• No results found

Absorption titration

Binding of Heavy Metals with C-Phycocyanin: A Comparison between Equilibrium Dialysis, Fluorescence and Absorption Titration

Binding of Heavy Metals with C-Phycocyanin: A Comparison between Equilibrium Dialysis, Fluorescence and Absorption Titration

... Abstract: The energetic of interaction of metal ions with C-Phycocyanin (C-PC) Spirulina platensis were investigated using optical and thermodynamic methods. Comparison of the binding constants of heavy metals with C-PC ...

5

DNA interaction and biological activities of Copper(II) complexes of alkylamidio O methylurea

DNA interaction and biological activities of Copper(II) complexes of alkylamidio O methylurea

... Two of copper(II)complexes,bis(1-methylamidino-O-methylurea)copper(II)chloride(1) and bis(1- ethylamidino-O-methyl urea)copper(II)chloride(2)were prepared. The complexes were characterized by analytical analysis, IR and ...

8

New mixed ligand complexes of ruthenium(ii) that incorporate a modified phenanthroline ligand: Synthesis, spectral characterization and DNA binding

New mixed ligand complexes of ruthenium(ii) that incorporate a modified phenanthroline ligand: Synthesis, spectral characterization and DNA binding

... 2.3a Absorption titration: Absorption titration experiments (5 mM Tris, 50 mM NaCl, pH 7⋅0) were performed by using a fixed metal complex concentration to which increments of the stock DNA ...

13

Binding studies of some novel macroacyclic transition metal complexes towards CT DNA via multispectroscopic techniques

Binding studies of some novel macroacyclic transition metal complexes towards CT DNA via multispectroscopic techniques

... DNA, viscosity of DNA solutions containing varying amount of added complexes were measured. Classical intercalative mode causes a significant increase in viscosity of DNA solution due to separation of base pairs at ...

18

Synthesis, Characterization, DNA binding and spectral properties of complex [Ru(py)4(dppz)]2+

Synthesis, Characterization, DNA binding and spectral properties of complex [Ru(py)4(dppz)]2+

... Electronic absorption measurements: The application of electronic absorption spectroscopy in DNA-binding studies is one of the most useful ...techniques.[39] Absorption titration experiment ...

10

MIXED LIGAND COMPLEXES OF CU(II),/NI(II)/ ZN(II) IONS CONTAINING 1,2-DI(2-THIENYL)-1,2-ETHANEDIONE,HYDRAZINE HYDRATE AND METHYL SALICYLALDEHYDE: SYNTHESIS, CHARACTERIZATION AND DNA BINDING ACTIVITY.Thiruchendil Muthu K, Iyyam Pillai S, and P. Venkatesh*DO

MIXED LIGAND COMPLEXES OF CU(II),/NI(II)/ ZN(II) IONS CONTAINING 1,2-DI(2-THIENYL)-1,2-ETHANEDIONE,HYDRAZINE HYDRATE AND METHYL SALICYLALDEHYDE: SYNTHESIS, CHARACTERIZATION AND DNA BINDING ACTIVITY.Thiruchendil Muthu K, Iyyam Pillai S, and P. Venkatesh*DOWNLOAD/VIEW

... Electronic absorption spectroscopy has been widely employed to determine the binding ability of metal complexes with DNA ...complexes. Absorption titration measurements were done by varying the ...

16

ESTIMATION OF POTENTIAL AND EFFECTIVE BR?NSTED ACID SITE CONCENTRATIONS IN ACIDIC MORDENITES BY CONDUCTOMETRIC TITRATION METHOD

ESTIMATION OF POTENTIAL AND EFFECTIVE BR?NSTED ACID SITE CONCENTRATIONS IN ACIDIC MORDENITES BY CONDUCTOMETRIC TITRATION METHOD

... potentiometric titration in both aqueous and non-aqueous solvents have been used for characterizing zeolites ...Aqueous titration techniques using Hammett indicators have a large number of limitations, ...

7

A Multiparameter Colloidal Titrations for the Determination of Cationic Polyelectrolytes

A Multiparameter Colloidal Titrations for the Determination of Cationic Polyelectrolytes

... direct titration of anionic PEs, there are few suitable indicators that show a distinct color change end point; moreover another disadvantage is that the absorption spectrum of the indicator is pH ...

12

STABILITY CONSTANTS OF MIXED LIGAND COMPLEXES OF TRANSITION METAL (II) IONS WITH 4-BROMO-2-{(E)-[(2-METHYL-5-NITROPHENYL) IMINO]METHYL}PHENOL AND 1-{(E)-[(4-METHOXY-2-METHYLPHENYL) IMINO]METHYL}NAPHTHALEN-2-OL.

