• No results found

ABB-Welcome 83325/2-5..

N/A
N/A
Protected

Academic year: 2021

Share "ABB-Welcome 83325/2-5.."

Copied!
8
0
0

Loading.... (view fulltext now)

Full text

(1)

ABB-Welcome

Pos : 2 /Di nA4 - Anleit ung en O nline/I nhalt /KN X/D oorEntr y/ 83325- 2/Tit elbl att - 83325-2 - ABB @ 19\ mod_1323167925512_15.doc x @ 110957 @ @ 1

DE

EN

FR

NL

RU

PL

NO

SW

FI

IT

ES

CN

83325/2-5..

Videoverteiler Außen

Outdoor video distributor

Distributeur vidéo extérieur

Videoverdeler buiten

Внешний

видеораспределитель

Rozdzielacz wideo

zewnętrzny

Videofordeler utendørs

Videofördelare, yttre

Videojakaja, ulko

Splitter video esterno

Distribuidor de video

exterior

室外视频分配器

(2)

ABB-Welcome

Pos : 4 / Busch-J aeger (Neus trukt ur)/M odul-Str ukt ur/O nline-Dokumentation/I nhal ts verz eic hnis (--> Für alle D okument e <--)/I nhalts verz eichnis @ 19\ mod_1320649044386_15. doc x @ 109653 @ @ 1

1

Safety ... 3

2

Intended use ... 3

3

Environment ... 3

3.1

ABB devices ... 3

4

User Manual ... 3

5

Technical data ... 4

6

Mounting / Installation ... 5

6.1

Requirements for the electrician ... 5

6.2

General installation instructions ... 5

6.3

Mounting ... 6

6.4

Connection ... 6

(3)

ABB-Welcome

Safety

| 0073-1-7520

— 3 —

Pos : 6 / Busch-J aeger (Neus trukt ur)/M odul-Str ukt ur/O nline-Dokumentation/Ü bers chrift en (--> Für alle Dokumente <--)/1. Ebene/S - T/ Sicherheit @ 18\ mod_1302612791790_15. doc x @ 103357 @ 1 @ 1

1

Safety

Pos : 7 / Busch-J aeger (Neus trukt ur)/M odul-Str ukt ur/O nline-Dokumentation/ Sicherheit (--> Für all e D okument e <--)/Warnhi nweis e/ Sicherheit - 230 V @ 18\ mod_1302606816750_15. doc x @ 103308 @ @ 1

Warning

Electric voltage!

Risk of death and fire due to electrical voltage of 230 V.

– Work on the 230V supply system may only be performed by authorised electricians!

– Disconnect the mains power supply prior to installation and/or disassembly!

Pos : 8 / Busch-J aeger (Neus trukt ur)/M odul-Str ukt ur/O nline-Dokumentation/Ü bers chrift en (--> Für alle Dokumente <--)/1. Ebene/A - F/ Bes ti mmungsgemäßer Gebrauc h @ 18\mod_1302763321316_15.doc x @ 103483 @ 1 @ 1

2

Intended use

Pos : 9 /Di nA4 - Anleit ung en O nline/I nhalt /KN X/D oorEntr y/ 83325- 2/ Bes timmungsgemaess er G ebrauc h - 83325- 2-500 @ 19\ mod_1323167484272_15. doc x @ 110948 @ @ 1

The 83325/2-500 video distributor is an integral part of the ABB-Welcome door communication system and

operates exclusively with components from this system. The device must only be installed on mounting rails

according to DIN EN 500022.

Pos : 10 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Übersc hrift en (--> Für alle D okument e <--)/1. Ebene/U - Z/U mwelt @ 18\ mod_1302614158967_15. doc x @ 103383 @ 1 @ 1

3

Environment

Pos : 11 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/U mwel t (--> Für alle D okument e <--)/Hinweis e/Hi nweis - U mwelt - Hinweis Elektrog erät e @ 18\mod_1302763973434_15. doc x @ 103500 @ @ 1

Consider the protection of the environment!

Used electric and electronic devices must not be disposed of with domestic waste.

– The device contains valuable raw materials which can be recycled. Therefore, dispose of the

device at the appropriate collecting depot.

