter included

• Optional condensate pump and spigot kit • Refrigerant fully charged for 15m pipe length

Selling Category C

INDOOR UNIT c/w IR Controller SRF25ZJX-S SRF35ZJX-S SRF50ZJX-S

HRP Code 625503 625508 625513 LIST Price £633 £711 £715 OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S SRC50ZJX-S HRP Code 625448 625458 625478 LIST Price £556 £620 £1,030 SYSTEM Code 624250 624252 624254

SYSTEM LIST Price £1,189 £1,331 £1,745

Cooling (Nominal) kW 2.5 3.5 5

Cooling Range kW 0.9 to 3.2 0.9 to 4.1 0.7 to 5.5

UK Cooling Nom kW 2.4 3.3 4.8

UK Sensible Cooling Nom kW 2.1 2.6 3.5 E.E.R (Energy Label) 4.80 (A) 3.93 (A) 3.60 (A)

Heating (Nominal) kW 3.4 4.5 6

Heating Range kW 0.9 to 4.7 0.9 to 5.1 0.7 to 7.0 C.O.P (Energy Label) 4.70 (A) 4.00 (A) 3.90 (A) Operating Range (Outdoor Air) Cooling oC DB -15 to 46

Operating Range (Outdoor Air) Heating oC WB -15 to 21

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 600 x 860 x 238 600 x 860 x 238 600 x 860 x 238

Net Weight kg 18 19 19

Air Volume (L/M/H) Cooling m3/s 0.10 – 0.13 – 0.15 0.11 – 0.13 – 0.15 0.11 – 0.16 – 0.19 Air Volume (L/M/H) Heating m3/s 0.11 – 0.1 – 0.18 0.12 – 0.14 – 0.18 0.13 – 0.17 – 0.20 Sound Pressure Level (L/M/H) Cooling dB(A) 26 / 32 / 40 28 / 34 / 41 30 / 39 / 47 Sound Pressure Level (L/M/H) Heating dB(A) 28 / 35 / 40 31 / 36 / 41 32 / 39 / 47

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 595 x 780 (+62) x 290 595 x 780 (+62) x 290 640 x 800(+71) x 290

Net Weight kg 38 38 43

Sound Pressure Level dB(A) 47 50 48

ELECTRICAL DATA

Power Source Rating MCB A 16 16 20 Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 2.5 (8) 3.9 (8) 6.1 (14) Running Current - Heating Nom (Max) A 3.4 (8) 4.9 (8) 6.8 (14) Power Input - Cooling Nom kW 0.52 0.89 1.39 Power Input - Heating Nom kW 0.72 1.12 1.54

Start Current A 3.4 4.9 6.8

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) Ref. Max Piping Length m 15 15 30 Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 10 10 20 - Outdoor Unit Below Indoor Unit m 10 10 20 Refrigerant Amount Precharged kg 1.2 1.2 1.4 - For Pipe Length Up To m 15 15 15 Additional Refrigerant g/m n/a n/a 20

Accessories for SRK-ZJ/ZK/ZJX, SRF & SRR

HRP Code List Price SC-BIKN-E Adaptor for Wired Remote 623463 £151

RC-E4 Remote Control - Wired 623463 £63

PJA504A178XR 6-Wire Adaptor 633086 £15

BBF12 Back Return Filter - SRR 623323 £89

SRR-ZJX Compact Ducted Hyper Inverter

7

SRF-ZJX Floor Console Hyper Inverter

6

www.3dair .co.uk

See P7 for additional Controls and Adaptors

(6)

SRR SCM45, SCM60 SCM80 SCM100, SCM125

Indoor units

Selling Category C OUTDOOR UNIT SCM45ZJ-S SCM60ZJ-S SCM80ZJ-S SCM100ZJ-S SCM125ZJ-S HRP Code 625217 625233 625241 625249 625257 LIST Price £1,119 £1,769 £2,197 TBC TBC Cooling (Nominal) kW 4.5 6 8 TBC TBC Cooling Range kW 1.8 to 6.4 1.8 to 7.5 1.8 to 9.2 TBC TBC E.E.R (Energy Label) 4.33 (A) 4.20 (A) 3.70 (A) TBC TBC

Heating (Nominal) kW 5.6 6.8 9.3 TBC TBC

Heating Range kW 1.4 to 7.4 1.5 to 7.8 1.5 to 9.8 TBC TBC C.O.P (Energy Label) 4.67 (A) 4.50 (A) 4.12 (A) TBC TBC Exterior Dimensions (H x W x D) mm 640 x 850(+65) x 290 640 x 850(+65) x 290 750 x 880(+73) x 340 TBC TBC

Net Weight kg 47 49 62 TBC TBC

Sound Pressure Level dB(A) 49 52 54 TBC TBC Number of Indoor Units Min-Max 1 - 2 2 - 3 2 - 4 TBC TBC

ELECTRICAL DATA

Power Source Rating MCB A 16 20 20

Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz TBC TBC Interconnecting Wires 3 + E (x2) 3 + E (x3) 3 + E (x4) TBC TBC Running Current - Cooling Nom (Max) A 4.6 (14) 6.5 (17) 9.4 (20) TBC TBC Running Current - Heating Nom (Max) A 5.3 (14) 6.8 (17) 10 (20) TBC TBC Power Input - Cooling Nom kW 1.04 1.43 2.16 TBC TBC Power Input - Heating Nom kW 1.2 1.51 2.26 TBC TBC

Start Current A 6 7 10 TBC TBC

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) x 2 1/4” (6.35) x 3 1/4” (6.35) x 4 TBC TBC Gas 3/8” (9.52) x 2 3/8” (9.52) x 3 3/8” (9.52) x 4 TBC TBC Ref. Max Piping Length (Unit/Total) m 25/30 25/40 25/70 TBC TBC Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 15 15 20 TBC TBC - Outdoor Unit Below Indoor Unit m 15 15 20 TBC TBC Refrigerant Amount Precharged kg 1.6 2.2 3.15 TBC TBC