STABILITY CONSTANTS OF MIXED LIGAND COMPLEXES OF TRANSITION METAL (II) IONS WITH 4-BROMO-2-{(E)-[(2-METHYL-5-NITROPHENYL) IMINO]METHYL}PHENOL AND 1-{(E)-[(4-METHOXY-2-METHYLPHENYL) IMINO]METHYL}NAPHTHALEN-2-OL.

... the titration curves indicate that the ternary complexes formation has taken place in the solution on the following grounds: (I) the horizontal distance was measured between ternary titration curves of ...

6

Karl Fischer Titration

Karl Fischer Titration

... The basis of reliable results is set long before the daily routine: evaluation and selection of a suitable titration system as well as proper installation and training on correct operation. Appropriate maintenance ...

16

The Precise and Accurate Determination of Lithium Hydroxide Solutions  EUR 3656

The Precise and Accurate Determination of Lithium Hydroxide Solutions EUR 3656

... CONCLUSION A comparison of the results of four methods acid-base titration with hydrochloric acid, acid-base titration with benzoic acid, weighing as sulphate and weighing as carbonate -[r] ...

32

Activation of a beta-galactosidase recombinant provirus: application to titration of human immunodeficiency virus (HIV) and HIV-infected cells.

Activation of a beta-galactosidase recombinant provirus: application to titration of human immunodeficiency virus (HIV) and HIV-infected cells.

... They are as follows: i direct titration of viral particles, ii direct titration of cells producing the virus and/or expressing a provirus, and iii indirect detection of the virus followi[r] ...

9

An automatic recording titrator

An automatic recording titrator

... An automatic recording titrator is described which is applicable to all types of potentiometric titrations. Particular attention has been paid to the maintenance of accurate potential recording of the entire ...

56

2014 FRQ-scoring guidelines.pdf

2014 FRQ-scoring guidelines.pdf

... 4.89, the pH at the equivalence point in the titration of butanoic acid should be close enough to the pH in the titration of propanoic acid to make the original indicator appropria[r] ...

18

“HIBISCUS SABDARIFFA ANTHOCYANIDINS: A POTENTIAL TWO-COLOUR
                                    END-POINT INDICATOR IN ACID-BASE AND COMPLEXOMETRIC TITRATIONS” by Okonkwo, Tochukwu  Josiah Nnaemeka, Nigeria.

“HIBISCUS SABDARIFFA ANTHOCYANIDINS: A POTENTIAL TWO-COLOUR END-POINT INDICATOR IN ACID-BASE AND COMPLEXOMETRIC TITRATIONS” by Okonkwo, Tochukwu  Josiah Nnaemeka, Nigeria.

... light absorption spectra of the methanol extract at varying pH values (1-14) were also obtained and ...Prominent absorption in the 500 - 550 nm wavelength region of the uv/visible spectrum of the methanol ...

6

Titrations

Titrations

... When choosing an indicator for a titration, it is important to match its pH range (the pH values where it changes colour) to the endpoint of the titration. Why is litmus not a[r] ...

31

Efficient coating of the solid phase with rotavirus antigens for enzyme linked immunosorbent assay of immunoglobulin A antibody in feces

Efficient coating of the solid phase with rotavirus antigens for enzyme linked immunosorbent assay of immunoglobulin A antibody in feces

... Moreover, when the guinea pig serum was used for coating of wells, the titration curve was not as sensitive as that with the rabbit antiserum; probably, the titration curves in method B [r] ...

5

The Catalytic Site of Lysozyme

The Catalytic Site of Lysozyme

... The titration of glutamic acid residue 35 in the derivative is perturbed, though, and from the shape of the difference titration curve the ionization behavior of Asp 52 a[r] ...

219

Apparatus for rapid electrometric titration

Apparatus for rapid electrometric titration

... Smaller electrode vessels are then used, and the standard half-cell is either a calomel half-cell or a quinhydrone half-cell containing a buffer solution of accurately known pH.. is dete[r] ...

10

Tm3+-PVC Membrane Electrochemical Sensor Based on N-[(E)-1-(2-thienyl)methylidene]-N-{4-[(4-{[(Z)-1-(2-thienyl)methylidene]amino}phenyl)sulfonyl]phenyl}amine

Tm3+-PVC Membrane Electrochemical Sensor Based on N-[(E)-1-(2-thienyl)methylidene]-N-{4-[(4-{[(Z)-1-(2-thienyl)methylidene]amino}phenyl)sulfonyl]phenyl}amine

... to 1.0×10 −2 mol L -1 with the detection limit of 6.9×10 −7 mol L -1 at a pH range of 3.1–8.9. The electrode shows a fast response time (~5 s). This sensor shows very good selectivity and sensitivity towards thulium ion ...

10

Show all 6579 documents...

Related subjects