Pos : 12 /DinA4 - Anl eitungen Onli ne/Ueberschrif ten/ 2. /ABB G eraet e @ 19\ mod_1323162843832_15.doc x @ 110875 @ 2 @ 1

3.1

ABB devices

Pos : 13 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/U mwel t (--> Für alle D okument e <--)/Hinweis e/Hi nweis - U mwelt - ABB El ektr ogeräte @ 19\ mod_1323162745839_15. doc x @ 110867 @ @ 1

All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always

dispose of the packaging material and electric devices and their components via the authorized collecting depots

and disposal companies.

ABB products meet the legal requirements, in particular the laws governing electronic and electrical devices and

the REACH ordinance.

(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)

(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Pos : 14 /DinA4 - Anl eitungen Onli ne/Ueberschrif ten/ 1. /Anwender handbuc h @ 19\ mod_1309347227593_15.doc x @ 107473 @ 1 @ 1

4

User Manual

Pos : 15 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/Syst emhandbuc h/ Anwender handbuc h - ABB @ 19\ mod_1323163157997_15.doc x @ 110883 @ @ 1

Detailed information for planning ABB-Welcome systems is contained in the user manual. Download at

www.Busch-Jaeger.com.

Pos : 16 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Steuermodul e - Onli ne-D okument ation (--> F ür all e D okument e <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\ mod_1268898668093_0.doc x @ 52149 @ @ 1

(4)

ABB-Welcome

Technical data

Pos : 17 /DinA4 - Anl eitungen Onli ne/Ueberschrif ten/ 1. /Tec hnisc he D at en @ 18\ mod_1302615863001_15.doc x @ 103416 @ 1 @ 1

5

Technical data

Pos : 18 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/83325-2/Technisc he Daten - 83325- 2 @ 18\ mod_1303218165047_15.doc x @ 103876 @ @ 1

Designation

Value

Operating temperature (EN

50486)

-5

to +45

Storage temperature

-20°C – +70°C

Protection

IP 20

Single-wire clamps

2 x 0.6 mm² – 2 x 1 mm²

Fine-wire clamps

2 x 0.6 mm² – 2 x 0.75 mm²

Volume

Maximum 80 dB

Bus voltage

28 V- ±2 V

Size

2 TE

Pos : 19 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Steuermodul e - Onli ne-D okument ation (--> F ür all e D okument e <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\ mod_1268898668093_0.doc x @ 52149 @ @ 1

(5)

ABB-Welcome

Mounting / Installation

| 0073-1-7520

— 5 —

Pos : 20 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Übersc hrift en (--> Für alle D okument e <--)/1. Ebene/M - O /Mont age / I nst allation @ 18\ mod_1302613966111_15.doc x @ 103373 @ 1 @ 1

6

Mounting / Installation

Pos : 21 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Sic herheit (--> Für alle Dokumente <--)/Warnhinweis e/Sic herheit - Ni eders pannungs- und 230 V-Leit ungen @ 18\ mod_1302617821491_15. doc x @ 103465 @ @ 1

Warning

Electric voltage!

Risk of death and fire due to electrical voltage of 230 V.

– Low-voltage and 230 V cables must not be installed together in a flush-mounted socket!

In case of a short-circuit there is the danger of a 230 V load on the low-voltage line.

Pos : 22 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Sic herheit (--> Für alle Dokumente <--)/Warnhinweis e/Sic herheit - F ac hkennt niss e @ 18\ mod_1302774384017_15.doc x @ 103564 @ 2 @ 1

6.1

Requirements for the electrician

Warning

Electric voltage!

Install the device only if you have the necessary electrical engineering knowledge and experience.

Incorrect installation endangers your life and that of the user of the electrical system.

Incorrect installation can cause serious damage to property, e.g. due to fire.

The minimum necessary expert knowledge and requirements for the installation are as follows:

Apply the "five safety rules" (DIN VDE 0105, EN 50110):

1.

Disconnect from power;

2.

Secure against being re-connected;

3.

Ensure there is no voltage;

4.

Connect to earth;

5.

Cover or barricade adjacent live parts.

Use suitable personal protective clothing.

Use only suitable tools and measuring devices.

Check the type supply network (TN system, IT system, TT system) to secure the following

power supply conditions (classic connection to ground, protective earthing, necessary

additional measures, etc.).

Pos : 23 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/Mont age/M ont agehinweise - Allgemein @ 19\ mod_1310563670478_15. doc x @ 107743 @ 2 @ 1

6.2

General installation instructions

Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station,

system device).