- For Pipe Length Up To m 20 30 40 TBC TBC

Additional Refrigerant g/m 20 20 20TBC TBC TBC Mote: Mains Power to Outdoor Unit. Interconnecting 3core+ E to each Indoor Unit

SRR DUCTED c/w IR Controller SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-S

HRP Code 625330 625336 625346 625354

LIST Price £686 £764 £906 £982

Cooling (Nominal) kW 2.5 3.5 5 6

Heating (Nominal) kW 3.4 4.5 5.8 6.8

Air Volume (Heating - High Speed) m3/s 0.17 0.18 0.22 0.25 Sound Pressure Level (Heating - High Speed) dB(A) 41 43 48 51 Exterior Dimensions (H x W x D) mm 230 x 740 x 455 230 x 740 x 455 230 x 740 x 455 230 x 740 x 455

Net Weight kg 22 22 23 23

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7)

Selling Category C

FDTC CASSETTE c/w

WIRED Controller RC-E4 FDTC25VD FDTC35VD FDTC50VD FDTC60VD

Fascia Panel TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E

Code (Cassette + Fascia + RC-E4 Controller) 622973 622978 622983 622988

LIST Price (Cass. + Fascia + Controller) £738 £742 £765 £817

Cooling (Nominal) kW 2.5 3.5 5 6

Heating (Nominal) kW 3.4 4.5 5.8 6.8 Air Volume (Heating - High Speed) m3/s 0.16 0.17 0.19 0.23 Sound Pressure Level

(Heating - High Speed) dB(A) 38 42 42 46 Exterior Dimensions (H x W x D) Unit mm 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570

Panel mm 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 Net Weight Unit (Fascia Panel) kg 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)

Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7) SRF FLOOR STANDING (c/w IR Controller) SRF25ZJX-S SRF35ZJX-S SRF50ZJX-S Code 625503 625508 625513 LIST Price £633 £711 £715 Cooling (Nominal) kW 2.5 3.5 5 Heating (Nominal) kW 3.4 4.5 5.8 Air Volume (Heating - High Speed) m3/s 0.18 0.18 0.2 Sound Pressure Level

(Heating - High Speed) dB(A) 40 41 47 Exterior Dimensions (H x W x D) mm 600 x 860 x 238 600 x 860 x 238 600 x 860 x 238

Net Weight kg 18 19 19

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) SRK WALL MOUNTED c/w IR Controller SRK25ZJ-S SRK35ZJ-S SRK50ZJ-S Code 625083 625098 625108 LIST Price £294 £323 £447 Cooling (Nominal) kW 2.5 3.5 5 Heating (Nominal) kW 3.4 4.5 5.8 Air Volume (Heating - High Speed) m3/s 0.18 0.21 0.23 Sound Pressure Level

(Heating - High Speed) dB(A) 39 43 45 Exterior Dimensions (H x W x D) mm 294 x 798 x 229 268 x 790 x 199 268 x 790 x 199 Net Weight kg 9.5 9.5 9.5 Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35)

Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7)

Outdoor units

Indoor units

SRKZJ SRKZJ FDTC FDTC SRF

AVAILABLE SUMMER 2011

FDEN50VD Ceiling Suspended & FDUM50VD Ducted Indoor Units for connection to SCM Multi Systems • Simple interconnecting pipe

layout with each Indoor Unit individually connected to Outdoor Unit

• Up to six indoor units on larger systems • Individually controlled indoor units • All indoor units operate in same Mode • Choice of Wall, Cassette, Ducted,

Floor units

SRR

9

www.hrponline.co.uk

SCM-ZJ Inverter Multi Systems

(7)

Outdoor Indoor Unit Type Indoor Cooling Heating Unit SRK FDTC SRR SRF Model kW kW SCM80ZJ-S Indoor A 25 2.37 2.83 Indoor B 25 2.37 2.83 Indoor C 25 2.37 2.83 Indoor D - - -SCM80ZJ-S Indoor A 35 3.21 3.71 Indoor B 25 2.29 2.65 Indoor C 25 2.29 2.65 Indoor D - - -SCM80ZJ-S Indoor A 50 3.90 4.50 Indoor B 25 1.95 2.25 Indoor C 25 1.95 2.25 Indoor D - - -SCM80ZJ-S Indoor A 60 4.25 4.91 Indoor B 25 1.77 2.05 Indoor C 25 1.77 2.05 Indoor D - - -SCM80ZJ-S Indoor A 35 2.87 3.32 Indoor B 35 2.87 3.32 Indoor C 25 2.05 2.37 Indoor D - - -SCM80ZJ-S Indoor A 50 3.55 4.09 Indoor B 35 2.48 2.86 Indoor C 25 1.77 2.05 Indoor D - - -SCM80ZJ-S Indoor A 60 3.90 4.50 Indoor B 35 2.28 2.63 Indoor C 25 1.63 1.88 Indoor D - - -SCM80ZJ-S Indoor A 50 3.12 3.60 Indoor B 50 3.12 3.60 Indoor C 25 1.56 1.80 Indoor D - - -SCM80ZJ-S Indoor A 35 2.60 3.00 Indoor B 35 2.60 3.00 Indoor C 35 2.60 3.00 Indoor D - - -SCM80ZJ-S Indoor A 50 3.25 3.75 Indoor B 35 2.28 2.63 Indoor C 35 2.28 2.63 Indoor D - - -SCM80ZJ-S Indoor A 60 3.60 4.15 Indoor B 35 2.10 2.42 Indoor C 35 2.10 2.42 Indoor D - - -SCM80ZJ-S Indoor A 25 1.98 2.30 Indoor B 25 1.98 2.30 Indoor C 25 1.98 2.30 Indoor D 25 1.98 2.30 SCM80ZJ-S Indoor A 35 2.51 2.93 Indoor B 25 1.80 2.09 Indoor C 25 1.80 2.09 Indoor D 25 1.80 2.09 SCM80ZJ-S Indoor A 50 3.20 3.72 Indoor B 25 1.60 1.86 Indoor C 25 1.60 1.86 Indoor D 25 1.60 1.86 SCM80ZJ-S Indoor A 35 2.33 2.71 Indoor B 35 2.33 2.71 Indoor C 25 1.67 1.94 Indoor D 25 1.67 1.94

