Design Comparison Summary

N/A
N/A
Protected

Academic year: 2022

Share "Design Comparison Summary"

Copied!
8
0
0

Loading.... (view fulltext now)

Full text

(1)

Innstruct/Orig. Reduced

336.3 ft

3

12.5 yd

3

231.9 ft

3

8.6 yd

3

445.0 ft

3

16.5 yd

3

306.9 ft

3

11.4 yd

3

312.1 ft

3

11.6 yd

3

215.3 ft

3

8.0 yd

3

1093.4 ft

3

40.5 yd

3

754.1 ft

3

27.9 yd

3

10805.1 in

3

3063.9 lbs 2989.9 in

3

847.8 lbs 28% 72%

6115.1 in

3

1734.0 lbs 889.6 in

3

252.3 lbs 15% 85%

8233.3 in

3

2334.7 lbs 2553.6 in

3

724.1 lbs 31% 69%

25153.5 in

3

7132.6 lbs 6433.1 in

3

1824.2 lbs 26% 74%

Design Comparison Summary

Panel B (ft

3

/yd

3

) Panel N (ft

3

/yd

3

) Panel G (ft

3

/yd

3

) Total (ft

3

/yd

3

)

Concrete

Description Original Design Innstruct Design

The comparison of concrete and mild reinforcing steel is completed for general comparison purposes only. Potential reductions in concrete and reinforcement will vary depending on the efficiency of the concrete tilt-up panel design, vertical and out of plane loading, height of panel, and architectural treatment. The comparisons presented herein do not include a slight increase in concrete required where EPS is removed at embed plates and for concrete edges at the sides and openings in the panels.

Additional Reinf.

Panel B (in

3

/lbs) Panel N (in

3

/lbs) Panel G (in

3

/lbs) Total (in

3

)

69% 31%

(2)

Forsgren Associates Inc.

435-227-0333

Innovative Structural Solutions Tilt-up Panel Design Comparison

11/22/2019

Length Height Thickness

7-1/4" 20.00 32.83 0.604 336.28 12.45 3" Ext. 139.15 5.15

Total 336.28 12.45 2" Int. 92.77 3.44

Σ = 231.92 8.59

Area Width (in) Layer Total Bars Bar Size Diameter Bar Area (in2) Length (ft) Volume (in3) #3 at 8" Ties Quantity Length (in) Volume (in3)

L. Chord 36.00 Double 18 #5 0.625 0.310 32.41 2170.40 No 0 0.00 0.00

Openings 120.00 Single 10 #5 0.625 0.310 21.75 808.98 No 0 0.00 0.00

Center 48.00 Double 24 #5 0.625 0.310 32.41 2893.86 No 0 0.00 0.00

R. Chord 36.00 Double 18 #5 0.625 0.310 32.41 2170.40 No 0 0.00 0.00

Σ = 20.00 ft Σ = 8043.63 Σ = 0.00

Area Height (in) Layer Total Bars Bar Size Diameter Bar Area (in2) Length (ft) Volume (in3) NA Quantity Length (in) Volume (in3)

Full Width 273.96 Single 21 #5 0.625 0.310 19.67 1536.36 No 0 0.00 0.00

Openings 120.00 Single 10 #5 0.625 0.310 9.33 347.20 No 0 0.00 0.00

Bond Beams 0.00 Double 12 #5 0.625 0.310 19.67 877.92 No 0 0.00 0.00

Σ = 32.83 ft Σ = 2761.48 Σ = 0.00

8043.63 in3 2761.48 in3 10805.11 in3 3063.9 lbf Total Panel Reinforcement Volume (in3) Σ =

+ Total Horizontal Reinforcement Volume (in3) = Total Vertial Reinforcement Volume (in3) =

Total Panel Reinforcement Weight (lbf) = Total Panel Concrete Volume (ft3 or yd3) Σ =

Panel B - Original Reinforcement Summary

Horizontal Panel Reinforcement

Longitudinal Reinforcement

Longitudinal Reinforcement Transverse Reinforcement

Transverse Reinforcement Description & Dimensions

Vertical Panel Reinforcement

Description & Dimensions

Volume (yd3) Panel B - Innstruct Concrete Design Summary Panel B - Original Concrete Design Summary

Description Member Geometry (ft) Opening (ft2)