Do not install the system controller directly next to the bell transformer and other power supplies (to avoid

interference).

Do not install the wires of the system bus together with 230 V wires.

Do not use common cables for the connecting wires of the door openers and wires of the system bus.

Avoid bridges between different cable types.

Use only two wires for the system bus in a four-core or multi-core cable.

When looping, never install the incoming and outgoing bus inside the same cable.

Never install the internal and external bus inside the same cable.

(6)

ABB-Welcome

Mounting / Installation

Pos : 25 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Übersc hrift en (--> Für alle D okument e <--)/2. Ebene/M - O /Mont age @ 18\ mod_1302615960458_15. doc x @ 103424 @ 2 @ 1

6.3

Mounting

Pos : 26 /DinA4 - Anl eitungen Onli ne/I nhalt - Mont age/M ontag e - H utsc hi enen nac h DI N EN 500022 @ 18\ mod_1303218164750_15.doc x @ 103868 @ @ 1

The device 83325/2-5.. must only be installed on mounting rails according to DIN EN 500022.

Pos : 27 /DinA4 - Anl eitungen Onli ne/Ueberschrif ten/ 2. /Ansc hlus s @ 18\ mod_1302617573351_15. doc x @ 103449 @ 2 @ 1

6.4

Connection

Pos : 28 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/83325-2/Ansc hlus s - 83325- 2 @ 18\ mod_1303218164125_15.doc x @ 103844 @ @ 1

Fig. 1:

No.

Function

1

Systemzentrale / Außenbus

System controller / outdoor bus

Centrale système / bus extérieur

Systeemcentrale / buitenbus

Системный контроллер / внешняя шина

Centrala systemu/magistrala zewnętrzna

Systemsentral / utendørs-bus

(7)

ABB-Welcome

Mounting / Installation

| 0073-1-7520

— 7 —

Buitenposten / buitenbus

Внешние переговорные пункты / внешняя шина

Stacje zewnętrzne / magistrala zewnętrzna

Utendørsstasjoner / utendørs-bus

Ytterstationer/ytterbuss

Ulkoasemat / ulkoväylä

Stazioni esterne/bus esterno

Estaciones exteriores / Bus exterior

门口机

/

室外总线

Pos : 29 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Steuermodul e - Onli ne-D okument ation (--> F ür all e D okument e <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\ mod_1268898668093_0.doc x @ 52149 @ @ 1 === Ende der List e f ür T ext mar ke Cont ent ===

(8)

ABB-Welcome

0073

-1

-7520

|

|

10.09.

2015

Notice

=== Ende der List e f ür T ext mar ke Bac kc over ===

We reserve the right to at all times make technical changes as well as changes in the contents of this document without prior

notice.

The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for poss ible

errors or incompleteness in this document.

We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or

extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB.

References

Related documents

o However, where all parties have either perfected their appeals by filing their notices of appeal in due time and period to file such has lapsed for those who did not, then the

— Amount for the higher education sector. — Amount for the government sector. — Amount for private non-profit. — Amount for the public sector, defined as the sum of higher

group of infants born in Tehran (2012-2015). J Qazvin Univ Med Sci.. فﺎﮑﺷ ﺮﯿﻏ يﺎﻫ ﯿﻣرﺪﻨﺳ ﮏ ﯽﻠﻣﺎﻋﺪﻨﭼ ﯽﻣ ﻨﺷﺎﺑ .ﺪ :فﺪﻫ ﯽﺳرﺮﺑ فﺪﻫ ﺎﺑ ﻪﻌﻟﺎﻄﻣ ﻦﯾا ﻮﻧ زا ﯽﻫوﺮﮔ رد

• Phased evolution approach build on the Finnish Smart Grid 1.0 • Phased evolution approach build on the Finnish Smart Grid 1.0.. Research highlights

Though students and families are borrowing more to cope with the ever-growing cost of college, the loans that they are taking out may actually be a cause, as well as a result, of

The aim of this thesis was to investigate times to loss of consciousness and the relationships between behavioural indicators, physical signs, reflexes and brain activity,

Wanting to help show support and respect for Jeanne, I asked if I could add a composed fanfare to the activities.. And so with the help of Mark, Pat and Michael Anderson, and the

Each project management competence element is composed of both knowledge and experience and shall be used for assessment at each IPMA