Outdoor Indoor Unit Type Indoor Cooling Heating

Unit SRK FDTC SRR SRF Model kW kW SCM45ZJ-S Indoor A 25 2.50 3.40 Indoor B - - -SCM45ZJ-S Indoor A 35 3.50 4.50 Indoor B - - -SCM45ZJ-S Indoor A 25 2.50 3.25 Indoor B 25 2.50 3.25 SCM45ZJ-S Indoor A 35 3.38 3.79 Indoor B 25 2.42 2.71 SCM45ZJ-S Indoor A 35 2.90 3.25 Indoor B 35 2.90 3.25

Outdoor Indoor Unit Type Indoor Cooling Heating

Unit SRK FDTC SRR SRF Model kW kW SCM60ZJ-S Indoor A 25 2.45 3.15 Indoor B 25 2.45 3.15 Indoor C - - -SCM60ZJ-S Indoor A 35 3.38 3.91 Indoor B 25 2.42 2.79 Indoor C - - -SCM60ZJ-S Indoor A 50 4.47 4.73 Indoor B 25 2.23 2.37 Indoor C - - -SCM60ZJ-S Indoor A 60 4.73 5.01 Indoor B 25 1.97 2.09 Indoor C - - -SCM60ZJ-S Indoor A 35 3.30 3.50 Indoor B 35 3.30 3.50 Indoor C - - -SCM60ZJ-S Indoor A 50 3.94 4.18 Indoor B 35 2.76 2.92 Indoor C - - -SCM60ZJ-S Indoor A 60 4.23 4.48 Indoor B 35 2.47 2.62 Indoor C - - -SCM60ZJ-S Indoor A 50 3.35 3.55 Indoor B 50 3.35 3.55 Indoor C - - -SCM60ZJ-S Indoor A 25 2.00 2.27 Indoor B 25 2.00 2.27 Indoor C 25 2.00 2.27 SCM60ZJ-S Indoor A 35 2.51 2.88 Indoor B 25 1.79 2.06 Indoor C 25 1.79 2.06 SCM60ZJ-S Indoor A 50 3.20 3.60 Indoor B 25 1.60 1.80 Indoor C 25 1.60 1.80 SCM60ZJ-S Indoor A 35 2.36 2.62 Indoor B 35 2.36 2.62 Indoor C 25 1.68 1.87 SCM60ZJ-S Indoor A 35 2.20 2.40 Indoor B 35 2.20 2.40 Indoor C 35 2.20 2.40

• Combinations can be selected from the Indoor Unit models listed on Pages 8 - 9.

Inverter multi system combinations SCM

11 10

For SCM 100 & 125 Combinations - please contact 3D/HRP

(8)

* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH. For FDTC Space Collars - please refer to Page 12

RC-E4 Controller with Integral Temperature Sensor

RCH-E3 Simplified Wired Controller (hotel) - also has Integral Sensor

(option)

• 4-way discharge with individual louver control • Fits 600mm x 600mm ceiling grid

• Branch duct facility

• Low ambient operation to -15ºC • Refrigerant charged up to 30m pipe length

Selling Category C

INDOOR UNIT FDTC25VD FDTC35VD FDTC40VD FDTC50VD FDTC60VD

HRP Code 628650 628655 628364 628396 628660

LIST Price £530 £534 £541 £557 £609

FASCIA PANEL TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E TC-PSA-25W-E

HRP Code 627043 627043 627043 627043 627043

LIST Price £145 £145 £145 £145 £145

WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4

HRP Code 623194 623194 623194 623194 623194 LIST Price £63 £63 £63 £63 £63 OUTDOOR UNIT SRC25ZJX-S SRC35ZJX-S SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S HRP Code 625448 625458 625468 625478 625488 LIST Price £556 £620 £823 £1,030 £1,146 HRP SYSTEM Code 622976 622981 622872 622878 622986

SYSTEM LIST Price £1,294 £1,362 £1,572 £1,795 £1,963

Cooling (Nominal) kW 2.6 3.6 4 5 5

Cooling Range kW 0.9 to 3.2 0.9 to 4.1 1.8 to 4.7 2.2 to 5.6 2.2 to 5.6

UK Cooling Nom kW 2.4 3.4 3.8 4.8 5.4

UK Sensible Cooling Nom kW 2.2 2.6 3.2 3.6 3.8 E.E.R (Energy Label) 4.25 (A) 3.36 (A) 3.85 (A) 3.21 (C) 3.21 (C)

Heating (Nominal) kW 3.5 4.3 4.5 5.4 5.4

Heating Range kW 0.9 to 4.7 0.9 to 5.1 2.0 to 5.4 2.5 to 6.3 2.5 to 6.3 C.O.P (Energy Label) 4.11 (A) 3.66 (B) 4.09 (A) 3.72 (A) 3.72 (A)

