• No results found

failure mode

The Failure Mode and Effect Analysis of a Fuel Handling System at Cernavoda Unit 2

The Failure Mode and Effect Analysis of a Fuel Handling System at Cernavoda Unit 2

... FMEA(Failure Mode & Effect Analysis)[3] study was performed for a fuelling machine and a fuel handling system at Cernavoda unit 2 in ...drawings. Failure of the control and instrumentation ...

7

Risk Analysis in Highway Construction Projects Using Failure Mode & Effect Analysis

Risk Analysis in Highway Construction Projects Using Failure Mode & Effect Analysis

... projects. Failure Mode & Effect Analysis (FMEA) is a structured technique which is recognized as one of the most suitable technique to analyze risk ...

8

To Study the Failure Mode and Effective Analysis of Trailing Arm Weldment

To Study the Failure Mode and Effective Analysis of Trailing Arm Weldment

... axle failure may initiate. Therefore to study the failure mode of a trailing arm weldment, static analysis and fatigue analysis will be done using ANSYS V14 and the results obtained will be discussed ...

10

Problem Solving Of Foot Switches Processes Using Failure Mode And Effects Analysis

Problem Solving Of Foot Switches Processes Using Failure Mode And Effects Analysis

... All budding graduates encompasses from every faculty in Universiti Teknikal Malaysia Melaka, (UTeM) are required to carry out a project in one’s related field of study during the final year. It is compulsory task for all ...

24

Application of failure mode and effects analysis (FMEA) to pretreatment phases in tomotherapy

Application of failure mode and effects analysis (FMEA) to pretreatment phases in tomotherapy

... potential failure modes ...each failure mode: the occurrence rating (O), the severity rating (S), and the detectability rating ...detectable failure mode, ...

13

Failure Mode Effect Analysis in a Frying Pan Manufacturing Industry

Failure Mode Effect Analysis in a Frying Pan Manufacturing Industry

... machine. Failure mode effect analysis (FMEA) is a powerfull tool to estimate the maintenence level required in each ...different failure modes of the machines in the industry and to categorise the ...

7

An Experimental Study of the Failure Mode of ZnO Varistors under Multiple Lightning Stroke

An Experimental Study of the Failure Mode of ZnO Varistors under Multiple Lightning Stroke

... the failure mode of ZnO varistors under multiple lightning stroke, a 5-pulse 8/20 μs nominal lightning current with pulse intervals of 50 ms was applied to the ZnO ...The failure processes of ZnO ...

23

Research on Failure Mode and Effect Analysis of Diesel Engine

Research on Failure Mode and Effect Analysis of Diesel Engine

... As we can earlier discuss the use of diesel engine and due to its high efficiency it is very much required to provide good maintenance and find out the critical part of system so that use engine as long as possible with ...

6

The improvement of Failure Mode, Effects and Criticality Analysis at Grolsch

The improvement of Failure Mode, Effects and Criticality Analysis at Grolsch

... mode ratio (α), conditional probability (β) and operating time (t) (Department of Defense, 1980). The qualitative probability level or the quantitative criticality number and severity are then compiled in a ...

92

Reliability Study On Automotive Component Using Design Failure Mode And Effect Analysis

Reliability Study On Automotive Component Using Design Failure Mode And Effect Analysis

... FMEA technique is applied to analyze the possible failures, in order to raise the safety factor and consequently customer satisfaction. One of the main differences between FMEA and other quality methods is that FMEA is ...

24

Failure mode Effect Analysis of Rollers in Mill Stand

Failure mode Effect Analysis of Rollers in Mill Stand

... potential failure mode before the product is released for production for design, or for process before it leaves the production ...item failure mode are, the severity of its failure ...

7

Failure Mode and Effects Analysis Using Data
 Envelopment Analysis

Failure Mode and Effects Analysis Using Data Envelopment Analysis

... Eq.(2.5) defines the risk of each failure mode as the weighted sum of m risk factors, whereas Eq.(2.6) as the weighted product of m risk factors. For convenience to distinguish between the two risks, we ...

15

RAM analysis of crude oil transfer pumps using dominant failure mode

RAM analysis of crude oil transfer pumps using dominant failure mode

... five failure modes were treated individually in Weibull++ ...the failure modes fitted well into 2-parameter Weibull distribution, while the time to repair for all of the failure modes followed the ...

5

A Need to Modify the Method of Failure Mode and Effect Analysis (FMEA) and Risk Management

A Need to Modify the Method of Failure Mode and Effect Analysis (FMEA) and Risk Management

... with failure mode analysis, the impact of each failure and identified every critical point of ...each failure rating would be based on the most critical and possible failure ...identify ...

16

Detection of Failure mode of Pressure Vessel Agitator due to variable load

Detection of Failure mode of Pressure Vessel Agitator due to variable load

... ________________________________________________________________________________________________________ Abstract-In this era, mixing is one of the most fundamental operations in industries like paper, food, cosmetic, ...

6

Mechanical Failure Mode Causes of In-Wheel Motors

Mechanical Failure Mode Causes of In-Wheel Motors

... mechanical failure mode causes for direct driven electric in-wheel ...for failure causes and ...electrical failure modes, neglecting structural causes and effects which in some cases ...of ...

12

A Failure Mode Evaluation of a 480V MCC in Nuclear Power Plants at the Seismic Events

A Failure Mode Evaluation of a 480V MCC in Nuclear Power Plants at the Seismic Events

... In this study, a seismic behavior of electric cabinet system in Nuclear Power Plants was evaluated by shaking table. A 480V Motor Control Centers (MCCs) was selected for shaking table test and a real MCC cabinet for ...

8

Modeling of failure mode in knee ligaments depending on the strain rate

Modeling of failure mode in knee ligaments depending on the strain rate

... Schenck et al. investigated two "clinically applicable" stain rates, 100 and 5400 %/sec to study human ACL and PCL hyperextension. In the PCL, ligament tearing occurred at the lower stain rate, where as bone ...

8

Failure-mode-hierarchy-based design for reinforced concrete structures

Failure-mode-hierarchy-based design for reinforced concrete structures

... Innovations in concrete construction can be held back by the inability of codes of practice to accommodate new materials. The current design and safety philosophy (DSP) of reinforced concrete relies heavily on the ...

23

Reproducing Failure Mode and Life Prediction of Expansion Joint Using Field Data

Reproducing Failure Mode and Life Prediction of Expansion Joint Using Field Data

... Abstract: In this study, among plant equipment, valve and piping fitting which is vulnerable to waterhammer was selected for diagnosis. Impulsive vibration by waterhammer was measured and applied to HIL simulator as ...

5

Show all 9620 documents...

Related subjects