Volume (ft3) Volume (yd3) Description Member

Concrete

Total Openings 100.00

Concrete

Volume (ft3)

(3)

Length Height Thickness

7-1/4" 20.00 36.83 0.604 445.03 16.48 3" Ext. 184.15 6.82

Total 445.03 16.48 2" Int. 122.77 4.55

Σ = 306.92 11.37

Area Width (in) Layer Total Bars Bar Size Diameter Bar Area (in2) Length (ft) Volume (in3) #3 at 8" Ties Quantity Length (in) Volume (in3)

L. Chord 4.00 Double 2 #5 0.625 0.310 36.41 270.92 No 0 0.00 0.00

Center 232.00 Single 19 #5 0.625 0.310 36.41 2573.69 No 0 0.00 0.00

R. Chord 4.00 Double 2 #5 0.625 0.310 36.41 270.92 No 0 0.00 0.00

Σ = 20.00 ft Σ = 3115.52 Σ = 0.00

Area Height (in) Layer Total Bars Bar Size Diameter Bar Area (in2) Length (ft) Volume (in3) NA Quantity Length (in) Volume (in3)

Full Width 437.96 Single 37 #5 0.625 0.310 19.67 2706.92 No 0 0.00 0.00

Bond Beams 4.00 Double 4 #5 0.625 0.310 19.67 292.64 No 0 0.00 0.00

Σ = 36.83 ft Σ = 2999.56 Σ = 0.00

3115.52 in3 2999.56 in3 6115.08 in3 1734.0 lbf

Panel N - Original Concrete Design Summary Panel N - Innstruct Concrete Design Summary Description Member Geometry (ft) Opening (ft2)

Volume (ft3) Volume (yd3) Description Member Volume (ft3) Volume (yd3) Total Openings

Concrete 0.00

Concrete Total Panel Concrete Volume (ft3 or yd3) Σ =

Panel N - Original Reinforcement Summary

Description & Dimensions Longitudinal Reinforcement Transverse Reinforcement

Description & Dimensions Longitudinal Reinforcement Transverse Reinforcement

Vertical Panel Reinforcement

Total Vertial Reinforcement Volume (in3) = + Total Horizontal Reinforcement Volume (in3) = Total Panel Reinforcement Volume (in3) Σ = Total Panel Reinforcement Weight (lbf) = Horizontal

Panel Reinforcement

(4)

Forsgren Associates Inc.

435-227-0333

Innovative Structural Solutions Tilt-up Panel Design Comparison

11/22/2019

Length Height Thickness

7-1/4" 20.00 34.83 0.604 312.11 11.56 3" Ext. 129.15 4.78

Total

312.11 11.56

2" Int. 86.10 3.19

Σ = 215.25 7.97

Area Width (in) Layer Total Bars Bar Size Diameter Bar Area (in2) Length (ft) Volume (in3) #3 at 8" Ties Quantity Length (in) Volume (in3)

L. Chord 60.00 Double 22 #5 0.625 0.310 34.41 2816.39 No

0 0.00

0.00

Openings 144.00 Single 13 #5 0.625 0.310 23.75 1148.39 No

0 0.00

0.00

R. Chord 36.00 Double 14 #5 0.625 0.310 34.41 1792.25 No

0 0.00

0.00

Σ = 20.00 ft Σ =

5757.02

Σ =

0.00

Area Height (in) Layer Total Bars Bar Size Diameter Bar Area (in2) Length (ft) Volume (in3) NA Quantity Length (in) Volume (in3)

Full Width 297.96 Single 16 #5 0.625 0.310 19.67 1170.56 No

0 0.00

0.00

Openings 120.00 Single 15 #5 0.625 0.310 7.67 427.80 No

0 0.00

0.00

Bond Beams 0.00 Double 12 #5 0.625 0.310 19.67 877.92 No

0 0.00

0.00

Σ = 34.83 ft Σ =

2476.28

Σ =

0.00

5757.02 in

3

2476.28 in

3

8233.30 in

3

2334.7 lbf

Panel G - Original Concrete Design Summary Panel G - Innstruct Concrete Design Summary Description Member Geometry (ft) Opening (ft

2

)

Volume (ft3) Volume (yd3)

Description Member

Description & Dimensions Longitudinal Reinforcement Transverse Reinforcement

Volume (ft3) Volume (yd3)