INDOOR UNIT

Exterior Dimensions (H x W x D) Unit mm 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 248 x 570 x 570 Panel mm 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 35 x 700 x 700 Net Weight Unit (Fascia Panel) kg 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) 15 (3.5) Air Volume* (L - M - H - EH) Cooling m3/s 0.11 - 0.13 - 0.15 - 0.17 0.12 - 0.15 - 0.16 - 0.18 0.12 - 0.15 - 0.19 - 0.23 0.12 - 0.15 - 0.19 - 0.23 0.12 - 0.17- 0.23 - 0.23 Air Volume* (L - M - H - EH) Heating m3/s 0.12 - 0.14 - 0.16 - 0.18 0.13 - 0.15 - 0.17 - 0.19 0.13 - 0.15 - 0.19 - 0.23 0.13 - 0.15 - 0.19 - 0.23 0.13 - 0.17 - 0.23 - 0.23 Sound Pressure Level (L/M/H - EH) Cooling dB(A) 29 / 32 / 36 / 38 30 / 36 / 40 / 41 30 / 36 / 42 / 47 30 / 36 / 42 / 47 30 / 39 / 46 / 47 Sound Pressure Level (L/M/H - EH) Heating dB(A) 29.5 / 33 / 38 / 39 32 / 35 / 42 / 43 32 / 36 / 42 / 47 32 / 36 / 42 / 47 32 / 39 / 46 / 47

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 595 x 780(+62) x 290 595 x 780(+62) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290

Net Weight kg 38 38 45 45 45

Sound Pressure Level dB(A) 47 50 50 54 54

ELECTRICAL DATA

Power Source Rating MCB A 16 16 16 20 20

Mains Power To Outdoor 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz 230v/1ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 2.9 (9) 4.7 (9) 4.6 (12) 6.9 (14) 8.3 (14) Running Current - Heating Nom (Max) A 4 (9) 5.1 (9) 4.9 (12) 6.4 (14) 8.7 (14) Power Input - Cooling Nom kW 0.6 1.07 1.04 1.56 1.99 Power Input - Heating Nom kW 0.84 1.16 1.1 1.45 2.08

Start Current A 4.1 5.3 5.0 5.0 5.0

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) Gas 3/8” (9.52) 3/8” (9.52) 1/2” (12.7) 1/2” (12.7) 1/2” (12.7)

Ref. Max Piping Length m 15 15 30 30 30

Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 10 10 20 20 20 - Outdoor Unit Below Indoor Unit m 10 10 15 15 15 Refrigerant Amount Precharged kg 1.2 1.2 1.4 1.4 1.4

- For Pipe Length Up To m 15 15 15 15 15

Additional Refrigerant g/m n/a n/a 20 20 20 Space Collar - for restricted ceiling height (FDTC Cassettes)

HRP Code List Price 50mm height 623842 £228 100mm height 623858 £193 150mm height 623864 £193 FDTC Space Collars

FDTC Compact Cassette

13

www.hrponline.co.uk

Technical Notes

12

MHI Cassette Systems

FDT Standard & FDTC Compact (600 x 600)

New product features now include Independent Louver Control, allowing air flow patterns to be customised to the size and shape of each conditioned space. This independent control can also help to deal with unwanted drafts.

RC-E4 Multi Function Wired Controller

The RC-E4 (623194) is supplied as standard on all FD split systems. As well as the normal function of Set Temperature adjustment and Fan Speed selection, the wired controller has the following technical advantages:

• Integral temperature sensor, which can be used as an alternative to the the indoor unit return air sensor • Digital display of operating data, including compressor

frequency and speed, valve openings, system pressures and temperatures at various points

• Full diagnosis of system failure - see P38-39 for Error Codes • Facility to eliminate selected display data

• Group Control for up to 16 systems

• The RC-E4 can also be used on all SRK Inverter systems, using Adaptor Kit SC-BIKN-E

RCH-E3 Simplified Controller is an alternative wired controller

designed for hotel rooms, offices and other sreas, where full functions are not required.

6-Way Adaptor CnT

This low cost Adaptor(633086) allows on/off (12v) switching via a volt free contact. It plugs into the indoor unit pcb on FD series indoor units, including all of the KX range. It also plugs into the SC-BIKN-E adaptor for SRK-JZ/ZK/ZJX, SRF & SRR. The adaptor allows low voltage output signals to indicate: Cooling, Heating, and Common Fault signal.

The position of each louver can be set on the Wired Controller RC-E4

(9)

Option Standard

HRP Code List Price 6-Way Adaptor for Timeclock & BMS 633086 £12

Remote Controller & Receiver Kit 623203 £129

Network Adaptor SC-ADN-E 623384 £94 Accessories

Space Collar - for restricted ceiling height - FDT Cassettes only HRP Code List Price 50mm height 629802 £237

100mm height 629818 £264

150mm height 629826 £283

Condensing Unit Drain Kit

Elbow & Grometts 626990 £8

Selling Category - B

FDT MULTI SPLIT Systems up to 25kW

- please refer to P24

Installation Accessories

-

Copper Tube

Insulation

Pipe Supports

Wall Brackets

Condensate Pumps & Hose

Isolators

Cables

- please see P42

TECHNICAL NOTES

Group Control is possible (up to 16 systems) using one

RC-E4 Remote Controller.

RC-E4 Remote Controller includes internal temperature

sensor, which can be used as an alternative to the unit return air sensor.

FDT Hyper 1-Phase (3ph - p.o.a.) FDT 3-Phase Systems

FDT Cassette Hyper Inverter Systems

INDOOR UNIT FDT40VD FDT50VD FDT60VD FDT71VD FDT100VD FDT125VD FDT140VD FDT100VD FDT125VD FDT140VD

HRP Code 628380 628412 628428 628444 628460 628476 628492 628460 628476 628492

LIST Price £535 £540 £618 £691 £824 £993 £1,158 £824 £993 £1,158

FASCIA PANEL T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E

HRP Code 623209 623209 623209 623209 623209 623209 623209 623209 623209 623209

LIST Price £151 £151 £151 £151 £151 £151 £151 £151 £151 £151

WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4

HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194 623194

LIST Price £63 £63 £63 £63 £63 £63 £63 £63 £63 £63

OUTDOOR UNIT SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)

HRP Code 625468 625478 625488 628060 628069 628101 628133 628085 628117 628149

LIST Price £823 £1,030 £1,146 £1,523 £1,784 £1,928 £2,221 £1,784 £1,928 £2,221

HRP SYSTEM Code 622068 622082 622088 622092 622098 622108 622118 622102 622112 622128

