• No results found

Cardiac implantable electronic device

Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement

Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement

... Figure 1. Histological slide containing longitudinal sections of cephalic vein segments: the segment upstream of the valve (A) and at the valve base (B). Masson’s trichrome stain visualises alternating collagen fibres ...

7

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

... Background: Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional ...

6

Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

... of cardiac implantable electronic device (CIED) implantation have increased in the last ...the device, there are multiple sources of potential expense; prolonged courses of antibiotics ...

13

Radiotherapy-induced cardiac implantable electronic device disorders in cancer patients.

Radiotherapy-induced cardiac implantable electronic device disorders in cancer patients.

... the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or ...shorter device-age at the time of radiotherapy compared to those ...

16

Imaging topography and morphometry of persistent left superior caval vein and its variations, detected on cardiac implantable electronic device implantation

Imaging topography and morphometry of persistent left superior caval vein and its variations, detected on cardiac implantable electronic device implantation

... old; cardiac implantable electronic device with cardiac leads introduced through the persistent left superior caval vein into the right atrium (RA) via the coronary sinus (CS); ...

8

Axillary vein spasm during cardiac implantable electronic device implantation

Axillary vein spasm during cardiac implantable electronic device implantation

... Background: The technique of axillary vein (AV) or subclavian vein (SV) puncture has become an important alternative to cephalic vein (CV) cutdown as an appro- ach allowing cardiac lead introduction into the ...

7

Morphometric parameters of cardiac implantable electronic device (CIED) pocket walls observed on device replacement

Morphometric parameters of cardiac implantable electronic device (CIED) pocket walls observed on device replacement

... of cardiac implantable electronic device (CIED) capsules ...18-year-old device pocket with evidence of capsule wall calcification, during a second-time cardiac implantable ...

7

Review of cardiac implantable electronic device related infection

<div>Review of cardiac implantable electronic device related infection</div>

... Abstract: Cardiac implantable electronic devices (CIEDs) are being used more and more often ...Keywords: cardiac implantable electronic device, infection, pacemaker, ...

10

A rare vascular anomaly in the form of double left brachiocephalic vein detected incidentally during cardiac implantable electronic device (CIED) placement

A rare vascular anomaly in the form of double left brachiocephalic vein detected incidentally during cardiac implantable electronic device (CIED) placement

... The growing number of transvenous cardiac implantable electronic device (CIED) implantation procedures helps detect rare vascular anomalies. Genetic disturbances in vascular development can ...

5

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

... Segmental stenoses, either isolated or multiple, of the vascular lumen were found in 3 cases, with no change observed following lidocaine administration directly into the CV segment visualised in the device ...

7

Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

... last device related ...epicardial device implantations [19, 23, 28, 29, ...the device or pocket at the time of insertion or during surgical manipu- ...

10

Chest radiographs of cardiac devices (Part 1): Cardiovascular implantable electronic devices, cardiac valve prostheses and Amplatzer occluder devices

Chest radiographs of cardiac devices (Part 1): Cardiovascular implantable electronic devices, cardiac valve prostheses and Amplatzer occluder devices

... medical device that regulates the heart rate by electrical impulses delivered through electrodes to the heart ...this device is to maintain an adequate Several new innovative cardiac devices have ...

13

Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis

Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis

... the implantable device system; infection is least frequent in pacemaker patients, more frequent in patients with an ICD and most frequent in biventricular resynchronization therapy patients (with CRT-P or ...

8

Impact of transvenous cardiac implantable electronic devices in chronic hemodialysis patients: a single-center, observational comparative study

Impact of transvenous cardiac implantable electronic devices in chronic hemodialysis patients: a single-center, observational comparative study

... of device-related infections, including endo- carditis, in chronic hemodialysis patients with transve- nous CIEDs, has been reported to be higher than that among members of the general population with CIEDs ...

8

Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center

Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center

... of cardiac pacemakers and antiarrhythmia devices); American Association for Thoracic Surgery; Society of Thoracic ...for device-based therapy of cardiac rhythm abnormalities: a report of the American ...

9

Original Article Prospective randomized study of axillary venous access with or without fluoroscopy-guided in cardiovascular implantable electronic device implantation

Original Article Prospective randomized study of axillary venous access with or without fluoroscopy-guided in cardiovascular implantable electronic device implantation

... (PM), implantable car- dioverter defibrillators (ICD), and cardiac resyn- chronization therapy pacemakers/defibrillators (CRT-P/CRT-D) were prospectively evaluated using axillary vein puncture as the ...

6

Critical appraisal of cardiac implantable electronic devices: complications and management

Critical appraisal of cardiac implantable electronic devices: complications and management

... the device is a special counter, which measures the interval in milliseconds between the native beats: if this interval exceeds the one programmed as “lower rate” the device will deliver an electrical pulse ...

11

Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection

Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection

... ABSTRACT Device infection remains a significant challenge as clinical indications for cardiovascular implantable electronic device (CIED) therapy continue to expand beyond the prevention and ...

9

New guidelines for prevention and management of implantable cardiac electronic device-related infection

New guidelines for prevention and management of implantable cardiac electronic device-related infection

... in cardiac catheter laboratory or radiology suites where ICED implantation procedures are ...to device insertion, even though high-level evidence to support this recommendation is ...

5

Guidelines for the diagnosis, management and prevention of implantable cardiac electronic device infection

Guidelines for the diagnosis, management and prevention of implantable cardiac electronic device infection

... Implantable cardiac electronic devices (ICED) comprise permanent pacemakers (PPM), implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy ...

12

Show all 10000 documents...

Related subjects