Total Openings

Concrete

180.00

Concrete

Total Panel Concrete Volume (ft3 or yd3) Σ =

Vertical Panel Reinforcement

Panel G - Original Reinforcement Summary

Description & Dimensions Longitudinal Reinforcement Transverse Reinforcement

Horizontal Panel Reinforcement

Total Vertial Reinforcement Volume (in

3

) =

+ Total Horizontal Reinforcement Volume (in

3

) =

Total Panel Reinforcement Volume (in

3

) Σ =

Total Panel Reinforcement Weight (lbf) =

(5)

2 3 4 5 6 7 8 9 14 15 16 17 18 19 20

Description Total Bars Bar Size Diameter Bar Area (in

2

) Length (ft) Volume (in

3

)

Left 4 #4 0.500 0.200 32.50 311.97 2989.90 in

3

Center 6 #5 0.625 0.310 32.50 725.33 847.8 lbf

Right 4 #4 0.500 0.200 32.50 311.97

Horiz. Bars 12 #4 0.500 0.200 19.67 566.40

Vert. Bars 8 #4 0.500 0.200 36.50 700.74 889.57 in

3

Horiz. Bars 4 #4 0.500 0.200 19.67 188.83 252.3 lbf

Left 14 #4 0.500 0.200 34.50 1159.20

Right 10 #4 0.500 0.200 34.50 828.00 2553.60 in

3

Horiz. Bars 12 #4 0.500 0.200 19.67 566.40 724.1 lbf

G B

Panel B, N, and G - Innstruct Panel Addtional Reinforcement Summary

N

(6)

3'-5 3/4" (3) #5 EACH FACE

#4 EACH FACE

#4 EACH FACE

PANEL TYPE B B

32'-10" #5 AT 12"

(2) #5 (2) #5

(2) #5 (2) #5

#5 AT 12"

20'-0"

ORIGINAL PANEL DESIGN

#5 AT 12"

(2) #5 AT 4"

(2) #5 AT 4"

(2) #5 AT 4"

INNSTRUCT PANEL DESIGN

#4 EACH FACE

#4 EACH

FACE

(7)

PANEL TYPE N N

#4 EACH FACE

#4 EACH FACE

36'-10" #5 AT 12"

(2) #5 (2) #5

(2) #5 20'-0"

20'-0"

CONCRETE TILT-UP PANEL INNSTRUCT PANEL DESIGN

#4 EACH

FACE

(8)

PANEL TYPE G G

2'-3/4"

(5) #4 EACH FACE

34'-10"

#5 AT 12"

#5 AT 12"

ORIGINAL PANEL DESIGN

#5 AT 4"

EACH

FACE #5 EACH FACE

INNSTRUCT PANEL DESIGN 3'-5 3/4"

(5) #4 EACH FACE

#5 AT 4"

EACH FACE

#5 EACH FACE

#5 EACH FACE

#5 EACH FACE

#5 EACH FACE

#5 EACH FACE

(4) #4 FULL HEIGHT FOR PANEL LEG PANEL

LEG

#4 EA FACE ABOVE AND BELOW OPENING

#4 EA FACE ABOVE AND BELOW OPENING

#4 EA FACE

#4 EA FACE

References

Related documents

Even though, both the sites were favoured by almost same meteorological conditions, a difference of 2.01 ppb was observed in the mean of daily average surface ozone

Subject Matter Expert – Oracle OAAM and IDM Setup Design and Implementation (Each Master Contractor can only submit three candidate for the RFR).. Anticipated start date June

Equipment Vendor: Valley DCF Waterbury 395 West

For this section, students are asked to submit digital images of 8 three- dimensional works, with 2 views of each work, for a total of 16 images.. All images should be

As noted in the Literature Review, above, scholarship on the determinants of foreign direct investment (FDI) variously argue the influence of GDP growth, the openness of a

This study uses data from 19 Indonesian toll roads over 2008–2015 to calculate the effects of Indonesia’s historic recent fuel subsidy reforms on motor vehicle travel.. The timing

Heterogeneous hardware and software resources are unified for efficient use in cloud environments. Heterogeneity may cause flaws as security settings may differ for different kinds

parameters that we aim to identify are the aggregate effect of the subsidy on the treatment group, where treatment is either being in the pilot region or being eligible to subsidized