SYSTEM LIST Price £1,572 £1,784 £1,978 £2,428 £2,822 £3,135 £3,593 £2,822 £3,135 £3,593

Cooling (Nominal) kW 4 5 5.6 7.1 10 12.5 14 10 12.5 14

Cooling Range kW 1.1 to 4.7 1.1 to 5.6 1.1 to 6.3 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5

UK Cooling Nom kW 3.8 4.8 5.4 6.7 9.4 11.8 12.7 9.4 11.8 12.7

UK Sensible Cooling Nom kW 3.3 3.8 4.6 5.4 7.1 8.5 9.4 7.1 8.5 9.4

E.E.R (Energy Label) 4.30 (A) 3.88 (A) 3.68 (A) 3.48 (A) 3.62 (A) 3.09 (B) 2.81 (C) 3.62 (A) 3.09 (B) 2.81 (C)

Heating (Nominal) kW 4.5 5.4 6.7 8 11.2 14 16 11.2 14 16

Heating Range kW 0.6 to 5.4 0.6 to 6.3 0.6 to 7.1 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 C.O.P (Energy Label) 4.25 (A) 4.19 (A) 3.94 (A) 4.12 (A) 4.09 (A) 3.71 (A) 3.50 (B) 4.09 (A) 3.71 (A) 3.50 (B)

INDOOR UNIT

Exterior Dimensions (H x W x D) Unit mm 246 x 840 x 840 246 x 840 x 840 246 x 840 x 840 246 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 Panel mm 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 Net Weight Unit (Fascia Panel) kg 22 (5.5) 22 (5.5) 24 (5.5) 24 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) 27 (5.5) Air Volume (L - M - H -EH)* m3/s 0.23 - 0.27 - 0.30 - 0.33 0.23 - 0.27 - 0.30 - 0.33 0.23 - 0.27 - 0.30 - 0.33 0.28 - 0.32 - 0.35 - 0.47 0.33 - 0.40 - 0.45 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.33 - 0.40 - 0.45 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.38 - 0.45 - 0.50 - 0.62 Sound Pressure Level (L / M /H / EH) dB(A) 30 / 31 / 33 / 39 30 / 31 / 33 / 39 30 / 31 / 33 / 39 31 / 33 / 35 / 46 35 / 37 / 40 / 51 37 / 40 / 42 / 51 38 / 41 / 43 / 51 35 / 37 / 40 / 51 37 / 40 / 42 / 51 38 / 41 / 43 / 51

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290 750 x 880(+88) x 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370

Net Weight kg 45 45 45 60 81 81 81 83 83 83

Sound Pressure Level dB(A) 50 54 54 51 49 51 51 49 51 51

ELECTRICAL DATA

Power Source Rating MCB A 16 20 20 25 32 32 32 20 per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E

Running Current - Cooling Nom (Max) A 4.1 (12) 5.7 (15) 7.0 (15) 9.1 (24) 12.1 (24) 17.6 (24) 22 (24) 4.2 (15) per phase 5.9 (15) per phase 7.4 (15) per phase Running Current - Heating Nom (Max) A 5.2 (12) 5.7 (15) 8.2 (15) 8.7 (24) 12 (24) 16.6 (24) 20.2 (24) 4.2 (15) per phase 5.5 (15) per phase 6.7 (15) per phase Power Input - Cooling Nom kW 0.93 1.29 1.52 2.04 2.76 4.05 4.98 2.76 4.05 4.98 Power Input - Heating Nom kW 1.06 1.29 1.7 1.94 2.74 3.77 4.57 2.74 3.77 4.57

Start Current A 5 5 5 5 5 5 5 5 per phase 5 per phase 5 per phase

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) Gas 1/2” (12.7) 1/2” (12.7) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)

Ref. Max Piping Length m 30 30 30 50 50 50 50 50 50 50

Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 20 20 20 30 30 30 30 30 30 30

- Outdoor Unit Below Indoor Unit m 20 20 20 15 15 15 15 15 15 15

Refrigerant Amount Precharged kg 1.5 1.5 1.5 2.95 3.8 3.8 3.8 3.8 3.8 3.8

- For Pipe Length Up To m 15 15 15 30 30 30 30 30 30 30

Additional Refrigerant g/m 20 20 20 60 60 60 60 60 60 60

FDT100VD FDT125VD FDT140VD

628460 628476 628492

£824 £993 £1,158

T-PSA-3AW-E T-PSA-3AW-E T-PSA-3AW-E

623209 623209 623209

£151 £151 £151

RC-E4 RC-E4 RC-E4

623194 623194 623194 £63 £63 £63 FDC100VNX FDC125VNX FDC140VNX 628205 628185 628195 £2,087 £2,294 £2,643 622095 622946 622951 £3,125 £3,501 £4,015 10 12.5 14 4.0 to 11.2 5.0 to 14.0 5.0 to 16.0 9.5 11.8 13.2 8.3 9.6 10.2 4.00 (A) 3.81 (A) 3.34 (A)

11.2 14 16

4.0 to 12.5 4.0 to 17.0 4.0 to 18.0 4.34 (A) 4.08 (A) 3.81 (A)

298 x 840 x 840 298 x 840 x 840 298 x 840 x 840 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 27 (5.5) 27 (5.5) 27 (5.5) 0.33 - 0.40 - 0.45 - 0.62 0.38 - 0.45 - 0.50 - 0.62 0.38 - 0.45 - 0.50 - 0.62 35 / 37 / 40 / 51 37 / 40 / 42 / 51 38 / 41 / 43 / 51 1300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370 105 105 105 50 50 52 32 32 32 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 11.1 (24) 14.6 (24) 18.6 (26) 11.4 (24) 15.2 (24) 18.6 (26) 2.5 3.28 4.19 2.58 3.43 4.2 5 per phase 5 per phase 5 per phase

3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 100 100 100 30 30 30 15 15 15 4.5 4.5 4.5 30 30 30 60 60 60

• 4-way discharge with individual louver control • Wired Contrller standard, Infra-red option • Branch duct facility and fresh air inlet • Low ambient operation to -15ºC • Refrigerant charged up to 30m pipe length

Selling Category -B FDT 1-Phase Systems

* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.

