• No results found

Esophageal pH monitoring

Clinical utility and tolerability of JSPH-1 wireless esophageal pH monitoring system

Clinical utility and tolerability of JSPH-1 wireless esophageal pH monitoring system

... to esophageal mucosa ...if pH capsule was detached, the patients would exit the later ...Shan pH monitoring working station. All pH data was provided along with pH tracings of ...

7

Laparoscopic fundoplication for a case of esophageal hiatal hernia after gastroschisis repair

Laparoscopic fundoplication for a case of esophageal hiatal hernia after gastroschisis repair

... 24-h esophageal pH monitoring and/or upper gastrointestinal series, 7 out of 15 patients with congenital abdominal wall defects developed GER, including 5 cases with hiatal hernia, after surgery ...

5

The child with chronic cough: when does double channel pH monitoring rule out gastroesophageal reflux

The child with chronic cough: when does double channel pH monitoring rule out gastroesophageal reflux

... Background: gastroesophageal reflux (GER) plays a major role in the pathogenesis of pediatric chronic airway disease. Esophageal pH-monitoring (epHM) is the diagnostic gold standard for acid GER. To ...

6

Influence of Xanthines on Gastroesophageal Reflux in Infants at Risk for Sudden Infant Death Syndrome

Influence of Xanthines on Gastroesophageal Reflux in Infants at Risk for Sudden Infant Death Syndrome

... The finding of normal results for esophageal pH monitoring in all infants before and 3 to 4 weeks after the administration of the xanthines was stopped indicates that gastrointestinal re[r] ...

6

Gastroesophageal Reflux Associated With Nemaline Myopathy of Infancy

Gastroesophageal Reflux Associated With Nemaline Myopathy of Infancy

... 2), and prolonged esophageal pH monitoring 2 months after surgery indicated no significant gastroesophageal reflux (Table)1. Patient 3.[r] ...

7

Reproducibility of 24-Hour Intraesophageal pH Monitoring

Reproducibility of 24-Hour Intraesophageal pH Monitoring

... method. The reason for the high false-negative rate is that feedings are a potent stimulus for gastroesophageal reflux episodes. Wake- fulness is also a potent stimulus for gastroesophageal reflux epi- sodes. Depending ...

5

Discussing the influence of electrode location in the result of esophageal prolonged pH monitoring

Discussing the influence of electrode location in the result of esophageal prolonged pH monitoring

... prolonged esophageal pH monitoring could be increased with lower location of the pH-metric ...that pH monitoring is most likely to be normal using conventional and the most ...

5

Reproducibility of 24-Hour Intraesophageal pH Monitoring in Pediatric Patients

Reproducibility of 24-Hour Intraesophageal pH Monitoring in Pediatric Patients

... 24-hour pH monitoring is only 69% (r 5 ...the pH was abnormal was ...with pH <4 (r 5 ...intra- esophageal pH monitoring in the pediatric population is ...–263; ...

6

PubMedCentral-PMC4948126.pdf

PubMedCentral-PMC4948126.pdf

... 24-hour pH monitoring of 87% in 65 patients with IPF, with a prevalence of proximal reflux of ...imal esophageal acid exposure was higher and that the supine acid clearance was slower compared with ...

5

Unsedated peroral wireless pH capsule placement vs. standard pH testing: A randomized study and cost analysis

Unsedated peroral wireless pH capsule placement vs. standard pH testing: A randomized study and cost analysis

... Wireless capsule has been shown to be safe [1] and as sensitive as SC for acid detection [5-7]. Furthermore, the lack of a transnasal catheter permits patient to continue their usual daily activities without impediment. ...

8

Will Esophageal Impedance Replace pH Monitoring?

Will Esophageal Impedance Replace pH Monitoring?

... between esophageal segments, is being used more and more. Multiple esophageal impedance combined with pH monitoring is advocated to become the preferred technique to measure acid and nonacid ...

7

Volume, distribution and acidity of gastric secretion on and off proton pump inhibitor treatment: a randomized double-blind controlled study in patients with gastro-esophageal reflux disease (GERD) and healthy subjects

Volume, distribution and acidity of gastric secretion on and off proton pump inhibitor treatment: a randomized double-blind controlled study in patients with gastro-esophageal reflux disease (GERD) and healthy subjects

... recent pH pull-through and γ-scintigraphy study found no differ- ence in the position or the pH of the acid pocket between partial and complete PPI responders [27], reasons for symptom persistence on PPI ...

11

Fluorescence based fibre optic pH sensor for the pH 10-13 range suitable for corrosion monitoring in concrete structures

Fluorescence based fibre optic pH sensor for the pH 10-13 range suitable for corrosion monitoring in concrete structures

... fibre-optic pH sensors in the literature over the last two to three decades, most of them were constructed to operate, with certain limitations, in the physiological or near neutral pH ...high pH ...

29

Mechanism of gastroesophageal reflux in recumbent asymptomatic human subjects

Mechanism of gastroesophageal reflux in recumbent asymptomatic human subjects

... intraluminal esophageal pH and pressure were obtained on two consecutive nights from 6:00 ...lower esophageal sphincter (LES) pressure via a sleeve device ...(b) esophageal- body motor ...

13

Situs Invertus Totalis in a Patient with Bilateral Papillary Serous Cystadenocarcinoma Ovary: Rare Association with Review of Literature

Situs Invertus Totalis in a Patient with Bilateral Papillary Serous Cystadenocarcinoma Ovary: Rare Association with Review of Literature

... in monitoring of response to systemic chemotherapy in patients with advanced gastric ...in monitoring for recurrence in gastric cancer patients: a prospective clinical ...

6

An integrated silicon sensor with microfluidic chip for monitoring potassium and pH

An integrated silicon sensor with microfluidic chip for monitoring potassium and pH

... Truman et al. (2006) reported the use of silicon-based ISFETs for monitoring transport and chemical properties of liquids in microfluidic systems. Reliable, time-resolved ion, and molecular transport sensing in ...

8

Early Detection Of Labor By Monitoring Antenatal Distinctiveness By PH Device

Early Detection Of Labor By Monitoring Antenatal Distinctiveness By PH Device

... There are many instances known for ―near misses‖. It’s because of no medical assistances during the course of labor which leads to the complications and proportionate mother or fetal mortality or sometimes ...

5

Smart Monitoring Water Quality Detector

Smart Monitoring Water Quality Detector

... quality monitoring system is becoming an importance to implement at the recreational ...quality monitoring system is sufficient yet it is expensive and hard to ...

24

Fluorescence based fibre optic pH sensor for the pH 10-13 range suitable for corrosion monitoring in concrete structures

Fluorescence based fibre optic pH sensor for the pH 10-13 range suitable for corrosion monitoring in concrete structures

... was reduced by 7-8% for the dry state over the time investigated and with the high flux of photons onto the probe. However, under the same conditions, no photobleaching was seen for the similar probe, prepared in exactly ...

31

Ubiquinone modified printed carbon electrodes for cell culture pH monitoring

Ubiquinone modified printed carbon electrodes for cell culture pH monitoring

... of pH is of critical importance in cell culture, with the majority of cell lines favouring pH similar to physiological values of ...physiological pH range, which in turn reduces the potential for ...

18

Show all 10000 documents...

Related subjects