• No results found

Dynamic Condylar Screw Plate

A comparative study of functional outcome of Closed Subtrochanteric Fractures managed by Dynamic Condylar Screw and Reconstruction Nail

A comparative study of functional outcome of Closed Subtrochanteric Fractures managed by Dynamic Condylar Screw and Reconstruction Nail

... operating table. Full manipulation of leg facilitates the reduction and fixation of spiral and oblique fractures and their butterfly fragments. However placement of the 95 degree blade plate is a technically ...

88

“Revision of subtrochanteric femoral nonunions after intramedullary nailing with dynamic condylar screw”

“Revision of subtrochanteric femoral nonunions after intramedullary nailing with dynamic condylar screw”

... dynamization, plate revision of the subtrochanteric femoral nonunions has also been ...blade plate fail- ure was ...the plate for partial removal of the implant and one superficial wound infection ...

12

Study of Internal Fixation of Subtrochantric Fracture of Femur with Dynamic Hip Screw, Dynamic Condylar Screw and Proximal Femoral Nail

Study of Internal Fixation of Subtrochantric Fracture of Femur with Dynamic Hip Screw, Dynamic Condylar Screw and Proximal Femoral Nail

... 95°dynamic condylar screw is a two-piece device with the same basic design as the 95°condylar blade plate but with the blade replaced by a large-diameter cannulated lag screw ...

23

Comparative analysis of functional outcome of distal femur fractures treated with Locking Compression Plate fixation and Dynamic Condylar Screw fixation

Comparative analysis of functional outcome of distal femur fractures treated with Locking Compression Plate fixation and Dynamic Condylar Screw fixation

... Our study is short term prospective and retrospective study conducted in Institute of orthopedics and traumatology, Madras medical college, Rajiv Gandhi Govt. General Hospital. Chennai. Tamil Nadu. Patients admitted with ...

132

Original Research Article Outcome of Subtrochanteric Fractures of Femur Managed by Internal Fixation using long Proximal Femoral Nail: A Prospective Study

Original Research Article Outcome of Subtrochanteric Fractures of Femur Managed by Internal Fixation using long Proximal Femoral Nail: A Prospective Study

... Subtrochanteric fractures of the proximal femur continue to be a challenge to an Orthopaedic surgeon. The specific anatomy, biomechanical stresses and forces acting at the region, make the management difficult. 1 Present ...

7

Comparison of supraintercondylar and supracondylar femur fractures treated with condylar buttress plates

Comparison of supraintercondylar and supracondylar femur fractures treated with condylar buttress plates

... fixed-angle condylar plate ...with dynamic condylar screwing or retrograde intramedullary supracondylar nailing ...the dynamic condylar screwing and retrograde nailing groups, ...

8

Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures

Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures

... All nails, plates and screws were removed from individual femurs prior to any cuts being made. A femur would then be clamped within a custom made bone cutting jig and cuts made using either a Y fracture guide or an ...

7

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

... plates, dynamic condylar screw or distal femur supracondylar nailing for internal fixation depends on the type of fracture and the pre operative planning and in- tra operate decision of the ...

6

Outcome analysis of subtrochanteric fractures fixed with dynamic condylar screw, dynamic hip screw and reconstruction nail

Outcome analysis of subtrochanteric fractures fixed with dynamic condylar screw, dynamic hip screw and reconstruction nail

... Roy Sanders and Piettro from Switzerland, stated that since it required alignment only in two planes they were hopeful that the DCS (25,26,27) would prove easier to insert and mechanically as effective as 95° ...

90

Fixation of Subtrochanteric Fracture of the Femur: Our Experience

Click here to download PDF version of the article !

... Bending forces cause the medial cortex to be loaded in compres- sion and the lateral cortex to be loaded in tension. The compression forces are much higher than the tensile forces and they are therefore mandatory in ...

5

Locking compression plate distal ulna hook plate fixation versus intramedullary screw fixation for displaced avulsion fifth Metatarsal Base fractures: a comparative retrospective cohort study

Locking compression plate distal ulna hook plate fixation versus intramedullary screw fixation for displaced avulsion fifth Metatarsal Base fractures: a comparative retrospective cohort study

... hook plate for a novel ap- proach. There were only 4 studies studied the plate in the treatment of FMBFs [13, ...mini-hook plate [13, 15, ...Low-Profile Plate fixation of a jones fracture ...

6

Infant and Young Child Feeding Practices among the Mothers in Urban Slums of Dibrugarh Town: A Cross Sectional Study

Infant and Young Child Feeding Practices among the Mothers in Urban Slums of Dibrugarh Town: A Cross Sectional Study

... Varus deformity >5° was found in 1 patient and that was due to loss of construct stability, leading to decrease in barrel plate angle due to early unprotected full weight bearing before radiological union. ...

5

Condyle dislocation following mandibular reconstruction using a fibula free flap: complication cases

Condyle dislocation following mandibular reconstruction using a fibula free flap: complication cases

... 2.3-mm plate, and a single 2.7-mm plate were used at the fibular resection sites in three different groups, re- ...cases, condylar displacement was observed in both fixation methods that two mini- ...

10

Slotting/Milling Attachment to Enhance Features of Lathe

Slotting/Milling Attachment to Enhance Features of Lathe

... vertically in each jaw symmetrically and in the same vertical line and the fourth hole is made at the exterior top portion of each plate. The moving jaw can be brought to a position, which grips the work piece ...

6

Lean Manufacturing of Pressure Valve Plate

Lean Manufacturing of Pressure Valve Plate

... Valve Plate is considered as complex process that demands the knowledge of different areas, such as geometry, tolerances, dimensions, manufacturing procedures and manufacturing ...

11

Kinesiophobia in Patients After Dynamic Hip Screw Placement with Open Procedure

Kinesiophobia in Patients After Dynamic Hip Screw Placement with Open Procedure

... Hip Screw (DHS) is used in surgical procedures using a plate with a screw to hold a fracture of hip ...procedure dynamic hip screw ...

35

The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty

The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty

... metal plate laterally on the femur, proximal fixation using cables, and distal fixation with bicortical screws ...with plate fixation or have compared constructs using plate fixation and allograft ...

8

Histopathological features of condylar hyperplasia and condylar Osteochondroma: a comparison study

Histopathological features of condylar hyperplasia and condylar Osteochondroma: a comparison study

... growth plate, arising from endochondral ...both condylar osteochondroma and condylar hyperplasia represent features of endo- chondral ...growth plate, and possibly in osteochondromas [20] [36, ...

12

Rotational landmarks of the distal femur in Indian population: A MRI-based study

Rotational landmarks of the distal femur in Indian population: A MRI-based study

... Measured resection is the most popular technique in India, and the conventional jigs have 3° of inbuilt external rotation. Failure to make the difference between the CTA and PCA would lead to component position in ...

6

Comparison of three different fixation constructs for radial neck fractures: a biomechanical study

Comparison of three different fixation constructs for radial neck fractures: a biomechanical study

... head plate and screws (Stryker, Mahwah, NJ, USA) or two different ori- entations (crossed and parallel) of screw fixation (AO, Davos, ...The plate group included a plate construct involving ...

7

Show all 10000 documents...