NEW

Pipe length up to 100m

on Hyper Systems 100, 125, 140

www.3dair .co.uk

14 15

(10)

Condensing Unit Drain Kit

Elbow & Grometts 626990 £8

FDEN Hyper 1-Phase (3ph - p.o.a.) FDEN 3-Phase Systems

Selling Category -B FDEN 1-Phase Systems

(option)

• Wired Controller standard, Infra-red option • Slim design - 210mm on most models • Low ambient operation to -15ºC • Refrigerant charged up to 30m pipe length

INDOOR UNIT FDEN40VD FDEN50VD FDEN60VD FDEN71VD FDEN100VD FDEN125VD FDEN140VD FDEN100VD FDEN125VD FDEN140VD

HRP Code 628308 628316 628324 628332 628340 628348 628356 628340 628348 628356

LIST Price £636 £645 £714 £826 £963 £1,300 £1,496 £963 £1,300 £1,496

WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4

HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194 623194

LIST Price £63 £63 £63 £63 £63 £63 £63 £63 £63 £63

OUTDOOR UNIT SRC40ZJX-S SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)

HRP Code 625468 625478 625488 628060 628069 628101 628133 628085 628117 628149

LIST Price £823 £1,030 £1,146 £1,523 £1,784 £1,928 £2,221 £1,784 £1,928 £2,221

HRP SYSTEM Code 622002 622008 622012 622018 622028 622038 622048 622032 622042 622052

SYSTEM LIST Price £1,522 £1,738 £1,923 £2,412 £2,810 £3,291 £3,780 £2,810 £3,291 £3,780

Cooling (Nominal) kW 4 5 5.6 7.1 10 12.5 14 10 12.5 14

Cooling Range kW 1.1 to 4.7 1.1 to 5.6 21.1 to 6.3 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5

UK Cooling Nom kW 3.8 4.8 5.4 6.7 9.4 11.8 12.7 9.4 11.8 12.7

UK Sensible Cooling Nom kW 3 3.3 4.6 5.1 6.8 8.2 8.5 6.8 8.2 8.5

E.E.R (Energy Label) 3.92 (A) 3.27 (B) 3.15 (B) 3.36 (A) 3.51 (A) 2.80 (D) 2.41 (E) 3.51 (A) 2.80 (D) 2.41 (E)

Heating (Nominal) kW 4.5 5.4 6.7 8 11.2 14 16 11.2 14 16

Heating Range kW 0.6 to 5.4 2.5 to 6.3 0.6 to 7.1 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 C.O.P (Energy Label) 4.09 (A) 3.70 (A) 3.58 (B) 3.79 (A) 3.77 (A) 3.43 (B) 3.25 (C) 3.77 (A) 3.43 (B) 3.25 (C)

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 210 x 1070 x 690 210 x 1070 x 690 210 x 1320 x 690 210 x 1320 x 690 250 x1620 x 690 250 x 1620 x 690 250 x 1620 x 690 250 x1620 x 690 250 x 1620 x 690 250 x 1620 x 690

Net Weight kg 28 28 37 37 49 49 49 49 49 49

Air Volume* (L - M - H -EH) m3/s 0.12 - 0.15 - 0.18 - 0.22 0.12 - 0.15 - 0.18 - 0.22 0.20 - 0.23 - 0.30 - 0.37 0.20 - 0.23 - 0.30 - 0.37 0.35 - 0.38 - 0.43 - 0.47 0.38 - 0.43 - 0.48 - 0.53 0.38 - 0.43 - 0.48 - 0.53 0.35 - 0.38 - 0.43 - 0.47 0.38 - 0.43 - 0.48 - 0.53 0.38 - 0.43 - 0.48 - 0.53 Sound Pressure Level (L / M /H / EH) dB(A) 37 / 38 / 39 / 46 37 / 38 / 39 / 46 38 / 39 / 41 / 50 38 / 39 / 41 / 51 39 / 41 / 44 / 46 43 / 44 / 46 / 50 43 / 44 / 46 / 50 39 / 41 / 44 / 46 43 / 44 / 46 / 50 43 / 44 / 46 / 50

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290 640 x 800(+71) x 290 640 x 800(+71) x 290 750 X 880(+88) X 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370

Net Weight kg 45 45 45 60 81 81 81 83 83 83

Sound Pressure Level dB(A) 50 54 54 51 49 51 51 49 51 51

ELECTRICAL DATA

Power Source Rating MCB A 16 20 20 25 32 32 32 20 per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 4.7 (12) 7.1 (14) 8.7 (14) 9.4 (17) 12.5 (24) 19.5 (24) 25.6 (26) 4.2 (15) per phase 6.8 (15) per phase 8.6 (15) per phase Running Current - Heating Nom (Max) A 5.1 (12) 7.0 (14) 9.4 (14) 9.4 (17) 13 (24) 17.9 (24) 22.1 (26) 4.3 (15) per phase 6.3 (15) per phase 7.2 (15) per phase Power Input - Cooling Nom kW 1.02 1.53 1.78 2.11 2.85 4.45 5.8 2.85 4.45 5.8 Power Input - Heating Nom kW 1.1 1.46 1.87 2.11 2.97 4.08 4.92 2.97 4.08 4.92

Start Current A 5 5 5 5 5 5 5 5 per phase 5 per phase 5 per phase

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 1/4” (6.35) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) Gas 1/2” (12.7) 1/2” (12.7) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)

Ref. Max Piping Length m 30 30 30 50 50 50 50 50 50 50

Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 20 20 20 30 30 30 30 30 30 30

- Outdoor Unit Below Indoor Unit m 20 20 20 15 15 15 15 15 15 15

Refrigerant Amount Precharged kg 1.5 1.5 1.5 2.95 3.8 3.8 3.8 3.8 3.8 3.8

- For Pipe Length Up To m 15 15 15 30 30 30 30 30 30 30

Additional Refrigerant g/m 20 20 20 60 60 60 60 60 60 60

FDEN100VD FDEN125VD FDEN140VD

628340 628348 628356

£963 £1,300 £1,496

RC-E4 RC-E4 RC-E4

623194 623194 623194 £63 £63 £63 FDC100VNX FDC125VNX FDC140VNX 628205 628185 628195 £2,087 £2,294 £2,643 622023 622956 622961 £3,113 £3,657 £4,202 10 12.5 14 4.0 to 11.2 5.0 to 14.0 5.0 to 16.0 9.5 11.8 13.2 6.8 8.2 8.7 3.57 (A) 3.24 (B) 2.81 (C) 11.2 14 16 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 3.89 (A) 3.71 (A) 3.41 (B) 250 x1620 x 690 250 x 1620 x 690 250 x 1620 x 690 49 49 49 0.35 - 0.38 - 0.43 - 0.47 0.38 - 0.43 - 0.48 - 0.53 0.38 - 0.43 - 0.48 - 0.53 39 / 41 / 44 / 46 43 / 44 / 46 / 50 43 / 44 / 46 / 50 1300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370 105 105 105 50 50 52 32 32 32 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 12.4 (24) 17.1 (26) 22.1 (26) 12.8 (24) 16.7 (26) 20.8 (26) 2.8 3.86 4.98 2.88 3.77 4.69 24 26 26 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 50 50 50 30 30 30 15 15 15 4.5 4.5 4.5 30 30 30 0 60 60

TECHNICAL NOTE: The indoor unit comes set-up for use with an IR controller.

When using the RC-E4 or RCH-E3 wired controller, please disconnect the IR PCB from the AB connection on the indoor unit.

* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.

HRP Code List Price 6-Way Adaptor for Timeclock & BMS 633086 £12

Remote Control Infrared RCN-E1R 632196 £63

Network Adaptor SC-ADN-E 623384 £94 Accessories

FDEN MULTI SPLIT Systems up to 25kW

- please refer to P24

Installation Accessories

-•

Copper Tube

Insulation

Pipe Supports

Wall Brackets

Condensate Pumps & Hose

Isolators

Cables

- please see P42

TECHNICAL NOTES

Group Control is possible (up to 16 systems) using one

RC-E4 Remote Controller.

RC-E4 Remote Controller includes internal temperature

sensor, which can be used as an alternative to the unit return air sensor.

NEW

Pipe length up to 100m

on Hyper Systems 100, 125, 140

17

www.hrponline.co.uk

FDEN Ceiling Inverter Systems

16

(11)

* If wireless remote controller is used, only 3 fan speeds are available: LOW/MED/HIGH.

Return Air Filter Kit Not included.

FDUM100VD FDUM125VD FDUM140VD

628532 628540 628548

£1,076 £1,268 £1,280

RC-E4 RC-E4 RC-E4

623194 623194 623194 £63 £63 £63 FDC100VNX FDC125VNX FDC140VNX 628205 628185 628195 £2,087 £2,294 £2,643 622145 622966 622971 £3,226 £3,625 £3,986 10 12.5 14 4.0 to 11.2 5.0 to 14.0 5.0 to 16.0 9.5 11.8 13.2 7.8 9 9.6 3.68 (A) 3.45 (A) 3.23 (B) 11.2 14 16 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.04 (A) 3.71 (A) 3.41 (B) 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 60 / 90 60 / 85 60 / 85 4 x 200 4 x 200 4 x 200 59 59 59 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 32 / 35 / 37 / 41 32 / 36 / 38 / 41 32 / 36 / 38 / 41 1300 x 970 x 370 1300 x 970 x 370 1300 x 970 x 370 105 105 105 50 50 52 32 32 32 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 3 + E 3 + E 3 + E 12.1 (24) 16.1 (26) 19.3 (26) 13.1 (24) 16.7 (26) 20.8 (26) 2.72 3.62 4.34 2.95 3.77 4.69 5 5 5 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 100 100 100 30 30 30 15 15 15 4.5 4.5 4.5 30 30 30 60 60 60

• Medium static horizontal ducted units • Condensate lift pump included • Option of bottom horizontal return air • Low ambient operation to -15ºC • Refrigerant charged up to 30m pipe length

FDUM 3-Phase Systems

Selling Category -B FDUM 1-Phase Systems FDUM Hyper 1-Phase (3ph - p.o.a.)

INDOOR UNIT FDUM50VD FDUM60VD FDUM71VD FDUM100VD FDUM125VD FDUM140VD FDUM100VD FDUM125VD FDUM140VD

HRP Code 628508 628516 628524 628532 628540 628548 628532 628540 628548

LIST Price £513 £574 £769 £1,076 £1,268 £1,280 £1,076 £1,268 £1,280

WIRED CONTROLLER RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4 RC-E4

HRP Code 623194 623194 623194 623194 623194 623194 623194 623194 623194

LIST Price £63 £63 £63 £63 £63 £63 £63 £63 £63

OUTDOOR UNIT SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VN FDC140VN FDC100VS (3 phase) FDC125VS (3 phase) FDC140VS (3 phase)

HRP Code 625478 625488 628060 628069 628101 628133 628085 628117 628149

LIST Price £1,030 £1,146 £1,523 £1,784 £1,928 £2,221 £1,784 £1,928 £2,221

HRP SYSTEM Code 622120 622138 622142 622148 622158 622168 622152 622162 622172

SYSTEM LIST Price £1,606 £1,783 £2,355 £2,923 £3,259 £3,564 £2,923 £3,259 £3,564

Cooling (Nominal) kW 5 5.6 7.1 10 12.5 14 10 12.5 14

Cooling Range kW 1.1 to 5.6 1.1 to 6.3 3.2 to 8.0 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5 4.0 to 11.2 5.0 to 14.0 5.0 to 14.5

UK Cooling Nom kW 4.8 5.4 6.7 9.4 11.8 12.7 9.4 11.8 12.7

UK Sensible Cooling Nom kW 3.7 4.4 5.2 7.8 9 9.4 7.8 9 9.4

E.E.R (Energy Label) 3.29 (B) 3.09 (B) 3.32 (A) 3.57 (A) 3.10 (B) 2.83 (C) 3.57 (A) 3.10 (B) 2.83 (C) 3.57 (A)

Heating (Nominal) kW 5.4 6.7 8 11.2 14 16 11.2 14 16

Heating Range kW 2.5 to 6.3 3.1 to 7.1 3.6 to 9.0 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 4.0 to 12.5 4.0 to 16.0 4.0 to 16.5 C.O.P (Energy Label) 3.83 (A) 3.42 (B) 3.70 (A) 4.04 (A) 3.68 (B) 3.26 (C) 4.04 (A) 3.68 (B) 3.26 (C)

INDOOR UNIT

Exterior Dimensions (H x W x D) mm 299 x 750 x 635 299 x 950 x 635 299 x 950 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 350 x 1370 x 635 External Static Pressure (Standard / Max) Pa 50 / 85 50 / 85 50 / 85 60 / 90 60 / 85 60 / 85 60 / 90 60 / 85 60 / 85 No. Of Supply Air Spigots mm 2 x 200 3 x 200 3 x 200 4 x 200 4 x 200 4 x 200 4 x 200 4 x 200 4 x 200

Net Weight kg 34 40 40 59 59 59 59 59 59

Air Volume* (L - M - H -EH) m3/s 0.18 - 0.20 - 0.22 - 0.23 0.23 - 0.25 - 0.27 - 0.30 0.25 - 0.30 - 0.33 - 0.38 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 0.37 - 0.42 - 0.47 - 0.57 Sound Pressure Level (L / M /H / EH) dB(A) 28 / 31 / 34 / 35 28 / 31 /34 / 38 29 / 32 / 35 / 38 32 / 35 / 37 / 41 32 / 36 / 38 / 41 32 / 36 / 38 / 41 32 / 35 / 37 / 41 32 / 36 / 38 / 41 32 / 36 / 38 / 41

OUTDOOR UNIT

Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290 640 x 800(+71) x 290 750 x 880(+88) x 340 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370 845 x 970 x 370

Net Weight kg 45 45 60 81 81 81 83 83 83

Sound Pressure Level dB(A) 54 54 51 49 51 51 49 51 51

ELECTRICAL DATA

Power Source Rating MCB A 20 20 25 32 32 32 20 per phase 20 per phase 20 per phase Mains Power To Outdoor 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 230V/1ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz 415V/3ph/50Hz Interconnecting Wires 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E 3 + E Running Current - Cooling Nom (Max) A 6.7 (14) 8.2 (14) 9.5 (17) 12.5 (24) 18.3 (24) 23.2 (26) 4.2 (15) per phase 6.1 (15) per phase 7.6 (15) per phase Running Current - Heating Nom (Max) A 6.3 (14) 9.0 (14) 9.6 (17) 12.4 (24) 17.0 (24) 22.3 (26) 4.1 (15) per phase 5.7 (15) per phase 7.4 (15) per phase Power Input - Cooling Nom kW 1.52 1.81 2.14 2.8 4.03 4.95 2.8 4.03 4.95 Power Input - Heating Nom kW 1.41 1.96 2.16 2.77 3.8 4.89 2.77 3.8 4.89

Start Current A 5 5 5 5 5 5 5 per phase 5 per phase 5 per phase

INSTALLATION/REFRIGERANT

Ref. Piping Size o.d ins (mm) Liquid 1/4” (6.35) 1/4” (6.35) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) 3/8” (9.52) Gas 1/2” (12.7) 1/2” (12.7) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88) 5/8” (15.88)

Ref. Max Piping Length m 30 30 50 50 50 50 50 50 50

Vertical Height Difference (Max)

- Outdoor Unit Above Indoor Unit m 20 20 30 30 30 30 30 30 30

- Outdoor Unit Below Indoor Unit m 15 15 15 15 15 15 15 15 15

Refrigerant Amount Precharged kg 1.5 1.5 2.95 3.8 3.8 3.8 3.8 3.8 3.8

- For Pipe Length Up To m 15 15 30 30 30 30 30 30 30

Additional Refrigerant g/m 20 20 60 60 60 60 60 60 60

HRP Code List Price 6-Way Adaptor for Timeclock & BMS 633086 £12

Remote Control (IR) & Receiver Kit 623452 £161

Network Adaptor SC-ADN-E 623384 £94

Filter kit FDUM 50 UM-FL1E 624312 £89

Filter kit FDUM 60 - 71 UM-FL2E 624314 £89

Filter kit FDUM 100 - 140 UM-FL3E 624316 £89 Accessories

FDUM MULTI SPLIT Systems up to 25kW

- please refer to P24

Technical Note:

When designing ductwork and filtration, always refer to manufacturer's Fan Curves.

Installation Accessories

-•

Copper Tube

Insulation

Pipe Supports

Wall Brackets

Condensate Pumps & Hose

Isolators

Cables

- please see P42

TECHNICAL NOTES

Group Control is possible (up to 16 systems) using one

RC-E4 Remote Controller.

RC-E4 Remote Controller includes internal temperature

sensor, which can be used as an alternative to the unit return air sensor.

NEW

Pipe length up to 100m

on Hyper Systems 100, 125, 140 See opposite page

for Filters/Frames

19

FDUM Ducted Inverter Systems

18

FDUM Ducted Hyper Inverter Systems

Figure

Updating...

References

Updating...

Related subjects :